Sei sulla pagina 1di 7

PVC INSULATED LOW VOLTAGE CABLES

1 - PVC insulated single wires according to VDE 0250 type NYA, BS 6004 & IEC
227.

Conductor Annealed copper conductors - Rigid, stranded.


Size 1 to 800 mm².
Insulation PVC rated 70°C.
Colors Black, red, brown, blue, yellow, green, green-
yellow, white, orange or any other.
Rated 450/750 Volts.
Voltage
Application Equipment wiring, lighting fittings, distribution
in conduits.
Packing 100 yards, 100-meter coils or any other.

2 - PVC insulated single wires, according to VDE 0250 type NYAF, BSS 6500
450/750 V & IEC 227.

Conductor Annealed copper conductors - flexible.


Size 0.5 to 800 mm².
Insulation PVC rated 70°C.
Colors Black, red, brown, blue, yellow and green,
etc….
Application Suitable for inside appliances & in lighting
fittings. Not suitable for wet or damp
location or out doors.
Packing 100 yards, 100-meter coils or any other.

P.O.Box 962716 Amman 11196 – Jordan Tel/Fax: +962 6 55 333 25 www.scawa.com


3 - PVC insulated flexible cords according to VDE 0250/3.69 TYPE NYZ.

Conductor Two or three core 0.5, 0.75 and 1


mm², flexible copper.
Insulation PVC rated 70°C.
Application For connecting light portable
appliances such as lamps, TV
sets, table fans.
Packing 100 yards, 100-meter coils or any
other.

4 - PVC insulated & PVC sheathed Flat Cables. According to VDE 0250 type NYIFY.

Conductor Annealed copper conductors.


Insulation PVC rated for 70°C.
Assembly The cores are laid side by side
with web and covered with PVC-
Sheathing.
Application For wiring in dry conditions for
permanent laying on plaster and
under plaster.
Packing In 100 yards, 100-meter coils or
any other.

P.O.Box 962716 Amman 11196 – Jordan Tel/Fax: +962 6 55 333 25 www.scawa.com


5 - PVC insulated and sheathed two, three, four and five core flexible cords.

According to VDE 0250 Type NYLHY & NYMHY, BS 6500,IEC 227 450/750 V.

Conductor Annealed bunched copper, wires,


flexible.
Size 0.5 to 70 mm².
Insulation Colored PVC, rated for 70°C.
Sheath PVC sheath Wt., Bk., etc...
Rated 300/500 Volts.
Voltage
Application In domestic premises, kitchens,
offices, house hold appliances.
Packing In coil and on drums.

6 -PVC insulated and sheathed two, three and four core cable, Type NYM
According to VDE 0250.

Conductor Annealed copper conductors.


Insulation Colored PVC rated for 70°C.
Lay -up Cores laid up in PVC compound, formed
in circular section.
Sheath Black, white or gray PVC rated for
70°C.
Application In dry and damp rooms over and under
plaster, Burying not allowed.
Packing In coil or on wooden drums.

P.O.Box 962716 Amman 11196 – Jordan Tel/Fax: +962 6 55 333 25 www.scawa.com


7 - PVC insulated and sheathed Single and Multi-core power cables.

According to VDE 0271 type NYY-J and NYY-O, IEC 502. 0.6 /1KV.

Conductor Single or stranded bare annealed copper


wires.
Insulation Colored PVC rated for 70°C.
Lay -up Cores laid up in PVC compound.
Sheath Black PVC rated for 70°C.
Application In buildings and ducts as well as in air, in
ground with
mechanical protection to withstand damage
if needed.
Packing On wooden drums.

P.O.Box 962716 Amman 11196 – Jordan Tel/Fax: +962 6 55 333 25 www.scawa.com


8 - PVC insulated and sheathed Multi-core armored cables.

According to VDE 0271 type NYRGbY and NYFGbY, IEC 502 0.6 /1KV.

Conductor Single or stranded bare annealed copper or


Aluminum Wires.
Insulation Colored PVC rated for 70°C.
Armoring Have round galvanized steel wires with
NYRGbY opposite lay of galvanized steel tape.
Armoring Have flat galvanized steel wires with
NYFGbY opposite lay of galvanized steel tape.
Sheath Black PVC rated for 70°C
Application Underground installations for pull strength.
Packing On wooden drums.

9 - PVC insulated cable-NYCY According to VDE 0271.

Conductor Single or stranded bare annealed


copper wires.
Insulation Colored PVC rated for 70°C.
Bedding Extruded PVC.
Shielding Concentric conductor of copper wires.
Sheath Black PVC rated for 70°C.
Application Underground, outdoors.

P.O.Box 962716 Amman 11196 – Jordan Tel/Fax: +962 6 55 333 25 www.scawa.com


10 - PVC insulated and sheathed armored with steel tapes NYBY

According to VDE 0271 0.6 /1KV.

Conductor Single or stranded bare annealed


copper wires.
Insulation Colored PVC rated for 70°C.
Assembly Cores are twisted together, and
covered with extruded PVC Or lapped
with PVC tapes.
Armoring With steel tape.
Sheathing Black PVC rated for 70°C.
Application Underground installation for pull
strength.

11 - PVC insulated and sheathed flat twin and three core cables

According to BSS 6004, IEC 227 300/500 V.

Conductor Bare annealed solid or stranded copper


wires.
Insulation PVC rated for 70°C.
Sheathing PVC gray color rated for 70°C.
Application Indoor wiring in walls, on boards, and in
channels or embedded in plaster.
Packing In 100 yards coils or any other.

P.O.Box 962716 Amman 11196 – Jordan Tel/Fax: +962 6 55 333 25 www.scawa.com


12 - PVC insulated and sheathed multi-core unarmored cables
PVC/PVC According to BS 6004 and BS 6346 0.6/1KV.

Conductor Single or stranded bare annealed


wires.
Insulation Colored PVC Core insulation rated for
70°C.
Bedding Extruded PVC bedding.
Sheathing Black PVC outer sheath, rated for
70°C.
Application General use.
Packing On wooden drums.

13 - PVC insulated and sheathed single and multi-core steel wire armored cables.

PVC/SWA/PVC According to BS 6346 0.6/1KV, IEC 502.

Conductor Single or stranded annealed wires.


Insulation Colored PVC rated for 70°C.
Bedding Extruded PVC.
Sheathing Black PVC rated for 70°C.
Armoring Single layer of galvanized steel wires
for Multi-Core cables and Single
Aluminiun wires for Single Core cables
Application Underground installation.
Packing On wooden drums.

P.O.Box 962716 Amman 11196 – Jordan Tel/Fax: +962 6 55 333 25 www.scawa.com

Potrebbero piacerti anche