It is probably easier to use the Navisphere GUI to configure the Clariion but below are some of
the CLI commands that can be used to configure the SAN. There is also a procedure generator
which is very usefull called clarproc.exe which can be found on the www.emc.com web site
Raid Groups
example: navicli -h fc4700 createrg 16 0_0_0 0_0_1 0_0_2 -rm yes -pri
high
Creating a raid group
rgID = decimal raid group id
0_0_0 = bus_enclosure_disk
rm = delete raid group when last LUN is unbound
pri = expansion / defragmentation priority
navicli -h <san> chgrg rgID <options>
example: navicli -h fc4700 chgrg 16 -expand 0_0_4 0_0_5 -lex yes -pri
expanding a raid group
high
example: navicli -h fc4700 bind r5 3 -rg 0 -rc 1 -wc 1 -sq mb -cap 250
Storage Groups
Cache Configuration
get cache information navicli -h fc4700 getcache
navicli -h fc4700 setcache -wsza 550 -rsza 100 -wszb 100 -rszb 100
wsza = SPA write cache in MB
rsza = SPA read cache in MB
wszb = SPB write cache in MB
Configure the cache rszb = SPB read cache in MB
p = page size (2, 4, 8 or 16)
l = low watermark
h = high watermark
wc/rc = disable/enable read/write cache
wca/rca = disable/enable read/write SPA cache