Environmental Engineering Systems

E d u c a t i o n a l Tr a i n i n g E q u i p m e n t f o r t h e 2 1 s t C e n t u r y Bulletin 673A

H-6730
Environmental Control Trainer
Purpose
The Hampden Model H-6730 Environmental  Thermometers: Wet and dry bulb ther-  Thermostatic Expansion Valve: Features
Control Trainer has been designed to teach the mometers (one each) that are used to deter- an external pressure equalizer.
fundamental principles of room air conditioning. mine the relative humidity of the recirculated  Axial Fan: Delivers up to 1500 scfm (708
The unit has sufficient capacity to air condition room air. The bulbs are located in the return slps) of air at 1" WC (250 Pa) and incorpo-
an entire room with control over the tempera- air duct and the indicators are on the front of rates a ½ hp variable speed motor.
ture, humidity and air movement. The refriger- the bench.
ant used is HFC-134a. This unit will allow the students to perform the
 Humidity Controller: Two proportional following experiments:
control elements which are room mountable
Description and control the humidity level from 30 to  Heating air to determine the change in com-
The Hampden Model H-6730 Environmental 80% RH. The units are adjustable to any fort due to the change in relative humidity.
Control Trainer utilizes a direct expansion coil, point over this range. One controls the
 Cooling air to determine the changes in
refrigerant-to-air heat exchanger. This heat humidifier and the other cools the heat
comfort due to the condensation of water
exchanger is located in a lighted duct with a exchanger (dehumidifier).
vapor.
transparent top so that students can observe  Humidifier: A spinning drum type unit
water vapor condensing on the heat exchanger  Effect of mixing two air streams on the
which is mounted in the delivery duct. Unit
face. Condensed water vapor is collected in a operating conditions to maintain the same
capacity is 15 Gal/day (2.3 kg/h) and is
drain under the unit. The recirculated room air space.
electrically operated with proportional speed
is mixed with up to 30% outside air and is setting via thermal feedback.  Conduct a heat balance on the heat
moved by an axial flow fan. The air flow rate is exchanger and heating elements.
set by a variable speed fan control.  Electronic Controls: Complete control sys-
tem to allow the student to maintain the air  Determining the domains of comfort or dis-
The instrumentation includes the following: conditioned space subject to external load comfort in the controlled space by manipu-
conditions and unit capacity: lating the:
 Flowmeter: Rotameter which is calibrated a) Temperature
a) Outside Air - 0 to 30% of total regulated
in ml/s at 20°C and features a borosilicate b) Relative Humidity
by electronically controlled louvres. The
glass tube with a stainless steel float. c) Air Movement
student has control over the primary
 Pitot Tube: A pitot-static probe used in and secondary temperature sensors
conjunction with an inclined manometer to (recirculated and outside air) which This unit is supplied with a comprehensive
measure the air flow velocities at various serve as the signals to determine the technical manual.
duct locations. heating or cooling requirements.
The entire unit is mounted on a stationary
 Digital Temperature Meter: A precision bench constructed of square mechanical tubing
b) Relative Humidity - 30-80% RH
unit which displays the output of the and faced with 14 gauge sheet metal panels.
regulated by a proportional band
Chromel/Alumel (type T) thermocouples in The overall dimensions of the unit are 68"H x
humidity controller.
use on the unit. There is a thermocouple 70"W x 36"D (1727mm x 1778mm x 914mm).
selector switch which allows the user to dis- c) Dry Bulb Temperature - 50° to 90°F
play any of the 10 thermocouples supplied (10° to 32°C) room air temperature.
with the unit.
Services Required
d) Solid State Zone Load Analyzer -
 208VAC-3φ- 50/60Hz
 Thermocouples: A pair of type T thermo- controls the fans, louvres and
couples are located at the expansion coil humidifier to maintain the room at
inlet and outlet. The average temperature of the present conditions.
the air across the expansion coil is moni-  Air Heater: Electrical air heating elements
tored by a pair of averaging thermocouples at 600W.
composed of four type T thermocouples
connected in parallel. Plus four more ther-
mocouples placed in crutial areas.
All Hampden units are available for operation at any voltage or frequency

072303

P.O. Box 563, East Longmeadow, MA 01028 • Tel 413-525-3981 • Fax 413-525-4741 • E-mail sales@hampden.com 800-253-2133