Sei sulla pagina 1di 8

Data Sheet

Vmux-2100
Voice Trunking Gateway

• Unique TDMoIP multiplexing, together with various voice compression algorithms,


provides up to 16:1 compression for effective bandwidth utilization
• Fully transparent to signaling and telephony features
• Automatic link backup mechanism between TDM and Ethernet links ensures system
Efficiently survivability

transmitting up to 16 • HDLC channel compression for CCS protocols


• Compact 1U-high platform, compatible with 19-inch racks
E1 or T1 voice trunks
over a single E1/T1, Vmux-2100 is a modular Voice Trunking Switching transmission between TDM and
Gateway that compresses and transports IP links does not require additional
serial, or IP link up to 16 E1 or T1 voice trunks over E1, T1,
n x 64 kbps serial, or IP links.
investments in equipment, and can be
performed automatically upon link failure.
Vmux-2100 employs G.723.1, G.729 Voice Activity Detection (VAD) and silence
Annex A and G.711 compression suppression allow Vmux units to
algorithms, together with RAD’s unique dynamically allocate bandwidth for voice
TDMoIP multiplexing, to transmit up to traffic. This results in very efficient
496/384 voice channels, including bandwidth usage, allowing more
transparent CAS and CCS, over a single bandwidth for data transport. The
E1/T1, n x 64 kbps serial or IP link. gateway detects, generates and relays
Vmux-2100 is unique in that it is a single DTMF/MFR2/MFC signaling.
device that can transmit compressed voice
over both TDM and IP networks and can
easily switch between them whenever this
may be advantageous or when there is a
link failure.

Pulse, Inc. - www.pulsewan.com Toll Free: 1-888-785-7393 - Int'l: 1-951-694-1173 wireless@pulsewan.com


Vmux-2100
Voice Trunking Gateway

CAS is transparently transmitted DATA STREAM TRANSFER CONTROL MODULE


end-to-end (see Figure 6). Vmux-2100 transfers the following data The Control module features a single
When transmitting over non-IP networks streams that are not processed as voice: 10/100BaseT UTP Ethernet port with
(E1, T1 or n x 64 kbps), the A2oMPLS Multiple HDLC channels – Vmux-2100 optional auto-negotiation support. The
multiplexing format can be used instead of supports up to four independent HDLC Ethernet port operates at 10/100 Mbps
TDMoIP. The A2oMPLS header is smaller data streams per E1/T1. Each data stream speed, half and full duplex. The Ethernet
than the TDMoIP header, saving a further may occupy one or more timeslots. All CCS interface complies with the IEEE 802.3
5% in bandwidth. This technique is protocols, such as SS7, ISDN and QSIG, are standard. It supports full auto-negotiation
compliant with the MPLS/Frame Relay supported. according to 802.3x flow control for full
Alliance 5.0 Implementation Agreement: duplex, and backpressure option for half
SS7 channels – Vmux-2100 supports up to duplex.
I.366.2 Voice Trunking Format over MPLS.
two independent SS7 data streams per
Vmux-2100 supports relay of Group III fax, E1/T1. Each data stream may occupy one In addition to the standard Ethernet port,
as well as all common modem rates and or more timeslots. the Control module can also be ordered
standards. Alternative modem and fax can with a redundant pair of E1, T1 or
Transparent channels – Vmux-2100 n x 64 kbps serial links.
be transmitted transparently (voice band
supports transparent connection between
data).
n x 64 channels over IP and TDM ENHANCED LINK BACKUP
Only 1U-high, Vmux-2100 is a compact networks. This feature operates between
modular unit that can be installed in two Vmux-2100 units as well as between Vmux-2100 features automatic link backup
19” racks. The unit consists of up to four Vmux-2100 and Vmux-110. Up to between the TDM ports and the Ethernet
Voice Compression modules, a single 8 timeslots per E1/T1 can carry port on the Control module (in
Control module, and up to two power transparent data. point-to-point applications only). Primary,
supply modules. All modules are plug-in secondary and tertiary links are configured
and field-replaceable. Power supply and so that if the primary link fails, Vmux-2100
Voice Compression modules are automatically switches to the next link.
hot-swappable. Once a failed higher link has been
restored, the voice traffic is automatically
switched back.

Figure 1. Voice Trunking over IP in an Any-to-Any Point Topology


Data Sheet

VOICE COMPRESSION MODULES BUNDLE CONNECTIVITY CHECK SUPER TANDEM


Each Vmux-2100 Voice Compression Vmux-2100 checks voice bundle In super tandem applications (see
module features two or four E1/T1 ports. connectivity using either TDMoIP Layer-4 Figure 3), where calls are routed through
Timeslots received from the PBX E1/T1 messages or traditional ICMP (pings). With several Vmux-2100 gateways, the
trunks are compressed by the modules, routers or firewalls that might discard intermediate Vmux-2100 gateways sense
using standard algorithms and silence pings, and thus prevent Vmux-2100 from that the voice has already been
suppression. The compressed payload passing bundles through, the Layer-4 compressed by another Vmux, and thus do
bytes are then encapsulated into a method is recommended. This method is not uncompress and then recompress the
TDMoIP packet and forwarded to the main also preferred since it avoids flooding the data as it passes through them. This
link. network with pings. feature ensures that voice is compressed
and decompressed only once (at the
CHANNELIZED E1/T1 MAIN LINK Q.50 & BANDWIDTH MANAGEMENT terminating Vmux-2100 gateways)
MODULES Vmux-2100 employs two types of avoiding voice degradation or delay.
Instead of one of the voice modules, bandwidth management methods. The
Vmux-2100 can be equipped with a Q.50 protocol can be used with PBXs that QoS SUPPORT
two-port or four-port channelized E1/T1 support it. The proprietary Vmux-2100 The Vmux-2100 IP port complies with all
main link module. With this module, bandwidth control can be used when the the relevant Ethernet LAN standards, such
Vmux-2100 supports up to four E1 or T1 Q.50 protocol is not supported. as IEEE 802.3 and 802.3u. It provides
ports for point-to-multipoint TDM Bandwidth management is available only reliable, high Quality of Service (QoS), by
applications (see Figure 2). when using link ports on the control optional VLAN tagging and priority labeling
module (not on the channelized module). according to IEEE 802.1D&Q.

Figure 2. Vmux-2100 with a Channelized E1/T1 Module at the Central Site in Point-to-Multipoint Topology Transporting Data and
Compressed Voice over a TDM Network
Vmux-2100
Voice Trunking Gateway

The user can configure the Type of Service Since Vmux-2100 internal control unit has DIAGNOSTICS
(ToS) of the outgoing IP packets. This its own IP address, the Ethernet port can Vmux-2100 supports local (internal) and
allows an en-route Layer 3 router or also be used for connecting to remote (external) loopback activation on
switch that supports ToS (or Diffserv), to management systems running over E1/T1 links. The user can also perform
give higher priority to Vmux-2100 IP traffic Ethernet networks. Management systems tone injection towards the local PBX. In
for delay-sensitive applications. connected to one unit’s Ethernet port can addition, a ping utility is included to
An assigned, IANA-registered UDP socket also manage a remote unit, inband (see confirm IP connectivity to remote units.
number for TDMoIP packets simplifies flow Figure 4).
Main Links
classification through switches and The LAN traffic connected to the Ethernet IP Diagnostics:
routers. port can be inhibited to prevent LAN data Performance monitoring
bursts from monopolizing the TDM link LAN statistics
MANAGEMENT bandwidth and disrupting voice traffic. Pings
All Vmux-2100 operating parameters are This ensures that the link bandwidth will
E1/T1 Diagnostics: local and remote
configured using simple, menu-based be utilized for voice (and optionally
loopbacks
software. For upgrades or backup, management) traffic only.
software can be uploaded and For system security, Vmux-2100 provides Voice Compression Ports
downloaded via TFTP. four different levels of users: Monitor, Local and remote loopback, per E1/T1
Technician, Operator and Administrator. channel
Vmux-2100 can be configured and
Up to 20 different usernames with Tone injection towards local side: Per
monitored via a local ASCII terminal, Telnet
passwords can be defined. timeslot, per entire E1/T1 channel, or
or via RADview, RAD’s network
on all E1/T1 channels simultaneously
management system. Vmux-2100 features
a DB-9 Control port for direct connection Channelized E1/T1 Main Link Module
of a local terminal for monitoring and Local and remote loopbacks per E1/T1 link
control.

Figure 3. Super Tandem Application with no Voice Degradation or Delay between Hops: Calls between Site B and Site C are
Compressed/Decompressed only Once
Data Sheet

Connectors (per port) Interface


Specifications RJ-45 for balanced interface Selectable for V.35, X.21, RS-530,
RS-530A, V.36/RS-449, or RS-232
CONTROL MODULE – ETHERNET PORT Note: CBL-RJ45/2BNC/E1 adapter cable is available
for converting each Control module E1 port RJ-45 Connector
Note: The Control Module includes a single Ethernet
connector into a pair of BNC connectors for Both ports terminate in a single 50-pin
port by default. A redundant pair of E1, T1 or Serial
unbalanced coax interface (see Ordering). SCSI connector
links can be added as an option.
Note: A Y-cable can be ordered for splitting the
Number of ports CONTROL MODULE – T1 LINK
serial links’ single 50-pin SCSI connector into two
1
Number of Ports separate channels with standard V.35, X.21 or
Standards 2 (one active, other for backup) RS-530 connectors (see Ordering).
IEEE 802.3, 802.3u, Ethernet, 802.1D&Q
Statistics
CONTROL PORT
Data Rate Full statistical diagnostics capability
10 or 100 Mbps, half duplex or full duplex, according to ANSI T1.403-1989 Located on the Control module, for direct
auto-negotiation Local support of ESF diagnostics according connection to terminal.
to AT&T PUB 54016 Standards
Statistics
According to RFC 2819, RMON-MIB Note: Additional E1/T1 interface specifications that RS-232/V.24 (DCE)
are applicable to main links, voice ports and
Copper UTP Interface Data Rate
channelized ports are listed under General.
Range: up to 100m (330 ft) on UTP Cat.5 9.6, 19.2, 38.4, 57.6, or 115.2 kbps
cable CONTROL MODULE – SERIAL LINK Connector
Connector: RJ-45 DB-9, female
Indicators: Number of Ports
• ACT (green) – blinks when traffic is 2 (one active, other for backup)
VOICE COMPRESSION MODULES
detected over the Ethernet line Data Rate
• LINK (green) – ON when Ethernet line Compression Algorithms
n x 64 kbps, up to 2048 kbps
is OK G.723.1 (5.3 or 6.4 kbps)
Clock Modes G.729A (8 kbps)
CONTROL MODULE – E1 LINK DCE: Vmux-2100 provides clock to G.711 (A-law or μ-law)
connected equipment
Number of Ports Silence Suppression
DTE: Vmux-2100 accepts clock from
2 (one active, other for backup) G.723.1A, G.729B
connected equipment

Figure 4. Management of a Remote Vmux-2100 Inband from an Ethernet LAN via a TDM Link
Vmux-2100
Voice Trunking Gateway

Echo Cancellation E1 INTERFACES Standards


32 msec per channel as per G.168 ANSI T1.403, AT&T TR-62411,
Data Rate
ITU-T Rec. G.703
Fax Relay 2.048 Mbps (per port)
Group III, 4.8, 9.6, 14.4 kbps Framing
Standards
SF, ESF
Modem Relay ITU-T Rec. G.703, G.704, G.706, G.732,
V.22/V.22 bis G.823 Line Code
V.32/V.32 bis AMI
Framing
V.34 up to 21.6 kbps
G.732N Zero Suppression
Voice Band Data G.732N with CRC-4 B8ZS
Transparent support for modems and G.732S
Receive Signal Level
faxes G.732S with CRC-4
With CSU: 0 to -36 dB
Signaling Support Line Code Without CSU: 0 to -30 dB
Transparent CAS, including R2 and E&M HDB3
Transmit Signal Level
Transparent CCS, including ISDN, QSIG and Receive Signal Level With CSU: 0, -7.5, -15, or -22.5 dB
SS7 With LTU: 0 to -43 dB Without CSU: ±2.7V (±10%) at 0-655 ft
Clear channel Without LTU: 0 to -12 dB
Timing
MF Signaling Support Transmit Signal Level Internal or loopback
DTMF, MFR2, MFC detection, generation Balanced: ±3V (±10%)
and relay Unbalanced: ±2.37V (±10%) (for Control Jitter Performance
module only) Per AT&T TR-62411
Ports per Module
(according to ordering) Timing Line Type
E1 Port Modules: Internal or loopback Balanced 4-wire, 100Ω
2 (62 channels max) or
Jitter Performance Indicators (per port)
4 (124 channels max)
Per ITU-T G.823 RED (red): Local Sync Loss (Red Alarm) on
T1 Port Modules:
port
2 (48 channels max) or Line Type YEL (yellow): Remote Sync Loss (Yellow
4 (96 channels max) Balanced 4-wire, 120Ω Alarm) on port

CHANNELIZED E1/T1 MAIN LINK Indicators (per port) Connectors (per port)
MODULES LOC (red): Local Sync Loss on port RJ-45
REM (red): Remote Sync Loss on port
Ports per Module
Connectors (per port) GENERAL
(according to ordering)
E1 Port Modules: RJ-45 for balanced interface E1/T1 Alarms (per port)
2 (62 channels max) or LOS – Loss of Signal
4 (124 channels max) T1 INTERFACES LOF – Loss of Frame
T1 Port Modules: Data Rate AIS – Alarm Indication Signal
2 (48 channels max) or 1.544 Mbps (per port) RAI – Remote Alarm Indication
4 (96 channels max) LOMF (E1 only) – Loss of Multiframe
LCV – Line Code Violation

Figure 5. Vmux-2100 Transporting up to 496/384 Voice Channels over a Single TDM Link
Data Sheet

Vmux-2100 Panel Indicators Power Physical


TST (yellow): Input (according to ordering): Height: 4.3 cm (1.7 in)
• On: test is running AC: 100 to 240 VAC, 50/60 Hz Width: 43.5 cm (17.1 in)
• Flashes: Sync loss is detected on the 48: -48 (-36 to -72) VDC Depth: 24.0 cm (9.5 in)
TDM uplink (if TDM Line Check feature 24: 24 (20 to 36) VDC Weight: 7.0 kg (15.5 lb)
is enabled) Output (per PS module):
Environment
ALM (red): alarm is present in system 3.3 VDC: up to 15A
Temperature:
PWR 1 (green): On when Power Supply 5 VDC: up to 5A
Operating: 0 to 50°C (32 to 122°F)
Module 1 is providing power Total: 60W
Storage: -20 to 70°C (-4 to 158°F)
PWR 2 (green): On when Power Supply Note: Two hot-swappable power supply modules Humidity: Up to 90%, non-condensing
Module 2 is providing power can be installed for redundancy

Figure 6. Compressed Voice over IP, Including Transparent Transmission of CCS and CAS

Table 1. Vmux/Gmux Family Comparison

Feature Vmux-2100 Vmux-110 Vmux-210 Gmux-2000


Maximum 16:1 16:1 16:1 16:1
compression ratio
Maximum number of 496 30 30 3,472
compressed voice
channels
Voice Interface E1/T1 E1/T1/FXS/FXO/E&M FXS E1/STM-1
Network Interface E1/T1, Serial, Fast E1/T1, Serial, Fast Ethernet E1/T1, Serial, Fast Ethernet E1, STM-1, GBE
Ethernet
Modularity 3 3
Signaling Any Any CAS only Any
Fax/Modem/DTMF 3 3 3 3
Relay
Management ASCII terminal, Telnet, ASCII terminal, Telnet, Web, ASCII terminal, Telnet, Web, ASCII terminal, Telnet,
Web*, RADview-SC/Vmux RADview-SC/Vmux RADview-SC/Vmux Web, RADview-SC/Vmux*

* - Unavailable yet
Data Sheet
Vmux-2100
Voice Trunking Gateway

164-100-07/07 Specifications are subject to change without prior notice. © 2003–2007 RAD Data Communications Ltd. All other trademarks are the property of their respective holders.
VMUX-M/VCA-&/% OPTIONAL ACCESSORIES
Ordering Enhanced Voice Compression Module CBL-VM2100/?
Vmux-2100/*/$
VMUX-M/ML/&/% Serial link adapter Y-cable to split the
Note: System includes chassis, power supplies and Channelized E1/T1 Main Link Module 50-pin SCSI into two link connectors
power supply cables only. A Control Module and at
Legend Legend
least one Voice Compression Module must be
& TDM interface type ? Interface type and clock mode:
ordered for every Vmux-2100 system. All modules
E1 E1 ports V35/DCE V.35, DCE mode
can be ordered separately.
T1 T1 ports V35/DTE V.35, DTE mode
Legend % Number of E1/T1 ports X21/DCE X.21, DCE mode
* Power supply type: 2 2 ports X21/DTE X.21, DTE mode
AC 100 to 240 VAC 4 4 ports 530/DCE RS-530, DCE mode
48 -36 to -72 VDC 530/DTE RS-530, DTE mode
VMUX-2100-PS/*
24 20 to 36 VDC
Power Supply Module CBL-RJ45/2BNC/E1
$ Redundant power supply:
Interface adapter cable for converting one
R Redundant power supply (of
Control module E1 port RJ-45 connector
same type) SUPPLIED ACCESSORIES
into a pair of BNC connectors for
AC power cord (with AC power supply unbalanced coax interface
MODULES only)
Note: For E1 Voice Modules and Channelized E1
VMUX-M/M-ETH-# DC adapter plug (with DC power supply
Modules, conversion to unbalanced 75Ω interfaces
Control Module with single Ethernet port only)
must be performed externally (e.g., using RAD’s
by default, and optional redundant E1, T1,
CBL-D89F-D89M-STR BE-1).
or serial links
Control port cable RM-VMUX-2100/23
Legend
RM-VMUX-2100/19 Hardware kit for mounting one
# Optional redundant TDM link
Hardware kit for mounting one Vmux-2100 unit into a 23-inch rack
E1 E1 link
Vmux-2100 unit into a 19-inch rack
T1 T1 link
SERIAL_LINK Serial link
(Default is Ethernet port
only)

Pulse, Inc. - www.pulsewan.com Toll Free: 1-888-785-7393 - Int'l: 1-951-694-1173 wireless@pulsewan.com