Sei sulla pagina 1di 1

R

Diesel
Level
Control
Relays

DLC D1 *DLC D2
DLC D2
D91 Series D91 Series

Application Best suitable for monitoring single level overflow / dry run alarm in Best suitable for monitoring two levels the Diesel FuelTank &
the Diesel FuelTank. Multiple Relays can be used with independent automatically operate the fuel pump or solenoid valve for
functions as described above in the same tank. Applications with reffilling purpose. Multiple Relays can be used with independent
Diesel Fuel tanks of Diesel Powered Generators, Boilers, Screw functions as described above in the same tank. Applications with
compressors, Fire Fighting Pumps etc. Diesel Fuel tanks of Diesel Powered Generators, Boilers, Screw
compressors ,Fire Fighting Pumps etc.
Function The DLCD1 relay operates by sensing the continuity of Infra The DLCD2 relay operates by sensing the continuity of Infra Red
Red optical signal through the Transmitter & Receiver of the Fork optical signal through the Transmitter & Receiver of the Fork
Type Prod Sensor tip. Type Prod Sensor tip. Two Fork Type Sensor FRKP 1 are required
Single Fork Type Sensor FRKP 1 is required to sense the fuel level. to sense the fuel level. This sensor is mounted either from TOP or
This sensor is mounted either from TOP or SIDE wall on the fuel tank, SIDE wall on the fuel tank, with its End Tip immersed in
with its End Tip immersed in the fuel tank at the desired position. the fuel tank at the desired position. The Relay energizes when both
The Relay energizes when Sensor tip is inside the liquid & is Sensor tips are inside the liquid & de-energizes when level drops
de-energizes when level drops below sensor. below both the sensors.
Operation Timing Diagram
Aux. ~ Aux. ~
Supply Supply
Diesel Fuel Level Diesel Fuel Level

13 14 13 14

13 15 13 15

Technical Specifications
Aux. Supply 110 / 220 / 230 / 240 / 380 / 415 /440 V AC +/- 20% , 110 / 220 / 230 / 240 / 380 / 415 /440 V AC +/- 20% ,
50 / 60 Hz +/-3%, 24 V DC +/- 10% 50 / 60 Hz +/-3%, 24 V DC +/- 10%
Power Consumption 3 VA 3 VA
Input Sensors 1 No Minilec Sensor Prod FRK P1 2 Nos Minilec Sensor Prod FRK P1
Input Sensitivity NA N. A.
Output 1 CO, Rated 5A / 230V AC (Resistive) 1 CO, Rated 5A / 230V AC (Resistive)
Settings & Indications Trip & Reset Level Trip Time Delay LEDs Trip & Reset Level Trip Time Delay LEDs
Healthy According to Sensor Less than 1 Sec. According Sensor Less than 1 Sec.
Position Position
Temperature - 5 o C to 55 o C - 5 o C to 55 o C
Humidity Upto 95% Rh Up to 95% Rh
Dimensions & Weight
Relay 30.5 x 75 x 117.5mm (300 gm) 56.5 x 75 x 117.5mm (400 gm)
Sensor Electrode 16 x 75 (L) (100 gm) 16 x 75 (L) (100 gm)
Terminal Connections M1 M1
---
R R -
---
M2 M2
------
Y Y
M3 M3 --
-
B MOTOR B --- - MOTOR

OFF OFF ON
ON
N V N V
DOL STARTER DOL STARTER
CAT No.: GC012 / DLC

AUX.
AUX. SUPPLY
SUPPLY
3 CORE
3 CORE CABLE
CABLE P1

Ordering Information
v Product Family Name P2
v Model Name DIESEL TANK
v Auxiliary Supply Voltage SENSOR PROD
DIESEL TANK
SENSOR PROD * Model to be discontinued shortly
Minilec (India) Pvt. Ltd. Mutha Road, Pirangoot, 412 111, Pune (India) TEL : (020) 2922162 / 2922354-57,