Resumen
Abstract
Was based on a methodology proposed, it wasn´t referenced in literature, but that was based in polarity of
taurine to change the taurine in its sodium salt. The treatment basified energy drink (Pike) to a pH near to nine
to ionize molecule of taurine ensuring that in saline state was more akin to aqueous phase or polar but don´t in
organic phase. Was performed a curve of relation between pH versus absorbance respect to taurine achieving
that pH of 8,87 the absorbance was 0,004± ppp, doing that interference ceased to absorb. To changes of pH,
the caffeine produced a minimum can be associated a change from one state to another, while alkaloid reaches
ionic form due to its higher distribution constant in dichloromethane (Kd=4,8) [1]. To pH slightly above
neutrality (7,17) the caffeine presents major absorbane and remains constant at least to more basic states, that
means caffeine reaches major number of unsaturations favoring a highest reading of signal. With the objective
to accept or reject the null hypothesis (H0: Quantification of caffeine in Pike discarding presence of taurine)
by conversion of taurine in its sodium salt, was performed thin layer chromathography or TLC to characterize
caffeine and taurine, prove presence since caffeine as taurine in problem sample but this latter also, contained
in extraction solvent, creating ambiguity about H0 because it is rejected for contamination or it is uncertain for
the same reason.
Figura 1
O 5. Conclusión
posible.
NO2 O
En cuanto al porcentaje de recuperación, este
fue calculado en base a la concentración final Y es producto de la reacción de sustitución
obtenida en la extracción, en relación con el nucleofílica del 2,4-dinitrofluorobenceno por
valor teórico por extraer de la bebida (Ver el grupo amino libre de la taurina. Esta sería
anexo 8.5). Sin embargo se trata de un una prueba útil, además de TLC para
porcentaje (30,12%) significativamente confirmación del aminoácido por absorción a
incierto porque la desviación está asociada a la 360 nm, en solvente y muestra problema.
posible saturación del solvente con cafeína y También se podría emplear como una forma
otras sustancias, y a la recuperación del de derivatización de taurina antes del
método que no logró ser cuantificada por tratamiento de extracción.
errores propios y que por tanto se hallan como
incertidumbre NO determinada. 7. Referencias
[1] A. Guarnizo, P. Martinez, Experimentos de [6] M. Aranda G. Morlock, Simultaneous
química orgánica con enfoque en ciencias de determination of riboflavin, pyridoxine,
la vida, Ediciones Elizcom, Pág. 76-81 nicotinamida, caffeine and taurina in energy
Colombia. drinks by planar chromatography-multiple
detection with confirmation by electrospray
[2] E. A. Abourashed, J. S. Mossa, HPTLC ionization mass spectrometry, Institute of
determination of caffeine in stimulant herbal Food Chemistry, University of Hohenhemim,
products and power drinks, Departamento de Germany.
Pharmacognocy, College de Pharmacy, King
Saud University, Saudi Arabia. [6] R.T. Morrison, R. M. Boyd, New York
University, Química Orgánica, 5ta Edición,
[3] AOAC Official Method 999.12 Taurine in Pearson Educación, Pág. 1336-1337, México.
Pet Food.
[7] B. Uribe Ortega, N. Montes Beneitez, Ma.
[4] Y. Sawabe, T. Tagami, K. Yamasaki, J. Quintana, Instituto Nacional de Seguridad e
Determination of Taurine in Energy Drinks by Higiene en el Trabajo, Determinación de la
HPLC Using a Precolumn-Derivative, Osaka incertidumbre de medida de agentes químicos,
Prefectural Institute of Public Health, Japan. Edita Instituto Nacional de Seguridad e
[5] D. Skoog, F. Holler, T, Nieman, Principios Higiene en el Trabajo, Pág. 5, Madrid.
de Análisis Instrumental, 5ta Edición,
McGrawHill, Pág 355-356, Madrid.
8. Anexos
Si la indicación del fabricante es que la pureza es igual al 99%, la incertidumbre se calcularía así:
(1,00-0,99), y si es mayor del 99%, se calcularía como (1-0,99)/12.
8.2 Datos de las medidas de masa y volumen para reactivos y material volumétrico.
Masa Masa Cafeína Masa Cafeína Volumen Balón Volumen Balón Pipeta 1,0 Pipeta 0,5
patrón(g) dope(g) 10mL 25mL mL mL
Bicarbonato
(g)
n=3; % Recuperación teórico=80; Volumen extractante 11-12 mL; Volumen de muestra = 80 mL;
Volumen de dopado de 10 mL de 100 ppm
Dope inefectivo, debido a que se manejo una concentración inadecuada que ocasionó la dilución en
vez de la concentración.
Rf= dR/dM
Rf experimental = 3/3,2=0,94
Rf experimental = 1,6/1,9=0,84
La diferencia en los Rf puede deberse a: Distinta saturación del vapor del disolvente entre una placa
y otra, calidad de la placa (diferentes soportes, aluminio y vidrio), aplicación de la muestra.
Rf teórico = 0,59
Aunque la taurina según evidencia experimental y contrastado con la literatura sobre su solubilidad en
solventes polares, no es soluble en diclorometano, presenta una solubilidad parcial en pequeñas cantidades
(menos de 10 mg/L) sobre el extractante, de manera que para aislar en definitiva la presencia de taurina y
comprobar su actividad a diferentes grados de acidez