Sei sulla pagina 1di 3

123.

FREYSSINET C AND K SYSTEMS ANCHORAGES

K System : Anchorage A’ (Tromplate)

H1 C

pitch Ø
a

Ø5
Ø2

Ø1
D1
Ø3

Ø4
n=
Ø

F b/2 one layer b/4


3b/8 two layers

B
q = 25 Ø + S

Type 1
overall

Ø4 Ø3
n=

Ø/2 6Ø 6Ø S 6Ø 6Ø Ø/2

q = 25 Ø + S
E

Type 2
q1 = 16 Ø + S
overall

E Ø/2 7.5Ø S 7.5Ø Ø/2

q1 = 16 Ø + S

PAGE 1/3
PPC 123/13-02.95
123. FREYSSINET C AND K SYSTEMS ANCHORAGES

K System
ANCHORAGE A’ (TROMPLATE) / ANCHORAGE A (PLATE + TRUMPET)
ANCHORAGE

A’–7 K 13 A’–12 K 13 A’–19 K 13 A’–27 K 13 A–37 K 13 A–55 K 13


Dimensions in mm
A’–4 K 15 A’–7 K 15 A’–12 K 15 A’–19 K 15 A–27 K 15 A–37 K 15
AxB 170 x 170 235 x 220 260 x 260 315 x 315 450 x 400 495 x 495
C 120 180 205 400 470 486
b1 75 70
D1 120 140 162 218 252 320
H1 50 55 63 65 78 95
(4) Ø1int. x e Class 1 55 x 0.30 65 x 0.30 80 x 0.35 100 x 0.40 120 x 0.60 130 x 0.60
SHEATH - GROUTING

(4) Ø1int. x e Class 2 55 x 0.45 65 x 0.45 80 x 0.50 100 x 0.60 120 x 0.60 130 x 0.60
(1) K 13 Cement (kg/m) 2.55 3.30 4.80 7.95 11.70 12.15
K 13 Grout (l/m) 1.70 2.20 3.20 5.30 7.80 8.10
(1) K 15 Cement (kg/m) 2.70 3.45 4.95 7.80 11.25 12.15
K 15 Grout (l/m) 1.80 2.30 3.30 5.20 7.50 8.10
Ø2 G 3/4’’ G 3/4’’ G 3/4’’ G 1’’ G 1’’1/2 G 1’’1/2
E 220 270 300 370 590 620
F 110 120 125 125 145 160
CACHETAGE -

a (°) 10 10 10 10 30 30
FIXING

Ø3 190 254 300 352 440 440


Ø4 12 12 12 16 20 20
n= 2 4 4 4 4 4
(2) Whorl Ø
10 12 14 16 18 20
HELICAL BURSTING
REINFORCEMENT

Steel grade FeE 235


Number of convolutions 6 6 6 6 7 8
Ø5 ext. 200 280 360 440 540 640
Pitch 50 50 60 65 70 70
Total length 300 300 360 390 490 560
(2) Type of cross-wise
1 or 2 1 or 2 1 or 2 1 or 2 1 or 2 1 or 2
bursting reinforcement
CROSS-WISE BURSTING
REINFORCEMENT

Number of layers 1 1 1 1 2 2
Ø of reinf. bars Steel grade FeE 235 10 12 14 16 14 16
b 160 200 240 300 360 400
s 100 120 150 170 210 240
q1 350 420 500 570 560 640
q2 260 312 374 426 434 496
(3) Jack K 100+ K 200+ K 350+ K 500+ K 700+ K 1000+
or or or or
Multistrand K 100 BH⊗ K 200 BH⊗ K 350 BH⊗ K 500 F ⊗
TENSIONING

Pull-in (mm)
K 13 + = 6 to 9 + = 6 to 9 + = 6 to 9 + = 6 to 9 + = 6 to 9 + = 6 to 9
⊗ = 4 to 6 ⊗ = 4 to 6 ⊗ = 4 to 6
K 15 + = 6 to 11 + = 6 to 11 + = 6 to 11 + = 6 to 11 + = 6 to 11 + = 6 to 11
⊗ = 4 to 8 ⊗ = 4 to 8 ⊗ = 4 to 8 ⊗ = 4 to 8

NOTE
(1) The theoretical quantities must be increased by 10 to 40 % depending on the number of grouting phases.
(2) The helical or cross-wise bursting reinforcing bars given in the table, which oppose the bursting force in the concrete of the anchorage zone, are only valid for an isolated anchorage
in a prismatic section piece (test block), for concrete with a strength fcmin between 23 and 43 MPa (cylinder strength).
– When the anchorages are grouped into one of several lines, continuous reinforcement with an equivalent cross-sectional area must be provided to link all the anchorages, appropriately
anchored within the structure.
(3) All the jacks given in the table correspond to optimal use.
(4) (complying with standard) EN 523.

PAGE 2/3
123. FREYSSINET C AND K SYSTEMS ANCHORAGES

K System : Anchorage A (Plate + Trumpet)

a
Ø pitch

Ø5
Ø2

Ø1
D1
Ø3

h
H1 b/2 one layer b/4
F 3b/8 two layers C
q = 25 Ø + S

Type 1
overall

Ø4 B Ø3
n=4

Ø/2 6Ø 6Ø S 6Ø 6Ø Ø/2

q = 25 Ø + S
E

Type 2
q1 = 16 Ø + S
overall

E
Ø/2 7.5Ø S 7.5Ø Ø/2

q1 = 16 Ø + S

PAGE 3/3

Potrebbero piacerti anche