3,000,000 MTBF
1.36 M 1.79 M
2,000,000 MTBF
1.0 M
• •
1,000,000 MTBF •
1985
•
1989 1990 1992 1993 1994 1995 1996
First 750 kVA, 180 Advanced battery Intro of Series 600; Industry-best Power-Tie introduced. First UPS product Introduction of IGBT 1100 kVA rating.
cell module introduced; status monitoring robust PWM SCR 1000 kVA UPS. First practical use of family to hit and exceed models — first large Improved AC and
auxiliary-commutated developed; first inverter; digital Full 0.9 load pf fiber optics in UPS to 1,000,000 hours critical model IGBT-based UPS DC capacitor reliability.
inverter; no module true high-current controls; industry- product family. provide system-to- bus field-documented models without need
output switch required. 3 ph continuous first ASIC; first system signal fault MTBF. Static Transfer to parallel devices.
duty static bypass agency-listed isolation. Switch (STS) introduced. Major size reduction.
switch in one large UPS
package.
No-Compromise Reliability In
High Power Applications
There are certain operations and processes in this world that are so critical to the
existence of a business, institution, government agency or other
organization...that even the mere thought of them shutting down due to a power
failure is unthinkable.
It is at this point that a solution is required that leaves no room for failure, no room
for compromise of any kind — a solution that actually goes beyond "High 9's"
reliability. This is when to turn to a Liebert Series 610 UPS system.
2.12 M 2.22 M
2.57 M
• • • • •
1.87 M
• •
•
regulated power
output at full voltage 200
The fault handling capabilities of the Liebert Series 610 — at every point of the
104 %
especially when used in multi-module installations — are overload/ time curve. 100
designed to keep the critical load on the UPS, no matter
what the condition of the incoming power.
40ms 1s 30s 10 min.
Time
A fault is managed in this order of priority:
The overload handling characteristics of the Series 610 are also enhanced
Single Module System Multi-Module System
through the use of pulse-parallel operation. When an overload condition, such
First priority First priority
Manage an internal fault Manage an internal fault as magnetic inrush current or a branch load circuit fault, exceeds 155% of the
within the UPS module within the UPS module full load current rating, the static bypass switch pulses on. This allows up to
without the critical bus without the critical bus
exceeding voltage limits exceeding voltage limits 1000% rated full load current from the bypass line to clear the overload without
and without transfer and without transfer
to bypass. to bypass.
a full transfer to bypass, while keeping your critical load operations still
connected to the UPS inverter.
Second priority Second priority
If the fault or overcurrent If the fault cannot be The bypass source is in parallel with the UPS output, permitting the bypass
cannot be handled handled internally to the
internally by the module, module and redundant source to carry the initial overload current. If the overload clears, a complete
then transfer the critical modules are present, load transfer to bypass is not made. If the overload condition exceeds the
bus to the bypass source disconnect that module
without exceeding from the critical inverter capacity, the automatic transfer is completed, maintaining the load
voltage limits. bus without exceeding
voltage limits and without
voltage within specified limits. The use of pulsed static switch operation provides
transfer to bypass. a simple, reliable response to brief output bus dynamic overload conditions and
Third priority reduces nuisance transfer/retransfer cycles for short-term conditions. Not all
If fault or overcurrent
cannot be handled by the UPSs use motor-operated current breakers for this function. Liebert does.
remaining modules on-line,
then transfer the critical Digital Control Accuracy
bus to the bypass source
without exceeding The reliability and performance of the Liebert Series 610 UPS is enhanced
voltage limits.
through the use of digital control and Application-Specific Integrated Circuits
(ASICs) for key control logic functions. These computer-tested controls provide self
diagnostics and greatly reduce the parts count and number of interconnect points.
What's the "real world" performance standard you expect
from your power protection? Protecting the operation of the
critical bus no matter what.
The Liebert Series 610 will meet your highest output Other features include:
performance expectations. This includes the ability to •Connected Load Compatibility — The Liebert Series
handle both balanced and unbalanced loads, high crest 610 supports all normally-expected load configurations
factor loads, dynamic loads and overloads, as well as both and performance characteristics without the need for
external and internal faults. special provisions.
Proven Advantages That Have Made The •Smaller Footprint — All of the Series 610 models have
5
Liebert Series 610 The Standard Of Reliability an exceptionally small footprint, even those with input
The Liebert Series 610 continues to meet all industry isolation transformers. In some cases, two Liebert UPS
performance standards for large, high-reliability UPS modules can be installed in the space formerly required
systems with the most robust inverter in the industry. by just one competitive unit.
It can manage overloads and faults without the need for a •Higher DC Bus Utilization — Provides higher AC/AC and
static switch on the UPS inverter output. It can handle DC/AC efficiency and allows a relatively smaller battery.
dynamic loading and non-linear loads. The Series 610 also •High Performance PWM Inverter — The most robust
costs less to operate thanks to >93% operating efficiency inverter in the industry, it meets all industry performance
and a leading power factor of greater than 0.92 for all units standards with the lowest parts count. Handles most
Bypass
AC Input
Output
Isolation System
Technology Designed For Bypass
6 Rectifier Inverter Transformer
Breaker Critical Bus
Reliability Rectifier AC Output
AC Input UPS Output
Thanks to digital controls and a CBI
Breaker
unique inverter topology, the Liebert
Series 610 can be used in all of the
Battery
conventional single-bus system
configurations: single module,
parallel-redundant or isolated Multi-Module Configuration AC Input
redundant.
Source
In addition, the Series 610 is The need for maximum reliability has driven customers to
Battery
uniquely well suited for high- add redundant UPS modules to their critical power systems.
availability, multi-module system Multi First, a redundant UPS module improves maintainability
System System
Module
configurations and for configurations Units
since one UPS moduleBypass
at a time can be taken
Controloff-line for
Cabinet
using Load Bus Sync™ (LBS) and Breaker
service without shutting down the whole system. Second,
Static Switcha
Multi-Module System
AC Input
Source
Battery
Multi
System System
Module
Bypass Control
Units
Cabinet
Breaker
Battery
Static Switch
10
LOAD AC INPUT/ %EFFICIENCY AT NOMINAL BATTERY MAXIMUM HEAT DIMENSIONS APPROXIMATE
UPS RATING POWER OUTPUT VARIOUS LOADS1 REQUIREMENTS DISSIPATION (BTU/HR) WxDxH2 (INCHES) WEIGHT 2
KVA KW FACTOR VOLTAGE 50% 75% 100% (CELLS) FULL LOAD TOP ENTRY ONLY TOP & BOTTOM ENTRY SMS MMU
65 52 0.8 480/480 92.5% 93.5% 93.5% 240 12,350 N/A 34X32X68 1,500 1,470
65 52 0.8 480/208 92.5% 93.0% 93.0% 240 13,350 N/A 34X32X68 1,700 1,670
65 52 0.8 208/208 92.0% 92.0% 92.0% 240 15,450 N/A 34X32X68 1,900 1,870
80 64 0.8 480/480 92.5% 93.5% 93.5% 240 15,200 N/A 34X32X68 1,700 1,670
80 64 0.8 480/208 92.5% 93.0% 93.0% 240 16,450 N/A 34X32X68 1,950 1,920
80 64 0.8 208/208 92.0% 92.0% 92.0% 240 19,000 N/A 34X32X68 2,100 2,070
100 80 0.8 480/480 92.5% 93.5% 93.5% 240 19,000 48X33X78 56X33X78 2,500 2,465
100 80 0.8 480/208 92.5% 93.0% 93.0% 240 20,550 48X33X78 56X33X78 2,800 2,765
100 80 0.8 208/208 92.0% 92.0% 92.0% 240 23,750 48X33X78 56X33X78 3,100 3,065
125 100 0.8 480/480 92.5% 93.5% 93.5% 240 23,750 48X33X78 56X33X78 2,600 2,565
125 100 0.8 480/208 92.5% 93.0% 93.0% 240 25,700 48X33X78 56X33X78 2,900 2,865
125 100 0.8 208/208 92.0% 92.0% 92.0% 240 29,700 48X33X78 56X33X78 3,250 3,215
150 120 0.8 480/480 93.0% 94.0% 94.0% 240 26,150 48X33X78 56X33X78 2,850 2,800
150 120 0.8 480/208 93.0% 93.5% 93.5% 240 28,450 N/A 56X33X78 3,050 3,000
150 120 0.8 208/208 93.0% 92.5% 92.5% 240 33,200 N/A 56X33X78 3,320 3,270
225 180 0.8 480/480 93.0% 94.0% 94.0% 240 39,200 48X33X78 56X33X78 3,190 3,140
225 180 0.8 480/208 93.0% 93.5% 93.5% 240 42,700 N/A 56X33X78 3,475 3,425
225 180 0.8 208/208 93.0% 92.5% 92.5% 240 49,800 N/A 56X33X78 3,870 3,820
300 240 0.8 480/480 93.0% 94.0% 94.0% 240 52,300 N/A 72X35X78 4,200 4,150
300 240 0.8 480/208 93.0% 93.5% 93.5% 240 56,950 N/A 72X35X78 4,450 4,400
300 240 0.8 208/208 93.0% 92.5% 92.5% 240 66,400 N/A 72X35X78 5,400 5,350
400 320 0.8 480/480 93.0% 94.0% 94.0% 240 69,700 N/A 72X35X78 4,900 4,850
400 320 0.8 480/208 93.0% 93.5% 93.5% 240 75,950 N/A 72X35X78 5,150 5,100
400 320 0.8 208/208 92.5% 92.0% 92.0% 240 94,950 N/A 96X35X78 8,400 8,350
400 360 0.9 480/480 93.0% 94.0% 94.0% 240 78,450 N/A 72X35X78 5,100 5,050
450 360 0.8 480/480 93.0% 94.0% 94.0% 240 78,450 N/A 72X35X78 5,100 5,050
500 (6P) 400 0.8 480/480 93.0% 94.0% 94.0% 240 87,150 N/A 72X39X78 5,775 5,710
500 (12P) 400 0.8 480/480 92.5% 93.0% 93.0% 240 94,910 N/A 96X39X78 8775 8710
500 (6P) 450 0.9 480/480 93.0% 94.0% 94.0% 240 98,050 N/A 72X39X78 5,795 5,730
500 (12P) 450 0.9 480/480 92.5% 93.0% 93.0% 240 106,770 N/A 96X39X78 8795 8730
625 (6P) 500 0.8 480/480 93.5% 94.5% 94.5% 240 99,300 N/A 108X39X78 7,500 7,405
625 (12P) 500 0.8 480/480 93.0% 93.5% 93.5% 240 118,650 N/A 120X39X78 10,580 10,485
750 (6P) 600 0.8 480/480 93.5% 94.5% 94.5% 240 119,200 N/A 108X39X78 8,100 8,005
750 (12P) 600 0.8 480/480 93.0% 93.5% 93.5% 240 142,350 N/A 120X39X78 11,580 11,485
750 (12P) 675 0.9 480/480 93.0% 93.5% 93.5% 240 160,150 N/A 120X39X78 11,880 11,785
1000 (12P)3 900 0.9 480/480 92.5% 93% 93% 240 231, 200 N/A 177X44X82 16,700 16,555
1 Efficiency measured at rated load power factor and non-linear load without input filter. Input filter loss is less than 0.5%.
2 Dimensions and weights do not include System Control Cabinet furnished with Multi-Module Systems. Weights are for the standard configurations; top-entry
models will be 200 pounds less.
3 1000 kVA unit is SCR-based inverter. See also separate 1000 kVA Series 610 brochure.
Specifications
See separate brochure for 1000 kVA
No organization in the world today has a better understanding of exactly what it takes to keep critical L I E B E R T CO R P O R AT I O N
1050 DEARBORN DRIVE
information and industrial processes operating continuously than Liebert. P.O. BOX 29186
COLUMBUS, OHIO 43229
It starts with your local Liebert Representative, Distributor or Reseller. We are the only 800.877.9222 PHONE (U.S. &
CANADA ONLY)
company in this business that maintains such a strong local presence on a national and 614.888.0246 PHONE (OUTSIDE U.S.)
international basis. This resource, coupled with our broad product line, gives Liebert the ability 614.841.6022 FAX
to create a "tailored solution" that will meet your protection needs precisely and efficiently.
VIA LEONARDO DA VINCI 8
ZONA INDUSTRIALE TOGNANA
With your purchase of a Liebert product, you are buying into a company that stands behind its 35028 PIOVE DI SACCO (PD)
products. You are also aligning yourself with an organization that has a reputation for quality ITALY
39 049 9719 111 PHONE
and reliability that is second to none. 39 049 5841 257 FAX
In the systems protection business it's when you need someone to count on that you find out EMERSON NETWORK POWER ASIA PACIFIC
whether you’ve made the right choice. Liebert customers — many of them with us for over three 7/F., DAH SING FINANCIAL CENTRE
108 GLOUCESTER RD, WANCHAI
decades — already know how good their decision was. HONG KONG
852 25722201 PHONE
852 28029250 FAX
24 X 7 TECH SUPPORT
800 222 5877 PHONE
614 841 6755 (OUTSIDE U.S.)
No matter where your needs for Due to continuing product improvement, specification are subject
to change without notice. Liebert Corporation assumes no
protecting the infrastructure of responsibility, and disclaims all liability for damages resulting
from use of this information or for any errors or omissions.
your facility are heading — Liebert
© 2004 Liebert Corporation. All rights reserved throughout
is the one source that can deliver the world. Specifications subject to change without notice.
the high-availability solution. All names referred to are trademarks or registered trademarks
of their respective owners.
® Liebert and the Liebert logo are registered trademarks
of the Liebert Corporation.
® Keeping Business in Business is a registered trademark
of the Liebert Corporation.
The Emerson logo is a trademark and service mark
of Emerson Electric Co.
SL-30500 (2/04)
Printed in USA
That Is
The Liebert Experience