Sei sulla pagina 1di 1

SAUDI ARAMCO ID/PID - 18-MAY-05 - REV 0 (Standards Cutoff - August 2004)

SAIC NUMBER DATE APPROVED QR NUMBER


SAUDI ARAMCO INSPECTION CHECKLIST
Ceramic Wall and Floor Tiles and Accessories Receiving and
SAIC-M-1041 18-May-05 CIVIL-
Storage Inspection
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.

LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.

SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?

SAUDI ARAMCO INSPECTION LEVEL CONTRACTOR INSPECTION LEVEL

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

A Ceramic Floor Tiles, Trim & Materials Receiving

All wall tile and ceramic tile shall be shipped sealed with the grade SAES-M-100
A1
conformance label on the shipping container. (ANSI A137.1, Sec. 9.3.1) Sec. 801.1

A maximum of 5 defective tiles out of every 80 received shall permit


acceptance of any lot of tiles; 6 or more defective tiles out of 80 shall be SAES-M-100
A2
the basis for rejection of the entire lot of tiles delivered. Sec. 801.1
(ANSI A137.1 Sec. 4.5.1.1)

First grade tile shall meet the requirement of no surface defects when
SAES-M-100
A3 viewed at 3 feet; Second grade shall meet the requirement viewed from
Sec. 801.1
10 feet. (ANSI A137.1 Sec. 9.2.2)

Each container of adhesives or grout shall be labeled with the date of


SAES-M-100
A4 manufacture and the age after which the material shall not be used.
Sec. 801.1
(ANSI A118.6H-5.1.1.3)

Each container of adhesives or grout shall come with instructions for


SAES-M-100
A5 proper use with various kinds of tile, recommended tools and procedures
Sec. 801.1
for application shall be given. (ANSI A118.6H-5.1.1.2)

B Ceramic Floor Tiles, Wall Tiles, Trim Materials, Grout/Mortar Storage

Store and handle materials in a manner to prevent damage or SAES-M-100


B1
contamination by water, freezing or foreign matter. (ANSI A108.1A-1.3) Sec. 801.1

REMARKS:

REFERENCE DOCUMENTS:
1- SAES-M-100 -- Saudi Aramco Building Code, 29 January 2003

Contractor / Third-Party Saudi Aramco


Construction Representative* PMT Representative
Work is Complete and Ready for Inspection: T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Inspector PID Representative


Performed Inspection Work / Rework May Proceed T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Supervisor Proponent and Others


Quality Record Approved: T&I Witnessed QC Record Reviewed Work Verified
Name, Organization,
Name, Sign and Date:
Initials and Date:
*Person Responsible for Completion of Quality Work / Test Y = YES N = NO F = FAILED

Page 1 of 1