REVISION HISTORY
Stage Responsib
Description of Activity Controlling Document Acceptance Criteria Frequency Quality Record S-C GGS O/ E
No le Party
- 80 degrees operation
temperature
Incoming
Incoming Material Acceptance - 3 layer high density hot melt Const./
1 Material test certificate Each Batch material control H R R
Heat Shrinkable Sleeves system QAC
report
- 3 mm coating thickness on weld
system
Visual inspection
- Any disbondment of HDPE pipe
coating shall be
2 Surface condition before blasting DISI-QA-PR-G-HQ-031 QAC Each joint Site report H I R
repaired/removed
- Maximum chamfer angle is 30
degrees from surface
1 per 10
3 Surface condition after blasting ISO 8502-9 Salt content max. 20 mg/m2 QAC Site report H I R
Joints
4 Environmental conditions ISO 8502 Humidity < 85 % QAC Each Joint Site report H I R
5 Pipe temperature before blasting ISO 8502 Minimum 3 ºC above the dew point QAC Each Joint Site report H I R
Abbreviation: S : Surveillance, R : Check Review, W : Witness Inspection, H : Hold Inspection, I : Inspection , QAC: QA/QC Department , WxR: Witness Random, IxR: Inspection Random
S-C : Subcontractor, A : Approve
Stage Responsib
Description of Activity Controlling Document Acceptance Criteria Frequency Quality Record S-C GGS O/ E
No le Party
Abbreviation: S : Surveillance, R : Check Review, W : Witness Inspection, H : Hold Inspection, I : Inspection , QAC: QA/QC Department , WxR: Witness Random, IxR: Inspection Random
S-C : Subcontractor, A : Approve
Stage Responsib
Description of Activity Controlling Document Acceptance Criteria Frequency Quality Record S-C GGS O/ E
No le Party
17 Weld bead tape application DISI-QA-PR-G-HQ-031 Compliance to APS QAC Each Joint Site report H I R
EN 12068 & Min. 0.5 N/mm. at 23 ± 2 ºC. (30/50/HT) For Every 100
22 Peel strength to pipe surface QAC ……. H I R
TABLE 1/ANNEX C Min. 0.05 N/mm. at Tmax (--/50/HT) Joints
EN 12068 & Min. 0.4 N/mm. at 23 ± 2 ºC. (30/50/HT) For Every 100
23 Peel strength to factory coating QAC ……. H I R
TABLE 1/ANNEX C Min. 0.04 N/mm. at Tmax (--/50/HT) Joints