Capacitance type Level Indicator


Capacitance type Level Indicators / Switch / Transmitters are suitably used for monitoring and
controlling of liquid levels in tanks or vessels. No moving parts ensure no wear and tear. These level
Indicators / Switches are suitable for a wide variety of applications having a fixed dielectric constant

Features:

• Microprocessor based Control Unit circuit


• Software Calibration (by 4 nos. push button
switches, inside top cover) of
9 Range - Digital Indication of level in mm, ft,
Mtrs, % etc
9 Decimal Point Setting
9 Alarm Lo & Hi Set Points
9 Alarm Directions – Lo or Hi
9 Time Delay – 0 – 10 seconds to tackle
turbulence
9 4 - 20 mA o/p, into a max load of 600 Ω
9 RS 232C Compatible output proportional to
level
• Up to 4 independent set points in single unit
• Set points adjustable throughout the range
(without altering liquid level)
• HART output (Integral Transmitter Model)
• Wide range of Probe design to suit a wide variety
of applications
• Available in integral / non integral models
• Wide separation distance of 500 meters between
Probe and Control Units

Applications:

Water
Acids
Alkalis
Oils
Chemicals

Principle of Operation:
As media rises and falls in the vessel, the amount of capacitance developed between the
sensing probe and the ground (vessel wall or reference probe in case of non-metallic vessels)
also rises and falls. This change of capacitance is converted into a current signal by the preamplifier.
The pre- amplifier output is connected to the Control Unit. The Amplifier, in the Control Unit converts
the pre amplifier signal into a proportional voltage, which is amplified and fed to the Microcontroller
Circuitry, which in turn drives the indication circuit LED, relay circuit and the transmitter circuit.
Specifications:

Materials of construction: Probe: SS304/ SS316–PVC/PP/PVDF/ECTFE/PTFE/PFA insulated


Reference Probe: SS304/ SS316 bare or insulated with Hastelloy tip
Flanges: CS/ SS304/ SS316-ECTFE coated/ PVC/PP
Enclosures: Powder coated / Epoxy painted Aluminum / DMC
Enclosure protection: IP66
Mounting: Vertical / Horizontal
Measuring Range: 15M (max), for flexible probes / 2M (max) for rigid probes.
Process Connection: 2" flange / 1½” NPT screwed / other types on request
Temperature Rating: 250° C (max), please contact us for higher temperatures.
Pressure Rating: 25 kg/ cm² (max), please contact us for higher pressures.
Power Supply: 230V AC / 110V AC, ± 10%, 50 Hz / 24V DC ± 10%
Output Relays: SPDT (1NO + 1NC) / DPDT (2NO + 2NC)
Relay Contact Rating: Up to 6A, 230V AC / 6A, 24 VDC
Output: 4-20 mA, 600 Ω
Time Delay: 0-10 seconds as standard
Accuracy/ Repeatability: ± 1% / ± 0.5% of full scale
Power Consumption: 14V A (max)
Cable Entry: ½" NPT (F) as standard, optional cable glands/plug & socket connectors

Model Number decoding system:

Probe Unit –

LCP
Special
/ Enclosure Type of Process Probe Output Indication
Features,
LCPI design Conn. type t
S

1. Standard 1. Non integral 1. Screwed 1. Flexible 1. Dedicated 1. NA Cooling fins,


3. IP:66/67 3. Integral 2. Flanged 4. Rigid current o/p 3. Digital P&S conn.
5. FLP 2. 4-20 mA, 5. Analog
2w, HART
3. 4-20 mA,
2 wire
4. 4-20 mA,
4 wire
5. 1 set point
6. 2 set point
7. No o/p

Control Unit –

LC Enclosure Mounting Indication Output Set points Switch Special


type
Features,
S

1. Standard 1. Panel 1. Digital 1. No o/p 1. NA 1. 1 SPDT Zener Barrier,


3. IP 66 2. Wall 3. NA 3. 4-20 mA 3. 1 sp 3. 1 DPDT P&S conn.
5. FLP 5. Universal 5. Analog 5. 2 sp 5. 2 SPDT
7. 3 sp 7. 2 DPDT
9. 4 sp 0. NA

Note:
All combinations are not possible
Since improvements are made from time to time, specifications are liable to change without notice

Tech. Pub.: LC/CP/006/R-1 dt. 01/11/2009