GE Consumer & Industrial GE Consumer & Industrial

32764
Power Protection Power Protection

GE Consumer & Industrial


Control and Automation
Power Protection (formerly GE Power Controls),
a division of GE Consumer & Industrial,
is a first class European supplier of
low-voltage products including wiring
devices, residential and industrial electrical
distribution components, automation
products, enclosures and switchboards.
Demand for the company’s products
For industrial applications
comes from, wholesalers, installers,
panel-board builders, contractors, OEMs Everything is under control
and utilities worldwide.
www.gepowercontrols.com

Control and Automation


GE POWER CONTROLS
International Sales
Nieuwevaart 51
B-9000 Gent
Belgium
Tel. +32/9 265 21 11
Fax +32/9 265 28 90
E-mail: gepcbel@gepc.ge.com

GE POWER CONTROLS
Hornhouse Lane
Knowsley Industrial Park
Liverpool L33 7YQ
United Kingdom
Tel. 0800/587 1251
Fax 0800/587 1239
E-mail: gepcuk@gepc.ge.com

GE imagination at work GE imagination at work


680804
Ref. C/4506/E/EX 16.0 Ed. 07/05
© Copyright GE Power Controls 2005
Control and Automation

Plug-in relays and Auxiliary contactors A

Motor protection devices B

Contactors and Thermal overload relays C

Motorstarters D

Control and signalling units E

Electronic relays F

Limit switches G

Speed drive units H

Main switches I

Numerical index X
Control and Automation
A C D
Auxiliary contactors and Contactors and Motorstarters
Plug-in relays Thermal overload relays

Series PRC - Plug-in relays Series M - Minicontactors Coordination


Miniature plug-in relays 3 and 4P (4NO, 2NO+2NC, Link modules for mechanical
Standard 8-11 pin plug-in 4NC) 6,9 and 12A (AC-3) and electrical connection of
relays 20A (AC-1) the manual motor starter
Control circuit AC and DC and the M/CL contactor
ranges
! A.2 ! C.2
! D.2
Series M - Auxiliary minicontactors Series CL - Contactors
lth = 16A 3 and 4P (4NO, 2NO+2NC)
Direct-on-line starters
Extended index

9 to 105A (AC-3) 25 to 140A Series M: 6 to 12A (AC-3)


(AC-1) AC, DC and with Series CL: 9 to 105A (AC-3)
electronic module Series CK: 150 to 825A (AC-3)
! A.16 ! C.10
! D.18
Series RL - Auxiliary contactors Series CK - Contactors
lth = 20A 3 and 4P (4NO) 150 to 825A Reversing starters
(AC-3) 200 to 1250A (AC-1) Series M: 6 to 12A (AC-3)
AC, DC and with electronic Series CL: 9 to 105A (AC-3)
module Series CK: 150 to 825A (AC-3)
! A.22 ! C.18
! D.20
Series MTO - Thermal overload relays
For minicontactors series M Star-delta starters
B from 0.11 to 14A Series CL
Series CK
Motor protection devices
! C.60
! D.22
Series SFK -
Series RT - Thermal overload relays
Motor protection circuit breaker For contactors series CL and ASTAT S - Soft starter
Thermal and magnetic pro- CK from 0.16 to 850A Small soft starter with
tection of AC and DC motors Class 10A, 10, 20, 30 integral by-pass
Setting ranges from 0.1
to 25A
! C.62
! B.2 ! D.66
Series CSC -
Surion - Manual motor starter ASTAT SD - Soft starter
Thermal and magnetic pro-
Contactors for capacitors switching
Soft starter for 3ph AC mo-
tection - Magnetic protection tors up to 850 kW
Setting ranges from 0.1
to 63A
! B.8 ! D.72
! C.74

Series 390.R - Clapper contactors ASTATplus - Soft starter


Solid state soft starter for
3ph AC motors up to 850 kW

! C.80 ! D.78

2
Control and Automation
E F
Control and signalling units Electronic relays
Series P9 - Panel mounting -
Units Ø 22 mm Series 101 - Palm push-buttons Series DM - Single voltage relays
22.5mm module
Direct supply voltage
With transformer

! E.10 ! E.82 ! F.3

Series P9 - Base mounting Series IP - Foot switches Series NMV - Multivoltage relays
22.5mm module
Direct supply voltage (24-

Extended index
240V AC/DC)
With transformer
! E.25 ! E.84 ! F.4

Series P9 - Push-button stations Safety foot switches Series D - Single voltage relays
45mm module
Direct supply voltage
With transformer

! E.28 ! E.86 ! F.6

Series P9 - Equipped boxes Series 105 - Signalling devices Liquid level detectors
45 mm module
With transformer
DIN mounting

! E.31 ! E.87 ! F.7

Series P9 - Common accessories Earth leakage relays


45 mm module
Direct supply voltage
With transformer

! E.34 ! F.8

Series 077 - Units Ø 30 mm Protection relays


45 mm module
Direct supply voltage
With transformer

! E.48 ! F.9

Series NLT - Light towers Detection relays


Direct supply voltage
With transformer

! E.76 ! F.10

Control and protection relays

! F.11

3
Control and Automation
G H I
Limit switches Speed drive units Main switches
Series IS and IM VAT20 Series ML - standard programme
Metal and Thermoplastic Single-phase or three-phase Main switches and Emer-
EN 50041 digital inverters for control- gency-stop switches for
Positive opening ling the speed of three- machinery
phase induction AC motors
from 0.2 to 2.2 kW
! G.2 ! I.4
! H.2
Series IUG and IUC Series ML - enclosed switches
Thermoplastic EN 50047 VAT200
Positive opening From 0.4 to 2.2kW at 200V,
single phase power supply
Extended index

From 0.4 to 7.5kW at 200V,


three phase power supply
! G.4 From 0.75 to 11kW at 400V, ! I.7
three phase power supply
Series IZ ! H.8
Thermoplastic miniature
VAT2000
Three phase variable speed
drives for AC motors 220-
! G.6 240V or 380-480V power
source
Series 114FCT 0.4 to 315kW in constant
torque and up to 370kW in
Three pole limit switches variable torque applications
Thermoplastic
Positive opening ! H.14

! G.8 AV300i - Adjustable frequency


flux vector drive
Series 115 - Pressure switches
Bellows type
Piston type

! H.38
! G.16

Safety switches

! G.22

Pull rope switches

! G.26

4
Control and Automation

Also check out our electronic web catalogue !


Go to www.gepowercontrols.com and click on

• Use the Quick search to directly search


on product number or keyword

e-catalogue
• Find a product easily using
“parametric search”, entering the
technical characteristics of the product
you are looking for

• Compare many products next to each


other, looking at common and
comparable features

• Comparable features

• Common features

• Every product page contains all available


data: technical specifications, mounting
instructions, dimensional drawings,
texts for tender...

• Plus another very usefull functionality:


all linked accessories and functions
related to the choosen product

• All product info in one centralised


At your finger tips: an e-catalogue with place on our site
exceptional functionalities driving your • All product info is downloadable,
personal productivity when needing printable and emailable !

product information... • Always the latest up-to-date info at


hand !

5
Everything is
Plug-in relays & Auxiliary contactors

Series PRC - Plug-in relays


A.3 Order codes
A.7 Technical data
A.14 Dimensions

Series M - Auxiliary minicontactors


A.17 Order codes
A.26 Technical data
A.31 Terminal numbering
A.40 Dimensions
Plug-in relays and Auxiliary contactors A

Series RL - Auxiliary contactors


Motor protection devices B
A.23 Order codes
A.34 Technical data
Contactors and Thermal overload relays C
A.36 Terminal numbering
A.42 Dimensions
Motorstarters D

Control and signalling units E

Electronic relays F

Limit switches G

Speed drive units H

Main switches I

Numerical index X

under control A.1


Series PRC
Plug-in auxiliary relays
• AC or DC coils
• Lockable test button with mechanical flag indicator
• Sockets with rear 35mm rail (EN 50022) mounting.

Miniature relays Sockets


Types Poles AC ratings Types
PRC4M2... 2 CO 12A/250V PRCG-ES15/2N

PRC4M3... 3 CO 10A/250V PRCG-ES15/3N

PRC4M4... 4 CO 6A/250V PRCG-ES15/4N


Plug-in relays

Standard 8-11 pin relays Sockets


Types Poles AC ratings Types
PRC2P2... 2 CO 10A/250V PRZ8

PRC3P3... 3 CO 10A/250V PRZ11

Approvals
A According to types: Interface relay module Sockets
Types Poles AC ratings Types
Plug-in relays Sockets
PRC1S1... 1 CO 6A/250V -
CE CE
B CSA CSA
For use with PLC systems
cUR cUR
PRC1T1... 1 CO 16A/250V PRCGZT80
VDE
C PRC1T2... 2 CO 8A/250V PRCGZT80

D
Catalogue number structure
Series No. of contacts
E Standard 8 pin = 2 1
Standard 11 pin = 3 2
Square base miniature = 4 3
Input/output interface relay = 1 4
F Special executions
D = Free wheeling diode (DC only)

G Plug-in relays P R C L

Type Coil voltage


A = 6V
H Standard Pin =
Miniature = M
P
B = 12V
Interface = S - T D = 24V
G = 48V
J = 110V (DC)
I Contact materials
Standard AgNi = 0
J
N
=
=
120V (AC)
230V (AC)
Gold plated cont. 5µ Au = 2
Standard AgSnO2 for Interface relays = 3 Voltage
A = AC
X C = DC
B = AC/DC

Order codes ! pg. A.3


Modules for sockets ! pg. A.6
Technical characteristics ! pg. A.7
Dimensions ! pg. A.14

A.2
Series PRC
Miniature plug-in relays
Ratings Contacts Voltage With LED
Standard material Cat. no. (2) Ref. no. Pack
AC
2 changeover 12A/250V 0 AC 12V PRC4M20ABL 220710 10
contacts AgNi 24V PRC4M20ADL 220711 10
48V PRC4M20AGL 220712 10
120V PRC4M20AJL 220715 10
230V PRC4M20ANL 220717 10
DC 12V PRC4M20CBL 220713 10
24V PRC4M20CDL 220714 10
48V PRC4M20CGL 220716 10
110V PRC4M20CJL 220718 10
DC 12V PRC4M20DCBL 220754 10
Diode 24V PRC4M20DCDL 220755 10
48V PRC4M20DCGL 220756 10
110V PRC4M20DCJL 220757 10

Order codes
3 changeover 10A/250V 0 AC 12V PRC4M30ABL 221051 10
contacts AgNi 24V PRC4M30ADL 221052 10
48V PRC4M30AGL 221053 10
120V PRC4M30AJL 221056 10
230V PRC4M30ANL 221058 10
DC 12V PRC4M30CBL 221054 10
24V PRC4M30CDL 221055 10
48V PRC4M30CGL 221057 10
110V PRC4M30CJL 221059 10
DC 12V PRC4M30DCBL 221074 10
Diode 24V PRC4M30DCDL 221075 10
48V
110V
PRC4M30DCGL
PRC4M30DCJL
221076
221077
10
10
A

B
4 changeover 6A/250V 0 AC 12V PRC4M40ABL 221809 10
contacts AgNi 24V PRC4M40ADL 221810 10
48V PRC4M40AGL 221811 10
120V PRC4M40AJL 221814 10
230V PRC4M40ANL 221816 10 C
DC 12V PRC4M40CBL 221812 10
24V PRC4M40CDL 221813 10
48V PRC4M40CGL 221815 10

DC
110V
12V
PRC4M40CJL
PRC4M40DCBL
221817
221851
10
10 D
Diode 24V PRC4M40DCDL 221852 10
48V PRC4M40DCGL 221853 10
110V PRC4M40DCJL 221854 10
E

Sockets F
Cat. no. Ref. no. Pack

For PRC4M2... Screw terminals Socket PRCG-ES15/2N 220912 10


2 changeover Two levels Fixing clip Metal PRCG1052 220914 10 G
contacts Retainer/Extractor Black plastic PRCMS35 220915 10
Identification plate PRCTR1 220916 10

For PRC4M3... Screw terminals Socket PRCG-ES15/3N 221442 10


3 changeover Two levels Fixing clip Metal PRCG1052 220914 10 I
Retainer/Extractor Black plastic PRCMS35 220915 10
contacts
Identification plate PRCTR1 220916 10

X
Screw terminals Socket PRCG-ES15/4N 221934 10
For PRC4M4... Fixing clip Metal PRCG1052 220914 10
Two levels
4 changeover Retainer/Extractor Black plastic PRCMS35 220915 10
contacts Identification plate PRCTR1 220916 10

A.3
Series PRC
Standard 8-11 pin plug-in relays
Ratings Contacts Voltage With LED
Standard material Cat. no. (2) Ref. no. Pack
AC
Standard 8 pin 2 changeover contacts
10A/250V 0 AC 12V PRC2P20ABL 220019 10
AgNi 24V PRC2P20ADL 220020 10
48V PRC2P20AGL 220021 10
120V PRC2P20AJL 220024 10
230V PRC2P20ANL 220026 10
DC 12V PRC2P20CBL 220022 10
24V PRC2P20CDL 220023 10
48V PRC2P20CGL 220025 10
110V PRC2P20CJL 220027 10
DC 12V PRC2P20DCBL 220041 10
diode 24V PRC2P20DCDL 220042 10
48V PRC2P20DCGL 220043 10
Plug-in relays

110V PRC2P20DCJL 220044 10

Standard 11 pin 3 changeover contacts


10A/250V 0 AC 12V PRC3P30ABL 220310 10
AgNi 24V PRC3P30ADL 220311 10
48V PRC3P30AGL 220312 10
120V PRC3P30AJL 220315 10
230V PRC3P30ANL 220317 10
DC 12V PRC3P30CBL 220313 10
24V PRC3P30CDL 220314 10
48V PRC3P30CGL 220316 10
A DC
110V
12V
PRC3P30CJL
PRC3P30DCBL
220318
220335
10
10
diode 24V PRC3P30DCDL 220336 10
48V PRC3P30DCGL 220337 10
110V PRC3P30DCJL 220338 10
B

C Sockets
Cat. no. Ref. no. Pack

D For PRC2P20...
Standard 8 pin
Screw terminals
One level
Socket
Fixing clip
PRCZ8
PRCPZ11
220216
220218
10
10

Solder terminal Socket PRCG8 220217 10


Fixing clip PRCR159 220219 10
E

For PRC3P30... Socket PRCZ11 220647 10


F Standard 11 pin
Screw terminals
One level Fixing clip PRCPZ11 220218 10

Solder terminal Socket PRCG11 220648 10


Fixing clip PRCR159 220219 10
G

A.4
Series PRC
Interface relay
Ratings Ratings Contacts Voltage With LED
AC1 DC1 material Cat. no. Ref. no. Pack
6,2mm wide
1 single pole 6A/250V - 3 AC/DC 230V PRC1S13BNL 222013 10
AgSnO2

1 changeover 6A/250V - 3 AC 230V PRC1S13ANL 222012 10


contact AgSnO2
DC 12V PRC1S13CBL 222007 10
24V PRC1S13CDL 222008 10

AC/DC 24V PRC1S13BDL 222004 10

Identification label PRCTR1S 222043 10


20-way jumper link PRCW20 222039 10

Order codes
Interface relay for PLC systems
Ratings Ratings Contacts Voltage With LED
AC1 DC1 material Cat. no. Ref. no. Pack

1 changeover 16A/250V 16A/24V 0 AC 24V PRC1T10ADL 221868 10


contact AgNi 120V PRC1T10AJL 221869 10
230V PRC1T10ANL 221870 10

DC 12V PRC1T10CBL 221860 10


24V PRC1T10CDL 221861 10
110V PRC1T10CJL 221862 10 A

2 changeover
contacts
8A/250V 8A/24V 0
AgNi
AC 24V
120V
PRC1T20ADL
PRC1T20AJL
221883
221884
10
10
B
230V PRC1T20ANL 221885 10

DC 12V
24V
PRC1T20CBL
PRC1T20CDL
221875
221876
10
10
C
110V PRC1T20CJL 221877 10

D
Complete set of relay, socket, module (diode+Led for DC-Varistor + Led for AC) and retaining clip + marking plate.
16mm width

Spare parts E
Voltage Cat. no. Ref. no. Pack

Miniature P.C.B. relays. 16A AC 24V


120V
PRCT1AD
PRCT1AJ
221896
221897
20
20
F
1 changeover contact
230V PRCT1AN 221898 20

DC 12V PRCT1CB 221890 20


24V
110V
PRCT1CD
PRCT1CJ
221891
221892
20
20
G
Miniature P.C.B. relays. 8A AC 24V PRCT2AD 221913 20
2 changeover contacts 120V PRCT2AJ 221914 20
230V PRCT2AN 221915 20 H
DC 12V PRCT2CB 221905 20
24V PRCT2CD 221906 20
110V PRCT2CJ 221907 20
I
Socket for miniature Three level screws
PRCGZT80 221918 10
P.C.B. relays

Retainer/Retractor PRCMS16 221920 10 X


Plate PRCTR 221921 10

NOTE: If more than 12A are applied to the relay contact, twin wiring is required.
See the connection diagram of the relay

A.5
Series PRC
Modules for sockets
Color Cat. no. Ref. no. Pack
Led

Diode Protection against polarity inversion

For use with sockets: 6 / 230V DC PRCM21P 222100 10


PRCG-ES15/2N
PRCG-ES15/3N
PRCG-ES15/4N 6 / 230V DC PRCM21N 222101 10

Diode Protection against polarity inversion


and Led Coil energizing indication
Plug-in relays

For use with sockets: 6 / 24V DC Red PRCM31R 222102 10


PRCG-ES15/2N Green PRCM31G 222104 10
PRCG-ES15/3N 24 / 60V DC Red PRCM32R 222103 10
PRCG-ES15/4N Green PRCM32G 222105 10
PRCGZT80 110 / 230V DC Red PRCM33R 222109 10
Green PRCM33G 222106 10
6 / 24V DC Red PRCM41R 222110 10
Green PRCM41G 222107 10
24 / 60V DC Red PRCM42R 222111 10
Green PRCM42G 222124 10
110 / 230V DC Red PRCM43R 222112 10
Green PRCM43G 222125 10

A RC group Arc suppression circuit


For use with sockets: 6 / 24V AC PRCM51 222113 10
PRCG-ES15/2N 24 / 60V AC PRCM52 222114 10
B PRCG-ES15/3N
PRCG-ES15/4N
110 / 240V AC PRCM53 222115 10

C Led No protection against polarity inversion


and varistor Coil energizing indication
AC/DC voltage allowed
For use with sockets: 6 / 24V AC Red PRCM91R 222116 10
D PRCG-ES15/2N Green PRCM91G 222126 10
PRCG-ES15/3N 110 / 230V AC Green PRCM93G 222120 10
PRCG-ES15/4N
PRCGZT80
E
Varistor group No indication
F Protection against overvoltage
24V AC PRCM71 222121 10
For use with sockets:
PRCG-ES15/2N 230V AC PRCM73 222122 10
PRCG-ES15/3N
PRCG-ES15/4N
G

A.6
Series PRC
Technical data
Sockets for miniature plug-in relays
PRCG-ES15/2N PRCG-ES15/3N PRCG-ES15/4N
Screw terminals Screw terminals Screw terminals
Two levels Two levels Two levels
Specifications
Nominal load (A) 12 (300V) 10 (300V) 10 (300V)
Dielectric strength
Adjacent screws (kV) 3 3 3
Screws - rail (kV) 3 3 3
Terminals Type Screw Screw Screw
M4, Pozidriv M4, Pozidriv M3, Pozidriv
Max. torque (Nm) 0,7 0,7 0,7

Technical data
Protection category IP20 IP20 IP20
Capacity Solid wire (mm2) 2x2.5 2x2.5 2x2.5
Flexible wire 22-14 AWG 22-14 AWG 22-14 AWG
Ambient temperature (ºC) -40 ... +70 -40 ... +70 -40 ... +70

Sockets for 8-11 pin standard plug-in relays


PRCZ8 PRCG08 PRCZ11 PRCG11
Screw terminals 8 pin Screw terminals 11 pin
One level Solder terminal socket One level Solder terminal socket
Specifications
Nominal load (A) 10 (250V) 10 (250V) 10 (250V) 10 (250V)
Dielectric strength (kV) 2.5 2.5 A
Adjacent screws (kV) 2.5 2.5
Screws - rail (kV) 3 3
Terminals Type Screw Hard brass Screw Hard brass
M3, Pozidriv tin-plated terminals M3, Pozidriv tin-plated terminals B
Max. torque (Nm) 0,7 0.7
Protection category IP20 IP20
Capacity Solid wire (mm2) 2x2.5 2x2.5
Flexible wire 22-14 AWG 22-14 AWG C
Ambient temperature (ºC) -40 ... +70 -40 ... +70

Sockets for miniature P.C.B. relays D


PRCGZ80
Screw terminals
Two levels
Specifications
E
Nominal load (A) 12 (300V)
Dielectric strength
Adjacent screws
Screws - rail
(kV)
(kV)
3
3
F
Terminals Type Screw
M4, Pozidriv
Max. torque (Nm)
Protection category
0,7
IP20
G
2
Capacity Solid wire (mm ) 2x2.5
Flexible wire 22-14 AWG
Ambient temperature (ºC) -40 ... +70
H

A.7
Series PRC
Miniature plug-in relays
PRC4M20... PRC4M30... PRC4M40...
2 pole 3 pole 4 pole
Contacts
Number of contacts 2 changeover 3 changeover 4 changeover
Standard material AgNi AgNi AgNi
Optional material AgNi/Au 5µ AgNi/Au 5µ AgNi/Au 5µ
Voltage
Max switching AC/DC (poll. 3) 250V 250V 250V
voltage AC (poll. 2) 400V 400V 400V
Min switching voltage AC/DC 5V 5V 5V
Current
Rated load AC1 (A) 12 (250V AC) 10 (250V AC) 6 (250V AC)
AC15 (A) 4 (250V AC) 4 (250V AC) 2,5 (250V AC)
DC1 (A) 12 (24V DC) 10 (24V DC) 6 (24V DC)
Plug-in relays

Min. switching current (mA) 5 5 5


Max. inrush current (A) 24 20 12
Rated current (A) 12 10 6
Max. breaking capacity (VA) 3000 2500 1500
Resistance (mΩ) H100 H100 ≤100
(100mA, 24V) (100mA, 24V) (100mA, 24V)
Max. operating frequency
At rated load cycles/hour 1200 1200 1200
No load cycles/hour 18000 18000 18000
Coil
Rated voltage AC 50/60Hz (V) 6 ... 240 6 ... 240 6 ... 240
DC (V) 5 ... 220 5 ... 220 5 ... 220
A Must release AC
time voltage DC
G0.2 Un
G0.1 Un
G0.2 Un
G0.1 Un
G0.2 Un
G0.1 Un
Operating range of supply voltage Table 1, 2 Table 1, 2 Table 1, 2
Rated power AC 50Hz (VA) 1.5 1.6 1.6
B consumption
DC
60Hz (VA)
(W)
1.3
0.9
1.3
0.9
1.3
0.9
AC/DC (W) - - -
Insulation
Insulation category C250 C250 B250
C Insulation rated voltage (VAC) 250 250 250
Dielectric Coil-Contact (VAC) 2500 2500 2500
strength Contact-Contact (VAC) 1500 1500 1500
Table 1. Coil data DC version
Pole-Pole (VAC) 2500 2500 2000 Rated Coil Coil operating range V DC
D Contact coil Clearance mm G 2.5 G 2.5 G 1.6 voltage resistance Min. Max.
distance Creepage mm G4 G4 G 3.2 V DC Ω (at 20ºC) (at 55ºC)
General data 12 160 9.6 13.2
Operating time AC (ms) 10 10 10 24 640 19.2 26.4
E (typical value)
Release time
DC
AC
(ms)
(ms)
13
8
13
8
13
8
48 2600 38.4 52.8
110 13600 88 121
(typical value) DC (ms) 3 3 3 220 54000 176 242
Electrical life Resistive G 105 G 105 G 105

F Cos ϕ
(12A, 250V AC)
See curves
(10A, 250V AC)
See curves
(6A, 250V AC)
See curves
Table 2. Coil data AC 50/60Hz version
Mechanical life (cycles) G 107 G 107 G x107 Rated Coil Coil operating range V AC
Ambient Storage (ºC) -40 ... +85 -40 ... +85 -40 ... +85 voltage resistance Min. Max.
temperature Operating AC (ºC) -40 ... +55 -40 ... +55 -40 ... +55 V AC Ω (at 20ºC) (at 55ºC)
G DC (ºC) -40 ... +70 -40 ... +70 -40 ... +70 12 39 9.6 13.2
Cover protection category IP40 IP40 IP40 24 158 19.2 26.4
Shock resistance (g) 10 10 10 48 640 38.4 52.8
Vibration resistance (g) 5 5 5 120 3770 88 121
H (for 10..150Hz) (for 10..150Hz) (for 10..150Hz) 230 16100 184 253

A.8
Series PRC
Miniature 2 pole plug-in relays
Electrical life at AC resistive load Electrical life reduction factor at AC Max. DC resistive load breaking
inductive load capacity

Current (A)
Number of cycles (N)

Reduction factor (F)


.
.

.
cosϕ
. . . .

Technical data
Power factor .
Breaking capacity (kVA) Voltage (V)
N cosϕ = N x F

Miniature 3 pole plug-in relays


Electrical life at AC resistive load Electrical life reduction factor at AC Max. DC load breaking capacity
inductive load
A
Current (A)
Number of cycles (N)

resistive load T = 0ms


Reduction factor (F)

.
. inductive load T = 40ms
B
. .
. C
cosϕ .
. . . .
. . . . . . Power factor .
Breaking capacity (kVA) Voltage (V) D
N cosϕ = N x F

E
Miniature 4 pole plug-in relays
Electrical life at AC resistive load Electrical life reduction factor at AC Max. DC resistive load breaking F
inductive load capacity
Number of cycles (N)

Current (A)

G
Reduction factor (F)

.
.

. .
H
.
.
. . . .
cosϕ
.
I
Power factor
Voltage (V)
. .
Breaking capacity (kVA) N cosϕ = N x F
X

A.9
Series PRC
Standard 8-11 pin plug-in relays
PRC2P20... PRC3P30...
Standard 8-pin
Contacts
Number of contacts 2 changeover 3 changeover
Standard material AgNi AgNi
Optional material AgNi/Au 5µ AgNi/Au 5µ
Voltage
Max switching AC/DC (poll. 3) 250V 250V
voltage AC (poll. 2) 400V 400V
Min switching voltage AC/DC 10V (AgNi) 10V (AgNi)
5V (AgNi/Au 5µ) 5V (AgNi/Au 5µ)
Current
Rated load AC1 (A) 10 (250V AC) 10 (250V AC)
AC15 (A) 4 (250V AC) 4 (250V AC)
Plug-in relays

DC1 (A) 10 (24V DC) 10 (24V DC)


Min. switching current (mA) 5 5
Max. inrush current (A) 30 30
Rated current (A) 10 10
Max. breaking capacity (VA) 2500 2500
Resistance (mΩ) H100 (100mA, 24V) H100 (100mA, 24V)
Max. operating frequency
At rated load cycles/hour 1200 1200
No load cycles/hour 12000 12000
Coil
Rated voltage AC 50/60Hz (V) 6 ... 240 6 ... 240
DC (V) 6 ... 220 6 ... 220
A Must release time AC
voltage DC
G0.15 Un
G0.1 Un
G0.15 Un
G0.1 Un
Operating range of supply voltage Table 1, 2 Table 1, 2
Rated power AC 50Hz (VA) 2,7 2,7
consumption 60Hz (VA)
B DC (W)
2,5
1,5
2,5
1,5
AC/DC (W) - -
Insulation
Insulation category C250 C250
Table 1. Coil data DC version
C Insulation rated voltage (VAC) 250 250
Dielectric strength Coil-Contact (VAC) 2500 2500 Rated Coil Coil operating range V DC
Contact-Contact (VAC) 1500 1500 voltage resistance Min. Max.
Pole-Pole (VAC) 2000 2000 V DC Ω (at 20ºC) (at 55ºC)
D Contact coil
distance
Clearance
Creepage
mm
mm
G3
G 4.2
G3
G 4.2
12
24
110
430
9.6
19.2
13.2
26.4
General 48 1750 38.4 52.8
Operating time AC (ms) 12 12 110 9200 88 121
(typical value) DC (ms) 12 12
E Release time AC (ms) 10 10
220 37000 176 242

(typical value) DC (ms) 7 7 Table 2. Coil data AC 50/60Hz version


Electrical life Resistive G 2x105 (10A, 250V AC) G 2x105 (10A, 250V AC)
Cos ϕ See curves See curves Rated Coil Coil operating range V AC
F Mechanical life (cycles) G 2x107 G 2x107 voltage resistance Min. Max.
Ambient Storage (ºC) -40 ... +85 -40 ... +85 V AC Ω (at 20ºC) (at 55ºC)
temperature Operating AC (ºC) -40 ... +55 -40 ... +55 12 18.5 9.6 13.2
DC (ºC) -40 ... +70 -40 ... +70 24 75 19.2 26.4
G Cover protection category IP40 IP40 48 305 38.4 52.8
Shock resistance (g) 10 10 120 1910 96 132
Vibration resistance (g) 5 5 230 7080 184 253

H Electrical life at AC resistive load Electrical life reduction factor at AC


inductive load
Max. DC load breaking capacity
Number of cycles (N)

Current (A)

I .
Reduction factor

resistive load T = 0ms


.
. inductive load T = 40ms
.
X .
. .
. .
. .
. . . . . . . . .
. . . . . . Power factor .
Breaking capacity (kVA) Voltage (V)
N cosϕ = N x F N cosϕ = N x F

A.10
Series PRC
Interface plug-in relays
PRC1S13...

Contacts
Number of contacts 1 changeover
Standard material AgSnO2
Optional material
Voltage
Max switching AC/DC (poll. 3) AC 250V / DC 150V
voltage AC (poll. 2) AC 400V / DC 300V
Min switching voltage AC/DC 12V
Current
Rated load AC1 (A) 6 (250V AC)
AC15 (A)
DC1 (A) 6 (24V DC)

Technical data
Min. switching current (mA) 10
Max. inrush current (A) 15
Rated current (A) 6
Max. breaking capacity (VA) 1500V
Resistance (mΩ) H100
(100mA, 24V)
Max. operating frequency
At rated load 360 cycles/hour
No load 72000 cycles/hour
Coil
Rated voltage AC/DC (V) 24, 230
AC 50/60Hz (V) 230
DC (V) 12, 24
Must release time AC G0,2 Un A
voltage DC G0,1 Un
Operating range of supply voltage See Table 1
Rated power AC 50Hz (VA) 0.6...1.9
consumption 60Hz (VA) - B
DC (W) 0.33
AC/DC (W) 0.48 (at 24V), 1.8 (at 230V)
Insulation
Insulation category C250 C
Insulation rated voltage (VAC) 400
Dielectric strength Coil-Contact (VAC) 4000
Contact-Contact (VAC) 1000
Pole-Pole (VAC) - D
Contact coil Clearance mm G8
distance Creepage mm G8
General
Operating time
(typical value)
AC
DC
(ms)
(ms)
8
6
E
Release time AC (ms) 15
(typical value) DC (ms) 8
Electrical life Resistive
Cos ϕ
Table 1. Interface relay
F
Mechanical life (cycles)
Ambient Storage (ºC) 20x106 Rated Coil operating range V DC
temperature Operating AC (ºC) -40 ... +70 voltage Min. Max.
DC (ºC) -20 ... +55 V G
Cover protection category -20 ... +55 12 DC 9 17
Shock resistance (g) IP20 24 DC 17 30
Vibration resistance (g) 10 24 AC/DC 18 30
0.062’’ DA 230 AC 80 250 H
(10 ... 55Hz) 230 AC/DC 185 250

A.11
Series PRC
Interface relay for PLC systems
PRC1T10...

Contacts
Number of contacts 1 changeover
Standard material AgNi
Optional material
Voltage
Max. switching voltage AC/DC AC 400V / DC 300V
Min. switching voltage AC/DC 5V
Current
Rated load AC1 (A) 16 (250V AC)
DC1 (A) 16 (24V DC)
Min. switching current (mA) 5
Max. inrush current (A) 30
Rated current (A) 16
Plug-in relays

Max. breaking capacity (VA) 4000


Min. breaking capacity (W) 0,3
Resistance (mΩ) H100 (at 1A, 24V)
Max. operating frequency
At rated load 600 cycles/hour
No load 72000 cycles/hour
Coil
Rated voltage AC 50/60Hz (V) 24,120, 230
DC (V) 12, 24, 110
Must release time AC G0.15 Un
voltage DC G0.1 Un
Operating range of supply voltage See Table 1, 2
A Rated power AC (VA) 0.75
consumption DC (W) 0.4
Insulation
Insulation category C250
B Insulation rated voltage
Dielectric strength Coil-Contact
(VAC)
(VAC)
400
5000 Table 1. Coil data DC version
Contact-Contact (VAC) 1000
Pole-Pole (VAC) - Rated Coil resistance Coil operating range V DC
Contact coil Clearance mm G 10
C distance Creepage mm G 10
voltage
V DC
(±10%) at20ºC

U Min. U Max.

General 12 360 8.4 30.6


Operating time AC (ms) 7
24 1440 16.8 61.2
(typical value) DC (ms) 7
110 25200 77 280
D Release time AC (ms) 5
(typical value) DC (ms) 3
Electrical life Resistive (s) G 0.7 x 105 (at 16A, 250VAC)
Cos ϕ See curves Table 2. Coil data AC 50/60Hz version
E L/R = 40ms
Mechanical life (cycles)
G 105 (at 0.12A, 220VDC)
3x107 Rated Coil resistance Coil operating range V AC
Ambient Storage (ºC) -40 ... +70 voltage (±10%) at20ºC U Min. U Max.
temperature Operating (ºC) -40 ... +70 V AC Ω
F Cover protection category
Shock resistance (g)
IP40
30
24
120
400
10200
19.2
96
28.8
144
Vibration resistance (g) 10 (for 10 ... 150Hz) 230 38500 184 276

H Electrical life at AC resistive load Electrical life reduction factor at AC


inductive load
Max. DC load breaking capacity
Number of cycles (N)

Current (A)

I
Reduction factor

.
.

X .

.
. . .
Power factor .
. . . . .
Breaking capacity (kVA) Voltage (V)
N cosϕ = N x F

A.12
Series PRC
Interface relay for PLC systems
PRC1T20...

Contacts
Number of contacts 2 changeover
Standard material AgNi
Optional material
Voltage
Max. switching voltage AC/DC AC 400V / DC 300V
Min. switching voltage AC/DC 5V
Current
Rated load AC1 (A) 8 (250V AC)
DC1 (A) 8 (24V DC)
Min. switching current (mA) 5
Max. inrush current (A) 15

Technical data
Rated current (A) 8
Max. breaking capacity (VA) 2000
Min. breaking capacity (W) 0,3
Resistance (mΩ) H100 (at 1A, 24V)
Max. operating frequency
At rated load 600 cycles/hour
No load 72000 cycles/hour
Coil
Rated voltage AC 50/60Hz (V) 24, 230
DC (V) 12, 24
Must release time AC G0.15 Un
voltage DC G0.1 Un
Operating range of supply voltage See Table 1, 2
Rated power AC (VA) 0.75 A
consumption DC (W) 0.4
Insulation
Insulation category C250
Insulation rated voltage
Dielectric strength Coil-Contact
(VAC)
(VAC)
400
5000
B
Contact-Contact (VAC) 1000 Table 1. Coil data DC version
Pole-Pole (VAC) - Rated Coil resistance Coil operating range V DC
Contact coil
distance
Clearance
Creepage
mm
mm
G 10
G 10
voltage (±10%) at20ºC U Min. U Max. C
V DC Ω
General 12 360 8.4 30.6
Operating time AC (ms) 7
24 1440 16.8 61.2
(typical value) DC (ms) 7
Release time AC (ms) 5
110 25200 77 280 D
(typical value) DC (ms) 3
Electrical life Resistive (s) G 0.7 x 105 (at 8A, 250VAC)
Cos ϕ See curves Table 2. Coil data AC 50/60Hz version
L/R = 40ms G 105 (at 0,12A, 220VDC) E
Mechanical life (cycles) 3x107 Rated Coil resistance Coil operating range V AC
Ambient Storage (ºC) -40 ... +70 voltage (±10%) at20ºC U Min. U Max.
temperature Operating (ºC) -40 ... +70 V AC Ω
Cover protection category IP40 24 400 19.2 28.8 F
Shock resistance (g) 20 120 10200 96 144
Vibration resistance (g) 10 (for 10 ... 150Hz) 230 38500 184 276

Electrical life at AC resistive load Electrical life reduction factor at AC Max. DC load breaking capacity H
inductive load
Number of cycles (N)

Current (A)

I
Reduction factor

.
.

. X
.
. . .
. . . . Power factor .
Breaking capacity (kVA) Voltage (V)
N cosϕ = N x F

A.13
Series PRC
Dimensional drawings
Miniature Standard 8-11 pin
2 poles

.
.

.
.
.
. . .
.

.
Plug-in relays

3 poles

.
.

. Socket. Screw terminals. One level


.

.
.
A . .
.

. .

.
B
4 poles
.
.

C
.

.
.

D
.

.
E
Socket. Solder terminals

F Socket. Screw terminals. Two levels

G
.

H
.

.
.

A.14
Series PRC

Interface relay Socket for miniature P.C.B. relays

.
.

Dimensions
A

A.15
Series M
Auxiliary minicontactors
Ith = 16A
• Control circuit: Alternating current up to 600V
Direct current up to 250V
• Terminal numbering in accordance with EN 50011
• Fixing system for rapid and simple mounting by clamping onto standard
Auxiliary minicontactors

35 mm DIN rail (EN 50022).


• Screw and push-on terminals protected against accidental contacts in
accordance with VDE 0106 T.100 and VBG4.
• Printed circuit version.
• Ring terminal version.
• Facility to mount instant or timed auxiliary contact blocks and voltage
supressor blocks.
• Maximum number of auxiliary contacts to add: 6
• Degree of protection IP20 (EN 60529).
• According to IEC/EN 60947-1.

Standards General data


A IEC/EN 60947-5-1 BS 4794 Maximum number of contacts (MCR...) 4
IEC/EN 60947-1 CENELEC HD 420 Rated thermal current (Ith) θ H 60º (A) 16
EN 50002 NFC 63-110 Rated operational voltage (Ue) acc. IEC 60947-1 (V) 690
NFC 63-140
B EN 50005
EN 50011 CSA C22.2/14
Insulation voltage (Ui) acc. IEC 60947-1
Utilisation category:
(V) 750

UL 508 VDE 0660 AC-15 V 110 220/240 380/400 415 440 500 660/690
A 6 6 4 4 3 2.5 1.5
C
DC-13 V 24 48 110 220
Approvals A 5 3.5 1.2 0.6
D
Standard voltages
E cULus DEMKO NEMKO
To complete the catalogue number, replace the symbol © by the code
corresponding to the voltage and frequency of the control circuit.
Alternating current (V). Bifrequency coil
F © 10 1 2 9 3 4 5 6 7 8 12 13
SEMKO SETI AC 12 24 42 48 110 120 220 230 240 440 380 400
50/60Hz 115
G Voltage operating limits of dual-frequency coil:
at 60Hz = 0.85 a 1.1 x Us
at 50Hz = 0.8 a 1.1 x Us for uninterrupted duty (ED=100%), temperature = 40ºC

Alternating current (V)


H Lloyd’s Bureau RINA
© A E G K M N S U W Y
Register Veritas
AC 48 115 220 260 380 415 500
50Hz 127 240 400 440
I AC 6 32 60 208 240 440 480 600
60Hz 220 277

Direct current (V)


X
© A B C D E F G H I J K L N 17 R S 16

Order codes pg. A.17 DC 6 12 32 24 36 42 48 60 72 110 120 125 220 230 240 250 440
!
Auxiliary contacts blocks ! pg. A.18
Accessories ! pg. A.20 Direct current (V) - Wide voltage range
Technical data ! pg. A.26 © WD WE WG WI WJ WN
Combinations of contacts ! pg. A.32
DC 24 33 48 72 110 220
Dimensions ! pg. A.40

A.16
Series M
Auxiliary minicontactors
Contacts acc. Control circuit: alternating current Control circuit: direct current
EN 50011
Cat. no. (1) Pack Cat. no. (1) Pack
•3 •1
Ref. no. see Ref. no.
•4 •2 bottom see bottom

Screw terminal
40E 4 0 MCRA040AT © 20 MCRC040AT © 10
31E 3 1 MCRA031AT © 20 MCRC031AT © 10
22E 2 2 MCRA022AT © 20 MCRC022AT © 10
13E 1 3 MCRA013AT © 20
04E 0 4 MCRA004AT © 20

Ring terminal
40E 4 0 MCRA040AR © 20 MCRC040AR © 10
31E 3 1 MCRA031AR © 20 MCRC031AR © 10

Order codes
22E 2 2 MCRA022AR © 20 MCRC022AR © 10
13E 1 3 MCRA013AR © 20
04E 0 4 MCRA004AR © 20

Terminal: faston 2x2,8 insulated (2)


40E 4 0 MCRA040AF © 20 MCRC040AF © 10
31E 3 1 MCRA031AF © 20 MCRC031AF © 10
22E 2 2 MCRA022AF © 20 MCRC022AF © 10
13E 1 3 MCRA013AF © 20
04E 0 4 MCRA004AF © 20
A

Terminal: printed circuit


40E 4 0 MCRA040AI © 20 MCRC040AI © 10 B
31E 3 1 MCRA031AI © 20 MCRC031AI © 10
22E 2 2 MCRA022AI © 20 MCRC022AI © 10
13E 1 3 MCRA013AI © 20
04E 0 4 MCRA004AI © 20
C

Spare coil MB0A © 10 MB0C © 10 D

E
(1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and fre-
quency of the control circuit. (see pg.A.16).
(2) Terminal: - with wire 1.5 mm2: Ie = 16A - with wire 1 mm2: Ie = 10A
Insulated terminal type B2.8x0.8 with wire 1 mm2: Ie = 8A to DIN 46247 F
Faston terminal 1 x 6.3 on request, replace the letter F by H in the catalogue number

Auxiliary minicontactors interface G


Contacts acc. to Control circuit: direct current 24V / 1.2W (3) Control circuit: direct current 24V / 2W (4)
EN 50011
Operating limits Operating limits
•3 •1 from 19 to 30V (0.8-1.25xUs) from 17 to 30V (0.7-1.25xUs)
Cat. no. Ref. no. Pack Cat. no. Ref. no. Pack H
•4 •2

Screw
terminal
40E
31E
4
3
0
1
MCRI040ATD
MCRI031ATD
100530
100531
10
10
MCRK040ATD
MCRK031ATD
100533
100534
10
10
I
22E 2 2 MCRI022ATD 100532 10 MCRK022ATD 100535 10

Spare coil MB0ID 100470 10 MB0KD 100471 10


X

(3) No possibility of adding instantaneous auxiliary blocks.


(4) Facility to mount instantaneous auxiliary contact block of two contacts (MARN2...) For reference numbers,
or two instantaneous auxiliary contact blocks of one contact (MARL1...). see chapter X, pg. X.2

A.17
Series M
Instantaneous auxiliary contacts blocks
Number of Combination with Contacts acc. to EN 50005 Cat. no. Ref. no. Pack
contacts MCRA040AT© (40E) Designation
according to EN 50011 (block marking) •3 •1

Front mounting •4 •2
Screw terminal
2 60E 20 2 0 MARN220AT 100994 10
2 51E 11 1 1 MARN211AT 100993 10
Auxiliary minicontactors

2 42E 02 0 2 MARN202AT 100992 10

Ring terminal
2 60E 20 2 0 MARN220AR 103349 10
2 51E 11 1 1 MARN211AR 103350 10
2 42E 02 0 2 MARN202AR 103351 10

Screw terminal
4 80E 40 4 0 MARN440AT 100991 10
4 71E 31 3 1 MARN431AT 100990 10
4 62E 22 2 2 MARN422AT 100989 10
4 53E 13 1 3 MARN413AT 100988 10
4 44E 04 0 4 MARN404AT 100987 10

Terminal : Ring terminal


4 80E 40 4 0 MARN440AR 103352 10
A 4
4
71E
62E
31
22
3
2
1
2
MARN431AR
MARN422AR
103353
103354
10
10
4 53E 13 1 3 MARN413AR 103355 10
4 44E 04 0 4 MARN404AR 103300 10

B
Terminal: faston 2x2.8 insulated (1)
4 80E 40 4 0 MARF440AF 100503 10
4 71E 31 3 1 MARF431AF 100504 10
C 4 62E 22 2 2 MARF422AF 100505 10
4 53E 13 1 3 MARF413AF 100506 10
4 44E 04 0 4 MARF404AF 100507 10

D
(1) Terminal with wire 1 mm2: Ie = 10A
Insulated terminal type B 2.8x0.8 with wire 1 mm2: Ie = 8A
E

A.18
Series M
Instantaneous auxiliary contacts blocks
Contacts acc. to EN 50005 Cat. no. Ref. no. Pack
Number of Combination with
contacts MCRA040AT© (40E) Designation •3 •1
according to EN 50011 (Block marking)

Lateral mounting •4 •2
• One or two blocks to cover combinations of 5 or 6 contacts without increasing the height of the basic unit.
Screw terminal
1 50E 10 1 0 MARL110AT 100513 10
1 – 01 0 1 MARL101AT 100514 10

Ring terminal
1 50E 10 1 0 MARL110AR 103556 10
1 – 01 0 1 MARL101AR 103557 10

Order codes
Terminal : Faston 2x2,8 insulated (1)
1 50E 10 1 0 MARL110AF 100515 10
1 – 01 0 1 MARL101AF 100516 10

Terminal : Printed circuit


1 50E 10 1 0 MARL110AI 100517 10
1 – 01 0 1 MARL101AI 100518 10
A

• One or two additional blocks, when 9 or 10 contacts are required (combination possible with the front mounting block)
• One or two additional blocks on both sides, to cover up to 8 contacts (combination only possible with lateral blocks) B
Screw terminal
1 50E 10 1 0 MARL110ATS 100519 10
1 – 01 0 1 MARL101ATS 100520 10
C
Ring terminal
1 50E 10 1 0 MARL110ARS 103299 10
1 – 01 0 1 MARL101ARS 103298 10 D

Terminal : Faston 2x2,8 insulated (1) E


1 50E 10 1 0 MARL110AFS 100521 10
1 – 01 0 1 MARL101AFS 100522 10

F
Terminal : Printed circuit
1 50E 10 1 0 MARL110AIS 100523 10
1 – 01 0 1 MARL101AIS 100524 10
G

H
(1) Terminal with wire 1 mm2: Ie = 10A
Insulated terminal type B2.8x0.8 with wire 1 mm2: Ie = 8A
I

A.19
Series M
Accessories
For use Time Function Ue Cat. no. Ref. no. Pack
with:

Electronic timer block Lateral or front fixing on the contactor


MCR..MC_ ... 0.5 - 60 sec. Delay ON 24 to 250V AC/DC MREBC10AC2 100541 10
MCR..MC_ ... 0.2 - 24 sec. Delay ON 24 to 250V AC/DC MREBC20AC2 100542 10
Auxiliary minicontactors

Timer fitment For fixing onto 35mm DIN-rail (EN 5022)


MREBC... MVB0R 100543 10

For use Type Control Ue Cat. no. Ref. no. Pack


with:

Voltage suppresor Connection and (plug-in) fixing onto front of the contactor
block
MCRA,MC_ ... RC AC 12 to 60V 50/60Hz MP0AAE1 100544 10
MCRA,MC_ ... RC AC 72 to 250V 50/60Hz MP0AAE2 100545 10
MCRC,MC_ ... Diode DC 6 to 250V DC MP0CAE3 100546 10
MCRC, MC_... Varistor AC/DC 24-48V MP0DAE4 100536 10

A
For use Cat. no. Ref. no. Pack
with:
B Mechanical Kit comprising mechanical interlock and contactor jointing parts
interlock
MCR, MC_ ... MMH0 100547 10
C

D
For use Cat. no. Ref. no. Pack
with:

Identification MCR, MC_ ... Sheets of labels (10 sheets of 260 labels each) EAT 260 100548 1
E MCR, MC_ ... Labelling plate base. Plug-in labelling plate bases SPR 100549 1
(50 pieces in one pack)

A.20
Series M
Notes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Order codes
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

A.21
Series RL
Auxiliary contactors
Ith = 20A
• Control circuit: Alternating current up to 690V
Direct current up to 440V
• Terminal numbering in accordance with EN 50005 and EN 50011
• Fixing system for rapid and simple mounting onto standard 35mm
DIN-rail (EN 50022-35)
• Terminals protected against accidental contact in accordance with
VDE 0106 T.100, VBG4
Auxiliary contactors

• Ring terminal versions


• Three coil terminals
• Facility to mount side and/or front instantaneous contact blocks, timed
auxilary contacts, mechanical latch, voltage supressor blocks and interface
modules.
• Degree of protection IP20 (EN 60529)

Standards General data


A IEC/EN 60947-5-1 BS 4794 Maximum number of contacts (RL...) 4
IEC/EN 60947-1 CENELEC HD410 Rated thermal current (Ith) θ ≤ 55º (A) 20
EN 90947 CENELEC HD420 Rated operational voltage (Ue) (V) 690
B EN 60947 NFC 63-110 Insulation voltage (Ui) (V) 1000
EN 50005 NFC 63-140 Utilisation category:
EN 50011 CSA C22.2/14 AC-15 V 120 230/220 400/380 440/415 500 690/660
UL 508 VDE 0660/102 A 10 10 6 5 4 2
C NEMA ICS 1
DC-13 V 24 48 110 220 440
A 6 4 2 0.7 0.35
D Approvals

E Standard voltages
cULus DEMKO NEMKO
To complete the catalogue number, replace the symbol © by the code corres-
F ponding to the voltage and frequency of the control circuit.

Alternating current (V). Dual-frequency coil


SEMKO SETI © 1 2 9 3 4 5 6 7 13 8 15
G AC 24 42 48 110 120 220 230 240 400 440 480
50/60Hz 115

Alternating current (V)


H © A B E K L N T U W Y Z
Lloyd’s Bureau AC 32 127 220 380 415 500 660
Register Veritas 50Hz 230 400 690
I AC 6 12 208 277 380 480 460 600
60Hz

Direct current (V)


X © B D E F G H I J K N P R T X
Order codes ! pg. A.23 DC 12 24 36 42 48 60 72 110 120 220 230 240 250
Auxiliary contacts blocks ! pg. A.23 440
Accessories ! pg. A.24
Technical data ! pg. A.34 Direct current (V) - Wide voltage range
Diagrams ! pg. A.36
Combinations of contacts pg. A.38 © WB WD WE WF WG WH WI WJ WK WN WP WR WT WX
!
Dimensions ! pg. A.42 DC 12 24 33 42 48 60 72 110 125 220 230 240 250

A.22
Series RL
Auxiliary contactors
Contacts Control circuit: Alternating current up to 690V Control circuit: Direct current up to 440V
Cat. no. (1) Pack Cat. no. (1) Pack
•3 •1 •7 •5
Ref. no. Ref. no.
•4 •2 •8 •6 see bottom see bottom
Screw terminal
4 0 0 0 RL4RA040T © 5 RL4RD040T © 10
3 1 0 0 RL4RA031T © 5 RL4RD031T © 10
2 2 0 0 RL4RA022T © 5 RL4RD022T © 10
0 4 0 0 RL4RA004T © 5 RL4RD004T © 10
1 1 1 1 RL4RA022G © 5 RL4RD022G © 10

Ring terminal
4 0 0 0 RL4RA040R © 5 RL4RD040R © 10
3 1 0 0 RL4RA031R © 5 RL4RD031R © 10
2 2 0 0 RL4RA022R © 5 RL4RD022R © 10

Order codes
0 4 0 0 RL4RA004R © 5 RL4RD004R © 10

Spare coil Screw terminal


LB1A © 5 LB1D © 5

Ring terminal
LR1A © 5 LR1D © 5

A
(1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and fre-
quency of the control circuit. (see pg. A.22).
B
Auxiliary contacts
Instantaneous Number of Contacts Function Time Cat. no. Ref. no. Pack
contacts
•3
C
•1 •7 •5

•4 •2 •8 •6
Frontal
mounting
Screw terminal
1 1 0 0 0 BCLF10 104700 10
D
1 0 1 0 0 BCLF01 104701 10
1 0 0 1 0 BCLF10G 104702 10
1 0 0 0 1 BCLF01G 104703 10

Ring terminal
E
1 1 0 0 0 BCRF10 108901 10
1 0 1 0 0 BCRF01 108902 10

F
Side Screw terminal
mounting 2 2 0 0 0 BRLL20 104704 10
2 1 1 0 0 BRLL11 104705 10 G

Pneumatic timer blocks


H
Frontal Screw terminal
mounting 2 0 0 1 1 Delayed ON 0.1 - 30 sec. BTLF30C 104709 10
2 0 0 1 1 Delayed ON 1 - 60 sec. BTLF60C 104710 10 I
2 0 0 1 1 Delayed OFF 0.1 - 30 sec. BTLF30D 104711 10
2 0 0 1 1 Delayed OFF 1 - 60 sec. BTLF60D 104712 10

Ring terminal
2 0 0 1 1 Delayed ON 0.1 - 30 sec. BTRF30C 108903 10 X
2 0 0 1 1 Delayed ON 1 - 60 sec. BTRF60C 108904 10
2 0 0 1 1 Delayed OFF 0.1 - 30 sec. BTRF30D 108905 10
2 0 0 1 1 Delayed OFF 1 - 60 sec. BTRF60D 108906 10

Sealing cover protection for pneumatic timer BTLFX 113001 5

For reference numbers,


see chapter X, pg. X.2 A.23
Series RL
Accessories
Number of Contacts Cat. no. Ref. no. Pack
contacts
•3 •1 •7 •5

•4 •2 •8 •6
Mechanical interlock Mechanical
- - - - - BELA 104723 5

Mechanical / electrical
2 0 2 - - BELA02 104724 5
Auxiliary contactors

Mechanical latch Frontal mounted to the contactor


blocks RL4RA..., RL4RD... RMLF © (1) see bottom 20

(1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and fre-
quency of the control circuit.

D G HC J N U Y
50Hz 24, 32 42, 48 110, 115, 120, 127 220, 230, 240 380, 400, 415, 440, 480 500, 660/690
60HZ 24, 32 48, 60 110, 115, 120, 127 208, 220, 240, 277 380, 400, 415, 440, 480 600
DC 24, 32, 36 42, 48 60, 72 110, 120, 125 220, 230, 240, 250 440

A For use Type Control circ. Ue Cat. no. Ref. no. Pack
with:

Transient voltage Directly connected parallel to the coil terminals, allows simultaneous use
B supressor block with auxiliary contact blocks.
RL4RA... R/C AC 12V ... 48V BSLR2G 104713 10
RL4RA... R/C AC 50V ... 127V BSLR2K 104714 10
RL4RA... R/C AC 130V ... 250V BSLR2R 104715 10
C RL4RD... Diode DC 12V ... 600V BSLDZ 104719 10

RL4RA..., RL4RD... Varistor AC / DC 24V ... 48V BSLV3G 104720 10


RL4RA..., RL4RD... Varistor AC / DC 50V ... 127V BSLV3K 104721 10
D RL4RA..., RL4RD...
RL4RA..., RL4RD...
Varistor
Varistor
AC / DC
AC / DC
130V ... 250V
277V ... 500V
BSLV3R
BSLV3U
104722
110836
10
10

E
For use Cat. no. Ref. no.
F with: Pack

Identification RL4RA..., RL4RD... Sheets of labels (10 sheets of 260 labels each) EAT 260 100548 1
RL4RA..., RL4RD... Labelling plate base. Plug-in labeling plate bases SPR 100549 1
(50 pieces in one pack)
G

For reference numbers,


see chapter X, pg. X.2

A.24
Series RL
Accessories (continued)
For use Control circuit Function Time Cat. no. Ref. no. Pack
with:

Electronic timer Directly connected parallel to the coil terminals, allows simultaneous use
module with auxiliary contact blocks.
RL4... 24-250V AC/DC Delayed ON 0,1 - 2 sec. BETL02C 113602 5
RL4... 24-250V AC/DC Delayed ON 1,5 - 45 sec. BETL45C 113603 5

RL4... 24-250V AC/DC Delayed OFF 0,1 - 2 sec. BETL02D 113604 5


RL4... 24-250V AC/DC Delayed OFF 1,5 - 45 sec. BETL45D 113605 5

For use Control circuit Type Ue Cat. no. Ref. no. Pack
with:

Interface module Directly connected parallel to the coil terminals, allows simultaneous use

Order codes
with auxiliary contact blocks.
RL4... 24-250V AC/DC Relay 24V IMRD 113606 5
RL4... 24-250V AC/DC Relay 48V IMRG 113607 5

RL4... 24-250V AC/DC Relay + forced 24V IMRFD 113608 5


operation
RL4... 24-250V AC/DC Relay + forced 48V IMRFG 113609 5
operation
RL4... 24-250V AC/DC Solid state 24V IMSSD 113610 5

RL4... 24-250V AC/DCAuto/Manual/Off Contr. 24-250V IMAMS 113611 5

B
Transient voltage RL4... 24-240V AC R/C 24-48V IMRC2G 113601 10
supressor block to RL4... 24-240V AC R/C 50-127V IMRC2K 113600 10
use with interface RL4... 24-240V AC R/C 130-240V IMRC2R 113599 10
modules
RL4... 24-240V AC Diode 12-600V IMD1Z 113595 10 C
RL4... 24-240V AC Varistor 24-48V IMV3G 113594 10
RL4... 24-240V AC Varistor 50-127V IMV3K 113593 10
RL4... 24-240V AC Varistor 130-240V IMV3R 113592 10
D

A.25
Series M
Technical data
General Mounting positions
Maximum number of contacts (MCR...) 4
Rated thermal current (Ith) θ ≤ 60º 16A
Rated operational voltage (Ue) acc. IEC 60947.1 690V
Insulation voltage (Ui) acc. IEC 60947.1 750V
Auxiliary minicontactors

Conformity to standards
IEC / EN 60947-5-1 IEC / EN 60947-1 BS 4794
With the same pick-up and drop-out voltage
EN 50002 EN 50005 EN 50011 With the same rated power
NFC 63-110 NFC 63-140 CENELEC HD 420
CSA C22.2/14 VDE 0660 UL 508
-7% of connection voltage
+4% of disconnection voltage
Approvals With the same rated power
cULus DEMKO NEMKO
SEMKO SETI RINA
-7% of connection voltage
Lloyd’s Register Bureau Veritas +4% of disconnection voltage
With the same rated power

Ambient conditions
Storage temperature -55ºC to +80ºC
Operation temperature -40ºC to +60ºC Terminal capacity
Altitude up to 3000m Nominal values
Terminal with screw M3.5 Tightening torque
A from 3000 to 4000m
from 4000 to 5000m
90%Ie 80%Ue
80%Ie 75%Ue
(with pozidrive head and safety flange)
Solid wire mm2
0.8 Nm - 7 Lb-in
0.75 to 2x2 w.
Flexible wire without terminal mm2 0.75 to 2.5x2 w.
Climatic resistance (IEC 68-2) Flexible wire with terminal with cap mm2 0.75 to 2.5x1 w
B Continuous tests 40 / 125 / 56 Ring terminal cap
mm2 0.75 to 1x2 w
0.8 Nm - 7 Lb/in
Cold (72h)
Temperature -40ºC
Dry heat (96h)
C Temperature +125ºC
Relative humidity < 50%
Humid heat (56 days)
Temperature +40ºC
D Relative humidity 95% Fast-on 2.8 - 2 insulated terminals mm2 1 x 2 w.
Cyclical tests (6 cycles) Terminal for printed circuit (Ø of PCB hole) 1.8mm
Humid heat Ring terminal cap 7.8mm
First half-cycle (12h) Fork terminal cap 6.5mm
E Low temperature
Relative humidity
+25ºC
93%
Second half-cycle (12h)
Low temperature +55ºC

F Relative humidity 95%

Shock resistance (IEC 68-2-27)


G Continously closed (at 0,8Us)
Admissible acceleration 25 g
Impulse duration 11 ms
Continously opened (no voltage)

H Admissible acceleration
Impulse duration
20 g
11 ms

Vibration resistance (IEC 68-2-6)


I Continously closed (at 0,8Us)
Admissible acceleration 15 g
Sweep between 10 - 200 Hz
Continously opened (no voltage)
X Admissible acceleration 5 g AC - 3.5 g DC
Sweep between 10 - 200 Hz

A.26

32764_A26_A44_E.indd 26 11-07-2005 15:34:41


Series M

Control circuit
MCRA... MCRC... MCRC.. MCRI... MCRK...

Rated insulation voltage (Ui) (V) 750 750 750 750 750
Standard voltages (Us)
50Hz (V) 24...690 – – – –
60Hz (V) 6...600 – – – –
DC (V) – 6...440 12...440 24 24
Voltage (1)
Operating limits xUs 0.8...1.1 0.8...1.1 0.7...1.3 0.8...1.25 0.7...1.25
Drop-out xUs 0.35...0.55 0.15...0.3 0.15...0.3 0.15...0.3 0.13...0.35
Consumption
Pick-up (VA) 26 – – – –

Technical data
Seal (VA) 4 – – – –
DC (W) – 3 4 1.2 2
Power factor
Pick-up (cos ϕ) 0.8 – – – –
Seal (cos ϕ) 0.35 – – – –
Power dissipation (W) 1.4 3 4 1.2 2
Opening and closing times
Values between ± %Us % +10...-20 +10...-20 +30...-30 +25...-20 +25...-20
Marking time at energisation NO (ms) 6...13 22...36 17...28 30...70 20...50
Marking time at de-energisation NC (ms) 8...16 9...12 9...12 9...16 9...16
Breaking time at energisation NC (ms) 5...11 18...27 12...25 20...45 18...35
Breaking time at de-energisation NO (ms) 6...13 5...7 5...7 5...9 5...9
Values at Us
Marking time at energisation NO (ms) 7...12 24...27 19...23 25...45 25...40
A
Marking time at de-energisation NC (ms) 8...16 9...11 9...11 9...16 9...16
Breaking time at energisation NC (ms) 6...10 20...26 15...21 25...35 20...30
Breaking time at de-energisation NO (ms) 6...13 5...8 5...8 5...9 5...9
Maximum time without voltage (ms) 3 3 3 3 3 B
(without effecting the closed magnetic circuit)
Mechanical endurance
Monofrequency x106 ops. 15 – – – –
Dual-frequency x106 ops. 10 – – – – C
DC x106 ops. – 10 10 10 10
Maximum rate (no load)
Monofrequency # ops./h 9000 – – – –
Dual-frequency # ops./h 3600 – – – – D
DC # ops./h – 9000 9000 9000 9000

E
Contact sequence (distance in mm)

Auxliary contact
F
Auxliary contact
NO NC

0 1.95 3.5 0 1.2 3.5 G


Auxliary contact MCR.....

H
0 2.1 3.5 0 0.7 3.5
Auxiliary MAR.....
contact
blocks I
Open Closed
X

A.27
Series M
Internal auxiliary contacts Tripping characteristics Ie/ue
MCR.....
Rated insulation voltage (Ui) acc. IEC 60947-1 750V DC Inductive circuit. DC-13 L/R ≤ 100 ms
Rated thermal current (Ith) θ ≤ 60ºC (1) 16A Electrical endurance 106 ops.
Making capacity (r.m.s.) acc. IEC 60947-5
AC-15 Ue ≤ 440V 50/60 Hz 160A
DC-13 Ue ≤ 220V DC 3A
Breaking capacity (r.m.s.) acc. IEC 60947-5
Auxiliary minicontactors

AC-15 Ue ≤ 440V 50/60 Hz 106A


DC-13 (L/R = 100 ms) Ue ≤ 220V DC 1.2A
Ue = 110V DC 3A
Ue = 48V DC 10A
Rated voltage and rated current Ue-Ie
.
AC-15 according to IEC 947 110/120V - 6A .
220/240V - 6A
.
380/400V - 4A
415/440V - 4A .
500V - 2.5A
.
660/690V - 1.5A
according to UL, CSA A600
DC-13 according to IEC 24V - 5A (1) 1 pole in series
(2) 2 poles in series
48V - 3.5 A
(3) 3 poles in series
110V - 1.2A
220V - 0.6A
440V - 0.25A
according to UL, CSA P600 Inductive circuit. DC-13 L/R ≤ 15 ms
DC
Minimum operational power (operational safety) 5 mA, 17V Electrical endurance 106 ops.
Short-circuit protection 10A
A (max.class gl fuse without welding)
Insulation resistance
between contacts > 10 mΩ
between contacts and earth > 10 mΩ
B between input and output > 10 mΩ
Guaranted no overlap of the contacts
Space 1,1 mm
minimum time > 2 ms
C Impedance 2.3 mΩ .
.
Terminal capacity Same as
.
main circuit
.
D .

(1) 1 pole in series


(2) 2 poles in series
E (3) 3 poles in series
Tripping characteristics (AC)
F AC AC-15 DC Inductive circuit DC-13 L/R ≤ 1 ms
Electrical endurance Electrical endurance 106 ops.

H .

. .
. .
I . .

. .

. .
X (1) 1 pole in series
(2) 2 poles in series
(3) 3 poles in series

A.28
Series M
External auxilary contact blocks Tripping characteristics Ie/ue
MARN..., MARL...

Rated insulation voltage (Ui) acc. IEC 60947-1 750V DC Inductive circuit. DC-13 L/R ≤ 100 ms
Rated thermal current (Ith) θ ≤ 60ºC (1) 10A Electrical endurance 106 ops.
Making capacity (r.m.s.) acc. IEC 60947-5
AC-15 Ue ≤ 220V 50/60 Hz 73A
Ue = 380V 50/60 Hz 38A
Ue = 690V 50/60 Hz 22A
DC-13 L/R = 100 ms Ue ≤ 100V DC 2.6A
Ue = 220V DC 1A
Ue = 440V DC 0.6A
Breaking capacity (r.m.s.) acc. IEC 60947-5
.
AC-15 Ue ≤ 220V 50/60 Hz 73A .
Ue = 380V 50/60 Hz 38A

Technical data
.
Ue = 690V 50/60 Hz 22A
.
DC-13 L/R = 100 ms Ue ≤ 100V DC 2A
Ue = 220V DC 0.8A .
Ue = 440V DC 0.4A
Rated voltage and rated currentl Ue-Ie (1) 1 pole in series
(2) 2 poles in series
AC-15 according to IEC 60947 110/120V - 6A
(3) 3 poles in series
220/240V - 6A
380/400V - 3A
415/440V - 3A
500V - 1A DC Inductive circuit. DC-13 L/R ≤ 15 ms
660/680V - 1A Electrical endurance 106 ops.
according to UL, CSA A600 A
DC-13 according to IEC 60947 24V - 4A
48V - 2A
110V - 0.7A
220V - 0.3A B
440V - 0.1A
according to UL, CSA Q600
Minimum operational power (operational safety) 5 mA, 17V
Short-circuit protection 10A
.
.
C
(max.class gl fuse without welding) .
Insulation resistance
between contacts > 10 mΩ .

between contacts and earth > 10 mΩ .


D
between input and output > 10 mΩ
Guaranteed no overlap of the contacts (1) 1 pole in series
(2) 2 poles in series
Space
minimum time
0.5 mm
> 2 ms
(3) 3 poles in series E
Impedance 2.4 mΩ
Terminal capacity Same as
main circuit DC Inductive circuit. DC-13 L/R ≤ 1 ms F
Electrical endurance 106 ops.

Tripping characteristics (AC)


G
AC AC-15
Electrical endurance
H
.
.
. I
.
.
.
.
. (1) 1 pole in series
X
. (2) 2 poles in series
(3) 3 poles in series
.

A.29
Series M
Electronic timer block
MREBC...
Rated insulation voltage (Ui) 750V
Rated thermal current (Ith) θ ≤ 60ºC (1) 0.55V
Standard voltages (AC y DC) 24 to 250V
Operation limits 0.80 to 1.1 Us
(0.85 to 1.1 Us at 12V)
Voltage drop < 3V
Auxiliary minicontactors

Maximum load current at


20ºC 0.9A
40ºC 0.72A
60ºC 0.55A
Minimum load for safe operation > 10 mA
Maximun current (peak) 10A for 40 ms
Leakage current at 220V < 5 mA
Operational current
AC-15 0.7A
DC-13 0.9A
Timing range (delay ON) 0.5 to 60 s (± 6 s)
Rearragement time < 100 ms
Repeatibility (accuracy) ±1%
Ambient temperature
Storage from –55 up to + 80ºC
Operation from –5 up to + 60ºC
Degree of protection IP20
Mounting position any
Terminals : 2 free cables 1 mm2 (AWG 17)

A 250 mm

B MREBC _ 0AC2

A.30

32764_A26_A44_E.indd 30 11-07-2005 15:34:47


Series M
Terminal numbering Auxiliary contact blocks.
According to EN 50005 & EN 50011
Auxiliary contactors. According to EN 50011
MARL110A _ MARL101A _ MARL110A _ S
MCR_040_ _ _ MCR_031_ _ _

MARL101A _ S MARN220A _ MARN211A _


MCR_022_ _ _ MCR_013_ _ _

Technical data
MARN202A _ MARN440A _ MARN431A _
MCR_004_ _ _

MARN422A _ MARN413A _ MARN404A _

B
Transient voltage suppressor block
C
MP0AAE _ MP0CAE3

MP0DAE4 E

A.31

32764_A26_A44_E.indd 31 11-07-2005 15:34:48


Series M
Terminal numbering in accordance with EN 50011
By combining other basic auxiliary contactors with auxiliary contact blocks MAR..., it is possible to obtain other combinations, and positions of
contacts which are not covered by the table. But in all cases the maximum number of auxiliary contacts should be ten.
Type E
Standard contact combination in
which the interchangeability of the
devices does not affect the cabling
or the diagram. Specifies a particular
contact numbering and positioning.
Auxiliary minicontactors

Final structure of Auxiliary contacts Auxiliary contactor


the combination Combination + Auxiliary contact blocks to be added

Description NO NC
Type E MCRA040A..
40E 4 0

31E 3 1 MCRA031A..

22E 2 2 MCRA022A..

13E 1 3 MCRA013A..

MCRA004A..
A 04E 0 4

MCRA040A..
60E 6 0
+ MARN220A..
B
MCRA040A..
51E 5 1
+ MARN211A..

C 42E 4 2
MCRA040A..
+ MARN202A..

MCRA040A..
80E 8 0
D + MARN440A..

MCRA040A..
71E 7 1
+ MARN431A..

E MCRA040A..
62E 6 2
+ MARN422A..

F 53E 5 3
MCRA040A..
+ MARN413A..

MCRA040A..
44E 4 4
+ MARN404A..
G
MCRA040A..
50E 5 0
+ MARL110A..

H 41E 4 1
MCRA031A..
+ MARL110A..

MCRA022A..
32E 3 2
I + MARL110A..

MCRA013A..
23E 2 3
+ MARL110A..

X MCRA013A..
14E 1 4
+ MARL101A..

MCRA004A..
05E 0 5
+ MARL101A..

A.32
Series M
Terminal numbering in accordance with EN 50011 (continued)
By combining other basic auxiliary contactors with auxiliary contact blocks MAR..., it is possible to obtain other combinations, and positions of
contacts which are not covered by the table. But in all cases the maximum number of auxiliary contacts should be ten.
Type Z Type X Type Y
Contact combination the same as Contact combination the same as Contact combination which differs
Type E. Interchangeability of the de- Type E. Interchangeability of the de- from Type E, although it is obtained
vices may affect the cabling and the vices may affect the cabling but not by a combination of devices provi-
diagram. Neither contact numbering the diagram.The contact numbering is ded for this Type E.
nor positioning are retained. maintained but not their position.

Final structure of Auxiliary contacts Auxiliary contactor


the combination Combination + Auxiliary contact blocks to be added

Description NO NC

Technical data
Type Z MCRA040A..
60Z 6 0
+ MARL110A.. + MARL110A..

51Z 5 1 MCRA040A..
+ MARL110A.. + MARL101A..

42Z 4 2 MCRA040A..
+ MARL101A.. + MARL101A..

MCRA040A..
100Z 10 0 + MARN440A.. + MARL110A..S
+ MARL110A..S
MCRA040A..
55Z 5 5 + MARN413A.. + MARL101A..S
+ MARL101A..S
A
Type X MCRA040A..
80X 8 0 + MARL110A.. + MARL110A..
+ MARL110A..S + MARL110A..S
MCRA040A..
B
71X 7 1 + MARL110A.. + MARL101A..
+ MARL110A..S + MARL110A..S

62X 6 2
MCRA040A..
+ MARL110A.. + MARL101A..
C
+ MARL101A..S + MARL110A..S
MCRA040A..
53X 5 3 + MARL110A.. + MARL101A..
+ MARL101A..S + MARL101A..S D
MCRA040A..
44X 4 4 + MARL101A.. + MARL101A..
+ MARL101A..S + MARL101A..S
MCRA040A.. E
91X 9 1 + MARN431A.. + MARL110A..S
+ MARL110A..S
MCRA040A..
82X 8 2 + MARN431A.. + MARL101A..S
+ MARL110A..S
F
MCRA040A..
73X 7 3 + MARN422A.. + MARL101A..S
+ MARL110A..S
MCRA040A..
G
64X 6 4 + MARN422A.. + MARL101A..S
+ MARL101A..S
Type Y
42Y 4 2
MCRA031A.. H
+ MARL110A.. + MARL101A..

MCRA022A..
33Y 3 3
+ MARL110A.. + MARL101A.. I
MCRA031A..
42Y 4 2
+ MARN211A..

MCRA022A..
X
33Y 3 3
+ MARN211A..

MCRA031A..
53Y 5 3
+ MARN422A..

MCRA022A..
44Y 4 4
+ MARN422A..

A.33
Series RL
General Mounting positions
Maximum number of contacts 4
Rated thermal current (Ith) θ < 55ºC 20A
Rated operational voltage (Ue) 690V
Insulation voltage (Ui) 1000V

Conformity to standards
IEC / EN 60947-1 IEC / EN 60947-5-1 ASE 1025
EN 50005 EN 50011 VDE 0660 / 102
NFC 63-110 NFC 63-140
Auxiliary contactors

CENELEC HD 410 CENELEC HD 420


NEMA ICS 1 CSA C22.2/14
UL 508 BS 4794 With the same pick-up and drop-out voltage
With the same rated power

Approvals
cULus DEMKO NEMKO
SEMKO FI
Lloyd’s Register Bureau Veritas
Control circuit
RL4RA... RL4RD... RL4RD...W

Ambient conditions Rated insulation voltage Ui (V) 1000 1000 1000


Standard voltages Us
Storage temperature -55ºC to +80ºC
50Hz (V) 24 ... 690 – –
Operation temperature -40ºC to +60ºC
60Hz (V) 24 ... 600 – –
Altitude up to 3000m Nominal values
DC (V) – 12 ... 440 12 ... 440
from 3000 to 4000m 90%Ie 80%Ue
Voltage (1)
A from 4000 to 5000m 80%Ie 75%Ue
Operating limits xUs 0.8 ... 1.1 0.8 ... 1.1 0.7 ... 1.3
Pick-up xUs 0.65 ... 0.75 0.45 ... 0.65 0.45 ... 0.55
Seal xUs 0.4 ... 0.55 0.15 ... 0.3 0.15 ... 0.3
Climatic resistance (IEC 68-2) Consumption
B Continuous tests 40 / 125 / 56 AC Magnetic circuit closed (VA) 6 – –
Cold (72h) Magnetic circuit open (VA) 45 – –
Temperature -40ºC DC Magnetic circuit closed (W) – 5.5 6.5
Dry heat (96h) Magnetic circuit open (W) – 5.5 6.5
C Temperature +125ºC Power dissipation (W) 2.4 5.5 6.5
Relative humidity < 50% Power factor
Humid heat (56 days) Magnetic circuit closed cos ϕ 0.34 – –
Temperature +40ºC Magnetic circuit open cos ϕ 0.82 – –
D Relative humidity 95% Opening and closing times
Cyclical tests (6 cycles) at 0,8 to 1,1 Us
Humid heat Making time at energisation NO (ms) 6 ... 25 35 ... 65 25 ... 65
First half-cycle (12h) Breaking time at de-energ. NO (ms) 6 ... 13 6 ... 13 6 ... 13
E Low temperature
Relative humidity
+25ºC
93%
at Us
Making time at energisation NO (ms) 8 ... 20 35 ... 45 25 ... 55
Second half-cycle (12h) Breaking time at de-energ. NO (ms) 6 ... 13 7 ... 12 6 ... 13
Low temperature +55ºC Mechanical endurance #106 ops 15 15 15

F Relative humidity 95% Maximum rate no load # ops./h 9000 3600 3600

Contact sequence (distance in mm)


G

Auxiliary contact
H NO
Auxiliary contact
NC

0 3.35 0 1.3
I Auxiliary RL4R......◆
contactor
0 1.85 0 2.8
RL4R...G◆
X
0 3.3 0 1.3 Open
Auxiliary BC_F.../
contact BRLL...
blocks
0 1.8 0 2.8
BCLF...G
Closed

A.34
Series RL
Internal auxiliary contacts Instantaneous auxiliary contact blocks
RL4..... BCLF../BCRF../BRLL..

Rated insulation voltage (Ui) acc. IEC 60947-5 1000V Rated insulation voltage (Ui) acc. IEC 60947-5 1000V
Rated thermal current (Ith) < 55ºC 20A Rated thermal current (Ith) θ < 55ºC 10A
Making capacity (r.m.s.) acc. IEC 60947-5 Making capacity (r.m.s.) acc. IEC 60947-5
AC-15 Ue ≤ 400V, 50/60 Hz 250A AC-15 Ue ≤ 440V, 50/60 Hz 90A
DC-13 Ue ≤ 220V DC 250A DC-13 Ue ≤ 220V DC 90A
Breaking capacity (r.m.s.) acc. IEC 60947-5 Breaking capacity (r.m.s.) acc. IEC 60947-5
AC-15 Ue ≤ 400V, 50/60 Hz 250A AC-15 Ue ≤ 400V, 50/60 Hz 60A
DC-13 Ue ≤ 220V DC 2A (4A with 2 DC-13 Ue ≤ 220V DC 0,95A
contacts in series Rated voltage and rated current Ue-Ie
Ue ≤ 110V DC 7A (12A with 2 AC-15 according to IEC 110/120V - 6A
contacts in series) 220/240V - 6A
Ue ≤ 48V DC 10A (18A with 2 380/400V - 4A
contacts in series) 415/440V - 3.5A

Technical data
Rated voltage and rated current Ue-Ie 500V - 2.5A
AC-15 according to IEC 110/120V - 10A 660/690V - 1.5A
220/240V - 10A according to UL, CSA A600
380/400V - 6A DC-13 24V - 4A
415/440V - 5A 48V - 2A
500V - 4A 110V - 0.7A
660/690V - 2A 220V - 0.3A
according to UL, CSA A600 415/440V - 0.15A
DC-13 according to IEC 24V - 6A according to UL, CSA Q600
48V - 4 A Electrical endurance 1 x 106 ops.
110V - 2A Minimum operational voltage (operational safety) 17V
220V - 0,7A Minimun operational current 5mA
440V - 0,35A Short-circuit protection (without welding) gL 10A
according to UL, CSA P600 Insulation resistance
A
Electrical endurance 1 x 106 ops. between contacts > 10 mΩ
Minimum operational voltage (operational safety) 17V between contacts and earth > 10 mΩ
Minimun operational current 5mA between input and output > 10 mΩ
Short-circuit protection Guaranteed no overlap between NO and NC contacts B
max. fus. class gL fuse 20A Space 1.3 mm
without welding 10A minimum time 1.5 ms
Insulation resistance Impedance of the contacts 1.28 mΩ
between contacts > 10 mΩ C
between contacts and earth > 10 mΩ
between input and output > 10 mΩ Terminal capacity
Guaranteed no overlap between NO and NC contacts
Solid, stranded and finely stranded mm2 2 x 0.5 to 2.5
space 1.3 mm
without end sleeve 2 x 2.5 to 4 D
minimum time 1.5 ms
Finely stranded with end sleeve mm2 2 x 0.5 to 2.5
Impedance 1.28 mΩ
2 x 2.5 to 4
AWG wires, solid and stranded mm2 2 x 20 to 10

Terminal capacity Tightening torque 0.8 Nm / 7 Lb.in E


Ring terminals 0.8 Nm / 7 Lb.in
Solid, stranded and finely stranded mm2 2 x 0.5 to 6
without end sleeve
.
Finely stranded with end sleeve mm2 2 x 1 to 6 F
AWG wires, solid and stranded mm2 2 x 20 to 12
Tightening torque 1.1 Nm / 10 Lb.in
Ring terminals 1.6 Nm / 15 Lb.in .

. G

A.35
Series RL
Timed auxiliary contact blocks Mechanical latch blocks
BTLF... / BTRF... RMLF.....
Rated insulation voltage (Ui) acc. IEC 60947-5 1000V Rated insulation voltage(Ui) 1000V
Rated thermal current (Ith) θ < 55ºC 10A Standard voltages (Us); 50-60Hz and direct current 24 ... 690V
Making capacity (r.m.s.) acc. IEC 60947-5 Operating limits 0.75 to 1.1 xUs
AC-15 Ue ≤ 440V, 50/60 Hz 90A Consumption for unlatching (auto cut-out) 210W /VA (24-72V)
DC-13 Ue ≤ 220V DC 90A 130W /VA (110-440V)
Breaking capacity (r.m.s.) acc. IEC 60947-5 Unlatching control (1)
AC-15 Ue ≤ 400V, 50/60 Hz 60A Electrical Min.impuls 10 ms
DC-13 Ue ≤ 220V DC 0,95A Maintained auto
Rated voltage and rated current Ue-Ie cut-out by integral
Auxiliary contactors

AC-15 according to IEC 110/120V - 6A contact 55-56


220/240V - 6A (only AC slots)
380/400V - 4A
415/440V - 3.5A Manual By local (0)
500V - 2.5A push-button
660/690V - 1.5A Contactor control
according to UL, CSA A600 Electrical Min.impuls 40 ms
DC-13 according to IEC 24V - 4A Manual By local (I)
48V - 2A push-button
110V - 0.7A Mechanicendurance CL00 ... CL45 3 x 106 (1200ops./h)
220V - 0.3A CL05 ... CL10 0.1 x 106 (300 ops./h)
415/440V - 0.15A
according to UL, CSA Q600
Electrical endurance 1 x 106 ops. Terminal capacity
Minimum operational voltage (operational safety) 17V
Minimum operational current 5mA Solid, stranded and finely stranded mm2 2 x 0.5 to 2.5
without end sleeve 2 x 2.5 to 4
A Short-circuit protection (without welding) gL
Insulation resistance
10A
Finely stranded with end sleeve mm2 2 x 0.5 to 2.5
between contacts > 10 MΩ 2 x 2.5 to 4
between contacts and earth > 10 MΩ AWG wires, solid and stranded mm2 2 x 20 to 10
between input and output > 10 MΩ Tightening torque 0,8 Nm / 7 Lb.in
B Guaranteed no overlap between NO and NC contacts
space 1,3 mm
minimum time 1,5 ms Terminal numbering
Timing
C (Ambient temperature between – 25 and + 55ºC)
Accuracy ±5% Auxiliary contactors
Loss of accuracy after 0,5 x 106 ops. + 20 %
Loss of accuracy per rise ºC (0 - 55ºC) + 0.75 % per ºC RL4R_040_ _ RL4R_031_ _
D Impedance of the contacts
Mechanical endurance
1.28 mΩ
5 x 106 ops.
Peak current
during 1 s. 50A
E during 0,1 s. 100A

Terminal capacity RL4R_022_ _ RL4R_004_ _


F Solid, stranded and finely stranded (mm )
2
2 x 0.5 to 2.5
without end sleeve 2 x 2.5 to 4
Finely stranded with end sleeve (mm2) 2 x 0.5 to 2.5
2 x 2.5 to 4
G AWG wires, solid and stranded
Tightening torque
(mm2) 2 x 20 to 10
0,8 Nm / 7 Lb.in
Ring terminals 0,8 Nm / 7 Lb.in
RL4R_022G_
.
H

I .

A.36

32764_A26_A44_E.indd 36 11-07-2005 15:35:11


Series RL

Auxiliary contact blocks. Front mounting Voltage suppressor blocks


BC_F10 BC_F01 BCLF10G BCLF01G BSLR2 BSLDZ BSLV3

Auxiliary contact blocks. Lateral mounting Voltage suppressor blocks to use


BRLL20 BRLL11
with interface modules and electro-
nic timer blocks

Technical data
IMRC IMD1Z IMV3

Pneumatic timer blocks


BT_F_C BT_F_D
Interface modules
IMRD, IMRG IMSSD
A

B
Electronic timer blocks
C
BETL_ _C BETL_ _D

D
IMRFD, IMRFG IMAMS

E
Mechanical (-/electrical) interlock
BELA, BEL BELA02, BEL02 F

H
Mechanical latch block
RMLF
AC AC/DC
I

A.37

32764_A26_A44_E.indd 37 11-07-2005 15:35:13


Series RL
Terminal numbering in accordance with EN 50011
By combining other basic auxiliary contactors with auxiliary contact blocks BLC..., it is possible to obtain other combinations, and positions of
contacts which are not covered by the table. But in all cases the maximum number of auxiliary contacts should be four.
Type E
Standard contact combination in
which the interchangeability of the
devices does not affect the cabling
or the diagram. Specifies a particular
contact numbering and positioning.

Final structure of Auxiliary contacts Auxiliary contactor


Auxiliary contactors

the combination Combination +Auxiliary contact blocks to be added

Description NO NC
Type E RL4RA040...
40E 4 0

31E 3 1 RL4RA031...

22E 2 2 RL4RA022...

04E 0 4 RL4RA004...

RL4RA040...
A 50E 5 0
+ BC_F10

RL4RA031...
41E 4 1
+ BC_F10
B
RL4RA022...
32E 3 2
+ BC_F10

C 23E 2 3
RL4RA022...
+ BC_F01

RL4RA004...
14E 1 4
D + BC_F10

05E 0 5 RL4RA004...
+ BC_F01

E RL4RA040...
60E 6 0
+ BC_F10 + BC_F10

RL4RA040...
F 51E 5 1
+ BC_F10 + BC_F01

RL4RA040...
42E 4 2
+ BC_F01 + BC_F01
G RL4RA040...
80E 8 0 + BC_F10 + BC_F10
+ BC_F10 + BC_F10

H 71E 7 1
RL4RA040...
+ BC_F10 + BC_F01
+ BC_F10 + BC_F10
RL4RA040...
62E 6 2 + BC_F10 + BC_F01
I + BC_F01 + BC_F10
RL4RA040...
53E 5 3 + BC_F10 + BC_F01
+ BC_F01 + BC_F01
X RL4RA040...
44E 4 4 + BC_F01 + BC_F01
+ BC_F01 + BC_F01

A.38
Series RL
Terminal numbering in accordance with EN 50011
By combining other basic auxiliary contactors with auxiliary contact blocks BLC..., it is possible to obtain other combinations, and positions of contacts which
are not covered by the table. But in all cases the maximum number of auxiliary contacts should be four.
Type Z Type Y
Contact combination the same as Contact combination which differs
Type E. from Type E, although it is obtained
Interchangeability of the devices by a combination of devices provi-
may affect the cabling and the di- ded for this Type E.
agram. Neither contact numbering
nor positioning are retained.

Final structure of Auxiliary contacts Auxiliary contactor


the combination Combination +Auxiliary contact blocks to be added

Description NO NC

Technical data
Type Z RL4RA040...
60Z 6 0
+ BRLL20

51Z 5 1 RL4RA040...
+ BRLL11

80Z 8 0 RL4RA040...
+ BRLL20 + BRLL20

RL4RA040...
71Z 7 1
+ BRLL11 + BRLL20

RL4RA040...
62Z 6 2
+ BRLL11 + BRLL11 A
Type Y RL4RA031...
42Y 4 2
+ BC_F10 + BC_F01
B

42Y 4 2
RL4RA031...
+ BRLL11
C

D
RL4RA031...
53Y 5 3 + BC_F10 + BC_F01
+ BC_F01 + BC_F10
RL4RA022... E
44Y 4 4 + BC_F10 + BC_F01
+ BC_F01 + BC_F10

33Y 3 3 RL4RA022...
+ BC_F10 + BC_F01 F

G
33Y 3 3 RL4RA022...
+ BRLL11

H
RL4RA040...
+ BTLF...C + BRLL20 I
RL4RA040...
+ BTLF...D + BRLL20

RL4RA040...
X
+ BTLF...C + BRLL11

RL4RA040...
+ BTLF...D + BRLL11

A.39
Series M
Dimensional drawings
Auxiliary minicontactors Auxiliary contact blocks. Front mounting
Slotted screw MCRC_ _ _ AT◆ 0.210 kg Slotted screw
MCRI _ _ _ ATD 0.225 kg
MCRA_ _ _ AT◆ 0.170 kg MCRK_ _ _ ATD 0.225 kg MARN2 _ _AT 0.025 kg
MARN4 _ _AT 0.040 kg
Auxiliary minicontactors

.
.
. . .

Ring terminal Ring terminal


MCRA_ _ _ AR◆ 0.170 kg MCRC_ _ _ AR◆ 0.210 kg MARN2 _ _AR 0.025 kg
MARN4 _ _AR 0.040 kg

A . . .

B
Terminal: Faston 2x2.8 insulated Terminal: Faston 2x2.8 insulated
C MCRA_ _ _ AF◆ 0.165 kg MCRC_ _ _ AF◆ 0.210 kg MARF4 _ _AF 0.035 kg

D
.

. . .
E

F
Terminal: Printed circuit
MCRA_ _ _ A I◆ 0.165 kg MCRC_ _ _ A I◆ 0.210 kg
. .
G . . . .
.

. . . .
I
.
.

A.40
Series M

Auxiliary contact blocks. Lateral mounting Electronic timer block


Slotted screw MREBC _0AC2 0.040 kg

MARL_ _ _AT, 0.013 kg


. .
. .

(1) AC-control. (1) Frontal mounting


(2) DC-control (2) Lateral mounting

Dimensions
Voltage suppressor block
Ring terminal
MARL_ _ _AR, ARS 0.013 kg MP0A_AE_ 0.010 kg
MP0C_AE3 0.010 kg

.
.

.
(1) AC-control.
(2) DC-control
B
Terminal: Faston 2x2.8 insulated
MARL _ _AF, AFS 0.009 kg C
.

D
.

(1) AC-control.
E
(2) DC-control

Terminal: Printed circuit


F
MARL _ _AI, AIS 0.009 kg

G
. .

H
.

(1) AC-control
(2) DC-control I

A.41
Series RL
Dimensional drawings
Auxiliary contactors Instantaneous auxiliary contact blocks
Screw terminal Screw terminal
AC Instantaneous, frontal
RL4RA_ _ _ T◆ 0.280 kg BCLF_ _ _ 0.015 kg

. 10.3 29
Auxiliary contactors

44.5
.

Ring terminal Instantaneous, lateral mounting


AC BRLL_ _ _ 0.048 kg
RL4RA_ _ _ R◆ 0.280 kg

.
.
A
.

B
.

C
DC Terminal: Ring terminal
D RL4RD_ _ _ T◆ 0.490 kg
frontal mounting
BCRF_ _ _ 0.015 kg
.
E .

F
.

DC
H RL4RD_ _ _ R◆ 0.490 kg

I .

X
.

A.42
Series RL

Timed auxiliary contact blocks


Screw terminal Ring terminal
Front mounting Front mounting
BTLF_ _ _ 0.085 kg BTRF_ _ _ 0.085 kg

. .

Dimensions
Mechanical (-/electrical) interlock Mechanical latch block
BELA 0.025 kg RMLF_ _ 0.082 kg
BELA02 0.025 kg

Voltage suppressor blocks Electronic timer block C


BSLR2_ 0.020 kg BETL_ _ C 0.040 kg
BSLDZ_ 0.020 kg BETL_ _ D 0.040 kg
BSLV3_ 0.020 kg D

Interface G
IMR_ 0.060 kg
IMRF_ 0.050 kg
IMSSD 0.045 kg H
IMAMS 0.045 kg

A.43
Everything is
Motor protection devices

SFK - Motor protection circuit breaker


B.2 Order codes
B.3 Auxiliary contact blocks and auxiliary functions
B.4 Enclosures and accessories
B.5 Terminal numbering
B.6 Technical data Plug-in relays and Auxiliary contactors A
B.7 Dimensions
Motor protection devices B

SURION - Manual motor starter


Contactors and Thermal overload relays C
B.8 GPS1B... - Thermal and magnetic protection
B.10 GPS2B... - Thermal and magnetic protection
Motorstarters D
B.12 GPS1M... - Magnetic protection
B.14 GPS2M... - Magnetic protection
Control and signalling units E
B.16 Accessories
B.20 Enclosures
Electronic relays F
B.22 Technical data
B.26 Mounting possibilities of the auxiliaries
Limit switches G
B.28 Dimensions

Speed drive units H


SURION

Manual Motor Starters and Coordination tables Main switches I


see chapter D pages D2-D13

Numerical index X

under control B.1


Series SFK
Motor protection circuit breaker

• For thermal and magnetic protection of AC and DC motors


• Conformity to standards IEC 947-2, IEC 947-4-1 and VDE 0660
• Manual push-button operation
• Setting ranges from 0.1 to 25A at 690V AC and 220V DC
• Short-circuit capacity of 65kA up to setting range of 1.6-2.5A/400V
Motor protection devices

• Trip class 10
• Instant magnetic tripping (12 times the maximum operating current Ie)
• Single phase protection
Standards • Ambient temperature compensation between – 5° C and + 40° C
A IEC 947-2
• Internal and external accessories easy to mount
• Quick fixing on DIN rail EN 50022-35 and, with two screws,
IEC 947-4-1 on plate or wall
VDE 0660 • Terminals protected against accidental contacts (IP20)
B • Suitable for isolation ( ) and positive padlocking in open position
(IEC 947-1 § 7-1-6)
Approvals
C

UL CSA
D

E Motor protection circuit breakers


3-phase Magnetical Thermal tripping current Cat. no. Ref. no. Pack
motor AC3 tripping (setting range)
380/415V current Min. Max.
F kW A A A
0.02 1.9 0.1 0.16 SFK0A 120001 1/5
0.06 3.0 0.16 0.25 SFK0B 120002 1/5
0.06 / 0.0 9 4.8 0.25 0.4 SFK0C 120003 1/5
G 0.12 / 0.18
0.25
7.5
12
0.4
0.63
0.63
1
SFK0D
SFK0E
120004
120005
1/5
1/5
0.37 / 0.55 19 1 1.6 SFK0F 120006 1/5
0.75 30 1.6 2.5 SFK0G 120007 1/5
1.1 / 1.5 48 2.5 4 SFK0H 120008 1/5
H 2.2
3.7 / 4.0
75
120
4
6.3
6.3
10
SFK0I
SFK0J
120009
120010
1/5
1/5
5.5 / 7.5 190 10 16 SFK0K 120011 1/5
9.0 240 16 20 SFK0L 120012 1/5
11 / 12.5 300 20 25 SFK0M 120013 1/5
I Circuit breaker to protect transformers on request

B.2
Series SFK
Auxiliary contact blocks
Cat. no. Ref. no. Pack

Side mounting 1NO 1NC SFAL11N 120020 1

Motor protection circuit breaker


2NO SFAL20N 120021 1
1NO 1NC SFAL11D 120022 1
(advanced on closing)
2NO SFAL20D 120023 1
(advanced on closing)
For lower 1change-over SFAL11S 120027 1
energy levels PE + N conductor SFALPEN 264826 1
(G 4V, G 4mA)

Internal mounting 1NO 1NC SFAI11 120024 1


Switch trip 1NO SFAK10 120025 1
indicator-alarm 1NC SFAK01 120026 1

Coils for internal mounting


Cat. no. Ref. no. Pack

Minimum power Functioning range: 0.35Ue < U < 0.7Ue A


Manual reset
Dissipated power 2.2VA / 1W
110V / 50Hz 120V / 60Hz SFB0RJ 120034 1
220V / 50Hz 240V / 60Hz SFB0RN 120035 1
380V / 50Hz 440V / 60Hz SFB0RU 120036 1 B

C
Undervoltage release According to IEC204-1, DIN VDE 0113, INRS Art. L233-5
special for machinary A combination of a special undervoltage release
and auxiliary contact block SFAL20D
110V / 50Hz 120V / 60Hz SFB0RJM 107256 1 D
220V / 50Hz 240V / 60Hz SFB0RNM 120114 1
380V / 50Hz 440V / 60Hz SFB0RUM 120115 1

E
Shunt trip Functioning range: 0.7Ue < U < 1.2Ue
Manual reset
110V / 50Hz 120V / 60Hz SFB0AJ 120030 1 F
220V / 50Hz 240V / 60Hz SFB0AN 120031 1
380V / 50Hz 440V / 60Hz SFB0AU 120032 1

Current limiter H
Cat. no. Ref. no. Pack

Current limiter Combined with SFK.


Upgrades breaking capacity to 50kA/3~400V
Not available UL, CSA.
I
In = 32A SFVH03 243713 1

B.3
Series SFK
Enclosures
Cat. no. Ref. no. Pack

Surface mounting IP41-PG16 SFS04 120040 1


Conversion kit IP55 SFS0K2 120046 1
IP55-PG16 SFS05 120041 1

Surface enclosure to combine SFK0 IP41 SFM04 120044 1


and contactors Series M and CL IP65 SFM06 120045 1
Motor protection devices

IP41-M25 SFS04M 212558 1


IP65-M25 SFS05M 212559 1

Flush mounting IP41 SFE04 120042 1


Conversion kit IP55 SFE0K2 120047 1
IP55 SFE05 120043 1

Accessories for enclosures


Cat. no. Ref. no. Pack
A
Neutral connection For use with surface and flush mounting enclosures SFVN0 101369 1

C Padlocking device Up to 3 padlocks 6 - 8 mm SFVCD 120054 1

E
Emergency mushroom Impulse function SFPS0 120051 1
push-buttons IP55 Latched, pull to release SFPR0 120052 1
Key locked, turn to release SFPE0 120053 1
F Conversion kit IP55 for SFS04 SFS04K1 245217 1
Conversion kit IP55 for SFE04 SFE04K1 216604 1

G
Indicator lamps Green 110/120V GPELGAJ 101375 1
H for AC and DC Green 220/240V
Green 380/440V
GPELGAN
GPELGAU
101376
101377
1
1
Green 480/500V GPELGAX 101378 1
Green 600V GPELGAY 101379 1
Red 110/120V GPELRAJ 101380 1
I Red 220/240V
Red 380/440V
GPELRAN
GPELRAU
101381
101382
1
1
Red 480/500V GPELRAX 101383 1
Red 600V GPELRAY 101384 1
Transparent 110/120V GPELCAJ 101385 1
X Transparent 220/240V
Transparent 380/440V
GPELCAN
GPELCAU
101386
101387
1
1
Transparent 480/500V GPELCAX 101388 1
Transparent 600V GPELCAY 101389 1

B.4
Series SFK
Accessories for enclosures (continued)
Cat. no. Ref. no. Pack
Three phase

Motor protection circuit breaker


4 units Ui 690V / Ie 63A L = 207mm GPB104A 101392 2
busbar block 5 units Ui 690V / Ie 63A L = 261mm GPB105A 101393 2
Plastic cover for 3 unused terminals GPB1GA 101408 2

Supply block Ie = 63A Fully insulated SFVB8 254537 5

Terminal numbering
A
Motor protection circuit breaker Auxiliary contact blocks
SFK... Side mounting B
1/L1 3/L2 5/L3 SFAL11N SFAL20N SFAL11D
13 21
32 44 13 23
34 44 13 21
32 44
C

31 43 33 43
D
31 43
I> I> I>
14 22 14 24 14 22

2/T1 4/T2 6/T3


SFAL20D SFAL11S
13 23
34 44 14 12
PE
PE
N E

33 43
PE
PE
F
14 24 11 N

Internal mounting G
SFAI11 SFAK10 SFAK01

53 51 53 51
H

54 52 54 52
I

B.5
Series SFK
Technical data
General Mounting positions
Rated thermal current (Ith) at 40ºC 25A
Rated insulation voltage (Ui) 690V
Rated operational voltage (Ue) AC 690V, 40/60Hz
(see application diagram) DC 220V, with or without earth
Motor protection devices

Standards
IEC 947-2 IEC 947-4-1 VDE 0660

Approvals
UL CSA

Main circuit
Category AC3, DC4
Operational frequency limits 40 to 60 Hz Auxiliary contact blocks
Opening time aprox. 7 ms
SFAL SFAI - SFAK
Mechanical endurance 105 operations
Electrical endurance category AC3 105 operations Rated insulation voltage (Ui) 500V 500V
Maximum operating rate 40 operations/hour according VDE 0110
Total dissipated power at rated 6W Rated thermal current (Ith) 6A 6A
thermal current and hot state AC-15 Ue 230V 400V 500V 230V 400V 500V
Tripping characteristics Ie 3,5A 2A 1A 2A 1A 0,5A

A Thermal
Symmetrical overloads Class 10
DC-13 Ue
Ie
60V 110V 220V
1,5A 1A 0,5A
60V 110V 220V
0,7A 0,55A 0,25A
(see curve 1, tripping curves) Protective fuse gl 6A 6A
Asymmetrical overloads To IEC 947-4-1 Wiring capacity,
Flexible wire min. 2 x 0.75mm2 2 x 0.75mm2
B (phase failure)
Temperature compensation
(see curve 2, tripping curves)
– 5 to + 40ºC max. 2 x 2.5mm2 2 x 2.5mm2
Magnetic 12 x Ie Terminal type M3,5, Pozidriv, safety flange screws
(Ie = max. thermal setting value)
Shunt release 0.7 - 1.2 Ue 100% ED Wiring diagram
C Operating voltage limits 2.2 VA
Consumption AC 1W
DC 0.85 - 1.1 Ue 100% ED AC
Undervoltage release
D Operating voltage limits 0.75 - 0.35 Ue 3 phase 690V ~ 1 phase690V ~
Breaking voltage limits 2.2 VA L1 L2 L3 N L N
Consumption 1W
Wiring capacity
E Rigid wire min. 2 wires of 0,75mm2
max. 2 wires of 6mm2
Flexible wire min. 2 wires of 0,75mm2
max. 2 wires of 4mm2
F DC
Tripping curve 220V
L+ (-) L -(+)
2h

G
100
60
40
minutes

20
10
6
4

H 2
1
40
1

Application diagram for tooling machines


20
seconds

10
6
4
2
I 2
1
600
400
milliseconds

200
1/L1

3/L2

5/L3

100

X
60
40
20
10
6
4
D1

1 1.5 2 3 4 5 6 7 8 9 10 15 20 30

x max adjustable thermal current I> I> I> U<


D2
2/T1

4/T2

6/T3

1 Thermal trip, operating with 3-phases


2 Thermal differential trip (from cold) operating with 2-phases

B.6

32764_B01_B07_E.indd 6 11-07-2005 15:12:06


Series SFK
Short-circuit breaking capacity Icu/Ics according to IEC 947-2
230V AC / 220V DC (1) 400V AC 415V AC 500V AC 690V AC
Thermal 3ph Icu Ics Fuse 3ph Icu Ics Fuse 3ph Icu Ics Fuse 3ph Icu Ics Fuse 3ph Icu Ics Fuse

Motor protection circuit breaker


(2) (2) (2) (2) (2)
adjustment motor motor motor motor motor
AC3 AC3 AC3 AC3 AC3
(A) (kW) (kA) (kA) (A) (kW) (kA) (kA) (kW) (kA) (kA) (A) (kW) (kA) (kA) (A) (kW) (kA) (kA) (A)
0.1 - 0.16 – 65 65 (3) 0.02 65 65 (3) 0.02 65 65 (3) 0.04 65 65 (3) 0.06 42 42 (3)
0.16 - 0.25 – 65 65 (3) 0.06 65 65 (3) 0.06 65 65 (3) 0.06 65 65 (3) 0.12 42 42 (3)
0.25 - 0.4 0.06 65 65 (3) 0.09 65 65 (3) 0.12 65 65 (3) 0.12 65 65 (3) 0.18 42 42 (3)
0.4 - 0.63 0.09 65 65 (3) 0.12 65 65 (3) 0.18 65 65 (3) 0.25 65 65 (3) 0.37 42 42 (3)
0.63 - 1 0.12 65 65 (3) 0.25 65 65 (3) 0.25 65 65 (3) 0.37 65 65 (3) 0.75 1 1 20
1 - 1.6 0.25 65 65 (3) 0.55 65 65 (3) 0.55 65 65 (3) 0.75 65 65 (3) 1.1 1 1 20
1.6 - 2.5 0.37 65 65 (3) 0.75 65 65 (3) 0.75 10 5 25 1.1 3 1.5 25 1.5 1 0.5 20
2.5 - 4 0.75 65 65 (3) 1.5 10 (4) 5 (4) 35 1.5 10 5 35 2.2 3 1.5 35 3 1 0.5 25
4 - 6.3 1.1 65 37,5(4) (3) 2.2 10 (4) 5 (4) 50 2.2 10 5 50 3 3 1.5 50 4 1 0.5 35
6.3 - 10 2.2 10 (4) 5 (4) 80 4 4 (4) 2 (4) 80 4 4 2 80 5.5 3 1.5 50 7.5 1 0.5 35
10 - 16 4 6 (4) 3 (4) 80 7.5 4 (4) 2 (4) 80 7.5 3.5 1.75 80 9 3 1.5 63 11 1 0.5 35
16 - 20 5 6 (4) 3 (4) 80 9 4 (4) 2 (4) 80 9 2.5 1.25 80 11 1.5 0.75 63 15 1 0.5 50
20 - 25 5.5 6 (4) 3 (4) 80 11 4 (4) 2 (4) 80 12.5 2.5 1.25 80 15 1.5 0.75 63 22 1 0.5 50
Icu = Ultimate short-circuit breaking capacity (1) At 220V, t = 15 ms
Ics = Service short-circuit breaking capacity (2) Maximum value of the fuses when the presumed short circuit current
is higher than the breaking capacity of the device. Type D, slow or NH type gG/gL.
(3) No back-up fuse required to the Icu value
(4) 50 kA in combination with current limiter

Dimensional drawings
A
Motor protection circuit breaker Auxiliary contact block Current limiter
76 76
37
45 44 9 38
B
80 76.5
80 O 1 45 76.5 80 45 30
STOP START
30
C
M4
M4 45 47
82 66

D
Enclosures: surface mounting Enclosure to combine with contactor
PG16 or M25 110
40
16.5
E
Ø21
Ø4.5
50
F
150 230 130
0 1
120 Ø4.5
G
50
55 95 15 80 15 5.5
60
80 118.5 H
Enclosures: flush mounting
85 R4-6
I
max.6 M4

X
116-118

90-92

116
110

129 0 1
118

70-72 33-34
14 80 64
70-72

B.7
Surion

Thermal and magnetic protection

GPS1B
Motor protection devices

Standards/Approvals Characteristics
A IEC 60947-1, 60947-2, 60947-4-1 • Rocker and rotary handle operator
DIN VDE 0660T 100/101/102 • Thermal and magnetic protection
UL508/CSA - UL508/cULus • Standard and high breaking capacity
B Shipping approvals: Icu = 100kA G Ics = 100% Icu
Icu < 100kA G Ics min. 75% Icu
• Clear identification of the operation state (ON-OFF-tripped)
C RINA Bureau Lloyd’s Register • Ambient temperature compensation
Veritas Germanischer Lloyd • Phase failure protection

Auxiliaries
D

E Technical performances
Rated current In (A) 0.1-32
Rated operational current Ie (A) 0.1-32
F Rated power at 400Vac (kW) 0.02-15
Utilisation category
IEC 60947-2 (circuit breaker) A
IEC 60947-4-1 (MMS) AC-3
G Tripping class IEC 60947-4-1 10
Magnetic release Ie max. (A) x13
Mechanical/electrical endurance 100,000
H

I
Accessories
X Auxiliaries ! pg. B.16
Busbar system ! pg. B.19

Technical data ! pg. B.22


Dimensions ! pg. B.28
Fuseless starters ! pg. D.2
Busbar adapter plates ! pg. D.4
Coordination tables ! pg. D.5

B.8
Surion
GPS1B - Standard breaking capacity
CLASS 10 Rated power Rated current Thermal Instantaneous Rated Rated service Cat. no. Ref. no. Pack.
3 phase In current short-circuit ultimate short-circuit
motors at (1) setting range release short-circuit breaking
400Vac Pn breaking capacity at
capacity at 400V
400V
(kW) (A) (A) (A) Icu (kA) Ics (kA)

0.02 0.16 0.1 - 0.16 2.1 100 100 GPS1BSAA 101211 5


0.06 0.25 0.16 - 0.25 3.3 100 100 GPS1BSAB 101212 5
0.09 0.4 0.25 - 0.4 5.2 100 100 GPS1BSAC 101213 5

Manual motor starter


0.12/0.18 0.63 0.4 - 0.63 8.2 100 100 GPS1BSAD 101214 5
0.25 1 0.63 - 1 13 100 100 GPS1BSAE 101215 5
0.37/0.55 1.6 1 - 1.6 20.8 100 100 GPS1BSAF 101216 5
0.75 2.5 1.6 - 2.5 32.5 100 100 GPS1BSAG 101217 5
1.5 4 2.5 - 4 52 100 100 GPS1BSAH 101218 5
2.2 6.3 4 - 6.3 81.9 100 100 GPS1BSAJ 101219 5
3/4 10 6.3 - 10 130 100 100 GPS1BSAK 101220 5
5.5 13 9 - 13 169 50 38 GPS1BSAL 101221 5
7.5 16 11 - 16 208 25 19 GPS1BSAM 101222 5
10 20 14 - 20 260 25 19 GPS1BSAN 101223 5
11 25 19 - 25 325 25 19 GPS1BSAP 101224 5
15 32 24 - 32 416 25 19 GPS1BSAR 101225 5

0.02 0.16 0.1 - 0.16 2.1 100 100 GPS1BSAAMP 101195 40


0.06 0.25 0.16 - 0.25 3.3 100 100 GPS1BSABMP 101196 40
0.09 0.4 0.25 - 0.4 5.2 100 100 GPS1BSACMP 101197 40
0.12/0.18 0.63 0.4 - 0.63 8.2 100 100 GPS1BSADMP 101198 40
0.25 1 0.63 - 1 13 100 100 GPS1BSAEMP 101199 40
0.37/0.55 1.6 1 - 1.6 20.8 100 100 GPS1BSAFMP 101200 40
0.75 2.5 1.6 - 2.5 32.5 100 100 GPS1BSAGMP 101201 40
1.5
2.2
4
6.3
2.5 - 4
4 - 6.3
52
81.9
100
100
100
100
GPS1BSAHMP
GPS1BSAJMP
101202
101203
40
40
A
3/4 10 6.3 - 10 130 100 100 GPS1BSAKMP 101204 40
5.5 13 9 - 13 169 50 38 GPS1BSALMP 101205 40
7.5 16 11 - 16 208 25 19 GPS1BSAMMP 101206 40
10
11
20
25
14 - 20
19 - 25
260
325
25
25
19
19
GPS1BSANMP
GPS1BSAPMP
101207
101208
40
40
B
15 32 24 - 32 416 25 19 GPS1BSARMP 101209 40

(1) Rated current: highest thermal current setting range value.


C

GPS1B - High breaking capacity. D


CLASS 10 Rated power Rated Thermal Instantaneous Rated Rated service Cat. no. Ref. no. Pack.
3 phase current In current short-circuit ultimate short-circuit
motors at (1) setting range release short-circuit breaking
400Vac Pn breaking
capacity at
capacity at
400V
E
400V
(kW) (A) (A) (A) Icu (kA) Ics (kA)

0.02
0.06
0.16
0.25
0.1 - 0.16
0.16 - 0.25
2.1
3.3
100
100
100
100
GPS1BHAA
GPS1BHAB
101234
101235
5
5
F
0.09 0.4 0.25 - 0.4 5.2 100 100 GPS1BHAC 101236 5
0.12/0.18 0.63 0.4 - 0.63 8.2 100 100 GPS1BHAD 101237 5
0.25 1 0.63 - 1 13 100 100 GPS1BHAE 101238 5
0.37/0.55
0.75
1.6
2.5
1 - 1.6
1.6 - 2.5
20.8
32.5
100
100
100
100
GPS1BHAF
GPS1BHAG
101239
101240
5
5
G
1.5 4 2.5 - 4 52 100 100 GPS1BHAH 101241 5
2.2 6.3 4 - 6.3 81.9 100 100 GPS1BHAJ 101242 5
3/4 10 6.3 - 10 130 100 100 GPS1BHAK 101243 5
5.5
7.5
13
16
9 - 13
11 - 16
169
208
100
50
100
38
GPS1BHAL
GPS1BHAM
101244
101245
5
5
H
10 20 14 - 20 260 50 38 GPS1BHAN 101246 5
11 25 19 - 25 325 50 38 GPS1BHAP 101247 5
15 32 24 - 32 416 50 38 GPS1BHAR 101248 5
I
(1) Rated current: highest thermal current setting range value.

B.9
Surion

Thermal and magnetic protection

GPS2B
Motor protection devices

Standards/Approvals Characteristics
A IEC 60947-1, 60947-2, 60947-4-1 • Rotary handle operator
DIN VDE 0660T 100/101/102 • Thermal and magnetic protection
UL508/CSA - UL508/cULus • Standard and high breaking capacity
B Shipping approvals: Icu = 100kA G Ics = 100% Icu
Icu < 100kA G Ics min. 75% Icu
• Clear identification of the operation state (ON-OFF-tripped)
C RINA Bureau Lloyd’s Register • Ambient temperature compensation
Veritas Germanischer Lloyd • Phase failure protection

Auxiliaries
D

E Technical performances
Rated current In (A) 10-63
Rated operational current Ie (A) 10-63
F Rated power at 400Vac (kW) 4-30
Utilisation category
IEC 60947-2 (circuit breaker) A
IEC 60947-4-1 (MMS) AC-3
G Tripping class IEC 60947-4-1 10
Magnetic release Ie max. (A) x13
Mechanical/electrical endurance 50,000/25,000
H

I
Accessories
X Auxiliaries ! pg. B.16
Busbar system ! pg. B.19

Technical data ! pg. B.22


Dimensions ! pg. B.28
Fuseless starters ! pg. D.2
Busbar adapter plates ! pg. D.4
Coordination tables ! pg. D.5

B.10
Surion
GPS2B - Standard breaking capacity
CLASS 10 Rated Rated Thermal Instantaneous Rated Rated service Cat. no. Ref. no. Pack.
power current In current short-circuit ultimate short-circuit
3 phase (1) setting range release short-circuit breaking
motors at breaking capacity at
400Vac Pn capacity at 400V
400V
(kW) (A) (A) (A) Icu (kA) Ics (kA)

3/4 10 6.3 - 10 130 100 100 GPS2BSAK 101226 1


5.5 13 9 - 13 169 50 38 GPS2BSAL 107119 1
7.5 16 11 -16 208 25 19 GPS2BSAM 101227 1

Manual motor starter


10 20 14 - 20 260 25 19 GPS2BSAN 101228 1
11 25 19 - 25 325 25 19 GPS2BSAP 101229 1
15 32 24 - 32 416 25 19 GPS2BSAR 101230 1
18.5 40 28 - 40 520 25 19 GPS2BSAS 101231 1
22 50 35 - 50 650 25 19 GPS2BSAT 101232 1
30 63 45 - 63 819 25 19 GPS2BSAU 101233 1

(1) Rated current: highest thermal current setting range value.

GPS2B - High breaking capacity


CLASS 10 Rated power Rated Thermal Instantaneous Short-circuit Short-circuit Cat. no. Ref. no. Pack.
3 phase current In current short-circuit breaking breaking
motors at (1) setting range release capacity at capacity at A
400Vac Pn 400V 400V

(kW) (A) (A) (A) Icu (kA) Ics (kA)


B
3/4 10 6.3 - 10 130 100 100 GPS2BHAK 101249 1
5.5 13 9 - 13 169 100 100 GPS2BHAL 107120 1
7.5 16 11 -16 208 50 38 GPS2BHAM 101250 1
10 20 14 - 20 260 50 38 GPS2BHAN 101251 1
11 25 19 - 25 325 50 38 GPS2BHAP 101252 1 C
15 32 24 - 32 416 50 38 GPS2BHAR 101253 1
18.5 40 28 - 40 520 50 38 GPS2BHAS 101254 1
22 50 35 - 50 650 50 38 GPS2BHAT 101255 1
30 63 45 - 63 819 50 38 GPS2BHAU 101256 1
D

(1) Rated current: highest thermal current setting range value.


F

B.11
Surion

Magnetic protection

GPS1M
Motor protection devices

Standards/Approvals Characteristics
A IEC 60947-1, 60947-2, 60947-4-1 • Short-circuit protection for starters
DIN VDE 0660T 100/101/102 • Rocker and rotary handle operator
UL508/CSA - UL508/cULus • Magnetic protection
B Shipping approvals: • Standard and high breaking capacity
Icu = 100kA G Ics = 100% Icu
Icu < 100kA G Ics min. 75% Icu
C RINA Bureau Lloyd’s Register • Clear identification of the operation state (ON-OFF-tripped)
Veritas Germanischer Lloyd

Auxiliaries
D

E Technical performances
Rated current In (A) 0.1-32
Rated operational current Ie (A) 0.1-32
F Utilisation category
IEC 60947-2 (circuit breaker) A
Magnetic release Ie max. (A) x13
Mechanical/electrical endurance 100.000
G

I
Accessories
X Auxiliaries ! pg. B.16
Busbar system ! pg. B.19

Technical data ! pg. B.22


Dimensions ! pg. B.28
Fuseless starters ! pg. D.2
Busbar adapter plates ! pg. D.4
Coordination tables ! pg. D.5

B.12
Surion
GPS1M - Standard breaking capacity
Rated power Rated Thermal Instantaneous Rated Rated service Cat. no. Ref. no. Pack.
3 phase current In current short-circuit ultimate short-circuit
motors at setting range release short-circuit breaking
400Vac Pn (1) breaking capacity at
capacity at 400V
400V
(kW) (A) (A) (A) Icu (kA) Ics (kA)

0.02 0.16 - 2.1 100 100 GPS1MSAA 101257 5


0.06 0.25 - 3.3 100 100 GPS1MSAB 101258 5
0.09 0.4 - 5.2 100 100 GPS1MSAC 101259 5

Manual motor starter


0.12/0.18 0.63 - 8.2 100 100 GPS1MSAD 101260 5
0.25 1 - 13 100 100 GPS1MSAE 101261 5
0.37/0.55 1.6 - 20.8 100 100 GPS1MSAF 101262 5
0.75 2.5 - 32.5 100 100 GPS1MSAG 101263 5
1.5 4 - 52 100 100 GPS1MSAH 101264 5
2.2 6.3 - 81.9 100 100 GPS1MSAJ 101265 5
3/4 10 - 130 100 100 GPS1MSAK 101266 5
5.5 13 - 169 50 38 GPS1MSAL 101267 5
7.5 16 - 208 25 19 GPS1MSAM 101268 5
10 20 - 260 25 19 GPS1MSAN 101269 5
11 25 - 325 25 19 GPS1MSAP 101270 5
15 32 - 416 25 19 GPS1MSAR 101271 5

(1) Select appropriate thermal overload relay for the starter. See chapter C pages C.64 - C.68.

GPS1M - High breaking capacity


Rated power Rated current Thermal Instantaneous Rated Rated service Cat. no. Ref. no. Pack.
3 phase In current short-circuit ultimate short-circuit
motors at setting range release short-circuit breaking A
400Vac Pn (1) breaking capacity at
capacity at 400V
400V
(kW) (A) (A) (A) Icu (kA) Ics (kA)
B
0.02 0.16 - 2.1 100 100 GPS1MHAA 101280 5
0.06 0.25 - 3.3 100 100 GPS1MHAB 101281 5
0.09 0.4 - 5.2 100 100 GPS1MHAC 101282 5
0.12/0.18 0.63 - 8.2 100 100 GPS1MHAD 101283 5
0.25 1 - 13 100 100 GPS1MHAE 101284 5 C
0.37/0.55 1.6 - 20.8 100 100 GPS1MHAF 101285 5
0.75 2.5 - 32.5 100 100 GPS1MHAG 101286 5
1.5 4 - 52 100 100 GPS1MHAH 101287 5
2.2 6.3 - 81.9 100 100 GPS1MHAJ 101288 5
3/4 10 - 130 100 100 GPS1MHAK 101289 5 D
5.5 13 - 169 100 100 GPS1MHAL 101290 5
7.5 16 - 208 50 38 GPS1MHAM 101291 5
10 20 - 260 50 38 GPS1MHAN 101292 5
11 25 - 325 50 38 GPS1MHAP 101293 5
15 32 - 416 50 38 GPS1MHAR 101294 5 E

(1) Select appropriate thermal overload relay for the starter. See chapter C pages C.64 - C.68.
F

B.13
Surion

Magnetic protection

GPS2M
Motor protection devices

Standards/Approvals Characteristics
A IEC 60947-1, 60947-2, 60947-4-1 • Short-circuit protection for starters
DIN VDE 0660T 100/101/102 • Rotary handle operator
UL508/CSA - UL508/cULus • Magnetic protection
B Shipping approvals: • Standard and high breaking capacity
Icu = 100kA G Ics = 100% Icu
Icu < 100kA G Ics min. 75% Icu
C RINA Bureau Lloyd’s Register • Clear identification of the operation state (ON-OFF-tripped)
Veritas Germanischer Lloyd

Auxiliaries
D

E Technical performances
Rated current In (A) 10-63
Rated operational current Ie (A) 10-63
F Utilisation category
IEC 60947-2 (circuit breaker) A
Magnetic release Ie max. (A) x13
Mechanical/electrical endurance 50,000/25,000
G

I
Accessories
X Auxiliaries ! pg. B.16
Busbar system ! pg. B.19

Technical data ! pg. B.22


Dimensions ! pg. B.28
Fuseless starters ! pg. D.2
Busbar adapter plates ! pg. D.4
Coordination tables ! pg. D.5

B.14
Surion
GPS2M - Standard breaking capacity
Rated power Rated Thermal Instantaneous Rated Rated service Cat. no. Ref. no. Pack.
3 phase current In current short-circuit ultimate short-circuit
motors at setting range release short-circuit breaking
400Vac Pn (1) breaking capacity at
capacity at 400V
400V
(kW) (A) (A) (A) Icu (kA) Ics (kA)

4 10 - 130 100 100 GPS2MSAK 101272 1


5.5 13 - 169 50 38 GPS2MSAL 107121 1
7.5 16 - 208 25 19 GPS2MSAM 101273 1

Manual motor starter


10 20 - 260 25 19 GPS2MSAN 101274 1
11 25 - 325 25 19 GPS2MSAP 101275 1
15 32 - 416 25 19 GPS2MSAR 101276 1
18.5 40 - 520 25 19 GPS2MSAS 101277 1
22 50 - 650 25 19 GPS2MSAT 101278 1
30 63 - 819 25 19 GPS2MSAU 101279 1

(1) Select appropriate thermal overload relay for the starter. See chapter C pages C.64 - C.68.

GPS2M - High breaking capacity


Rated power Rated Thermal Instantaneous Rated Rated service Cat. no. Ref. no. Pack.
3 phase current In current short-circuit ultimate short-circuit
motors at setting range release short-circuit breaking A
400Vac Pn (1) breaking capacity at
capacity at 400V
400V
(kW) (A) (A) (A) Icu (kA) Ics (kA)
B
4 10 - 130 100 100 GPS2MHAK 101295 1
5.5 13 - 169 100 100 GPS2MHAL 107122 1
7.5 16 - 208 50 38 GPS2MHAM 101296 1
10 20 - 260 50 38 GPS2MHAN 101297 1
11 25 - 325 50 38 GPS2MHAP 101298 1 C
15 32 - 416 50 38 GPS2MHAR 101299 1
18.5 40 - 520 50 38 GPS2MHAS 101300 1
22 50 - 650 50 38 GPS2MHAT 101301 1
30 63 - 819 50 38 GPS2MHAU 101302 1
D

(1) Select appropriate thermal overload relay for the starter. See chapter C pages C.64 - C.68.
F

B.15
Surion

Auxiliaries
Motor protection devices

Standards/Approvals Product range


A IEC 60947-1, 60947-2, 60947-4-1 • Auxiliary contacts (frontal & lateral)
DIN VDE 0660T 100/101/102 • Alarm contact block
UL508/CSA - UL508/cULus • Auxiliary and alarm contact block
B Shipping approvals: • Short-circuit alarm contact block
• Shunt trip
• Undervoltage release
C RINA Bureau Lloyd’s Register • Undervoltage release with 2NO early make contacts
Veritas Germanischer Lloyd • External handle operator
• Terminal protector
Auxiliaries • Busbar system
D

E
Technical performances
F • All auxiliaries can be mounted and changed easily,
without any tools
• Both frames GPS1 and GPS2 uses same auxiliaries
G • All terminals are capable for 2 cables (0.5mm2 - 2.5mm2)
• Side auxiliary contacts are rated to A600, P300 duty
• Frontal auxiliary contacts are rated to B300, Q300 duty
• Minimum operational contact 5mA, 17Vdc
H • All terminal screwhead are Pozidriv 2 and slotted combination

I
Accessories
X Auxiliaries ! pg. B.16
Busbar system ! pg. B.19

Technical data ! pg. B.22


Dimensions ! pg. B.28
Fuseless starters ! pg. D.2
Busbar adapter plates ! pg. D.4
Coordination tables ! pg. D.5

B.16
Surion
Auxiliary contact blocks
Description For use with Type Cat. no. Ref. no. Pack.

Frontal Maximum 2 auxiliary contact GPS1... and GPS2... 1 NO GPAC10FBA 101303 10


blocks per manual motor starter GPS1... and GPS2... 1 NC GPAC01FBA 101304 10

Manual motor starter


Lateral Two contacts GPS1... and GPS2... 1 NO + 1 NC GPAC11LLA 101305 10
Side mounting on the left GPS1... and GPS2... 2 NO GPAC20LLA 101306 10
GPS1... and GPS2... 2 NC GPAC02LLA 101307 10

Two contacts GPS1... and GPS2... 1 NO + 1 NC GPAC11LRA 101308 10


Side mounting on the right GPS1... and GPS2... 2 NO GPAC20LRA 101309 10
GPS1... and GPS2... 2 NC GPAC02LRA 101310 10

A
Alarm contact block
Description For use with Type Cat. no. Ref. no. Pack.

Frontal mounting on the right GPS1... and GPS2... 1 NO GPAL10FRA 101311 10


B
Single contact GPS1... and GPS2... 1 NC GPAL01FRA 101312 10

D
Auxiliary / alarm contact block
Description For use with Type Cat. no. Ref. no. Pack. E
Side mounting on the left (front GPS1... and GPS2... 1 NO(Alarm)+1 NO(Aux.) GPAD1010LLA 101313 10
alarm contact block can not be GPS1... and GPS2... 1 NO(Alarm)+1 NC(Aux.) GPAD1001LLA 101314 10
used at the same time) GPS1... and GPS2... 1 NC(Alarm)+1 NO(Aux.) GPAD0110LLA 101315 10 F
Two contacts GPS1... and GPS2... 1 NC(Alarm)+1 NC(Aux.) GPAD0101LLA 101316 10

Short-circuit alarm contact block H


Description For use with Type Cat. no. Ref. no. Pack.

Side mounting on the left GPS1... and GPS2... 1 NO + 1 NC GPAE11LLA 101317 10 I


Two contacts NO + NC
Mechanical indication marking

B.17
Surion
Shunt trip device
Description For use with Coil voltage Cat. no. Ref. no. Pack.

Side mounting on the right GPS1... and GPS2... 24V 50/60Hz GPASLRAA1 101318 5
Can not be used together with GPS1... and GPS2... 48V 60Hz GPASLRAAF 101319 5
the undervoltage trip device GPS1... and GPS2... 48V 50Hz / 60V 60Hz GPASLRAAG 101320 5
GPS1... and GPS2... 110/127V 50Hz / 120V 60Hz GPASLRAAJ 101321 5
GPS1... and GPS2... 208V 60Hz GPASLRAAM 101322 5
Motor protection devices

GPS1... and GPS2... 220/230V 50Hz / 240/260V 60Hz GPASLRAAN 101323 5


GPS1... and GPS2... 240V 50Hz / 277V 60Hz GPASLRAAR 101324 5
GPS1... and GPS2... 380/400V 50Hz GPASLRAAU 101325 5
GPS1... and GPS2... 415/440V 50Hz / 460/480V 60Hz GPASLRAAW 101326 5
GPS1... and GPS2... 500V 50Hz / 600V 60Hz GPASLRAAY 101327 5
GPS1... and GPS2... 24 to 60Vdc GPASLRADD 101328 5
GPS1... and GPS2... 110 to 240Vdc GPASLRADJ 101329 5
GPS1... and GPS2... 100V 50/60Hz GPASLRAA11 101194 5

Undervoltage trip device


Description For use with Coil voltage Cat. no. Ref. no. Pack.

Side mounting on the right GPS1... and GPS2... 24V 50Hz GPAULRAAD 101330 5
Can not be used together with GPS1... and GPS2... 24V 60Hz GPAULRAAC 101331 5
the shunt trip device GPS1... and GPS2... 48V 50Hz GPAULRAAG 101332 5
GPS1... and GPS2... 48V 60Hz GPAULRAAF 101333 5
GPS1... and GPS2... 110/127V 50Hz / 120V 60Hz GPAULRAAJ 101334 5
GPS1... and GPS2... 208V 60Hz GPAULRAAM 101335 5
GPS1... and GPS2... 220/230V 50Hz / 240/260V 60Hz GPAULRAAN 101336 5
GPS1... and GPS2... 240V 50Hz / 277V 60Hz GPAULRAAR 101337 5
A GPS1... and GPS2... 380/400V 50Hz GPAULRAAU
GPS1... and GPS2... 415/440V 50Hz / 460/480V 60Hz GPAULRAAW
101338
101339
5
5
GPS1... and GPS2... 500V 50Hz / 600V 60Hz GPAULRAAY 101340 5
GPS1... and GPS2... 100V 50/60Hz GPAULRAA11 102625 5

B With 2NO Side mounting on the right GPS1*S... 24V 50Hz GPAU20LTAAD 101341 5
early make Can not be used together with GPS1*S... 24V 60Hz GPAU20LTAAC 101342 5
auxiliary contacts the shunt trip device GPS1*S... 48V 50Hz GPAU20LTAAG 101343 5
GPS1*S... 48V 60Hz GPAU20LTAAF 101344 5
C GPS1*S...
GPS1*S...
110/127V 50Hz / 120V 60Hz GPAU20LTAAJ
208V 60Hz GPAU20LTAAM
101345
101346
5
5
GPS1*S... 220/230V 50Hz / 240/260V 60Hz GPAU20LTAAN 101347 5
GPS1*S... 240V 50Hz / 277V 60Hz GPAU20LTAAR 101348 5
GPS1*S... 380/400V 50Hz GPAU20LTAAU 101349 5
D GPS1*S...
GPS1*S...
415/440V 50Hz / 460/480V 60Hz GPAU20LTAAW
500V 50Hz / 600V 60Hz GPAU20LTAAY
101350
101351
5
5
GPS1*S... 100V 50/60Hz GPAU20LTAA11 110360 5

E With 2NO
early make
Side mounting on the right
Can not be used together with
GPS1*H and GPS2...
GPS1*H and GPS2...
24V 50Hz
24V 60Hz
GPAU20LCAAD
GPAU20LCAAC
101352
101353
5
5
auxiliary contacts the shunt trip device GPS1*H and GPS2... 48V 50Hz GPAU20LCAAG 101354 5
GPS1*H and GPS2... 48V 60Hz GPAU20LCAAF 101355 5
GPS1*H and GPS2... 110/127V 50Hz / 120V 60Hz GPAU20LCAAJ 101356 5
F GPS1*H and GPS2... 208V 60Hz GPAU20LCAAM
GPS1*H and GPS2... 220/230V 50Hz / 240/260V 60Hz GPAU20LCAAN
101357
101358
5
5
GPS1*H and GPS2... 240V 50Hz / 277V 60Hz GPAU20LCAAR 101359 5
GPS1*H and GPS2... 380/400V 50Hz GPAU20LCAAU 101360 5
GPS1*H and GPS2... 415/440V 50Hz / 460/480V 60Hz GPAU20LCAAW 101361 5
G GPS1*H and GPS2... 500V 50Hz / 600V 60Hz
GPS1*H and GPS2... 100V 50/60Hz
GPAU20LCAAY
GPAU20LCAA11
101362
112185
5
5

H Terminal protector
Description For use with Cat. no. Ref. no. Pack.

I Snap-in tabs for screw mounting


(set of 10)
GPS1* GPAKS1A 101509 1

IP20 terminal covers GPS2* GPAPTP2A 107182 6

DIN rail vibration clamps GPS1* / GPS2* GPVDA 101514 2


X Panel vibration clamps GPS1* / GPS2* GPVPA 101515 2

Increases vibration resistance of GPS1* from 5G to 8G (5-150 Hz) in all directions.


One clamp must be mounted on each side which increases total mounting width
101509 107182 by 22 mm (0.87”).
For vibration resistance of GPS2*, contact customers service.

B.18
Surion
External handle operator
Description For use with Type Cat. no. Ref. no. Pack.

Used for distance mounting on a GPS1*H... Standard (black) GPA1HAB 101363 1


panel GPS1*H ... Emergency (red/yellow) GPA1HAR 101364 1
Lockable with 1, 2 or 3 padlocks GPS2... Standard (black) GPA2HAB 101502 1
diameter 4 to 8 mm GPS2 ... Emergency (red/yellow) GPA2HAR 101503 1
Two types: standard and emergency
applications
ON/OFF/TRIPPING position marking
Protection degree: IP54

Manual motor starter


Shaft mounting depths:
139.8 - 289.8 mm for GPA1HAB, GPA1HAR
161 - 311.1 mm for GPA2HAB, GPA2HAR
Package parts and quantities:
1 handle unit
1 shaft
1 shaft guide
1 latch (screws)
4 mounting screws

Busbar system
Description For use with Connection Cat. no. Ref. no. Pack.

3-phase feed-in Main feeding terminal GPS1... Terminal capacity: 25 mm2 GPB1FA 107186 5
terminals Upper connection Pin
GPS2... Terminal capacity: 50 mm2
Pin
GPB2FA 107187 5 A
GPS1... Terminal capacity: 25mm 2
SFVB8 254537 5
Fork
Main busbar Modular spacing 45 mm for 2 GPS1... + frontal auxiliaries Pin GPB1B02A 101390 2
63A max. for 3 GPS1... + frontal auxiliaries Pin GPB1B03A 101391 2 B
for 4 GPS1... + frontal auxiliaries Pin GPB1B04A 101392 2
for 5 GPS1... + frontal auxiliaries Pin GPB1B05A 101393 2

Modular spacing 54 mm for 2 GPS1... + 9mm lateral aux. Pin GPB1B12A 101394 2
for 3 GPS1... + 9mm lateral aux. Pin GPB1B13A 101395 2 C
for 4 GPS1... + 9mm lateral aux. Pin GPB1B14A 101396 2
for 5 GPS1... + 9mm lateral aux. Pin GPB1B15A 101397 2

Modular spacing 63 mm for 2 GPS1... + 18mm lateral aux. Fork GPB1B22A 101398 2
or 2 x 9mm lateral auxiliary D
for 4 GPS1... + 18mm lateral aux. Fork GPB1B24A 101399 2
or 2 x 9mm lateral auxiliary

125A max. Modular spacing 55 mm for 2 GPS2... + frontal auxiliaries Pin GPB2B02A 101400 2
for 3 GPS2... + frontal auxiliaries Pin GPB2B03A 101401 2 E
for 4 GPS2... + frontal auxiliaries Pin GPB2B04A 101402 2

Modular spacing 64 mm for 2 GPS2... + 9mm lateral aux. Pin GPB2B12A 101403 2
for 3 GPS2... + 9mm lateral aux. Pin GPB2B13A 101404 2
for 4 GPS2... + 9mm lateral aux. Pin GPB2B14A 101405 2 F
Modular spacing 73 mm for 2 GPS2... + 18mm lateral aux. Pin GPB2B22A 101406 2
or 2 x 9mm lateral auxiliary
for 4 GPS2... + 18mm lateral aux. Pin GPB2B24A 101407 2
or 2 x 9mm lateral auxiliary G
Busbar cover Touch guard for non GPS1... Pin GPB1GA 101408 2
used space GPS1... Fork GPB1GAF 101511 2
GPS2... Pin GPB2GA 101409 2 H
Terminal For compliance UL508E GPS1...H - GPAPT1E 107315 1
cover
type E
When using a Surion GPS1*BH as a manual self-protected
combination motor starter (Type E).
I
Cover enables compliance with NEC Section 430-52, 1” over air
creepage and over surface clearance, phase to phase on the
line side.
X

B.19
Surion
Enclosures for manual motor starters
Motor protection devices

Product range
A
• Surface and flush mounting plastic enclosures
(IP41 and IP55)
• Neutral and ground connection
B • Three different types of push-buttons
- Mushroom with impulse function
- Mushroom self latching, unlatching by turning
C - Mushroom self latching, unlatching with a key
• Indicator lamps
• Padlocking device for three padlocks
• Conversion kit IP41 to IP55
D

E
Technical performances
F • Used with GPS1*S manual motor starters
• Protection degree IP41 or IP55
• Possibility to mount frontal/lateral auxiliary
G contact blocks with an undervoltage release
(without or with 2NO early make auxiliary
contacts) inside the enclosures

B.20
Surion
Enclosures for only GPS 1*S
Description Cat. no. Ref. no. Pack.

Plastic Surface mounting IP41 GPES41A 101365 1


enclosures Surface mounting IP55 GPES55A 101366 1

Flush mounting IP41 GPEF41A 101367 1


Flush mounting IP55 GPEF55A 101368 1

Manual motor starter


Mounting accessories for all enclosures
Description Cat. no. Ref. no. Pack.

Neutral connection To be used inside the enclosure GPENA 101369 1

Adaptor set For enclosures used with GPS1*S and GPEUTA 107097 1
undervoltage release with 2 NO auxiliary contacts

A
Padlocking device For three padlocks with max. 8 mm shackle diameter GPEPA 101370 1
Not to be used with emergency stop handle

C
Conversion kit GPECA 101371 1
IP41 to IP55

E
Mushroom Mushroom spring return GPEPMA 101372 1
push-button Mushroom self latching, turn to release GPEPLA 101373 1
Mushroom self latching, release with a key GPEPKA 101374 1
F

G
Indicator lamps Green 110/120V GPELGAJ 101375 1
Green 220/240V GPELGAN 101376 1
Green 380/440V GPELGAU 101377 1
Green 480/500V
Green 600V
GPELGAX
GPELGAY
101378
101379
1
1
H
Red 110/120V GPELRAJ 101380 1
Red 220/240V GPELRAN 101381 1
Red 380/440V GPELRAU 101382 1
Red 480/500V
Red 600V
GPELRAX
GPELRAY
101383
101384
1
1
I
Transparent 110/120V GPELCAJ 101385 1
Transparent 220/240V GPELCAN 101386 1
Transparent 380/440V GPELCAU 101387 1
Transparent 480/500V
Transparent 600V
GPELCAX
GPELCAY
101388
101389
1
1
X

B.21
Surion
Technical data
General data
Frame size GPS1 GPS2

Rated insolation voltage Ui 690V 1000V


Rated operating voltage Ue 690V ac 690V ac
Motor protection devices

Rated impulse withstand strength Uimp 6kV 8kV


Rated frequency 50/60Hz 50/60Hz
Total power loss P (W) 0.16 to 25A 7W up to 32A 11W
32A 8.5W 40A to 50A 15W
Utilisation category: 63A 17W
IEC 947-2 (Circuit breaker) Cat. A Cat. A
IEC 947-4-1 (Motor starter) AC3 AC3

Mechanical operational performance 100,000 (70,000 for 32A) 50,000


Electrical operational performance 100,000 (70,000 for 32A) 25,000
Max.operations per hour (motor start-up) 25 25

Ambient conditions:
Storage temperature -40°C to +80°C -40°C to +80°C
Operation temperature -25°C to +60°C -25°C to +60°C
Temperature compensation -20°C to +60°C -20°C to +60°C
Ambient temperature compensation yes yes

Operational altitude up to 2000m up to 2000m


Shock resistance (IEC 68) 30g (width 20ms) 30g (width 20ms)
Vibration resistance 8g (5 to 150Hz) 8g (5 to 150Hz)

A Shock -hazard prot. (acc.DIN VDE 0106)


Protection degree (acc.to IEC529)
fingerproof
IP20
fingerproof
IP10 (IP20 with acc GPAPTP2A)

Rated current Ie up to 32A up to 63A


Overload protection IEC 947-4-1 IEC 947-4-1
B
Phase failure protection yes yes
Tripping class 10 10
Magnetic release (factory set) 13 x Iemax 13 x Iemax
C Test trip button yes yes

Standards & Approvals


IEC 947-1 / -2 / -4-1 yes yes
DIN VDE 0660T 100 / 101 / 102 yes yes
D UL508
UL508 type E
yes
Only GPS1*H
yes
yes
CE yes yes
cULus yes yes
D / S / N / Fi In process -
E Shipping approvals yes yes

F Mounting data
Terminal capacity:
Solid or stranded without end sleeve 1 x 1...10 mm2 1 or 2 x 1...25 mm2
G Stranded with end sleeve
2 x 1...6 mm2
1 or 2 x 1...6 mm2 1 x 1…25 mm2 / 2 x 1…16 mm2
AWG 1 x 18…8 / 2 x 18…10 1 x 18…2 / 2 x 18…4
Operating mechanism lockable 3.5 to 4.5 3.5 to 4.5
in OFF position diameter (mm)
H box
Terminal type screw
Tightening torque 2 Nm / 18Lb.in 5 Nm / 45 Lb.in
Screwdriver Pz2 / slotted combination Pz2 / slotted combination
Mounting:
I DIN-rail yes yes
Screws no yes
Operating position:
turning to the front 30° 30°
X turning to the back
turning to both sides
90°
180°
90°
180°

Handle operation Rocker level / Rotary Rotary

Dimensions
width (mm) 45 55
height (mm) 90 120
depth (mm) (GPS1*S) 75 / 92.5 (GPS1*H) 107.5

B.22
Surion
Ultimate short-circuit breaking capacity (Icu) in kA
For ranges GPS1BSA* / GPS1MSA*

A B C D E F G H J K L M N P R S T U
Rated current (A) 1.6 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 13 16 20 25 32 40 50 63
220/230V 100 100 100 100 100 100 100 100 100 100 100 100 50 50 50 - - -
400/415V 100 100 100 100 100 100 100 100 100 100 50 25 25 25 25 - - -
440V 100 100 100 100 100 100 100 100 50 15 10 10 10 10 10 - - -
500/525V 100 100 100 100 100 100 100 100 50 10 6 6 6 6 6 - - -
600V 100 100 100 100 100 100 3 3 3 3 3 3 3 3 3 - - -
690V 100 100 100 100 100 100 3 3 3 3 3 3 3 3 3 - - -

Manual motor starter


For ranges GPS1BHA* / GPS1MHA*

220/230V 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 - - -
400/415V 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50 - - -
440V 100 100 100 100 100 100 100 100 100 50 50 35 35 35 35 - - -
500/525V 100 100 100 100 100 100 100 100 100 50 42 10 10 10 10 - - -
600V 100 100 100 100 100 100 8 8 6 6 6 4 4 4 4 - - -
690V 100 100 100 100 100 100 8 8 6 6 6 4 4 4 4 - - -

For ranges GPS2BSA* / GPS2MSA*

220/230V - - - - - - - - - 100 100 100 50 50 50 50 50 50


400/415V - - - - - - - - - 100 50 25 25 25 25 25 25 25
440V - - - - - - - - - 15 10 10 10 10 10 10 10 10
500/525V - - - - - - - - - 10 6 6 6 6 6 5 5 5
600V - - - - - - - - - 4 4 4 4 4 4 4 4 4
690V - - - - - - - - - 4 4 4 4 4 4 4 4 4

For ranges GPS2BHA* / GPS2MHA*

220/230V - - - - - - - - - 100 100 100 100 100 100 100 100 100
A
400/415V - - - - - - - - - 100 100 50 50 50 50 50 50 50
440V - - - - - - - - - 50 50 50 50 35 35 35 35 35
500/525V - - - - - - - - - 50 42 12 12 12 10 10 10 10
600V
690V
- - - - - - - - - 6 6 5 5 5 5 5 5 5 B
- - - - - - - - - 6 6 5 5 5 5 5 5 5

Short-circuit proof with an Icu = 100kA or 50kA


C
Rated service short-circuit breaking capacity (Ics) in kA
For ranges GPS1BSA* / GPS1MSA*

A B C D E F G H J K L M N P R S T U
D
Rated current (A) 1.6 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 13 16 20 25 32 40 50 63
220/230V 100 100 100 100 100 100 100 100 100 100 100 100 38 38 38 - - -
400/415V 100 100 100 100 100 100 100 100 100 100 38 19 19 19 19 - - -
440V 100 100 100 100 100 100 100 100 38 11 8 8 8 8 8 - - - E
500/525V 100 100 100 100 100 100 100 100 38 8 5 5 5 5 5 - - -
600V 100 100 100 100 100 100 3 3 3 3 3 3 3 3 3 - - -
690V 100 100 100 100 100 100 3 3 3 3 3 3 3 3 3 - - -

For ranges GPS1BHA* / GPS1MHA* F


220/230V 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 - - -
400/415V 100 100 100 100 100 100 100 100 100 100 100 38 38 38 38 - - -
440V
500/525V
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
38
38
38
32
25
8
25
8
25
8
25
8
-
-
-
-
-
-
G
600V 100 100 100 100 100 100 6 6 5 5 5 3 3 3 3 - - -
690V 100 100 100 100 100 100 6 6 5 5 5 3 3 3 3 - - -

For ranges GPS2BSA* / GPS2MSA* H


220/230V - - - - - - - - - 100 100 100 38 38 38 38 38 38
400/415V - - - - - - - - - 100 32 19 19 19 19 19 19 19
440V
500/525V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
12
8
8
5
8
5
8
5
8
5
8
5
8
4
8
4
8
4
I
600V - - - - - - - - - 3 3 3 3 3 3 3 3 3
690V - - - - - - - - - 3 3 3 3 3 3 3 3 3

For ranges GPS2BHA* / GPS2MHA* X


220/230V - - - - - - - - - 100 100 100 100 100 100 100 100 100
400/415V - - - - - - - - - 100 100 38 38 38 38 38 38 38
440V - - - - - - - - - 38 38 38 38 25 25 25 25 25
500/525V - - - - - - - - - 38 32 9 9 9 8 8 8 8
600V - - - - - - - - - 5 5 4 4 4 4 4 4 4
690V - - - - - - - - - 5 5 4 4 4 4 4 4 4

Back-up fuses are necessary in case of possibility of a short-circuit current higher than
100kA or 50kA at the installation point of the device (on request)
Ics = 100%Icu when Icu = 100kA
Ics = 75%Icu when Icu < 100kA B.23
Surion
Back-up gl/gG fuses only if Ics > Icu (kA)
For ranges GPS1BSA* / GPS1MSA*

A B C D E F G H J K L M N P R S T U
gl/gG fuses (A) 1.6 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 13 16 20 25 32 40 50 63
230V # # # # # # # # # # # # 100 100 100 - - -
400V # # # # # # # # # # 80 100 100 100 100 - - -
440V # # # # # # # # 50 63 63 80 80 80 80 - - -
500V # # # # # # # # 50 50 63 63 63 80 80 - - -
Motor protection devices

600V # # # # # # 20 32 40 50 63 63 63 80 80 - - -
690V # # # # # # 20 32 40 50 50 63 63 63 63 - - -

GPS1*H For ranges GPS1BHA* / GPS1MHA*

230V # # # # # # # # # # # # # # # - - -
400V # # # # # # # # # # # 100 125 125 125 - - -
440V # # # # # # # # # 63 63 80 80 100 100 - - -
500V # # # # # # # # # 50 63 80 80 80 80 - - -
600V # # # # # # 25 40 50 50 63 63 63 80 80 - - -
690V # # # # # # 25 40 50 50 63 63 63 63 63 - - -

For ranges GPS2BSA* / GPS2MSA*

230V - - - - - - - - - # # # 125 125 125 125 125 160


400V - - - - - - - - - # 80 100 125 125 125 125 125 160
440V - - - - - - - - - 63 63 80 80 100 100 125 125 125
500V - - - - - - - - - 63 63 80 80 80 80 100 100 125
600V - - - - - - - - - 63 63 63 63 80 80 100 100 100
690V - - - - - - - - - 63 63 63 63 63 63 63 80 100

For ranges GPS2BHA* / GPS2MHA*


A 230V - - - - - - - - - # # # # # # # # #
400V - - - - - - - - - # # 100 125 125 125 125 125 160
440V - - - - - - - - - 63 63 80 80 100 100 125 125 125
500V - - - - - - - - - 63 63 80 80 80 80 100 100 125
B 600V - - - - - - - - - 80 63 63 63 80 80 100 100 100
690V - - - - - - - - - 80 63 63 63 63 63 63 80 100

C
Back-up gl/gG fuses only if Ics > Icu (kA)
D Manual motor starter: GPS1... Manual motor starter: GPS2..

B.24
Surion
Specific let-through energy at Ue = 400/415 V

Manual motor starter: GPS1... Manual motor starter: GPS2...

Manual motor starter


A

C
Peak current limitation at Ue = 400/415 V

Manual motor starter: GPS1... Manual motor starter: GPS2... D

B.25
Surion
Mounting possibilities of the auxiliaries
Motor protection devices

Wiring diagram Type Description

Frontal auxiliaries Auxiliary 1NO or 1NC Two frontal auxiliary contact blocks can be installed at the same time
contact block maintaining the overall width of the manual motor starter

Alarm contact block 1NO or 1NC Installed on the frontal right side. Can be mounted in combination with the
frontal auxiliary block.
The overall width of the manual motor starter is maintained

A
Lateral auxiliaries
Auxiliary contact 2NO Different catalogue numbers for left or right mounting
block 1NO + 1NC Maximum number of auxiliary contact blocks mounted on each side: 2
B 2NC Total number of auxiliary contacts in combination frontal and lateral: 8
Width of each lateral auxiliary contact block: 9 mm
GPS1 rated at 32A allows maximum 2 auxiliary contact blocks (4 contacts)

D Auxiliary/alarm
contact block
1NO (alarm) + 1NO (auxiliary)
1NO (alarm) + 1NC (auxiliary)
Installed on the left side
Maximum number of blocks per manual motor starter: 1
1NC (alarm) + 1NO (auxiliary) Can be fitted together with one lateral auxiliary contact block or one short-
1NC (alarm) + 1NC (auxiliary) circuit alarm block mounted on the left side
Width of each lateral alarm/auxiliary contact block: 9 mm
E
Short-circuit alarm 1NO + 1NC Installed on the left side
contact block Tripping in case of short-circuit only
Can be fitted together with one lateral auxiliary contact block or one auxiliary/
F alarm block mounted on the left side
Width of each short-circuit alarm contact block: 9 mm

G Shunt trip Installed on the right side


Can not be mounted together with the undervoltage release or any lateral
block mounted on the same side
Width of each shunt trip: 18 mm

H
Undervoltage trip Installed on the right side
Can not be mounted together with a shunt trip device or any lateral block
mounted on the same side
I Width of each undervoltage trip: 18 mm

X Undervoltage trip
with 2NO early
Installed on the right side
Two different types, one for the GPS1*S.. and another for the GPS1*H..and
make auxiliary GPS2.. Can not be mounted together with a shunt trip device or any lateral
contacts block mounted on the same side
Width of each undervoltage trip: 18 mm

Shunt trip, undervoltage trip and undervoltage with 2NO contacts can be mounted together with any frontal block or left
lateral block with above mentioned restrictions

B.26

32764_B22_B34_E.indd 26 11-07-2005 15:13:31


Surion
Auxiliaries
Catalogue reference GPAC*F.. GPAC*L.. GPAL.. GPAD.. GPAE..
Aux. frontal block Aux. lateral block Alarm frontal block Alarm/aux. lateral block Short-circuit alarm block

Cont. cap. contacts class (UL508) B300 / Q300 A600 / P300 B300 / Q300 A600 / P300 A600 / P300

Back-up fuses gG, gl 6A 10A 6A 10A 10A


Utilization category AC-15
Rated operating voltage Ue (Vac) 48 125 230 48 125 230 400 500 690 48 125 230 48 125 230 400 500 690 48 125 230 400 500 690
Rated operational current (A) 5 3 1.5 6 4 4 2.2 1.5 0.6 5 3 1.5 6 4 4 2.2 1.5 0.6 6 4 4 2.2 1.5 0.6

Manual motor starter


Utilization category DC-13
Rated operating voltage Ue (Vdc) 48 110 220 48 110 220 48 110 220 48 110 220 48 110 220
Rated operational current (A) 1.38 0.55 0.27 5 1.3 0.5 1.38 0.55 0.27 5 1.3 0.5 5 1.3 0.5

Mounting data
Mounting side Front Left or right Frontal right Left Left
Terminals capacity:
Solid or stranded without end sleeve 2x0.5…2.5 mm2 2x0.5…2.5 mm2 2x0.5…2.5 mm2 2x0.5…2.5 mm2 2x0.5…2.5 mm2
AWG 2x18…14 2x18…14 2x18…14 2x18…14 2x18…14
Terminal type screw screw screw screw screw
Tightening torque 0.8Nm 0.8Nm 0.8Nm 0.8Nm 0.8Nm
Screwdriver Pz2/Slotted Pz2/Slotted Pz2/Slotted Pz2/Slotted Pz2/Slotted

Dimensions width (mm) Maintain same Increase width 9 mm Maintain same Increase width 9 mm Increase width 9 mm
width width

Detailed dimensions see page B.29

A
Auxiliaries
Catalogue reference GPAC*F.. GPAC*L..
Undervoltage trip Shunt trip
Power consuption: B
Pick-up (VA/W) 21/12 21/12
Hold (VA/W) 8/1.2 -
Operating voltage
Tripping (V)
Pick-up (V)
0.35Ve-0.7Ve
0.85Ve-1.1Ve
0.7Ve-1.1Ve
-
C
Max. operation supply (ms) - 5(DC)

Rated operating voltage Ue 24V 50Hz 24V 50/60Hz


24V 60Hz
48V 50Hz
48V 60Hz
48V 50Hz / 60V 60Hz
D
48V 60Hz 110/127V 50Hz / 120V 60Hz
110/127V 50Hz / 120V 60Hz 208V 60Hz
208V 60Hz 220/230V 50Hz / 240/260V 60Hz
220/230V 50Hz / 240/260V 60Hz 240V 50Hz / 277V 60Hz E
240V 50Hz / 277V 60Hz 380/400V 50Hz
380/400V 50Hz 415/440V 50Hz / 460/480V 60Hz
415/440V 50Hz / 460/480V 60Hz 500V 50Hz / 600V 60Hz
500V 50Hz / 600V 60Hz 24 to 60Vdc
110 to 240Vdc
F
Contacts class (UL508) - -
Back-up fuses (gG,gI) 10A 10A

Mounting data G
Mounting side Right Right
Terminals capacity:
Solid or stranded without end sleeve 2x0.5…2.5 mm2 2x0.5…2.5 mm2
AWG 2x18…14 2x18…14 H
Terminal type Screw Screw
Tightening torque 0.8Nm 0.8Nm
Screwdriver Pz2/Slotted Pz2/Slotted
Dimensions
width (mm) Increase width 18 mm Increase width 18 mm
I

B.27
Surion
Dimensional drawings
Manual Motor Starter - GPS1 rocker
Motor protection devices

Manual Motor Starter - GPS1 rotary


A

F
Manual Motor Starter - GPS2
G

B.28
Surion

Auxiliary contact blocks (Frontal) Auxiliary contact blocks (Lateral)

Manual motor starter


Alarm contact blocks (Frontal) Alarm contact blocks (Lateral)
A

F
Shunt and undervoltage trip devices Short-circuit contact block
G

B.29
Surion
Dimensional drawings
GPS1 rocker + Undervoltage trip device with 2NO contacts
Motor protection devices

GPS1 rocker + Auxiliaries

C
GPS1 rotary + Auxiliaries
D

H GPS2 + Auxiliaries

B.30
Surion

External handle operator

Manual motor starter


Load side

B
Type Applicable frame

B.31
Surion
Dimensional drawings
Enclosure for GPS1 - Surface mounting
Motor protection devices

C
Enclosure for GPS1 - Surface mounting with padlocking device
D
Padlocking device
E locked

H
unlocked

B.32
Surion

Enclosure for GPS1 - Surface mounting with emergency push-button

Manual motor starter


A

B.33
Surion
Dimensional drawings

Enclosure for GPS1 - Flush mounting


Motor protection devices

C
Enclosure for GPS1 - Flush mounting with padlocking device
D
Padlocking device
E locked

H
unlocked

B.34
Contactors and overload relays
Series M - Minicontactors
C.3 Order codes
C.23 Technical data
C.29 Terminal numbering
C.50 Dimensions

Series CL - Contactors
C.11 Order codes
C.31 Technical data
C.40 Terminal numbering
C.52 Dimensions

Series CK - Contactors
C.19 Order Codes
C.42 Technical data
C.58 Dimensions

Plug-in relays and Auxiliary contactors A


Series MT0 - Thermal overload relays for minicontactors
C.61 Order codes
C.66
Motor protection devices B
Technical data
C.67 Dimensions
Contactors and Thermal overload relays C

Series RT - Thermal overload relays for contactors


Motorstarters D
C.63 Order codes
C.68 Technical data
C.72 Dimensions Control and signalling units E

Series CSC - Contactors for capacitors Electronic relays F


C.75 Order codes
C.76 Technical data
Limit switches G
C.78 Dimensions

Series 390.R - Clapper contactors Speed drive units H


C.81 Order codes
C.87 Technical data Main switches I
C.90 Dimensions

Numerical index X

C.1
Series M
Three and four pole minicontactors
6, 9 and 12A (AC3)
20A (AC1)
• Control circuit: Alternating current up to 600V
Direct current up to 440V
• Terminal numbering in accordance with EN 50012
• Fixing by clipping onto 35 mm DIN rail (EN 50022-35) or by screws
• Screws and fast-on terminals protected against accidental contact in
accordance with VDE 0106 T.100 and VBG4
• Versions: Ring terminal and printed circuit terminals
• Facility to mount instant and timed auxiliary contact blocks and voltage
suppressor block
• Degree of protection IP20 (EN 60529).
• Maximum number of auxiliary contacts to be added: 6
Contactors

Standards General data


A IEC/EN 60947-1 BS 4794
MC0... MC1... MC2...
Maximum number of poles 4 4 4
IEC/EN 60947-4-1 NFC 63-110 Rated thermal current (Ith) θ H 60º (1) (A) 20 20 20
IEC/EN 60947-5-1 CSA C22.2/14 Rated operational current Ie (2) (A) 6 9 12
B EN 50003 VDE 0660 (3x440V, 50/60Hz, AC3)
EN 50005 SEV 10254 Rated insulation current Ui (V) 750 750 750
EN 50012 JIS C8325 Rated operational current Ue (V) 690 690 690
UL 508 JEM 1038
C NEMA ICS-1 CENELEC HD 419

Standard voltages
D Approvals To complete the catalogue number, replace the symbol © by the code
corresponding to the voltage and frequency of the control circuit
(other voltages on request)
E Alternating current (V). Bifrequency coil
cULus DEMKO NEMKO
© 10 1 2 9 3 4 5 6 7 8 12 13

F AC 12 24 42 48 110 120 220 230 240 440 380 400


50/60Hz 115
SEMKO SETI IMQ Operating voltages limits with bifrequency coils:
With 60Hz =0.85 to 1.1 x Us
G With 50Hz =0.8 to 1.1 x Us in continuous service (ED=100%) with a maximum ambient temperature
of 40ºC

Alternating current (V).

H Lloyd’s Bureau RINA © A E G K M N S U W Y


Register Veritas AC 48 115 220 260 380 415 500
50Hz 127 240 400 440
AC 6 32 60 208 240 440 480 600
I 60Hz 220 277

Direct current (V)

X Order codes ! pg. C.3


© A B C D E F G H I J K L N 17 R S 16
DC 6 12 32 24 36 42 48 60 72 110 120 125 220 230 240 250 440
Auxiliary contact blocks ! pg. C.6
Accessories ! pg. C.8 Direct current (V) - Wide voltage range
Technical data ! pg. C.23
Terminal numbering ! pg. C.29 © WD WE WG WI WJ WN
Dimensions ! pg. C.51
DC 24 33 48 72 110 220

C.2
Series M
Three pole minicontactors
Max.operat.current Admissible power AC3 Aux. Control circuit: Control circuit:
Non- Motors 1-phase 3-phase contacts Alternating Direct current
inductive <440V, 115V 220V 220V 380V 500V current
loads 3~ 230V 400V •3 •1
50/60Hz Cat. no. (1) Pack Cat. no. (1) Pack
AC1 (2) AC3 (3) kW kW kW kW kW
A A HP HP HP HP HP •4 •2 Ref. no. see bottom Ref. no. see bottom

3P and 4P minicontactors
Terminal: screw
20 6 0.37 0.75 1.5 2.2 3 1 0 MC0A310AT © 20 MC0C310AT © 10
0,5 1 2 3 4 0 1 MC0A301AT © 20 MC0C301AT © 10

20 9 0.56 1.12 2.2 4 4 1 0 MC1A310AT © 20 MC1C310AT © 10


0.75 1.5 3 5.5 5.5 0 1 MC1A301AT © 20 MC1C301AT © 10

20 12 0.75 2 3 5.5 5.5 1 0 MC2A310AT © 20 MC2C310AT © 10


1 2.6 4 7.3 7.3 0 1 MC2A301AT © 20 MC2C301AT © 10

Terminal: ring terminal


20 6 0.37 0.75 1.5 2.2 3 1 0 MC0A310AR © 20 MC0C310AR © 10
0.5 1 2 3 4 0 1 MC0A301AR © 20 MC0C301AR © 10

20 9 0.56 1.12 2.2 4 4 1 0 MC1A310AR © 20 MC1C310AR © 10


0.75 1.5 3 5.5 5.5 0 1 MC1A301AR © 20 MC1C301AR © 10

20 12 0.75 2 3 5.5 5.5 1 0 MC2A310AR © 20 MC2C310AR © 10


1 2.6 4 7.3 7.3 0 1 MC2A301AR © 20 MC2C301AR © 10

A
Terminal: faston 2x2.8 insulated (5)
16 (4) 6 0.37 0.75 1.5 2.2 3 1 0 MC0A310AF © 20 MC0C310AF © 10
0.5 1 2 3 4 0 1 MC0A301AF © 20 MC0C301AF © 10

16 (4) 9 0.56 1.12 2.2 4 4 1 0 MC1A310AF © 20 MC1C310AF © 10 B


0.75 1.5 3 5.5 5.5 0 1 MC1A301AF © 20 MC1C301AF © 10

Terminal: printed circuit C


20 6 0.37 0.75 1.5 2.2 3 1 0 MC0A310AI © 20 MC0C310AI © 10
0.5 1 2 3 4 0 1 MC0A301AI © 20 MC0C301AI © 10

20 9 0.56 1.12 2.2 4 4 1 0 MC1A310AI © 20 MC1C310AI © 10


0.75 1.5 3 5.5 5.5 0 1 MC1A301AI © 20 MC1C301AI © 10 D
20 12 0.75 2 3 5.5 5.5 1 0 MC2A310AI © 20 MC2C310AI © 10
1 2.6 4 7.3 7.3 0 1 MC2A301AI © 20 MC2C301AI © 10

E
Spare coil MB0A © 10 MB0C © 10

G
(1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and
frequency of the control circuit (other voltages on request) (see C.2)
(2) Electrical endurance AC-1: MC0... 0.2 x 106 operations
MC1... 0.3 x 106 operations H
MC2... 0.35 x 106 operations
(3) Electrical endurance AC-3: MC0... (6A) = 1.2 x 106 operations
MC1... (9A) = 0.85 x 106 operations
MC2... (12A)= 0.6 x 106 operations
(4) Terminal with wire 1.5 mm2: Ie = 16A I
with wire 1 mm2: Ie = 10A
Insulated terminal type B 2.8 x 0.8 and wire 1 mm2 Ie = 8A in accordance with DIN 46247.
(5) Fast-on 1 x 6.3 terminals on request (replace letter F by H in the catalogue number)
X

For reference numbers,


see chapter X, pg. X.4

C.3
Series M
Three pole interface contactors
Max. oper. current Admissible power AC3 Aux. Voltage 24V D.C, coil 1.2W (1) Voltage 24V D.C, coil 2W (2)
Non- Motors 1-phase 3-phase contacts (1)
Cat. no. Ref. no. Pack Cat. no. (1) Ref. no. Pack
inductive <440V, 115V 220V 220V 380V 500V
load 3~ 230V 400V •3 •1
50/60Hz
(3)
AC1 AC3
A A kW kW kW kW kW •4 •2
Terminal: screw
20 6 0.37 0.75 1.5 2.2 3 1 0 MC0I310ATD 100570 10 MC0K310ATD 100574 10
0 1 MC0I301ATD 100571 10 MC0K301ATD 100575 10

20 9 0.56 1.12 2.2 4 4 1 0 MC1I310ATD 100572 10 MC1K310ATD 100576 10


0 1 MC1I301ATD 100573 10 MC1K301ATD 100577 10

20 12 0.75 2 3 5.5 5.5 1 0 MC2I310ATD 100559 10 MC2K310ATD 103590 10


0 1 MC2I301ATD 100538 10 MC2K301ATD 103591 10
Contactors

Spare coil MB0ID 100470 10 MB0KD 100471 10

A (1) No possibility of adding instantaneous auxiliary contact blocks.


(2) Facility to mount an instantaneous auxiliary contact block of two contacts or two instantaneous auxiliary contact
blocks of one contact.
(3) Electrical endurance AC-3 :
MC0... (6A) = 1.2 x 106 operations
B MC1... (9A) = 0.85 x 106 operations.
MC2... (12A) = 0.6 x 106 operations.

C.4
Series M
Four poles minicontactors
Max.oper.current Admissible power AC3 Poles Control circuit: Control circuit:
Non- Motors 1-phase 3-phase Alternating Direct current
inductive <440V, 115V 220V 220V 380V 500V current
load 3~ 230V 400V
50/60Hz Cat. no. (1) Pack Cat. no. (1) Pack
(2) (3)
AC1 AC3 kW kW kW kW kW
A A HP HP HP HP HP Ref. no. see bottom Ref. no. see bottom

3P and 4P minicontactors
Screw terminal
20 6 AC1 4 0 MC0A400AT © 20 MC0C400AT © 10
2.3 4.4 7.5 13 17 2 2 MC0AB00AT © 20 MC0CB00AT © 10
- - - - - 0 4 MC0AA00AT © 20
AC3
0.37 0.75 1.5 2.2 3
0.5 1 2 3 4
20 9 AC1 4 0 MC1A400AT © 20 MC1C400AT © 10
1.8 3.5 6.1 10.5 13.8 2 2 MC1AB00AT © 20 MC1CB00AT © 10
- - - - - 0 4 MC1AA00AT © 20
AC3
0.56 1.12 2.2 4 4
0.75 1.5 3 5.5 5.5
20 12 AC1 4 0 MC2A400AT © 20 MC2C400AT © 10
2.3 4.4 7.5 13 17 2 2 MC2AB00AT © 20 MC2CB00AT © 10
- - - - -
AC3
0.75 2 3 5.5 5.5
1 2.6 4 7.3 7.3

Terminal: faston 2x2.8 insulated (5)


20 6 AC1 4 0 MC0A400AF © 20 MC0C400AF © 10
A
2.3 4.4 7.5 13 17 2 2 MC0AB00AF © 20 MC0CB00AF © 10
- - - - - 0 4 MC0AA00AF © 20
AC3
0.37 0.75 1.5 2.2 3 B
0.5 1 2 3 4
16 (4)
9 AC1 4 0 MC1A400AF © 20 MC1C400AF © 10
1.8 3.5 6.1 10.5 13.8 2 2 MC1AB00AF © 20 MC1CB00AF © 10
- - - - - 0 4 MC1AA00AF © 20
AC3 C
0.56 1.12 2.2 4 4
0.75 1.5 3 5.5 5.5

D
Terminal: printed circuit
20 6 AC1 4 0 MC0A400AI © 20 MC0C400AI © 10
2.3
-
4.4
-
7.5
-
13
-
17
-
2
0
2
4
MC0AB00AI ©
MC0AA00AI ©
20
20
MC0CB00AI © 10 E
AC3
0.37 0.75 1.5 2.2 3
0.5 1 2 3 4
20 9 AC1
1.8 3.5 6.1 10.5 13.8
4
2
0
2
MC1A400AI ©
MC1AB00AI ©
20
20
MC1C400AI ©
MC1CB00AI ©
10
10
F
- - - - - 0 4 MC1AA00AI © 20
AC3
0.56 1.12 2.2 4 4
0.75 1.5 3 5.5 5.5 G

Spare coil MB0A © 10 MB0C © 10


H

I
(1) To complete the catalogue number, replace the symbol © by the code corresponding
to the voltage and frequency of the control circuit (see C.2)
(2) Electrical endurance AC-1: MC0... 0.2 x 106 operations
MC1... 0.3 x 106 operations
X
MC2... 0.35 x 106 operations
(3) Electrical endurance AC-3: MC0... (6A) = 1.2 x 106 operations
MC1... (9A) = 0.85 x 106 operations
MC2... (12A)= 0.6 x 106 operations
(4) Terminal with wire 1.5 mm2: Ie = 16A
with wire 1 mm2: Ie = 10A
Insulated terminal type B 2.8 x 0.8 and wire 1 mm 2 Ie = 8A in accordance
with DIN 46247.
For reference numbers,
(5) Faston 1 x 6.3 terminals on request, (replace letter F by H in the catalogue number). see chapter X, pg. X.4

C.5
Series M
Instantaneous auxiliary contact blocks
Number Combinations Contacts Contacts Aux.contacts Cat. no. Ref. no. Pack
contacts with basic in acc. with in acc.with
•3 •1
contactor EN 50012 EN 50005
10E
Front mounting •4 •2
• Two or four additional contacts, to cover combinations of 3 or 5 contacts without increasing the surface are
of the basic contactor
Screw terminal
2 21E 11 1 1 MACN211AT 100999 10
2 12E 02 0 2 MACN202AT 100998 10
2 20 2 0 MARN220AT 100994 10
2 11 1 1 MARN211AT 100993 10
2 02 0 2 MARN202AT 100992 10

4 41E 31 3 1 MACN431AT 100997 10


4 32E 22 2 2 MACN422AT 100996 10
4 23E 13 1 3 MACN413AT 100995 10
4 40 4 0 MARN440AT 100991 10
Contactors

4 31 3 1 MARN431AT 100990 10
4 22 2 2 MARN422AT 100989 10
4 13 1 3 MARN413AT 100988 10
4 04 0 4 MARN404AT 100987 10

Ring terminal
2 21E 11 1 1 MACN211AR 103557 10
2 12E 02 0 2 MACN202AR 103558 10
A 2 20 2 0 MARN220AR 103349 10
2 11 1 1 MARN211AR 103350 10
2 02 0 2 MARN202AR 103351 10

4 41E 31 3 1 MACN431AR 103559 10


B 4 32E 22 2 2 MACN422AR 103560 10
4 23E 13 1 3 MACN413AR 103561 10
4 40 4 0 MARN440AR 103352 10
4 31 3 1 MARN431AR 103353 10
4 22 2 2 MARN422AR 103354 10
C 4 13 1 3 MARN413AR 103355 10
4 04 0 4 MARN404AR 103300 10

D
Terminal: faston 2x2.8 insulated (1)
4 41E 31 3 1 MACF431AF 100555 10
E 4 32E 22 2 2 MACF422AF 100556 10
4 23E 13 1 3 MACF413AF 100557 10
4 40 4 0 MARF440AF 100503 10
4 31 3 1 MARF431AF 100504 10
4 22 2 2 MARF422AF 100505 10
F 4 13 1 3 MARF413AF 100506 10
4 04 0 4 MARF404AF 100507 10

G
(1) Terminal with wire 1 mm2: Ie = 10A
Insulated terminal type B 2.8 x 0.8 with wire 1 mm2: Ie = 8A, in accordance with DIN 46247
H

C.6
Series M
Instantaneous auxiliary contact blocks
Number Combinations Contacts Contacts Aux.contacts Cat. no. Ref. no. Pack
contacts with basic in acc. with in acc.with
contactor EN 50012 EN 50005 •3 •1

10E
Lateral mounting •4 •2
• One or two additional blocks, to cover combinations of 1 or 2 contacts without increasing the height of
the basic unit contactor

3P and 4P minicontactors
Screw terminal
1 20 10 1 0 MACL110AT 100560 10
1 11E 01 0 1 MACL101AT 100561 10

Ring terminal
1 20 10 1 0 MACL110AR 103555 10
1 11E 01 0 1 MACL101AR 103556 10

Terminal: faston 2x2.8 insulated (1)


1 20 10 1 0 MACL110AF 100562 10
1 11E 01 0 1 MACL101AF 100563 10

Terminal: printed circuit


1 20 10 1 0 MACL110AI 100564 10
1 11E 01 0 1 MACL101AI 100565 10

• One or two additional blocks, when up to 6 or 7 contacts are needed (combination possible
A
with frontal blocks)
• One or two additional blocks on both sides, to cover up to five contacts (combination possible only
with lateral blocks)
Screw terminal B
1 10 1 0 MARL110ATS 100519 10
1 01 0 1 MARL101ATS 100520 10

Ring terminal C
1 10 1 0 MARL110ARS 103299 10
1 01 0 1 MARL101ARS 103298 10

D
Terminal: faston 2x2.8 insulated (1)
1
1
10
01
1
0
0
1
MARL110AFS
MARL101AFS
100521
100522
10
10
E

Terminal: printed circuit


1 10 1 0 MARL110AIS 100523 10
F
1 01 0 1 MARL101AIS 100524 10

G
(1) Terminal with wire 1 mm2: Ie = 10A
Insulated terminal type B 2.8 x 0.8 with wire 1 mm2: Ie = 8A, in accordance with DIN 46247

C.7
Series M
Accessories
For use Time Function Ue Cat. no. Ref. no. Pack
with:

Electronic timer Lateral or front fixing to the contactor


block MCR..MC_ ... 0.5 - 60 seg. delay ON 24... 250V AC/DC MREBC10AC2 100541 10
MCR..MC_ ... 0.2 - 24 seg. delay ON 24...250V AC/DC MREBC20AC2 100542 10

DIN rail adaptor For fixing onto EN 50022-35


for electronic MREBC... MVB0R 100543 10
timer block
Contactors

For use Type Control Ue Cat. no. Ref. no. Pack


with:

Voltage suppressor Connection and (plug-in) fixing


block on to the connector
MCRA,MC_ ... R/C AC 12...60V 50/60Hz MP0AAE1 100544 10
MCRA,MC_ ... R/C AC 72...250V 50/60Hz MP0AAE2 100545 10
MCRC,MC_ ... Diode DC 6...250V DC MP0CAE3 100546 10
MCRC,MC_ ... Varistor AC/DC 24-48V MP0DAE4 100536 10

B For use
with:
Phases Terminal
capacity
Ue Cat. no. Ref. no. Pack

Pole paralleling To connect two, three or four phases in parallel


links MC_ ... 2, 3, 4 (parallel) Ø4.5mm - 16mm2 MVP0C 100600 10
C

Cat. no. Ref. no. Pack


E For use
with:

Mechanical Mechanical interlock and pole jumpers


interlock MCR, MC_ ... MMH0 100547 10
F

For use Cat. no. Ref. no. Pack


H with:

Identification MCR, MC_ ... Labels (10 sheets of 260 labels) EAT 260 100548 1
MCR, MC_ ... Labelling plate base. Plug-in labelling plate bases SPR 100549 1
(50 pieces in one pack)
I

C.8
Series M
Multipack. Series M and Series CL
To reduce the amount of waste packaging material and to save time during installation,
we offer the opportunity to order contactors in a multipack without the individual packaging.
Product Type Standard pack Multipack (1)
Minicontactors MC0A...MC2A 20 40
Contactors CL00A...CL25A... 20 40
CL03...CL45... 10 20

3P and 4P minicontactors
(1) The quantity ordered must be a multiple of the quantity in each multipack
( with the same frame/size and coil voltage)

How to order
To order a multipack, add the suffix MP to the standard catalogue number
Example Standard pack Multipack
MC0A310ATN MC0A310ATN MP
(40 pieces)
CL03A400MJ CL03A400MJ MP
(20 pieces)

C.9
Series CL
Three and four pole contactors
9 to 105A (AC3)
25 to 140A (AC1)
• Control circuit: Alternating current up to 690V
Direct current up to 440V
• Terminal numbering in accordance with EN 50005 and EN 50012
• Fixing by clipping onto 35mm DIN rail EN 50022-35 or by screws
• Screws protected against accidental contact in accordance with VDE 0106
T.100, VBG4.
• Ring terminal version
• Three coil terminals
• Mounting possibilities of front/side instantaneous auxiliary contact blocks,
timed auxiliary contact blocks, mechanical latch, transient suppressor block
and interface modules.
Contactors

• Degree of protection: IP20 to CL00 ... CL02


IP10 to CL25 ... CL10
• Maximum number of auxiliary contacts: 4 for CL00 ... CL25
6 for CL04 ... CL45
8 for CL06 ... CL10

A Standards Standard voltages


IEC/EN 60947-1 CSA 22.2/14 To complete the catalogue number, replace the symbol © by the code
IEC/EN 60947-4-1 NFC 63-110 corresponding to the voltage and frequency of the control circuit.
B IEC/EN 60947-5-1 ASE 1025
Alternating current (V). Dual-frequency coil
EN 50005 UNE 20109
© 1 2 9 3 4 5 6 7 13 8 15
UL 508 VDE 0660/102
NEMA ICS 1 CENELEC HD 419 AC 24 42 48 110 120 220 230 240 400 440 480
C BS 5424 & 775 50/60Hz 115

Alternating current (V).


© E K L N T U W Y Z
D Approvals AC 32 127 220 380 415 500 660
50Hz 230 400 690
AC 208 277 380 480 460 600
E 60Hz
cULus SETI IMQ
(hasta Ith=32A)
Direct current (V)
F For contactors type CL...D / Operating limits: 0.80 ... 1.10 x Us
© B D E F G H I J K N P R T X
Voltage 12 24 36 42 48 60 72 110 120 220 230 240 250 440
G 125
Lloyd’s Bureau RINA
Coil with electronic module for contactors CL...E (can also be used with alternating current)
Register Veritas
© D F H J N Y
H Voltage 24 42 60 110 220 440
28 48 72 125 250

Direct current (V). Coil with wide voltage range (0.70 ... 1.30 x Us)
I For contactors type CL...D
© WB WD WE WF WG WH WI WJ WK WN WP WR WT WX Maximun number of add-on
auxiliary contact blocks:
DC 12 24 33 42 48 60 72 110 125 220 230 240 250 440
X Coil with electronic module for contactors CL...E
CL00D...CL02D :
CL03D...CL45D :
2NO or 1NC
1NO and 1NC
Order codes ! pg. C.11 CL05D...CL10D : 4NO or 2NC
Auxiliary contact blocks ! pg. C.15 © WD WE WF WH WJ WN CL05E...CL10E : 4 cont. aux.
Accessories ! pg. C.16 Voltage 24 33 48 72 110 220 Different auxiliary contact
Technical data ! pg. C.31 configurations, contact us.
Terminal numbering ! pg. C.39
Dimensions ! pg. C.52

C.10
Series CL
Three pole contactors. Screw terminal
Max.oper.current Admissible power Electrical Aux. Control circuit: Control circuit: Control circuit:
Non- Motors AC3 endurance contacts Alternating Direct current Coil with electronic
inductive <440V, 220V 380V 415V 500V current module (AC/DC)
load 3~ 230V 400V 440V
50/60Hz Cat. •3 •1 Cat. no. (1) Pack Cat. no. (1) Pack Cat. no. (1) Pack
AC1 AC3 kW kW kW kW AC3 (4) (4) (4)

A A HP HP HP HP Operations • 4 •2 Ref. no. see bottom Ref. no. see bottom Ref. no. see bottom
25 9 2.2 4 4 5.5 2x106 0 0 CL00A300T© 5
3 5.5 5.5 7.5 1 0 CL00A310T© 5 CL00D310T© 10
0 1 CL00A301T© 5 CL00D301T© 10

3P and 4P contactors
25 12 3 5.5 5.5 7.5 2x106 0 0 CL01A300T© 5
4 7.5 7.5 10 1 0 CL01A310T© 5 CL01D310T© 10
0 1 CL01A301T© 5 CL01D301T© 10

32 18 4 7.5 7.5 10 1.7x106 0 0 CL02A300T© 5


5.5 10 10 13.5 1 0 CL02A310T© 5 CL02D310T© 10
0 1 CL02A301T© 5 CL02D301T© 10

45 25 7.5 11 11 15 1.2x106 0 0 CL25A300T© 5 CL25D300T© 10


(2)
10 15 15 20 1 0 CL25A310T© 5
(2)
0 1 CL25A301T© 5

45 25 7.5 12 12 15 2x106 0 0 CL03A300M© 10


10 16 16 20 1 0 CL03A310M© 10 CL03D310M© 10
0 1 CL03A301M© 10 CL03D301M© 10

60 32 9 16 16 18.5 2x106 0 0 CL04A300M© 10


12 22 22 25 1 0 CL04A310M© 10 CL04D310M© 10
0 1 CL04A301M© 10 CL04D301M© 10

60 40 11 18.5 22 25 2x106 0 0 CL45A300M©


(3)
10 CL45D300M© 10 A
15 25 30 34 1 1 CL45A311M© 10

90 50 15 22 25 30 1.8x106 0 0 CL06A300M© 1 CL06D300M© 1 CL06E300M© 1


20 30 34 40 1 1 CL06A311M© (3) 1 B
110 65 18.5 30 37 40 1.7x106 0 0 CL07A300M© 1 CL07D300M© 1 CL07E300M© 1
(3)
25 40 50 55 1 1 CL07A311M© 1
C
110 80 22 37 45 45 1.5x10 6
0 0 CL08A300M© 1 CL08D300M© 1 CL08E300M© 1
CL08A311M© (3) 1
30 50 60 60 1 1
D
140 95 25 45 50 55 1.7x106 0 0 CL09A300M© 1 CL09D300M© 1 CL09E300M© 1
(3)
34 60 68 75 1 1 CL09A311M© 1

140 105 30 55 55 65 1.5x106 0 0 CL10A300M© 1 CL10D300M© 1 CL10E300M© 1 E


(3)
40 75 75 88 1 1 CL10A311M© 1

F
Spare CL00 - CL25 LB1A © 5 LB1D © 5
coils CL03 - CL45 LB3A © 5 LB3D © 5
CL06 - CL10 LB4A © 5 LB4D © 1
coil + electronic module CL06E - CL10E LB4E © 1 G

H
(1) To complete the catalogue number, replace the symbol © by the code corresponding
to the voltage and frequency of the control circuit (see C.10).
(2) Equipped with one block BCLF
(3) Equipped with two blocks BCLF
I
(4) Multipack, see C.9

For reference numbers,


see chapter X, pg. X.4

C.11
Series CL
Three pole contactors. Ring terminal
Max.oper.current Admissible power Electrical Aux. Control circuit: Control circuit:
Non- Motors AC3 endurance contacts Alternating Direct current
inductive <440V, 220V 380V 415V 500V current
load 3~ 230V 400V 440V
50/60Hz Cat. •3 •1 Cat. no. (1) Pack Cat. no. (1) Pack
(4) (4)
AC1 AC3 kW kW kW kW AC3
A A HP HP HP HP Operations • 4 •2 Ref. no. see bottom Ref. no. see bottom
25 9 2.2 4 4 5.5 2x106 0 0 CL00A300R© 5
3 5.5 5.5 7.5 1 0 CL00A310R© 5 CL00D310R© 10
0 1 CL00A301R© 5 CL00D301R© 10

25 12 3 5.5 5.5 7.5 2x106 0 0 CL01A300R© 5


4 7.5 7.5 10 1 0 CL01A310R© 5 CL01D310R© 10
0 1 CL01A301R© 5 CL01D301R© 10

32 18 4 7.5 7.5 10 1.7x106 0 0 CL02A300R© 5


5.5 10 10 13.5 1 0 CL02A310R© 5 CL02D310R© 10
0 1 CL02A301R© 5 CL02D301R© 10
Contactors

(2)
45 25 7.5 11 11 15 1.2x106 0 0 CL25A300R© 5 CL25D300R© 10
(2)
10 15 15 20 1 0 CL25A310R© 5
0 1 CL25A301R© 5

45 25 7.5 12 12 15 2x106 0 0 CL03A300R© 10


10 16 16 20 1 0 CL03A310R© 10 CL03D310R© 10
0 1 CL03A301R© 10 CL03D301R© 10

60 32 9 16 16 18.5 2x106 0 0 CL04A300R© 10


12 22 22 25 1 0 CL04A310R© 10 CL04D310R© 10
0 1 CL04A301R© 10 CL04D301R© 10

A 60 40 11 18.5 22 25 2x106 0 0 CL45A300R© (3) 10 CL45D300R© 10


15 25 30 34 1 1 CL45A311R© 10

90 50 15 22 25 30 1.8x106 0 0 CL06A300R© (3) 1 CL06D300R© 1


B 20 30 34 40 1 1 CL06A311R© 1

110 65 18.5 30 37 40 1.7x106 0 0 CL07A300R© (3) 1 CL07D300R© 1


25 40 50 55 1 1
C CL07A311R© 1

110 80 22 37 45 45 1.5x106 0 0 CL08A300R© (3) 1 CL08D300R© 1


30 50 60 60 1 1 CL08A311R© 1
D
140 95 25 45 50 55 1.7x106 0 0 CL09A300R© (3) 1 CL09D300R© 1
34 60 68 75 1 1 CL09A311R© 1

E 140 105 30 55 55 65 1.5x106 0 0 CL10A300R© (3) 1 CL10D300R© 1


40 75 75 88 1 1 CL10A311R© 1

F
Spare coils CL00 - CL25 LB1A © 5 LB1D © 5
CL03 - CL45 LB3A © 5 LB3D © 5
CL06 - CL10 LB4A © 5 LB4D © 1
G

H
(1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and
frequency of the control circuit (see C.10).
I (2) Equipped with one block BCRF
(3) Equipped with two blocks BCRF
(4) Multipack, see C.9

For reference numbers,


see chapter X, pg. X.4

C.12
Series CL
Four pole contactors. Screw terminal
Max.oper.current Admissible power Electrical Power Control circuit: Control circuit: Control circuit:
Non- AC1 endurance contacts Alternating Direct current Coil with electronic
inductive 220V 380V 415V 500V current module (AC/DC)
loads 230V 400V 440V
Cat. Cat. no. (1) Pack Cat. no. (1) Pack Cat. no. (1) Pack
AC1 (2) (2) (2)
AC1 AC3 kW kW kW kW
A A Operations Ref. no. see bottom Ref. no. see bottom Ref. no. see bottom
25 12 9.5 16.5 18 21.5 1.5x106 4 0 CL01A400T© 5 CL01D400T© 10

32 18 12 22 23 27.5 1.5x106 4 0 CL02A400T© 5 CL02D400T© 10

3P and 4P contactors
45 25 17 29 32 39 2x106 4 0 CL03A400M© 10 CL03D400M© 10

60 32 22.5 39.5 43 52 1.5x106 4 0 CL04A400M© 10 CL04D400M© 10


CL05E400M© 1
90 50 34 59 64 78 1.5x106 4 0 CL05A400M© 1 CL05D400M© 1
CL07E400M© 1
110 65 42 72.5 79 95 1.8x106 4 0 CL07A400M© 1 CL07D400M© 1
CL09E400M© 1
140 95 53 92 100 121 1.8x106 4 0 CL09A400M© 1 CL09D400M© 1

Max.oper.current Admissible power Power Control circuit: Control circuit: Control circuit:
Non- Motors AC3 contacts Alternating Direct current Coil with electronic
inductive <440V, 220V 380V 415V 500V current module (AC/DC)
loads 3~ 230V 400V 440V
Cat. no. (1) Pack Cat. no. (1) Pack Cat. no. (1) Pack
A
50/60Hz
(2) (2) (2)
AC3 kW kW kW kW
AC1 A HP HP HP HP
Ref. no. see bottom Ref. no. see bottom Ref. no. see bottom
25 12 3
4
5.5
7.5
5.5
7.5
7.5
10
2 2 CL01AB00T© 5 CL01DB00T© 5 B
32 18 4 7.5 7.5 10 2 2 CL02AB00T© 5 CL02DB00T© 5
5.5 10 10 13.5

45 25 7.5 12 12 15 2 2 CL03AB00M© 10 CL03DB00M© 10


C
10 16 16 20

60 32 9 16 16 18.5 2 2 CL04AB00M© 10 CL04DB00M© 10


12 22 22 25 D
90 40 11 18.5 22 25 2 2 CL05AB00M© 1 CL05DB00M© 1 CL05EB00M© 1
15 25 30 34

110 65 18.5
25
30
40
37
50
40
55
2 2 CL07AB00M© 1 CL07DB00M© 1 CL07EB00M© 1 E
110 80 22 37 45 45 2 2 CL08AB00M© 1 CL08DB00M© 1 CL08EB00M© 1
30 50 60 60
F

Spare coils CL00 - CL25


CL03 - CL45
LB1A
LB3A
©
©
5
5
LB1D ©
LB3D ©
5
5
G
CL05A - CL08A LB4A © 5 LB4D © 1
Coil + Electronic module CL05E - CL08E LB4E © 1 LB4E © 1

I
(1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and frequency of
the control circuit (see C.10).
(2) Multipack, see C.9
X

For reference numbers,


see chapter X, pg. X.4

C.13
Series CL
Four poles. Ring terminal
Max.oper.current Admissible power Electrical Power Control circuit: Control circuit:
Non- AC1 endurance contacts Alternating Direct current
inductive 220V 380V 415V 500V current
load 230V 400V 440V
Cat. Cat. no. (1) Pack Cat. no. (1) Pack
AC1 AC3 kW kW kW kW AC1 (2) (2)

A A Operations
Ref. no. see bottom Ref. no. see bottom
25 12 9.5 16.5 18 21.5 1.5x106 4 0 CL01A400R© 5 CL01D400R© 10

32 18 12 22 23 27.5 1.5x106 4 0 CL02A400R© 5 CL02D400R© 10

45 25 17 29 32 39 2x106 4 0 CL03A400R© 10 CL03D400R© 10

60 32 22.5 39.5 43 52 1.5x106 4 0 CL04A400R© 10 CL04D400R© 10

90 50 34 59 64 78 1.5x106 4 0 CL05A400R© 1 CL05D400R© 1

110 65 42 72.5 79 95 1.8x106 4 0 CL07A400R© 1 CL07D400R© 1


Contactors

140 95 53 92 100 121 1.8x106 4 0 CL09A400R© 1 CL09D400R© 1

Max.oper.current Admissible power Power Control circuit: Control circuit:


Non- Motors AC3 contacts Alternating Direct current
inductive <440V, 220V 380V 415V 500V current

A load 3~
50/60Hz
230V 400V 440V
Cat. no. (1) Pack Cat. no. (1) Pack
(2) (2)
AC1 AC3 kW kW kW kW
A A HP HP HP HP Ref. no. see bottom Ref. no. see bottom
25 12 3 5.5 5.5 7.5 2 2 CL01AB00R© 5 CL01DB00R© 5
B 4 7,5 7,5 10

32 18 4 7.5 7.5 10 2 2 CL02AB00R© 5 CL02DB00R© 5


5.5 10 10 13.5

C 45 25 7.5 12 12 15 2 2 CL03AB00R© 10 CL03DB00R© 10


10 16 16 20

60 32 9 16 16 18.5 2 2 CL04AB00R© 10 CL04DB00R© 10


12 22 22 25
D

E Spare coils CL00 - CL25 LR1A © 5 LR1D © 5


CL03 - CL45 LR3A © 5 LR3D © 5
CL05A - CL08A LR4A © 5 LR4D © 1

G
(1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and
frequency of the control circuit (see C.10).
(2) Multipack, see C.9
H

For reference numbers,


see chapter X, pg. X.4

C.14
Series CL
Auxiliary contact blocks
Instantaneous Number Contacts Type Time Cat. no. Ref. no. Pack
of contacts •5
•3 •1 •7

•4 •2 •8 •6

Frontal Terminal: screw


mounting 1 1 0 0 0 BCLF10 104700 10
1 0 1 0 0 BCLF01 104701 10
1 0 0 1 0 BCLF10G 104702 10
1 0 0 0 1 BCLF01G 104703 10

3P and 4P contactors
Terminal: ring terminal
1 1 0 0 0 BCRF10 108901 10
1 0 1 0 0 BCRF01 108902 10

Side Terminal: screw


mounting 2 2 0 0 0 BCLL20 104706 10
2 1 1 0 0 BCLL11 104707 10

For combinations of more than 4 front-mounted and 2 side-mounted auxiliary contact blocks
2 2 0 0 0 BRLL20 104704 10
2 1 1 0 0 BRLL11 104705 10
2 0 2 0 0 BRLL02 106622 10

Pneumatic timer A
Front Terminal: screw
mounting 2 0 0 1 1 Delay ON 0.1 - 30 sec. BTLF30C 104709 10
2
2
0
0
0
0
1
1
1
1
Delay ON
Delay OFF
1 - 60 sec.
0.1 - 30 sec.
BTLF60C
BTLF30D
104710
104711
10
10
B
2 0 0 1 1 Delay OFF 1 - 60 sec. BTLF60D 104712 10

Terminal: ring terminal


2
2
0
0
0
0
1
1
1
1
Delay ON
Delay ON
0.1 - 30 sec.
1 - 60 sec.
BTRF30C
BTRF60C
108903
108904
10
10
C
2 0 0 1 1 Delay OFF 0.1 - 30 sec. BTRF30D 108905 10
2 0 0 1 1 Delay OFF 1 - 60 sec. BTRF60D 108906 10

Seaking cover protection for pneumatic timer BTLFX 113001 5 D

E
Accessories
Number Contacts For use Cat. no. (1) Ref. no. Pack
of contacts
•3 •1 •7 •5
with:
F
•4 •2 •8 •6

Interlock Mechanical
G
- - - - - CL00 ... CL10 BELA 104723 5
Mech./ electrical
2 0 2 - - CL00 ... CL10 BELA02 104724 5
H
Support interlock
Only for direct current contactors CL00D...CL10D SBELA 101017 5

I
Mechanical Frontal mounted to the contactor
latch blocks CL00 ... CL10 RMLF © see bottom 20
X
© D G HC J N U Y
50Hz 24, 32 42, 48 110, 115, 120, 127 220, 230, 240 380, 400, 415, 440, 480 500, 660/690
60HZ 24, 32 48, 60 110, 115, 120, 127 208, 220, 240, 277 380, 400, 415, 440, 480 600
DC 24, 32, 36 42, 48 60, 72 110, 120, 125 220, 230, 240, 250 440

1) To complete the catalogue number, replace the symbol © by the For reference numbers,
code corresponding to the voltage and frequency of the control
see chapter X, pg. X.4
circuit (see C.10).
C.15
Series CL
Accessories
For use Type Control circuit Ue Cat. no. Ref. no. Pack
with:

Transient voltage Fixation to the coil terminals, that allows simultaneous use with the auxiliary contact blocks.
suppressor block CL00 ... CL45 R/C AC 12V ... 48V BSLR2G 104713 10
CL00 ... CL45 R/C AC 50V ... 127V BSLR2K 104714 10
CL00 ... CL45 R/C AC 130V ... 250V BSLR2R 104715 10

CL05A ... CL10A R/C AC 12V ... 48V BSLR3G 104716 10


CL05A ... CL10A R/C AC 50V ... 127V BSLR3K 104717 10
CL05A ... CL10A R/C AC 130V ... 250V BSLR3R 104718 10

CL_ _ D Diode DC 12V ... 600V BSLDZ 104719 10

CL00 ... CL10 Varistor AC / DC 24V ... 48V BSLV3G 104720 10


CL00 ... CL10 Varistor AC / DC 50V ... 127V BSLV3K 104721 10
CL00 ... CL10 Varistor AC / DC 130V ... 250V BSLV3R 104722 10
CL00 ... CL10 Varistor AC / DC 277V ... 500V BSLV3U 110836 10
Contactors

For use Control circ. Type Time Cat. no. Ref. no. Pack
with:

Electronic timer Fixation to the coil terminals, that allows simultaneous use with the auxiliary contact blocks.
module CL00 ... CL10 24-250V AC/DC delay ON 0.1 - 2 sec. BETL02C 113602 5
CL00 ... CL10 24-250V AC/DC delay ON 1.5 - 45 sec. BETL45C 113603 5

CL00 ... CL10 24-250V AC/DC delay OFF 0.1 - 2 sec. BETL02D 113604 5
A CL00 ... CL10 24-250V AC/DC delay OFF 1.5 - 45 sec. BETL45D 113605 5

B
For use Control circ. Type Ue Cat. no. Ref. no. Pack
with:
C Interface module Fixation to the coil terminals, that allows simultaneous use with the auxiliary contact blocks.
CL00 ... CL10 24-250V AC Relay 24V IMRD 113606 5
CL00 ... CL45 24-250V DC Relay 48V IMRG 113607 5

D Relay + forced operation


Relay + forced operation
24V
48V
IMRFD
IMRFG
113608
113609
5
5

Solid state 24V IMSSD 113610 5

E Auto/Manual/Off control 24-250V IMAMS 113611 5

Transient voltage CL00 ... CL45 24-240V AC R/C 24-48V IMRC2G 113601 10
suppressor block to CL00 ... CL45 24-240V AC R/C 50-127V IMRC2K 113600 10
F use with interface CL00 ... CL45 24-240V AC R/C 130-240V IMRC2R 113599 10
modules
CL05A ...CL10A 24-240V AC R/C 24-48V IMRC3G 113598 10
CL05A ...CL10A 24-240V AC R/C 50-127V IMRC3K 113597 10
CL05A ...CL10A 24-240V AC R/C 130-240V IMRC3R 113596 10
G CL _ _ D 24-240V AC Diode 12-600V IMD1Z 113595 10

CL00 ... CL10 24-240V AC Varistor 24-48V IMV3G 113594 10


CL00 ... CL10 24-240V AC Varistor 50-127V IMV3K 113593 10
H CL00 ... CL10 24-240V AC Varistor 130-240V IMV3R 113592 10

C.16
Series CL
Accessories
For use Cat. no. Ref. no. Pack
with:

Identification CL00 ... CL10 Sheets of labels (sheets of 260 labels each) EAT 260 100548 1
CL00 ... CL10 Labelling plate base (50 pieces in one pack) SPR 100549 1

Pole terminal CL03 ... CL04 PTP04 113850 8

3P and 4P contactors
protector IPXXB CL45 PTP45 113851 6
CL05 ... CL08 PTP08 113852 8
CL09 ... CL10 PTP10 113853 8

Spares
For use Number of sets Type Cat. no. Ref. no. Pack
with:

Contact kits
CL00_ _ _ 3 NO V31200B 104738 1

CL01_3_/CL01_4_ 3 NO V31201B 104739 1


CL01_B_ 4 2NO-2NC VB1201B 104740 1

CL02_3_/CL02_4_ 3 NO V31202B 104741 1


CL02_B_ 4 2NO-2NC VB1202B 104742 1

CL25_3_ 3 NO V31225B 104757 1


A
CL03_3_/CL03_4_ 3 NO V31203B 104743 1
CL03_B_ 4 2NAO-2NC VB1203B 133170 1

CL04_3_/CL04_4_ 3 NO V31204B 104745 1


B
CL04_B_ 4 2NO-2NC VB1204B 133885 1

CL45_3_ 3 NO V31245B 104758 1

CL05_4_ 4 NO V31205B 104747 1


C
CL05_B_ 4 2NO-2NC VB1205B 104748 1

CL06_ _ _ 3 NO V31206B 104749 1

CL07_3_/CL07_4_ 3 NO V31207B 104750 1


D
CL07_B_ 4 2NO-2NC VB1207B 104751 1

CL08_3_/CL08_4_ 3 NO V31208B 104752 1


CL08_B_ 4 2NO-2NC VB1208B 104753 1 E
CL09_ _ _ 3 NO V31209B 104754 1

CL10_ _ _ 3 NO V31210B 104755 1


F

C.17
Series CK
Three and four pole contactors
150 to 825A (AC3)
200 to 1250A (AC1)
• Control circuit: Alternating current up to 690V
Direct current up to 500V
• Degree of protection IP00 (IPxxB with accessories)
• CK07...CK13: auxiliary and coil terminals originally protected against
accidental contacts.
Protection for power contacts on request (see accessories)
• Terminals protected against accidental contacts according to VDE 0106
T.100, VBG4.
• CK_ _E_with electronic module suitable for DC and AC. (50/60Hz)
• CK contactors always provided with one auxiliary contact block BCLL11
(1NO+1NC)
Contactors

A Standards Standard voltages


IEC/EN 60947-1 CSA 22.2/14 To complete the catalogue number, replace the symbol © by the code
IEC/EN 60947-4-1 CENELEC HD 419 corresponding to the voltage and frequency of the control circuit.
B IEC/EN 60947-5-1 NFC 63-110
Alternating current (V)
EN 50005 ASE 1025
Three-pole contactors: CK75CA3..., CK08CA3..., CK85BA3...
UL 508 UNE 20109
Four-pole contactors: CK07BA4..., CK08BA4...
NEMA ICS 1 VDE 0660/102
C BS 5424 & 775
© C D F G H I J K M N R S T U V W X Y Z
50Hz 24 42 48 110 127 220 240 380 415 440 500 660
230 400 690

D Approvals 60Hz 24 48 110 120 220 277 240 380 480 440 600

Alternating current (V). Dual-frequency coil

E Three-pole contactors:
Four-pole contactors:
CK75CA3..., CK08CA3..., CK85BA3...
CK07BA4..., CK08BA4...
cULus © 1 2 3 6 13
50/60Hz 24 48 110 230 400
F
Alternating current (V) Control circuit with
Three-pole contactors: CK13BA3... rectifier bridge
G Lloyd’s Bureau RINA
Four-pole contactors: CK13BA4... © J N U
© J N U Y Z 50Hz 110 220 380
Register Veritas
50/60Hz 110 220 380 480 600 230 400

H 240 440 500 660 60Hz 120 240 480

Direct current (V). With electronic module (0.7 ... 1.3 x Us)
Three-pole contactors: CK75CE3...., CK08CE3.....
I
© WD WE WF WH WJ WN
Voltage 24 33 48 72 110 220

X Alternating c. / Direct c. (V). With electronic module (0.8 ... 1.10 x Us)
Three-pole & four-pole contactors: CK ....... E......

Order codes ! pg. C.19 © D F J N U Y


Aux. contact blocks ! pg. C.20 Voltage 24 42 110 220 380 440
Accessories & Spares ! pg. C.21 28 48 127 250 415 500
Technical data ! pg. C.42
Dimensions ! pg. C.58

C.18
Series CK
Three pole contactors
Max.oper.current Admissible power AC3 Electrical Control circuit: Control circuit:
endurance Alternating A.C. / D.C.
Non- Motors
current
inductive <440V, 220V 380V 415V 440V 500V
loads 3~ 230V 400V 440V
50/60Hz Cat. Cat. no. (1) Pack Cat. no. (1) Pack
AC1 AC3 kW kW kW kW kW AC3
A A HP HP HP HP HP Operations Ref. no. see bottom Ref. no. see bottom
250 150 45 75 80 80 100 1.7x106 CK75CA311 © 1 CK75CE311 © 1
60 100 108 108 135

1.2x106 CK08CA311 © 1 CK08CE311 © 1

3P and 4P contactors
250 185 55 90 100 100 110
75 125 135 135 150

315 205 65 110 125 125 132 1.7x106 CK85BA311 © 1 CK85BE311 © 1


88 150 170 170 180

315 250 75 132 132 132 160 1.5x106 CK09BE311 © 1


100 180 180 180 220

450 309 90 160 160 185 200 1,1x106 CK95BE311 © 1


125 220 220 250 270

600 420 125 220 230 230 300 1x106 CK10CE311 © 1


170 300 312 312 405

700 550 160 280 315 315 400 0.8x106 CK11CE311 © 1


220 380 425 425 540

1000 700 220 375 400 425 480 0.7x106 CK12BE311 © 1


300 510 540 650

1250 825 250 450 450 450 500


340 610 610 610 680
0.7x106 CK13BA311 © 1 A

B
Spare coil CK75CA3 ... CK08CA3 C12168 © 1
CK85BA3 C04255 © 1
CK13BA3 C08998 © 1
Control circuit with incorporated rectifier bridge CK13BA3 C09120 © 1
C
Coil CK75CE3 ... CK08CE3 KB4E © 1
CK85BE3 ... CK95BE3 KB5E © 1
CK12BE3 KB6E © 1

Electronic module
CK10CE3 ... CK11CE3
CK75CE3 ... CK08CE3
KB7E ©
KM4E ©
1
1 D
CK85BE3 ... CK95BE3 KM5E © 1
CK12BE3 KM6E © 1
CK10CE3 ... CK11CE3 KM7E © 1
E
(1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and
frequency of the control circuit (see C.18).

For reference numbers,


see chapter X, pg. X.4

C.19
Series CK
Four pole contactors
Max.oper. Admissible power Control circuit: Control circuit:
Electrical
current Alternating A.C. / D.C.
AC3 AC1 endurance
current
Non- 380V 220V 380V 415V 440V 500V
inductive 400V 230V 400V
loads Cat. Cat. no. (1) Pack Cat. no. (1) Pack
AC1 AC3
A kW A kW kW kW kW kW Operations Ref. no. see bottom Ref. no. see bottom
200 55 105 76 131 143 151 173 1x106 CK07BA41 © 1 CK07BE411 © 1

325 100 185 123 214 233 247 281 0.6x106 CK08BA411 © 1 CK08BE411 © 1

400 132 250 152 263 287 304 346 0.6x106 CK09BE411 © 1

500 160 309 191 329 359 380 415 0.6x106 CK95BE411 © 1
Contactors

600 220 408 228 395 431 456 519 0.5x106 CK10CE411 © 1

700 280 530 266 460 503 533 606 0.4x106 CK11CE411 © 1

1000 375 680 381 658 719 762 866 0.4x106 CK12BE411 © 1

1250 450 800 476 822 898 952 1082 0.6x106 CK13BA411 © 1

A
Spare coil CK07BA4 C04255 © 1
B CK08BA4
CK13BA4
C04787 ©
C08998 ©
1
1
Control circuit with incorporated rectifier bridge CK13BA4 C09120 © 1

Coil CK07BE4 KB5E © 1


C CK08BE4 ... CK95BE4, CK12BE4
CK10CE4 ... CK11CE4
KB6E ©
KB7E ©
1
1
Electronic module CK07BE4 KM5E © 1
CK08BE4 ... CK95BE4, CK12BE4 KM6E © 1
CK10CE4 ... CK11CE4 KM7E © 1
D
(1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and
frequency of the control circuit (see C.18).

F Auxiliary instantaneous contact block


Number of Contacts Cat. no. Ref. no. Pack
contacts
•3 •1 •7 •5
G
•4 •2 •8 •6
Side mounting 2 2 0 0 0 BCLL20 104706 10
H 2 1 1 0 0 BCLL11 104707 10

combinations of more than 2 blocks


2 2 0 0 0 BRLL20 104704 10
2 1 1 0 0 BRLL11 104705 10
I 2 0 2 0 0 BRLL02 106622 10

For reference numbers,


see chapter X, pg. X.4

C.20
Series CK
Accessories
For use Mounting Voltage Ue Cat. no. Ref. no. Pack
with:

Transient voltage Fixation to the coil terminals, that allows simultaneous use with the auxiliary contact blocks.
suppressor CK75 ... CK08 AC 24V - 48V BSLR3G 104716 10
CK75 ... CK08 AC 50V - 127V BSLR3K 104717 10
CK75 ... CK08 AC 130V - 240V BSLR3R 104718 10
CK75 ... CK08 AC 227V - 500V BSLV3U 110836 10

CK85 ... CK13 AC 24V KRC24 104760 10


CK85 ... CK13 AC 260V KRC48/260 104761 10
CK85 ... CK13 AC 415V KRC380/415 104762 10

3P and 4P contactors
Mechanical CK07B ... CK12 Horizontal BEKH 104763 1
interlock
CK07B ... CK95 Vertical BEKVS 1 104786 1
CK10C ... CK12B Vertical BEKVA 1 104785 1
CK13 Vertical BEKV 104764 1

Pole terminal CK75C ... CK08C 1 pole. VDE0106 CM1CA5F 105200 1


protection CK85B ... CK12B 1 pole. VDE0106 Contactors 3P C09476 104766 6 B
CK08B ... CK12B 1 pole. VDE0106 Contactors 4P C09479 204800 8

CK75C ... CK08C 1 pole IPXXB PTPCK75 103747 1(1)


CK85B ... CK95B 1 pole IPXXB PTPCK95 103748 3(2)
CK10C ... CK12B 1 pole IPXXB PTPCK11 103749 1(1) C

(1) One phase


(2) Three pole
D

E
Spares
For use Type Cat. no. Ref. no. Pack
with: F
Contact kits One set consists of two fixed contacts, one moving contact and accessory parts.
When contact replacement is needed, it is recommended to replace all the contacts at the same time.
CK07B NA V1107BA 113612 1
CK75C
CK08C
NA
NA
V1175CA
V1108CA
113613
113614
1
1
G
CK08B NA Contactors 4P V1108B4 113505 1
CK85B NA V1185BA 113615 1
CK09B NA V1109BA 113616 1
CK09B
CK95B
NA
NA
Contactors 4P V1109B4
V1195BA
113899
113617
1
1
H
CK10C NA V1110CE 113618 1
CK11C NA V1111CE 113619 1
CK12B NA V1112BA 113620 1
CK13B NA V1113BA 113621 1 I

C.21
Series M
Notes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contactors

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

C.22
Series M
Technical data
General Shock resistance (IEC 68-2-27)
MC0... MC1... MC2... Continuously closed (at 0.8Us)
Rated thermal current Ith θ ≤ 60º(1) (A) 20 20 20 Admissible acceleration 25 g
Rated operational current Ie(2) (A) 6 9 12 Impulse duration 11 ms
(3 x 440V, 50/60Hz, AC-3) Continuously opened (no voltage)
Admissible acceleration 20 g

3P and 4P minicontactors
Maximum number of poles 4 4 4
Rated insulation current Ui (V) 750 750 750 Impulse duration 11 ms
Rated operational current Ue (V) 690 690 690
(1) Insulated terminal type B 2.8 x 0.8 with wire 1 mm2:
Ie = 8A, design DIN 46 247
(2) Max.operational current AC3, 3 -phase≤ 440V, Vibration resistance (IEC 68-2-6)
according to IEC 947-4-1 Continuously closed (at 0.8Us)
Admissible acceleration 15 g
Sweep between 10 - 200 Hz

Conformity to standards Continuously opened (no voltage)


Admissible acceleration 5g (AC) - 35g (DC)
IEC/EN 60947-1 CSA C22.2/14 SEV 10254 Sweep between 10 - 200 Hz
IEC/EN 60947-4-1 CENELEC HD 419 JIS C8325
IEC/EN 60947-5-1 VDE 0660 JEM 1038
EN 50003 NFC 63110 NEMA ICS-1
EN 50005 BS 4794 UL 508
Mounting positions
EN 50012

Approvals
cULus NEMKO SEMKO
A
SETI DEMKO RINA
IMQ
Lloyd’s Register Bureau Veritas With the same pick-up and drop-out voltage
With the same rated power
B

Ambient conditions -7% of connection voltage


Storage temperature -55ºC to +80ºC +4% of disconnection voltage
With the same rated power
C
Operation temperature -40ºC to +60ºC
Altitude up to 3000m Nominal values
from 3000 up to 4000m 90%Ie 80%Ue 7% of connection voltage
from 4000 up to 5000m 80%Ie 75%Ue +4% of disconnection voltage D
With the same rated power

Climatic resistance E
Continuous tests 40 / 125 / 56
Cold (72h) Terminal capacity
Temperature -40ºC Terminal with M3.5 screw Tightening torque
Dry heat (96h)
Temperature +125ºC
(with pozidrive head and safety flange) 0.8 Nm - 7 Lb/in F
Solid wire mm2 0.75 to 2 x 2 w.
Relative humidity < 50% Flexible wire without terminal mm2 0.75 to 2.5 x 2 w.
Humid heat (56h) Flexible wire without terminal with cap mm2 0.75 to 2.5 x 1 w.
Temperature
Relative humidity
+40ºC
95% Ring terminal
mm2 0.75 to 1 x 2 w.
0.8 Nm - 7 Lb/in
G
Cyclic tests
First half-cycle (12h)
Low temperature
Relative humidity
+25ºC
93% H
Second half-cycle (12h)
Low temperature +55ºC
Relative humidity 95%
Number of consecutive cycles 6 Faston terminal 2.8 - 2 insulated terminals mm2 1 x 2 w. I
Terminal for printed circuit (Ø of PCB hole) 1.8 mm
Ring terminal cap 7.8 mm
Fork terminal cap 6.5 mm
X

C.23

32764_C22_C59_E.indd 23 11-07-2005 16:16:57


Series M
Control circuit
MC _ A... MC _ C... MC _ I... MC _ K... MC _ C...W

Rated insulation voltage (Ui) (V) 750 750 750 750 750
Standard voltages (Us)
50Hz (V) 24 ... 690 – – – –
60Hz (V) 6 ... 600 – – – –
DC (V) – 6 ... 440 24 24 12 ... 440
Operating voltages limits
Operating (1) xUs 0.8 ... 1.1 0.8 ... 1.1 0.8 ... 1.25 0.7 ... 1.25 0.7 ... 1.3
Drop-out xUs 0.35 ... 0.55 0.15 ... 0.4 0.15 ... 0.3 0.15 ... 0.35 0.15 ... 0.3
Operating voltages limits with coil 50/60 Hz
Operating xUs 0.8 ... 1.1 – – – –
Drop-out xUs 0.35 ... 0.55 – – – –
Consumption
50 or 60Hz - monofrequency coil
Pick-up (VA) 26 – – – –
Seal (VA) 4 – – – –
Contactors

50/60Hz - bifrequency coil


Pick-up (VA) 32 – – – –
Seal (VA) 6 – – – –
DC (W) – 3 1.2 2 4
Power factor
Magnetic circuit open (cos ϕ) 0.8 – – – –
Magnetic circuit closed (cos ϕ) 0.35 – – – –
Power dissipation (W) 1.4 3 1.2 2 4
Opening and closing times
Values between ± %Us % +10 ... -20 +10 ... -20 +25 ... -30 +25 ... -30 +30 ... -30
A Making time on energisation NO (ms) 6 ... 13 22 ... 36 30 ... 70 20 ... 50 17 ... 28
Making time on de-energisation NC (ms) 8 ... 16 9 ... 12 9 ... 16 9 ... 16 9 ... 12
Breaking time on energisation NC (ms) 5 ... 11 18 ... 27 20 ... 45 18 ... 35 12 ... 25
Breaking time on de-energisation NO (ms) 6 ... 13 5 ... 7 5 ... 9 5 ... 9 5 ... 7
B Values at Us
Making time on excitation NO (ms) 7 ... 12 24 ... 27 25 ... 45 25 ... 40 11 ... 23
Making time on desexcitation NC (ms) 8 ... 16 9 ... 11 9 ... 16 9 ... 16 9 ... 11
Breaking time on excitation NC (ms) 6 ... 10 20 ... 26 25 ... 35 20 ... 30 15 ... 21

C Breaking time on desexcitation NO


Maximum time without voltage
(ms)
(ms)
6 ... 13
3
5 ... 8
3
5 ... 9
3
5 ... 8
3
5 ... 8
3
Mechanical endurance
Monofrequency coil 106 ops. >15 – – – –
Bifrequency coil 106 ops. >10 – – – –
D DC 106 ops. – 10 10 10 10
Maximum rate
No load Monofrequency coil ops./h 9000 – – – –
Bifrequency coil ops./h 3600 – – – –
E DC ops./h – 9000 9000 9000 9000
AC1 and AC3 (at rated power) ops./h 1200 1200 1200 1200 1200
AC4 (at rated power) ops./h 300 300 300 300 300

C.24
Series M
Main circuit (poles) Electrical endurance
MC 0... MC1... MC2...
Category AC1
Rated insulation voltage (Ui) (V) 750 750 750
(acc. IEC 947-4)
Rated thermal current (lth) (A) 20 20 20 Number of

MC0...
MC1...
MC2...
θ ≤ 60º (1) operations
Frequency limits (Hz) 0...400 0...400 0...400

3P and 4P minicontactors
Making capacity (r.m.s.) Ue ≤ 690V 50/60Hz (A) 160 160 160
Breaking capacity (r.m.s.) Ue ≤ 440V (A) 106 106 106
Ue = 500V (A) 90 90 90
Ue = 690V (A) 80 80 90
Short-time current
0.3 sec. (A) 470 470 470
1 sec. (A) 250 250 250
5 sec. (A) 125 125 125
10 sec. (A) 95 95 95
30 sec. (A) 70 70 70
1 min. (A) 50 50 50
3 min. (A) 40 40 40
Recovery time min. 10 10 10
Protec. against short-circuits (IEC 947-4). w/o TOR
Coordination type “1” gL/gG (A) 32 32 32 Category AC3
Coordination type “2” gL/gG (A) 16 20 20
w/o welding contacts gL/gG (A) 12 16 16

MC0...
MC1...
MC2...
Number of
Circuit breaker rating (curve G CEE 19.1) 16 20 20
operations
Impedance per pole (mΩ) 1.5 1.5 1.5
Power dissipation per pole
AC1 (W) 0.6 0.6 0.6 A
AC3 (W) 0.06 0.128 0.228
Insulation resistance
Between adjacent poles (mΩ) > 10 > 10 > 10
Between pole and earth
Between input and output
(mΩ) > 10
(mΩ) > 10
> 10
> 10
> 10
> 10
B
Guaranteed no overlap
between NO and NC contacts
Space
Time
(mm)
(ms) > 2
1
>2
1 1
>2
C
(1) Insulated terminal type B 2.8 x 0.8 with wire 1 mm2 Ie = 8A
acc. to DIN 46247
Standard motor

D
power

Category AC4
F
MC1.../MC2...

Number of
operations

G
MC0...

X
Standard motor
power

C.25
Series M
Internal auxiliary contacts Tripping characteristics (DC)
MC0 / MC1 / MC2

Rated insulation voltage (Ui) IEC 60947-5 (V) 750 DC Inductive circuit. DC-13 L/R ≤ 100 ms
Rated thermal current (Ith) θ ≤ 60ºC (1) (A) 16 Electrical endurance 106 ops.
Making capacity according with IEC 60947-5-1
Ue ≤ 690 50-60 Hz (A) 160
Ue ≤ 440V DC (A) 160
Breaking capacity (r.m.s.) IEC 60947-5-1
AC-15
Ue ≤ 440V / 50-60 Hz (A) 106
DC-13
Ue ≤ 110V DC (A) 3
Ue = 220V DC (A) 1.2
Ue = 48V DC (A) 10
Minimum operational power (operational safety.) 5mA, 17V
Short-circuit protection (A) 10
(max.class gl fuse) w/o welding
Contactors

Insulation resistance

.
Between adjacent contacts (mΩ) > 10
Between contacts and earth (mΩ) > 10
Between input and output (mΩ) > 10
(1) 1 pole in series
(2) 2 poles in series
Guaranteed no overlap between NO and NC contacts
(3) 3 poles in series
Space (mm) 0,5
Minimal time (ms) >2
Impedance (mΩ) 2.3
Terminal capacity Same as DC Inductive circuit. DC-13 L/R ≤ 15 ms
main circuit Electrical endurance 106 ops.
A (1) Insulated terminal type B 2.8 x 0.8 with wire 1 mm2 Ie = 8A acc.
with DIN 46247

B
Tripping characteristics (AC)
C AC Operation AC-15 .
.
Electrical endurance
.

.
D .

(1) 1 pole in series


(2) 2 poles in series
E . (3) 3 poles in series

.
.
F . DC Inductive circuit. DC-13 L/R ≤ 1 ms
Electrical endurance 106 ops.
.

.
G

H
.
.
I .

.
X (1) 1 pole in series
(2) 2 poles in series
(3) 3 poles in series

C.26
Series M
Instantaneous auxiliary contact blocks Tripping characteristics (DC)
MACN..., MACL...

Rated insulation voltage (Ui) acc. IEC 60947-1 (V) 750 DC Inductive circuit. DC-13 L/R ≤ 100 ms
Rated thermal current (Ith) θ ≤ 60ºC (1) (A) 10 Electrical endurance 106 ops.
Making capacity (r.m.s.) according with IEC/EN 60947-5-1
AC-15 Ue ≤ 220V 50/60 Hz (A) 73
Ue = 380V 50/60 Hz (A) 38

3P and 4P minicontactors
Ue = 690V 50/60 Hz (A) 22
DC-13 Ue ≤ 100V DC (A) 2.6
L/R=100ms Ue = 220V DC (A) 1
Ue = 440V DC (A) 0.6
Breaking capacity (r.m.s.) acc. IEC/EN 60947-5-1
AC-15 Ue ≤ 220V 50/60 Hz (A) 73 .
Ue = 380V 50/60 Hz (A) 38 .
Ue = 690V 50/60 Hz (A) 22 .
DC-13 Ue ≤ 100V DC (A) 2
LR=100ms Ue = 220V DC (A) 0,8 .
Ue = 440V DC (A) 0.4 .
Rated voltage and rated current Ue-Ie
AC-15 according to IEC 60947 120V - 6A (1) 1 pole in series
230V - 6A (2) 2 poles in series
400V - 4A (3) 3 poles in series
500V - 1A
600V - 1A
according to UL, CSA A600
DC-13 according to IEC 60947 24V - 4A DC Inductive circuit. DC-13 L/R ≤ 15 ms
48V - 2A Electrical endurance 106 ops.
110V - 0.7A
220V - 0.3A
A
440V - 0.1A
according to UL, CSA Q600
Minimum operational power (operational safety) 5 mA, 17V
Short-circuit protection (A) 10 B
(max. class gl fuse) w/o welding
Insulation resistance
Between adjacent contacts (mΩ) > 10
Between contacts an earth (mΩ) > 10
.
. C
Between input and output (mΩ) > 10 .
Guaranteed no overlap between NO and NC contacts
Space (mm) 0,5 .
Minimal time (ms) > 2
.
D
Impedance (mΩ) 2.4
Terminal capacity Same as main
circuit (1) 1 pole in series
(2) 2 poles in series
(1 Insulated terminal type B 2.8 x 0.8 with wire 1 mm2 Ie = 8A acc.
with DIN 46247
(3) 3 poles in series E

Tripping characteristics (AC)


DC Inductive circuit. DC-13 L/R ≤ 1 ms F
Electrical endurance 106 ops.

AC Operation AC-15
Electrical endurance G

H
.
.
. .
I
. .
.
.
.

. (1) 1 pole in series


X
(2) 2 poles in series
. (3) 3 poles in series

C.27
Series M
Electronic timer block
MREBC...

Rated insulation voltage (Ui) (V) 750


Rated thermal current (Ith) θ ≤ 60ºC (1) (V) 0.55
Supply voltage (AC and DC) (V) 24 to 250
Operating limits 0.80 to 1.1 Us
(0.85 to 1.1 Us to 12V)
Voltage drop (V) < 3
Maximum load current at :
20ºC (A) 0.9
40ºC (A) 0.72
60ºC (A) 0.55
Minimum load for safe operation (A) > 10
Maximum current (A) 10A per 40 ms
Leakage current at 220V (mA) <5
Operational current
AC-15 (A) 0.7
Contactors

DC-13 (A) 0.9


Timing range (delay ON) (s) 0.5 to 60 (± 6 s)
Rearrangement time (ms) < 100
Repeatibility (accuracy) (%) ±1
Ambient temperature
storage (ºC) –55 to + 80
operation (ºC) –5 to + 60
Degree of protection IP20
Mounting positions Any
Terminals : 2 free cables 1 mm2 (AWG 17)

A 250 mm

E Contact sequence
Main Main Auxiliary Auxiliary
contact (NO) contact (NC) contact (NO) contact (NC)
F
Three-pole minicontactor
G
0 2 3.5 0 2.3 3.5
MC...310...

0 2 3.5
H MC...301... 0 1.2 3.5

Four-pole minicontactor

I MC...400...
0 2 3.5

0 2 3.5 0 1.2 3.5


MC...B00...

X MC...A00...
0 1.2 3.5

Auxiliary contact block

0 2.1 3.5 0 1 3.5


MAC...

0 2.1 3.5 0 1 3.5


MAR...

C.28

32764_C22_C59_E.indd 28 11-07-2005 16:17:01


Series M
Terminal numbering in accordance with EN 50012
Final structure of the contactor Auxiliary contactors Possible basic contactors
Combination + Auxiliary contact blocks to be added

Description NO NC
Without auxiliary contact blocks

3P and 4P minicontactors
0 1 MC_A301A...
01E

1 0 MC_A310A...
10E

Auxiliary contact blocks front mounted with two or four contacts

1 1 MC_A310A...
11E
+ MACN211A

2 1 MC_A310A...
21E
+ MACN211A

1 2 MC_A310A...
12E
+ MACN202A

3 1 MC_A310A...
31E
+ MACN431A

4 1 MC_A310A...
41E
+ MACN431A A
2 2 MC_A310A...
22E
+ MACN422A

MC_A310A...
B
32E 3 2
+ MACN422A

13E 1 3 MC_A310A...
+ MACN413A
C
2 3 MC_A310A...
23E
+ MACN413A
D
Auxiliary contact blocks lateral mounted with one contact

1 1 MC_A310A...
11E
+ MACL101A
E
2 1 MC_A310A...
21E
+ MACL101A + MACL110A

MC_A310A...
F
12E 1 2
+ MACL101A + MACL101A

C.29
Series M
Terminal numbering Base four-pole contactors. (EN 50005)

Basic three-pole contactors. (EN 50012) MC _ _ 400A _ MC _ _ B00A _

MC _ _ 310A _ MC _ _ 301A _

MC _ _ A00A _

Instantaneous auxiliary contact


blocks. (EN 50012)
Contactors

MACL110A _ MACL101A _ MACN211A_

Instantaneous auxiliary contact


blocks. (EN 50005)
MARL110A_ MARL101A_ MARL110A_S

MACN202A_ MACN431A_ MACN422A_

A
MARL101A_S MARN220A_ MARN211A_

B MACN413A_

C
MARN202A_ MARN440A_ MARN431A_

D
Instantaneous auxiliary contact
blocks. (EN 50005)
E MARL110A_S MARL101A_S MARN220A_ MARN422A_ MARN413A_ MARN404A_

G MARN211A_ MARN202A_ MARN440A_

Voltage suppressor block


H MP0AAE _ MP0CAE3

MARN431A_ MARN422A_ MARN413A_


I

MP0CAE4
X
MARN404A_

C.30

32764_C22_C59_E.indd 30 11-07-2005 16:17:04


Series CL
Conformity to standards Climatic resistance (IEC 68-2)
IEC/EN 60947-1 EN 50005 UNE 20109 Continuous tests 40 / 125 / 56 Cyclic test (6 cycles)
IEC/EN 60947-4-1 CENELEC HD419 BS 5424 & 775 Cold (72h) Humid heat
IEC/EN 60947-5-1 NF C63-110 NEMA ICS 1 Temperature -40ºC First half-cycle (12h))
Dry heat (96h) Low temperature +25ºC
UL 508 ASE 1025 VDE 0660/102
Temperature +125ºC Relative humidity 93%
CSA 22.2/14
Relative humidity < 50% Second half-cycle (12h)
Humid heat (56h) Low temperature +55ºC
Approvals Temperature +40ºC Relative humidity 95%
cULus RINA Relative humidity 95%
SETI IMQ (up to Ith:32A)

3P and 4P contactors
Lloyd’s Register Bureau Veritas Mounting positions
Ambient conditions
Storage temperature -55ºC to +80ºC
Operation temperature -40ºC to +60ºC
Altitude up to 3000m Nominal values
from 3000 up to 4000m 90%Ie 80%Ue
from 4000 up to 5000m 80%Ie 75%Ue

With the same pick-up and drop-out voltage


With the same rated power

Terminal capacity and tightening torque


CL00 ... CL02 CL25 CL03 ...CL04 CL45 CL05 ... CL08 CL09 ... CL10

Solid, stranded and finely stranded 2 x 0.5 ... 2.5 2 x 0.5 .. 2.5 – – – –
without end sleeve (mm2) 2 x 2.5 ... 6 2 x 2.5 ... 10 – – – – A
Finely stranded with or 2 x 1 ... 2,5 2 x 1 ... 2,5 – – – –
without end sleeve (mm2) 2 x 2.5 ... 6 2 x 2.5 ... 10 – – – –
AWG wires 2 x 20 ... 12 2 x 20 ... 8 – – – –
Tightening torque Nm
Lb x in.
1.6
15
2.2
20








B
Solid, stranded and finely stranded
without end sleeve (mm2) – – 0.75 ... 16 0.75 ... 16 1 ... 35 1.5 ... 50
Finely stranded with end sleeve (mm2)
Finely stranded w/o end sleeve (mm2)




0.75 ... 16
1 ... 16
0.75 ... 16
1 ... 16
1 ... 35
1 ... 35
1.5 ... 50
1.5 ... 50
C
AWG wires – – 18 ... 6 18 ... 6 16 ... 2 16 ... 2
Tightening torque Nm – – 1,4 1,8 4 5,6
Lb x in. – – 12 16 35 50
Solid (mm2) – – 0.75 ... 16 0.75 ... 16 1 ... 16 4 ... 35 D
Stranded (mm2) – – 0.75 ... 16 0.75 ... 16 1 ... 25 4 ... 35
Finely stranded w/o end sleeve (mm2) – – 0.75 ... 16 0.75 ... 16 1 ... 25 4 ... 35
Finely stranded with end sleeve (mm2) – – 1 ... 16 1 ... 16 1 ... 25 4 ... 35
AWG wires – – 18 ... 6 18 ... 6 16 ... 4 10 ... 1 E
Tightening torque Nm – – 1.4 1.8 4 5.6
Lb x in. – – 12 16 35 50
Solid, stranded and finely stranded – – Max. 16 Max. 16 Max. 50 ... 4 Max. 50 ... 35
without end sleeve (mm2) – – Max. 25 ... 16 F
Finely stranded w/o end sleeve (mm2) – – Max. 25 ... 16
Finely stranded with end sleeve (mm2) – – Max. 25 ... 25
AWG wires – – Max. 6 Max. 6 Max. 2 ... 12 Max. 1

Tightening torque Nm



– 1.4 1.8
Max 4 ... 4
4 5.6
G
Lb x in. – – 12 16 35 50
Ring terminals Øi 3,6 4,2 4.2 4.2 6.2 6.2
(acc. with IEC/EN 60947-1)
Tightening torque Nm
A 8
1,6
10
1,4
10
1.4
10
1.4
12.5
3
12.5
3
H
Lb x in. 15 12 12 12 26 26

C.31
Series CL
Power circuit
CL00 CL01 CL02 CL25 CL03 CL04 CL45 CL05 CL06 CL07 CL08 CL09 CL10

Three pole version


Rated thermal current Ith at θ ≤ 55ºC (A) 25 25 32 45 45 60 60 90 110 110 140 140
Rated operational current Ie AC-3 (A) 9 12 18 25 25 32 40 50 65 80 95 105
Rated operational voltage Ue (V) 690 690 690 690 690 690 690 690 690 690 690 690

Four pole version


(4NO and 2NO+2NC)
Rated thermal current Ith at θ ≤ 55ºC (A) 25 32 45 60 90 110 110 140
Rated operational voltage Ue (V) 690 690 690 690 690 690 690 690

Three and four pole


version
Contactors

Rated insulation voltage Ui (V) 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
Maximum continuous current AC-1 (A) 25 25 32 45 45 60 60 90 90 110 110 140 140
Frequency limits (Hz) 25..400 25..400 25..400 25..400 25..400 25..400 25..400 25..400 25..400 25..400 25..400 25..400 25..400
Making capacity (RMS) (IEC 947) (A) 450 450 450 450 550 550 550 1000 1000 1000 1000 1280 1280
Breaking capacity (RMS) (IEC 947)
Ue ≤ 400V (A) 250 250 250 350 450 450 450 920 920 920 920 1050 1050
Ue = 500V (A) 250 250 250 320 450 450 450 920 920 920 920 1050 1050
Ue = 690V (A) 130 130 130 170 205 205 205 780 780 780 780 950 950
Short-time current
1 sec. (A) 455 455 570 630 1010 1010 1265 1580 1580 2530 2530 3300 3300
A 5 sec.
10 sec.
(A)
(A)
205
144
205
144
254
180
280
200
450
320
450
320
450
400
565
500
710
500
1130
800
1130
800
1485
1050
1485
1050
30 sec. (A) 85 85 104 115 185 185 230 290 290 460 460 600 600
1 min. (A) 60 60 74 80 130 130 165 205 205 325 325 430 430
3 min. (A) 35 35 46 50 90 90 100 120 120 185 185 250 250
B Recovery time (min.) 10 10 10 10 10 10 10 10 10 10 10 10 10
Protec. against short-circuit with fuses
without TOR
Coordination type “1”
C gL/gG (A) 50 50 63 63 100 100 125 200 200 200 200 250 250
Coordination type “2”
gL-gG (A) 25 35 35 50 63 63 80 100 100 125 125 160 200
Without welding
D gL-gG (A) 10 10 25 35 35 35 50 80 80 100 100 140 160
Impedance per pole (mΩ) 2.35 2.35 2.41 1.65 1.28 1.28 0.95 0.85 0.85 0.86 0.86 0.76 0.76
Power dissipation per pole
AC-1 (W) 1.47 1.47 2.46 3.34 2.59 4.6 3.42 6.89 6.86 10.40 10.40 14.89 14.89
E AC-3 (W) 0.19 0.34 0.78 1.03 0.80 1.31 1.52 1.36 2.12 3.63 5.5 6.86 8.37
Insulation resistance
Between adjacent poles (mΩ) >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10
Between poles and earth (mΩ) >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10
F Between input and output (mΩ) >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10

C.32
Series CL
Control circuit
CL00 ... CL25 CL03 ... CL45 CL05 ... CL08 CL09 ... CL10

Alternating current
Rated insulation voltage Ui (V) 1000 1000 1000 1000
Standard voltages Us 50 Hz (V) 24...690 24...690 24...690 24...690
Standard voltages Us 60 Hz (V) 24...600 24...600 24...600 24...600
Voltage operating limits monofrequency coils
Operating xUs 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1
Pick-up xUs 0.6...0.8 0.65...0.8 0.65...0.8 0.65...0.8

3P and 4P contactors
Seal xUs 0.35...0.55 0.4...0.6 0.4...0.6 0.4...0.6
Voltage operating limits 50/60 Hz coils
Operating 50 Hz xUs 0,8...1,1 0.8...1.1 0.8...1.1 0.8...1.1
Operating 60 Hz xUs 0,85...1,1 0.85...1.1 0.85...1.1 0.85...1.1
Pick-up 50 Hz xUs 0,5...0,8 0.6...0.8 0.6...0.8 0.6...0.8
Pick-up 60 Hz xUs 0,65...0,85 0.7...0.85 0.7...0.85 0.7...0.85
Seal 50 Hz xUs 0,3...0,55 0.35...0.60 0.35...0.60 0.35...0.60
Seal 60 Hz xUs 0,35...0,65 0.4...0.6 0.4...0.6 0.4...0.6
Consumption monofrequency coils
Magnetic circuit closed (VA) 6 9 15.5 15.5
Magnetic circuit opened (VA) 48 88 190 190
Consumption bifrequency coils
Magnetic circuit closed (50 Hz/60 Hz) (VA) 6.8 / 5.6 11.4 / 9.5 20 / 16.6 20 / 16,6
Magnetic circuit opened (50 Hz/60 Hz) (VA) 53 / 44 120 / 100 245 / 204 245 / 204
Thermal power dissipation (50 Hz/60 Hz) (W) 2.2 / 1.8 3.2 / 2.6 5.2 / 4.3 5.2 / 4.3
Power factor
Magnetic circuit closed cos ϕ 0.33 0.28 0.26 0.26
Magnetic circuit opened cos ϕ 0.84 0.73 0.54 0.54
Opening and closing times A
Values between + 10 % Us and – 20 % Us
Making time on energisation (NO) (ms) 6...20 7...25 9...35 9...35
Breaking time on de-energisation (NO) (ms) 6...13 5...25 9...15 9...15
Values at Us B
Making time on energisation (NO) (ms) 8...20 10...19 15...30 15...30
Making time on de-energisation (NO) (ms) 6...13 5...25 9...15 9...15
Mechanical endurance
Monofrequency coils 106 ops. 15 15 15 15 C
Bifrequency coils (at 50 Hz) 106 ops. 10 10 8 8
Maximum rate
Monofrequency coils. No load ops./h 9000 9000 9000 5000
AC-1 at rated power ops./h 1200
1000
1200
1000
1200
1000
1200
750
D
AC-2 at rated power ops./h
AC-3 at rated power ops./h 1200 1200 1200 600
AC-4 at rated power ops./h 360 360 200 200
Bifrequency coils. No load ops./h 3600 3600 3600 3600
E
Coils with Coils with
electronic module wide voltage range
F
CL00D CL03D CL05E CL09E CL00D..W CL03D..W CL05D..W
... ... ... ... ... ... ...
CL25D CL45D CL08E CL10E CL25D..W CL45D..W CL10D..W
Direct current
Rated insulation voltage Ui (V) 1000 1000 1000 1000 1000 1000 1000
G
Standard voltages Us (V) 12...440 12...440 24...440 24...440 12...440 12...440 12...440
Operating limits
Operating
Pick-up
xUs
xUs
0.8...1.1 0.8...1.1
0.45...0.65 0.45...0.65
0.8...1.1
0.70...0.80
0.8...1.1
0.70...0.80
0.7...1.3 0.7...1.3
0.45...0.55 0.45...0.55
0.7...1.3
0.45...0.55
H
Drop-out xUs 0.15...0.3 0.15...0.3 0.4...0.6 0.4...0.6 0.15...0.3 0.15...0.3 0.15...0.3
Consumption
Magnetic circuit closed (W) 5.5 8 10 10 6.5 10.4 20
Magnetic circuit opened (W) 5.5 8 170 170 6.5 10.4 20 I
Opening and closing times
Values between + 10 % Us and – 20 % Us
Making time on energisation (NO) (ms) 35...65 35...70 60...80 60...80 26...55 30...65 64...133
Breaking time on de-energisation (NO) (ms) 6...15 40...65 40...50 40...50 6...15 5...10 20...23 X
Values at Us
Making time on energisation (NO) (ms) 35...45 40...55 50...60 50...60 35...45 40...55 75...95
Breaking time on de-energisation (NO) (ms) 7...12 30...65 55...60 55...60 7...12 6...8 20...22
Mechanical endurance 106 ops. 15 15 12 12 15 15 12
Maximum rate
No load ops./h 3600 3600 2500 2500 3600 3600 3600
AC1 and AC3 at rated power ops./h 1200 1200 1200 600 1200 1200 1200
AC4 at rated power ops./h 360 360 200 200 360 360 200

C.33
Series CL
Electrical endurance

Mixed category AC4 / AC3


Electrical endurance for mixed category
(AC-3/AC-4) is calculated with the following Electrical endurance Electrical endurance (AC-3)
formula : = % oper AC-4
(AC-3/AC-4)
1 +
100
X ( Elec.endur. (AC-3)
Elec.endur.(AC-4)
-1 )

Category AC1
Contactors

Number of
operations

B Ic=Ie
for all voltages

D Category AC2

E
Number of
operations

X
.

.
.

Rated motor
.
.

power
(Ic = 2,5 Ie)
.

.
.

.
.

.
.

.
.

.
.

C.34
Series CL

Category AC3

Number of

3P and 4P contactors
operations

A
.

.
.

.
.

Rated motor
.

power
(Ic = Ie)
B
.

.
.

.
.

.
.

.
.

Category AC4 D

E
Number of
operations

X
.

.
.

Rated motor
.
.

power
(Ic = 6 Ie)
.

.
.
.

.
.
.
.

.
.
.

C.35
Series CL
Internal auxiliary contacts
CL00 ... CL02 CL03 ... CL04
Rated insulation voltage Ui according to IEC 60947 (V) 1000 1000
Rated thermal current Ith a θ ≤ 55ºC (A) 20 20
Making capacity (r.m.s.) acc. to IEC 60947
AC-15 Ue ≤ 400V, 50/60 Hz (A) 250 250
DC-13 Ue ≤ 220V DC (A) 250 250
Breaking capacity (r.m.s.) acc.to IEC 60947
AC-15 Ue ≤ 400V, 50/60 Hz (A) 250 250
DC-13 Ue ≤ 220V DC (A) 2 2
AC-15 Rated voltage and current Ue-Ie according to IEC 110/120V-10A 220/230V-10A 110/120V-10A 230/220V-10A
400/380V-6A 415/450V-5A 400/380V-6A 415/450V-5A
500V-4A 690/660V-2A 500V-4A 690/660V-2A
according to UL, CSA A600 A600
DC-13 Rated voltage and current Ue-le according to IEC 24V-6A 48V-4A 24V-6A 48V-4A
110V-2A 220V-0.7A 110V-2A 220V-0.7A
440V-0.35A 440V-0.35A
Contactors

according to CSA P600 P600


Electrical endurance ops. 106 106
Minimum operational power (operational safety) 17V - 5mA 17V - 5mA
Short-circuit protect. Max.fuse class gl-gG without welding (A) 10 10
Insulation Between contacts (mΩ) > 10 > 10
resistance Between contacts and earth (mΩ) > 10 > 10
Between input and output (mΩ) > 10 > 10
Guaranteed no overlap between NO and NC contacts
Space (mm) 1.3 2.6
Time (ms) 1.5 1.5
Impedance of the contacts (mΩ) 1.28 1.28
A

B
Auxiliary contact blocks
Instantaneous Timed blocks
C BCLF..., BCRF..., BCLL..., BRLL... BTLF..., BTRF...

Rated insulation voltage Ui according to IEC 60947 (V) 1000 1000


Rated thermal current lth at θ ≤ 55ºC (A) 10 10
Making capacity (Ieff) according to IEC 60947
D AC-15 Ue ≤ 400V, 50/60 Hz (A) 90 90
DC-13 Ue ≤ 220V DC (A) 90 90
Breaking capacity (Ieff) according to IEC 60947
AC-15 Ue ≤ 400V, 50/60 Hz (A) 60 60
E DC-13 Ue ≤ 220V, DC (A) 0.95 0.95
AC-15 Rated voltage and current Ue-Ie according to IEC 120/110V-6A 230/220V-6A 120/110V-6A 230/220V-6A
400/380V-4A 440/415V-3.5A 400/380V-4A 440/415V-3.5A
500V-2.5A 690/660V-1.5A 500V-2.5A 690/660V-1.5A
F according to UL, CSA A600 A600
DC-13 Rated voltage and current Ue-Ie according to IEC 24V-4A 48V-2A 24V-4A 48V-2A
110V-0.7A 220V-0.3A 110V-0.7A 220V-0.3A
440V-0.15A 440V-0.15A
G Electrical endurance
according to UL, CSA
106 ops.
Q600
1
Q600
1
Mechanical endurance 106 ops. 10 5
Minimum operational current (operational safety) 17V - 5mA 17V - 5mA

H Short-circuit protect. Max.fuse class gl-gG without welding


Insulation Between contacts
(A)
(mΩ)
10
> 10
10
> 10
resistance Between contacts and earth (mΩ) > 10 > 10
Between input and output (mΩ) > 10 > 10
Guaranted no overlap between NO and NC contacts
I Space (mm) 1.3 1.3
Time (ms) 1.5 5
Impedance of the contacts (mΩ) 1.28 1.28
Timing (ambient temperature between – 25ºC and + 55ºC)
X Accuracy – ± 5%
Loss of accuracy 0.5 x 106 ops. – + 20%
Loss of accuracy per rise ºC (0 - 55ºC) – + 0.75% per ºC

C.36
Series CL
Mechanical latch blocks
RMLF...
Rated insulation voltage Ui 1000 V
Standard voltages Us : 50 to 60 Hz and DC 24...690 V
Operating limits 0.75...1.1 xUs
Consumption for unlatching (auto cut-out)
24 to 72 V 210 W / VA
110 to 440 V 130 W / VA
Electrical unlatching control (1)
Minimum impulse 10 ms

3P and 4P contactors
Maintained auto cut-out by integral contact
Manual unlatching control by local push-button
Electrical making control
Minimum pulse 40 ms auto cut-out by integral contact
Manual making control by local push-button
Auxiliary contact NC
Utilisation AC-15 according to IEC 120V - 6A 500V - 1.5A
230V/220V - 4A 690V/660V - 1A
400V/380V - 2.5A
according to UL/CSA A600
Utilisation DC-13 according to IEC 24V - 3A 220V - 0.3A
48V - 1.5A 400V - 0.15A
110V - 0.6A
according to UL/CSA Q600
Mechanical endurance
CL00...CL45 3 million (1200 ops./h)
CL05...CL10 0.1 million (300 ops./h)
Wiring diagram Alternating current
A

B
Alternating current / Direct current

C
(1) The contactor coil and the unlatch control must not be energised simultaneously
D

E
Terminal capacity
Terminal: screw Terminal: ring terminal
BCLF, BCLL, BTLF y RMLF BCRF, BTRF
F
Solid 2 x 0.5 to 2.5 or 1 x 4
Stranded and finely stranded without end sleeve 2 x 0.5 to 2.5 or 1 x 4
Finely stranded with end sleeve 2 x 0.5 to 2.5 or 1 x 4
AWG wires, solid and stranded 12 - 22 AWG 75ºC G
Tightening torque 1.1 Nm / 10 Lb x in.
Ring terminal Øi 3.6 min.
A 6.5 max.
Tightening torque 0.8 Nm / 7 Lb x in. H

C.37
Series CL
Contact sequence
Basic contactor Auxiliary contact blocks Auxiliary contact blocks
Front mounted Lateral mounted

BCLF 10 BCLF 01 BCLL 20 BCLL 11


BCRF 10 BCRF 01 BRLL 20 BRLL 11

Three pole CL00... 0 3.3 0 3.2 4.7 0 1.4 0 3.2 0 3.2 4.7
contactors CL01...
3 NO CL02...
1.4
CL25... 0 3 0 3.7 5.1 0 1.6 5.1 0 3.7 0 3.7 5.1

1.6
CL03... 0 4 0 3.7 0 1.6 5.6 0 3.7 0 3.7 5.6
CL04...

1.6
Contactors

CL45... 0 4.3 0 3.7 6.5 0 1.6 6.5 0 3.7 0 3.7 6.5

1.6
CL06... 0 5.4 8 0 3.7 8 0 1.6 8 0 3.7 8 0 3.7 8

1.6
CL07... 0 4.8 8 0 3.7 8 0 1.6 8 0 3.7 80 3.7 8
CL08...

A 0 3.7 8 0
1.6
3.7 8
CL09... 0 5.6 8 0 3.7 8 0 1.6 8

1.6
B CL10... 0 5.6 8 0 3.7 8 0 1.6 8 0 3.7 8 0 3.7 8

1.6
C Four pole CL01... 0 3.3 4.7 0 3.2 4.7 0 1.4 4.7 0 3.2 4.7 0 3.2 4.7
contactors CL02...
4 NO 1.4

D CL03...
CL04...
0 4 5.6 0 3.7 0 1.6 0 3.7 5.6 0 3.7 5.6

1.6
CL05... 0 5.4 8 0 3.7 8 0 1.6 8 0 3.7 80 3.7 8
E
1.6
CL07... 0 4.8 8 0 3.7 8 0 1.6 8 0 3.7 8 0 3.7 8

F
1.6
CL09... 0 5.6 8 0 3.7 8 0 1.6 8 0 3.7 8 0 3.7 8

G 1.6
Four pole CL01... 0 3.3 4.7 0 3.2 4,7 0 1.4 0 3.2 4.7 0 3.2 4.7
contactors CL02...
H 2 NO + 2 NC 1.6 1.4
CL03... 0 4 5.6 0 3.7 0 1.6 0 3.7 5.6 0 3.7 5.6
CL04...

I 1.5 1,6
CL05... 0 5.4 8 0 3.7 8 0 1.6 8 0 3.7 8 0 3.7 8

3.7 1.6
X CL07... 0 4.8 8 0 3.7 8 0 1.6 8 0 3.7 80 3.7 8
CL08...
4.3 1.6

C.38
Series CL
Terminal numbering
Three-pole and four-pole AC contactors
CL00A300_ _ ... CL10A300_ _
CL25D300_ _ ... CL45D300_ _ CL00_310_ _ ... CL02_310_ _ CL00_301_ _ ... CL02_301_ _
CL06E300_ _ ... CL10E300_ _ CL03_310_ _ ... CL04_310_ _ CL03_301_ _ ... CL04_301_ _ CL45A311_ _ ... CL10A311_ _

3P and 4P contactors
CL00A400_ _ ... CL08A400_ _ CL01AB00_ _ ... CL08AB00_ _
CL01D400_ _ ... CL04D400_ _ CL01DB00_ _ ... CL04DB00_ _
CL25_310_ _ CL25_301_ _ CL05E400_ _ ... CL09E400_ _ CL05EB00_ _ ... CL08EB00_ _

Auxiliary contact blocks. Front mounting Auxiliary contact blocks. Lateral mounting
BC_ F10 BC_ F01 BCLF10G BCLF01G BCLL20 BCLL11

A
BRLL20 BRLL11
Pneumatic timer blocks B
BT_F_C BT_F_D

Mechanical and mechanical/electrical interlock


Electronic timer blocks D
BETL_ _C BETL_ _D
BELA, BEL BELA02, BEL02

F
Voltage suppressor blocks
BSLR2, BSLR3 BSLDZ BSLV3 Mechanical latch block
IMRC IMD1Z IMV3 RMLF
c. alterna AC /DC G

H
Interface modules
IMRD, IMRG IMSSD IMRFD, IMRFG IMAMS
I

C.39
Series CL
Terminal numbering according to EN 50012
Auxiliary contacts Possible basic contactors
Combination + Auxiliary contacts blocks to be added

Description NO NC
Without auxiliary contact blocks

CL00_310_... - CL04_310_...
10E 1 0

CL00_301_... - CL04_301_...
01E 0 1

Front mounting auxiliary contact blocks with one contact each


Contactors

CL00_310_... - CL04_310_...
11E 1 1 + BC_F01

CL00_310_... - CL04_310_...
21E 2 1 + BC_F01 + BC_F10

CL00_310_... - CL04_310_...
12E 1 2 + BC_F01 + BC_F01
A
CL00_310_... - CL04_310_...
31E 3 1 + BC_F01 + BC_F10
B + BC_F10

CL00_310_... - CL04_310_...
41E 4 1 + BC_F01 + BC_F10
C + BC_F10 + BC_F10

CL00_310_... - CL04_310_...
22E 2 2 + BC_F01 + BC_F01
D + BC_F10

CL00_310_... - CL04_310_...
32E 3 2 + BC_F01 + BC_F01
E + BC_F10 + BC_F10

CL00_310_... - CL04_310_...
13E 1 3 + BC_F01 + BC_F01
F + BC_F01

CL00_310_... - CL04_310_...
23E 2 3 + BC_F01 + BC_F01
+ BC_F01 + BC_F10
G
Lateral mounting auxiliary contact blocks with two contacts each

CL00_300_... - CL45_300_...
H 11E 1 1 + BCLL11

CL00_300_... - CL45_300_...
I 31E 3 1 + BCLL11 + BCLL20

CL00_300_... - CL45_300_...
X 22E 2 2 + BCLL11 + BCLL11

The maximum number of auxiliary contacts is 4 for CL00 to CL25, 6 for CL03 -CL04 and 8 for CL45, CL06 to CL10.When using the pneumatic BTLF-block,
thesenumbers are reduced to two, resp .four.( 2 for CL00 to CL25, 4 for CL03 and CL04, etc.)

C.40
Series CL
Terminal numbering according to EN 50012 (continued)
Auxiliary contacts Possible basic contactors
Combination + Auxiliary contacts blocks to be

Description NO NC
Without auxiliary contact blocks

CL25_300_... - CL45_300_... CL06_300_... - CL10_300_...

3P and 4P contactors
Front mounting auxiliary contact blocks with one contact each

CL25_300_... - CL45_300_... CL06_300_... - CL10_300_...


10E 1 0 + BC_F10 + BC_F10

CL25_300_... - CL45_300_... CL06_300_... - CL10_300_...


01E 0 1 + BC_F01 + BC_F01

CL25_300_... - CL45_300_... CL06_300_... - CL10_300_...


11E 1 1 + BC_F10 + BC_F01 + BC_F10 + BC_F01

CL25_300_... - CL45_300_... CL06_300_... - CL10_300_...


21E 2 1 + BC_F10 + BC_F01 + BC_F10 + BC_F01
+ BC_F10 + BC_F10
A
CL25_300_... - CL45_300_... CL06_300_... - CL10_300_...
12E 1 2 + BC_F10 + BC_F01 + BC_F10 + BC_F01
+ BC_F01 + BC_F01
B
CL25_300_... - CL45_300_... CL06_300_... - CL10_300_...
31E 3 1 + BC_F10 + BC_F01 + BC_F10 + BC_F01
+ BC_F10 + BC_F10 + BC_F10 + BC_F10
C
CL06_300_... - CL10_300_...
41E 4 1 + BC_F10 + BC_F01 +
BC_F10
D
CL25_300_... - CL45_300_... CL06_300_... - CL10_300_...
22E 2 2 + BC_F10 + BC_F01 + BC_F10 + BC_F01
+ BC_F01 + BC_F10 + BC_F01 + BC_F10
E
CL06_300_... - CL10_300_...
32E 3 2 + BC_F10 + BC_F01 +
BC_F01
F
CL25_300_... - CL45_300_... CL06_300_... - CL10_300_...
13E 1 3 + BC_F10 + BC_F01 + BC_F10 + BC_F01
+ BC_F01 + BC_F01 + BC_F01 + BC_F01
G
CL06_300_... - CL10_300_...
23E 2 3 + BC_F10 + BC_F01 +
BC_F01
H
Lateral mounting auxiliary contact blocks with two contacts each

CL25_300_... - CL45_300_... CL06_300_... - CL10_300_...


11E 1 1 + BCLL11 + BCLL11 I
CL25_300_... - CL45_300_... CL06_300_... - CL10_300_...
31E 3 1 + BCLL11 + BCLL20 + BCLL11 + BCLL20 X
CL25_300_... - CL45_300_... CL06_300_... - CL10_300_...
22E 2 2 + BCLL11 + BCLL11 + BCLL11 + BCLL11

C.41
Series CK
Conformity to standards Mounting positions
IEC/EN 60947-1 NF C 63-110 BS 5424 & 775
IEC/EN 60947-4-1 ASE 1025 NEMA ICS 1
CENELEC HD 419 CSA 22.2/14 VDE 0660/102
UL 508 UNE 20109
EN 50005

Approvals
cULus RINA
NOM FI
With the same pick-up and drop-out voltage
Lloyd’s Register Bureau Veritas
With the same rated power

Ambient conditions
Storage temperature -55ºC to +80ºC
Operation temperature -40ºC to +60ºC
Altitude up to 3000m Nominal values
from 3000 up to 4000m 90%Ie 80%Ue
Contactors

from 4000 up to 5000m 80%Ie 75%Ue

Climatic resistance (IEC 68-2)


Continuous tests 40 / 125 / 56
Cold (72h)
Temperature -40ºC
Dry heat (96h)
Temperature +125ºC
Relative humidity < 50%
A Humid heat (56h)
Temperature +40ºC
Relative humidity 95%
Cyclical test
B First half-cycle (12h))
Low temperature +25ºC
Relative humidity 93%
Second half-cycle (12h)

C Low temperature
Relative humidity
+55ºC
95%
Number of consecutive cycles 6

D Terminal capacity and tightening torque


CK07B CK75C CK08B CK10C CK11C CK12B CK13B
CK08C CK95B

E Solid (mm2)
Finely stranded w/end sleeve (mm2)
1.5...95
2...35
Finely stranded w/o end sleeve(mm2) 2...50
Stranded (mm2) 1.5...95

F AWG wires
Tightening torque
(mm2)
(Nm)
16...00
8
(Lb x in 70
Finely stranded w/end sleeve(mm2) 1 x 120 1 x 240 2 x 185 2 x 240 – –
2 x 95 2 x 150
G AWG wires with end sleeve (mm2) 1 x 300 1 x 500 2 x 350
2 x 107 2 x 300 2 x 500 – –
Busbars 2 (25 x 5) 2 (25 x 5) 2 (35 x 10) 2 (35 x 10) 2 (35 x 10) 2 (60 x 10)
Tightening torque (Nm) 8 23 31.5 31.5 31.5 31.5
H (Lb x in)) 70 200 275 275 275 275

C.42
Series CK
Power circuit
CK75C CK08C CK85B CK09B CK95B CK10C CK11C CK12B CK13B
Three pole contactors
Rated thermal current Ith at θ ≤ 40ºC (A) 250 250 315 315 450 600 700 1000 1250
Rated operational current Ie AC-3 (A) 150 185 205 250 309 420 550 700 825
Rated operational voltage Ue (V) 1000 1000 1000 1000 1000 1000 1000 1000 1000
Rated insulation voltage Ui (V) 1000 1000 1000 1000 1000 1000 1000 1000 1000
Maximum continuous current AC-1 (A) 250 250 315 315 450 600 700 1000 1250
Frequency limits (Hz) 25...400 25...400 25...400 25...400 25...400 25...400 25...400 25...400 25...400
Making capacity (RMS) (IEC 947) (A) 1850 2200 2500 2500 3700 6500 6500 8400 8250

3P and 4P contactors
Breaking capacity (RMS) (IEC 947)
Ue ≤ 400V (A) 1600 1850 2000 3500 3500 5600 5600 7300 6600
Ue = 500V (A) 1600 1850 2000 3500 3500 5600 5600 7000 6600
Ue = 690V (A) 1000 1200 1660 2200 2200 5000 5000 6700 6000
Ue = 1000V (A) 350 350 850 1100 1100 3000 3000 3500 3500
Short-time current 1 sec. (A) 2500 2500 4000 5500 5500 7500 7500 9700 11600
5 sec. (A) 2500 2500 3200 3500 3500 5200 5200 7700 8800
10 sec. (A) 2300 2300 2400 2500 2500 4000 4000 6100 7350
30 sec. (A) 1250 1250 1400 1600 1600 2800 2800 4400 5300
1 min. (A) 900 900 1000 1200 1200 1800 1800 3500 4500
3 min. (A) 600 600 750 900 900 1200 1200 2300 2800
Short-time current min. 10 10 10 10 10 10 10 10 10
Protec. against short-circuit with fuses
without TOR
Coord. type “1” gL/gG (A) 355 355 500 500 630 1250 1250 1250 2x800
Coord. type "2" gL/gG (A) 250 250 315 400 500 630 800 1000 1250
Without welding gL/gG (A) 200 200 250 315 425 500 630 800 1000
Impedance per pole (mΩ) 0.30 0.30 0.28 0.28 0.28 0.15 0.13 0.14 0.11 A
Power dissipation AC-1 (W) 19 19 27.7 27.7 56.7 54.3 63.7 140 171.8
per pole AC-3 (W) 6.8 10.3 11.7 17.5 26.7 26.5 45.3 68.6 74.8
Insulation resistance
Between adjacent poles
Between poles and earth
(mΩ)
(mΩ)
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
B
Between input and output (mΩ) > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10

C
CK07B CK08B CK09B CK95B CK10C CK11C CK12B CK13B

Four pole contactors


Rated thermal current Ith at θ ≤ 40ºC (A) 200 325 400 500 600 700 1000 1250 D
Rated operational voltage Ue (V) 690 1000 1000 1000 1000 1000 1000 1000
Rated insulation voltage Ui (V) 1000 1000 1000 1000 1000 1000 1000 1000
Maximum continuous current AC-1 (A) 200 325 400 500 600 700 1000 1250
Frequency limits
Making capacity (RMS) (IEC 947)
(Hz)
(A)
25...400
1150
25...4000
1850
25...400
2500
25...400
3700
25...400
6500
25...400
6500
25...400
6700
25...400
8250
E
Breaking capacity (RMS) (IEC 947)
Ue ≤ 400V (A) 950 1600 3500 3500 5600 5600 6700 6600
Ue = 500V
Ue = 690V
(A)
(A)
950
800
1600
1000
3500
2200
3500
2200
5600
3500
5600
3500
6700
6000
6600
6000
F
Ue = 1000V (A) – 350 1100 1100 2000 2000 3500 3500
Short-time current 1 sec. (A) 2100 2500 5500 5500 7500 7500 9700 11600
5 sec. (A) 1500 2500 3500 3500 5200 5200 7700 8800
10 sec. (A) 1150 2300 2500 2500 4000 4000 6100 7350
G
30 sec. (A) 750 1250 1600 1600 2800 2800 4400 5300
1 min. (A) 550 900 1200 1200 1800 1800 3500 4500
3 min. (A) 350 600 900 900 1200 1200 2300 2800
Recovery time min. 10 10 10 10 10 10 10 10 H
Short-circuit protection with fuse
without TOR
Coord. type "1" gL/gG (A) 315 500 500 630 1250 1250 1250 2x800
Coord. type “2” gL/gG (A) 250 400 400 500 630 800 1000 1250 I
Without welding gL/gG (A) 200 315 315 425 500 630 800 1000
Impedance per pole (mΩ) 0.45 0.32 0.28 0.28 0.15 0.13 0.14 0.11
Power dissipation per pole
AC-1 (W) 18 33.8 44.8 56.7 61.2 68.6 140 171.8 X
Insulation resistance
Between adjacent poles (mΩ) > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10
Between poles and earth (mΩ) > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10
Between input and output (mΩ) > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10

C.43
Series CK
Electrical endurance

Mixed category AC4 / AC3


Electrical endurance for mixed category
(AC-3/AC-4) is calculated with the following Electrical endurance Electrical endurance (AC-3)
formula: (AC-3/AC-4) = % oper AC-4
1 +
100
X ( Elec.endur. (AC-3)
Elec.endur.(AC-4)
-1 )

Category AC1
Contactors

Number of
operations

B
Ic=Ie
for all voltages

D Category AC2

E Number of
operations

X
.

Rated motor
power
(Ic = 2.5 Ie)

C.44
Series CK
Electrical endurance (continued)

Category AC3

Number of
operations

3P and 4P contactors
A
.

Rated
motor
power
(Ic = Ie) B

Category AC4 D

Number of E
operations

I
.

Rated X
motor
power
(Ic = 6 Ie)

C.45
Series CK
Three pole contactors. Control circuit
Alternating current
CK75CA CK08CA CK85BA CK09BE CK95BE CK10CE CK11CE CK12BE CK13BA
CK85BE

Rated insulation voltage Ui (V) 1000 1000 1000 1000 1000 1000 1000 1000 1000
Standard voltages Us (50/60 Hz) (V) 24...690 24...690 24...690 24...690 24...690 24...690 24...690 24...690 24...440
Operating limits
Switch-on xUs 0.8...1.1 0.8...1,1 0.8...1.1 0.8...1,1 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1
Switch-off xUs 0.4...0.6 0.4...0,6 0.4...0.6 0.4...0.6 0.4...0.6 0.4...0.6 0.4...0.6 0.4...0.6 0.25...0.55
Consumption. Monofrequency coils
Magnetic circuit CK....A (VA) 42 42 46 - - - - - 6
closed CK....E (VA) - - 20 20 20 23 23 25 -
Magnetic circuit CK....A (VA) 500 500 830 - - - - - 2760
open CK....E (VA) - - 425 425 425 680 680 750 -
Power CK....A (W) 21 21 17 - - - - - 5
Contactors

dissipation CK....E (W) - - 3.5 3.5 3.5 4 4 4.5 -


Consumption. Bifrequency coils
Magnetic circuit 50Hz (VA) 46 46 60 - - - - - -
closed (CK....A) 60Hz (VA) 38.3 38.3 50 - - - - - -
Magnetic circuit 50Hz (VA) 568 568 1082 - - - - - -
open (CK....A) 60Hz (VA) 473 473 901 - - - - - -
Power 50Hz (W) 23 23 22.2 - - - - - -
dissipation (CK....A) 60Hz (W) 19.1 19.1 18.5 - - - - - -
Power factor
Magnetic circuit CK....A (cos ϕ) 0.4 0.4 0.37 - - - - - approx. 1
(cos ϕ)
A closed
Magnetic circuit
CK....E
CK....A (cos ϕ)
-
0.6
-
0.6
-
0.6
-
-
-
-
-
-
-
-
-
-
-
approx. 1
open CK....E (cos ϕ) - - - - - - - - -
Opening and closing times at Us
Making time (ms) 20...25 20...25 36...40 60...70 60...70 80...90 80...90 70...80 50...55
B at excitation (NO)
Breaking time (ms) 10...13 10...13 10...15 13...17 13...17 40...50 40...50 70...80 115...130
at de-energisation (NO)
Mechanical endurance 106 ops 10 10 10 10 10 10 10 10 3
C Maximum rate
No load ops./h 2400 2400 2400 1200 1200 900 900 900 600
AC-1/AC-3 at rated power. ops./h 600 600 600 600 600 300 300 300 120
AC-2 at rated power ops./h 250 250 250 250 250 200 200 200 120
D AC-4 at rated power ops./h 150 150 150 150 150 120 120 120 120

E
Direct current
F CK75CE CK08CE CK85BE CK09BE CK95BE CK10CE CK11CE CK12BE

Rated insulation voltage Ui (V) 1000 1000 1000 1000 1000 1000 1000 1000
Standard voltages Us (50/60 Hz) (V) 24...500 24...500 24...500 24...500 24...500 24...500 24...500 24...500
G Operating limits
Switch-on xUs 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1,1 0.8...1.1
Switch-off xUs 0.4...0.6 0.4...0.6 0.35...0.5 0.4...0.6 0.4...0.6 0.4...0.6 0.4...0,6 0.4...0.6
Consumption

H Magnetic circuit closed


Magnetic circuit open
(W)
(W)
2
135
2
135
3.5
350
3.5
350
3.5
350
4
405
4
405
4.5
650
Opening and closing times at Us
Making time (ms) 60...70 60...70 60...70 60...70 60...70 80...90 80...90 70...80
at excitation (NO contacts)
I Breaking time (ms) 13...17 13...17 13...17 13...17 13...17 40...50 40...50 40...50
at de-energisation (NO contacts)
Mechanical endurance 106 ops. 10 10 10 10 10 10 10 10
Maximum rate
X No load ops./h 1200 1200 1200 1200 1200 900 900 900
AC-3 at rated power ops./h 600 600 600 600 600 300 300 300
AC-4 at rated power ops./h 150 150 150 150 150 120 120 120

C.46
Series CK
Four pole contactors. Control circuit
Alternating current
CK07BA CK08BA CK09BE CK95BE CK10CE CK11CE CK12BE CK13BA
CK07BE CK08BE

Rated insulation voltage Ui (V) 1000 1000 1000 1000 1000 1000 1000 1000
Standard voltages Us (50/60 Hz) (V) 24...690 24...690 24...690 24...690 24...690 24...690 24...690 110...440
Operating limits
Switch-on xUs 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1

3P and 4P contactors
Switch-off xUs 0.4...0.6 0.4...0.6 0.4...0.6 0.4...0.6 0.4...0.6 0.4...0.6 0.4...0.6 0.25...0.55
Consumption. Monofrequency coils
Magnetic circuit CK....A (VA) 46 130 - - - - - 6
closed CK....E (VA) 20 25 25 25 23 23 25 -
Magnetic circuit CK....A (VA) 830 2860 - - - - - 2760
open CK....E (VA) 425 750 750 750 680 680 750 -
Power CK....A (W) 17 53 - - - - - 5
dissipation CK....E (W) 3.5 4.5 4.5 4.5 4 4 4.5 -
Consumption. Bifrequency coils
Magnetic circuit 50Hz (VA) 60 159.3 - - - - - -
closed (CK....A) 60Hz (VA) 50 132.7 - - - - - -
Magnetic circuit 50Hz (VA) 1082 3509 - - - - - -
open (CK....A) 60Hz (VA) 901 2924 - - - - - -
Power 50Hz (W) 22.2 65.3 - - - - - -
dissipation (CK....A) 60Hz (W) 18.5 54.4 - - - - - -
Power factor
Magnetic circuit CK....A (cos ϕ) 0.37 0.37 - - - - - approx. 1
(cos ϕ)
closed
Magnetic circuit
CK....E
CK....A (cos ϕ)
-
0.6
-
0.6
-
-
-
-
-
-
-
-
-
-
-
approx. 1
A
open CK....E (cos ϕ) - - - - - - - -
Opening and closing times at Us
Making time (ms) 36...40 60...70 70...80 70...80 110...115 80...90 110...115 50...55
at excitation (NO) B
Breaking time (ms) 10...15 13...17 70...80 70...80 70...80 40...50 70...80 70...80
at de-energisation (NO)
Mechanical endurance 106 ops. 10 10 10 10 10 10 10 3
Maximum rate C
No load ops./h 2400 900 900 900 900 900 900 600
AC-1/AC-3 at rated power ops./h 600 600 600 600 300 300 300 120

Direct current F
CK07BE CK08BE CK08BE CK95BE CK10CE CK11CE CK12BE

Rated insulation voltage Ui (V) 1000 1000 1000 1000 1000 1000 1000
Standard voltages Us
Operating limits
(V) 24...500 24...500 24...500 24...500 24...500 24...500 24...500
G
Switch-on xUs 0.75...1.1 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1
Switch-off xUs 0.4...0.6 0.4...0.6 0.4...0.6 0.4...0.6 0.4...0.6 0.4...0.6 0.4...0.6
Consumption.
Magnetic circuit closed (W) 3.5 4.5 4.5 4.5 4.5 4.5 4.5
H
Magnetic circuit open (W) 350 650 650 650 650 650 650
Opening and closing times at Us
Making time (ms) 60...70 70...80 70...80 70...80 80...90 80...90 110...115
at excitation (NO contacts) I
Breaking time (ms) 13...17 70...80 70...80 70...80 40...50 40...50 70...80
at de-energisation (NO contacts)
Mechanical endurance 106 ops 10 10 10 10 10 10 10
Maximum rate X
No load ops./h 1200 900 900 900 900 900 900
AC-3 at rated power ops./h 600 600 600 600 600 300 300

C.47
Series CK
Contact sequence
Basic contactor Auxiliary contact blocks
Lateral mounted

BCLL 20 BCLL 11
BRLL 20 BRLL 11

Three-pole CK75C... 0 7.3 10.4 0 3.5 10.4 0 3.5 10.4


contactors CK08C...
3 NO 1,8
CK85B... 0 10.4 14 0 3.5 14 0 3.5 14
CK09B...
CK95B...
1,8
CK10C... 0 12 17 0 3.5 17 0 3.5 17
CK11C...
1.8
Contactors

CK12B... 0 12.6 17.5 0 3.5 17.5 0 3.5 17.5


CK13B...

1.8
CK07B... 0 7.7 10.7 0 3.5 10.7 0 3.5 10.7

1.8
CK08B... 0 10.4 14 0 3.5 14 0 3.5 14
CK09B...
CK95B...
A 0 12 17 0 3.5 17 0
1.8
3.5 17
CK10C...
CK11C...
1.8
B CK12B... 0 12.6 17.5 0 3.5 17.5 0 3.5 17.5
CK13B...
1.8
C
Numbering of the terminals
D
Three pole contactors Four pole contactors
CK75C_ _3_ ... CK13B _ _3_ CK07B_ _4_ ... CK13B _ _4_
E

G Auxiliary contact blocks. Lateral mounting Voltage suppressor block


BCLL20 BCLL11 K/RC...

I
BRLL20 BRLL11
Mechanical interlock
X BEKV, BEKVA1, BEKVS1, BEKVH

C.48

32764_C22_C59_E.indd 48 11-07-2005 16:17:21


Series CK
Notes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3P and 4P contactors
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

C.49
Series M
Dimensional drawings
Three and four pole minicontactors Auxiliary contact block. Lateral mounting
Screw terminal Screw terminal
MC_C_ _ _ AT◆ 0.210 kg
MC_I _ _ _ ATD 0.225 kg MACN2 _ _AT - MARN2 _ _AT 0.025 kg
MC_A_ _ _ AT◆ 0.170 kg MC_K_ _ _ ATD 0.225 kg MACN4 _ _AT - MARN4 _ _AT 0.040 kg

.
. . .
Contactors

Ring terminal Ring terminal


MC_A_ _ _ AR◆ 0.170 kg MC_C_ _ _ AR◆ 0.210 kg
MACN2 _ _AR - MARN2 _ _AR 0.025 kg
MACN4 _ _AR - MARN4 _ _AR 0.040 kg

A . . .

B
Terminal: faston 2x2,8 insulated Terminal: faston 2x2.8 insulated

C MC_A_ _ _ AF◆ 0.165 kg MC_C_ _ _ AF◆ 0.210 kg MACF4 _ _AF 0.035 kg


MARF4 _ _AF 0.035 kg

.
D
.

E . . .

F
Terminal: printed circuit

MC_A_ _ _ A I◆ 0.165 kg MC_C_ _ _ A I◆ 0.210 kg


G .
.
.
.
. .

H
.

I . . . .

.
.

C.50
Series M

Auxiliary contact blocks. Lateral mounting Electronic timer block


Screw terminal MREBC _0AC2 0.040 kg

MACL_ _ _AT 0.013 kg


MARL_ _ _ATS 0.013 kg

3P and 4P minicontactors
. .

.
.

(1) AC-control. (1) Frontal mounting


(2) DC-control. (2) Lateral mounting

Voltage suppressor block


Ring terminal
MACL_ _ _AR 0.013 kg MP0A_AE_ 0.010 kg
MARL_ _ _ARS 0.013 kg MP0C_AE3 0.010 kg

.
.

.
A
(1) AC-control.
(2) DC-control.
B
Terminal: faston 2x2.8 insulated
MACL _ _AF
MARL _ _AFS
0.009 kg
0.009 kg
C
.

D
.

(1) AC-control.
E
(2) DC-control.

Terminal: printed circuit


F
MACL _ _AI 0.009 kg
MARL _ _AIS 0.009 kg
G
. .

H
.

(1) AC-control.
(2) DC-control.
I

C.51
Series CL
Dimensional drawings. Three pole contactors
Alternating current
CL00A3...., CL01A3...., CL02A3.... CL25A3....
0.280 kg 0.280 kg 0.280 kg 0.270 kg

. .

.
. .
Types Types
Terminal : ring terminal Terminal : ring terminal
Contactors

CL03A3...., CL04A3.... CL45A3....


0.490 kg 0.500 kg 0.520 kg

. . . .
.

.
A
Types Types
Terminal : ring terminal Terminal : ring terminal
B
CL06A3...., CL07A3...., CL08A3.... CL09A3...., CL10A3....
C 1.105 kg 1.120 kg 1.130 kg 1.450 kg 1.470 kg

D
.

. .

E Types
Types Dimension in function Dimension in function
Terminal : ring terminal of the thickness Terminal : ring terminal of the thickness
(ring terminal) (ring terminal)

C.52
Series CL
Three pole contactors
Direct current
CL00D3...., CL01D3...., CL02D3.... CL25D3....
0.490 kg 0.490 kg 0.490 kg 0.480 kg

. .

3P and 4P contactors
.

.
. .
Types Types
Terminal : ring terminal Terminal : ring terminal

CL03D3...., CL04D3.... CL45D3....


0.480 kg 0.835 kg 0.825 kg

. . . .

A
.

.
Types Types
Terminal : ring terminal Terminal : ring terminal B

CL06D3...., CL07D3...., CL08D3....


C
CL09D3...., CL10D3....
1.110 kg 1.110 kg 1.110 kg 1.440 kg 1.440 kg

.
D
tion of the thickness
Dimension in func-

. .
E
function of the
(ring terminal)

thickness (ring
Dimension in

Types Types
Terminal : ring terminal Terminal : ring terminal F

Coil with electronic module G


CL06E3...., CL07E3...., CL08E3.... CL09E3...., CL10E3....
1.095 kg 1.110 kg 1.120 kg 1.440 kg 1.460 kg
H

I
.

. .

C.53
Series CL
Dimensional drawings. Four pole contactors
Alternating current
CL01A4...., CL02A4...., CL01AB...., CL02AB.... CL03A4...., CL04A4...., CL03AB...., CL04AB....
0.280 kg 0.280 kg 0.280 kg 0.280 kg 0.490 kg 0.500 kg 0.490 kg 0.500 kg

. . .

.
.
Types Types
Terminal : ring terminal
Terminal : ring terminal
Contactors

CL05A4...., CL07A4...., CL05AB...., CL07AB...., CL08AB... CL09A4....


1.240 kg 1.270 kg 1.240 kg 1.270 kg 1.270 kg 1.450 kg
.

A
.

Types Dimension in function Types Dimension in function


B Terminal : ring terminal of the thickness Terminal : ring terminal of the thickness
(ring terminal) (ring terminal)

C Direct current
CL01D4...., CL02D4...., CL01DB...., CL02DB.... CL03D4...., CL04D4...., CL03DB...., CL04DB....

D 0.490 kg 0.490 kg 0.490 kg 0.490 kg 0.825 kg 0.835 kg 0.825 kg 0.835 kg

. . .

E
.

F .
Types Types
Terminal : ring terminal Terminal : ring terminal

G
CL05D4...., CL07D4...., CL05DB...., CL07DB...., CL08DB... CL09D4....
1.290 kg 1.290 kg 1.290 kg 1.290 kg
H
the thickness (ring terminal)

.
Dimension in function of the

.
Dimension in function of

. .
thickness (ring terminal)

. .
I

X Types Types
Terminal : ring terminal
Terminal : ring terminal

C.54
Series CL
Four pole contactors
Coil with electronic module
CL05E4...., CL07E4...., CL05EB...., CL07EB...., CL08EB... CL09E4....
1.290 kg 1.290 kg 1.290 kg 1.320 kg 1.320 kg 1.500 kg

3P and 4P contactors
.
.

C.55
Series CL
Dimensional drawings
Auxiliary contact blocks Accessories
Screw terminal Voltage suppressor block

BCLF... 0.015 kg BSLR, BSLDZ, BSLV 0.020 kg

.
.

CL00 ... CL25


Contactors

BCLL..., BRLL.... 0.048 kg

CL03 ... CL45


A

B
BTLF... 0.085 kg

.
C
CL05 ... CL10

D
Mechanical latch block
E RMLF 0.082 kg

Ring terminal

F BCRF... 0.015 kg

G
.

H
Mechanical / mechanical-electrical interlock
I BEL, BELA, BEL02, BELA02 0.025 kg
BTRF... 0.085 kg

.
X

C.56
Series CL

Electronic timer block Interface modules


BETL02, BETL45 0.040 kg IMR..., IMRF..., IMSSD, IMAMS 0.020 kg

3P and 4P contactors
CL00 ... CL25 CL00 ... CL25

CL03 ... CL45 CL03 ... CL45

C
CL05 ... CL10 CL05 ... CL10

C.57
Series CK
Dimensional drawings
Three pole contactors
CK75C 3.500 kg
.
CK08C 3.500 kg .
.

.
.
.
Contactors

CK85B 6.100 kg
CK09B 6.200 kg
CK95B 6.300 kg

11.00 kg
B CK10C
CK11C 11.00 kg

E 18.00 kg
CK12B

CK13B 35.00 kg
I

C.58
Series CK

Four pole contactors Mechanical interlock


.
CK07B 4.700 kg BEKH 0.350 kg

A
CK75C3... - CK08C3... 55
CK85B3... - CK95B3... 55

3P and 4P contactors
CK10C3... - CK11C3... 33
CK12B3... 75

CK08B 14.90 kg
CK09B 15.10 kg
CK95B 15.30 kg

A A
BEKVA1 550 0.900 kg
BEKVS1 350 0.800 kg
CK10C 22.30 kg
CK11C 22.80 kg B

CK12B 23.30 kg E

BEKV 1.200 kg
G

CK13B 44.00 kg
I

. .

C.59
Series MTO
Thermal overload relays
for minicontactors from
0.11 to 14A
• Control circuit up to 690V
• Power circuit up to 690V
• Three-pole differential (phase unbalance protection)
Thermal overload relays

• Automatic ambient temperature compensation between


– 25ºC and + 60ºC
• Choice of manual or automatic reset
• Direct connection to contactor or independent mounting using accessories.
• Screw and Ring terminal versions
• Terminals protected against accidental contact in accordance with
VDE 0106 T.100 and VBG4.
• Terminal numbering in accordance with EN 50005
• Degree of protection IP20 (EN 60529)
• Additional auxiliary contact block 1NO (with manual reset only)

A Standards General characteristics


IEC/EN 60947-4-1 CSA 22.2/14 • Thermal protection against balanced overload.
IEC/EN 60947-5-1 NI C 63-650 • Three-pole differential (phase unbalance protection).
B UNE 115 VDE 0660 • Automatic ambient temperature compensation.
NFC 63-650 UL 508 • Front mounted selector for choosing utilisation current.
• Reset button, 2 positions :
Manual(H) and Automatic(A) by turning the blue selector.
C • Stop push button, independent of reset (red).
• Manual trip lever (tripping test).
• Tripping indicator (0-1).
D Approvals • To facilitate wiring arrangements terminal 96 fits directly onto coil terminal
(A2) and terminal 14/22 fits directly onto the feedback auxiliary contact.

E
cULus NEMKO

G SEMKO SETI

Order codes ! pg. C.61


Technical data ! pg. C.66
Dimensions ! pg. C.67

C.60
Series MTO
Thermal overload relays for minicontactors
For use with: Setting range Fuse Terminal: Terminal: Pack
(regulation) screw ring terminal
aM gL
Type 2 Type 1 Type 2 Type 1 Cat. no. Ref. no. Cat. no. Ref. no.
min. max.
A A A A A A
MC0... 0.11 0.17 0.5 0.5 0.5 0.5 MT03A 101000 MT03RA 103540 10
MC1... 0.17 0.26 0.85 1 1 1 MT03B 101001 MT03RB 103541 10
MC2... 0.26 0.43 1 2 2 4 MT03C 101002 MT03RC 103542 10
0.43 0.65 1 4 2 8 MT03D 101003 MT03RD 103543 10
0.65 1 2 6 4 12 MT03E 101004 MT03RE 103544 10
0.85 1,3 2 6 4 12 MT03F 101005 MT03RF 103545 10
1.1 1.6 2 10 4 16 MT03G 101006 MT03RG 103546 10
1.35 2 4 10 6 16 MT03H 101007 MT03RH 103547 10
1.7 2.4 4 16 6 25 MT03I 101008 MT03RI 103548 10
2.2 3.2 4 20 6 32 MT03J 101009 MT03RJ 103549 10
2.5 4 4 20 6 32 MT03R 101015 10
3 4.7 6 20 10 32 MT03K 101010 MT03RK 103550 10
4 6.3 10 32 16 50 MT03L 101011 MT03RL 103551 10

Order codes
5.5 8 12 50 20 63 MT03M 101012 MT03RM 103552 10
7.5 10.5 16 50 25 80 MT03N 101013 MT03RN 103553 10
10 14 20 32 32 100 MT03P 101014 MT03RP 103554 10

Accessories A
Terminal Cat. no. Ref. no. Pack

Input Screw MVE0T 101020 5


terminals Ring terminal MVE0R 103562 5
B

For separate mounting onto standard EN 50022-35 profile MVB0T 101021 5


C
Base

E
Auxiliary contact Frontal fixing to the relay Screw MATV10AT 101022 10
block With trip indicator (0-I) Ring terminal MATV10AR 103563 10
One block per relay and only for manual reset
F

G
Identification Sheets of labels (sheets of 260 labels each) EAT 260 100548 1
Labeling plate base (50 pieces in one pack) SPR 100549 1

C.61
Series RT
Thermal overload relays
for contactors from
0.16 to 850A
• Control circuit up to 690V AC
• Power circuit:
- RT1, RT12: up to 690V
Thermal overload relays

- RT2, RT22, RT3, RT32, RT4/4L, RT5/5L & RT6/6L: up to 1000V


• Thermal protection against normal overloads.
• Three pole differential (phase unbalance protection).
• Protection against long starting times.
• Automatic ambient temperature compensation between
– 25ºC y + 60ºC.
• Front mounted test button.
• Trip indication.
• Independent auxiliary contacts with double rupture
(1NO + 1NC).
• Function selector:
- Manual RESET
- Manual RESET and STOP
- Automatic RESET with STOP
- Automatic RESET without STOP

A Standards
IEC/EN 60947-4-1 CSA 22.2/14
IEC/EN 60947-5-1 NI C 63-650
B UNE 115 VDE 0660
NFC 63-650 UL 508 Manual RESET
CEI 17-50

C Manual RESET
and STOP

D Approvals Automatic RESET


without STOP

E Automatic RESET
cULus with STOP

G Lloyd’s Bureau RINA


Register Veritas

Order codes ! pg. C.63


Technical data ! pg. C.68
Dimensions ! pg. C.72

C.62
Series RT
Thermal overload relays for contactors
For use Setting range Fuses (1) Srew Ring Pack
with: (regulation) terminal terminal
aM gL - gG

Cat. no. Ref. no. Cat. no. Ref. no.


min. max.
A A A A
Class 10A CL00 0.16 0.26 2 2 RT1B 113700 RT1RB 114087 5
CL01 0.25 0.41 2 2 RT1C 113701 RT1RC 114088 5
CL02 0.4 0.65 2 2 RT1D 113702 RT1RD 114089 5
CL25 0.65 1.1 2 4 RT1F 113703 RT1RF 114090 5
CL03 1.0 1.5 4 6 RT1G 113704 RT1RG 114091 5
CL04 1.3 1.9 4 6 RT1H 113705 RT1RH 114092 5
CL45 1.8 2.7 6 10 RT1J 113706 RT1RJ 114093 5
2.5 4.0 8 16 RT1K 113707 RT1RK 114094 5
4.0 6.3 12 20 RT1L 113708 RT1RL 114095 5
5.5 8.5 16 20 RT1M 113709 RT1RM 114096 5
8.0 12.0 20 25 RT1N 113710 RT1RN 114097 5
10.0 16.0 25 35 RT1P 113711 RT1RP 114098 5

Order codes
14.5 18.0 32 50 RT1S 113712 RT1RS 114099 5
17.5 22.0 40 50 RT1T 113713 RT1RT 114100 5
21.0 26.0 40 63 RT1U 113714 RT1RU 114101 5
25.0 32.0 50 80 RT1V 113715 RT1RV 114102 5
30.0 40.0 63 100 RT1W 113716 RT1RW 114103 5

Class 10 CL05 11.5 15.0 32 35 RT2A 113717 RT2RA 114104 1


CL06 14.5 19.0 40 50 RT2B 113718 RT2RB 114105 1
CL07 18.5 25.0 50 63 RT2C 113719 RT2RC 114106 1
24.0 32.0 63 100 RT2D 113720 RT2RD 114107 1
CL08
30.0 43.0 80 125 RT2E 113721 RT2RE 114108 1
CL09 42.0 55.0 100 160 RT2G 113722 RT2RG 114109 1
CL10 54.0
64.0
65.0
82.0
125
125
160
200
RT2H
RT2J
113723 RT2RH
113724 RT2RJ
114110
114111
1
1
A
78.0 97.0 125 200 RT2L 113725 RT2RL 114112 1
90.0 110 160 250 RT2M 113726 RT2RM 114113 1

0.4 0.65 2 2 RT12D 139138 RT12RD 114060 5


B
Class 20 CL00
CL01 0.65 1.1 2 4 RT12F 139139 RT12RF 114061 5
CL02 1 1.5 4 6 RT12G 139140 RT12RG 114062 5
1.3 1.9 4 6 RT12H 139141 RT12RH 114063 5
CL25
CL03
1.8
2.5
2.7
4.1
8
8
10
16
RT12J
RT12K
139142
113640
RT12RJ
RT12RK
114159
114114
5
5
C
CL04 4 6.3 12 20 RT12L 113641 RT12RL 114115 5
CL45 5.5 8.5 16 20 RT12M 113642 RT12RM 114116 5
8 12 20 35 RT12N 113643 RT12RN 114117 5
10
14.5
16
18
25
32
35
50
RT12P
RT12S
113644
113645
RT12RP
RT12RS
114118
114119
5
5
D
17.5 22 40 50 RT12T 113646 RT12RT 114120 5
21 26 40 63 RT12U 113647 RT12RU 114121 5
25 32 50 80 RT12V 113648 RT12RV 114122 5
30 40 63 100 RT12W 113649 RT12RW 114123 5 E
CL05 24 32 63 80 RT22D 113650 RT22RD 114124 1
CL06 30 43 80 100 RT22E 113651 RT22RE 114125 1
42 55 100 160 RT22G 113652 RT22RG 114126 1
CL07
CL08
54
64
65
82
125
125
160
200
RT22H
RT22J
113653
113654
RT22RH
RT22RJ
114127
114128
1
1
F
CL09 78 97 125 200 RT22L 113655 RT22RL 114129 1
CL10 90 110 160 250 RT22M 113656 RT22RM 114130 1

G
(1) Most suitable fuse in accordance with IEC 60947-4-1.

C.63
Series RT
Thermal overload relays for contactors
For use Setting range Fuses (1) Cat.no. Ref. no. Pack
with: (regulation) (Screw terminal)
aM gL - gG

min. max.
A A A A
Class 10 CK75 55 80 125 200 RT3B 113727 1
CK08 63 90 125 200 RT3C 113728 1
Thermal overload relays

Direct mounting 90 120 160 250 RT3D 113729 1


110 140 200 315 RT3E 113730 1
140 190 250 355 RT3F 113731 1

CK85 120 190 250 315 RT4N 113732 1


CK09 175 280 315 400 RT4P 113733 1
CK95 (2) 200 310 400 500 RT4R 113734 1

CK10 120 190 250 315 RT5A 113750 1


CK11 175 280 315 400 RT5B 113751 1
CK12 (3) 250 400 500 630 RT5C 113752 1
315 500 630 800 RT5D 113753 1
430 700 800 1000 RT5E 113754 1

CK13 (4) 500 850 100 1250 RT6A 113760 1

Class 20 CK75 63 90 125 200 RT32C 113657 1


CK08 90 120 160 250 RT32D 113658 1
Direct mounting 110 140 200 315 RT32E 113659 1
140 190 250 355 RT32F 113660 1

A Class 30 CL...
CK...
2.5
4
4
6.5
10
12
16
20
RT4LA
RT4LB
113735
113736
1
1
Mounting with 5.5 8.5 16 25 RT4LC 113737 1
screws 7.5 11 20 32 RT4LD 113738 1
10 16 25 40 RT4LE 113739 1
B 12.5
17
20
27
32
50
50
80
RT4LF
RT4LG
113740
113741
1
1
26 40 80 125 RT4LH 113742 1
32 52 100 160 RT4LJ 113743 1
45 70 125 160 RT4LK 113744 1
C 60
80
90
125
160
200
200
250
RT4LL
RT4LM
113745
113746
1
1
CK85 120 190 250 315 RT4LN 113747 1
CK09 175 280 315 400 RT4LP 113748 1
CK95 (2) 200 310 400 500 RT4LR 113749 1
D CK10 120 190 250 315 RT5LA 113755 1
CK11 175 280 315 400 RT5LB 113756 1
CK12 (3) 250 400 500 630 RT5LC 113757 1
315 500 630 800 RT5LD 113758 1
E 430 700 800 1000 RT5LE 113759 1

CK13 (4) 500 850 1000 1250 RT6LA 113761 1

F (1) Most suitable fuse in accordance with IEC 60947-4-1.


(2) Fitting direct to the contactor.
(3) Fitting direct to the contactor: by means of a coupling and connection set.
Separate mounting:with screws on DIN rail / with cable connection.
G (4) RT6A = RT1 with right setting range plus RTXP, independent mounting base adaptor, to be utilisied with current
transformer connected by passing cable chosen by customer. Current transformer data on request.

C.64
Series RT
Accessories
Cat. no. Ref. no. Pack

Base DIN EN50022-35


for separate RT1 RTXP 105170 1
mounting RT2 RT2XP 113764 1

Setting range RT... RTX3 113762 1


cover protection

Order codes
Push-button for distance RESET
with flexible cable RT1... - RT6.... (front) 0.5 meters RTXS 113855 1
RT1... - RT6.... (front) 1 meters RTXSL 113856 1
RT1..., RT2..., RT4..., RT5..., RT6... (back) RTXBS 108864 1

Terminal
protection
for RT3 or CK75C/CK08C
Thermal overload relay 1 pole IPxxB PTPCK75 103747 1
A
Connection contactor-relay 3 poles RT3PXX3P 110565 1

B
Remote electrical RT1... - RT6... RTXRR ◆ 1
reset
C

Available coil voltages (V)


E
© B D G J N U X
AC/DC 12 24 48 110 220 380 440
240 415 480
F

C.65
Series MTO
Technical data
General Mounting positions
• Thermal protection against balanced overload.
• Three-pole differential ( phase unbalance protection).
• Automatic ambient temperature compensation.
• Front mounted selector for choosing utilisation current.
Thermal overload relays

• Reset button, 2 positions :


Manual(H) and Automatic(A) by turning the blue selector.
• Stop push button, independent of reset (red).
• Manual trip lever (tripping test).
• Tripping indicator (0-1).
• To facilitate wiring arragements terminal 96 fits directly
onto coil terminal (A2) and terminal 14/22 fits directly
onto the feedback auxiliary contact.
Main circuit (poles)
MT0...
Rated insulation voltage (Ui) (V) 750
Conformity to standards according to IEC 947
IEC 60947-4 CEI 17-50 VDE660 Frequency (Hz) 0...400
UNE 115 NI C63-650 UL508 Power dissipation per pole (W) min. 1 / max. 2.5
NFC63-650 Terminal capacity
Screw M 3.5 (pozidrive head)
safety flange
Maximum capacity :
Approvals Solid (Ø mm) 2 x 2 wires
A UL CSA SEMKO Stranded without end sleeve (mm2)
Stranded with end sleeve
2 wires Ø 2.5
SETI NEMKO
pen (2 end sleeves) (mm2) 2 wires Ø 0.75
pen (1 end sleeve) (mm2) 2 wires Ø 1
B Ambient conditions Tightening torque (Nm)
1 wires Ø 2.5
0.8
Storage temperature -55ºC to +80ºC
Operation temperature -25ºC to +60ºC
Altitude up to 3000m Nominal values
C from 3000 to 4000m 90%Ie 80%Ue Control circuit (incorporated auxiliary contact)
from 4000 to 5000m 80%Ie 75%Ue MT0...
Degree of protection IP20
Protection treatment Tropical finish Rated insulation voltage (Ui) (V) 750
D according to IEC 947
Rated thermal current (Ith) θ ≤ 60ºC (A) 10
Tripping currents
Climatic resistance AC-15 Ue-Ie (V-A) 223-3, 380-2, 500-1
E Continuous tests 40 / 125 / 56 DC-13
Short-circuit protection
Ue-Ie (V-A)
(A)
60-0.5, 110-0.2, 220-0.1
6
Cold (72h)
Temperature -40ºC (max.glass gL fuse - w/h welding)
Dry heat (96h) Number and type of contacts
F Temperature
Relative humidity
+125ºC
< 50%
Humid heat (56 days)
Temperature +40ºC
G Cyclical tests
Relative humidity 95%

First half-cycle (12h)


Low temperature +25ºC Control circuit (auxiliary contact block)
Relative humidity 93%
H Second half-cycle (12h)
MATV10AT
Low temperature +55ºC Rated insulation voltage (Ui) (V) 750
Relative humidity 95% according to IEC 947
Number of consecutive cycles 6 Rated thermal current (Ith) θ ≤ 60ºC (A) 10
I Tripping currents
AC-15 Ue-Ie (V-A) 223-1, 380-0.5
DC-13 Ue-Ie (V-A) 60-0.1, 110-0.5
Short-circuit protection (A) 6
X (max.glass gL fuse - w/h welding)
Number and type of contacts

C.66
Series MTO
Dimensional drawings
Numbering of the terminals Thermal overload relay
MT0...

. .

Technical data
Tripping curves 0.091 kg

Trip Time (s)


Thermal overload relay
+ aux. contact block (front mounting)

A
Single phase
Cold state

Three phase
Cold state C
Independent mounting
of the thermal overload relay
D
Three phase
. Warm state

.
E
.

.
Multiples of setting current
.

F
.

.
. G

C.67
Series RT
Technical data
RT1... RT2... RT3... RT4.../ 4L... RT5.../ 5L... RT6.../ 6L...

General
Class 10A / 20 10 / 20 10 / 20 10 / 30 10 / 30 10 / 30
Setting range (A) 0.16 ... 40 11.5 ... 110 55 ... 190 2.5 ... 310 120 ... 700 500 ... 850
Suitable for CL00...CL45 CL05...CL10 CK75...CK08 CL,CK CK10...CK12 CK13
Thermal overload relays

Main circuit
Rated insulation voltage (V) 690 1000 1000 1000 1000 1000
(IEC947-4) Ui
Frequency limits (Hz) 0...400 0...400 0...400 50...60 50...60 50...60
Terminal capacity
Clamp terminal - solid (mm2) 16 50 120 - - -
Clamp terminal - flexible (mm2) 10 50 120 - - -
Flat terminal (mm) - - 25 x 5 - - 80 x 10
Passing by hole (wire) through C.T. core (mm2) - - - - 400 -
Passing by hole (bar) through C.T. core (mm) - - - 30 x 10 30 x 10 -
Tightening torque (Nm) 2.5 4.5 6.5 23 31.5 -

Control circuit
Rated insulation voltage (V) 690
(IEC60947-4) Ui
Rated thermal current Ith (A) 10
Operation current
AC-15 - Ue-Ie (V - A) 110/120 - 3 ; 220/240 - 2 ; 380/415 - 1 ; 480/500 - 0,8 ; 660/690 - 0,3
A DC-13 - Ue-Ie (V - A) 24 - 2 ; 48 - 1.4 ; 110 - 0.6 ; 250 - 0.3 ; 440 - 0.1
Utilisation according UL and CSA B600 - Q600
Protective fuse type gL (A) 10
Terminal capacity (mm2) 2.5
B Tightening capacity (Nm) 0.8

C Conformity to standards Remote electrical reset


IEC/EN 60947-4-1 NFC 63-650 NI C 63-650 Power consumption
IEC/EN 60947-5-1 CEI 17-50 VDE 0660 AC (VA) 100
UNE 115 CSA 22.2/14 UL 508 DC (W) 100
D Coils not suitable for continuous operating duty

Approvals
E cULus
LLoyd’s Register
RINA
Bureau Veritas

t1 = 1 sec. ♦ t2 = 30 sec.
t1 = 5 sec. ♦ t2 = 90 sec.
F Ambient conditions t1 = 10 sec. ♦ t2 = 180 sec.
Storage temperature -40ºC to +70ºC
(t1 = ON time t2 = OFF time)
Operation temperature (compensated) -25ºC to +60ºC
Altitude up to 3000m w/o any changes
G Relative humidity
in characteristics
98%
Protection treatment Tropical finish

H
Mounting positions

C.68
Series RT
Tripping curves
RT1 Class 10A RT2 Class 10

Trip Time (s) Trip Time (s)

Technical data
Single phase Single phase
Cold state Cold state

Three phase Three phase


Cold state Cold state

A
Three phase Three phase
Warm state Warm state
. .
B
. .
. .
Multiples of setting current Multiples of setting current
C
RT12 Class 20 RT22 Class 20
D
Trip Time (s) Trip Time (s)

Single phase
Single phase
Cold state
G
Cold state

Three phase
Three phase
Cold state
H
Cold state

Three phase X
Three phase Warm state
Warm state
. .

. .
. .
Multiples of setting current Multiples of setting current

C.69
Series RT
Tripping curves
RT3 Class 10 RT4 Class 10

Trip Time (s) Trip Time (s)


Thermal overload relays

Single phase
Single phase
Cold state
Cold state

Three phase
Cold state Three phase
Cold state

A
Three phase Three phase
Warm state Warm state
. .
B
. .
. .
Multiples of setting current Multiples of setting current
C
RT32 Class 20 RT4L Class 30
D
Trip Time (s) Trip Time (s)

G Single phase
Cold state Single-phase
Cold state

Three phase
H Cold state
Three phase
Cold state

X Three phase
Warm state
Three phase
Warm state

. .

. .
. .
Multiples of setting current Multiples of setting current

C.70
Series RT
Tripping curves
RT5 Class 10 RT6 Class 10

Trip Time (s) Trip Time (s)

Technical data
Single phase Single phase
Cold state Cold state

Three phase Three phase


Cold state Cold state

A
Three phase Three phase
Warm state Warm state

. .
B
. .
. .
Multiples of setting current Multiples of setting current
C
RT5L Class 30 RT6L Class 30
D
Trip Time (s) Trip Time (s)

Single phase G
Cold state
Single phase
Cold state

Three phase Three phase H


Cold state Cold state

Three phase
Warm state Three phase X
Warm state

. .

. .
. .
Multiples of setting current Multiples of setting current

C.71
Series RT
Dimensional drawings
Thermal overload relay for contactors
RT1 - RT12 RT1 + RT XP
0.190 kg RT12 + RTXP

.
Thermal overload relays

. .
. . .

.
.

RT2 - RT22 RT2 + RT XP


0.400 kg RT22 + RTXP
.
.
. .

A
.

.
B . .

C
RT3 - RT32
0.900 kg
D

.
E

F
.

H
.

C.72
Series RT

Thermal overload relay for contactors


RT4LA...RT4LM
2.400 kg

. .

Dimensions
RT4/4LN...RT4/4LR
2.400 kg

B
. .

RT5 / 5L
0.875 kg
D
.
E

H
.

I
Remote electrical reset
RTXRR + ... X Z X
RT1 75 110
RT2 84 121
RT3 108 153
RT4 150 240
RT5 200 196

C.73
Series CSC
Contactors for capacitors switching
Contactors for capacitors switching

With built-in resistance to switch three phase


capacitor banks
“CSC” contactors incorporate a frontal block with three early-make auxiliary
contacts together with 6 quick discharge resistances (two per phase) through
which the capacitors are switched to the network, reducing the current peak.
Once the resistances have damped the current peak, the main contact short-
circuit the resistances, carrying the uninterrumpted current. A few miliseconds
later the early-make auxiliary contact drops to guarantee that all current flows
through the main contacts.

Standards Standard voltages


A IEC/EN 60947-1 CENELEC HD 419 To complete the catalogue number, replace the symbol © by the code
IEC/EN 60947-4-1 NFC 63-110 corresponding to the voltage and frequency of the control circuit (other
IEC/EN 60947-5-1 ASE 1025 voltages on request)
B EN 50005 UNE 20109 Alternating current (V). Dual-frequency
UL 508 VDE 0660/102 © 1 2 3 4 5 6 7 8 9 (1)
CSA C22.2/14
50/60Hz 24 42 110 120 220 230 240 440 48
C 115
Approvals Alternating current (V)
© E K L N T U W Y Z
D 50Hz 32 127 220 380 415 500 660
230 400 690
cULus 60Hz 208 277 380 480 460 600
E

C.74
Series CSC
Contactors for capacitors switching
Ith Ambient temperature Fuse Contacts Cat. no. (1) Pack
θ ≤ 55ºC θ ≤ 70ºC gl - gG 3
• •1
230V 400V 415V 500V 660V 230V 400V 415V 500V 660V Ref.
240V 690V 240V 690V no. see
A kvar kvar kvar kvar kvar kvar kvar kvar kvar kvar
•4 •2 bottom
25 7.5 12.5 13 16 15 3.7 7.5 8 9.5 10 25 2 0 CSC12A320 © 1
1 1 CSC12A311 © 1
0 2 CSC12A302 © 1
32 10 16.7 17 21 20 5 10 11 12.5 12.5 35 2 0 CSC16A320 © 1
1 1 CSC16A311 © 1
0 2 CSC16A302 © 1
45 12.5 20 21 25 25 7.5 12.5 13 16 15 40 1 0 CSC20A310 © 1
0 1 CSC20A301 © 1
2 1 CSC20A321 © 1
1 2 CSC20A312 © 1
45 15 25 26 31 30 10 15 16 18 20 50 1 0 CSC25A310 © 1
0 1 CSC25A301 © 1
2 1 CSC25A321 © 1
1 2 CSC25A312 © 1

Oder codes
60 20 30 31 38 35 16 22 23 27 25 63 1 0 CSC30A310 © 1
0 1 CSC30A301 © 1
2 1 CSC30A321 © 1
1 2 CSC30A312 © 1
90 25 45 47 56 55 20 35 36 44 40 80 1 0 CSC45A310 © 1
0 1 CSC45A301 © 1
2 0 CSC45A320 © 1
1 1 CSC45A311 © 1
1 2 CSC45A312 © 1
110 35 55 57 69 65 30 45 47 56 50 125 1 0 CSC55A310 © 1
0 1 CSC55A301 © 1
2 0 CSC55A320 © 1
1
1
1
2
CSC55A311 ©
CSC55A312 ©
1
1
A
140 45 70 73 88 85 35 60 62 75 70 160 1 0 CSC70A310 © 1
0 1 CSC70A301 © 1
2 0 CSC70A320 © 1
1
1
1
2
CSC70A311 ©
CSC70A312 ©
1
1
B

Spare coils CSC12 ... CSC 25 LB1A © 5


CSC30
CSC45 ... CSC70
LB3A ©
LB4A ©
5
5
C

D
(1) To complete the reference, replace © by the code corresponding to the voltage and frequency of the control circuit.

For reference numbers,


see chapter X, pg. X.4

C.75
Series CSC
Technical data
Contactors for capacitors switching

Technical characteristics
CSC12 CSC16 CSC20 CSC25 CSC30 CSC45 CSC55 CSC70
Main circuit (poles)
Rated operational voltage (V) 690 690 690 690 690 690 690 690
Rated insulation voltage according to IEC947(V) 1000 1000 1000 1000 1000 1000 1000 1000
Rated thermal current (A) 25 32 45 45 60 90 110 140
Max. power utilization 230/240V (kvar) 7,5 10 12,5 15 20 25 35 45
at 55ºC 380/400V (kvar) 12.5 16,7 20 25 30 45 55 70
660/690V (kvar) 15 20 25 30 35 55 65 85
Electrical endurance (ops.) 280.000 280.000 280.000 250.000 200.000 150.000 120.000 90.000
Max. ops./hour (ops./hour) 350 350 350 240 240 150 150 150

Control circuit
Standard voltages 50Hz (V) 24-690 24-690 24-690 24-690 24-690 24-690 24-690 24-690
60Hz (V) 24-600 24-600 24-600 24-600 24-600 24-600 24-600 24-600
Consumption
Single frequency Mar. circuit open (VA) 45 45 48 48 88 191 191 198
Mar. circuit closed (VA) 6 6 7 7 9 15,5 15,5 17
Dual frequency Mar. circuit open (VA) 54 54 58 58 125 245 245 250
50Hz Mar. circuit closed (VA) 7 7 8 8 11.5 20 20 23
Dual frequency Mar. circuit open (VA) 35 35 39 39 110 215 215 220
60Hz Mar. circuit closed (VA) 5 5 6 6 11 15 15 19

Instantaneous auxiliary contact blocks


A Rated insulation voltage Ui (V) 1000
Rated thermal current Ith (A) 10

Ambient conditions
B Storage temperature (ºC) -50 ... +80
Operating temperature (ºC) -25 to +55 (without derating)
Altitude up to 3000m Nominal values
C Mounting positions Vertical mounting +/- 30º

Terminal capacity and tightening torque


D CSC12 CSC16 CSC20 CSC25 CSC30 CSC45 CSC55 CSC70

Solid, stranded and finely stranded 1 x 0.5 ... 2,5 1 x 0.5 .. 2,5 – – –
without end sleeve (mm2) 1 x 2.5 ... 6 1 x 2.5 ... 10 – – –
E Finely stranded with or
without end sleeve (mm2)
1 x 1 ... 2,5
1 x 2.5 ... 6
1 x 1 ... 2,5
1 x 2.5 ... 10






AWG wires 1 x 20 ... 12 1 x 20 ... 8 – – –
Tightening torque Nm 1.6 2.2 – – –

F Solid, stranded and finely stranded


Lb x in. 15 20 – – –

without end sleeve (mm2) – – 0.75 ... 16 1 ... 35 1.5 ... 50


Finely stranded with end sleeve (mm2) – – 0.75 ... 16 1 ... 35 1.5 ... 50
Finely stranded without end sleeve (mm2) – – 1 ... 16 1 ... 35 1.5 ... 50
G AWG wires – – 18 ... 6 16 ... 2 16 ... 2
Tightening torque Nm – – 1.8 4 5.6
Lb x in. – – 16 35 50
Solid (mm2) – – 0.75 ... 16 1 ... 16 4 ... 35
H Stranded (mm2) – – 0.75 ... 16 1 ... 25 4 ... 35
Finely stranded without end sleeve (mm2) – – 0.75 ... 16 1 ... 25 4 ... 35
Finely stranded with end sleeve (mm2) – – 1 ... 16 1 ... 25 4 ... 35
AWG wires – – 18 ... 6 16 ... 4 10 ... 1
I Tightening torque Nm – – 1.8 4 5.6
Lb x in. – – 16 35 50
Solid, stranded and finely stranded – – Max. 16 Max. 50 ... 4 Max.
without end sleeve (mm2) – – Max. 25 ... 16 50 ... 35
X Finely stranded without end sleeve (mm2) – – Max. 16 Max. 35 ... 2,5
Max. 25 ... 16
Max. 35

Finely stranded with end sleeve (mm2) – – Max. 16 Max. 35 ... 16 Max. 35
Max. 25 ... 25
AWG wires – – Max. 6 Max. 2 ... 12 Max. 1
– – Max 4 ... 4
Tightening torque Nm – – 1.8 4 5.6
Lb x in. – – 16 35 50

C.76
Series CSC
Standard contactors

Series “CL“ and “CK“ contactors, to switch three phase capacitor banks
Electrical endurance: >100,000 operations
Contactor θ ≤ 55ºC θ ≤ 70ºC Fuse I max.
Type (1) Ith 220V 400V 415V 500V 690V 220V 400V 415V 500V 690V gl - gG (peak)
230V 660V 230V 660V
240V 240V
A kvar kvar kvar kvar kvar kvar kvar kvar kvar kvar A A
CL00A 25 3 5 5.5 6.5 5.7 2.4 4 4.5 5.2 4.5 10 1000
CL01A 25 4.5 9.5 10.5 12.5 11 3.6 6 6.5 10 7 16 1000
CL02A 32 6.5 11 12 14.5 12.5 5.2 8.5 9 11.5 10 25 1000
CL25A 45 7.5 12.5 14 16 15 6.5 10 11 13 12 25 1000

Technical data
CL03A 45 9 15 16.5 20 17.5 7.2 12 13 16 14 35 2500
CL04A 60 12.5 21 23 27.5 24 10 17 18 22 19.5 40 2500
CL45A 60 16.5 25 27 32 30 13 20 22 25 22 50 2500
CL06A 90 22 40 43 52 50 17 30 33 41 35 80 3500
CL07A 110 25 45 48 58 65 19 35 37 46 40 125 3500
CL08A 110 30 50 54 65 70 22 40 43 52 50 125 3500
CL09A 140 40 65 70 85 95 35 58 62 75 85 160 3500
CL10A 140 50 80 85 105 120 43 70 75 90 105 160 3500
CK75C 250 60 110 118 145 150 48 88 94 116 120 250 5000
CK08C 250 70 125 135 162 170 56 100 107 130 136 250 5000
CK85B 315 80 150 160 195 200 64 120 130 156 160 315 5000
CK09B 315 95 165 177 215 230 85 148 160 192 205 315 5000
CK95B 450 105 190 205 250 288 95 175 188 230 265 450 5500
CK10C 600
700
135 260 280 340 370 120 235 252 375 330 630 10000 A
CK11C 190 325 350 425 450 152 260 280 340 360 800 10000
CK12B 1000 250 400 430 520 600 200 320 344 416 480 1000 12000
CK13B 1250 315 525 565 685 650 252 420 452 548 520 1250 15000
(1) To complete contactor reference, see C.11 for CL and C.19 for CK B

C.77
Series CSC
Dimensional drawings
Contactors for capacitors switching

Contactors for capacitors switching


CSC12..., CSC16...
35 45 7.5

82.5
50

73
4.5 131
137.5

CSC20..., CSC25...
35 45 7.5

85.5
50
73

4.5 56 133
A 139.5

B
CSC30...
4.5 55 7.5

C 90.5
50
79

60

D 40 66 144
45 150.5

CSC45..., CSC55... 66 9
F
118.5
90

5.5
G
56 77 162
H 60 168.5

I
CSC70... 75 9

X
128.5
90

5.5

56 86 172
178.5

C.78
Series CSC
Notes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Dimensions
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

C.79
Series 390.R
Clapper contactors
40A to 800A (AC-3) / 45A to 1200A (AC-1)
AC and DC control using a bridge rectifier, designed to meet the most recent
stringent requirements in terms of reliability, service life and performance.

Main characteristics
• Sliding contact holder, set on self-centering and self-lubricating bronze
Clapper contactors

bushings
• Minitubes made of high-strength, high electrical resistance material
• Individual auxiliary contacts

Construction
Variable composition contactors (the number of main poles and auxiliary
contacts may vary), preferably secured on mounts

Control circuit
Solid iron magnetic circuit with coil powered by direct or rectified current,
Standards particularly for heavy-duty applications (e.g., cranes, roll mills, reversing
winches, etc.).
A IEC/EN 60947-1 The coils are sized for intermittent operation. For continuous operation, insert
IEC/EN 60947-4-1 an economy resistor in series with the coil using the respective auxiliary
IEC/EN 60947-5-1 contact.
B
Standard voltages Main contacts
Alternating current (V) Dual-frequency coils The sintered main contacts are classified as Type 4/2 for intermittent operation
C and Type 5/2 for continuous operation.
AP CP EP GP
The 4/2 sintered contact may be used only for heavy-duty operation when
50/60Hz 24 48 110 220 the number of switching operations per hour is above 60 and the operating
intermittence is equal or less than 60% (cranes, roll mills, etc.).
D Direct current (V) If used for continuous operation, the contact will overheat.
A B C D E F G H M R The 5/2 sintered contact may be used only for normal duty when the number
of switching operations per hour is equal to or less than 60% and the operating
Voltage 20 24 40 48 97 110 197 220 230 125
E intermittence is above 60%.

Auxiliary contacts
F Individual NO or NC single-breake contacts
Possibility to advance or delay contact making or breaking

G Special versions
The following items may be supplied upon request:
• Contactors with coils having an operating limit that exceeds the limits
H required by the standards
• Contactors with an operating voltage up to 3000V (rotary disconnect
switches, induction furnaces, etc.)
I • Vertical mechanical interlocks ideal for interlocking 3 contactors.

Spare parts and additional components


X Spare parts and additional components for the contactors are listed
on page C.85.
Order codes ! pg. C.81
Accessories and
replacement parts ! pg. C.85
Technical data ! pg. C.87
Dimensional drawings ! pg. C.90

C.80
Series 390.R
Control voltage and normal combinations
Normal rated voltages, shaft spacing and combinations (main and auxiliary
poles) have been defined for each switchgear unit, thereby allowing the con-
tactor to be rapidly selected.
AC rated voltages: 24V - 48V - 110V - 220/230V
DC rated voltages: 24V - 48V - 110V - 220/230V

Spacing between standarised shafts and combinations:


See pages C.90 to C.92
Standard center-to-center spacing (mm): 150, 200, 250, 300, 350, 400, 450, 500,
600, 700, 800, 900, 1000

Main poles

Order codes
The poles can be constructed as follows, depending on the operating conditions:

Z design (NO)
- For load breaking, with high breaking capacity
- For AC or DC use
- Equipped with magnetic arc-quenching coil. In the case of AC, the poles are normally sup
plied with an appropriate arc-quenching coil for the maximum rated current of the pole.
- Arc-quenching coils for medium rated currents with respect to the expected peak current
are available for DC use upon request, for more effective pole performance (see table
on page C.84). A
RN design (NC)
- Based on the use of break poles, which are open when the coil is energized and closed when B
the coil is de-energised.
- For AC or DC use in special circuits where high interrupting capacities are not required.
- This design is intended to be used with contactors R1, R2, R3, R4, R5, R7.
C
Poles R1 R2 R3 R4 R5 R6 R7 R8 R9
Z
RN
D

E
Order codes - Clapper contactors
Peak operating AC-3 admissible rated powers Electric AC or DC Pack.
current
Resistive Motors
endur. F
loads <440V, 220V 380V 415V 500V See the following
3~ 230V 400V 440V Cat. pages C.82 and
50/60Hz AC3 C.83 on how to
AC1 AC3 kW kW kW kW Switching complete the G
A A HP HP HP HP operations catalogue number
45 40 11,5 20 20 20 1 x 106 R1 . . . 1

90 90 26 45 45 45 1 x 10 6
R2 . . . 1 H
125 120 36.5 62 62 73.5 1 x 10 6
R3 . . . 1

250 200 72.5 100 100 120 1 x 10 6


R4 . . . 1

320 320 93 160 160 165 1.2 x 10 6


R5 . . . 1
I
450 450 130 225 225 300 1.5 x 106 R6 . . . 1

630 630 184 315 315 400 1 x 10 6


R7 . . . 1 X
800 800 232 400 400 500 0.9 x 10 6
R8 . . . 1

1500 - - - - - - R9 . . . 1

C.81

32764_C80_C92_E.indd 81 11-07-2005 16:28:21


Series 390.R
Catalogue number structure

1 2 3 4 5 6 7 8 9

Product Size Coil voltage Resistor No. No. No. “Z” poles
line NO aux. NC aux. “Z” poles
contacts contacts
Clapper contactors

Size 1 2 Auxiliary contacts 6 7 “RN” poles” (NC) 11


Ith NO NC “RN” poles “RN” poles
1 Max. 45 R 1 6 1 1 11 0 0 -
500V AC 90 R 2 2 2 1 1 1
250V DC 125 R 3 3 3 2 2 2
2 7
250 R 4 4 4 3 3 3
320 R 5 5 5 4 4 4
450 R 6 6 6
630 R 7 1 1 Note: The “RN” poles are not available for the
800 R 8 2 2 R6, R8 and R9 types.
1200 R 9 3

A 4
“RN” poles 12
Type of pole
Coil voltage 3 4 12 RN V
AC DC “Z” poles” (N) 8 No “RN” poles -
B 3 Types R1 ... R7 “Z” poles
24V A P 8 0 - Note: The “RN” poles are not available for the
48V C P R6, R8 and R9 types.
4 1 1
110V E P 2 2
C 220V G P 3 3
Arc- Standard Upon request
20V A - 4 4
24V B - quenching
40V C - coil «RN»
D 48V
97V
D
E
-
-
poles A B C
“Z” poles 9 Type
110V F -
Type of pole 13 R1 45A 14A 25A
197V G - 9 Z Z R2 90A 45A -
E 220V
230V
H
M
-
-
No “Z” poles - R3 125A 75A -
R4 200A 50A 130A
125V R -
R5 320A 150A -
Types R8 and R9
110V E P R6 - - -
F 220V 97V G P
Arc- Standard Upon request
R7 630A 320A -
110V E - R8 - - -
197V F - quenching R9 - - -
220V G - coil “Z”
G 230V H - poles A B C Note: The “RN” poles are not available for the
R6, R8 and R9 types.
125V M - Type
10 R1 45A 14A 25A
R2 90A 45A - Type of contacts 14
H Economy resistor 5
R3 125A 75A -
14
Type
R4 200A 50A 130A 4/2 Intermittent op. 4
R5 320A 150A - 5/2 Continuous op. 5
5 If required R
R6 450A 270A -
I (5/2 contacts)
If not required -
R7 630A 320A -
R8 800A 320A 400A
R9 1200A - -

C.82
Series 390.R

10 11 12 13 14 15 16 17 18

Arc-quen- No. “RN” “RN” poles Arc-quen- Type of Stationary Space Shaft Isolation
ching coil poles ching coil contacts support
“Z” poles “RN” poles

Contactor type Contactor type Isolation 18

Order codes
Statio- Schaft
nary R1 R4 R6 R9 (Hstat. R1 R4 R6 R9
18
support R2 R5 R7 sup.) R2 R5 R7 For more M
R3 R8 R3 R8 isolation
Length Length Not required -
15 (mm) 17 (mm)
150 A - - - 150 A - - -
200 B - - - 200 B - - -
250 C C - - 250 C C - -
300 D D - - 300 D D - -
350 E E E - 350 E E E -
400
450
F
G
F
G
F
G
F
G
400
450
F
G
F
G
F
G
F
G
A
500 H H H H 500 H H H H
600 I I I I 600 I I I I
700
800
L
M
L
M
L
M
L
M
700
800
L
M
L
M
L
M
L
M
B
900 N N N N 900 N N N N
1000 O O O O 1000 O O O O

C
Space 16 Stationary support Stationary support Stationary support

16
D
No space Station. sup. =Shaft -
Space Left S
Shaft Shaft Shaft
Right -
Stationary support = Shaft Space to left Space to right
E

C.83
Series 390.R
Standardised DC or rectified coils
The DC coils are suitable for intermittent operation; for continuous operation, an economy resistor must be used.
The coils for rectified rated voltages 20-40-97-197V obtained from AC power supplies. (before the rectifier). 24-48-110-220V are
available upon request. For the contactor of “RN” break poles, contact GE.
Contactor Voltage Coil Economy resistor Single-phase bridge rectifier
VDC for continuous operation ± 5% for AC power
Cat. no. Ref. no. W Ω Cat. no. Ref. no. V Cat. no. Ref. no.
50/60Hz
R1 20 39012Y20D 244107 4 8.2 RSS13/64TA8,2 204177 24 MSK-B250/220-1,5 209997
R2 24 39012Y24D 202327 18 RSS13/64TA18 211727 -
40 39012Y40D 244106 33 RSS13/64TA33 211728 48 MSK-B250/220-1,5 209997
Clapper contactors

48 39012Y48D 244734 68 RSS13/64TA6,8 214869 -


97 39012Y97D 202328 220 RSS13/64TA220 212702 110 MSK-B250/220-1,5 209997
110 39012Y110D 202323 330 RSS13/64TA330 211745 -
197 39012Y197D 202325 680 RSS13/64TA680 214580 220 MSK-B250/220-1,5 209997
220 39012Y220D 202326 1200 RSS13/64TA1200 213034 -
230 39012Y230D 211706 1200 RSS13/64TA1200 213034
125 39012Y125D 202324 330 RSS13/64TA300 211714

R3 20 3903Y20D 215278 4 8.2 RSS13/64TA8,2 204177 24 MSK-B250/220-1,5 209997


24 3903Y24D 244735 18 RSS13/64TA18 211727 -
40 3903Y40D 244088 39 RSS13/64TA39 211730 48 MSK-B250/220-1,5 209997
48 3903Y48D 212705 47 RSS13/64TA47 211731 -
97 3903Y97D 213691 270 RSS13/64TA270 214399 110 MSK-B250/220-1,5 209997
110 3903Y110D 202437 330 RSS13/64TA330 211745 -
197 3903Y197D 214442 820 RSS13/64TA820 214400 220 MSK-B250/220-1,5 209997
220 3903Y220D 202438 1200 RSS13/64TA1200 213034 -
230 3903Y230D 211107 1200 RSS13/64TA1200 213034
125 3903Y125D 216100 330 RSS13/64TA300 211714

A R4 20
24
3904Y20D
3904Y24D
244084
202483
6 8.2
18
RSS13/64TA8,2
RSS13/64TA18
204177
211727
24
-
MSK-B250/220-1,5 209997

40 3904Y40D 244083 33 RSS13/64TA33 211728 48 MSK-B250/220-1,5 209997


48 3904Y48D 213814 33 RSS13/64TA33 211728 -
97 3904Y97D 213601 180 RSS13/64TA180 211744 110 MSK-B250/220-1,5 209997
B 110
197
3904Y110D
3904Y197D
202479
202481
180
680
RSS13/64TA180
RSS13/64TA680
211744
214580
-
220 MSK-B250/220-1,5 209997
220 3904Y220D 202482 680 RSS13/64TA680 214580 -
230 3904Y230D 211708 680 RSS13/64TA680 214580
125 3904Y125D 202480 180 RSS13/64TA180 211744
C
R5 20 3905Y20D 244073 10 6.8 RSS13/64TA6,8 214869 24 SKB-B80/70-4 211716
24 3905Y24D 244072 10 RSS13/64TA10 211742 -
40 3905Y40D 244071 27 RSS13/64TA27 244192 48 MSK-B250/220-1,5 209997
48 3905Y48D 244736 27 RSS13/64TA27 244192 -
D 97 3905Y97D 202513 120 RSS13/64TA120 243281 110 MSK-B250/220-1,5 209997
110 3905Y110D 202512 180 RSS13/64TA180 211744 -
197 3905Y197D 244074 470 RSS13/64TA470 244191 220 MSK-B250/220-1,5 209997
220 3905Y220D 212706 680 RSS13/64TA680 214580 -
230 3905Y230D 211709 680 RSS13/64TA680 214580
E 125 3905Y125D 242260 180 RSS13/64TA180 211744

R6 20 3906Y20D 244065 10 6.8 RSS13/64TA6,8 214869 24 SKB-B80/70-4 211716


24 3906Y24D 244064 8.2 RSS13/64TA8,2 204177 -
40
F 48
3906Y40D
3906Y48D
244063
212707
27
27
RSS13/64TA27
RSS13/64TA27
244192
244192
48
-
MSK-B250/220-1,5 209997

97 3906Y97D 202533 100 RSS13/64TA100 211744 110 MSK-B250/220-1,5 209997


110 3906Y110D 202532 180 RSS13/64TA180 211744 -
197 3906Y197D 244066 470 RSS13/64TA470 244191 220 MSK-B250/220-1,5 209997
G 220
230
3906Y220D
3906Y230D
213612
211770
680
680
RSS13/64TA680
RSS13/64TA680
214580
214580
-

125 3906Y125D 211711 180 RSS13/64TA180 211744

R7 20 3907Y20D 244058 16 5.6 RSS13/64TA5,6 211735 24 SKB-B80/70-4 211716


H 24
40
3907Y24D
3907Y40D
244057
244056
5.6
15
RSS13/64TA5,6
RSS13/64TA15
211735
211737
-
48 SKB-B80/70-4 211716
48 3907Y48D 244737 18 RSS13/64TA18 211727 -
97 3907Y97D 244738 82 RSS13/64TA82 204177 110 MSK-B250/220-1,5209997
110 3907Y110D 202547 100 RSS13/64TA100 211743 -
I 197
220
3907Y197D
3907Y220D
244059
202548
330
390
RSS13/64TA330
RSS13/64TA390
211745
211746
220
-
MSK-B250/220-1,5209997

230 3907Y230D 211712 1200 RSS13/64TA1200 213034


125 3907Y125D 211713 330 RSS13/64TA330 211745

X R8 97
110
3908Y97D
3908Y110D
212959
202565
16 82
120
RSS20/165TA82
RSS20/165TA120
214081
213664
110
-
SKB-B250/220-4 212165

197 3908Y197D 214066 390 RSS20/165TA390 211748 220 MSK-B250/220-1,5 209997


220 3908Y220D 202566 470 RSS20/165TA470 211739 -

R9 97 3909Y97D 214146 140 100 RSS20/165TA100 213663 110 SKB-B30/08 211720


110 3909Y110D 202572 150 RSS20/165TA150 215004 -
197 3909Y197D 204181 390 RSS20/165TA390 211748 220 SKB-B500/445-4 214501
220 3909Y220D 244739 560 RSS20/165TA560 244987 -

(1) To insert the resistors, use NC auxiliary contacts in series.


(2) Two 20x165 resistors connected in parallel, each with a resistive value listed in the table.

C.84
Series 390.R
Spare parts
Contactor Description Cat. no. Ref. no. Pack
(units)
R1 “Z” stationary part with 14A arc-quenching coil and spark suppressor 390/3921PFZCS14 202273 1
“Z” stationary part with 25A arc-quenching coil and spark suppressor 390/3921PFZCS25 244172 1
“Z” stationary part with 45A arc-quenching coil and spark suppressor 390/3921PFZCS45 202274 1
“RN” stationary part with spark suppressor 390/3921PFRN 244173 1
“Z” moving part (with pressure spring and strap) 390/3921PMZI 202276 1
“RN” moving part (with pressure spring and strap) 390/3921PMRN 202275 1
Stationary and moving main contact, type 4/2 (intermittent operation) 390/3921/2FOM4/2 214120 1
Stationary and moving main contact, type 5/2 (continuous operation) 390/3922FOM5/2 214121 1
Spark suppressor for “Z” and “RN” poles 390/3921PZ 202277 1

R2 “Z” stationary part with 45A arc-quenching coil and spark suppressor 390/3922PFZCS45 244744 1
“Z” stationary part with 90A arc-quenching coil and spark suppressor 390/3922PFZCS90 202278 1
“RN” stationary part with spark suppressor 390/3922PFRN 212709 1

Order codes
“Z” moving part (with pressure spring and strap) 390/3922PMZI 202279 1
“RN” moving part (with pressure spring and strap) 390/3922PMRN 213014 1
Stationary and moving main contact, type 4/2 (intermittent operation) 390/3921/2FOM4/2 214120 1
Stationary and moving main contact, type 5/2 (continuous operation) 390/3922FOM5/2 214121 1
Spark suppressor for “Z” and “RN” poles 390/3922PZ 202280 1

R3 “Z” stationary part with 75A arc-quenching coil and spark suppressor 390/3923PFZCS75 244745 1
“Z” stationary part with 125A arc-quenching coil and spark suppressor 390/3923PFZCS125 202281 1
“RN” stationary part with spark suppressor 390/3923PFRN 213986 1
“Z” moving part (with pressure spring and strap)
“RN” moving part (with pressure spring and strap)
390/3923PMZI
390/3923PMRN
202283
202282
1
1
A
Stationary and moving main contact, type 4/2 (intermittent operation) 390/3923/2FOM4/2 214122 1
Stationary and moving main contact, type 5/2 (continuous operation) 390/3923FOM5/2 214123 1
Spark suppressor for “Z” and “RN” poles 390/3923PZ 202284 1
B

R4 “Z” stationary part with 125A arc-quenching coil and spark suppressor 390/3924PFZCS125
“Z” stationary part with 200A arc-quenching coil and spark suppressor 390/3924PFZCS200
202288
202289
1
1 C
“RN” stationary part with spark suppressor 390/3924PFRN 202287 1
“Z” moving part (with pressure spring and strap) 390/3924PMZI 202291 1
“RN” moving part (with pressure spring and strap) 390/3924PMRN 202290 1
Stationary main contact, type 4/2 (intermittent operation)
Moving main contact, type 4/2 (intermittent operation)
390/3924F4
390/3924M4/2
214124
214126
1
1 D
Stationary main contact, 5/2 type (continuous operation) 390/3924F5/2 204178 1
Moving main contact, type 5/2 (continuous operation) 390/3924M5/2 214127 1
Spark suppressor for “Z” and “RN” poles 390/3924PZ 202292 1
E

R5 “Z” stationary part with 125A arc-quenching coil and spark suppressor 390/3925PFZCS150
“Z” stationary part with 320A arc-quenching coil and spark suppressor 390/3925PFZCS320
213573
202295
1
1
F
“RN” stationary part with spark suppressor 390/3925PFRN 244746 1
“Z” moving part (with pressure spring and strap) 390/3925PMZI 202298 1
“RN” moving part (with pressure spring and strap) 390/3925PMRN 202297 1
Stationary main contact, type 4/2 (intermittent operation)
Moving main contact, type 4/2 (intermittent operation)
390/3925F4/2
390/3925M4/2
214128
214130
1
1
G
Stationary main contact, 5/2 type (continuous operation) 390/3925F5/2 214129 1
Moving main contact, type 5/2 (continuous operation) 390/3925M5/2 214131 1
Spark suppressor for “Z” and “RN” poles 390/3925PZ 202299 1
H

R5 “Z” stationary part with 270A arc-quenching coil and spark suppressor 390/3926PFZCS270
“Z” stationary part with 450A arc-quenching coil and spark suppressor 390/3926PFZCS450
202303
213574
1
1
I
“Z” moving part (with pressure spring and strap) 390/3926PMZI 202304 1
Stationary main contact, type 4/2 (intermittent operation) 390/3926F4/2 214133 1
Moving main contact, type 4/2 (intermittent operation) 390/3926M4/2 214135 1
Stationary main contact, 5/2 type (continuous operation)
Moving main contact, type 5/2 (continuous operation)
390/3926F5/2
390/3926M5/2
214134
214136
1
1
X
Spark suppressor for “Z” and “RN” poles 390/3926PZ 202654 1

C.85
Series 390.R
Spare parts (continued)
Contactor Description Cat. no. Ref. no. Pack
(units)
R7 “Z” stationary part with 320A arc-quenching coil and spark suppressor 390/3927PFZCS320 202307 1
“Z” stationary part with 630A arc-quenching coil and spark suppressor 390/3927PFZCS630 202308 1
“RN” stationary part with spark suppressor 390/3927PFRN 202306 1
“Z” moving part (with pressure spring and strap) 390/392PMZI 202310 1
“RN” moving part (with pressure spring and strap) 390/3927PMRN 202309 1
Stationary main contact, type 4/2 (intermittent operation) 390/3927F4/2 214137 1
Moving main contact, type 4/2 (intermittent operation) 390/3927M4/2 214139 1
Stationary main contact, 5/2 type (continuous operation) 390/3927F5/2 214138 1
Moving main contact, type 5/2 (continuous operation) 390/3927M5/2 214140 1
Spark suppressor for “Z” and “RN” poles 390/3927PZ 202311 1
Clapper contactors

R8 “Z” stationary part with 400A arc-quenching coil and spark suppressor 3908PFZCS400 202555 1
“Z” stationary part with 800A arc-quenching coil and spark suppressor 3908PFZCS800 202562 1
“Z” moving part (with pressure spring and strap) 3908PMZ 202563 1
Stationary main contact, type 4/2 (intermittent operation) 3908F4/2 214144 1
Moving main contact, type 4/2 (intermittent operation) 3908/9M4/2 214141 1
Stationary main contact, 5/2 type (continuous operation) 3908F5/2 214145 1
Moving main contact, type 5/2 (continuous operation) 3908/9M5/2 214142 1
Spark suppressor for “Z” and “RN” poles 3908PZ 202564 1

R8 “Z” stationary part with 1200A arc-quenching coil and spark suppr. 3909PFZCS120 244983 1
“Z” moving part (with pressure spring and strap) 3909PMZ 212962 1
A Stationary main contact, type 4/2 (intermittent operation)
Moving main contact, type 4/2 (intermittent operation)
3909F4/2
3908/9M4/2
204179
214141
1
1
Stationary main contact, 5/2 type (continuous operation) 3909F5/2 204180 1
Moving main contact, type 5/2 (continuous operation) 3908/9M5/2 214142 1

C.86
Series 390.R
Operating categories
R1... R2... R3... R4... R5... R6... R7... R8... R9...

AC-1 Peak operating current 40ºC (A) 45 90 125 250 320 450 630 800 1200
at ambient temp. of: 55ºC (A) 45 90 125 250 320 450 600 750 1200
(for all rated voltages) 70ºC (A) 30 70 100 200 280 360 500 700 950
Max. operating power 230/220V (kW) 17 30 45 90 114 170 195 240 450
Resistor III 400/380V (kW) 29 55 75 155 196 310 330 410 750
440/415V (kW) 32 57 85 180 227 340 330 500 900
500V (kW) 39 69 102 200 250 390 420 550 1030
Conductor (mm2) 10 35 50 120 185 2 x (30x5) 2 x (40x5) 2 x (60x5) 4 x (50x5)
Operation in % of peak 120 ops./h (%) 100 100 100 100 100 100 100 100 50
operating current 300 ops./h (%) 50 50 50 50 30 30 20 10 10

AC-3 Peak operating current Ue = 400V (A) 40 90 110 200 320 450 630 800 -
Max. operating power 230/220V (kW) 11.5 26 36.5 72.5 93 130 184 232 -

Technical data
400/380V (kW) 20 45 62 100 160 225 315 400 -
440/415V (kW) 20 45 68 100 160 225 315 400 -
500V (kW) 20 45 72,5 120 165 280 400 500 -
Use in % of peak 120 ops./h (%) 100 100 100 100 100 100 100 100 -
operating current 300 ops./h (%) 50 50 50 50 50 50 30 30 -

AC-4 Peak operating current Ue = 500V (A) 18.5 44 55 110 125 150 165 250 -
Operating power 230/220V (kW) 4 11 15 33 37 45 50 80 -
(200,000 switching (HP) 5.3 14.6 19.9 43.9 49.2 59.8 66.5 106 -
400/380V (kW) 9 22 28 55 63 80 90 132 -
(HP) 11.9 29.2 37.2 73.1 83.8 106 119.7 175.5 -
500V (kW) 11 25 33 75 90 100 110 225 -
(HP) 14.6 33.2 43.9 99.7 119.7 133 146 299 -
Peak operating current H 400V (A) 40 90 110 185 280 420 590 700 - A
Max. operating power 400/380V (kW) 18.5 38 55 90 150 220 300 375 -

R1... R2... R3... R4... R5... R6... R7... R8... R9...


Ue Series poles
40 85 115 180 300 400 600 700 900
B
DC1 125V 1
L/R H 1ms 2 60 90 125 200 320 450 630 750 1000
3 60 90 125 200 320 450 630 800 1250

220V
4
1
60
20
90
75
125
110
200
160
320
275
450
350
630
500
800
600
1250
800
C
2 30 90 115 200 300 370 560 650 900
3 40 90 125 250 320 400 630 750 1000

440V
4
1
40
-
90
-
125
-
250
-
320
-
450
-
630
-
800
-
1250
-
D
2 - 75 100 200 275 350 500 600 800
3 20 90 125 250 320 400 600 700 900
4 20 90 125 250 320 450 630 800 1000
E
DC3 125V 1 30 75 100 170 280 380 550 650 -
L/R H 2.5ms 2 40 80 110 200 320 450 630 800 -
3 45 90 110 200 320 450 630 800 -
4 45 100 120 220 340 480 - - - F
220V 1 - - - - - - - - -
2 15 65 90 155 245 340 460 550 -
3 20 90 110 200 320 450 630 800 -

440V
4
1
25
-
90
-
110
-
200
-
320
-
450
-
630
-
800
-
-
-
G
2 - - - - - - - - -
3 10 55 75 120 200 300 400 500 -
4 13 70 100 160 260 400 550 660 -
H
DC5 125V 1 27 50 70 90 240 320 400 500 -
L/R H 15ms 2 35 70 90 150 280 380 450 550 -
3 40 90 100 200 320 420 500 600 -
4 40 90 110 200 320 450 500 650 - I
220V 1 - - - - - - - - -
2 13 55 80 140 220 300 410 490 -
3 18 80 100 180 290 400 560 700 -
4 22 80 100 180 290 400 560 700 - X
440V 1 - - - - - - - - -
2 - - - - - - - - -
3 9 50 67 100 180 270 360 450 -
4 11 60 90 130 224 360 480 600 -

C.87
Series 390.R
Technical data
Standards Maintenance
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1 C = Opening of the moving core
C1 = Opening of moving core
when the contacts start to
touch. The data listed in the
Ambient conditions table refers to contactors in
Storage temperature -55°C to +80°C a normal three-pole design
and may vary in the case of
Operating temperature -40°C to +60°C
special designs.
Clapper contactors

Altitude up to 2500m Rated values


3000 to 4000m 90%Ie 80%Ue
4000 to 5000m 80%Ie 75%Ue

Climatic withstand capacity (IEC 68-2)


Continuous testing 40/125/56 DC power supply Pressure of closed
Cold (72h) Temperature -40°C C C1 contact in kg
Dry heat (96h) Temperature +125°C (mm) ±1 (mm) ±1 (+10% / -30%)
Relative humidity < 50% 18 5 0.750
Moist heat (56 days) Temperature +40°C 18 5 0.750
Relative humidity 95% 20 6 0.750
Cyclic testing 22 6 1.300
First half-cycle (12h) Low temperature +25°C 24 7 2.000
Relative humidity 93% 28 8 3.500
A Second half-cycle (12h) Low temperature +55°C 28 8 5.500
Relative humidity 95% 34 10 8.000
No. consecutive cycles 6 34 10 15.000

B
Mounting positions Replacement of main contact
The replacement (due to wear) of the main contacts requires an adjust-

C ment to ensure proper distance between the moving and the stationary
contacts. The respective adjustment screws should be turned until the
main contacts start to touch simultaneously when the gap indicated by
A1 or C1 exists between the stationary and the moving magnetic circuit.
Make sure that all contactor poles have the same stroke by manually
D closing the magnetic circuit; if the poles are properly adjusted, they
should come into contact at the same time.
If contact wear is abnormal, please contact the manufacturer since the
apparatus has been improperly chosen for the application conditions.
E No variation in on and off voltage.
To replace the contacts, loosen the screw securing the contacts to the
respective contact holder, making sure that the screws are well-tight-
No variation in rated power
ened when installing the new contacts.
GE Power Controls warrants proper operation of the contactors only if
F the contacts are replaced with OEM contacts.

G Capacity of terminals and torque


R1... R3... R4... R5... R6... R7... R8... R9...
R2...

H Single-core conductor (mm2) 2.5...25 2.5...50


Multi-strand conductor (mm2) 2.5...25 2.5...50
with terminal sheath
Multi-strand conductor (mm2) 2.5...25 2.5...50
I without terminal sheath
Multi-strand (mm2) 4...25 4...50
Single- and multi-strand AWG (mm2) 16...4 16...2
Torque (Nm) 4 5,6
X Multi-strand with terminal
(Lb x in)
(mm2)
35 50
1 x 120 1 x 185 - - -
2 x 95 2 x 150
Clappers - - 2 x (30x5) 2 x (40x5) 2 x (60x5)
Torque (Nm) 7 23 31 31 31
(Lb x in) 60 200 275 275 275

C.88
Series 390.R
Power circuit
R1... R2... R3... R4... R5... R6... R7... R8... R9...

Thermal rated current lth at u H 55ºC (A) 45 90 125 250 320 450 630 800 1500
Rated operating current Ie AC-3 (A) 40 90 110 200 320 450 630 800 -
Rated operating voltage Ue (1) (V) 500 500 500 500 500 500 500 500 500

3-pole contactors
Rated isolation voltage Ui (V) 1000 1000 1000 1000 1000 1000 1000 1000 1000
Maximum continuous current AC-1 (A) 45 90 125 250 320 450 630 800 1200
Frequency limits (Hz) (Hz)
Making capacity (RMS) (IEC947) (A) 540 1200 1250 2400 3800 5400 7500 9600 4000
Breaking capacity (RMS) (IEC 947) Ue ≤ 400V (A) 450 960 1250 1900 3050 4350 6000 7700 4000
Ue = 500V (A) - 650 1050 1900 3050 4350 6000 7700 4000
Short-time current 1 s. (A) 1200 1500 2000 2500 3000 4250 5000 6000 10000
5 s. (A) 800 900 1500 2200 2800 4000 4800 5700 9000

Technical data
10 s. (A) 500 650 1200 1600 2500 3900 4600 5500 8800
30 s. (A) 250 300 750 1100 2000 3700 4400 5200 8500
1 min. (A) 180 200 450 800 1500 2500 3000 4000 5000
3 min. (A) 100 150 250 500 600 900 1500 2300 3000
Recovery time (min.) 10 10 10 10 10 10 10 10 10
Fused short-circuit protection aM (A) 50 125 160 250 400 630 800 1000 -
gL-gG (A) 80 160 200 315 425 630 800 1000 -
Impedance per pole (mΩ) 1 1 0.5 0.4 0.2 0.3 0.2 0.25 0.10
Power dissipated per pole AC-1 (W) 2.1 8.1 7.8 25 20 60 79 160 144
AC-3 (W) 1.6 8.1 6 16 20 60 79 160 -
Isolation resistance
Pole-to-pole (mΩ) >10 >10 >10 >10 >10 >10 >10 >10 >10
Pole-to-ground
Input-to-output
(mΩ)
(mΩ)
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
A
(1) For rated voltages above 500V, contact the manufacturer.

Control circuit B
Alternating current R1... R2... R3... R4... R5... R6... R7... R8... R9...

Rated isolation voltage Ui (V) 1000 1000 1000 1000 1000 1000 1000 1000 1000
Standardized voltages Us at 50/60 Hz (V) 24...220 24...220 24...220 24...220 24...220 24...220 24...220 24...220 24...220
Single-frequency coil voltage limits
C
Operation xUs 0.85...1.1 0.85...1.1 0.85...1.1 0.85...1.1 0.85...1.1 0.85...1.1 0.85...1.1 0.85...1.1 0.85...1.1
Off xUs 0.22...0.55 0.22...0.55 0.22...0.55 0.22...0.55 0.22...0.55 0.22...0.55 0.22...0.55 0.22...0.55 0.22...0.55
Consumption of dual-frequency coils (1)
Closed magnetic circuit (50 Hz/60 Hz) (VA) 19 19 20 25 35 38 53 100 190 D
Open magnetic circuit (50 Hz/60Hz) (VA) 27 27 38 41 57 60 90 440 1400
Dissipated thermal power (50 Hz/60 Hz) (W) 19 19 20 25 35 38 53 100 190
On and off times. Values at Us
Making time at de-energisation (NA) (ms) 60/70 60/70 60/70 110/120 150/160 180/200 200/210 150/160 - E
Making time at de-energisation (NA) (ms) 80/95 80/95 80/95 160/170 200/210 350/450 240/250 150/160 -
Mechanical endurance
Dual-frequency coils (at 50 Hz) 106 ops. 10 10 10 10 10 10 10 8 8
Maximum rate F
Dual-frequency coils. No-load ops./h 1200 1200 600 400 400 400 400 300 300
AC-1 with rated power ops./h 600 600 300 120 120 120 120 90 60
AC-2 with rated power ops./h 250 250 200 120 120 120 120 90 -
AC-3 with rated power
AC-4 with rated power
ops./h
ops./h
600
150
600
150
300
100
120
60
120
60
120
60
120
60
90
30
-
-
G
Direct current
Rated isolation voltage Ui (V) 1000 1000 1000 1000 1000 1000 1000 1000 1000
Standardized voltages Us (V) 24...230 24...230 24...230 24...230 24...230 24...230 24...230 24...230 24...230
H
Voltage limits
Operating xUs 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1
Off xUs 0.15...0.5 0.15...0.5 0.15...0.5 0.15...0.5 0.15...0.5 0.15...0.5 0.15...0.5 0.15...0.5 0.15...0.5
Power consumption I
Closed magnetic circuit (W) 14 14 16 22 28 30 42 80 140
Open magnetic circuit (W) 21 21 25 31 45 46 65 400 1000
On and off time
Values at Us X
Making time at energization (NA) (ms) 60/70 60/70 60/70 110/120 150/160 180/200 200/210 150/160 -
Breaking time at de-energization (NA) (ms) 19/20 19/20 19/20 28/30 40/45 59/60 30/35 25/30 -
Mechanical endurance 106 ops. 10 10 10 10 10 10 10 8 8
Maximum rate
No-load ops./h 1200 1200 600 400 400 400 400 300 300
AC1 and AC3 with rated power ops./h 600 600 300 120 120 120 120 90 -
AC4 with rated power ops./h 150 150 100 60 60 60 60 30 -
(1) With 5/2 contact

C.89
Series 390.R
Dimensional drawings
R1..., R2...
Contact combination
“Z” main Max. no. of Max.Max. Center-to-
pole (1) aux. contacts NO NC center spacing
1 1 1 1 150
3 3 3 200
6 6 4 250
9 6 4 300
10 6 4 350
10 6 4 400
Clapper contactors

2 1 1 1 200
4 4 4 250
7 6 4 300
9 6 4 350
9 6 4 400
3 2 2 2 250
5 5 4 300
7 6 4 350
7 6 4 400
4 2 2 2 300
5 5 4 350
5 5 4 400
(1) A “RN” pole can be used to replace one of the
“Z” poles. To use a higher number of “RN” poles,
contact the manufacturer.

R3...
A Contact combination
“Z” main Max. no. of Max.Max. Center-to-
pole (1) aux. contacts NO NC center spacing
B 1 -
3
-
3 3
- 150
200
6 6 4 250
9 6 4 300
10 6 4 350
C 2
10
-
6 4
- -
400
200
3 3 3 250
6 6 4 300
8 6 4 350
D 3
9
-
6 4
- -
400
250
3 3 3 300
6 6 4 350
7 6 4 400
E 4 -
3
-
3 3
- 300
350
4 4 4 400
(1) A “RN” pole can be used to replace one of the
“Z” poles. To use a higher number of “RN” poles,
F contact the manufacturer.

R4...
G
Contact combination
“Z” main Max. no. of Max.Max. Center-to-
pole (1) aux. contacts NO NC center spacing
H 1 3
6
3 3
6 4
250
300
9 6 4 350
10 6 4 400
10 6 4 450
I 2 -
3
-
3 3
- 250
300
6 6 4 350
9 6 4 400
10 6 4 450
X 3 -
3
-
3 3
- 300
350
6 6 4 400
9 6 4 450
4 3 3 3 400
4 4 3 450
(1) A “RN” pole can be used to replace one of the
“Z” poles. To use a higher number of “RN” poles,
contact the manufacturer.

C.90
Series 390.R

R5...
Contact combination
“Z” main Max. no. of Max.Max. Center-to-
pole (1) aux. contacts NO NC center spacing
1 2 2 2 250
5 5 4 300
8 6 4 350
10 6 4 400
10 6 4 450
10 6 4 500
2 2 2 2 300
4 4 4 350
7 6 4 400
10 6 4 450
10 6 4 500
3 1 - - 350

Dimensions
4 4 4 400
6 6 4 450
7 6 4 500
4 - - - 400
3 3 3 450
3 3 3 500
(1) A “RN” pole can be used to replace one of the
“Z” poles. To use a higher number of “RN”
poles, contact the manufacturer.

R6...
Contact combination
A
“Z” main Max. no. of Max. Max. Center-to-
aux. contacts NO NC center spacing
1 5
8
2
6
4
4
350
400
B
10 6 4 450
10 6 4 500
10 6 4 600

2
10
1
6
1
4
1
700
350
C
4 4 4 400
7 6 4 450
9 6 4 500

3
10
10
6
6
4
4
600
700
D
2 2 2 450
5 5 4 500
7 6 4 600

4
7
1
6
1
4
1
700
500
E
2 2 2 600
2 2 2 700

R7...
G
Contact combination
“Z” main Max. no. of Max.Max. Center-to-
pole (1) aux. contacts NO NC center spacing
1 4
6
4
6
4
4
350
400
H
9 6 4 450
10 6 4 500
10 6 4 600

2
10
1
6
1
4
1
700
400
I
4 4 4 450
7 6 4 500
10 6 4 600

3
10
1
6
1
4
1
700
500
X
7 6 4 600
8 6 4 700
4 2 2 2 600
5 5 3 700
(1) A “RN” pole can be used to replace one of the
“Z” poles. To use a higher number of “RN”
poles, contact the manufacturer.

C.91
Series 390.R

Dimensional drawings
R8...
Contact combination
“Z” main Max. no. of Max. Max. Center-to-
aux. contacts NO NC center spacing
1 1 1 1 350
4 4 4 400
6 6 4 450
9 6 4 500
10 6 4 600
10 6 4 700
Clapper contactors

10 6 4 800
2 - - - 450
3 3 3 500
8 6 4 600
10 6 4 700
10 6 4 800
3 2 2 2 600
8 6 4 700
8 6 4 800
4 1 1 1 700
4 3 3 800

R9...
A
Contact combination
“Z” main Max. no. of Max. Max. Center-to-
aux. contacts NO NC center spacing
B 1 2
4
2
4
2
4
400
450
7 6 4 500
10 6 4 600
10 6 4 700
C 10
10
6
6
4
4
800
900
10 6 4 1000
2 4 4 4 600
9 6 4 700
D 10
10
6
6
4
4
800
900
10 6 4 1000
3 - - - 700
6 6 4 800
E 8 6 4 900
8 6 4 1000
4 3 3 3 900
4 3 3 1000

C.92
Motorstarters
SURION - Fuseless starters
D.2 Fuseless starters
D.4 Busbar adapter plates
D.5 Coordination tables
D.14 Dimensions

Series M, CL, CK - Direct-on-line starters


D.19 Order codes
D.24 Diagrams
D.32 Dimensions

Series M, CL, CK - Reversing starters


D.20 Order codes
D.28 Diagrams
D.34 Dimensions

Series CL, CK - Star-delta starters


D.22 Order codes
D.30 Diagrams
D.37 Dimensions

Applications Plug-in relays and Auxiliary contactors A


D.39 Utilisation categories
D.42 Electrical endurance
D.46 DC utilisation categories Motor protection devices B
Selection tables
D.49 Direct-on-line starters Contactors and Thermal overload relays C
D.53 Star-delta starters
D.57 Autotransformer starters
Motorstarters D

D.59 Contactors for rotor starters


D.60 Contactors for rotor speed drives
Control and signalling units E
D.62 Contactors for connection of power transformers
D.63 Contactors for capacitors (category AC6b)
D.64 Contactors for control lighting circuits
Electronic relays F

ASTAT S - Softstarters
D.67 Order codes
Limit switches G
D.68 Diagrams
D.69 Performance
D.70 Dimensions Speed drive units H
ASTAT SD - Softstarters
D.73 Order codes Main switches I
D.74 Diagrams
D.76 Dimensions
Numerical index X
ASTATplus - Softstarters
D.80 Order codes
D.81 I/O terminal board stpecifications
D.82 Installation
D.84 Diagrams
D.88 Dimensions

D.1
Surion
Fuseless starters and busbar adapter plates
Manual motorstarter

Product range
A
• Link modules for mechanical and electrical connection of the manual motor
starter and the M / CL contactor range
• Base plates for Din rail and busbar adapters
B • Wiring kits for reversing applications
• Link connection for two base plates for three phase busbar system with 40
and 60mm center line spacing and 5 to 10mm thickness
C • Accessories

D
Technical performances
E • Compact and high performance solution
• Easy accessibility to the contactor coil terminal A1-A2
• Save spacing only using 45 and 55mm width base plates for busbar
adapters
F • Quick “clip on” and secure connections
• Minimum 50kA short-circuit breaking capacity applies throughout

For fuseless starter application turn the contactor 180° to have direct
H accessibility to the A1-A2 coil terminals when contactor is assembled to the
Thermal and
magnetic protection manual motor starter. Then fit the contactor plastic cover into the contactor
GPS1B ! pg. B.8 front to have the terminal numbering in the correct position.
I GPS2B ! pg. B.10 Note: when turning the contactor 180° the built-in auxiliary contact (in case)
GPS1M ! pg. B.12 will be located on the first left side terminal.
GPS2M ! pg. B.14

X Contactors
Serie M ! pg. C.2
Serie CL ! pg. C.10

Coordination tables ! pg. D.5


Dimensions ! pg. D.14

D.2
Surion
Fuseless starters
Description For use with ac/dc Frame size Cat. no. Ref. no. Pack.
contactor
Link modules For mechanical and electrical MC0.., MC1.. ac/dc GPS1 GPF1LMCBA 101410 5
connection between contactors CL00A.., CL01A.., CL02A.. ac GPS1 GPF1L02AA 101411 5
and manual motor starters CL00D.., CL01D.., CL02D.. dc GPS1 GPF1L02DA 101412 5
CL25A.. ac GPS1 GPF1L25AA 101413 5
CL25D.. dc GPS1 GPF1L25DA 101414 5
CL03A.., CL04A ac GPS1 GPF1L04AA 107165 5
CL03D.., CL04D dc GPS1 GPF1L04DA 107166 5

CL03A.., CL04A.. ac GPS2 GPF2L04AA 107190 5


CL45A.. ac GPS2 GPF2L45AA 101415 5
CL03D.., CL04D.. dc GPS2 GPF2L04DA 107191 5
CL45D.. dc GPS2 GPF2L45DA 101416 5
CL06A.., CL07A.. ac GPS2 GPF2L07AA 101417 5
For use with MCCB - - - GPF3L09AA 107252 1
Record Plus withCL09/10A
For mechanical and electrical CL00.. - CL25 ac/dc GPS1 GPF1L25CT1 101512 5
connection between contactor CL03.. - CL45 ac/dc GPS2 GPF1L45CT1 101513 5

Order codes
and thermal overload relays RT1

Base plates Plastic plates for mounting the CL00.., CL01..,CL02..,CL25.. ac/dc GPS1 GPF1B1A 101418 5
fuseless starter in panels or in 35 CL03..,CL04... and CL45.. ac/dc GPS2 GPF2B2A 101419 5
mm DIN rail CL06..,CL07.. ac/dc GPS2 GPF2B3A 101420 5
CL03.., CL04.. ac/dc GP GPF1B4A 107163 5

Base plates For use with MCCB Record Plus - - - GPF3B5A 107253 1

Link For two base plates for - - - GPF1CBA 101427 10


connector reversing applications

A
Wiring kits Suitable to be usd with link MC0.., MC1.., MC2.. ac/dc WKMIU 101421 1
for reversing modules CL00.., CL01.., CL02.. ac/dc WKLI02P 101422 1
starters Upper and lower connections CL25.. ac/dc WKLI25P 101423 1
without overload relays CL03.., CL04...
CL45..
ac/dc
ac/dc
WKLI04P
WKLI45P
101424
101425
1
1
B
CL06A.., CL07A. ac WKLI07P 101426 1

Description For use with Cat. no. Ref. no. Pack. C


contactor
Plastic cover Fit the plastic cover into the front CL00.., CL01.. and CL02 GPF00C02 107098 5
of the correspondent contactor without built-in auxiliary contact
to allow a clear identification of CL00.., CL01.. and CL02 GPF10C02 107099 5
the terminal numbering with built-in 1NO auxiliary contact D
CL00.., CL01.. and CL02 GPF01C02 107100 5
with built-in 1NC auxiliary contact
CL25.. GPF00C25 107101 2
CL03.., CL04.. GPF00C04 107102 5
without built-in auxiliary contact E
CL03.., CL04.. GPF10C04 107103 5
with built-in 1NO auxiliary contact
CL03.., CL04.. GPF01C04 107105 5
with built-in 1NC auxiliary contact
CL45.. GPF00C45 107106 5 F
CL06.., CL07.. GPF00C08 107107 5

D.3
Surion
Busbar adapter plates
Description Width/length Rating Frame size Contactor Cat. no. Ref. no. Pack.
(mm) (A)
For manual 40 mm centre 45/139 32 GPS1 - PBF13ECBA 107138 1
motor starter line spacing 54/139 32 GPS2 - PBF13FCBA 107139 1
mounted alone 54/139 63 GPS2 - PBF13FDBA 107140 1

60 mm centre 45/182 32 GPS1 - PBF23ECBA 107142 1


line spacing 54/182 32 GPS2 - PBF23FCBA 107143 1
54/182 63 GPS2 - PBF23FDBA 107145 1
Manual motorstarter

For fuseless 40 mm centre 45/182 32 GPS1 MC0/MC1 PBF13EBCA 107146 1


starter line spacing 45/182 32 GPS1 CL00/01/02/25 PBF13EBDA 107147 1
applications 55/182+60 (1) 32 GPS1 CL03/04 PBF13ECDA 107148 1
55/182+60 (1) 63 GPS2 CL04/45 PBF13FDEA 107149 1
63/182 63 GPS2 CL06/07 PBF13GDFA 107150 1

60 mm centre 45/182 32 GPS1 MCO/MC1 PBF23EBCA 107151 1


line spacing 45/182 32 GPS1 CL00/25 PBF23EBDA 107152 1
55/182+60 (1) 32 GPS1 CL03/04 PBF23ECDA 107153 1
55/182+60 (1) 63 GPS2 CL04/45 PBF23FDEA 107155 1
63/228 63 GPS2 CL06/07 PBF23GDFA 107156 1

For reversing 60 mm centre 45/182 - - MCO/MC1/CL00 PBF2AEAHA 107157 1


applications line spacing base CL01/CL02/CL25
A without contacts 55/182
63/182
-
-
-
-
CL03/CL04/CL45 PBF2AFAHA 107158
CL06/CL07 PBF2AGAHA 107159
1
1

C
(1) Using 60 mm extension base.

Accessories for busbar adapters


D Description Width Cat. no. Ref. no. Pack.

Side module For adapter shoes extension (10 mm) 13.5 mm PBFAABALA 107160 1

E
Plastic clip To couple 2 plates easily (Set of 20 pcs) PBFAAAAMA 107161 1
F

G Spacer Including screws PBFAAAANA 107162 1

H Busbar support
3 poles
40 mm centre line spacing
60 mm centre line spacing
PBF1AAAPA 107380
PBF2AAAQA 107381
2
2

I
Cover cap 40/60 mm PBFCAFAN-A 107382 1

End cover PBF2AAARA 107383 2

D.4
Surion
Technical data
Surion GPS-B: Coordination Type 1 65kA at 380/400V and 415V
MOTOR (1) MANUAL MOTOR STARTER CONTACTOR LINKS

Rated Rated current Cat. no. Rated Thermal Magnetic Series Smallest Minimum Cat. no.
power (A) current current current wire frontal (3)
In Cu electrical
Setting (PVC)(2) safety
range 380/415V clearance
2
(kW) 380/400V 415V (A) (A) (A) (mm ) (mm)
0.06 0.23 0.21 GPS1BSAB 0.25 0.16 - 0.25 3.2 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.09 0.34 0.31 GPS1BSAC 0.4 0.25 - 0.4 5.2 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.12 0.44 0.4 GPS1BSAD 0.63 0.4 - 0.63 8.2 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.18 0.65 0.63 GPS1BSAE 1 0.63 - 1 13 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.25 0.9 0.8 GPS1BSAE 1 0.63 - 1 13 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*

Technical data
0.37 1.25 1.1 GPS1BSAF 1.6 1 - 1.6 20.5 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.55 1.6 1.5 GPS1BSAF 1.6 1 - 1.6 20.5 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.75 2 1.9 GPS1BSAG 2.5 1.6 - 2.5 32.5 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
1.1 2.6 2.5 GPS1BSAH 4 2.5 - 4 52 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
1.5 3.5 3.4 GPS1BSAH 4 2.5 - 4 52 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
2.2 5 4.5 GPS1BSAJ 6.3 4 - 6.3 82 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
3 7 6.5 GPS1BSAK 10 6.3 - 10 130 MC1 / CL00 1.5 20 GPF1LMCBA / GPF1L02*
4 9 8 GPS1BSAK 10 6.3 - 10 130 MC1 / CL00 1.5 20 GPF1LMCBA / GPF1L02*
5.5 12 11 GPS1BHAL 13 9 - 13 169 CL01 2.5 20 GPF1L02*
7.5 16 14 GPS1BHAM 16 11 - 16 208 CL02 2.5 20 GPF1L02*
11 22.5 21 GPS1BHAP 25 19 - 25 325 CL25 4 20 GPF1L25*
15 30 28 GPS1BHAR 32 24 - 32 416 CL04 6 20 GPF1L04*
11
15
22.5
30
21
28
GPS2BHAP
GPS2BHAR
25
32
19 - 25
24 - 32
325
416
CL04
CL04
4
6
20
20
GPF2L04*
GPF2L04*
A
18.5 37 35 GPS2BHAS 40 28 - 40 520 CL45 10 20 GPF2L45*
22 44 41 GPS2BHAT 50 35 - 50 650 CL06 10 25 GPF2L07AA
30 60 55 GPS2BHAU 63 45 - 63 820 CL07 16 25 GPF2L07AA
B
Surion GPS-B: Coordination Type 2 65kA at 380/400V and 415V
MOTOR (1) MANUAL MOTOR STARTER CONTACTOR LINKS C
Rated Rated current Cat. no. Rated Thermal Magnetic Series Smallest Minimum Cat. no.
power (A) current current current wire frontal (3)
In Cu electrical
Setting (PVC)(2) safety D
range 380/415V clearance
2
(kW) 380/400V 415V (A) (A) (A) (mm ) (mm)
0.06 0.23 0.21 GPS1BHAB 0.25 0.16 - 0.25 3.2 CL00 1 20 GPF1L02*
0.09
0.12
0.34
0.44
0.31
0.4
GPS1BHAC
GPS1BHAD
0.4
0.63
0.25 - 0.4
0.4 - 0.63
5.2
8.2
CL00
CL00
1
1
20
20
GPF1L02*
GPF1L02*
E
0.18 0.65 0.63 GPS1BHAE 1 0.63 - 1 13 CL00 1 20 GPF1L02*
0.25 0.9 0.8 GPS1BHAE 1 0.63 - 1 13 CL00 1 20 GPF1L02*
0.37 1.25 1.1 GPS1BHAF 1.6 1 - 1.6 20.5 CL00 1 20 GPF1L02*
0.55 1.6 1.5 GPS1BHAF 1.6 1 - 1.6 20.5 CL00 1 20 GPF1L02*
F
0.75 2 1.9 GPS1BHAG 2.5 1.6 - 2.5 32.5 CL00 1 20 GPF1L02*
1.1 2.6 2.5 GPS1BHAH 4 2.5 - 4 52 CL25 1 20 GPF1L25*
1.5 3.5 3.4 GPS1BHAH 4 2.5 - 4 52 CL25 1 20 GPF1L25*
2.2 5 4.5 GPS1BHAJ 6.3 4 - 6.3 82 CL25 1 20 GPF1L25* G
3 7 6.5 GPS1BHAK 10 6.3 - 10 130 CL25 1.5 20 GPF1L25*
4 9 8 GPS1BHAK 10 6.3 - 10 130 CL25 1.5 20 GPF1L25*
5.5 12 11 GPS1BHAL 13 9 - 13 169 CL25 2.5 20 GPF1L25*
7.5 16 14 GPS1BHAM 16 11 - 16 208 CL25 2.5 20 GPF1L25* H
11 22.5 21 GPS1BHAP 25 19 - 25 325 CL25 4 20 GPF1L25*
15 30 28 GPS1BHAR 32 24 - 32 416 CL04 6 20 GPF1L04*
11 22.5 21 GPS2BHAP (4) 25 19 - 25 325 CL04 4 20 GPF2L04*
15 30 28 GPS2BHAR (4) 32 24 - 32 416 CL04 6 20 GPF2L04* I
18.5 37 35 GPS2BHAS (4) 40 28 - 40 520 CL45 10 20 GPF2L45*
22 44 41 GPS2BHAT (4) 50 35 - 50 650 CL06 10 25 GPF2L07*
30 60 55 GPS2BHAU (4) 63 45 - 63 820 CL07 16 25 GPF2L07*
(1) Currents are relevant to four pole motors not having special characteristics of torque. X
Inrush currents: 8 time rated current for 1s.
(2) The minimum cycle cross-sections are referred to an ambient temperature of 30°C max. in free air.
Cables are to withstand the maximum let-through energy and the motor rated current. Besides the user should consider the drop voltage on
the cables, the type of laying and the ambient temperature.
(3) Complete cat. nrs., see page D.3
(4) Test running.

D.5
Surion
Surion GPS-B: Coordination Type 1 50kA at 500V and 525V
MOTOR (1) MANUAL MOTOR STARTER CONTACTOR LINKS

Rated Rated current Cat. no. Rated Thermal Magnetic Series Smallest Minimum Cat. no.
power (A) current current current wire frontal (3)
In Cu electrical
Setting (PVC)(2) safety
range 380/415V clearance
2
(kW) 500V 525V (A) (A) (A) (mm ) (mm)
0.06 0.17 0.16 GPS1BSAB 0.25 0.16 - 0.25 3.2 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.09 0.24 0.22 GPS1BSAB 0.25 0.16 - 0.25 3.2 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.12 0.33 0.3 GPS1BSAC 0.4 0.25 - 0.4 5.2 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
Manual motorstarter

0.18 0.48 0.46 GPS1BSAD 0.63 0.4 - 0.63 8.2 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.25 0.66 0.64 GPS1BSAE 1 0.63 - 1 13 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.37 0.9 0.85 GPS1BSAE 1 0.63 - 1 13 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.55 1.2 1.15 GPS1BSAF 1.6 1 - 1.6 20.5 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.75 1.5 1.45 GPS1BSAF 1.6 1 - 1.6 20.5 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
1.1 2.1 1.9 GPS1BSAG 2.5 1.6 - 2.5 32.5 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
1.5 2.8 2.6 GPS1BSAH 4 2.5 - 4 52 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
2.2 3.9 3.6 GPS1BSAH 4 2.5 - 4 52 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
3 5.3 5 GPS1BSAJ 6.3 4 - 6.3 82 MC0 / CL00 1 20 GPF1LMCBA / GPF1L02*
4 6.8 6.5 GPS1BHAK 10 6.3 - 10 130 MC1 / CL00 1 20 GPF1LMCBA / GPF1L02*
5.5 9.1 8.6 GPS1BHAK 10 6.3 - 10 130 CL00 1.5 20 GPF1L02*
7.5 12 11.4 GPS1BHAL 13 9 - 13 169 CL01 2.5 20 GPF1L02*
10 15.5 14.8 GPS1BHAM 16 11 - 16 208 CL02 2.5 20 GPF1L02*
11 17.6 17 GPS1BHAN 20 14 - 20 260 CL25 2.5 20 GPF1L25*
15 23 22 GPS1BHAP 25 19 - 25 325 CL25 4 20 GPF2L25*
18.5 28.5 27 GPS1BHAR 32 24 - 32 416 CL04 6 20 GPF1L04*
11 17.6 17 GPS2BHAN 20 14 - 20 260 CL04 2.5 20 GPF2L04*
A 15 23 22 GPS2BHAP 25 19 - 25 325 CL04 4 20 GPF2L04*
18.5 28.5 27 GPS2BHAR 32 24 - 32 416 CL04 6 20 GPF2L04*
22 33 31.5 GPS2BHAS 40 28 - 40 520 CL45 6/10 20 GPF2L45*
30 45 43 GPS2BHAT 50 35 - 50 650 CL06 10 25 GPF2L07*
B 37 53 52 GPS2BHAU 63 45 - 63 820 CL07 16 25 GPF2L07*

Surion GPS-B: Coordination Type 2 50kA at 500V and 525V


C MOTOR (1) MANUAL MOTOR STARTER CONTACTOR LINKS

Rated Rated current Cat. no. Rated Thermal Magnetic Series Smallest Minimum Cat. no.
power (A) current current current wire frontal (3)
D In
Setting
Cu
(PVC)(2)
electrical
safety
range 380/415V clearance
2
(kW) 500V 525V (A) (A) (A) (mm ) (mm)
0.06 0.17 0.16 GPS1BS/HAB 0.25 0.16- 0.25 3.2 MC1 / CL00 1 20 GPF1LMCBA / GPF1L02*
E 0.09 0.24 0.22 GPS1BS/HAB 0.25 0.16 - 0.25 3.2 MC1 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.12 0.33 0.3 GPS1BS/HAC 0.4 0.25 - 0.4 5.2 MC1 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.18 0.48 0.46 GPS1BS/HAD 0.63 0.4– 0.63 8.2 MC1 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.25 0.66 0.64 GPS1BS/HAE 1 0.63 - 1 13 MC1 / CL00 1 20 GPF1LMCBA / GPF1L02*
F 0.37 0.9 0.85 GPS1BS/HAE 1 0.63 - 1 13 MC1 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.55 1.2 1.15 GPS1BS/HAF 1.6 1 - 1.6 20.5 MC1 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.75 1.5 1.45 GPS1BS/HAF 1.6 1 - 1.6 20.5 MC1 / CL00 1 20 GPF1LMCBA / GPF1L02*
1.1 2.1 1.9 GPS1BS/HAG 2.5 1.6 – 2.5 32.5 CL00 1 20 GPF1L02*
G 1.5
2.2
2.8
3.9
2.6
3.6
GPS1BS/HAH
GPS1BS/HAH
4
4
2.5 - 4
2.5 - 4
52
52
CL25
CL25
1
1
20
20
GPF1L25*
GPF1L25*
3 5.3 5 GPS1BS/HAJ 6.3 4 - 6.3 82 CL25 1 20 GPF1L25*
4 6.8 6.5 GPS1BHAK 10 6.3 – 10 130 CL25 1 20 GPF1L25*

H 5.5
7.5
9.1
12
8.6
11.4
GPS1BHAK
GPS1BHAL
10
13
6.3 – 10
9 – 13
130
169
CL25
CL25
1.5
2.5
20
20
GPF1L25*
GPF1L25*
10 15.5 14.8 GPS1BHAM 16 11 – 16 208 CL25 2.5 20 GPF1L25*
11 17.6 17 GPS1BHAN 20 14 - 20 260 CL25 2.5 20 GPF1L25*
15 23 22 GPS1BHAP 25 19 - 25 325 CL04 4 20 GPF1L04*
I 18.5 28.5 27 GPS1BHAR 32 24 - 32 416 CL04 6 20 GPF1L04*
11 17.6 17 GPS2BHAN 20 14 - 20 260 CL04 2.5 20 GPF2L04*
15 23 22 GPS2BHAP 25 19 - 25 325 CL04 4 20 GPF2L04*
18.5 28.5 27 GPS2BHAR 32 24 - 32 416 CL45 6 20 GPF2L45*
X 22 33 31.5 GPS2BHAS 40 28 – 40 520 CL06 6/10 25 GPF2L07*
30 45 43 GPS2BHAT 50 35– 50 650 CL06 10 25 GPF2L07*
37 53 52 GPS2BHAU 63 45 - 63 820 CL07 16 25 GPF2L07*
(1) Currents are relevant to four pole motors not having special characteristics of torque. Inrush currents: 8 time rated current for 1s.
(2) The minimum cycle cross-sections are referred to an ambient temperature of 30°C max. in free air. Cables are to withstand the maximum let-through
energy and the motor rated current. Besides the user should consider the drop voltage on the cables, the type of laying and the ambient temperature.
(3) Complete cat. nrs., see page D.3

D.6
Surion
Surion GPS-M and Record Plus: Coordination Type 1 65kA at 380/400V and 415V
MOTOR (1) BREAKER CONTACTOR OVERLOAD RELAY

Rated Rated current Cat. no. Rated Magnetic Magnetic Series Series Setting Smallest Min
power (A) current setting Im current range wire Cu frontal
In Pick-up band (PVC) (2) safety
± 20% Im 380/415V clearance
2
(kW) 380/400V 415V (A) (A) (A) (mm ) (mm)
0.06 0.23 0.21 GPS1MSAB 0.25 - 3.3 CL00 RT1B 0.16-0.26 1 20
0.09 0.34 0.31 GPS1MSAC 0.4 - 5.2 CL00 RT1C 0.25-0.41 1 20
0.12 0.44 0.4 GPS1MSAD 0.63 - 8.2 CL00 RT1D 0.4-0.65 1 20
0.18 0.65 0.63 GPS1MSAE 1 - 13 CL00 RT1D 0.4-0.65 1 20
0.25 0.9 0.8 GPS1MSAE 1 - 13 CL00 RT1F 0.65-1.1 1 20
0.37 1.25 1.1 GPS1MSAF 1.6 - 20.8 CL00 RT1G 1-1.5 1 20
0.55 1.6 1.5 GPS1MSAF 1.6 - 20.8 CL00 RT1H 1.3-1.9 1 20
0.75 2 1.9 GPS1MSAG 2.5 - 32.5 CL00 RT1J 1.8-2.7 1 20

Technical data
1.1 2.6 2.5 GPS1MSAH 4 - 52 CL00 RT1K 2.5-4 1 20
1.5 3.5 3.4 GPS1MSAH 4 - 52 CL00 RT1K 2.5-4 1 20
2.2 5 4.5 GPS1MSAJ 6.3 - 81.9 CL00 RT1L 4-6.3 1 20
3 7 6.5 GPS1MSAK 10 - 130 CL00 RT1M 5.5-8.5 1.5 20
4 9 8 GPS1MSAK 10 - 130 CL00 RT1N 8-12 1.5 20
5.5 12 11 GPS1MHAL 13 - 169 CL01 RT1P 10-16 2.5 20
7.5 - 14 GPS1MHAM 16 - 208 CL02 RT1P 10-16 2.5 20
7.5 16 - GPS1MHAM 16 - 208 CL02 RT1S 14.5-18 2.5 20
11 22.5 21 GPS1MHAP 25 - 325 CL25 RT1U 21-26 4 20
15 30 28 GPS1MHAR 32 - 416 CL04 RT1V 25-32 6 20
11 22.5 21 GPS2MHAP 25 - 325 CL04 RT1U 21-26 4 20
15 30 28 GPS2MHAR 32 - 416 CL04 RT1V 25-32 6 20
18.5 37 35 GPS2MHAS 40 - 520 CL45 RT1W 30-40 10 20
22 - 40 GPS2MHAT 50 - 650 CL06 RT2E 30-43 10 25 A
22 44 - GPS2MHAT 50 - 650 CL06 RT2G 42-55 10 25
30 60 55 GPS2MHAU 63 - 819 CL07 RT2H 54-65 16 25
45 85 80 FDH36MC100GD 100 1000 - 1500 1140 CL09 RT2L 78 – 97 35 30
55 - 100 FDH36MC160JF 160 1600 - 2400 1400 CL10 RT2M 90 - 110 35 30 B
55 105 - FDH36MC160JF 160 1600 - 240 1400 CL10 RT2M 90 - 110 35 30

Surion GPS-M and Record Plus: Coordination Type 2 65kA at 380/400V and 415V C
MOTOR (1) BREAKER CONTACTOR OVERLOAD RELAY

Rated Rated current Cat. no. Rated Magnetic Magnetic Series Series Setting Smallest Min
power (A) current setting Im
In Pick-up band
current range wire Cu
(PVC) (2)
frontal
safety
D
± 20% Im 380/415V clearance
(kW) 380/400V 415V (A) (A) (A) (mm2) (mm)
0.06 0.23 0.21 GPS1MHAB 0.25 - 3.3 CL00 RT1B 0.16-0.26 1 20
0.09 0.34 0.31 GPS1MHAC 0.4 - 5.2 CL00 RT1C 0.25-0.41 1 20 E
0.12 0.44 0.4 GPS1MHAD 0.63 - 8.2 CL00 RT1D 0.4-0.65 1 20
0.18 0.65 0.63 GPS1MHAE 1 - 13 CL00 RT1D 0.4-0.65 1 20
0.25 0.9 0.8 GPS1MHAE 1 - 13 CL00 RT1F 0.65-1.1 1 20
0.37 1.25 1.1 GPS1MHAF 1.6 - 20.8 CL00 RT1G 1-1.5 1 20 F
0.55 1.6 1.5 GPS1MHAF 1.6 - 20.8 CL00 RT1H 1.3-1.9 1 20
0.75 2 1.9 GPS1MHAG 2.5 - 32.5 CL00 RT1J 1.8-2.7 1 20
1.1 2.6 2.5 GPS1MHAH 4 - 52 CL25 RT1K 2.5-4 1 20
1.5 3.5 3.4 GPS1MHAH 4 - 52 CL25 RT1K 2.5-4 1 20 G
2.2 5 4.5 GPS1MHAJ 6.3 - 81.9 CL25 RT1L 4-6.3 1 20
3 7 6.5 GPS1MHAK 10 - 130 CL25 RT1M 5.5-8.5 1.5 20
4 9 8 GPS1MHAK 10 - 130 CL25 RT1N 8-12 1.5 20
5.5
7.5
12
-
11
14
GPS1MHAL
GPS1MHAM
13
16
-
-
169
208
CL25
CL25
RT1P
RT1P
10-16
10-16
2.5
2.5
20
20
H
7.5 16 - GPS1MHAM 16 - 208 CL25 RT1S 14.5-18 2.5 20
11 22.5 21 GPS2MHAP 25 - 325 CL25 RT1U 21-26 4 20
15
11
30
22.5
28
21
GPS2MHAR
GPS2MHAP
32
25
-
-
416
325
CL04
CL04
RT1V
RT1U
25-32
21-26
6
4
20
20
I
15 30 28 GPS2MHAR 32 - 416 CL04 RT1V 25-32 6 20
18.5 37 35 GPS2MHAS 40 - 520 CL45 RT1W 30-40 10 20
22 - 40 GPS2MHAT 50 - 650 CL06 RT2E 30-43 10 25
22 44 - GPS2MHAT 50 - 650 CL06 RT2G 42-55 10 25 X
30 60 55 GPS2MHAU 63 - 819 CL07 RT2H 54-65 16 25
45 85 80 FDH36MC100GD 100 1000 - 1500 1140 CL09 RT2L 78 – 97 35 30
55 - 100 FDH36MC100GD 100 1000 - 1500 1400 CL10 RT2M 90 - 110 35 30
55 105 - FDH36MC160JF 160 1600 - 2400 1400 CL10 RT2M 90 - 110 35 30
(1) Current are relevant to four pole motors not having special characteristics of torque. Inrush currents: H 8 time rated current for H 1s.
(2) The minimum cycle cross-sections are referred to an ambient temperature of 30ºC max. in free air and are selected to withstand the maximum let-through
energy and the motor rated current. Besides the user has to consider the drop voltage, the type of laying and ambient temperature.

D.7
Surion
Surion GPS-B: Coordination Type 2 50kA at 380/400V and 415V
MOTOR (1) MANUAL MOTOR STARTER CONTACTOR LINKS

Rated Rated current Cat. no. Rated Thermal Magnetic Series Smallest Minimum Cat. no.
power (A) current current current wire frontal (3)
In Cu electrical
Setting (PVC)(2) safety
range 380/415V clearance
2
(kW) 380/400V 415V (A) (A) (A) (mm ) (mm)
0.06 0.23 0.21 GPS1BS/HAB 0.25 0.16 - 0.25 3.2 MC1 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.09 0.34 0.31 GPS1BS/HAC 0.4 0.25 - 0.4 5.2 MC1 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.12 0.44 0.4 GPS1BS/HAD 0.63 0.4 - 0.63 8.2 MC1 / CL00 1 20 GPF1LMCBA / GPF1L02*
Manual motorstarter

0.18 0.65 0.63 GPS1BS/HAE 1 0.63 - 1 13 MC1 / CL00 1 20 GPF1LMCBA / GPF1L02*


0.25 0.9 0.8 GPS1BS/HAE 1 0.63 - 1 13 MC1 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.37 1.25 1.1 GPS1BS/HAF 1.6 1 - 1.6 20.5 MC1 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.55 1.6 1.5 GPS1BS/HAF 1.6 1 - 1.6 20.5 MC1 / CL00 1 20 GPF1LMCBA / GPF1L02*
0.75 2 1.9 GPS1BS/HAG 2.5 1.6 - 2.5 32.5 MC1 / CL00 1 20 GPF1LMCBA / GPF1L02*
1.1 2.6 2.5 GPS1BS/HAH 4 2.5 - 4 52 CL01 1 20 GPF1L02*
1.5 3.5 3.4 GPS1BS/HAH 4 2.5 - 4 52 CL01 1 20 GPF1L02*
2.2 5 4.5 GPS1BS/HAJ 6.3 4 - 6.3 82 CL02 1 20 GPF1L02*
3 7 6.5 GPS1BS/HAK 10 6.3 - 10 130 CL25 1.5 20 GPF1L25*
4 9 8 GPS1BS/HAK 10 6.3 - 10 130 CL25 1.5 20 GPF1L25*
5.5 12 11 GPS1BHAL 13 9 - 13 169 CL25 2.5 20 GPF1L25*
7.5 16 14 GPS1BHAM 16 11 - 16 208 CL25 2.5 20 GPF1L25*
11 22.5 21 GPS1BHAP 25 19 - 25 325 CL25 4 20 GPF1L25*
15 30 28 GPS1BHAR 32 24 - 32 416 CL04 6 20 GPF1L04*
11 22.5 21 GPS2BHAP 25 19 - 25 325 CL04 4 20 GPF2L04*
15 30 28 GPS2BHAR 32 24 - 32 416 CL04 6 20 GPF2L04*
18.5 37 35 GPS2BHAS 40 28 - 40 520 CL45 10 20 GPF2L45*
A 22 44 41 GPS2BHAT 50 35 - 50 650 CL06 10 25 GPF2L07*
30 60 55 GPS2BHAU 63 45 - 63 820 CL07 16 25 GPF2L07*
(1) Currents are relevant to four pole motors not having special characteristics of torque.
Inrush currents: H 8 time rated current for H 1s.
B (2) The minimum cycle cross-sections are referred to an ambient temperature of 30°C max. in free air. Cables are to withstand the maximum let-through
energy and the motor rated current. Besides the user should consider the drop voltage on the cables, the type of laying and the ambient temperature.
(3) Complete cat. nrs., see page D.3

D.8
Surion
Surion GPS-M and Record Plus: Coordination Type 1 65kA at 380/400V and 415V
MOTOR (1) BREAKER CONTACTOR OVERLOAD RELAY

Rated Rated current Cat. no. Rated Thermal Magnetic Series Series Setting Smallest Min
power (A) current current current range wire Cu frontal
In (PVC) (2) safety
380/415V clearance
2
(kW) 380/400V 415V (A) (A) (A) (mm ) (mm)
0.06 0.23 0.21 GPS1MS/HAB 0.25 - 3.3 CL00 RT1B 0.16-0.26 1 20
0.09 0.34 0.31 GPS1MS/HAC 0.4 - 5.2 CL00 RT1C 0.25-0.41 1 20
0.12 0.44 0.4 GPS1MS/HAD 0.63 - 8.2 CL00 RT1D 0.4-0.65 1 20
0.18 0.65 0.63 GPS1MS/HAE 1 - 13 CL00 RT1D 0.4-0.65 1 20
0.25 0.9 0.8 GPS1MS/HAE 1 - 13 CL00 RT1F 0.65-1.1 1 20
0.37 1.25 1.1 GPS1MS/HAF 1.6 - 20.8 CL00 RT1G 1-1.5 1 20
0.55 1.6 1.5 GPS1MS/HAF 1.6 - 20.8 CL00 RT1H 1.3-1.9 1 20
0.75 2 1.9 GPS1MS/HAG 2.5 - 32.5 CL00 RT1J 1.8-2.7 1 20

Technical data
1.1 2.6 2.5 GPS1MS/HAH 4 - 52 CL00 RT1K 2.5-4 1 20
1.5 3.5 3.4 GPS1MS/HAH 4 - 52 CL00 RT1K 2.5-4 1 20
2.2 5 4.5 GPS1MS/HAJ 6.3 - 81.9 CL00 RT1L 4-6.3 1 20
3 7 6.5 GPS1MS/HAK 10 - 130 CL00 RT1M 5.5-8.5 1.5 20
4 9 8 GPS1MS/HAK 10 - 130 CL00 RT1N 8-12 1.5 20
5.5 12 11 GPS1MHAL 13 - 169 CL01 RT1P 10-16 2.5 20
7.5 - 14 GPS1MHAM 16 - 208 CL02 RT1P 10-16 2.5 20
7.5 16 - GPS1MHAM 16 - 208 CL02 RT1S 14.5-18 2.5 20
11 22.5 21 GPS1MHAP 25 - 325 CL25 RT1U 21-26 4 20
15 30 28 GPS1MHAR 32 - 416 CL04 RT1V 25-32 6 20
11 22.5 21 GPS2MHAP 25 - 325 CL25 RT1U 21-26 4 20
15 30 28 GPS2MHAR 32 - 416 CL04 RT1V 25-32 6 20
18.5 37 35 GPS2MHAS 40 - 520 CL45 RT1W 30-40 10 20
22 - 40 GPS2MHAT 50 - 650 CL06 RT2E 30-43 10 25 A
22 44 - GPS2MHAT 50 - 650 CL06 RT2G 42-55 10 25
30 60 55 GPS2MHAU 63 - 819 CL07 RT2H 54-65 16 25
37 72 68 FDN36MC080GD 80 - 950 CL08 RT2J 64-82 25 25
45 85 80 FDN36MC100GD 100 - 1140 CL09 RT2L 78-97 35 30 B
55 105 100 FDN36MC100GD 100 - 1400 CL10 RT2M 90-110 35 30

Surion GPS-M and Record Plus: Coordination Type 2 50kA at 380/400V and 415V C
MOTOR (1) BREAKER CONTACTOR OVERLOAD RELAY

Rated Rated current Cat. no. Rated Thermal Magnetic Series Series Setting Smallest Min
power (A) current current current range wire Cu frontal D
In (PVC) (2) safety
380/415V clearance
(kW) 380/400V 415V (A) (A) (A) (mm2) (mm)
0.06 0.23 0.21 GPS1MS/HAB 0.25 - 3.3 CL00 RT1B 0.16-0.26 1 20
0.09 0.34 0.31 GPS1MS/HAC 0.4 - 5.2 CL00 RT1C 0.25-0.41 1 20 E
0.12 0.44 0.4 GPS1MS/HAD 0.63 - 8.2 CL00 RT1D 0.4-0.65 1 20
0.18 0.65 0.63 GPS1MS/HAE 1 - 13 CL00 RT1D 0.4-0.65 1 20
0.25 0.9 0.8 GPS1MS/HAE 1 - 13 CL00 RT1F 0.65-1.1 1 20
0.37 1.25 1.1 GPS1MS/HAF 1.6 - 20.8 CL00 RT1G 1-1.5 1 20 F
0.55 1.6 1.5 GPS1MS/HAF 1.6 - 20.8 CL00 RT1H 1.3-1.9 1 20
0.75 2 1.9 GPS1MS/HAG 2.5 - 32.5 CL00 RT1J 1.8-2.7 1 20
1.1 2.6 2.5 GPS1MS/HAH 4 - 52 CL01 RT1K 2.5-4 1 20
1.5 3.5 3.4 GPS1MS/HAH 4 - 52 CL01 RT1K 2.5-4 1 20 G
2.2 5 4.5 GPS1MS/HAJ 6.3 - 81.9 CL02 RT1L 4-6.3 1 20
3 7 6.5 GPS1MS/HAK 10 - 130 CL25 RT1M 5.5-8.5 1.5 20
4 9 8 GPS1MS/HAK 10 - 130 CL25 RT1N 8-12 1.5 20
5.5 12 11 GPS1MHAL 13 - 169 CL25 RT1P 10-16 1.5 20 H
7.5 - 14 GPS1MHAM 16 - 208 CL25 RT1P 10-16 2.5 20
7.5 16 - GPS1MHAM 16 - 208 CL25 RT1S 14.5-18 2.5 20
11 22.5 21 GPS1MHAP 25 - 325 CL25 RT1U 21-26 4 20
15
11
30
22.5
28
21
GPS1MHAR
GPS2MHAP
32
25
-
-
416
325
CL04
CL04
RT1V
RT1U
25-32
21-26
6
4
20
20
I
15 30 28 GPS2MHAR 32 - 416 CL04 RT1V 25-32 6 20
18.5 37 35 GPS2MHAS 40 - 520 CL45 RT1W 30-40 6 20
22
22
-
44
40
-
GPS2MHAT
GPS2MHAT
50
50
-
-
650
650
CL06
CL06
RT2E
RT2G
30-43
42-55
10
10
25
25
X
30 60 55 GPS2MHAU 63 - 819 CL07 RT2H 54-65 16 25
37 72 68 FDN36MC080GD 80 - 950 CL08 RT2J 64-82 25 25
45 85 80 FDN36MC100GD 100 - 1140 CL09 RT2L 78-97 35 30
55 105 100 FDN36MC100GD 100 - 1400 CL10 RT2M 90-110 35 30

(1) Current are relevant to four pole motors not having special characteristics of torque. Inrush currents: H 8 time rated current for H 1s.
(2) The minimum cycle cross-sections are referred to an ambient temperature of 30ºC max. in free air and are selected to withstand the maximum
let-through energy and the motor rated current. Besides the user has to consider the drop voltage, the type of laying and ambient temperature.

D.9
Surion
Surion GPS-M and Record Plus: Coordination Type 1 50kA at 500 and 525V
MOTOR (1) BREAKER CONTACTOR OVERLOAD RELAY
Rated Rated current Cat. no. Rated Magnetic Magnetic Series Series Setting Smallest Min
power (A) current setting Im current range wire Cu frontal
In Pick-up band (PVC) (2) safety
± 20% Im 380/415V clearance
2
(kW) 500V 525V (A) (A) (A) (mm ) (mm)
0.06 0.17 0.16 GPS1MSAB 0.25 - 3.2 CL00 RT1B 0.16-0.26 1 20
0.09 0.24 0.22 GPS1MSAB 0.25 - 3.2 CL00 RT1B 0.16-0.26 1 20
0.12 0.33 0.3 GPS1MSAC 0.4 - 5.2 CL00 RT1C 0.25-0.41 1 20
0.18 0.48 0.46 GPS1MSAD 0.63 - 8.2 CL00 RT1D 0.4-0.65 1 20
Manual motorstarter

0.25 - 0.64 GPS1MSAE 1 - 13 CL00 RT1D 0.4-0.65 1 20


0.25 0.66 - GPS1MSAE 1 - 13 CL00 RT1F 0.65-1.1 1 20
0.37 0.9 0.85 GPS1MSAE 1 - 13 CL00 RT1F 0.65-1.1 1 20
0.55 1.2 1.15 GPS1MSAF 1.6 - 20.5 CL00 RT1G 1.0-1.5 1 20
0.75 1.5 1.45 GPS1MSAF 1.6 - 20.5 CL00 RT1H 1.3-1.9 1 20
1.1 2.1 1.9 GPS1MSAG 2.5 - 32.5 CL00 RT1J 1.8-2.7 1 20
1.5 2.8 2.6 GPS1MSAH 4 - 52 CL00 RT1K 2.5-4 1 20
2.2 3.9 3.6 GPS1MSAH 4 - 52 CL00 RT1K 2.5-4 1 20
3 5.3 5 GPS1MSAJ 6.3 - 82 CL00 RT1L 4.0-6.3 1 20
4 6.8 6.5 GPS1MHAK 10 - 130 CL00 RT1M 5.5-8.5 1 20
5.5 9.1 8.6 GPS1MHAK 10 - 130 CL00 RT1N 8.0-12.0 1.5 20
7.5 12 11.4 GPS1MHAL 13 - 169 CL01 RT1P 10-16 2.5 20
10 15.5 14.8 GPS1MHAM 16 - 208 CL02 RT1S 14.5-18 2.5 20
11 17.6 17 GPS1MHAN 20 - 260 CL25 RT1S 14.5-18 2.5 20
15 23 22 GPS1MHAP 25 - 325 CL25 RT1U 21-26 4 20
18.5 28.5 27 GPS1MHAR 32 - 416 CL04 RT1V 25-32 6 20
11 17.6 17 GPS2MHAN 20 - 260 CL04 RT1S 14.5-18 2.5 20
A 15
18.5
23
28.5
22
27
GPS2MHAP
GPS2MHAR
25
32
-
-
325
416
CL04
CL04
RT1U
RT1V
21-26
25-32
4
6
20
20
22 33 31.5 GPS2MHAS 40 - 520 CL45 RT2E 30-43 6/10 20
30 45 43 GPS2MHAT 50 - 650 CL06 RT2G 42-55 10 25
B 37
45
53
-
52
62
GPS2MHAU
FDN36MC080GD
63
80
-
800 - 1200
820
1000
CL07
CL08
RT2G
RT2H
42-55
54 – 65
16
16
25
30
45 65 - FDN36MC080GD 80 800 - 1200 1000 CL08 RT2J 64 – 82 25 30
55 80 76 FDN36MC100GD 100 1000 - 150 1200 CL09 RT2J 64 – 82 25 30

C
Surion GPS-M and Record Plus: Coordination Type 2 50kA at 500 and 525V
MOTOR (1) BREAKER CONTACTOR OVERLOAD RELAY
D Rated Rated current Cat. no. Rated Magnetic Magnetic Series Series Setting Smallest Min
power (A) current setting Im current range wire Cu frontal
In Pick-up band (PVC) (2) safety
± 20% Im 380/415V clearance
E (kW)
0.06
500V
0.17
525V
0.16 GPS1MS/HAB
(A)
0.25
(A)
-
(A)
3.2 CL00 RT1B 0.16-0.26
(mm )
1
2
(mm)
20
0.09 0.24 0.22 GPS1MS/HAB 0.25 - 3.2 CL00 RT1B 0.16-0.26 1 20
0.12 0.33 0.3 GPS1MS/HAC 0.4 - 5.2 CL00 RT1C 0.25-0.41 1 20

F 0.18
0.25
0.48
-
0.46
0.64
GPS1MS/HAD
GPS1MS/HAE
0.63
1
-
-
8.2
13
CL00
CL00
RT1D
RT1D
0.4-0.65
0.4-0.65
1
1
20
20
0.25 0.66 - GPS1MS/HAE 1 - 13 CL00 RT1F 0.65-1.1 1 20
0.37 0.9 0.85 GPS1MS/HAE 1 - 13 CL00 RT1F 0.65-1.1 1 20
0.55 1.2 1.15 GPS1MS/HAF 1.6 - 20.5 CL00 RT1G 1.0-1.5 1 20
G 0.75 1.5 1.45 GPS1MS/HAF 1.6 - 20.5 CL00 RT1H 1.3-1.9 1 20
1.1 2.1 1.9 GPS1MS/HAG 2.5 - 32.5 CL01 RT1J 1.8-2.7 1 20
1.5 2.8 2.6 GPS1MS/HAH 4 - 52 CL25 RT1K 2.5-4 1 20
2.2 3.9 3.6 GPS1MS/HAH 4 - 52 CL25 RT1K 2.5-4 1 20
H 3 5.3 5 GPS1MS/HAJ 6.3 - 82 CL25 RT1L 4.0-6.3 1 20
4 6.8 6.5 GPS1MHAK 10 - 130 CL25 RT1M 5.5-8.5 1 20
5.5 9.1 8.6 GPS1MHAK 10 - 130 CL25 RT1N 8.0-12 1.5 20
7.5 12 11.4 GPS1MHAL 13 - 169 CL25 RT1P 10-16 2.5 20
I 10 15.5 14.8 GPS1MHAM 16 - 208 CL25 RT1S 14.5-18 2.5 20
11 17.6 17 GPS1MHAN 20 - 260 CL25 RT1S 14.5-18 2.5 20
15 23 22 GPS1MHAP 25 - 325 CL04 RT1U 21-26 4 20
18.5 28.5 27 GPS1MHAR 32 - 416 CL04 RT1V 25-32 6 20
X 11 17.6
23
17
22
GPS2MHAN 20 - 260 CL04 RT1S 14.5-18 2.5 20
15 GPS2MHAP 25 - 325 CL04 RT1U 21-26 4 20
18.5 28.5 27 GPS2MHAR 32 - 416 CL45 RT1V 25-32 6 20
22 33 31.5 GPS2MHAS 40 - 520 CL06 RT2E 30-43 6/10 25
30 45 43 GPS2MHAT 50 - 650 CL06 RT2G 42-55 10 25
37 53 52 GPS2MHAU 63 - 820 CL07 RT2G 42-55 16 25
45 - 62 FDN36MC080GD 80 800 - 1200 1000 CL09 RT2H 54 – 65 16 30
45 65 - FDN36MC080GD 80 800 - 1200 1000 CL09 RT2J 64 – 82 25 30
55 80 76 FDN36MC100GD 100 1000 - 1500 1200 CL10 RT2J 64 – 82 25 30

D.10
Surion
Surion GPS-B and Record Plus: Coordination Type 2 65kA at 380/400V and 415V
MOTOR MOTOR PROTECTION CIRCUITBREAKER CONTACTOR THERMAL RELAY

Rated Ie (A) Ie (A) Cat. no. Setting Magnetic Series Class 10


power range In setting Im

(kW) 380/400V 415V (A) (A) (A)


0.25 0.9 0.8 GPS1BHAE 0.63-1 13 CL00 Integrated into the motor protection circuit breaker
0.37 1.25 1.1 GPS1BHAF 1-1.6 20.5 CL00 Integrated into the motor protection circuit breaker
0.55 1.6 1.5 GPS1BHAF 1-1.6 20.5 CL00 Integrated into the motor protection circuit breaker
0.75 2 1.9 GPS1BHAG 1.6-2.5 32.5 CL00 Integrated into the motor protection circuit breaker

1.1 2.6 2.5 GPS1BHAH 2.5-4 52 CL25 Integrated into the motor protection circuit breaker
1.5 3.5 3.45 GPS1BHAH 2.5-4 52 CL25 Integrated into the motor protection circuit breaker
2.2 5 4.7 GPS1BHAJ 4-6.3 82 CL25 Integrated into the motor protection circuit breaker

Technical data
3 7 6.5 GPS1BHAK 6.3-10 130 CL25 Integrated into the motor protection circuit breaker
4 9 8 GPS1BHAK 6.3-10 130 CL25 Integrated into the motor protection circuit breaker
5.5 12 11 GPS1BHAL 9.0-13 169 CL25 Integrated into the motor protection circuit breaker
7.5 16 14 GPS1BHAM 11.0-16 208 CL25 Integrated into the motor protection circuit breaker
11 22.5 21 GPS1BHAP 19-25 325 CL25 Integrated into the motor protection circuit breaker

15 30 28 GPS1BHAR 24-32 416 CL04 Integrated into the motor protection circuit breaker
18.5 37 35 GPS2BHAS 28-40 520 CL45 Integrated into the motor protection circuit breaker

22 44 41 GPS2BHAT 25-50 650 CL06 Integrated into the motor protection circuit breaker
30 60 55 GPS2BHAU 45-63 820 CL07 Integrated into the motor protection circuit breaker

37 72.5 65 FDH36MC080 80 950 CL08 RT2J (64-82A)


45 85 79 FDH36MC100 100 1140 CL09 RT2L (78-97A) A

Surion GPS-B and Record Plus: Coordination Type 2 80kA at 380/400V and 415V
B
MOTOR MOTOR PROTECTION CIRCUITBREAKER CONTACTOR THERMAL RELAY

Rated Ie (A) Ie (A) Cat. no. Setting Magnetic Series Class 10


power range In setting Im
C
(kW) 380/400V 415V (A) (A) (A)
0.25 0.9 0.8 GPS1BHAE 0.63-1 13 CL00 Integrated into the motor protection circuit breaker
0.37 1.25 1.1 GPS1BHAF 1-1.6 20.5 CL00 Integrated into the motor protection circuit breaker
0.55
0.75
1.6
2
1.5
1.9
GPS1BHAF
GPS1BHAG
1-1.6
1.6-2.5
20.5
32.5
CL00
CL00
Integrated into the motor protection circuit breaker
Integrated into the motor protection circuit breaker
D
1.1 2.6 2.5 GPS1BHAH 2.5-4 52 CL25 Integrated into the motor protection circuit breaker
1.5
2.2
3.5
5
3.45
4.7
GPS1BHAH
GPS1BHAJ
2.5-4
4-6.3
52
82
CL25
CL25
Integrated into the motor protection circuit breaker
Integrated into the motor protection circuit breaker
E
3 7 6.5 GPS1BHAK 6.3-10 130 CL25 Integrated into the motor protection circuit breaker
4 9 8 GPS1BHAK 6.3-10 130 CL25 Integrated into the motor protection circuit breaker
5.5 12 11 GPS1BHAL 9.0-13 169 CL05 Integrated into the motor protection circuit breaker F
7.5 16 14 FDH36MC020 20 210 CL04 RT1S (14.5-18A)
11 22.5 21 FDH36MC030 30 300 CL45 RT1U (21-26A)

15 30 28 FDH36MC030 30 450 CL45 RT1V (25-32A) G


18.5 37 35 FDH36MC050 50 500 CL45 RT1W (30-40A)

22 44 41 FDH36MC050 50 580 CL06 RT2G (42-55A)


30 66 55 FDH36MC080 80 800 CL07 RT2H (54-65A) H
37 72.5 65 FDH36MC080 80 950 CL08 RT2J (64-82A)
45 85 79 FDH36MC100 100 1140 CL09 RT2L (78-97A)
I

(1) Current are relevant to four pole motors not having special characteristics of torque. Inrush currents: H 8 time rated current for H 1s.
(2) The minimum cycle cross-sections are referred to an ambient temperature of 30ºC max. in free air and are selected to withstand the maximum let-through
energy and the motor rated current. Besides the user has to consider the drop voltage, the type of laying and ambient temperature.

D.11
Surion
Record Plus: Coordination Type 2 150kA at 380/400V and 415V (Class 10 protection)
MOTOR (1) THERMAL-MAGNETIC CIRCUIT BREAKER CONTACTOR

Rated Rated current Cat. no. (3) Magnetic Magnetic Thermal Thermal Series Smallest Min
power (A) setting Im current setting setpoint wire frontal
pick-up range (400V) Cu safety
band Setpoint (PVC) (2) clearance
± 20% Im 380/415V

(kW) 380/400V 415V (A) (A) (A) (A) (mm2) (mm)


7.5 16 14 FD*36TD016ED 160 160 12.8 - 16 16 CL45 2.5 20
11 22.5 21 FD*36TD025ED 250 250 20 – 25 22.5 CL45 4 20
Manual motorstarter

15 30 28 FD*36TD032ED 320 320 26 – 32 30 CL45 6 20


18.5 37 35 FD*36TD040ED 400 400 32 – 40 37 CL45 10 20
22 44 40 FD*36TD050ED 500 500 40 – 50 40 CL06 10 25
30 60 55 FD*36TD063ED 630 630 50 – 63 55 CL07 16 25
37 72 68 FD*36TD080GD 800 800 64 – 80 68 CL08 25 25
45 85 80 FD*36TD100GD 1000 1000 80 – 100 80 CL09 35 30
55 105 100 FD*36TD125GD 1250 1250 100 – 125 100 CL10 35 30
75 138 135 FD*36TD160GD 1280 1280 128 – 160 135 CK75 50 40
90 170 165 FE*36TD200KF 1000 – 2000 1700 160 – 200 165 CK08 70 40
110 211 200 FE*36TD250KF 1250 – 2500 2100 200 – 250 200 CK85 95 40
132 245 240 FE*36TD250KF 1250 – 2500 2500 200 - 250 240 CK09 120 40
(*) Max Iq rating in kA: type N = 50 kA, type H = 80 kA, type L = 150 kA.

(1) Current are relevant to four pole motors not having special characteristics of torque.
Inrush currents: H 8 times rated current for H 1s (Normal starting) or H 5s (Heavy starting).
(2) The minimum cycle cross-sections are referred to an ambient temperature of 30ºC max. in free air and are selected to withstand the maximum let-through
energy and the motor rated current. Besides the user has to consider the drop voltage, the type of laying and ambient temperature.
(3) Foreseen values for E-frame.
A

D.12
Surion
Record Plus: Coordination Type 2 Up to 150kA at 380/400V and 415V (Class 10 protection)
MOTOR (1) ONLY MAGNETIC CIRCUIT BREAKER CONTACTOR OVERLOAD RELAY
Rated Rated current Cat. no. (3) Magnetic Magnetic Series Series Setting Smallest Min
power (A) setting Im current range wire frontal
pick-up Cu safety
band Setpoint (PVC) (2) clearance
± 20% Im 380/415V

(kW) 380/400V 415V (A) (A) (A) (mm2) (mm)


4 9 8 FD*36MC012ED 125 - 188 120 CL04 RT1N 8 - 12 1.5 20
5.5 12 11 FD*36MC012ED 125 - 188 150 CL04 RT1P 10 - 16 2.5 20
7.5 - 14 FD*36MC020ED 200 - 300 200 CL04 RT1P 10 - 16 2.5 20
7.5 16 - FD*36MC020ED 200 - 300 210 CL04 RT1S 14.5 - 18 2.5 20
11 22.5 21 FD*36MC030ED 300 - 450 450 CL45 RT1U 21 - 26 4 20
15 30 28 FD*36MC030ED 300 - 450 500 CL45 RT1V 25 - 32 6 20

Technical data
18.5 37 35 FD*36MC050ED 500 - 750 500 CL45 RT1W 30 - 40 10 20
22 - 40 FD*36MC050ED 500 - 750 540 CL06 RT2E 30 - 43 10 25
22 44 - FD*36MC050ED 500 - 750 580 CL06 RT2G 42 - 55 10 25
30 60 55 FD*36MC080GD 800 - 1200 800 CL07 RT2H 54 - 65 16 25
37 72 68 FD*36MC080GD 800 - 1200 950 CL08 RT2J 64 - 82 25 25
45 85 80 FD*36MC100GD 1000 - 1500 1140 CL09 RT2L 78 - 97 35 30
55 - 100 FD*36MC100GD 1000 - 1500 1400 CL10 RT2M 90 - 110 35 30
55 105 - FE*36MC160JF 1600 - 2400 1400 CL10 RT2M 90 - 110 35 30
75 138 135 FE*36MC160JF 1600 - 2400 1900 CK75 RT3E 110 - 140 50 40
90 170 165 FE*36MC250KF 2500 - 3750 2500 CK08 RT3F 140 - 190 70 40
110 211 200 FE*36MC250KF 2500 - 3750 2800 CK85 RT4P 175 - 280 95 40
132 245 240 FE*36MC250KF 2500 - 3750 3150 CK09 RT4P 175 - 280 120 40

A
Record Plus: Coordination Type 2 Up to 150kA at 380/400V and 415V (Class 30 protection)
MOTOR (1) ONLY MAGNETIC CIRCUIT BREAKER CONTACTOR OVERLOAD RELAY

Rated Rated current Cat. no. (3) Magnetic Magnetic Series Series Setting Smallest Min B
power (A) setting Im current range wire frontal
pick-up Cu safety
band Setpoint (PVC) (2) clearance
± 20% Im 380/415V
C
(kW) 380/400V 415V (A) (A) (A) (mm2) (mm)
2.2 5 4.5 FD*36MC008ED 80 - 120 80 CL25 RT4LB 4 - 6.5 1.5 20
3 7 6.5 FD*36MC008ED 80 - 120 90 CL04 RT4LC 5.5 - 8.5 1.5 20
4 9 8 FD*36MC012ED 125 - 188 120 CL04 RT4aLD 7.5 - 11 1.5 20 D
5.5 12 11 FD*36MCa012ED 125 - 188 150 CL45 RT4LE 10 - 16 2.5 20
7.5 - 14 FD*36MC020EaD 200 - 300 200 CL45 RT4LE 10 - 16 2.5 20
7.5 16 - FD*36MC020ED 200 - 300 210 CL45 RT4LF 12.5 - 20 2.5 20
11
15
22.5
30
21
28
FD*36MC030ED
FD*36MC030ED
300 - 450
300 - 450
450
500
CL45
CL45
RT4LG
RT4LH
17 - 27
26 - 40
4
6
20
20
E
18.5 37 35 FD*36MC050ED 500 - 750 500 CL06 RT4LH 26 - 40 10 25
22 - 40 FD*36MC050ED 500 - 750 540 CL06 RT4LJ 32 - 52 10 25
22
30
44
60
-
55
FD*36MC050ED
FD*36MC080GD
500 - 750
800 - 1200
580
800
CL06
CL07
RT4LJ
RT4LK
32 - 52
45 - 70
10
16
25
25
F
37 72 68 FD*36MC080GD 800 - 1200 950 CL08 RT4LL 60 - 90 25 25
45 85 80 FD*36MC100GD 1000 - 1500 1140 CL09 RT4LL 60 - 90 35 30
55 - 100 FD*36MC100GD 1000 - 1500 1400 CL10 RT4LM 80 - 125 35 30
55 105 - FE*36MC160JF 1600 - 2400 1400 CL10 RT4LM 80 - 125 35 30 G
75 138 135 FE*36MC160JF 1600 - 2400 1900 CK75 RT4LN 120 - 190 50 40a
90 170 165 FE*36MC250KF 2500 - 3750 2500 CK08 RT4LN 120 - 190 70 40
110 211 200 FE*36MC250KF 2500 - 3750 2800 CK85 RT4LR 200 - 310 95 40
132 245 240 FE*36MC250KF 2500 - 3750 3150 CK09 RT4LR 200 - 310 120 40 H
(*) Max Iq rating in kA: type N = 50 kA, type H = 80 kA, type L = 150 kA.

(1) Current are relevant to four pole motors not having special characteristics of torque.
Inrush currents: H 8 times rated current for H 1s (Normal starting) or H 5s (Heavy starting).
(2) The minimum cycle cross-sections are referred to an ambient temperature of 30ºC max. in free air and are selected to withstand the maximum let-through
I
energy and the motor rated current. Besides the user has to consider the drop voltage, the type of laying and ambient temperature.
(3) Foreseen values for E-frame.

D.13
Surion
Dimensional drawings
Fuseless starter - GPS1 rocker + Minicontactor MC
Manual motorstarter

B MC...A MC...C

C
Fuseless starter - GPS1 rocker + Contactor CL00-CL01-CL02
D

CL00A-CL01A-CL02A CL00D-CL01D-CL02D

D.14
Surion

Fuseless starter - GPS1 rocker + Contactor CL25

Dimensions
A

CL25A CL25D
B

C
Fuseless starter - GPS2 + Contactor CL03-CL04
D

CL03A-CL04A CL03D-CL04D

D.15
Surion
Dimensional drawings
Fuseless starter - GPS2 + Contactor CL45
Manual motorstarter

B
CL45A CL45D

C
Fuseless starter - GPS2 + Contactor CL06-CL08
D

CL06A-CL08A

D.16
Surion

Fuseless starter - Record Plus + Contactor CL09 + Thermal overload relay RT2

Dimensions
A

D.17
Series M, CL, CK
Direct-on-line starters

Series M
6 to 12A (AC-3)
• Power circuit: up to 690V AC
• Control circuit: up to 600V AC
• Polycarbonate enclosure (IP40 - IP65)
- Shock resistance
- Total insulation §
- 4 knock-out input holes PG13.5
- Cable entry in the base
Motorstarters

• Terminals protected against accidental contact


• 16 setting ranges from 0.11 up to 14A
• Start contact block
Order codes ! page D.19
Wiring diagrams ! page D.24
Dimensions ! page D.32

Series CL
9 to 105A (AC-3)
A
• Power circuit: up to 690V AC
• Control circuit: up to 690V AC
• IP00 version
B • Polycarbonate enclosure (IP40 - IP65)
- Shock resistance
- Total insulation §
C - 4 knock-out input holes
• Empty enclosures version
• Start contact block

E Order codes ! page D.19


Wiring diagrams ! page D.25
Dimensions ! page D.32

F
Series CK
150 to 825A (AC-3)
G
• Power circuit: up to 1000V AC
• Control circuit: up to 690V AC
H • Protection degree IP00
• Terminals protected against accidental contact: IP20
- KG75 to KG12: Coil and auxiliary terminals with built-in protection
Main terminals protector on request
I - KG13: Coil and auxiliary terminals with built-in protection

Order codes ! page D.19


Wiring diagrams ! page D.26
Dimensions ! page D.33

D.18
Series M, CL, CK
Series M - Direct-on-line starters
Push-buttons Protection Cat. no. Ref. no Pack
degree
Empty boxes Start/Stop + Reset IP40 MG0004PAT0 209780 1
IP65 MG0006PAT0 209781 1
Reset only IP40 MG0004RAT0 137567 1
IP65 MG0006RAT0 116402 1
Start/Emergency stop IP40 MG0004QAT0 137566 1
IP65 MG0006QAT0 116074 1

Start contact block

Direct-on-line starters
Laterally mounted to the contactor, allowing the electrical operation MAGL110AT 100608 1
the box push-button which incises on it.

Series CL - Direct-on-line starters


For use with Push-buttons Protection Cat. no. Ref. no Pack
degree
Empty boxes CL00, CL01,CL02 Start/Stop + Reset IP40 LG0004P1B0 209344 1
IP65 LG0006P1B0 200004 1
Without push-buttons IP40 LG0004S1B0 209347 1
IP65 LG0006S1B0 116011 1
Only Reset IP40 LG0004R1B0 116651 1
IP65 LG0006R1B0 116652 1
CL25 Start/Stop + Reset IP40 LG2504P1B0 100885 1
IP65 LG2506P1B0 101095 1
Only Reset IP40 LG2504R1B0 116226 1
IP65 LG2506R1B0 133611 1
CL04 Start/Stop + Reset IP40 LG0404P1B0 116653 1
IP65 LG0406P1B0 116656 1
Only Reset IP40 LG0404R1B0 133264 1 A
IP65 LG0406R1B0 133265 1
CL25, CL04 Without push-buttons IP40 LG0404S1B0 116996 1
IP65 LG0406S1B0 116997 1

B
Neutral terminal BNL 104797 10

Conversion to permanent Pressure-fixed between push-buttons in direct-on-line enclosures EPL 104798 10


control for mechanical interlocking into permanent control. D

Start contact block Pressure-fixed onto the front of direct-on-line starters allowing electrical BMLF 104800 10
operation using the start push-button on the enclosure F

Series CK - Direct-on-line starters. IP00 H


Cat. no. Ref. no. Pack
Connection sets Busbar set for power circuit CK85,CK09,CK95 KVP85G 104770 1
CK10,CK11 KVP10G 104771 1
CK12 KVP12G 104767 1
I
Plate Metallic plate CK85, CK09, CK95 PVP85G 241747 1
CK10, CK11 PVP10G 241748 1
CK12 PCP12G 241749 1
X

D.19
Series M, CL, CK
Reversing starters

Series M
6 to 12A (AC-3)
• Power circuit: up to 690V AC
• Control circuit: up to 600V AC
up to 250V DC
• Assembled versions on request.
• Screw and push-on terminals protected against accidental contact.
• Protection degree IP20 in accordance with EN 60529.
• Facility to mount instant and timed auxiliary contact blocks and voltage
Motorstarters

suppressor blocks.

Order codes ! page D.21


Wiring diagrams ! page D.28
Dimensions ! page D.34

Series CL
9 to 105A (AC-3)
A
• Power circuit: up to 690V AC
• Control circuit: up to 690V AC
• Protection degree IP00
B

Order codes ! page D.21


E Wiring diagrams ! page D.28
Dimensions ! page D.34

F
Series CK
150 to 825A (AC-3)
G
• Power circuit: up to 1000V AC
• Control circuit: up to 660V AC
• Protection degree IP00
H

Order codes ! page D.21


Wiring diagrams ! page D.29
Dimensions ! page D.35

D.20
Series M, CL, CK
Series M and CL - Reversing starters
Description For use with ac/dc Cat. no. Ref. no. Pack.
contactor
Wiring kits Suitable to be usd with link MC0.., MC1.., MC2.. ac/dc WKMIU 101421 1
for reversing modules CL00.., CL01.., CL02.. ac/dc WKLI02P 101422 1
starters Upper and lower connections CL25.. ac/dc WKLI25P 101423 1
without overload relays CL03.., CL04... ac/dc WKLI04P 101424 1
CL45.. ac/dc WKLI45P 101425 1
CL06A.., CL07A. ac WKLI07P 101426 1

Plate Metallic plate CL06, CL07, CL08 WKI0910 241751 1


CL08, CL09, CL10 WKI0608 241752 1

Reversing starters
Series CK - Reversing starters. IP00
Description For use with Cat. no. Ref. no. Pack.
contactor
Connection sets Busbar set for power circuit KI75, KI08 KVP75U 113627 1
KI85, KI09, KI95 KVP85U 113628 1
KI10, KI11 KVP10U 133374 1
KI12 KVP12U 113630 1
Busbar set for power circuit KI75, KI08 KVP75I 133370 1
For assembly KI85, KI09, KI95 KVP85I 113631 1
with thermal overload relay. KI10, KI11 KVP10I 133371 1
KI12 KVP12I 113633 1

Plate Metallic plate CK75, CK08


CK85, CK95
KVB75I
KVB95I
104690
104691
1
1
A
CK10, CK11 KVB10I 104692 1
CK12 KVB12I 104693 1

D.21
Series CL, CK
Star-delta starters

Series CL
• Power circuit: up to 1000V AC
• Control circuit: up to 690V AC
• Protection degree IP00
• Use delay setting by electronic relay NMET
• Terminals protected against accidental contact
Motorstarters

Order codes ! page D.23


Wiring diagrams ! page D.30
Dimensions ! page D.37

Series CK
• Power circuit: up to 1000V AC
A • Control circuit: up to 690V AC
• Protection degree IP00
• Protection against accidental contacts: IP20
B - KE75: Built-in protection
- KE08 - KE12: Coil and auxiliary terminals with built-in protection
Main terminals protector on request
- KE13: Coil and auxiliary terminals with built-in protection
C

Order codes ! page D.23


E Wiring diagrams ! page D.30
Dimensions ! page D.37

D.22
Series CL, CK
Series CL - Star-delta starters
Line-delta Cat. no. Ref. no. Pack
contactor
Busbar sets for power CL00 WKLE00 103238 1
circuit CL01, CL02 WKLE02 103241 1
CL25 WKLE25 103243 1

Plate Metallic plate CL06, CL07, CL08 WLSD 103247 1


CL09, CL10 WLSD1 241750 1

Star-delta starters
Series CK - Star-delta starters. IP00
Line-delta Star Cat. no. Ref. no. Pack
contactor contactor
Busbar sets for power CK75, CK08 CK75, CK08 KVP75E 133378 1
circuit CK85, CK09, CK95 CK75, CK08 KVP08E 116212 1
CK95 CK85, CK09, CK95 KVP85E 133379 1
CK10, CK11 CK85, CK09, CK95 KVP95E 113637 1
CK10, CK11 CK10, CK11 KVP10E 133380 1
CK12 CK10, CK11 KVP12E 116235 1

Plate Metallic plate CK75, CK08 KVB75E 104694 1


CK85, CK95 KVB95E 104695 1
CK10, CK11 KVB10E 104597 1
CK12 KVB12E 104587 1

D.23
Series M, CL
Wiring diagrams

Series M. Direct-on-line starter with


reset
Power circuit Control circuit Control by two or more push-buttons
Use of two phases
(single phase) Three phase
Motorstarters

Series M. Direct-on-line starter with


A start/emergency stop push-button
Power circuit Control circuit Control by two or more push-buttons
B Use of two phases
Three phase
(single phase)

D.24
Series M, CL
Series CL. Direct-on-line starter
Power circuit Control circuit Control by two or more push-buttons

Direct-on-line starters
Control by permanent contact

(float, thermostat, pressure switch, ...)

Series CL. Direct-on-line starter


with reset push-button
Power circuit Control circuit Control by two or more push-buttons

Single phase Three phase


A

(connection K1-95 must be removed)


B
Control by permanent contact
C

(float, thermostat, pressure switch, ...) D

Series CL. Direct-on-line starter E


with start/stop/reset push-button
Power circuit Control circuit Control by two or more push-buttons F
Single phase Three phase

(connection 95-13 must be removed)


H
Control by permanent contact

I
(float, thermostat, pressure switch, ...)
X

D.25
Series CK
Wiring diagrams

Series CK. Direct-on-line starter


Power circuit Control circuit Control by two or more push-buttons
Use of two phases Three phase
(single phase) KG75 ... KG12

Control by permanent contact


Motorstarters

(float, thermostat, pressure switch, ...)

KG13

D.26
Series CK
Notes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Direct-on-line starters
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

D.27
Series M, CL, CK
Wiring diagrams

Series M. Reversing starter without


thermal overload relay
Power circuit Control circuit Control by two or more push-buttons
Motorstarters

Series CL. Reversing starter without


A thermal overload relay
Power circuit Control circuit Control by two or more push-buttons
B

F
Series CL. Reversing starter with
G thermal overload relay
Power circuit Control circuit Control by two or more push-buttons
H

D.28
Series CK
Series CK. Reversing starter
without thermal overload relay
Power circuit Control circuit

KI75 ... KI12 KI13

Reversing starters
Control by two or more push-buttons

Series CK. Direct-on-line starters C


with thermal overload relay
Power circuit Control circuit D
KI75 ... KI12 KI13
E

Control by two or more push-buttons


I

D.29
Series CL, CK
Wiring diagrams

Star-delta starters
Power circuit Control circuit
Motorstarters

D.30
Series CL, CK
Notes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Star-delta starters
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

D.31
Series M, CL, CK
Dimensional drawings
Direct-on-line starters. IP40 / IP65
Series M Series CL

.
Motorstarters

LG00... - LG02... LG25... - LG04...


A 87 101
B 180 195
C 124.5 136
D 162 177
E 20 23

A F
G
49
8
57
8
ØH 21 23
ØJ 21 21
ØK 21 23
B ØL 21 23

C
Series CL - Direct-on-line starters
LG00_0SB ... LG25_0SB LG04_0S
D

. .
E . .

LG45_0S ... LG08_0S LG09_0S ... LG10_0S


H

I
.
.

. .

D.32
Series M, CL, CK

Series CK - Direct-on-line starters


KG75_0S ... KG08_0S KG85_0S ... KG95_0S

Direct-on-line starters
.
.

.
.

A
KG10_0S ... KG11_0S KG12_0S

D.33
Series M, CL, CK
Dimensional drawings
Series M. Direct-on-line reversing starters
MI_S00SAT_ MJ_S00SAT_
MI_S00SAU_ MJ_S00SAT_

.
.
. .
Motorstarters

MI_S00SAI_ MJ_S00SAI_
MI_S00SAJ_ MJ_S00SAJ_
. . . . . . . .
. . . . . . . . . . . .

.
A
Series CL. Direct-on-line reversing starters without thermal overload relay
B
A B C D Ø A B C D E
LI00... - LI25... 130 116 87.5 81 5.5 LI06... - LI08... 171 135 160 155 133
LI03... - LI45... 150 136 100.5 87 5.5 LI09... - LI10... 186 150 167 155 133
C

G Series CL. Direct-on-line reversing starters with thermal overload relay


A B C D E Ø A B C D E F
LI00... - LI25... 130 116 110.5 81 135 5.5 LI06... - LI08... 171 135 160 155 133 205
H LI03... - LI45... 150 136 103.5 87 145 5.5 LI09... - LI10... 186 150 167 155 133 258

D.34
Series M, CL, CK

Series CK. Direct-on-line reversing starters without thermal overload relay


KI75 .... KI08
.

Reversing starters
. .

KI85 .... KI95

Series CK. Direct-on-line reversing starters with thermal overload relay B


KI75 .... KI08
.
C

E
. .

F
KI85 .... KI95
G

D.35
Series CL, CK
Dimensional drawings
Series CK - Direct-on-line reversing starters without thermal overload relay
KI10 .... KI11
Motorstarters

KI12

Series CK - Direct-on-line reversing starters with thermal overload relay


C
KI10 .... KI11

H KI12

D.36
Series CL, CK

D.O.L. reversing/Star-delta starters


Series CL - Star-delta starters

A B C D
LE00... - LE25... 190 180 110.5 135
LE03... - LE04... 220 210 103.5 145

A B C D E F
LE06... - LE08... 253 217 129 205 155 133
LE09... 263 247 138 247 155 133
LE10... 283 247 151 247 155 133

B
Series CK - Star-delta starters
C
KE75 ... KE08
.

G
KE85 ... KE95

D.37
Series M, CL, CK
Dimensional drawings
Series CK - Star-delta starters
KE10 ... KE11
Motorstarters

KE12
A

D.38
Series M, CL, CK
Utilisation categories Making and breaking capacity
according to IEC 947-4-1
IEC 947-4-1
Standard utilisation categories AC Values given for closing and opening by intermittent use
Category Typical applications Cat. Rated Closing (3) Opening
AC-1 Non-inductive or slightly loads. current Ic/Ie Ur/Ue cosϕ(4) Ic/Ie Ur/Ue cosϕ (4)
Resistance furnaces
AC-1 All 1.5 1.05 0.80 1.5 1.05 0.80
AC-2 Slip-ring motors:
values
starting, plugging
AC-3 Squirrel-cage motors (1): AC-2 All 4 1.05 0.65 4 1.05 0.65
starting, switching off motors during running. values
AC-4 Squirrel-cage motors: AC-3 Ie ≤ 100A 10 1.05 0.45 8 1.05 0.45
starting, plugging, inching. Ie > 100A 10 1.05 0.35 8 1.05 0.35
AC-5 a Discharge lamps
AC-4 Ie ≤ 100A 12 1.05 0.45 10 1.05 0.45
AC-5 b Incandescent lamps
AC-6 a Transformers Ie > 100A 12 1.05 0.35 10 1.05 0.35

Applications
AC-6 b Cos ϕ capacitors
AC-7 a Slightly inductive loads for domestic applications
AC-7 b Motors in domestic applications Cat. Rated Closing Opening
AC-8 a Drive motors for cooling compressors (2) with
current Ic/Ie Ur/Ue L/R(5) Ic/Ie Ur/Ue L/R(5)
manual reset and thermal overload relay
(ms) (ms)
AC-8 b Drive motors for cooling compressors (2) with
manual reset and automatic reset DC-1 All 1.5 1.05 1 1.5 1.05 1
values
DC-3 All 4 1.05 2.5 4 1.05 2.5
Standard utilisation categories DC values
Category Typical applications DC-5 All 4 1.05 15 4 1.05 15
DC-1 Non-inductive or slightly inductive loads. values
A
Resistance furnaces
DC-3 Shunt motors:
starting, plugging, inching
DC-5 Series motors: Electrical endurance B
starting, plugging, inching
DC-6 Incandescent lamps
IEC 947-4-1
Values given for closing and opening intermittent use C
Cat. Rated Closing (3) Opening
current Ic/Ie Ur/Ue cosϕ(4) Ic/Ie Ur/Ue cosϕ(4)
AC-1 All 1 1 0.95 1 1 0.95
values D
AC-2 All 2.5 1 0.65 2.5 1 0.65
values
AC-3 Ie ≤ 17A 6 1 0.65 1 0.17 0.65 E
Ie > 17A 6 1 0.35 1 0.17 0.35
AC-4 Ie ≤ 17A 6 1 0.65 6 1 0.65
Ie > 17A 6 1 0.35 6 1 0.35
F
Cat. Rated Closing Opening
current Ic/Ie Ur/Ue L/R(5) Ic/Ie Ur/Ue L/R(5) G
(ms) (ms)
DC-1 All 1 1 1 1 1 1
values
DC-3 All 2.5 1 2 2.5 1 2 H
(1) Category AC-3 can be used for accidental not continuous short
period service, while mounting and testing machines. The number values
of operations shall not be greater than 5 per minute or 10 per 10 DC-5 All 2.5 1 7.5 2.5 1 7.5
minutes.
(2) The drive motor of a hermetic cooling compressor is an assembly of
values
I
a motor and compressor in the same housing, without any axle; the
motor is working in the cooling liquid.
(3) Making conditions in alternating current are expressed by effective Ue Rated operational voltage
value. Moreover the asymmetrical current high value, referred to
cos ϕ, can assume a higher value.
Ie
Ur
Rated operational current
Feed-back voltage
X
(4) Tolerance for cos ϕ = ± 0.05
(5) Tolerance for L/R = ± 15% Ic Current made or broken

D.39
Series M, CL, CK
Utilisation category AC-1
Three pole contactors
Type MC0 MC1 MC2 CL00 CL01 CL02 CL25 CL03 CL04 CL45 CL06 CL07 CL08 CL09 CL10
Max. operat. current 40ºC (A) 20 20 20 25 25 32 45 45 60 60 90 110 110 140 140
at ambient temp. of 55ºC (A) 20 20 20 25 25 32 45 45 60 60 90 110 110 140 140
(for all voltages) 70ºC (A) 16 16 16 20 20 25 32 32 48 48 72 88 88 110 110
Max. operat. power 230/220V (kW) 7.5 7.5 7.5 9.5 9.5 12 17 17 22.5 22.5 30 42 42 53 53
Three-phase 400/380V (kW) 13 13 13 16.5 16.5 22 29 29 39.5 39.5 55 72.5 72.5 92 92
resistors 440/415V (kW) 15 15 13 18 18 23 32 32 43 43 57 79 79 100 100
500V (kW) 17 17 17 21.5 21.5 27.5 39 39 52 52 69 95 95 121 121
690/660V (kW) 22.5 22.5 22.5 28.5 28.5 38 51 51 68.5 68.5 95 125 125 160 160
Cable size (mm2) 2.5 2.5 2.5 4 4 6 10 10 16 16 35 35 35 50 50
Percentage of the max. 120 ops./h (%) 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100
operational current at 300 ops./h (%) 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100
600 ops./h (%) 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100
Motorstarters

1200 ops./h (%) 100 100 100 100 100 100 100 100 100 100 100 100 100 80 80
3000 ops./h (%) 50 50 50 50 50 50 50 50 50 50 50 50 50 40 40

Type CK75C CK08C CK85B CK09B CK95B CK10C CK11C CK12B CK13B
40ºC (A) 250 250 315 315 450 600 700 1000 1250
55ºC (A) 200 200 252 252 382 510 546 736 1125
70ºC (A) 155 155 195 195 300 402 468 680 1060
Max. operat. power 230/220V (kW) 90 90 114 114 170 191 234 289 450
Three-phase 400/380V (kW) 155 155 196 196 310 329 406 500 780
resistors 440/415V (kW) 180 180 227 227 343 329 470 578 904
500V (kW) 200 200 259 259 389 415 533 657 1027
690/660V (kW) 270 270 341 341 537 572 705 867 1354
A 1000V (kW) 400 400 517 517 780 866 1060 1314 2054
Cable size (mm2) 120 120 185 185 2x 2x 2x 2x 2x
(30X5) (30X8) (30X8) (30X10) (30X10)
Percentage of the max. 120 ops./h (%) 100 100 100 100 100 100 100 100 100
B operational current at 300 ops./h (%) 100 100 100 100 100 100 100 100 90
600 ops./h (%) 100 100 100 100 100 80 80 80 70
1200 ops./h (%) 80 80 80 80 80 – – – –
3000 ops./h (%) 40 40 40 40 – – – – –
C
Four pole contactors
Type MC0 MC1 MC2 CL01 CL02 CL03 CL04 CL05 CL07 CL08(1) CL09(2)
Max. operat. current 40ºC (A) 20 20 20 25 32 45 60 90 110 110 140
D at ambient temp. of: 55ºC (A) 20 20 20 25 32 45 60 90 110 110 140
(for all voltages) 70ºC (A) 16 16 16 20 25 32 48 72 88 88 110
Max. operat. power 230/220V (kW) 7.5 7.5 7.5 9.5 12 17 22.5 30 42 42 53
Three-phase 400/380V (kW) 13 13 13 16.5 22 29 39.5 55 72.5 72.5 92
E resistors 440/415V (kW) 15 15 15 18 23 32 43 57 79 79 100
500V (kW) 17 17 17 21.5 27.5 39 52 69 95 95 121
690/660V (kW) 22.5 22.5 22.5 28.5 38 51 68.5 95 125 25 160
Cable size (mm2) 2.5 2.5 2.5 4 6 10 16 35 35 35 50
F Percentage of the max. 120 ops./h
operational current at 300 ops./h
(%)
(%)
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
600 ops./h (%) 100 100 100 100 100 100 100 100 100 100 100
1200 ops./h (%) 100 100 100 100 100 100 100 100 100 100 80
G 3000 ops./h (%) 50 50 50 50 50 50 50 50 50 50 40

Type CK07B CK08B CK09B CK95B CK10C CK11C CK12B CK13B


Max. operat. current 40ºC (A) 200 325 400 500 600 700 1000 1250
H at ambient temp. of:
(for all voltages)
55ºC
70ºC
(A)
(A)
170
140
260
201
320
272
425
335
510
402
546
468
736
680
1125
1060
Max. operat. power 230/220V (kW) 76 123 152 191 228 266 381 476
Three-phase 400/380V (kW) 131 214 263 329 395 460 658 822

I resistors 440/415V
500V
(kW)
(kW)
143
173
233
281
287
346
359
415
431
519
503
606
719
866
898
1082
690/660V (kW) 228 371 457 572 686 800 1143 1428
1000V (kW) – 562 692 866 1039 1212 1732 2165
Cable size (mm2) 95 185 2x 2x 2x 2x 2x 2x
X (25X5) (30X5) (30X8) (30X8) (30X10) (40X10)
Percentage of the max. 120 ops./h (%) 100 100 100 100 100 100 100 100
operational current at 300 ops./h (%) 100 100 100 100 100 100 100 90
600 ops./h (%) 100 100 100 100 80 80 80 70
1200 ops./h (%) 80 80 80 80 – – – –
3000 ops./h (%) 40 40 40 40 – – – –
Increase in maximum operational current (1) Only types (2NO + 2NC)
through connection poles in parallel: (2) Only types (4NO)
– 2 poles in parallel: Ie x 1.8
– 3 poles in parallel: Ie x 2.4
– 4 poles in parallel: Ie x 3.2

D.40
Series M, CL, CK
Utilisation category AC-3
Three pole contactors
Types MC0 MC1 MC2 CL00 CL01 CL02 CL25 CL03 CL04 CL45 CL06 CL07 CL08 CL09 CL10
Operational current Ie (A) 6 9 12 9 12 18 25 25 32 40 50 65 80 95 105
for Ue ≤ 400V
Max. operat. power 230/220V (kW) 1.5 3 3 2.2 3 4 7.5 7.5 9 11 15 18.5 22 25 30
Three-phase motors (HP) 2 4 4 3 4 5.5 10 10 12 15 20 25 30 34 40
50/60Hz 400/380V (kW) 2.2 4 5.5 4 5.5 7.5 12 12 16 18.5 22 30 37 45 55
(HP) 3 5.5 7.3 5.5 7.5 10 16 16 22 25 30 40 50 60 75
440/415V (kW) 2.2 4 5.5 4 5.5 7.5 12 12 16 22 25 37 45 50 55
(HP) 3 5.5 7.3 5.5 7.5 10 16 16 22 30 34 50 60 68 75
500V (kW) 3 4 5.5 5.5 7.5 10 15 15 18.5 25 30 40 45 55 65
(HP) 4 5.5 7.3 7.5 10 13.5 20 20 25 34 40 55 60 75 88
690/660V (kW) 3 4 5.5 5.5 7.5 10 15 15 18.5 30 35 45 45 55 65
(HP) 4 5.5 7.3 7.5 10 13.5 20 20 25 40 48 60 60 75 88
Percentage of the max. 120 ops./h (%) 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100

Applications
operational current at 300 ops./h (%) 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100
600 ops./h (%) 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100
1200 ops./h (%) 100 100 100 100 100 100 100 100 100 100 100 100 100 75 75
3000 ops./h (%) 35 35 35 35 35 35 35 35 35 35 35 35 35 25 25

Type CK75C CK08C CK85B CK09B CK95B CK10C CK11C CK12B CK13B
Operational current Ie (A) 150 185 205 250 309 420 550 700 825
for Ue ≤ 400V
Max. operat. power 230/220V (kW) 45 55 65 75 90 125 160 220 250
Three-phase motors (HP) 60 75 88 100 125 170 220 300 340
50/60Hz 400/380V (kW) 75 90 110 132 160 220 280 375 450
(HP) 100 125 150 180 220 300 380 510 610 A
440/415V (kW) 80 100 125 132 185 230 315 400 450
(HP) 108 135 170 180 250 312 425 540 610
500V (kW) 100 110 132 160 200 300 400 480 500
(HP) 135 150 180 220 270 405 540 650 680 B
690/660V (kW) 100 132 155 200 250 375 450 500 550
(HP) 135 180 205 270 335 510 610 680 750
1000V (kW) 65 100 110 150 200 300 375 450 500

Percentage of the max. 120 ops./h


(HP)
(%)
88
100
135
100
150
100
205
100
270
100
405
100
510
100
610
100
680
100
C
operational current 300 ops./h (%) 100 100 100 100 100 100 100 100 80
600 ops./h (%) 100 100 100 100 100 75 75 75 65
1200 ops./h
3000 ops./h
(%)
(%)
75
25
75
25
75
25
75
25
75









D
Utilisation category AC-4
E
Three pole contactors
Type MC0 MC1 MC2 CL00 CL01 CL02 CL25 CL03 CL04 CL45 CL06 CL07 CL08 CL09 CL10
Operational current Ue ≤ 690V (A) 2.75 3.5 3.5 5 7 8 12 12 16 18.5 23 30 37 44 50
Operational power 230/220V (kW) 0.55 0.75 0.75 1.1 1.5 1.8 3 3 3.7 4 5.5 7.5 10 11 13 F
(200.000 operations) (HP) 0.73 1 1 1.5 2 2.4 4 4 5 5.3 7.3 9.7 13 14.6 17.3
400/380V (kW) 1.1 1.5 1.5 2.2 3 3.7 5.5 5.5 7.5 9 11 15 18.5 22 25
(HP) 1.5 2 2 3 4 5 7.3 7.3 9.7 12 14.6 20 24.6 29.2 33
500V (kW) 1.5 2.2 2.2 3 4 5.5 7.5 7.5 10 11 15 18.5 22 25 30 G
(HP) 2 3 3 4 5.3 7.3 9.7 9.7 13 14.6 20 24.6 29.2 33 40
690/660V (kW) 2.2 3 3 4 5.5 7.5 10 10 11 15 18.5 22 25 30 37
(HP) 3 4 4 5.3 7.3 9.7 13 13 14.6 20 24.6 29.2 33 40 49
Max. operational current ≤ 400V
(35.000 operations)
(A) 6 9 9 9 12 18 25 25 32 40 50 65 80 95 105 H
Max. operational power 400/380V (kW) 2.2 4 4 4 5.5 7.5 11 12 16 18.5 22 30 37 45 55

Type
Operational current Ue ≤ 400V (A)
CK75C
65
CK08C CK85B CK09B CK95B CK10C CK11C
75 90 110 125 150 165
CK12B CK13B
250 350
I
Operational power 230/220V (kW) 18.5 22 25 33 37 45 50 80 110
Three-phase motors (HP) 24.6 29.2 33 44 49 60 66.5 106 146
50/60Hz
(200.000 operations)
400/380V (kW)
(HP)
33
44
40
53
45
60
55
73
63
83.8
80
106
90
119
132
175
165
219
X
500V (kW) 45 50 63 75 90 100 110 225 250
(HP) 60 66.5 83.8 100 119 133 146 300 332
690/660V (kW) 55 63 80 100 110 132 150 250 315
(HP) 73 83.8 106 133 146 175 200 332 419
Max. operational current ≤ 400V (A) 150 185 205 250 309 420 550 700 825
(35.000 operations)
Max. operational power 400/380V (kW) 75 90 110 132 160 220 280 375 450

D.41
Series M, CL, CK
Electrical endurance

Category AC1

Number of
operations
Motorstarters

Currrent Ic = Ie
all voltages

A Category AC2

D
Number of
E operations

Current
F Ic = 2.5 Ie
(Ue ≤ 400V)

G
Rated motor power
(Ic = 2.5 Ie)

D.42
Series M, CL, CK

Category AC3

Number of
operations

Applications
Current
Ic = Ie
(Ue ≤ 400V)
Rated motor power

A
(Ic = Ie)

C
Category AC4
D

Number of
operations E

H
Current
Ic = 6 Ie
(Ue ≤ 400V)
I
Rated motor power
(Ic = 6 Ie)

D.43
Series M, CL, CK
Electrical endurance

Mixed category AC2 / AC’2 Mixed category AC4 / AC3


Graph to determine the coefficient which when multiplied Electrical endurance for mixed category (AC3/
by the contactor electrical endurance in category AC’2, will AC4) is calculated with the following formula:
give the electrical endurance in mixed category AC2/AC’2.

Electrical
Example:
endurance
– % of operations in AC2: Electrical endurance (AC3)
(AC3/AC4) =
35% (or 65% as AC’2) % ops. AC4 Electr. endur. (AC3) _
– Breaking current Ic = 2.54 Ie
1 +
100
X
( Electr. endur. (AC4)
1 )
– Contactor considered: CK08BA
Motorstarters

Resultant coefficient from the graph: 0.35


Electrical endurance in AC’2 for contactor
CK085A , to drive a motor of 45kW at 380V:
le = 85A; 5.5 x 106operations.

Resultant electrical endurance for mixed service


considered:
0.35 x 5.5 x 106 = 1.92 x 106 operations.

D.44
Series M, CL, CK
Notes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Applications
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

D.45
Series M, CL, CK
Series M and CL. Max. operational current Ie (A) - DC utilisation categories
Category DC1. L/R H 1ms
Ue Poles MC0 MC1 MC2 CL00 CL01 CL02 CL25 CL03 CL04 CL45 CL05 CL06 CL07 CL08 CL09 CL10
in serie
24V 1 6 9 9 18 18 18 25 25 32 40 50 50 65 65 80 80
2 8 12 12 25 25 32 45 45 60 60 90 90 110 110 140 140
3 15 20 20 25 25 32 45 45 60 60 90 90 110 110 140 140
4 15 20 20 - 25 32 - 45 60 - 90 - 110 - 140 -
48V 1 5 7.5 7.5 15 15 15 20 20 25 35 45 45 55 55 70 70
2 8 12 12 25 25 32 45 45 60 60 90 90 110 110 140 140
3 12 16 16 25 25 32 45 45 60 60 90 90 110 110 140 140
4 15 20 20 - 25 32 - 45 60 - 90 - 110 - 140 -
60V 1 4 6 6 12 12 12 18 18 18 32 40 40 50 50 65 65
2 6 9 9 25 25 32 45 45 60 60 90 90 110 110 140 140
3 12 16 16 25 25 32 45 45 60 60 90 90 110 110 140 140
4 15 20 20 - 25 32 - 45 60 - 90 - 110 - 140 -
125V 1 1.6 2.5 2.5 6 6 6 8 8 8 8 16 16 16 16 16 16
2 4 6 6 18 18 18 25 25 45 45 80 80 90 90 110 110
3 5 10 10 25 25 25 32 45 60 60 90 90 110 110 140 140
Motorstarters

4 5 10 10 - 25 32 - 45 60 - 90 - 110 - 140 -
220V 1 0.2 0.36 0.36 0.8 0.8 0.8 0.8 1 1 1 2 2 2 2 2 2
2 1.7 2.6 2.6 7.5 7.5 7.5 7.5 8 8 8 20 20 20 20 20 20
3 4 8 8 25 25 25 32 45 50 50 90 90 110 110 140 140
4 4 8 8 - 25 32 - 45 60 - 90 - 110 - 140 -
440V 1 0.09 0.13 0.13 0.4 0.4 0.4 0.4 0.5 0.5 0.5 0.8 0.8 0.8 0.8 0.8 0.8
2 0.26 0.4 0.4 0.8 0.8 0.8 0.8 1 1 1 2 2 2 2 2 2
3 0.5 1 1 8 8 8 10 10 10 10 15 15 15 15 15 15
4 0.5 1 1 - 15 15 - 20 25 - 80 - 90 - 110 -
600V 1 - - - - - - - - - - - - - - - -
2 - - - 0.4 0.4 0.4 0.4 0.5 0.5 0.5 1 1 1 1 1 1
3 - - - 4 4 4 5 5 5 5 7.5 7.5 7.5 7.5 7.5 7.5
4 - - - - 8 10 - 12 12 - 50 - 65 - 75 -

Category DC3. L/R H 2.5ms


A Ue Poles
in serie
MC0 MC1 MC2 CL00 CL01 CL02 CL25 CL03 CL04 CL45 CL05 CL06 CL07 CL08 CL09 CL10

24V 1 - - - 12 12 12 18 18 25 32 40 40 50 50 65 65
2 4 9 9 18 18 18 25 25 40 40 65 65 80 80 105 105
3 8 12 12 18 18 18 25 25 40 40 65 65 80 80 105 105
B 48V
4
1
-
-
-
-
-
-
-
9
18
9
18
9
-
12
25
12
40
18
-
20
65
30
-
30
80
35
-
35
105
45
-
45
2 3 6 6 18 18 18 25 25 40 40 65 65 80 80 105 105
3 6 9 9 18 18 18 25 25 40 40 65 65 80 80 105 105
4 - - - - 18 18 - 25 40 - 65 - 80 - 105 -
60V 1 - - - 7.5 7.5 7.5 10 10 15 15 25 25 30 30 35 35
C 2
3
3
6
6
9
6
9
18
18
18
18
18
18
25
25
25
25
40
40
40
40
65
65
65
65
80
80
80
80
105
105
105
105
4 - - - - 18 18 - 25 40 - 65 - 80 - 105 -
125V 1 - - - 2 2 2 2 3 3 3 3 3 3 3 3 3
2 0.85 4.5 4.5 10 10 12 18 18 25 32 50 50 60 60 80 80
3 1.7 6 6 15 15 18 25 25 32 40 35 35 80 80 105 105
D 220V
4
1
-
-
-
-
-
-
-
0.6
15
0.6
18
0.6
-
0.6
25
0.6
32
0.6
-
0.6
35
0.8
-
0.8
80
0.8
-
0.8
105
0.8
-
0.8
2 0.35 1.2 1.2 2 2 2 2 2 2 2 7 7 7 7 7 7
3 0.7 2.5 2.5 12 12 12 18 18 25 32 50 50 65 65 95 95
4 - - - - 15 18 - 32 32 - 65 - 80 - 105 -
E 440V 1
2
-
0.05
-
0.15
-
0.15
-
0.3
-
0.3
-
0.3
-
0.3
-
0.5
-
0.5
-
0.5
-
1
-
1
-
1
-
1 1
-
1
-

3 0.13 0.3 0.3 1.5 1.5 1.5 1.5 3 3 3 3 3 3 3 3 3


4 - - - - 6 6 - 6 6 - 50 - 65 - 75 -
600V 1 - - - - - - - - - - - - - - - -
2 - - - - - - - - - - - - - - - -
F 3
4
-
-
-
-
-
-
0.8
-
0.8
2.5
0.8
2.5
0.8
-
1.5
2.5
1.5
2.5
1.5
-
1.5
25
1.5
-
1.5
30
1.5
-
1.5
35
1.5
-

Category DC5. L/R H 15ms


Ue Poles MC0 MC1 MC2 CL00 CL01 CL02 CL25 CL03 CL04 CL45 CL05 CL06 CL07 CL08 CL09 CL10
G in serie
24V 1 - - - 12 12 12 18 18 25 32 40 40 50 50 65 65
2 3 4.5 4.5 18 18 18 25 25 40 40 65 65 80 80 105 105
3 6 9 9 18 18 18 25 25 40 40 65 65 80 80 105 105
4 - - - - 18 18 - 25 40 - 65 - 80 - 105 -
H 48V 1
2
-
2.5
-
4
-
4
9
18
9
18
9
18
12
25
12
25
18
40
20
40
30
65
30
65
35
80
35
80
45
105
45
105
3 6.5 8 8 18 18 18 25 25 40 40 65 65 80 80 105 105
4 - - - - 18 18 - 25 40 - 65 - 80 - 105 -
60V 1 - - - 7.5 7.5 7.5 10 10 15 15 25 25 30 30 35 35

I 2
3
2
5
3
7
3
7
18
18
18
18
18
18
25
25
25
25
40
40
40
40
65
65
65
65
80
80
80
80
105
105
105
105
4 - - - - 18 18 - 25 40 - 65 - 80 - 105 -
125V 1 - - - 0.8 0.8 0.8 0.8 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2
2 0.65 1.5 1.5 5 5 5 5 5 5 5 50 50 60 60 85 85
3 1.3 2 2 15 15 15 20 20 25 32 60 60 70 70 95 95
X 220V
4
1
-
-
-
-
-
-
-
-
15
-
18
-
-
-
25
-
32
-
-
-
65
0.5
-
0.5
80
0.5
-
0.5
105
0.5
-
0.5
2 0.16 0.26 0.26 0.8 0.8 0.8 0.8 0.8 0.8 0.8 3 3 3 3 4 4
3 0.5 0.8 0.8 3 3 3 3 3 3 3 7 7 7 7 7 7
4 - - - - 10 10 - 15 15 - 65 - 75 - 95 -
440V 1 - - - - - - - - - - - - - - - -
2 - - - - - - - - - - - - - - - -
3 0.4 0.1 1.1 0.5 0.5 0.5 0.5 0.7 0.7 0.7 1 1 1 1 1 1
4 - - - - 2 2 - 4 4 - 40 - 50 - 60 -
600V 1 - - - - - - - - - - - - - - - -
2 - - - - - - - - - - - - - - - -
3 - - - - - - - - - - - - - - - -
4 - - - - 0.75 0.75 - 2.5 2.5 - 20 - 25 - 30 -

D.46
Series M, CL, CK
Max. operational current Ie (A) - DC utilisation categories (continued)
Category DC1. L/R H 1ms
Ue Poles CK07 CK75 CK08 CK85 CK09 CK95 CK10 CK11 CK12 CK13
in serie
24V 1 150 200 200 250 250 350 500 600 800 1000
2 200 250 250 315 315 450 600 700 1000 1250
3 200 250 250 315 315 450 600 700 1000 1250
4 200 - 250 - 315 450 600 700 1000 1250
48V 1 125 170 170 200 200 295 425 500 600 850
2 140 175 175 220 220 315 425 480 700 850
3 200 250 250 315 315 500 600 700 1000 1250
4 200 - 250 - 315 500 600 700 1000 1250
60V 1 100 140 140 175 175 245 350 420 560 700
2 140 175 175 220 220 315 425 480 700 850
3 200 250 250 315 315 500 600 700 1000 1250
4 200 - 250 - 315 500 600 700 1000 1250
125V 1 20 25 25 30 30 50 60 70 100 125
2 110 200 200 250 250 300 400 500 600 1000
3 200 250 250 315 315 500 600 700 1000 1250
4 200 - 250 - 315 500 600 700 1000 1250

Applications
220V 1 - - - - - - - - - -
2 65 110 110 150 150 200 250 250 300 400
3 200 250 250 315 315 500 600 700 1000 1250
4 200 - 250 - 315 500 600 700 1000 1250
440V 1 - - - - - - - - - -
2 - - - - - - - - - -
3 60 120 120 150 150 180 240 300 400 480
4 110 - 200 - 250 315 400 500 700 800
600V 1 - - - - - - - - - -
2 - - - - - - - - - -
3 32 65 65 80 80 95 130 160 215 250
4 85 - 100 - 130 170 215 265 375 430

Category DC3. L/R H 2.5ms


Ue Poles
in serie
CK07 CK75 CK08 CK85 CK09 CK95 CK10 CK11 CK12 CK13 A
24V 1 105 150 185 205 250 309 420 550 700 825
2 105 150 185 205 250 309 420 550 700 825
3 105 150 185 205 250 309 420 550 700 825

48V
4
1
105
70
-
105
185
130
-
140
250
175
309
215
420
290
550
385
700
490
825
575 B
2 105 150 185 205 250 309 420 550 700 825
3 105 150 185 205 250 309 420 550 700 825
4 105 - 185 - 250 309 420 550 700 825
60V 1 55 85 105 110 140 175 230 300 390 460
2
3
105
105
150
150
185
185
205
205
250
250
309
309
420
420
550
550
700
700
825
825
C
4 105 - 185 - 250 309 420 550 700 825
125V 1 20 25 25 30 30 50 60 70 100 125
2 105 150 185 205 250 309 420 550 700 825
3 105 150 185 205 250 309 420 550 700 825

220V
4
1
105
-
-
-
185
-
-
-
250
-
309
-
420
-
550
-
700
-
825
-
D
2 10 60 70 80 85 95 140 185 225 400
3 105 150 185 205 250 309 420 550 700 825
4 105 - 185 - 250 309 420 550 700 825
440V 1
2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- E
3 8 50 55 65 70 80 120 150 180 320
4 80 - 105 - 185 205 250 300 400 700
600V 1 - - - - - - - - - -
2 - - - - - - - - - -
3
4
4
40
25
-
25
50
30
-
35
90
40
100
60
125
75
150
90
200
165
350
F
Category DC5. L/R H 15ms
Ue Poles CK07 CK75 CK08 CK85 CK09 CK95 CK10 CK11 CK12 CK13
in serie G
24V 1 105 150 185 205 250 309 420 550 700 825
2 105 150 185 205 250 309 420 550 700 825
3 105 150 185 205 250 309 420 550 700 825
4 105 - 185 - 250 309 420 550 700 825
48V 1
2
60
105
90
150
110
185
120
205
150
250
185
309
250
420
330
550
420
700
495
825
H
3 105 150 185 205 250 309 420 550 700 825
4 105 - 185 - 250 309 420 550 700 825
60V 1 55 85 105 110 140 175 230 300 390 460
2
3
105
105
150
150
185
185
205
205
250
250
309
309
420
420
550
550
700
700
825
825 I
4 105 - 185 - 250 309 420 550 700 825
125V 1 15 20 20 25 25 40 50 60 80 100
2 80 95 105 150 185 205 250 300 400 700
3 105 150 185 205 250 309 420 550 700 825

220V
4
1
105
-
-
-
185
-
-
-
250
-
309
-
420
-
550
-
700
-
825
-
X
2 8 50 55 65 70 80 120 150 180 320
3 80 95 105 150 185 205 250 300 400 700
4 105 - 185 - 250 309 420 550 700 825
440V 1 - - - - - - - - - -
2 - - - - - - - - - -
3 5 40 40 50 50 60 90 100 100 200
4 65 - 95 - 150 185 205 250 300 400
600V 1 - - - - - - - - - -
2 - - - - - - - - - -
3 40 45 50 75 90 100 125 150 200 350
4 35 - 45 - 75 90 100 125 150 200

D.47
Series M, CL, CK
Direct-on-line starters
• Motors connected directly on-line with a contactor and a
thermal overload relay.
• Symple installation with high starting torque and cur-
rent.
• For use with motors of medium power that do not need
a progressive star

AC-3 Switching off motors during running Ic = Ie


AC-4 Switching off motors during starting Ic = 6 Ie
Motorstarters

Torque-speed curve Current-speed curve

Current
Torque

Current
A Motor torque

B Resisting torque

C Speed Speed

D Diagram

D.48
Series M, CL, CK

Selection table
Motor Contactor Thermal Fuse
230/200V 400/380V 440/415V 500V 690/660V 1000V relay aM gG-gL
kW A kW A kW A kW A kW A kW A A A
– – – – – – – – 0.06 0.13 – – MC0 MT03A 0.5 1
– – 0.06 0.23 0.06 0.21 0.06 0.17 0.09 0.2 – – MT03B 0.5 1
– – – – – – – – 0.12 0.25 – – MT03B 0.5 1

Direct-on-line starters
0.06 0.39 0.09 0.34 0.09 0.31 0.09 0.26 0.18 0.35 – – MT03C 1 2
– – – – 0.12 0.4 0.12 0.33 – – – – MT03C 1 2
0.09 0.58 0.12 0.44 – – 0.18 0.46 0.25 0.46 – – MT03D 1 2
– – 0.18 0.61 0.18 0.56 0.25 0.6 – – – – MT03D 1 2
– – – – – – – – 0.37 0.7 – – MT03E 2 4
0.12 0.76 0.25 0.78 0.25 0.7 0.37 0.9 0.55 0.9 – – MT03E 2 4
0.18 1.05 0.37 1.13 0.37 1.1 0.55 1.2 0.75 1.1 – – MT03F 2 4
0.25 1.4 – – – – – – – – – – MT03G 2 4
– – 0.55 1.6 0.55 1.5 0.75 1.5 1.1 1.5 – – MT03H 4 6
0.37 2 0.75 2 0.75 2 1.1 2 1.5 2 – – MT03I 4 6
– – 1.1 2.6 1.1 2.5 1.5 2.6 – – – – MT03J 4 6
0.56 2.75 – – – – – – 2.2 2.9 – – MT03J 4 6
0.75 3.5 1.5 3.5 1.5 3.4 2.2 3.8 3 3.5 – – MT03K 6 10
1.1 5 2.2 5 2.2 4.5 3 5 – – – – MT03L 10 16
1.5 7 – – – – – – – – – – MT03M 10 16
– – – – – – – – 3.7 4.6 – – MC1 MT03L 10 16
– – – – – – – – 4 5 – – MT03L 10 16
– – 3 7 3 6.5 3.7 6 – – – – MT03M 10 16
– – – – 3.7 7.3 4 6.5 – – – – MT03M 10 16 A
– – 3.7 8 4 8 – – – – – – MT03N 12 20
2.2 9 4 9 – – – – – – – – MT03N 12 20
– – – – – – – – 5.5 6.7 – – MC2 MT03M 12 20
– – – – – – 5.5 9 – – – – MT03N 16 20 B
3 12 5.5 12 5.5 11 – – – – – – MT03P 16 20

– – 0.06 0.23 0.06 0.21 0.06 0.17 0.09 0.2 – – CL00 RT1B 2 4

0.06

0.39

0.09

0.34

0.09

0.31
0.09
0.12
0.26
0.33
0.12
0.18
0.25
0.35




RT1C
RT1C
2
2
4
4
C
0.09 0.58 0.12 0.44 0.12 0.4 0.18 0.46 0.25 0.46 – – RT1D 2 4
– – 0.18 0.61 0.18 0.56 0.25 0.6 – – – – RT1D 2 4

0.12

0.76

0.25

0.78

0.25

0.7

0.37

0.9
0.37
0.55
0.7
0.9




RT1F
RT1F
2
2
4
4
D
0.18 1.05 0.37 1.13 0.37 1.1 0.55 1.2 0.75 1.1 – – RT1G 2 4
0.25 1.4 0.55 1.6 0.55 1.5 0.75 1.5 1.1 1.5 – – RT1H 2 6
0.37 2 0.75 2 0.75 2 1.1 2 1.5 2 – – RT1J 4 6
0.55 2.75 1.1 2.6 1.1 2.5 1.5 2.6 2.2 2.9 – – RT1K 4 6
E
0.75 3.5 1.5 3.5 1.5 3.4 2.2 3.8 – – – – RT1K 6 10
– – – – – – – – 3.7 4.6 – – RT1L 6 16
1.1 5 2.2 5 2.2 4.5 – – – – – – RT1L 6 16
1.5 7 – – 3.7 7.3 3.7 6 5.5 7 – – RT1M 10 20 F
– – 3.7 8 – – – – – – – – RT1M 12 25
2.2 9 4 9 4 9 5.5 9 – – – – RT1N 16 25
– – – – – – – – 7.5 9 – – CL01 RT1N 16 25
3 12 5.5 12 5.5 11 7.5 12 – – – – RT1P 16 35 G
3.7 14 – – 7.5 14 – – – – – – CL02 RT1P 20 40
4 16 7.5 16 – – 10 15.5 – – – – RT1S 20 40
– – – – – – – – 11 13 – – CL25 RT1P 20 40
– – – – – – 11 17 13 16 – – RT1S 20 40 H
5.5 21 – – 11 21 13 20 – – – – RT1T 32 50
– – 11 22.5 – – 15 23 – – – – RT1U 32 50

D.49
Series M, CL, CK
Direct-on-line starters

Selection table (continued)


Motor Contactor Thermal Fuse
230/200V 400/380V 440/415V 500V 690/660V 1000V relay aM gG-gL
kW A kW A kW A kW A kW A kW A A A
– – – – – – – – 17 20 – – CL04 RT1T 32 50
7.5 27 15 30 15 28 17.5 26.5 – – – – RT1V 40 63
– – – – – – – – 18.5 23 – – RT1U 32 50
– – – – – – – – 22 25 – – CL45 RT1V 40 63
– – – – – – 18.5 28.5 – – – – RT1V 40 63
– – 18.5 37 18.5 35 22 33 – – – – RT1W 50 80
– – – – – – 25 37.5 30 35 – – RT1W 50 80
11 40 – – 22 40 – – – – – – RT2E (1) 50 80
Motorstarters

– – – – – – – – 33 38 – – CL06 RT2E 50 80
– – 22 44 25 45 – – – – – – RT2G 63 80
15 50 – – – – – – – – – – RT2G 63 80
– – – – – – – – 37 41 – – CL07 RT2E 63 80
– – – – – – 30 45 40 43 – – RT2G 63 80
– – 30 60 30 55 37 55 – – – – RT2H 80 125
18.5 65 – – 37 66 – – – – – – RT2J 80 125
– – – – – – – – 45 49 – – CL08 RT2G 80 125
– – 37 72 – – 45 65 – – – – RT2J 100 125
22 75 – – – – – – – – – – RT2J 100 125
– – – – 45 80 – – – – – – RT2L 100 160
– – – – – – – – 55 60 – – CL09 RT2H 80 125
– – – – – – 50 73 – – – – RT2J 100 125
A 25 84 45 85 50 88 55 80 – – – – RT2L 100 160
30 105 55 105 55 100 – – – – – – CL10 RT2M 125 200

– – – – – – – – – – 55 40 CK75 RT4J 63 80
B – – – – – – – – 75 80 – – RT3C 125 160
– – – – – – – – 90 97 – – RT3D 125 160
– – – – – – 75 105 – – – – RT3D 160 200
37 126 – – – – – – – – – – RT3E 160 200
C 45
– –
150
75

138

75

135

90

129









RT3E
RT3F
200
200
224
224
– – – – – – – – – – 75 54 CK08 RT4 K 80 125
– – – – – – – – – – 90 64 RT3B 100 160
D –















110
132
118
141




RT3E
RT3F
160
200
200
250
– – 90 170 90 165 110 156 – – – – RT3F 200 250
55 182 – – 100 182 – – – – – – RT3F 200 250
– – – – – – – – – – 110 78 CK85 RT4L (1) 100 160
E – – – – – – – – 150 166 – – RT4N (1) 250 315
– – – – 110 200 132 188 – – – – RT4P (1) 250 315
– – 110 211 – – – – – – – – RT4P (1) 250 315
– – – – – – – – – – 132 94 CK09 RT4M (1) 125 160
F – – – – – – – – – – 150 105 RT4M (1) 160 200
– – – – – – – – 160 170 – – RT4N (1) 200 250
– – – – – – – – 185 193 – – RT4P (1) 250 315
– – – – – – – – – – 160 113 CK95 RT4M (1) 160 200
G – – – – – – – – – – 185 130 RT4N (1) 160 200
– – – – – – – – – – 200 141 RT4N (1) 200 250
– – – – – – – – – – 220 155 CK10 RT5A (1) 200 250
– – – – – – – – – – 250 175 RT5A (1) 250 315
H – – – – – – – – 220 230 – – CK95 RT4P (1) 315 400
– – – – 150 269 185 261 250 262 – – RT4R (1) 355 400
– – 150 283 160 285 – – – – – – RT4R (1) 400 425
90 309 160 309 – – 200 281 – – – – RT4R (1) 400 425
I (1) Separate mounting: type RT2XP.

D.50
Series M, CL, CK

Selection table (continued)


Motor Contactor Thermal Fuse
230/200V 400/380V 440/415V 500V 690/660V 1000V relay aM gG-gL
kW A kW A kW A kW A kW A kW A A A
– – – – – – 220 310 280 292 – – CK10 RT5C 400 425
– – – – 185 325 – – 300 307 – – RT5C 425 500
– – – – – – – – 315 322 – – RT5C 425 500

Direct-on-line starters
110 356 185 355 200 350 250 348 335 344 – – RT5D 425 500
– – 220 370 220 385 – – 355 366 – – RT5D 500 500
– – – – – – 280 385 375 390 – – RT5D 500 500
– – 220 408 – – 300 409 – – – – RT5D 500 500
– – – – – – – – – – 280 197 CK11 RT5B 250 315
– – – – – – – – – – 300 211 RT5B 315 355
– – – – – – – – – – 315 221 RT5B 315 355
– – – – – – – – – – 335 234 RT5B 315 355
– – – – – – – – – – 355 245 RT5B 315 355
– – – – – – – – 400 412 – – RT5D 500 500
132 425 – – 250 437 315 426 – – – – RT5D 630 630
– – – – – – 335 456 425 442 – – RT5D 630 630
– – 250 475 280 480 355 485 450 462 – – RT5E 630 630
150 500 – – 300 508 375 513 – – – – RT5E 630 630
160 520 280 530 315 530 400 543 – – – – RT5E 630 630
– – – – – – – – – – 375 256 CK12 RT5B 315 355
– – – – – – – – – – 400 273 RT5C 400 425
– – – – – – – – – – 425 290 RT5C 400 425
– – – – – – – – – – 450 307 RT5C 400 425 A
– – – – – – – – 475 488 – – RT5E 630 630
– – – – – – – – 500 514 – – RT5E 630 630
– – 300 563 335 565 – – – – – – RT5E 630 630
185 609 315 580 355 600 – – – – – – RT5E 630 630 B
200 630 335 630 375 630 450 613 – – – – RT5E 800 800
220 710 355 650 – – 475 647 – – – – RT5E 800 800
– – 375 680 400 673 – – – – – – RT5E 800 800




















475 324
500 341
CK13 RT5C
RT5C
500
500
630
630
C
– – – – – – 500 680 – – – – RT6A 1000 1000
– – 400 720 425 714 – – – – – – RT6A 1000 1000

250 823
– 425 763
450 800
450 756













RT6A
RT6A
1000
1000
1000
1000
D

D.51
Series M, CL, CK
Star-delta starters

For AC squirrel cage motors


In order to use this type of starting, the following conditions This starting system is suitable for machines where the
must be met: resisting torque during starting is less than 1/3 of the motor
The ends of the three stator windings should terminate in a torque (see torque speed curves).
terminal box (6 terminals, see diagram). The target of this type of starting is to reduce the current
The line voltage should be the same as the motor delta during starting to 1/3, there by reducing the linedrop (see
connection voltage. current speed curves).
Reduce the motor torque to 1/3 to smooth out mechanical
stress on the machine and on the load (see torque speed
curves).
Motorstarters

Torque-speed curve Current-speed curve

Current in ∆

Current
Torque

A 1
Current in Y

B 2

3
1 Torque in ∆
C 2 Torque in Y
3 Resisting torque Speed Speed

D
Diagram
E

D.52
Series M, CL, CK

Selection table
Motor Contactors Thermal Fuse
230/200V 400/380V 440/415V 500V 690/660V 1000V Line and Star relay aM gG-gL
kW A kW A kW A kW A kW A kW A Delta A A
2.2 9 4 9 – – 5.5 9 7.5 9 – – CL00 CL00 RT1L 16 25
3 12 5.5 12 5.5 11 7.5 12 – – – – CL00 CL00 RT1M 16 35
3.7 14 – – – – – – – – – – CL00 CL00 RT1N 20 40
4 16 7.5 16 7.5 14 – – – – – – CL01 CL00 RT1N 20 40
– – – – – – – – 11 13 – – CL01 CL00 RT1M 20 40

Star-delta starters
– – – – – – 11 17 – – – – CL01 CL00 RT1N 20 40
5.5 21 11 22.5 11 21 – – – – – – CL02 CL01 RT1P 32 50
– – – – – – – – 15 18 – – CL02 CL01 RT1P 32 50
– – – – – – 15 23 – – – – CL02 CL01 RT1P 32 50
– – – – – – – – 18.5 23 – – CL25 CL02 RT1P 32 50
7.5 27 15 30 15 28 – – – – – – CL25 CL02 RT1S 40 63
– – – – – – 18.5 28.5 22 26 – – CL25 CL02 RT1S 40 63
– – – – 18.5 35 22 33 – – – – CL25 CL02 RT1T 50 80
11 40 18.5 37 – – – – – – – – CL25 CL25 RT1U 50 63
– – – – – – – – 30 35 – – CL03 CL25 RT1T 50 63
– – 22 44 22 40 30 45 – – – – CL03 CL25 RT1U 63 80
15 50 25 50 – – – – – – – – CL04 CL03 RT1V 63 80
– – – – – – – – 37 41 – – CL45 CL03 RT1U 50 80
– – 30 60 30 55 – – – – – – CL45 CL03 RT1W 63 80
18.5 65 – – – – – – – – – – CL45 CL03 RT1W 80 125
– – – – – – 37 55 45 49 – – CL45 CL03 RT1V 63 80
22 75 – – – – – – – – – – CL06 CL04 RT2G 100 160 A
– – 33 65 37 66 – – – – – – CL06 CL04 RT1W 80 100
– – – – – – 45 65 55 60 – – CL06 CL04 RT2E 100 160
– – 37 72 – – – – – – – – CL06 CL04 RT2E 100 160
– – 45 85 45 80 55 80 – – – – CL06 CL04 RT2G 100 160 B
– – – – – – – – 75 80 – – CL07 CL06 RT2G 100 160
30 105 55 105 55 100 – – – – – – CL07 CL06 RT2H 125 160
– – – – – – 75 105 – – – – CL08 CL06 RT2H 125 160
37

126






75

135












CL08
CL08
CL06
CL06
RT2J
RT2J
160
160
200
200
C
– – – – – – – – 90 97 – – CL09 CL06 RT2H 125 160
40 138 – – – – – – – – – – CL09 CL07 RT2L 160 250





75

138




90

129









CL09
CL09
CL07
CL07
RT2J
RT2L
160
160
250
250
D
– – – – – – – – 110 118 – – CL10 CL07 RT2J 160 250
45 150 – – – – – – – – – – CL10 CL07 RT2L 160 250
– – – – – – 110 156 – – – – CL10 CL08 RT2L 200 250
– – 90 170 90 165 – – – – – – CL10 CL08 RT2M 200 250 E
– – – – – – – – 132 141 – – CK75C CL08 RT3C 160 200
55 182 – – – – 132 188 – – – – CK75C CL08 RT3D 200 250
– – – – 110 200 – – – – – – CK75C CL08 RT3D 250 315 F
– – – – – – – – 150 166 – – CK75C CL09 RT3D 200 250
– – – – – – – – 160 170 – – CK75C CL10 RT3D 200 250
– – 110 211 – – 150 218 – – – – CK75C CL10 RT3E 250 315
– – – – 132 240 160 228 – – – – CK75C CL10 RT3E 250 315 G
75 239 – – – – – – – – – – CK75C CL10 RT3E 250 315
– – – – – – – – – – 90 64 CK75C CK75C RT4LJ 80 125
– – – – – – – – – – 110 78 CK75C CK75C RT4LJ 108 160
– – 132 245 – – – – – – – – CK75C CL10 RT3F 315 355 H
– – – – – – – – 185 193 – – CK75C CK75C RT3E 250 315
– – 150 288 150 269 185 261 – – – – CK08C CK75C RT3F 315 355
– – – – 160 285 – – – – – – CK08C CK75C RT3F 315 355
















200 207
220 230




CK08C CK75C
CK08C CK75C
RT3E
RT3E
250
250
315
315
I
90 309 – – – – – – – – – – CK08C CK75C RT3F 315 355
For electrical endurance see page C.34-44, but first divide the rated power and current values shown in the table by 1.73.
The thermal overload relay should be set at 0.58 In of the motor.
X

D.53
Series M, CL, CK
Star-delta starters

Selection table (continued)


Motor Contactors Thermal MotorF
Fuse
230/200V 400/380V 440/415V 500V 690/660V 1000V Line and Star relay aM gG-gL
kW A kW A kW A kW A kW A kW A Delta A A
– – – – – – – – – – 132 94 CK08C CK75C RT4LK 125 160
– – – – – – – – – – 150 105 CK08C CK75C RT3B 125 160
– – – – – – – – – – 160 113 CK08C CK75C RT3B 125 160
– – – – – – – – – – 185 130 CK85B CK75C RT4LL 160 200
– – 160 309 – – 200 281 250 262 – – CK85B CK75C RT4N 355 400
– – – – – – 220 310 – – – – CK85B CK75C RT4N 355 400
– – – – 185 325 – – – – – – CK85B CK75C RT4P 400 425
110 356 185 355 200 350 – – – – – – CK85B CK75C RT4P 400 425
Motorstarters

– – – – – – – – 280 262 – – CK09B CK75C RT4N 315 355


132 425 200 370 220 385 250 348 – – – – CK09B CK75C RT4P 500 500
– – 220 408 – – 280 385 – – – – CK09B CK08C RT4P 500 500
– – – – – – – – – – 200 141 CK09B CK08C RT4LL 200 250
– – – – – – – – – – 220 155 CK09B CK08C RT4LM 200 250
– – – – – – – – – – 250 175 CK09B CK08C RT4LM 200 250
– – – – – – – – 300 307 – – CK09B CK08C RT4N 355 400
– – – – – – – – 315 322 – – CK09B CK08C RT4N 355 400
– – – – – – – – 335 349 – – CK09B CK08C RT4P 500 500
– – – – – – – – – – 280 197 CK95B CK09B RT4LM 250 315
– – – – 250 437 – – – – – – CK95B CK08C RT4P 500 500
– – – – – – – – 355 366 – – CK95B CK85B RT4P 425 500
– – – – – – 300 409 375 390 – – CK95B CK85B RT4P 500 500
A – – – – – – 315 426 – – – – CK95B CK85B RT4P 500 500
150 500 250 475 280 480 – – – – – – CK95B CK85B RT4R 630 630
– – – – – – – – – – 300 211 CK95B CK85B RT4LM 250 315
– – – – – – – – – – 315 221 CK95B CK85B RT4LM 250 315
B – – – – – – – – 400 412 – – CK95B CK85B RT4R 500 500
– – – – – – – – 425 442 – – CK95B CK85B RT4R 500 500
– – – – 300 508 335 456 450 462 – – CK10C CK85B RT5C 630 630
160 520 – – – – 355 485 – – – – CK10C CK85B RT4C 630 630
C –




280

530

315

530
375

513









CK10C
CK10C
CK85B
CK85B
RT5C
RT5C
630
630
630
630
– – 300 563 355 561 – – – – – – CK10C CK85B RT5C 630 630
– – 315 580 – – – – – – – – CK10C CK85B RT5C 630 630
D 185

609





355

600










335

234
CK10C
CK10C
CK85B
CK09B
RT5C
RT5A
800
315
800
355
– – – – – – – – – – 355 245 CK10C CK09B RT5A 315 355
– – – – – – – – – – 375 256 CK10C CK09B RT5A 315 355
– – – – – – – – – – 400 273 CK10C CK09B RT5A 355 400
E – – – – – – – – – – 425 290 CK10C CK09B RT5A 355 400
– – – – – – – – – – 450 307 CK10C CK09B RT5A 355 400
– – – – – – – – 475 488 – – CK10C CK09B RT5C 630 630
– – – – – – – – 500 514 – – CK10C CK09B RT5C 630 630
F – – – – – – 400 543 530 545 – – CK10C CK09B RT5C 630 630
– – – – 375 587 425 580 560 575 – – CK10C CK09B RT5C 630 630
200 630 335 630 375 630 450 613 – – – – CK10C CK09B RT5D 800 800
– – 355 650 – – – – – – – – CK10C CK09B RT5D 800 800
G – – – – – – – – 600 616 – – CK10C CK95B RT5D 800 800
– – – – 400 622 475 647 630 646 – – CK10C CK95B RT5D 800 800
– – – – – – – – – – 475 324 CK10C CK95B RT5B 355 400
– – – – – – – – – – 500 341 CK10C CK95B RT5B 400 425
H – – – – – – – – – – 600 407 CK10C CK95B RT5B 500 500
– – – – 400 673 425 659 – – – – CK10C CK10C RT5D 800 800
– – 375 680 – – 500 680 670 688 – – CK11C CK10C RT5D 800 800
220 710 400 720 425 714 530 725 710 729 – – CK11C CK10C RT5D 800 800
I –




425

763
450
475
756
798
560

762

750

770





CK11C
CK11C
CK10C
CK10C
RT5E
RT5E
1000
1000
1000
1000
– – – – – – 600 817 – – – – CK11C CK10C RT5E 1000 1000
For electrical endurance see page C.34-44, but first divide the rated power and current values shown in the table by 1.73.
X The thermal overload relay should be set at 0.58 In of the motor.

D.54
Series M, CL, CK

Selection table (continued)


Motor Contactors Thermal Fuse
230/200V 400/380V 440/415V 500V 690/660V 1000V Line and Star relay aM gG-gL
kW A kW A kW A kW A kW A kW A Delta A A
250 823 – – – – – – – – – – CK11C CK10C RT5E 1000 1000
– – – – – – – – – – 630 428 CK11C CK10C RT5B 500 630
– – – – – – – – – – 670 455 CK11C CK10C RT5C 500 630
– – 450 800 – – – – – – – – CK11C CK10C RT5E 1000 1000
– – 475 846 500 840 – – – – – – CK11C CK10C RT5E 1000 1000

Star-delta starters
– – – – – – – – 800 821 – – CK11C CK10C RT5E 1000 1000
– – 500 892 530 890 630 857 850 873 – – CK11C CK10C RT5E 1000 1000
280 910 530 943 560 941 670 912 – – – – CK11C CK10C RT5E 2x630 2x630
300 975 – – – – 710 965 – – – – CK12C CK10C RT5E 2x630 2x630
315 1023 560 996 600 1010 750 1020 – – – – CK12C CK10C RT5E 2x630 2x630
335 1083 – – 630 1058 – – – – – – CK12C CK10C RT5E 2x630 2x630
– – – – – – – – – – 750 510 CK12C CK11C RT5C 630 630
– – – – – – – – 900 924 – – CK13B CK11C RT6A 2x630 2x630
– – – – – – 800 1088 950 975 – – CK13B CK11C RT6A 2x630 2x630
– – 600 1074 – – – – – – – – CK12B CK11C RT5E 2x630 2x630
355 1142 – – 710 1097 – – – – – – CK12B CK11C RT5E 2x630 2x630
– – – – – – – – – – 800 543 CK13B CK11C RT5C 630 800
– – 630 1128 670 1125 – – – – – – CK12B CK11C RT5E 2x630 2x630
375 1206 670 1200 710 1190 850 1156 – – – – CK13B CK11C RT6A 2x800 2x800
400 1286 710 1270 750 1255 – – – – – – CK13B CK11C RT6A 2x800 2x800
425 1364 – – – – – – – – – – CK13B CK12C RT6A 2x800 2x800
– – 750 1342 – – – – – – – – CK13B CK12C RT6A 2x800 2x800 A
For electrical endurance see page C.34-44, but first divide the rated power and current values shown in the table by 1.73.
The thermal overload relay should be set at 0.58 In of the motor.

D.55
Series M, CL, CK
Autotransformer starters

For AC squirrel cage motors


This type of starting is used for machines where the This system also has the following advantages over star-
resisting torque during starting is less than the motor delta starting:
torque (see torque speed curves): – required current and starting torque can be selected.
– Reduce current during starting to the required value – starting can be effected at various points.
(this will depend on the autotransformer voltage ratio – motor voltage continuity during network switching.
selected).
– Reduce motor torque to smooth out mechanical stress
on the machine and on the load (see torque speed
curves). Reduction of the motor will depend on the
autotransformer voltage ratio.
Motorstarters

The two requirements for star-delta starting do not apply


here. That is to say both end of the three windings do not
have to be accessible and the line voltage does not have to
be the same as the delta connection voltage.

Torque-speed curve Current-speed curve

B
Torque

Current

D
Speed Speed

E
Diagram
F
Line Primary Star
contactor contactor contactor
G

D.56
Series M, CL, CK

Selection table
Motor Contactors Thermal Fuse
230/200V 400/380V 440/415V 500V 690/660V 1000V Line Pr. trafo relay aM gG-gL
kW A kW A kW A kW A kW A kW A + Star A A
2.2 9 4 9 4 8 5.5 9 – – – – CL00 CL00 RT1N 16 25

Autotransformer starters
– – – – – – – – 7.5 9 – – CL01 CL00 RT1N 16 25
3 12 5.5 12 5.5 11 7.5 12 – – – – CL01 CL00 RT1P 16 35
3.7 14 – – 7.5 14 – – – – – – CL02 CL00 RT1P 20 40
– – 7.5 16 – – 10 15,5 – – – – CL02 CL00 RT1S 20 40
– – – – – – – – 11 13 – – CL25 CL01 RT1P 20 40
– – – – – – 11 17 – – – – CL25 CL01 RT1S 20 40
5.5 21 11 22.5 11 21 13 20 – – – – CL25 CL01 RT1T 32 50
– – – – – – – – 15 18 – – CL03 CL01 RT1T 32 50
– – – – – – 15 23 – – – – CL04 CL01 RT1U 32 50
7.5 27 15 30 15 28 – – – – – – CL04 CL02 RT1V 40 63
– – – – – – – – 18.5 23 – – CL45 CL02 RT1U 32 50
– – – – – – 18.5 22.5 22 25 – – CL45 CL02 RT1U 40 63
– – – – 18.5 35 22 33 – – – – CL45 CL02 RT1W 50 80
11 40 18.5 37 22 40 – – – – – – CL06 CL03 RT2E 50 80
– – – – – – – – 30 35 – – CL06 CL03 RT2E 50 80
– – 22 44 – – – – – – – – CL06 CL03 RT2G 63 80
15 50 – – – – – – – – – – CL06 CL03 RT2G 63 80
– – – – – – 30 45 – – – – CL07 CL03 RT2G 63 80
– – – – – – – – 37 41 – – CL07 CL04 RT2E 63 80
– – 30 60 30 55 37 55 – – – – CL07 CL04 RT2H 80 125
18.5 65 – – 37 66 – – – – – – CL07 CL04 RT2J 80 125 A
– – – – – – – – 45 49 – – CL08 CL04 RT2G 80 125
– – – – – – – – 55 60 – – CL08 CL04 RT2H 80 125
– – – – – – 45 65 – – – – CL08 CL06 RT2J 80 125
22 75 37 72 – – – – – – – – CL08 CL06 RT2J 80 125 B
– – – – 45 80 55 80 – – – – CL08 CL06 RT2L 100 160
25 84 45 85 50 88 – – – – – – CL09 CL06 RT2L 100 160
– – – – – – – – 75 80 – – CL09 CL06 RT2L 125 160
30

105

55

105

55

100

75

105


90

97




CL10
CL10
CL06
CL07
RT2M
RT2M
160
125
200
200
C
37 126 75 138 75 135 90 129 – – – – CK75C CL07 RT3E 200 224
















110
132
118
141




CK08C
CK08C
CL08
CL08
RT3E
RT3F
160
200
200
250
D
45 150 90 170 90 165 110 156 – – – – CK08C CL08 RT3F 200 250
55 182 – – – – – – – – – – CK08C CL08 RT3F 200 250
– – – – – – – – – – 90 64 CK08C CL08 RT3B 100 160
– – – – – – – – 150 166 – – CK85B CL09A RT4N 250 315 E
– – 110 211 110 200 132 188 – – – – CK85B CL09A RT4P 250 315
– – – – – – – – – – 110 78 CK85B CK75C RT4N 100 160
– – – – – – – – 160 170 – – CK09B CK75C RT4N 200 250
– – – – – – 150 218 185 193 – – CK09B CK75C RT4P 250 315 F
75 239 132 245 132 240 160 228 200 207 – – CK09B CK75C RT4R 315 355
– – – – – – – – – – 150 105 CK09B CK75C RT4M 160 200
– – – – – – – – – – 160 113 CK95B CK08C RT4M 160 200
– – – – – – – – – – 220 155 CK10C CK08C RT5A 200 250 G
– – – – – – – – – – 250 175 CK10C CK85B RT5A 250 315
– – – – – – – – 220 230 – – CK95B CK08C RT4P 315 355
90 309 160 309 – – 220 310 – – – – CK10C CK08C RT5C 400 425
– – – – 185 325 – – 300 307 – – CK10C CK08C RT5C 425 500 H
110 356 220 408 220 385 280 285 335 344 – – CK10C CK85B RT5D 425 500
132 425 – – 250 437 – – – – – – CK11C CK85B RT5D 630 630
– – – – – – – – – – 280 197 CK10C CK09B RT5B 250 315




















335
355
234
245
CK11C
CK11C
CK09B
CK09B
RT5B
RT5B
315
315
355
355
I
– – – – – – 300 409 400 412 – – CK11C CK09B RT5D 500 500
– – – – – – 315 426 – – – – CK11C CK09B RT5D 630 630
150

500

250

475

280

480

335

456






375

256
CK11C
CK12B
CK09B
CK95B
RT5E
RT5B
630
315
630
355
X
– – – – 300 508 375 513 450 462 – – CK12B CK95B RT5E 630 630
160 520 315 580 335 565 – – – – – – CK12B CK95B RT5E 630 630
– – – – – – – – – – 450 307 CK12B CK10C RT5C 400 425
– – – – – – – – 475 488 – – CK12B CK10C RT5D 630 630
200 630 335 630 375 630 450 613 – – – – CK12B CK10C RT5E 800 800
– – – – – – – – – – 500 341 CK13B CK10C RT5C 500 630
– – – – – – – – 500 514 – – CK13B CK10C RT6A 800 800
220 710 425 762 450 756 500 800 – – – – CK13B CK10C RT6A 1000 1000
250 823 450 800 – – – – – – – – CK13B CK10C RT6A 1000 1000

D.57
Series M, CL, CK
Contactors for rotor starters

For AC slip-ring motors


This type of starter is used in machines with resisting Whatever the application, a distinction should be made
torque of any value where it is required to: between the two electrical circuits which are used in this
– Start with reduced peak currents without consequent type of starters:
motor torque reduction, as is the case with high resisting – Stator circuit, present in two categories and ahving a
torques and when starting with reduced peak currents is different breaking current in each:
required. Category AC’2: switching-off motors during running, Ic = Ie
– Control speed for different load or resisting torque Category AC 2: switching-off motors during starting,
values, with reduced peak currents: lifting and transport Ic = 2.5 Ie
gear, flow volume control, etc. – Rotor circuit, with similar characteristics to those in
category AC1.
Motorstarters

Torque-speed curve Current-speed curve

Current
A
Torque

C
Speed Speed

D
Diagram
E
Stator contactor Rotor contactors
F
End contactor Intermediate contactors

D.58
Series M, CL, CK

Stator circuit Rotor circuit


Motor power Con- Thermal Fuse Rotor Contactor
tactor relay

Contactors for rotor starters


230V 400V 440V 500V 690V 1000V Current (1) Max. voltage Intermediate End
220V 380V 415V 660V aM gG-gL
kW kW kW kW kW kW A A A V
– – 11 13 – – CL25 RT1T 32 50 28 1000 CL00 CL00
5.5 11 – – – – CL25 RT1U 32 50 37 1000 CL00 CL01
– – – – 15 – CL03 RT1T 25 40 42 1000 CL00 CL01
– – – – 17 – CL04 RT1T 32 50 48 1000 CL01 CL02
– – – 15 – – CL04 RT1U 32 50 55 1000 CL02 CL25
7.5 15 15 17 – – CL04 RT1V 40 63 60 1000 CL02 CL03
– – – – 18.5 – CL45 RT1U 32 50 75 1000 CL25 CL04
– – 18.5 22 33 – CL45 RT1W 50 80 90 1000 CL25 CL45
11 18.5 22 – – – CL06 RT2E 50 80 98 1000 CL03 CL45
– 22 25 25 33 – CL06 RT2G 63 80 112 1000 CL04 CL06
15 – – – – – CL06 RT2G 63 80 120 1000 CL45 CL06
– – – 30 40 – CL07 RT2G 63 80 135 1000 CL45 CL06
– 30 30 37 – – CL07 RT2H 80 125 147 1000 CL06 CL06
18.5 – 37 – – – CL07 RT2J 80 125 165 1000 CL06 CL07
– – – – 45 – CL08 RT2G 63 80 180 1000 CL06 CL07
– – – – 55 – CL09 RT2H 80 125 187 1000 CL07 CL08
– – – 45 – – CL08 RT2J 80 125 202 1000 CL07 CL09
22 37 45 – – – CL08 RT2J 100 160 240 1000 CL08 CL10

25

45

50
55
63
75



CL10
CL10
RT2J
RT2L
100 160
125 160
247
280
1000
1000
CL08
CL09
CK75C
CK75C
A
– – – – 90 – CK75C RT3D 125 160 315 1000 CL09 CK08C
30 55 55 75 – – CK75C RT3D 160 200 360 1000 CL10 CK85C
37 75 75 90 – – CK75C RT3E 200 250 390 1500 CK75C CK09B
– – – – – 90 CK08C RT3B 100 125 472 1500 CK08C CK95B B
– – – – 110 – CK08C RT3E 160 200 525 1500 CK85B CK95B
– – – – 132 – CK08C RT3F 200 250 585 1500 CK09B CK10C
45 90 90 110 – – CK08C RT3F 200 250 660 1500 CK95B CK10C
55 – 100 – – – CK08C RT4N 250 315 825 1500 CK10C CK11C C
– – 110 132 – – CK85B RT4P 250 315 945 1500 CK10C CK12B
– – – – – 150 CK09B RT4M 125 160 1087 1500 CK11C CK12B
– – – – 160 – CK09B RT4N 200 250 1188 1500 CK11C CK12B
– – – – 200 – CK09B RT4P 250 315 1485 1500 CK12B CK13B D
75 132 132 160 – – CK09B RT4P 315 355 1956 1500 CK13B –
– – – – – 185 CK95B RT4N 160 200 (1) The currents shown relate to the delta connection of the
– – – – – 250 CK10C RT4N 200 250 contactors poles. If the poles are star-connected, divide the values

90

160

160

220
220
300


CK10C
CK10C
RT4P
RT5C
315 355
355 400
given in the column by 1.5.
E
– – 185 – 315 – CK10C RT5C 400 425
110 200 220 250 335 – CK10C RT5C 500 630










280
335
CK10C
CK11C
RT5B
RT5B
250 315
315 355
F
– – – – – 355 CK11C RT5B 315 355
– 220 – 300 400 – CK11C RT5D 500 600
132 – 250 315 – – CK11C RT5D 630 630
150 250 250 335 – – CK11C RT5E 630 630 G
– – – – – 375 CK12B RT5B 355 400
– – – – – 450 CK12B RT5C 400 425
– – 300 375 475 – CK12B RT5E 630 800
220 335 375 – – – CK12B RT5E 800 800 H
– – – – – 500 CK13B RT5C 400 500
– – – – 500 – CK13B RT6A 630 800
Electrical endurance
220 425 – 450 – – CK13B RT6A 1000 1000 ! Stator circuit (see graph AC-2)
250 450 450 500 – – CK13B RT6A 1000 1000 ! Rotor circuit (see graph AC-1) I

D.59
Series M, CL, CK
Contactors for rotor speed drives

Stator circuit Rotor circuit


Motor power (1) Contactor Rotor Rotor voltage Rotor voltage Contactor
current without with
230V 400V 415V 440V 500V 690V 1000V
(2) counter- counter-
220V 380V
current current
kW kW kW kW kW kW kW
Jogging 2.4 4.5 5 5.5 5.5 6.3 – CL00 22 690 500 CL00
10% AC-2 3.7 6.5 7.5 7.5 8 9 – CL01 30 690 500 CL01
5 8 10 10 10 11 – CL02 39 690 500 CL02
7 13 15 15 15 15 – CL25 60 690 500 CL25
9 16.5 19 19 19 19 – CL04 72 690 500 CL04
10.5 19.5 24 24 24 27 – CL45 87 750 600 CL45
13.5 23 27 27 27 30 – CL06 105 750 600 CL06
Motorstarters

18.5 28 32 32 32 35 – CL07 127 750 600 CL07


21 34 40 40 40 45 – CL08 147 750 600 CL08
22.5 39 47 47 47 50 – CL09 177 750 600 CL09
27.5 49 55 55 55 60 – CL10 195 750 600 CL10
38 65 70 70 75 75 – CK75C 220 1000 750 CK75C
40 75 85 85 85 95 80 CK08C 240 1000 750 CK08C
50 85 90 90 100 100 95 CK85B 280 1000 750 CK85B
55 96 110 110 110 120 110 CK09B 315 1000 750 CK09B
70 110 115 115 125 125 120 CK95B 360 1000 750 CK95B
85 147 175 175 175 195 165 CK10C 405 1000 750 CK10C
105 181 220 220 220 233 220 CK11C 525 1000 750 CK11C
124 215 235 235 257 270 250 CK12B 780 1000 750 CK12B
140 250 260 260 300 280 276 CK13B 885 1000 750 CK13B
A
Jogging 2.1 3.7 4.4 4.4 4.4 5 – CL00 18 690 500 CL00
20% AC-2 2.6 4.5 6.1 6.1 6.1 7 – CL01 25 690 500 CL01
B 3.6 6.5 8.2 8.2 8.2 9 – CL02 37 690 500 CL02
6.3 11 12.7 12.7 12.7 11 – CL25 48 690 500 CL25
8 13.8 15.9 15.9 15.9 17 – CL04 60 690 500 CL04
9.2 16 18.5 18.5 18.5 20 – CL45 72 750 600 CL45
C 10.5
13
18.5
23
22
27
22
27
22
27
25
31


CL06
CL07
85
106
750
750
600
600
CL06
CL07
17.3 30 34.6 34.6 34.6 43 – CL08 123 750 600 CL08
19.6 34 39 39 39 47 – CL09 147 750 600 CL09
D 22
32
38
60
46
65
46
65
46
65
55
70

65
CL10
CK75C
165
190
750
1000
600
750
CL10
CK75C
36 75 75 75 75 90 75 CK08C 210 1000 750 CK08C
42 78 85 85 85 100 85 CK85B 240 1000 750 CK85B
47.8 82.5 90 96 96 115 100 CK09B 273 1000 750 CK09B
E 60 96 110 110 110 135 125 CK95B 305 1000 750 CK95B
77 132 140 150 150 190 160 CK10C 348 1000 750 CK10C
89 153 178 178 185 220 185 CK11C 453 1000 750 CK11C
110 190 218 218 220 258 220 CK12B 570 1000 750 CK12B
F 132 228 230 230 258 240 230 CK13B 750 1000 750 CK13B
Electrical endurance 106 x 1.3 operations continued on D.61

(1) Power values shown are not standard as they refer to intermittent service.
G (2) The current shown relates to the delta connection of the contactor poles.
If the poles are star-connected, divide the values given in the column by 1.5.

D.60
Series M, CL, CK

Contactors for rotor speed drives


Stator circuit (continued) Rotor circuit (continued)
Motor power (1) Contactor Rotor Rotor voltage Rotor voltage Contactor
current without with
230V 400V 415V 440V 500V 690V 1000V
(2) counter- counter-
220V 380V
current current
kW kW kW kW kW kW kW
Jogging 1.4 2.8 3.4 3.4 3.4 4 – CL00 14 660 500 CL00
35% AC-2 2.2 3.8 4.5 4.5 4.5 5.5 – CL01 20 660 500 CL01
3 5.5 7.5 7.5 7.5 7.5 – CL02 26 660 500 CL02
4.9 9 10 10 10 11 – CL25 42 660 500 CL25
6.7 12.8 14.8 14.8 14.8 13 CL04 50 660 500 CL04
7 13 15 15 15 17 – CL45 57 750 600 CL45
9 15 18 18 18 20 – CL06 70 750 600 CL06
10.5 18.5 22 22 22 25 – CL07 85 750 600 CL07
13.5 24 28 28 28 33 – CL08 100 750 600 CL08
18.5 29 33 33 33 40 – CL09 120 750 600 CL09
19.6 34 39 39 39 45 – CL10 138 750 600 CL10
25 45 47 47 47 55 60 CK75C 155 1000 750 CK75C
30 55 63 63 63 77 63 CK08C 172 1000 750 CK08C
35 78 80 80 80 90 75 CK85B 200 1000 750 CK85B
40 75 85 85 85 100 80 CK09B 225 1000 750 CK09B
46 83 100 100 100 135 117 CK95B 250 1000 750 CK95B
63 110 132 132 132 150 132 CK10C 285 1000 750 CK10C
79 136 157 157 160 190 160 CK11C 385 1000 750 CK11C
91 157 165 176 188 220 185 CK12B 495 1000 750 CK12B
115 200 200 200 220 205 202 CK13B 637 1000 750 CK13B
Electrical endurance 106 x 1.3 operations
A
(1) Power values shown are not standard as they refer to intermittent service.
(2) The current shown relates to the delta connection of the contactor poles.
If the poles are star-connected, divide the values given in the column by 1.5.
B

D.61
Series M, CL, CK
Contactors for connection of power transformers
In this application it is essential to ascertain the no-load The contactor should not cut out the short-circuit current; if
inrush current of the transformer Iµ, (magnetisation the protective devices used are fuses, this condition will be
current) which in the majority of cases determines the size intrinsically complied with.
of the contactor. In the case however of devices with tripping contacts the
general line circuit breaker will be driven rather than the
Two cases are illustrated in the table: contactor coil.
– No-loap inrush current up to 20 times the rated
transformer current
– No-loap inrush current up to 40 times the rated
transformer current.
Motorstarters

Selection table
Iµ Iµ
= 20 = 40 Contactor
Ie Ie
230V 380V 230V 380V
240V 400V 240V 400V
kVA kVA kVA kVA
2 3.5 1 1.75 CL00A
2.75 5 1.37 2.5 CL01A
4 7 2 3.5 CL02A
5.75 10 2.85 5 CL25A
5.75 10 2.85 5 CL03A
7.25 12.5 3.65 6.25 CL04A
A 9 15.5 4.50 7.75 CL45A
10 17 5 8.5 CL05A
12 21 6 10.5 CL06A
15 25 7.5 12.5 CL07A
B 20 35 10 16 CL08A
25 40 12.5 20 CL09A
30 50 15 25 CL10A
35 55 17 27 CK75C
C 40 60 20 30 CK08C
45 75 22 35 CK85B
50 85 25 42.5 CK09B
80 150 40 75 CK10C
D 100 170 50 85 CK11C
127 215 64 107 CK12B
160 280 80 140 CK13B

D.62
Series M, CL, CK
Contactors for capacitors (category AC6b)
The most usual application of capacitors is for centralised GE Power Controls contactors are fitted with specially
automatic power factor (cos ϕ) correction. A characteristic treated hardened alloy contacts which are highly resistent
of capacitors is the high overcurrent which appears as to welding and are therefore capable of withstanding high
they are connected. current peaks on connection.
Such overcurrents are due to: The operation conditions taken as a basis for usage are:

Contactors for capacitors


- Harmonic currents produced by saturated transformers, - Near presence of other previously connected capacitors
rectifiers, etc. with a total power of up to eight times that of the
- Transient currents, the frequency and amplitude of capacitor to be connected.
which depend on the network inductance and the - Shock coils reactances with a minimum inductance of
capacitor size. 4µH. These can be obtained by making 4 or 6 turns of
- Additional transient currents arising where a capacitor is 15cm windings on the conductor of each phase.
connected when others have already been connected, - Fast discharge resistor for reconnection within
and caused by discharging of the latter. 60 seconds.

Diagram

Line
transformer Reactances
Shunt connected
capacitors A
Fuses

Contactor B
Fast discharge resistors
Capacitor C
bank

Selection table
D
Contactor θ ≤ 55ºC θ ≤ 70ºC
Type Ith 220V 400V 415V 500V 690V 220V 400V 415V 500V 690V Fuse I max.
230V 660V 230V 660V gl - gG (peak) E
240V 240V
A kvar kvar kvar kvar kvar kvar kvar kvar kvar kvar A A
CL00A 25 3 5 5.5 6.5 5.7 2.4 4 4.5 5.2 4.5 10 1000
CL01A
CL02A
25
32
4.5
6.5
9.5
11
10.5
12
12.5
14.5
11
12.5
3.6
5.2
6
8.5
6.5
9
10
11.5
7
10
16
25
1000
1000
F
CL25A 45 7.5 12.5 14 16 15 6.5 10 11 13 12 25 1000
CL03A 45 9 15 16.5 20 17.5 7.2 12 13 16 14 35 2500
CL04A
CL45A
60
60
12.5
16.5
21
25
23
27
27.5
32
24
30
10
13
17
20
18
22
22
25
19.5
22
40
50
2500
2500
G
CL06A 90 22 40 43 52 50 17 30 33 41 35 80 3500
CL07A 110 25 45 48 58 65 19 35 37 46 40 125 3500
CL08A 110 30 50 54 65 70 22 40 43 52 50 125 3500
CL09A 140 40 65 70 85 95 35 58 62 75 85 160 3500
H
CL10A 140 45 70 80 90 105 40 60 64 65 75 160 3500
CK75C 250 60 110 118 145 150 48 88 94 116 120 250 5000
CK08C 250 70 125 135 162 170 56 100 107 130 136 250 5000
CK85B 315 80 150 160 195 200 64 120 130 156 160 315 5000 I
CK09B 315 95 165 177 215 230 85 148 160 192 205 315 5000
CK95B 450 105 190 205 250 288 95 175 188 230 265 450 5500
CK10C 600 135 260 280 340 370 120 235 252 375 330 630 10000
CK11C 700 190 325 350 425 450 152 260 280 340 360 800 10000 X
CK12B 1000 250 400 430 520 600 200 320 344 416 480 1000 12000
CK13B 1250 315 525 565 685 650 252 420 452 548 520 1250 15000
Electrical endurance: 100.000 operations

D.63
Series M, CL, CK
Contactors for control lighting circuits
The characteristics of the most usual lighting systems are 1.6 and 2 times the rated current and will hold for between
as follows: 3 and 5 minutes.
The power factor is of the order of 0.6 and this can be
Incandescent lamps improved up to approximately unit value by means of
The connection current in very high -of the order of 15 compensating capacitors. In such cases, the
times- rated current. Although this is a very short connection power of the capacitor must be taken into
duration, it is only taken into account in order for the account, the effect of which is appreciably greater on the
contactor connection current not to be exceeded. The smaller contactors.
power factor is always maintained at 1.
High pressure sodium vapour lamps
Fluorescent lamps The connection current values varies, depending on type,
The connection current is slightly higher than rated between 1.3 and 1.6 times the rated current and will hold
Motorstarters

current. The power factor is about 0.5. To improve up to between 3 and 5 minutes.
0.9, compensating capacitors can be used. In such cases, The power factor is of the order of 0.45 and this can be
the connection power of the capacitor must be taken into improved up to apporximately unit value by means of
account, the effect of which is appreciably greater on the compensating capacitors. In such cases, the
smaller contactors. connection power of the capacitor must be taken into
account, the effect of which is appreciably greater on the
High pressure mercury vapour lamps smaller contactors.
The connection current varies, depending on type, between

Selection table
A TYPES Maximum number of lamps per phase at 230V
W A µF MCR MC0 MC1 MC2 RL CL00 CL01 CL02 CL25

B Incandescent 60 0.27 27 37 59 59 59 62 62 70 77
100 0.45 16 22 35 35 35 40 40 50 60
200 0.91 8 11 17 17 17 20 20 25 30
300 1.36 5 7 11 11 11 13 13 17 20
C 500 2.27 3 4 7 7 7
3
8
4
8
4
10
5
12
6
1000 4.5 1 2 3 3
2000 9.1 0 1 1 1 1 1 1 2 3
Fluorescent 15 0.23 51 61 79 79 79 88 98 126 155
D Single arrangement
Without compensation
20
40
0.37
0.44
32
28
38
33
49
41
49
41
49
41
57
48
61
51
78
66
110
93
65 0.7 18 21 26 26 26 30 32 41 58
100 1.5 8 10 12 12 12 14 16 19 27

E Fluorescent
Single arrangement
15
20
0.23
0.25
3.5
4.5
26
20
32
25
49
38
49
38
49
38
61
48
77
61
94
74
111
87
With compensation 40 0.3 4.5 20 25 38 38 38 48 61 74 87
65 0.45 7 13 14 25 25 25 31 39 47 56
100 0.7 18 5 6 9 9 9 11 14 17 21
F High pressure mercury 250 2.13 5 5 5 6 6 6 8 10 12
vapour 400 3.25 3 3 4 4 4 4 5 6 8
Without compensation 700 5.4 2 2 2 2 2 2 3 4 5
1000 7.5 1 1 2 2 2 2 2 3 3
G High pressure mercury 250 1.3 20 9 9 9 9 11 11 14 18 22
vapour 400 2.1 25 7 7 7 7 7 7 9 11 14
With compensation 700 3.6 40 5 5 5 5 4 4 5 6 8
1000 5.3 60 3 3 3 3 3 3 3 4 5
H High pressure sodium 250 3 3 3 4 4 4 4 5 7 9
vapour 400 4.4 2 2 3 3 3 3 4 5 6
Without compensation 1000 10.3 1 1 1 1 1 1 2 2 2
High pressure sodium 250 1.45 40 5 5 5 5 10 10 12 16 20
I vapour
With compensation
400
1000
2.5
5.5
45
100
4
2
4
2
4
2
4
2
6
3
6
3
7
3
9
4
11
5
Metal iodide 250 2,17 - 3 3 4 4 4 4 5 7 9
Without compensation 400 3,48 - 2 2 2 3 3 3 3 4 6
X 700
1000
6,09
8,7
-
-
1
1
1
1
1
1
1
1
1
1
1
1
2
1
2
2
3
2
2000 17,39 - 0 0 0 1 1 1 1 1 1
Metal iodide 250 1,4 32 0 6 6 7 7 7 9 11 16
With compensation 400 2,0 45 0 4 5 5 5 5 6 8 11
700 3,6 65 0 2 3 3 3 3 3 4 6
1000 5,3 85 0 2 2 2 2 2 2 3 4
2000 10,6 100 0 0 0 0 0 1 1 2 2

D.64
Series M, CL, CK

Contactors for control lighting circuits


Diagrams
Single-phase circuit 3-phase circuit, 3-phase circuit,
The total number of lamps will be as lamps delta-connected lamps star-connected
shown in the table. The total number of lamps will be as The total number of lamps will be as
shown in the table, multiplied by 1.73 shown in the table, multiplied by 3 and
and distributed in three equal distributed in three equal quantities.
quantities.

Maximum number of lamps per phase at 230V A


CL03 CL04 CL45 CL06 CL07 CL08 CL09 CL10 CK75C CK08C CK09 CK95 CK10 CK11 CK12 CK13

77 85 122 156 191 222 264 284 333 410 555 820 1320 1550 1860 1860 B
60 66 73 95 116 133 160 170 200 246 333 490 790 930 1120 1120
30 33 36 47 58 66 79 84 99 122 165 240 390 460 550 550
20 22 24 31 38 44 53 56 66 81 110 165 260 300 370 370
12
6
12
6
14
7
19
9
23
11
26
13
31
16
33
17
39
20
48
24
66
33
95
50
155
80
185
90
220
110
220
110
C
3 3 3 4 5 7 8 8 10 12 16 25 40 45 55 55
177 224 237 355 390 434 496 553 790 988 1245 1770 2340 2740 3910 4890
125
105
139
118
147
124
221
186
243
204
270
227
309
260
344
289
490
413
614
516
774
650
1090
920
1460
1220
1700
1430
2430
2045
3040
2550
D
66 74 78 116 127 142 163 181 259 324 409 570 770 900 1280 1600
30 34 36 54 59 66 76 85 121 151 190 270 360 420 600 750
119
92
134
103
149
115
191
148
232
180
273
212
312
243
347
270
496
385
621
482
786
610
900
700
1240
960
1450
1120
1740
1350
1740
1350
E
92 103 115 148 180 212 243 270 385 482 610 700 960 1120 1350 1350
59 66 74 95 115 136 155 173 248 310 393 440 610 720 860 860
23 23 29 37 45 53 60 67 96 120 152 170 240 280 330 330
14 15 18 27 30 33 36 42 60 75 95 136 181 211 302 377 F
9 10 12 18 20 22 24 28 40 49 62 89 119 138 198 247
5 6 7 11 12 13 14 17 24 30 38 54 71 83 119 149
4 4 5 8 9 9 10 12 17 21 27 39 51 60 86 107
31 27 33 49 55 60 66 77 109 156 156 171 311 311 374 467 G
25 17 20 31 34 37 41 48 87 125 125 137 249 249 299 374
16 10 12 18 20 22 24 28 54 78 78 86 156 156 187 234
10 7 8 12 13 15 16 19 36 52 52 57 104 104 125 156
10 11 13 19 21 24 26 30 43 54 68 96 129 150 214 268 H
7 7 9 13 15 16 18 20 29 37 46 66 88 102 146 183
3 3 4 6 6 7 7 9 12 16 20 28 37 44 62 78
16 25 30 44 49 54 59 69 57 81 81 90 163 163 195 244
14
7
14
6
17
8
26
12
29
13
31
14
34
16
40
18
51
23
72
33
72
33
80
36
145
65
145
65
174
78
217
98
I
12 12 12 19 21 23 25 29 41 52 65 93 124 145 207 259
8 8 8 12 13 14 16 18 26 32 41 58 78 91 129 162
4
3
4
3
4
3
7
5
7
5
8
6
9
6
10
7
15
10
18
13
23
16
33
23
44
31
52
36
74
52
92
65
X
2 2 2 2 3 3 3 4 5 6 8 12 16 18 26 32
21 21 21 32 36 39 43 50 68 97 97 107 195 195 234 292
15 15 15 23 25 28 30 35 48 69 69 76 138 138 166 208
8 8 8 13 14 15 17 19 34 48 48 53 96 96 115 144
6 6 6 8 9 10 11 13 26 37 37 40 73 73 88 110
3 3 3 4 5 5 6 7 22 31 31 34 62 62 75 93

D.65
ASTAT S
Small soft starter with integral by-pass

ASTAT S is compact, easy to operate soft starter, designed for use with
standard 3-phase squirrel cage motors. It provides an advanced method of
reducing current during motor starting and stopping.
ASTAT S will start supplying a reduced voltage to the motor, increasing up to
the rated voltage, so avoiding, high currents and generating soft
starting and stopping.
The motor has to be able to start in a reduced voltage.

• Solid soft starter for standard 3ph AC motors up to 30kW


at 400V AC
• Voltage ratings up to 600V
Motorstarters

• Two phase control with integral by-pass


• Compact, small case
• DIN rail mounting. Optional from 31A
• Start and soft stop features

Marking Technical data


A
Ratings
Voltage ratings 3ph AC systems
220/230V (+10%, -15%) for units QA02P_ _ _ S
B 380/415V (+10%, -15%) for units QA12P _ _ _ S
480/500V (+10%, -15%) for units QA22P _ _ _ S
575/600V (+10%, -15%) for units QA32P _ _ _ S
Frequency range 50/60Hz (±5%)
C Load 3ph, AC standard motors

Control specifications
D Ramp up 0,5 - 10 s
Ramp down 0,5 - 10 s
Initial voltage 0 - 80% Un
Starting torque 0 - 64% Tn
E
I/O control
Inputs one input for Start/Stop
F Outputs one output for «End of Ramp» signal
for ratings 31, 44, 58A

G Ambient conditions
Operating temperature 0 to 40ºC. Up to 60ºC derating by 1,2% per ºC
Storage temperature -20 to 70ºC
Relative humidity up to 80%, without condensation
H Max. altitude up to 1000m.
Above this derate by 5% each 100m
Protection degree IP20

X
Order codes ! page D.67
Diagrams ! page D.68
Function ! page D.69
Dimensions ! page D.70

D.66
ASTAT S
Small soft starter with integral by-pass
Input Current Maximum Maximum motor power (1) Cat. No. Ref. no. Pack
voltage rating (2) current 220/230V 380/415V 480/500V 575/600V
V CA A A kW / Hp kW / Hp kW / Hp kW / Hp
220 8 28 1.5 / 2 - - - QA02P008S 120881 1
17 60 4 / 5.5 - - - QA02P017S 120882 1
22 77 5.5 / 7.5 - - - QA02P022S 120883 1
31 110 7.5 / 10 - - - QA02P031S 120884 1
44 150 11 / 15 - - - QA02P044S 120885 1
58 200 15 / 20 - - - QA02P058S 120886 1

400 8 28 - 4 / 5.5 - - QA12P008S 120892 1


17 60 - 7.5 / 10 - - QA12P017S 120893 1
22 77 - 11 / 15 - - QA12P022S 120894 1

Small soft starters


31 110 - 15 / 20 - - QA12P031S 120895 1
44 150 - 22 / 30 - - QA12P044S 120896 1
58 200 - 30 / 40 - - QA12P058S 120897 1

500 8 28 - - 5.5 / 7.5 - QA22P008S 120898 1


17 60 - - 11 / 15 - QA22P017S 120899 1
22 77 - - 15 / 20 - QA22P022S 120900 1
31 110 - - 22 / 30 - QA22P031S 120901 1
44 150 - - 30 / 40 - QA22P044S 120902 1
58 200 - - 45 / 60 - QA22P058S 120903 1

600 8 28 - - - 7.5 / 10 QA32P008S 120904 1


17 60 - - - 15 / 20 QA32P017S 120905 1
22 77 - - - 22 / 30 QA32P022S 120906 1
31 110 - - - 30 / 40 QA32P031S 120907 1
44 150 - - - 37 / 50 QA32P044S 120908 1
58 200 - - - 55 / 75 QA32P058S 120909 1 A

Accessory DIN rail mounting kit for types 31A, 44A and 58A QAOPTDIN 120910 1
B
(1) Ratings for standard 4-poles AC motors
(2) See Operations/hour in table below
Cycles/hour includes both soft start and soft stop
C
Time between rampings Start/Stop
Starting Ramp 1 sec. Ramp 2 sec. Ramp 5 sec. Ramp 10 sec. D
current
QA_2P008S 8 7 15 35 70
16 16 33 77 155
24
28 (*)
26
32
51
62
125
155
250
-
E
QA_2P017S 17 7 15 35 70
34 16 33 77 155
51 26 51 125 250
60 (*) 32 62 155 - F
QA_2P022S 22 7 15 35 70
44 16 33 77 155
66 26 51 125 250

QA_2P031S
77 (*)
31
32
4
62
8
155
20
-
40
G
62 8 15 38 76
93 12 24 62 124

QA_2P044S
110 (*)
44
15
4
31
8
80
20
-
40 H
88 8 15 38 76
132 12 24 62 124
155(*) 15 31 80 -
QA_2P058S 58 4 8 20 40 I
116 8 15 38 76
174 12 24 62 124
200 (*) 15 31 80 -
(*) Maximum starting current at all
X

D.67
ASTAT S
Diagrams

Control by push-buttons,
Control by permanent command line contactor and thermal overload
(soft start and stop) relay (soft start)
Motorstarters

start/stop

Control by push-buttons and line Forward/reverse control by


B contactor (soft start) push-buttons (3)

H
Motor power ASTAT S Q1 Q2 KM1 Q3 F1-F2 S1-S2-S3
380/415V Thermal
kW Hp Am fuses Contactor overload relay

I 4
7.5
5.5
10
QA12P008
QA12P017
GPS1B*AK
GPS1B*AN
10
25
CL25A
CL25A
RT A 1N
RT A 1S
-
-
P9-P3
P9-P3
11 15 QA12P022 GPS1B*AP 32 CL25A RT A 1T - P9-P3
15 20 QA12P031 GPS1B*AR 40 CL04A RT A 1V - P9-P3
22 30 QA12P044 GPS2B*AT 63 CL06A RT A 2F - P9-P3
X 30 40 QA12P058 GPS2B*AU 80 CL07A RT A 2H - P9-P3
Coordination type 2
(1) Use dry contact only.
(2) End of Ramp output relay (only types 31A, 44A and 58A.
(3) Forward/Reverse operation must be done when motor is not rotating.
(4) Ground terminal only for types 31A, 44A and 58A.

D.68
ASTAT S
Performances

Direct-on-line start ASTAT S soft start

DOL Uo=0.5Un, To=25Tn, RAMP UP 0.9s

Voltage
Voltage

Small soft starters


Current

Current
Speed

Time Speed Time

Direct-on-line stop ASTAT S soft stop A

DOL RAMP DOWN 0.5s


B
Voltage

Voltage

D
Current

Current

E
Speed

Speed

F
Time Time

D.69
ASTAT S
Dimensional drawings
Small soft starter with integral by-pass

TYPE Weight (kg) TYPE Weight (kg)


QA12P008S 0.470 QA_2P017S 0.610
QA22P008S 0.470 QA_2P022S 0.650
QA32P008S 0.650
Motorstarters

Dimensions in mm Dimensions in mm

TYPE Weight (kg)


QA_2P031S 1.370
A QA_2P044S 1.400
QA_2P058S 1.400

B 2

C 2

X
Dimensions in mm

D.70
ASTAT S
Notes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Small soft starters


. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

D.71
ASTAT SD
Soft starters for 3ph motors up to 20 kW

• Solid state soft starter for 3ph AC motors up to 20kW


• Working voltage up to 500VAC
• With built-in analogue control panel
• Three phase - full wave control (6 thyristors)
• Excellent basic functions
Motorstarters

Analogue control panel Technical data


A
Ratings
3ph AC systems up to 440V, + 10%, - 15% for types QS1_NA
B up to 500V, + 10%, - 15% for types QS2_NA
Frequency range 49 - 62 Hz

C Control specifications
Control system Digital system with microcontroller. Starting ramp with
progressive increase in voltage and current limitation
Initial voltage (pedestal) 40% - 90% Un
D Starting torque 15% - 80% Mdir.start
Kick start 90% Un (80% Mdir.start), 400ms
Motor current (Im) 0.5 to 1 Ir (nominal ASTAT)
Current limitation 2 to 5 x Ir
E Acceleration ramp time 0.5 to 60 s
Energy savings Output voltage reduction according to power factor
Override Fixed output voltage permanently equal to supply voltage
Soft stop time Max. 2 x t acceleration time
F
Operation
External control Start - Stop
G Acceleration phase Adjustable time
Permanent phase (choice) Energy savings / Override
Stop phase (choice) Power cutt-off / Ramp

H
Inputs / Outputs
Input Two optical couplings for Start/Stop
Output One relay either Run or End of ramp (1NO)
I
Protections
Current limit Adjustable from 2 to 5 Ir
X Loss on input phase Trip at 3 sec.
Thyristor short-circuit Trip at 200 ms
Order codes ! page D.73 Loss on output phase Trip at 3 sec.
Diagrams ! page D.74 Supply frequency error Will not start if f < 4a8Hz or f > 62Hz
Dimensions ! page D.76 Error (CPU) 60ms

D.72
D.72
ASTAT SD
Technical data (continued)

Ambient conditions
Temperature 0 to +55ºC
(derate output current by 1.5% / ºC above 45ºC)
Relative humidity 95% without condensation
Maximum altitude 3000 m

Soft starters up to 20 kW
(derate output current by 1% / 100 m above 1000 m)
Mounting position Vertical

Description of the terminals


1L1, 3L2, 5L3 Power supply (max. 440V or 500V depending type)
2T1, 4T2, 6T3 Outputs to motor
A1/A2, B1/B2 Command supply inputsa (110/120V - 220/240V AC)
11, 14 Internal relay output Run / End of ramp (1NO)
1, 57 Run command input
2, 57 Stop command input

Output contacts specifications


Maximum usage voltage 380V CA
Thermal current Ith 8A
Usage specifications
AC15 220V / 3A - 380V / 1A
DC15 Max. 30V / 3.5A
A

B
Order codes
IEC ratings Light duty Heavy duty
Current Maximum
rating starting (3 x Ir, 30sec.) (4.5 x Ir, 30sec.)
Cooling
convection
Cat. No. Ref. no. C
Ir current 220V 380V 440V 480V 220V 380V 440V 480V
240V 415V 500V 240V 415V 500V
A A kW kW kW kW kW kW kW kW
Input voltage 5 25 1.1 2.2 2.2 1.1 2.2 2.2 Natural QS1BNA 120460 D
220 - 440 VCA 9 45 2.2 4 4 2.2 4 4 Natural QS1DNA 120462
+ 10%, -15% 12 60 3 5.5 6.3 3 5.5 6.3 Natural QS1FNA 120464
48 < f (Hz)< 62 16 80 4 7.5 7.5 3.7 6.3 7.5 Natural QS1GNA 120466
22 110 5.5 11 11 5.5 11 11 Natural QS1HNA 120468
34 170 7.5 15 18.5 7.5 15 17 Natural QS1INA 120470 E
Input voltage 5 25 1.1 2.2 2.2 3 1.1 2.2 2.2 3 Natural QS2BNA 120461
220 - 500 VCA 9 45 2.2 4 4 5.5 2.2 4 4 5.5 Natural QS2DNA 120463
+ 10%, -15% 12 60 3 5.5 6.3 7.5 3 5.5 6.3 7.5 Natural QS2FNA 120465
48 < f (Hz)< 62 16 80 4 7.5 7.5 10 3.7 6.3 7.5 10 Natural QS2GNA 120467 F
22 110 5.5 10 11 13 5.5 10 11 13 Natural QS2HNA 120469
34 170 7.5 15 18.5 20 7.5 15 15 20 Natural QS2INA 120471

UL ratings Light duty Heavy duty


G
Current Maximum Cooling Cat. No. Ref. no
rating starting (3 x Ir, 30sec.) (4.5 x Ir, 30sec.) convection
Ir current 200V 230V 460V 200V 230V 460V
A A Hp Hp Hp Hp Hp Hp
Input voltage 5 25 1 1 1 1 Natural QS1BNA 120460 H
200 - 230 V 9 45 2 2 2 2 Natural QS1DNA 120462
12 60 3 3 3 3 Natural QS1FNA 120464
16 80 3 5 3 5 Natural QS1GNA 120466
22
34
110
170
5
10
7.5
10
5
7.5
7.5
7.5
Natural
Natural
QS1HNA
QS1INA
120468
120470
I
Input voltage 5 25 1 1 3 1 1 3 Natural QS2BNA 120461
200 - 460 V 9 45 2 2 5 2 2 5 Natural QS2DNA 120463
12
16
60
80
3
3
3
5
7.5
10
3
3
3
5
7.5
10
Natural
Natural
QS2FNA
QS2GNA
120465
120467
X
22 110 5 7.5 15 5 7.5 15 Natural QS2HNA 120469
34 170 10 10 25 7.5 7.5 20 Natural QS2INA 120471

D.73
D.73
ASTAT SD
Diagrams

Control by permanent command

Control voltage
110/120V AC

Start / Stop

Control voltage
220/240V AC
Motorstarters

(1)

(2)
A

B Control by push-buttons

Control voltage
C 110/120V AC

Start Stop

D Control voltage
220/240V AC

E
(1)

G
(2)
H
(1) These contacts allow for direct action on contactors up to type CL10 at 220 AC.
I See Usage specifications to determine the necessity of an auxiliary relay.
(2) The ASTAT SD has no overload function, so always use an external overload relay to protect the motor

D.74
D.74
ASTAT SD
Permanent command with line contactor

Control voltage
110/120V AC Control
voltage
Start / Stop

Soft starters up to 20 kW
Control voltage
220/240V AC

(1)

(2)

A
Pulse function with line contactor

Control voltage
Control
B
110/120V CA
voltage
Start Stop
C
Control voltage
220/240V CA
D

(1)
E

(2) G

(1) These contacts allow for direct action on contactors up to type CL10 at 220 AC.
See Usage specifications to determine the necessity of an auxiliary relay.
H
(2): Use thermal relay if required by local rules, selecting it according to motor current

I
Data power circuit
ASTAT SD Total Contactor aM Fuses Semiconductor fuses
losses DC1 Jean Müller Jean Müller Typower Silca 680V ~ X
W Type A Type Ref. No. Bussmann Type
QS _ BNA 17 CL00 12 S00C+/üF01/32A/690V R5082953 Size = 00, In = 32A
QS _ DNA 31 CL00 16 S00C+/üF01/32A/690V R5082953 Size = 00, In = 32A
QS _ FNA 37 CL01 20 S00C+/üF01/40A/690V R5083453 Size = 00, In = 40A
QS _ GNA 49 CL02 25 S00C+/üF01/50A/690V R5083553 Size = 00, In = 50A
QS _ HNA 75 CL04 32 S00C+/üF01/80A/690V R5084153 Size = 00, In = 80A
QS _ I NA 86 CL45 63 S1ü01/110/100A/690V R1084321 Size = 00, In = 100A

Coordination type 1

D.75
D.75
ASTAT SD
Dimensional drawings

Soft starters for 3ph motors up to 20 kW

. TYPE A Weight (kg)


QS _ BNA 150 2.1
QS _ DNA 150 2.1
QS _ FNA 180 2.2
QS _ GNA 180 2.2
Dimensions in mm
Motorstarters

.
. .

A
.
TYPE A B Weight (kg)
B QS _ HNA 200 160 2.9
QS _ DNA 250 200 3.4
Dimensions in mm

D
.

F
. .
G

D.76
D.76
ASTAT SD
Notes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Soft starters up to 20 kW
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

D.77
D.77
ASTATplus
Soft starters for 3ph motors up to 850 kW

• Solid state soft starter for 3ph AC motors up to 850 kW


• Three pase - full wave control (6 thyristors)
• Working voltage up to 500V
• Built-in digital operation control panel
• Built-in ASCII and Modbus RTU communications
• Optional ProfibusDP and DeviceNet external communication modules
• High end features and functions
Motorstarters

Digital control panel Technical data


A
Ratings
3ph AC systems Up to 440V, +10%, -15% for Cat. No. QC1_DP
B Up to 500 V, +10%, -15% for Cat. No. QC2_DP
Frecuency range (50-60Hz) Control range of 45 - 65 Hz

C Control specifications
Control system Digital system with microcontroller
Starting ramp with progressive increase in voltage
and current limitation
D Initial voltage (pedestal) 30%-95% Un
Starting torque 10% - 90% Mdirect start
Kick start 95% Un (90% Mdir.start), adjustable 0 to 999ms.
Motor current (lm) 0.4 to 1.2 Ir (rated ASTAT current)
E Tiempo rampa aceleración 1 to 99s (types: standard or linear ramp up)
Energy savings Output voltage reduction according to power factor
Override Fixed output voltage permanently equal to supply voltage
Bypass Direct control of a bypass contactor
F Deceleration ramp time 1 to 120s ( 1s to 99s in secondary ramp)
Modes: coast to stop, soft stop,
pump control or linear ramp down
DC braking 0 to 99s ; 0.5 to 2.5 lr

G Slow speed Forward: 7% or 14% nominal speed


Reverse: 20% nominal speed
Retry 0 to 4 attemps, and 1to 99 sec. retry time
Monitoring Motor current, line voltage, power, power factor
and elapsed time
H

X Order codes ! page D.80


I/O Terminal specifications ! page D.81
I/O wiring ! page D.82
Thermal characteristics ! page D.83
Diagrams ! page D.84
Dimensions ! page D.88

D.78
ASTATplus
Running
External control Start - Stop
Acceleration phase Adjustable time / Pump control
Permanent phase Energy savings / Override
Stop phase Power cut-off / Ramp / DC braking / Pump control

Inputs / Outputs

Soft starters up to 850 kW


Imput 4 digital optocoupled
2 fixed (Start, Stop), and 2 programmable (I3, I4)
1 analogue 0-5VDC for tachogenerator input feedback
2 inputs for motor thermistor
Output 3 programmable relays (1r changeover, 2r, 3r)
1 analogue 0-10V DC output for current metering

Communications
ASCII and Modbus RTU as standard
Profibus DP and DeviceNet as option external modules

Protections
Current limit Adjustable from 1xln to 7xln
Overload Class IEC 10 and 20 (selectable)
Class NEMA 10, 20 and 30 (selectable)
OFF desactivado
Cool-down time after
overload trip 300 s for reset A
Loss on input phase Trip at 3 s
Thyristor shortcircuit Trip at 200 ms
Heatsink overheating Trip at 200 ms
Motor thermistor
Loss on output phase
Trip at 200 ms
Trip at 3s
B
Stalled rotor Trip at 200 ms
Supply frequency error Si f < 45Hz ó f > 65 Hz
Overcurrent
Undercurrent
100 to 150% ln; trip time adjustable from 0 to 99s
0 to 99% ln; trip time adjustable from 0 to 99s
C
Overvoltage 100% to 130% Un; trip time adjustable from 0 to 99s
Undervoltage 0 to 50% Un; trip time adjustable from 0 to 99s
Error (CPU)
Memory
60ms
4 former errors
D
Long start time 2 x ta ( ta= acceleration ramp time)
Long slow speed time 120s

E
Ambient conditions
Temperature 0 to +55º C
(derate output current by 1.5% /ºC above 40ºC)
Relative humidity 95% without condensation F
Maximum altitude 3000 m
(derate output current by 1%/100m above 1000m)
Mounting position Vertical
Protection degree IP 00, (UL open) G

Standards H
CE, cUL, UL CE conforming IEC 947-4-2
UL, cUL conforming UL 508
Conducted and radiated Conforming IEC 947-4-2, Class A
emissions
Electrostatic discharges Conforming IEC 1000-4-2, level 3 I
Radioelectric interferences Conforming IEC 1000-4-6, level 3 and
to IEC 1000-4-3, level 3
Inmunity to fast trasients Conforming IEC 1000-4-4, level 3
Inmunity to surge voltage Conforming IEC 1000-4-5, level 3 X

D.79
ASTATplus
Soft starters for AC motors up to 850 kW - Order codes
IEC ratings Max. Max. Light duty (Class 10) Heavy duty (Class 20) Cooling Cat. No. Ref. no.
current starting
rating current Current 220V 380V 440V 480V Current 220V 380V 440V 480V convection
Ir rating Ir 240V 415V 500V rating Ir 240V 415V 500V
A A A kW kW kW kW A kW kW kW kW
Input voltage 21.8 63 17 4 7.5 7.5 - 14 3 5.5 7.5 - natural QC1FDP 129728
220- 440V 26.5 76.5 21 5.5 11 11 - 17 4 7.5 7.5 - natural QC1GDP 129730
34.3 99 27 7.5 13 15 - 22 5.5 11 11 - natural QC1HDP 129732
+ 10%, -15% 49.9 144 38 10 18.5 22 - 32 7.5 15 18.5 - natural QC1I DP 129734
45 < f (Hz)< 65 74.8 216 58 15 25 30 - 48 13 22 22 - by fan QC1JDP 129736
98.2 283.5 75 22 37 45 - 63 15 30 37 - by fan QC1KDP 129738
112.3 324 86 25 45 50 - 72 20 37 37 - by fan QC1LDP 129740
163.8 472.5 126 37 63 75 - 105 30 55 55 - by fan QC1MDP 129742
243.3 702 187 55 90 110 - 156 40 75 90 - by fan QC1NDP 129744
374.4 1080 288 80 150 165 - 240 63 110 132 - by fan QC1QDP 129746
491.4 1417.5 378 110 200 220 - 315 90 160 200 - by fan QC1RDP 129748
577.2 1665 444 132 220 250 - 370 110 200 220 - by fan QC1SDP 129750
Motorstarters

741 2137.5 570 160 300 355 - 475 150 250 250 - by fan QC1TDP 129752
951.6 2745 732 220 400 450 - 610 200 315 400 - by fan QC1UDP 129754
1326 3825 1020 300 560 600 - 850 250 450 530 - by fan QC1VDP 129756
1677 4837.5 1290 395 715 750 - 1075 355 600 670 - by fan QC1XDP 129758

Input voltage 21.8 63 17 4 7.5 7.5 11 14 3 5.5 7.5 7.5 natural QC2FDP 129729
220- 500V 26.5 76.5 21 5.5 11 11 13 17 4 7.5 7.5 11 natural QC2GDP 129731
34.3 99 27 7.5 13 15 15 22 5.5 11 11 15 natural QC2HDP 129733
+ 10%, -15% 49.9 144 38 10 18.5 22 25 32 7.5 15 18.5 22 natural QC2I DP 129735
45 < f (Hz)< 65 74.8 216 58 15 25 30 37 48 13 22 22 30 by fan QC2JDP 129737
98.2 283.5 75 22 37 45 45 63 15 30 37 37 by fan QC2KDP 129739
112.3 324 86 25 45 50 50 72 20 37 37 45 by fan QC2LDP 129741
163.8 472.5 126 37 63 75 80 105 30 55 55 75 by fan QC2MDP 129743
243.3 702 187 55 90 110 132 156 40 75 90 110 by fan QC2NDP 129745
374.4 1080 288 80 150 165 200 240 63 110 132 160 by fan QC2QDP 129747
A 491.4
577.2
1417.5
1665
378
444
110
132
200
220
220
250
250
315
315
370
90
110
160
200
200
220
220
250
by fan
by fan
QC2RDP
QC2SDP
129749
129751
741 2137.5 570 160 300 355 400 475 150 250 250 335 by fan QC2TDP 129753
951.6 2745 732 220 400 450 500 610 200 315 400 400 by fan QC2UDP 129755
1326 3825 1020 300 560 600 750 850 250 450 530 600 by fan QC2VDP 129757
B 1677 4837.5 1290 395 715 750 850 1075 355 600 670 750 by fan QC2XDP 129759

UL ratings Light duty Heavy duty


Current Max. Cooling Cat. No. Ref. no.
rating starting (3 x Ir, 30 sec.) (4.5 x Ir, 30 sec.) convection
C Ir current 200V 230V 460V 200V 230V 460V
A A Hp Hp Hp Hp Hp Hp
Input voltage 14 70 3 3 - 3 3 - natural QC1FDP 129728
200- 230 V 17 85 3 3 - 3 3 - natural QC1GDP 129730
D 22
34
110
170
5
10
7.5
10
-
-
5
7.5
7.5
7.5
-
-
natural
natural
QC1HDP
QC1I DP
129732
129734
48 240 15 15 - 10 15 - by fan QC1JDP 129736
63 315 20 20 - 15 20 - by fan QC1KDP 129738
72 360 20 25 - 20 20 - by fan QC1LDP 129740
E 105
156
525
780
30
50
30
60
-
-
30
40
30
50
-
-
by fan
by fan
QC1MDP
QC1NDP
129742
129744
240 1200 75 75 - 60 75 - by fan QC1QDP 129746
315 1575 100 125 - 75 100 - by fan QC1RDP 129748
370 1850 125 150 - 100 125 - by fan QC1SDP 129750
F 500
630
2500
3150
150
200
200
250
-
-
150
200
150
200
-
-
by fan
by fan
QC1TDP
QC1UDP
129752
129754
850 4250 300 350 - 250 300 - by fan QC1VDP 129756

Input voltage 14 70 3 3 7.5 3 3 7.5 natural QC2FDP 129729


G 200- 460 V 17
22
85
110
3
5
3
7.5
10
15
3
5
3
7.5
10
15
natural
natural
QC2GDP
QC2HDP
129731
129733
34 170 10 10 25 7.5 7.5 20 natural QC2I DP 129735
48 240 15 15 30 10 15 30 by fan QC2JDP 129737
63 315 20 20 40 15 20 40 by fan QC2KDP 129739
H 72
105
360
525
20
30
25
30
50
75
20
30
20
30
40
60
by fan
by fan
QC2LDP
QC2MDP
129741
129743
156 780 50 60 125 40 50 100 by fan QC2NDP 129745
240 1200 75 75 200 60 75 150 by fan QC2QDP 129747
315 1575 100 125 250 75 100 200 by fan QC2RDP 129749
I 370
500
1850
2500
125
150
150
200
300
400
100
150
125
150
250
350
by fan
by fan
QC2SDP
QC2TDP
129751
129753
630 3150 200 250 500 200 200 400 by fan QC2UDP 129755
850 4250 300 350 700 250 300 600 by fan QC2VDP 129757
Ambient conditions are in accordance with the following ranges and maximum values:
X - Operating temperature ....................................................................0 to +55ºC
- Relative humidity (without condensation)........................................... 95%
- Maximum altitude.....................................................................................3000 m
Reduce usage intensity with 1.5% / ºC from 40ºC and 1% / 100 m from 1000 m.

Optional Device Net communications module QCPDNT 129768


external
modules Profi bus DP communications module QCPPDP 129769

D.80
ASTATplus
I/O terminal board specifications
Power I/O terminals
Terminals Function Description
1L1, 3L2, 5L3 Mains input 3ph input voltage according ASTAT Plus voltage
2T1, 4T2, 6T3 Motor output Output terminals to 3ph AC motor
A1, A2, B1, B2 Control voltage Input control voltage

Soft starters up to 850 kW


110/120VAC, +10%, -15% 220/240VAC, +10%, -15%

Digital inputs
57 Common for This is a common terminal for the digital input terminals specified below
digital inputs
1 Run Run order. Command signal may be provided by one NO dry momentary contact to
terminals 1 and 57
2 Stop Stop order. Command signal may be provided by one NC dry momentary contact to
terminals 2 and 57
NOTE: Run/Stop permanent command is allowed linking 1-57 and using one dry NO contact
to 2-57 terminals
3 Programmable input I3 These two inputs are programmable. Can be assigned to the following internal functions:
4 Programmable input I4 - soft stop - DC brake - linear ramp
- pump control - slow speed control - dual ramp selection
- kick start - reverse slow speed - by-pass function
- override - local / remote control
Command signal should be provided by one NC dry contact to terminals 57-3
or terminals 57-4.
By switching this contact ON/OFF it is possible to enable or disable the assigned function.
A
Digital outputs
11, 12, 14 Programmable relay 1r 11-12 = NC, 11-14 = NO dry contacts B
This relay can be assigned to several internal output functions. As default assigned to
function RUN.
23, 24 Programmable relay 2r 23-24 = NO dry contact
This relay can be assigned to several internal output functions. As default assigned to
function EOR.
C
33, 34 Programmable relay 3r 33-34 = NO dry contact
This relay can be assigned to several internal output functions. As default assigned to
function DC BRAKE
Common for all relay output contacts: Max. usage voltage: 380V AC (B300 - UL)
D
Thermal current Ith: 8A
AC-15: 220V / 3A, 380V / 1A
DC-15: 30V max. / 3.5A
Programmable relays can be assigned to following functions:
E
- End of Ramp - RUN
- DC brake - Slow speed
- Fault - Undercurrent
- Undervoltage - Overcurrent F
- Overvoltage

Analogue I/O G
8 Analog input common (-) This is a common terminal for the analogue input terminal 7 and analogue output terminal 9
7 TG feedback input (+) 0-5V analogue input for speed feedback. It should be provided by a DC tacho-generator
coupled to motor.

9 Current output (+)


This speed feedback signal is required when the «linear ramp» function is used.
0-10VDC analog output for current measurement purpose. Ir correspond to 2Vdc.
H
Rated current is 2VDC. Load impedance 10kΩ or higher.

Motor thermistor terminals I


5, 6 Motor thermistor input This inputs allow a motor thermistor with a response value from 2.8 to 3.2kΩ,
and a reset value from 0.75 to 1kΩ to control motor temperature.
When the motor thermistor is not used, a link must be used in terminals 5-6.
X
Communications
SG, TD, RD Gr, Tx, Rx data - RS232C, 3 wires, half duplex. Maximum cable lengths 3m (10 feet)
- Asynchronous data transmission, 9600 Bauds, 1 bit start, 8 bits data, 1 bit stop, no parity
- Supported ASCII and ModbusRTU (selectable by the user)
- Optional Device Net and Profibus DP external modules

D.81
ASTATplus

I/O wiring
Control voltage
110/120VAC
Serial comm.
RS232C

Control voltage 1
220/240VAC
Motorstarters

1r 2r 3r
Programmable relay outputs 3
Programmable inputs 2
I3 I4

Start / Stop

Earth connection
(permanent command)
4
A Tacho feedback analog
input
Programmable inputs

Motor thermistor input

0 - 10V analog output


B
Start Stop
C (command by push-buttons)
4 4

1 The islotaion contactor DC1, is not required to perform operation to the motor. Be aware however that DC1
D provides galvanic isolation from the incoming line increasing the safety.

2 The programmable inputs I3, I4 are not assigned to any function by default. Check ASTATplus User Manual

3 The programmable relay outputs are assigned to the following functions as default:
E Relay 1r : RUN (RUN status)
Relay 2r : EOR (End Of Ramp)
Relay 3r : DCBR (DC braking control)

4 Important: Use dry contacts only


F
Installation
G When installing the soft starter ASTATplus, keep the following points in mind:

✓ The soft starter should be installed vertically and should hang over a platform or bars.
9
The vertical position is essential for proper cool air circulation.
H
✓ Ambient conditions are in accordance with the following ranges and maximum values:
9
- Operating temperature ...........................................0 to +55ºC

I - Relative humidity (without condensation) .................. 95%


- Maximum altitude .............................................................3000m
Reduce usage intensity with 1.5% / ºC from 40ºC and 1% / 100 m from1000 m.
X ✓ Do not install the soft starter in environments containing explosive or flammable gases, or
9
near important heat sources.
✓ The soft starter should be well ventilated, at least keeping clearance as indicated in
9
illustration (left).
✓ When the soft starter is to be removed on a platform subject to strong vibrations, there
9
should be an elastic base to protect the equipment.
Check User Manual for additional information

D.82
ASTATplus
Thermal characteristics
The ASTATplus allows motor protection according IEC Class 10 or Class 20 and NEMA 10, 20 or 30, free selectable by
parameter «o» (overload).

IEC Class 10 IEC Class 20

Soft starters up to 850 kW


Sec. Sec.

COLD
COLD

HOT HOT

Ir / In Ir / In

NEMA 10 NEMA 20
Sec. Sec.
A

COLD
COLD C
HOT
HOT
D
Ir / In Ir / In

NEMA 30
Thermal memory E
Sec. If the control voltage is not removed, the unit has a cool
down characteristic, the time for cool down is 300 sec. after
the overload trip.
If the control voltage is removed after tripping, wait at least 2
F
minutes before the unit can be restarted.

Operations per hour G


Supposing a cycle T, with starting time of t1, running time of
COLD T-2t1 at rated current and OFF time of t1 sec. at least, the
ASTAT Plus allows the following operations per hour.
H
HOT Starting current Operations/hour Operations/hour
Starting time t1=10 sec. Starting time t1=20 sec.
2 Ir 180 90
Ir / In 3 Ir 160 60 I
4 Ir 30 10

D.83
ASTATplus

Basic diagram by push-buttons

Control voltage
110/120V AC

1
Control voltage
220/240V AC
Motorstarters

1r 2r 3r
Programmable relay outputs 3
Programmable inputs
I3 I4

Start Stop Motor thermistor


Push-button 2
A
1 2 3 4
The isolation contactor In this example, Start The output relays allow The ASTATplus is provided with an electronic motor overload protection, which
DC1, is not required to and Stop command is for a direct action on should be adequate protection for most of the applications.
B perform operation to
the motor. Be aware
enabled by push-bu-
ttons.
contactors according
ratings specified.
Use an external overload protection if required by local codes or to protect the
motor against current unbalance.
however that DC1 pro- Permanent command is
vides galvanic isolation allowed as well, wiring
from the incoming line 1, 2 and 57 terminals
C increasing the safety. accordingly.

Basic diagram by permanent command with by-pass control


D
Control voltage
110/120V AC

E
1
Control voltage
220/240V AC
F

G
1r 2r 3r
Programmable relay outputs 3
H Programmable inputs
I3 I4

I
Start/Stop 4
permanent
X commands 2 By-pass 5 Motor thermistor

1 2 3 4 5
The isolation contactor DC1, is not required In this example, Start The output relays allow CAUTION: By-pass control is
to perform operation to the motor. Be aware and Stop command is for a direct action on In by-pass mode, an allowed using external
however that DC1 provides galvanic enabled by contactors according external overload relay contactor DC2 and
isolation from the incoming line increasing push-buttons. ratings specified. protection must be setting function «zxxx»
the safety. Permanent command is used. to ON.
allowed as well, wiring As alternative by-pass
1, 2 and 57 terminals can be controlled from
accordingly. the outside if «zxxx» is
set to one
D.84 programmable input.
ASTATplus

Basic diagram with jog (slow speed) function


Control voltage
110/120V AC

Soft starters up to 850 kW


1
Control voltage
220/240V AC

1r 2r 3r
Programmable relay outputs 3
Programmable inputs
I3 I4

Start Stop Jog Fw/Rv Motor thermistor


Push-button 2 Slow speed 5

1 2 3 4 5
A
The isolation contactor In this example, Start The output relays allow The ASTATplus is provided with an Slow speed for forward or reverse
DC1, is not required to and Stop command is for direct action on electronic motor overload protection, operation using programmable inputs
perform operation to enabled by contactors according which should be adequate protection for I3, I4.
the motor. Be aware push-buttons. ratings specified. most of the applications. Use an external B
however that DC1 Permanent command overload protection if required by local Jog (slow speed) function:
provides galvanic is allowed as well, codes or to protect the motor against The slow speed function is enabled
isolation from the wiring 1, 2 and 57 current unbalance. by setting «Jxxx» to I3.
incoming line terminals accordingly. For more information, check with
increasing the safety. ASTATplus User’s Manual. C
Basic diagram with DC brake injection
Control voltage D
110/120V AC

E
1
Control voltage
220/240V AC
F

G
1r 2r 3r
Programmable relay outputs 3
Programmable inputs H
I3 I4

I
5
Start/Stop 4
permanent
command 2 Motor thermistor
X
1 2 3 4 5
The isolation contactor In this example, Start The output relays allow The ASTATplus is provided DC brake at stopping time DC brake function
DC1, is not required to and Stop command is for direct action on with an electronic motor is provided by the DC brake The DC brake
perform operation to enabled by push-bu- contactors according overload protection, function and external function may be
the motor. Be aware ttons. ratings specified. which should be adequate contactor DC3. enabled by setting
however that DC1 Permanent command is protection for most of the CAUTION: «Bxxx» to ON.
provides galvanic isola- allowed as well, wiring applications. Use an ex- The 3 contacts of DC3 must For more
tion from the incoming 1, 2 and 57 terminals ternal overload protection be connected in parallel. information, check
line increasing the accordingly. if required by local codes Mandatory between 2T1 with ASTATplus
safety. or to protect the motor and 4T2 phases, otherwise User’s Manual.
against current unbalance. a short-circuit can occur.
D.85
ASTATplus
Basic diagram with linear ramp
Control voltage
110/120V AC

1
Control voltage
220/240V AC
Motorstarters

1r 2r 3r
Programmable relay outputs 3
Programmable inputs
I3 I4

Start Stop Motor thermistor


Push-button 2 Linear ramp 5
A
1 2 3 4 5
The isolation contactor In this example, Start The output relays allow The ASTATplus is provided with an electronic motor Linear ramp provided
DC1, is not required to and Stop command is for direct action on overload protection, which should be adequate by «Dxxx» function. A
B perform operation to
the motor. Be aware
enabled by
push-buttons.
contactors according
ratings specified.
protection for most of the applications.
Use an external overload protection if required by
tacho generator must
be used as feedback.
however that DC1 Permanet command is local codes or to protect the motor against current
provides galvanic allowed as well, unbalance. Linear ramp function
isolation from the wiring 1, 2 The linear ramp
C incoming line
increasing the safety.
and 57 terminals
accordingly.
function may be ena-
bled by setting «Dxxx»
to ON. In this case,
linear ramp is
independent of the
D load. This function
needs the speed
feedback provided
by an external tacho
generator.
E For more information,
check with ASTATplus
User’s Manual.

D.86
ASTATplus
Fuses, contactors and supply wiring
IEC Class 10 ratings
Type In Total Fuses Fuses Fuses Control voltage Contactor Conductor
losses aM Jean Müller Type BUSSMANN DC 1 DC 3 section
100% In (F1) Type (Typower Sicu 660V~) Fuse Consumption (2)
A W A Size In A VA mm2

Soft starters up to 850 kW


QC _ F DP 17 67 25 S00C+/üf01/40A/690V 00 40 1 18 CL02 CL02 4
QC _ G DP 21 78 32 S00C+/üf01/50A/690V 00 50 1 18 CL03 CL03 4
QC _ H DP 27 88 40 S00C+/üf01/80A/690V 00 80 1 18 CL04 CL03 6
QC _ I DP 38 116 63 S1üf01/110/100A/690V 00 100 1 18 CL45 CL04 10
QC _ J DP 58 208 80 S1üf01/110/125A/690V 00 125 2 55 CL07 CL45 16
QC _ K DP 75 277 100 S1üf01/110/160A/690V 00 160 2 55 CL08 CL06 25
QC _ L DP 86 302 125 S1üf01/110/200A/690V 00 200 2 55 CL09 CL06 35
QC _ M DP 126 389 200 S1üf01/110/250A/690V 00 250 2 55 CK75 CL07 50
QC _ N DP 187 719 250 M2üf02/315A/690V 00 315 2 78 CK08 CL10 95
QC _ Q DP 288 1097 400 M3üf02/500A/690V 2 550 2 78 CK95 CK85 185
QC _ R DP 378 1286 500 S3üf02/110/630A/690V 2 630 4 118 CK10 CK85 240
QC _ S DP 444 1374 630 S3üf02/110/800A/690V 2 800 4 118 CK11 CK95 Busbar (1)
QC _ T DP 570 2086 800 S3üf02/110/1000A/690V 3 1000 4 118 CK12 CK10 Busbar (1)
QC _ U DP 732 2352 1000 S3üf02/110/1250A/690V 3 1250 4 248 CK12 CK10 Busbar (1)
QC _ V DP 1020 3000 1250 S3üf02/110/800A/690V - - 4 248 CK13 CK11 Busbar (1)
QC _ X DP 1290 3839 2x800 S3üf02/110/1000A/690V - - 4 248 CK13 CK12 Busbar (1)

IEC Class 20 ratings


Type In Total Fuses Fuses Fuses Control voltage Contactor Conductor
losses aM Jean Müller Type BUSSMANN DC 1 DC 3 section
100% In (F1) Type (Typower Sicu 660V~) Fuse Consumption (2) A
A W A Size In A VA mm2
QC _ F DP 14 56 20 S00C+/üf01/40A/690V 00 40 1 18 CL01 CL01 4
QC _ G DP 17 65 25 S00C+/üf01/50A/690V 00 50 1 18 CL02 CL02 4
QC _ H DP 22 74 32 S00C+/üf01/80A/690V 00 80 1 18 CL03 CL03 4 B
QC _ I DP 32 99 63 S1üf01/110/100A/690V 00 100 1 18 CL04 CL04 6
QC _ J DP 48 178 80 S1üf01/110/125A/690V 00 125 2 55 CL06 CL04 10
QC _ K DP 63 236 80 S1üf01/110/160A/690V 00 160 2 55 CL07 CL04 16
QC _ L DP 72 257 100 S1üf01/110/200A/690V 00 200 2 55 CL08 CL06 25 C
QC _ M DP 105 325 160 S1üf01/110/250A/690V 00 250 2 55 CL10 CL06 35
QC _ N DP 156 591 200 M2üf02/315A/690V 00 315 2 78 CK75 CL07 70
QC _ Q DP 240 901 315 M3üf02/500A/690V 2 550 2 78 CK85 CK75 120
QC _ R DP 315 1063 400 S3üf02/110/630A/690V 2 630 4 118 CK95 CK85 185 D
QC _ S DP 370 1136 500 S3üf02/110/800A/690V 2 800 4 118 CK10 CK85 240
QC _ T DP 475 1721 630 S3üf02/110/1000A/690V 3 1000 4 118 CK11 CK95 Busbar (1)
QC _ U DP 610 1950 800 S3üf02/110/1250A/690V 3 1250 4 248 CK12 CK10 Busbar (1)
QC _ V DP 850 2491 1000 S3üf02/110/800A/690V - - 4 248 CK13 CK10 Busbar (1) E
QC _ X DP 1075 3168 1250 S3üf02/110/1000A/690V - - 4 248 CK13 CK12 Busbar (1)
(1) The DC1 contactor has to be selected for motors with nominal current equal to In (3) As IEC 947
(2) The 3 contacts of DC3 must be connected in parallel
F
Branch circuit protection, UL
Gould-Shawmut, semi-conductor fuses Max. circuit Shortcircuit rating max. @480V
Type Type Type Max. fuse breaker
Size
Non- Comments
Comentarios G
A50QS (3) A50P (4) rating class combination Combination
RK5 & J
(3) Suitable for use on a circuit
QC _ F DP 50A - 30A 35A 25kA 5kA capable of delivering not more
QC _ G DP 60A - 35A 40A 25kA 5kA than 100kA RMS symetrical H
QC _ H DP 80A - 40A 50A 25kA 5kA amperes, for 208V, 240V and
QC _ I DP 100A - 70A 80A 25kA 5kA up to 480V maximum, when
QC _ J DP 150A - 100A 125A 25kA 10kA used with the semi-conductor
fuse for shortcircuit protection.
QC _ K DP 200A - 125A 150A 25kA 10kA Listed with Gould Shawmut I
QC _ L DP 225A - 150A 150A 25kA 10kA Form 101, type A5Qs or A50P
QC _ M DP 350A - 200A 250A 25kA 10kA
(4) Suitable for use on a circuit
QC _ N DP 450A - 350A 350A 65kA 25kA
capable of delivering not more
QC _ Q DP 600A
QC _ R DP 2X500A in parallel
-
-
500A
600A
600A
700A
65kA
65kA
25kA
25kA
than 65kA RMS symetrical X
amperes, for 208V, 240V and
QC _ S DP 2x600A in parallel - 600A 800A 65kA 25kA up to 480V maximum, when
2
QC _ T DP - 2x1000A in parallel - 800A 65kA 30kA * used with contactors (isolation
QC _ U DP - 2x1200A in parallel - 1000A 65kA 30kA *
2 or by-pass) that are also rated
for 65kA withstand
QC _ V DP - 2x1600A in parallel - 1200A 65kA 65kA
Note: When ASTAT Plus reduced voltage starters are used in conjunction with semi-conductor fuses, type 2 coordination to IEC 947-4 is attained. These fuses
are recommended for best overall shortcircuit protection. The semi-conductor fuse specified may provide branch circuit protection. Refer to local applicable
electrical codes.

D.87
ASTATplus
Dimensional drawings
Soft starters for 3ph motors up to 850 kW

Type A B C Weight (kg)


. . QC _ FDP 200 160 6 4.3
QC _ GDP 200 160 6 4.3
QC _ HDP 200 160 6 4.6
QC _ I DP 250 200 31 4.6
Dimensions in mm
Motorstarters

. .

Type Weight (kg)


. . QC _ JDP 12.5
QC _ KDP 12.5
A Dimensions in mm

D
. .

E . .

F
Type Weight (kg)
. .
QC _ LDP 17
.
G QC _ MDP 17
Dimensions in mm

X
.
. .
. .

D.88
ASTATplus

Soft starters up to 850 kW


A
Terminals

B
Type A B C D E F G H I J K L Weight (kg)
QC _ NDP 510 490 305 460 465 9 53 106 54 259 70 168 45
QC_ QDP
QC _ RDP
510
550
490
540
305
317
460
480
465
495
9
9
53
59
106
118
54
54
259
275
70
78
168
168
45
45
C
QC _ SDP 550 540 317 480 495 9 59 118 54 275 78 168 45
QC _ TDP 590 685 317 520 640 9 59 118 64.5 270 100 168 80
QC _ UDP 790 850 402 700 805 11 60 120 120 352 120 175 80
QC _ VDP 790 850 402 700 805 11 60 120 120 352 120 175 80 D
QC _ XDP 810 1000 407 720 995 11 70 140 110 357 120 175 80

E
Terminals

.
F
.
.

. .
G

H
Type Type Type Type A Type
QC _ NDP QC _ NDP QC _ TDP QS _ UDP 6 QC _ XDP
QC _ QDP QC _ QDP QS _ VDP 10
I

Dimensions in mm X

D.89
Everything is
Control and signalling units

Series P9
E.2 Control and signalling units Ø 22 mm

Series 077
E.48 Control and signalling units Ø 30 mm

Series NLT
E.76 Light towers
Plug-in relays and Auxiliary contactors A
E.82 Palm push-buttons
Motor protection devices B
E.84 Foot switches
Contactors and Thermal overload relays C
E.86 Safety foot switches
Motorstarters D
E.87 Signalling devices
Control and signalling units E

Electronic relays F

Limit switches G

Speed drive units H

Main switches I

Numerical index X

under control E.1


Series P9
Control and signalling units Ø 22 mm

E.3 Main features

E.4 Range overview

E.6 Technical data

E.8 Catalogue number structure

E.9 Order codes - Panel mounting devices


E.10 Complete devices
E.13 Standard push-buttons
E.13 Mushroom head push-buttons
E.13 Push buttons with key
E.14 Selector switches with knob
A E.15 Selector switches with lever
E.16 Selector switches with key
E.18 Illuminated push-buttons
E.18 Illuminated selector switches
B E.19 Selector push-buttons
E.19 Toggle switches - Joysticks
E.20 Emergency lever
C E.20 Reset push buttons
E.20 Potentiometer operators
E.20 Buzzers - Pilot lights
E.21 Double function push-buttons
D E.22 Contact blocks
E.23 Power supplies
E.24 Electrical diagrams
E Control and signalling units

E.25 Order codes - Base mounting devices


F E.25 Standard push-buttons
E.25 Illuminated push-buttons
E.25 Pilot lights
G E.26 Selector switches
E.26 Electrical diagrams
E.27 Contact blocks and power supplies

H E.28 Order codes - Push-button stations in thermoplastic


E.30 Order codes - Equipped boxes
E.32 Order codes - Push-button stations in aluminium
I E.34 Order codes - Common accessories

E.40 Overall dimensions


X E.40 Panel mounting
E.45 Base mounting
E.47 Enclosures for push-button stations

E.2
Series P9
Main features

Control and signalling units Ø 22 mm


Shape, material and colours Fast mounting

The P9 line offers three types of operators: All the P9 rear panel devices are snap-on.
• round in satin chrome Mounting between panel and operator is accomplished by
• round in engineering thermoplastic means of a patented snap-on flange which ensures a fast
• square in engineering thermoplastic fitting.
Modern ergonomic P9 actuators are available in a wide For base mounting, the fitting is done directly on the adap-
variety of colours and styles, and are the result of superior tor inside the enclosures base.
industrial design experience.
Each single block can be mounted or removed individually.
Series P9 satisfies any sophisticated industrial applications.
In panel mounting, it is also possible to install or remove
the snap-on mounting flange with the contact block group;

Fitting and positioning Blocks and/or flange can be disassembled by a standard A


screwdriver, to simplify operations.

Safety and reliability


B

D
All the P9 operators are fitted with seal to ensure IP66 degree
of protection.
A locating tab on the operator allows the correct positioning The P9 contact blocks are designed to ensure maximum E
on panels with holes drilled reliability in every condition and to monitor control circuits
according to CENELEC EN 50007 standards (with notch). at low energy levels
The tab also ensures panel stability and prevents urwanted (12V-5mA) minimum), thanks to advanced solution such as:
rotations. • four contact points
F
The tab can be removed with a screwdriver for applications in • high efficiency self-cleaning operation
holes without notch. • silver contacts properly shaped
• high contact pressure G
Rear locking and Mounting system
back mounting procedure H

I
The P9 line offers a wide
variety of operators,
contact blocks and X
power supplies for
panel mounting.
Furthermore a range of operators, contact blocks and power
P9 operators are back mounted to the panel by a patented supplies are available for base mounting.
locking ring. The units can be assembled using a standard The base mounting option is simple thanks to plastic enclo-
screwdriver. sures fitted with a standard mounting adaptor, which allows
As an option, an assembly wrench is available. a snap-on and secure fastening.

E.3
Series P9

Panel
Control and signalling units Ø 22 mm

Control units
mounting
devices Standard push-b. Mushroom Emergency Key Knob selector Lever selector
push-b. push-b. push-b. sw. sw.

E.13 E.13 E.13 E.13 E.14 E.15

Key selector sw. Selector push-b. Toggle switch Joystick Emergency Double push-b.
lever

E.16 E.19 E.19 E.19 E.19 E.21

A
Contact blocks

B
E.22

C
Base Illuminated Signalling
Control units control units units
D mounting
devices Standard Musgroom Emergency p.-b. Illum. push-b. Pilot lights
push-b. push-b.

E
E.25 E.25 E.25 E.25 E.25

F Knob selector Key selector sw.


+ +
sw.
Power supplies

G
E.26 E.26 E.27

H
+
I
+ +
X
Enclosures
Contact blocks
+

E..27 E.28

E.4
Series P9

Illuminated control units Signalling units Others units


Illum. push-b. Illum. mushr. Pilot light Pilot light Reset push-b.
p.-b. unibloc

E.18 E.18 E.20 E.20 E.20

Illum. selector Double push- Potentiometer


sw. butt. op.

Range overview
E.18 E.21 E.20

+ Buzzer Panelmounting

Power supplies

E.20
E.23

+ or in enclosure A
Contact blocks

B
E.22 E.28

C
Accessories
General Push-buttons Mushroom Selector
push-buttons switches
Illuminated Illuminated
push-buttons mushroom
Illuminated
selector
Pilot lights
D
push-buttons switches
Nameplates Caps Name Knobs Diffusers Lenses Lenses Diffusers
plates E
E.38 E.34 E.39 E.36 E.35 E.36 E.36 E.35
Plugs Rubber Mushr. Levers Lenses Collar Padlock Lenses F
caps heads

E.37
E.37 E.36 E.36 E.36 E.36 E.37 E.36 G
Flanges Double Collar Padlock
rubber Ø 40
caps
E.37 E.37
H
E.21 E.37
Ring wrench Padlock Push-on/
push-off
device
I
E.37 E.37 E.37
Neutral plate Push-on/
push-off
Bulbs BA9S X
device
E.39 E.37 E.38
Keys Bulb extractor

E.38 E.37

E.5
Series P9
Technical data
Control and signalling units Ø 22 mm

Compliance with standards Electrical shocks protection (acc. IEC 536)


Metal operators Class I
IEC 947.5.1 - VDE 0660 - NFC 63140 Plastic operators Class II
IEC/EN 60947.5.1 - UTE - BSI - NEMA (double insulation)
CENELEC EN 50007

Short-circuit protection
Approvals
With fuses 16A gG according to IEC 269.1 and 269.3.
UL (U.S.A) - CSA (Canada) - RINA
Lloyd’s Register of Shipping - Bureau Veritas
Performances of the contacts
Climatic protections • Slow acting
The standard versions are suitable for use in the following climates: • Self-cleaning sliding
Temperate climate cat. 23/50 (DIN 50014) • NC forced breaking
Wet climate cat. 23/83 (DIN 50015) • Double movable bridge
Hot wet climate cat. 40/92 (DIN 50015) • Four switching points
Variable wet climate FW24 (DIN 50016)
• Double break

Temperature ranges Electrical resistance of the contact


Operation -25 °C to + 70 °C
Storage -40 °C to + 70 °C ⭐ 25 m ⍀ according to IEC 255, cat. 3

A Protection degree of the operators Identification of the terminals


IP66 according to CENELEC EN 60529 when they are
According CENELEC EN 50013
mounted into enclosures with the same or a higher degree
B of protection.
Suitable for using into enclosures type NEMA Electrical performances
1-3-3R-3S-4-4X-12-13 according to UL 508. Rated thermal current Ith = 10 A
C Performances according IEC 947.5.1
Protection degree of the terminals Categorie AC 15
Voltage Ue (V) 24 48 60 110 220 380 500 600
IP2x according to CENELEC EN 60529. Current Ie (A) 10 10 10 6 3 2 1.5 1.2
D Categorie DC 13
Shock resistance (acc. to MIL 202 B method 202 A) Voltage Ue (V) 24 48 60 110 220 300
Current Ie (A) 2.5 1.4 1 0.55 0.27 0.2
1/2 sinusoid 11 ms:
E No damage or disassembling at 100 g for all devices, Performances according to CSA and UL
except for the illuminated operators with transformer 38 g. AC Heavy Duty (A600)
DC Standard Duty (Q300)
F Vibration resistance (according to IEC 68-2-6)
16 g with frequency range from 40 to 500 Hz and
Operating range
maximum shifting 0.75 mm (peak-to-peak).
G
Rated insulation voltage V

H 690V according to EN 60947.1 12


5 mA
Impulse withstand voltage
I 4 kV according to EN 60947.1

Insulation class
X
Groep C according VDE 0110

E.6
Series P9

Electrical endurance Number of electrical contacts


Flange
Alternative current 50/60 Hz cat. AC 15 standard optional
3 positions 5 positions
Ith
Standard push-buttons
Mushroom head push-buttons max 6 max 8
Emergency lever
600V 220V 110V48/24V
1 Standard selectors max 4 max 8
Millions of ope-

0.5 Key selector switches


Joysticks
Key push-buttons max 4 -
0.1 Selector push-buttons
0.05 Toggle switches

Technical data
Mushroom head with lock max 2 -
Mushroom head push-buttons 3 pos.
0.01
01 05 1 5 10 Illuminated push-buttons
Current (A) Illuminated mushroom head push-buttons max 4 max 4
Illuminated selector switches
Illuminated mush. push-buttons with lock max 2 max 2
Direct current cat. DC 13 Illuminated mush. push-buttons 3 pos.

Ith
Mounting
220V 110V 48V 24V Fitted for panels 1 to 6 mm. thick with holes drilled accord-
1
Millions of ope-

0.5 ing to CENELEC EN 50007 standards. A


3.2 22.5
0.1 .125" .88"

B
23.5
.93"

0.05

flange with 3 positions


30mm
50mm
1.97"

0.01 1.18"
01 05 1 5 10
Current (A)
C
50mm
flange with 5 positions
1.97"

Mechanical endurance
Locking emergency D
Mushroom head push-buttons 3 positions 0.3 Mil./op.
Illuminated mushroom head push-buttons 3 pos.
Joysticks
Key push-buttons
0.5 Mil./op.
E
Toggle switches
Illuminated selector switches
Push-on push-off device
Standard selector switches
Key selector switches
F
Illuminated push-buttons 1 Mil./op
Selector push-buttons
Emergency lever
Standard push-buttons 3 Mil./op.
G
Mushroom head push-buttons

Rear panel modularity H


The P9 series is composed with 10 mm or a multiple of 10 mm
modular units, fitted side by side on a proper mounting flange.
The standard operators are supplied with a three position I
flange with a capacity of 3 units of 10 mm or 1 of 10 mm and
1 of 20 mm or 1 of 30 mm.
When the three position flange is not enough to satisfy the
applications needs, the five position flange is required to add
X
two more units of 10 mm mounted side by side.
Using the five position flange take into account the bigger
with (50 mm instead of 30 mm).

E.7
Series P9
Catalogue number structure
Control and signalling units Ø 22 mm

Standard & illuminated P9 P


push-buttons
Style Type Type Cap colour Push-button Lens type
type
M = Round satin P = Push N = Non 0= No cap G = Flush D = Diffused
chrome button illuminated N = Black S = Extended for
X = Round plastic L = Illuminated R = Red E = Recessed illumin.
S = Square plastic V= Green push
G= Yellow button
L= Blue only
B= White
M= Brown
H= Grey

Double function push-buttons P9 D P L

Style Type Type Cap colour Push-button ISO


type symbols
P = Push L = Illuminated V = Green G = Flush 00 = No sym.
button N = Black S = Top flush 01 = With
bottom sym.
extended

A Pilot lights P9

Style Type Colour Lens type For Unibloc


B type only
M = Round satin L = Standard R = Red D = Diffused D0 = Full
chrome U = Unibloc V = Green R = Refraced voltage
X = Round plastic G= Yellow V = Glass RN = With
C S = Square plastic L= Blue resistor
B= White
I = Clear
D A= Orange

Mushroom head push-buttons P9 E


E Style Type Mushroom Colour (1) Illumination Key selection
diameter
M = Round satin M = Momentary 3 = Ø 28 mm N= Black N = Non See key
F chrome T = Push/Pull 4 = Ø 40 mm R= Red illuminated selection
X = Round plastic R = Turn to 6 = Ø 60 mm V= Green L = Illuminated table on E.16
S = Square plastic reset G= Yellow
C = Key to
G reset

(1) Square plastic


H only in red

E.8
Series P9
Catalogue number structure

Control and signalling units Ø 22 mm


Knob & lever selector switches P9 S

Style Type Type Cam Spring return Colour


M= Round satin M= Knob D, I or H 2/4Positions N=Black
chrome V = Lever = 2 positions 0 = Fixed R = Red
X = Round plastic L = Illuminated E, L, U or Z 5 = From right V = Green
S = Square plastic knob = 3 positions 3 Positions G = Yellow
A = Illuminated X = 4 positions 0 = Fixed L = Blue
lever Y or W 1 = From left
= 5 positions 5 = From right
3 = From left
& right

Key selector switches P9 S C

Style Type Cam Spring return Key removal Key selection


M = Round satin D, I or H 2/4 Positions See key
chrome = 2 positions 0 = Fixed selection
X = Round plastic E, L, U or Z 5 = From right table
S = Square plastic = 3 positions 3 Positions on E.16
X = 4 positions 0 = Fixed See key
1 = From left removal
5 = From right position A
3 = From left
& right
B
Contact blocks P9 B

Style Contacts Terminal type Contact type


0 1 = 1 NC V = Standard N = Normal
C
1 0 = 1 NO screw A = Early closing
1 1 = 1 NO + F = Faston R = Late opening
1 NC B = Base 3 = Time delay D
mounting 0,1 - 30s
screw 8 = Time delay
T = Time 10 - 180s
delay E
screw

Power supplies P9 P F
Style Type Style Terminal type Voltage
D = Full
voltage
N = Normal
D = Diode
V = Standard
screw
0 = Full
voltage
G
T = Transfo. L = Long F = Faston D = 24V
R = Resistor life B = Base J = 110-120V
L = Integrated T = Test mounting L = 125-127V H
Led M = Multi- screw N = 220-250V
function U = 380V
(contin. W= 415-440V
blinking) Y = 480-500V
I

E.9
Series P9
Complete devices
Control and signalling units Ø 22 mm

Description Contact- Power Cap Cat. no. Ref. no. Cat. no. Ref. no.
block supply colour Metal Plastic

Momentary push-buttons Standard flush 1 NO Black P9MPN53007 153007 P9XPN52007 152007


(head + contact block) Green P9MPN53006 153006 P9XPN52002 152002
White P9MPN53008 153008 P9XPN52008 152008
Yellow P9MPN53009 153009 P9XPN52009 152009
Blue P9MPN53010 153010 P9XPN52010 152010
1 NC Red P9MPN53011 153011 P9XPN52011 152011

Standard raised 1 NC Red P9MPN53061 153061 P9XPN52061 152061

1 NO Black P9MPN53012 153012 P9XPN52012 152012

Mushroom/Emergency Mushroom head momentary 1 NC Red Ø 40 P9MEM53111 153111 P9XEM52111 152111


push-buttons
(head + contact block)
Mushroom head momentary 1 NO Black Ø 40 P9MEM53112 153112 P9XEM52112 152112

A Mush.with latch pull to release 1 NC Red Ø 40 P9MET53121 153121 P9XET52121 152121


Mush.with latch turn to release P9MER53161 153161 P9XER52161 152161
Mush.with latch key to release P9MEC53130 153130 P9XEC52130 152130
(key 3095)
B Emergency with latch turn to
release (EN 418)
P9XER52170 152170

Knob selector switch 2 fixed positions 1 NO Black P9MSM53293 153293 P9XSM52293 152293
C (knob head + contact block) I 90° II

2 fixed positions 1 NO + 1NC Black P9MSM53392 153392 P9XSM52392 152392


I 90° II
D
3 fixed positions 0
2 NO Black P9MSM53391 153391 P9XSM52391 152321
I II
45° 45°

E
3 spring return pos. 1 NO + 1 NC Black P9MSM53393 153393 P9XSM52393 152393
0
I II
45° 45°

F
Knob selector switch 2 fixed positions 1 NO Key 3095 P9MSC53435 153435 P9XSC52435 152435
I 90° II
G (knob head + contact block)

2 fixed positions 1 NO + 1NC Key 3095 P9MSC53436 153436 P9XSC52436 152436


I 90° II

H
3 fixed positions 0
2 NO Key 3095 P9MSC53497 153497 P9XSC52497 152497
I II
45° 45°

I 3 spring return pos.


0
1 NO + 1 NC Key 3095 P9MSC53498 153498 P9XSC52498 152498
I II
45° 45°

E.10
Series P9
Complete devices
Description Contact- Power Cap Cat. no. Ref. no. Cat. no. Ref. no.
block supply colour Metal Plastic

Illuminated push-buttons Momentary flush (bulb not 1NO Green P9MPL53502 153501 P9XPL52502 152502
(Head + Standard full voltage included)
power supply+ contact blocks)
1 NC Red P9MPL53511 153511 P9XPL52511 152511

1NO 1NC Green P9MPL53514 153514 P9XPL52514 152514


Red P9MPL53515 153515 P9XPL52515 152515
White P9MPL53513 153513 P9XPL52513 152513

Panel mounting
Momentary raised 1NC Red P9MPL53561 153561 P9XPL52561 152561
(Bulb not included)

Momentary flush - 1 NO Green P9MPL53530 153530 P9XPL52530 152530


Integrated LED 24V AC/DC

Momentary flush - 1NC Red P9MPL53531 153531 P9XPL52531 152531


Integrated LED 24V AC/DC

Pilot lights Standard diffused lens- Green P9MLD53610 153610 P9XLD52610 152610 A
Full voltage Power supply Red P9MLD53611 153611 P9XLD52611 152611
White P9MLD53612 153612 P9XLD52612 152612
Blue P9MLD53613 153613 P9XLD52613 152613
Yellow P9MLD53614 153614 P9XLD52614 152614
Standard diffused lens- Green P9MLD53620 153623 P9XLD52620 152620 B
Integrated LED 24VAC/DC Red P9MLD53621 153621 P9XLD52621 152621
White P9MLD53622 153622 P9XLD52622 152622

C
Double functions Flush both caps 1 NO + 1NC Green-red P9DPL54700 154700
push-buttons
(Head + contact block & power
supply when indicated) Flush both caps - 1 NO + 1NC Green-red P9DPL54720 154720 D
Full voltage power supply

Flush both caps with ISO I/O 1 NO + 1NC Green-red P9DPL54701 154701
Full voltage power supply E
Flush both caps with ISO I/O 1 NO + 1NC Green-red P9DPL54721 154721

E.11
Series P9
Notes
Control and signalling units Ø 22 mm

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

E.12
Series P9
Push-buttons
Standard / Momentary Description Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no.
see bottom see bottom see bottom
Metal Plastic Plastic

With flush cap P9MPN!G P9XPN!G P9SPN!G


With raised cap P9MPN!S P9XPN!S P9SPN!S
Recessed P9MPN!E

Mushroom head / Momentary


Mushroom head Ø 28 mm P9MEM3!N P9XEM3!N
Mushroom head Ø 40 mm P9MEM4!N P9XEM4!N
Mushroom head Ø 60 mm P9MEM6!N P9XEM6!N
Mushroom head 9 30 mm P9SEM3R 186031

Panel mounting
Mushroom head /
Emergency with latch
Standard Push-pull Mushroom head Ø40 mm P9MET4!N1 P9XET4!N1 P9SET4R 186061
to release

Push-twist Red mushroom head Ø28 mm P9MER3RN 184070 P9XER3RN 185070


to release Red mushroom head Ø40 mm P9MER4RN 184071 P9XER4RN 185071

Push-key Red mushroom head Ø40 mm P9MEC4RN1 P9XEC4RN1


to release A
Positive break Push-twist Red mushroom head Ø40 mm P9XER4RA 185072 P9SER4RA 186072
in accordance to release
with EN 418 B
Push-key Red mushroom head Ø40 mm P9XEC4RA1 P9SEC4RA95 186073
to release
C

Mushroom head / 3 positions


Ø40 mm 1-0 fixed. 2 transient P9MET4!N2 P9XET4!N2
D
Ø40 mm 0 fixed. 1-2 transient P9MET4!N3 P9XET4!N3

E
With keylock (1)
Key withdrawable normal P9MPCN1K1 P9XPCN1K1
in position I & II depressed
normal & depressed
P9MPCN2K1
P9MPCN3K1
P9XPCN2K1
P9XPCN3K1 F
Locking

G
Key withdrawable Lockable normal P9MPCN1E1 P9XPCN1E1
position III position depressed
normal & depressed
P9MPCN2E1
P9MPCN3E1
P9XPCN2E1
P9XPCN3E1 H
Locking

I
(1) Keys on E.16 The catalogue numbers in bold are available from stock.

Colours
X
black red green yellow brown blue white grey without
Caps ● N R V G M L B H 0
Mushroom heads ● N R V G - L - - -

Remark: To complete the catalogue number, For reference numbers,


substitute the symbol ● by a letterfor the choise of the colour
see chapter X, pg. X.10
and the symbol ▲ by a number for the type of the key.

E.13

32764_E01_E21_E_.indd 13 12-07-2005 11:17:48


Series P9
Selector switches with knob
Control and signalling units Ø 22 mm

2 positions Function (1) Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no.
see bottom see bottom see bottom
Metal Plastic Plastic

Fixed D P9MSMD0! P9XSMD0! P9SSMD0! (2) �

I P9MSMI0! P9XSMI0! P9SSMI0N 186120

H P9MSMH0! P9XSMH0!

With D P9MSMD5! P9XSMD5! P9SSMD5N 186140


spring return
I P9MSMI5! P9XSMI5! P9SSMI5N 186150

H P9MSMH1! P9XSMH1!

3 positions
E P9MSME0! P9XSME0! P9SSME0N 186170
Fixed L P9MSML0! P9XSML0!
U P9MSMU0! P9XSMU0! P9SSMU0N 186190
Z, B P9MSMZ0! P9XSMZ0! P9SSMZ0! (2) �

A With E P9MSME1! P9XSME1! P9SSME1N 186210


spring return L P9MSML1! P9XSML1!
U P9MSMU! P9XSMU1! P9SSMU1N 186230
Z;B P9MSMZ1! P9XSMZ1! P9SSMZ1N 186240
B E P9MSME5! P9XSME5!
L P9MSML5! P9XSML5!
U P9MSMU5! P9XSMU5!
Z, B P9MSMZ5! P9XSMZ5! P9SSMZ5N 186280
C E P9MSME3! P9XSME3!
L P9MSML3! P9XSML3!
U P9MSMU3! P9XSMU3!
Z, B P9MSMZ3! P9XSMZ3! P9SSMZ3N 186320
D

E 4 positions

Fixed
X P9MSMX0! P9XSMX0! P9SSMX0N 186330

F
With
spring return X P9MSMX5! P9XSMX5!

5 positions
H
Fixed X P9MSMY0! P9XSMY0!

W P9MSMW0! P9XSMW0! P9SSMW0N 186360


I

(1) Electrical diagrams, see E.24 The catalogue numbers in bold are available from stock.
X
Colours round shape black red green yellow blue
Knobs ● N R V G L
(2) P9SSMD0, P9SSMZ0 in square shape are available in all colours

For reference numbers,


see chapter X, pg. X.10

E.14

32764_E01_E21_E_.indd 14 12-07-2005 11:17:51


Series P9
Selector switches with lever
2 positions Function (1) Cat. no. Ref. no. Cat. no. Ref. no.
see bottom see bottom
Metal Plastic

Fixed D P9MSVD0! P9XSVD0!

I P9MSVI0! P9XaSVI0!

H P9MSVH0! P9XSVH0!

D P9MSVD5! P9XSVD5!
With

Panel mounting
spring return
I P9MSVI5! P9XSVI5!

H P9MSVH1! P9XSVH1!

3 positions
E P9MSVE0! P9XSVE0!
Fixed L P9MSVL0! P9XSVL0!
U P9MSVU0! P9XSVU0!
Z, B P9MSVZ0! P9XSVZ0!

With E P9MSVE1! P9XSVE1!


A
spring return L P9MSVL1! P9XSVL1!
U P9MSVU1! P9XSVU1!
Z;B P9MSVZ1! P9XSVZ1!

E P9MSVE5! P9XSVE5!
B
L P9MSVL5! P9XSVL5!
U P9MSVU5! P9XSVU5!
Z, B P9MSVZ5! P9XSVZ5!

E P9MSVE3! P9XSVE3!
C
L P9MSVL3! P9XSVL3!
U P9MSVU3! P9XSVU3!
Z, B P9MSVZ3! P9XSVZ3!
D
4 positions

Fixed
X P9MSVX0! P9XSVX0! E
With
spring return
X P9MSVX5! P9XSVX5! F

5 positions H
Fixed X P9MSVY0! P9XSVY0!

W P9MSVW0! P9XSVW0!
I

(1) Electrical diagrams, see E.24 The catalogue numbers in bold are available from stock.
X
Colours black red green yellow blue
Levers ● N R V G L

For reference numbers,


see chapter X, pg. X.10

E.15

32764_E01_E21_E_.indd 15 12-07-2005 11:17:52


Series P9
Selector switches with key
Control and signalling units Ø 22 mm

2 positions Function (1) Key Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no.
removal see bottom see bottom see bo-
Metal Plastic Plastic (1)

Fixed
D I P9MSCD0A1 P9XSCD0A1 P9SSCD0A95 186400
II P9MSCD0E1 P9XSCD0E1
I-II P9MSCD0K1 P9XSCD0K1 P9SSCD0K95 186402

I 0 P9MSCI0C1 P9XSCI0C1 P9SSCI0C95 186403


I P9MSCI0E1 P9XSCI0E1
0-I P9MSCI0N1 P9XSCI0N1 P9SSCI0N95 186405

H I P9MSCH0A1 P9XSCH0A1
0 P9MSCH0C1 P9XSCH0C1
I-0 P9MSCH0H1 P9XSCH0H1

With D I P9MSCD5A1 P9XSCD5A1 P9SSCD5A95 186409


spring return
I 0 P9MSCI5C1 P9XSCI5C1 P9SSCI5C95 186410

H 0 P9MSCH1C1 P9XSCH1C1

3 positions
A Fixed
E
0
I P9MSCE0A1
P9MSCE0C1
P9XSCE0A1
P9XSCE0C1
II P9MSCE0E1 P9XSCE0E1
I-0 P9MSCE0H1 P9XSCE0H1
I-II P9MSCE0K1 P9XSCE0K1
B 0-II
I-0-II
P9MSCE0N1
P9MSCE0T1
P9XSCE0N1
P9XSCE0T1

L I P9MSCL0A1 P9XSCL0A1
0 P9MSCL0C1 P9XSCL0C1
C I-0
II P9MSCL0E1
P9MSCL0H1
P9XSCL0E1
P9XSCL0H1
I-II P9MSCL0K1 P9XSCL0K1
0-II P9MSCL0N1 P9XSCL0N1
I-0-II P9MSCL0T1 P9XSCL0T1
D U I P9MSCU0A1 P9XSCU0A1
0 P9MSCU0C1 P9XSCU0C1
II P9MSCU0E1 P9XSCU0E1
I-0 P9MSCU0H1 P9XSCU0H1
E I-II
0-II
P9MSCU0K1
P9MSCU0N1
P9XSCU0K1
P9XSCU0N1
I-0-II P9MSCU0T1 P9XSCU0T1

Z, B I P9MSCZ0A1 P9XSCZ0A1
F 0
II
P9MSCZ0C1
P9MSCZ0E1
P9XSCZ0C1
P9XSCZ0E1
I-0 P9MSCZ0H1 P9XSCZ0H1
I-II P9MSCZ0K1 P9XSCZ0K1
0-II P9MSCZ0N1 P9XSCZ0N1
G I-0-II P9MSCZ0T1 P9XSCZ0T1 P9SSCZ0T95 186439

(1) Electrical diagrams, see E.24 The catalogue numbers in bold are available from stock.

H Keys for round shape


Standard version number 1 95
Standard version with 1 01 02 03 04 05 10 16 19 55
specific number (Ronis)
I
FIAT version number 1 33 34 37 38 40
Colour yellow black red blue orange

X (1) Key for square shape only standard version 95

For reference numbers,


see chapter X, pg. X.10

E.16

32764_E01_E21_E_.indd 16 12-07-2005 11:17:54


Series P9
Selector switches with key
3 positions Function (1) Key Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no.
removal see bottom see bottom see bottom
Metal Plastic Plastic (1)

With E 0 P9MSCE1C1 P9XSCE1C1


spring return II P9MSCE1E1 P9XSCE1E1
0-II P9MSCE1N1 P9XSCE1N1

L 0 P9MSCL1C1 P9XSCL1C1
II P9MSCL1E1 P9XSCL1E1
0-II P9MSCL1N1 P9XSCL1N1

U 0 P9MSCU1C1 P9XSCU1C1
II P9MSCU1E1 P9XSCU1E1

Panel mounting
0-II P9MSCU1N1 P9XSCU1N1

Z; B 0 P9MSCZ1C1 P9XSCZ1C1
II P9MSCZ1E1 P9XSCZ1E1
0-II P9MSCZ1N1 P9XSCZ1N1

E I P9MSCE5A1 P9XSCE5A1
0 P9MSCE5C1 P9XSCE5C1
I-0 P9MSCE5H1 P9XSCE5H1

L I P9MSCL5A1 P9XSCL5A1
0 P9MSCL5C1 P9XSCL5C1
I-0 P9MSCL5H1 P9XSCL5H1

U I P9MSCU5A1 P9XSCU5A1
0
I-0
P9MSCU5C1
P9MSCU5H1
P9XSCU5C1
P9XSCU5H1 A
Z, B I P9MSCZ5A1 P9XSCZ5A1 P9SSCZ5A95 186461
0 P9MSCZ5C1 P9XSCZ5C1
I-0 P9MSCZ5H1 P9XSCZ5H1
B
E 0 P9MSCE3C1 P9XSCE3C1
L 0 P9MSCL3C1 P9XSCL3C1
U 0 P9MSCU3C1 P9XSCU3C1
Z, B 0 P9MSCZ3C1 P9XSCZ3C1 P9SSCZ3C95 186467
C
4 positions
X I P9MSCX0A1 P9XSCX0A1
Fixed II P9MSCX0B1 P9XSCX0B1
III
IV
P9MSCX0D1
P9MSCX0E1
P9XSCX0D1
P9XSCX0E1
D
I-II P9MSCX0F1 P9XSCX0F1
I-III P9MSCX0J1 P9XSCX0J1
I-IV P9MSCX0K1 P9XSCX0K1
II-III
II-IV
P9MSCX0L1
P9MSCX0M1
P9XSCX0L1
P9XSCX0M1
E
III-IV P9MSCX0P1 P9XSCX0P1
I-II-III P9MSCX0R1 P9XSCX0R1
I-II-IV P9MSCX0S1 P9XSCX0S1
I-III-IV
II-III-IV
P9MSCX0U1
P9MSCX0V1
P9XSCX0U1
P9XSCX0V1
F
I-II-III-IV P9MSCX0Z1 P9XSCX0Z1

With X I P9MSCX5A1 P9XSCX5A1


spring return II
III
P9MSCX5B1
P9MSCX5D1
P9XSCX5B1
P9XSCX5D1
G
I-II P9MSCX5F1 P9XSCX5F1
I-III P9MSCX5J1 P9XSCX5J1
II-III P9MSCX5L1 P9XSCX5L1
I-II-III P9MSCX5R1 P9XSCX5R1 H
(1) Electrical diagrams, see E.24 The catalogue numbers in bold are available from stock.

Keys for round shape I


Standard version number 1 95
Standard version with 1 01 02 03 04 05 10 16 19 55
specific number (Ronis)
X
FIAT version number 1 33 34 37 38 40
Colour yellow black red blue orange

(1) Key for square shape only standard version 95

For reference numbers,


see chapter X, pg. X.10

E.17

32764_E01_E21_E_.indd 17 12-07-2005 11:17:55


Series P9
Illuminated push-buttons
Control and signalling units Ø 22 mm

Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no.
see bottom see bottom see bottom
Metal Plastic Plastic

Standard / Momentary
With diffused lens: Flush P9MPL!GD P9XPL!GD P9SPL!GD
Raised P9MPL!SD P9XPL!SD P9SPL!SD
Recessed P9MPL!ED P9XPL!ED P9SPL!ED

Mushroom head / Momentary


Mushroom head Ø40 mm P9MEM4!L P9MEM4!L
Mushroom head 9 30 mm P9SEM3RL 186551

Mushroom head / With latch


Push-pull to release
Mushroom head Ø40 mm P9MET4!L1 P9XET4!L1 P9SET4RL1 186561

Mushroom head / 3 positions


With mushroom Ø40 mm

1-0 fixed, 2 transient P9MET4!L2 P9XET4!L2


0 transient, 1-2 fixed P9MET4!L3 P9XET4!L3

A Illuminated selector switches with knob


2 positions Function (1)
D P9MSLD0! P9XSLD0! P9SSLD0!
Fixed
B

C 3 positions
Z, B P9MSLZ0! P9XSLZ0! P9SSLZ0!
Fixed
Z, B P9MSLZ1! P9XSLZ1!
D
With Z, B P9MSLZ5! P9XSLZ5!
spring return

E Z, B P9MSLZ3! P9XSLZ3!

F Illuminated selector switches with lever


2 positions Function (1)
D P9MSAD0! P9XSAD0!
Fixed
G

H 3 positions
Z, B P9MSAZ0! P9XSAZ0!
Fixed
I With
spring return
Z, B P9MSAZ1! P9XSAZ1!

Z, B P9MSAZ5! P9XSAZ5!

X Z, B P9MSAZ3! P9XSAZ3!

(1) Electrical diagrams, see E.24 The catalogue numbers in bold are available from stock.
Colours red green yellow oran- blue white clear For reference numbers,
Lens ● R V G A L B I see chapter X, pg. X.10
Mushroomheads ● R V G A L B I
Knob/lever ● R V G A L B I
E.18

32764_E01_E21_E_.indd 18 12-07-2005 11:17:57


Series P9
Selector push-buttons (black coloured)
Function (1) Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no.
Metal Plastic Plastic

2 positions
201 P9MPS21G 184690
Fixed 231 P9MPS22G 184691
235 P9MPS23G 184692

3 positions

Panel mounting
301 P9MPS34G 184693
Fixed 323 P9MPS35G 184694

Toggle switches (black coloured)


2 positions
D P9MCD 184695 P9XCD 185695 P9SCD 186695
Fixed position

A
3 positions
B P9MCB 184696 P9XCB 185696 P9SCB 186696
Fixed position B
Transient B P9MCC 184697 P9XCC 185697 P9SCC 186697
to zero from one
position
C

Joysticks (black coloured) D


2 positions + central zero position (1)
fixed postions P9MMN2F 184700 P9XMN2F 185700
Without interlock transient positions P9MMN2T 184701 P9XMN2T 185701
1 transient - 3 fixed positions
1 fixed - 3 transient positions
P9MMN2A
P9MMN2B
184702
184703
P9XMN2A
P9XMN2B
185702
185703
E

With interlock fixed postions P9MMB2F 184710 P9XMB2F 185710


F
transient positions P9MMB2T 184711 P9XMB2T 185711
1 transient - 3 fixed positions P9MMB2A 184712 P9XMB2A 185712
1 fixed - 1 transient positions P9MMB2B 184713 P9XMB2B 185713
G
4 positions + central zero position (1)

Without interlock
fixed postions
transient positions
P9MMN4F
P9MMN4T
184720
184721
P9XMN4F
P9XMN4T
185720
185721 H

I
With interlock fixed postions P9MMB4F 184740 P9XMB4F 185740
transient positions P9MMB4T 184741 P9XMB4T 185741
X

(1) Electrical diagrams, see E.24 The catalogue numbers in bold are available from stock.

E.19

32764_E01_E21_E_.indd 19 12-07-2005 11:17:59


Series P9
Emergency lever
Control and signalling units Ø 22 mm

Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no.
Metal Plastic Plastic

Red lever P9MWR 184770 P9XWR 185770

Reset push-button
White symbol on blue background P9MRG 184771 P9XRG 185771 P9SRG 186771

Potentiometer operator (potentiometer not included)


Black knob P9MZ 184772 P9XZ 185772 P9SZ 186772

A
Buzzer
Black coloured
B Bitonal sound
Full voltage AC/DC
Frequency: 2kHz
Sound intensity: 80dB at 1 m
Consumption: 3 to 9 mA
C 24 V
110-240 V
P9XBD
P9XBM
185773
185774
P9SBD
P9SBM
186773
186774

D Pilot lights
Standard
Diffused lens (for filament bulb) P9ML!D see bottom P9XL!D see bottom P9SL!D see bottom
E Refracted lens (for neon bulb)
Glass lens
P9ML!R see bottom
P9ML!V see bottom
P9XL!R
P9XL!V
see bottom
see bottom

Unibloc (complete pilot light)


Full voltage AC/DC
F BA9S max 382 V - 2 W not included
Diffused lens P9XU!DD0 see bottom
Refracted lens P9XU!RD0 see bottom

With resistor 220 V


G BA9S 110 V - 2 W included
Diffused lens P9XU!DRN see bottom
Refracted lens P9XU!RRN see bottom

H The catalogue numbers in bold are available from stock.

Colours red green yellow orange blue white clear


Lens ● R V G A L B I
I

For reference numbers,


see chapter X, pg. X.10

E.20
Series P9
Double function push-buttons (1)
Colours (2) Cat. no. Ref. no. Cat. no. Ref. no.
Plastic caps Plastic caps
without symbols with symbols

IP40 protection (acc. to IEC 529)


With white lens assembled for inducator light.
Black insert for not illuminated function
included in the packaging.
A - Black P9DPLNRG00 186880 P9DPLNRG01 186890
B - Red

Panel mounting
• A flush
lens A - Green P9DPLVRG00 186881 P9DPLVRG01 186891
B - Red
• B flush

A - Black P9DPLNRS00 186882 P9DPLNRS01 186892


B - Red

• A flush
A - Green P9DPLVRS00 186883 P9DPLVRS01 186893
lens B - Red
• B raised

Clear cap (silicon rubber)


IP66 protection (acc. to IEC 529)
A
A - flush 080CPDT 173208 080CPDT 173208
B - flush

A - flush P9ADCST 187796 P9ADCST 187796


B
B - raised

C
(1) With white lens assembled.
Black insert for not illuminated function included in the packaging.
(2) Integral caps, colours not replacable.
D

E.21
Series P9
Contact blocks
Control and signalling units Ø 22 mm

Cat. no. Ref. no.

Logic Reed Contact type NC P9B01FH 187014


NO P9B10FH 187015
A new range of LOGIC REED Rated voltage AC2 to 120V max.
contact blocks with faston terminals DC2 to 30V max.
for use with power Rated current AC/DC - 0.001 to 0.15A max.
lower than 12V - 5mA. Rated power AC - 8VA max.
DC - 4.5W max.
Minimum centerline distance 30x32 mm.
Mounting on operators through specific bayonet flange adaptor. P9ACFSM 187846

Full voltage power supply P9PDHF 187056

With screw Contact type Cat. no. Ref. no.

min. 1 of 22 AWG (0.32 mm2)


max. 2 of 12 AWG (3.3 mm2)
NC+NO P9B11VN 187000

NC+NC P9B02VN 187008

A ----

NO+NO P9B20VN 187009

B ----

NC P9B01VN 187001

C
NO P9B10VN 187002

D
NC late opening P9B01VR 187003
E

NO early closing P9B10VA 187004


F

G NC+NO delayed 0.1-30 sec


10-180 sec
P9B11T3
P9B11T8
187010
187011

H Faston NC P9B01FN 187012

I 1 x (6.35 x 0.8 mm)


NO P9B10FN 187013
2 x (2.8 x 0.8 mm)

X
Terminal adapter NO P9ACA6 188804
printed circuit board
adapter

The catalogue numbers in bold are available from stock.

E.22

32764_E22_E47_E.indd 22 12-07-2005 12:03:15


Series P9
Power supplies
With screw Position on flange Contact type Cat. no. Ref. no.
2 3 1

min. 1 of 22 AWG (0.32 mm2)


max. 2 of 12 AWG (3.3 mm2)
Full voltage O P9PDNV0 187020
■■■ IEC: BA9S max 380V-2W not included
UL-CSA: BA9S max 250V-2W not included

Logic Reed fullvoltage for low power P9PDHF 187056

Long life 110/120V O P9PRLVJ 187021


■■■ BA9S 130V-2W included

Panel mounting
Resistor + Diode P9PRDVN 187022
220/240 V ^
■■■ BA9S 130V-2W included

Resistor P9PRNVJ 187023


110/120V O
BA9S 60V-1.2W included

220/240V O P9PRNVN 187024
BA9S 130V-2W included

Resistor ENEL version P9PREVJ 187025


BA9S 48V-2W included
■ 110V O A
125/127V O P9PREVL 187026

UL-CSA: BA9S max 250V-2W not included P9PDTV0 187027



Test full voltage (1) O
IEC: BA9S max 380V-2W not included
B
Test resistor (1) P9PRTVN 187028
220/240 V O
■ BA9S 130V-2W included C
Transformer 50/60 Hz P9PTNV♦ see bottom
BA9S 6V-1.5W included

Multifunction (2) full voltage 24V O
BA9S 24V-2W included
P9PDMVD 187040 D
Multifunction (2) full voltage 110V O P9PDMVJ 187041
BA9S 130V-2W included

Multifunction (2) P9PTMV♦ see bottom


E
Transformer 50/60 Hz
BA9S 6V-0.6W included

F
Faston ■■■ Full voltage P9PDNF0 187055
IEC:BA9S max 380V-2W not included
UL-CSA: BA9S max 250V-2W not included

1 x (6.35 x 0.8 mm)


2 x (2.8 x 0.8 mm)
G

Integrated LED Standard light


24V AC/DC P9PLNVD• see bottom H
120V AC P9PLNVJ• see bottom
x1
230V AC P9PLNVN• see bottom
■■■
Flashing light
x2 24V AC/DC P9PLFVD• see bottom I
120V AC P9PLFVJ• see bottom
230V AC P9PLFVJ• see bottom

(1)
X
LED orange white yellow blue red green
co- A B G L R V
The catalogue numbers in bold are available from stock.
(2) Do not connect for
flashing light
Voltage 110- 220-250 380 415-440 480-500 For reference numbers,
Link to external contact in
order to have steady or ♦ J N U W Y see chapter X, pg. X.10
flashing light
C closed = Steady light
C open = Flashing light
E.23

32764_E22_E47_E.indd 23 12-07-2005 12:03:17


Series P9
Diagrams Selector push-buttons
Control and signalling units Ø 22 mm

Selector switches Position


Positions Function Contacts Normal Depressed on flange
2 3 1
Position
Positions Function Contacts on flange B11
I 90 ° II
2 3 1 201
D B11 ■■■
I 90 ° II B10
■■■ Normal Depressed

B10 B11
D I 90 ° II
B01 ■■■ 231
B11 ■■■
Normal Depressed
D B11
■■■
I II B11
90 °
0
235
45 ° I B11
I B11 ■■■ ■■■
Normal Depressed
0
I 45 ° B11 II B11
H ■■■ I III
B11 45 ° 45 ° 301
B11 ■■■
0
I II B10 Normal Depressed
45 ° 45 ° B
A B10 ■■■
II B11
I III
45 ° 45 ° 323
0
I II
45 ° 45 ° B11 ■■■
E B11 ■■■
B Can not be depressed
0
I II
45 ° 45 ° L B11 ■■■ Joysticks
C
Position
0
I II U B11 Positions Contacts on flange
45 ° 45 °
2 3 1
D
1 0 3
B11 ■■■ B11

0 B11 ■■■
E I
45 ° 45 °
II Z B11
1 2 0 3 4

B11 B11
■■■
B11
F Z
B10
■■■
B01 ■■■
Toggle switches
G II III B11
Position
I 45° 45° 45° IV X Positions Function Contacts on flange
B11 ■■■ 2 3 1
H II III
D B11
■■■
B11
II III IV
40 ° 40 ° Y
I 40 ° 40 ° V
I B11 ■■■ B B11 ■■■

II III
B11 Mushroom head push-buttons 3 pos.
X II III IV
I °
40
40 ° 40 °
40 ° V
W
B11 ■■■ Position
FunctionContacts on flange
2 3 1
2 B01R
B01 ■■■

3 B11
■■■

E.24

32764_E22_E47_E.indd 24 12-07-2005 12:03:19


Series P9
Push-buttons
Description Cat. no. Ref. no.
Plastic

Standard / Momentary With flush cap P9YPN!G see bottom


With raised cap P9YPN!S see bottom

Mushroom head Red mushroom head Ø40 mm P9YEM4RN 185920


/Momentary Red mushroom head 9 30 mm

Base mounting
Mushroom head / Push-twist to release P9YER4RA 185921
Emergency with latch Red mushroom head Ø40 mm
in accordance with EN 418 standards

A
Illuminated push-buttons
Description Cat. no. Ref. no.
Plastic B

Standard / Momentary Diffused lens

Flush P9YPL!GD see bottom


C
Raised P9YPL!SD see bottom

E
Pilot lights
Description Cat. no. Ref. no.
Plastic F

Diffused lens P9YL!D


G

H
The catalogue numbers in bold are available from stock.

Colours black red green yellow orange brown blue white grey clear
I
Caps ● N R V G - M L B H -
Diffused lensen ● - R V G A - L B - I
X

For reference numbers,


see chapter X, pg. X.10

E.25
Series P9
Selector switches with knob (black coloured)
Control and signalling units Ø 22 mm

2-3 positions Function (1) Cat. no. Ref. no. Cat. no. Ref. no.
Plastic Plastic

D P9YSMD0N 185960 P9ZSMD0N 186960

Z, B P9YSMZ0N 185962 P9ZSMZ0N 186962

With Z, B P9YSMZ3N 185965 P9ZSMZ3N 186965


spring return

Selector switches with standard key


2 positions Function (1) Key Cat. no. Ref. no. Cat. no. Ref. no.
removal Plastic Plastic

Fixed D I P9YSCD0A95 185970 P9ZSCD0A95 186970


I-II P9YSCD0K95 185972 P9ZSCD0K95 186972

B
3 positions
Z, B 0 P9YSCZ0C95 185784 P9ZSCZ0C95 186975
Fixed I-0-II P9YSCZ0T95 185980 P9ZSCZ0T95 186980
C
With Z, B 0 P9YSCZ3C95 185987 P9ZSCZ3C95 186987
spring return
D

E
The catalogue numbers in bold are available from stock.

F
Diagrams

G Position
Positions Function Contact on flange
2 3 1

H I 90 ° II
D
P9 B10...
P9 B01...
■■■

I I
0
II P9 B10... ■■■
45 ° 45 ° B
P9 B10...

X
0
I II P9 B10... ■■■
45 ° 45 ° Z
P9 B01...

E.26

32764_E22_E47_E.indd 26 12-07-2005 12:03:22


Series P9
Contact blocks
With screw Contact type Cat. no. Ref. no.

min. 1 of 22 AWG (0.32 mm2) NC P9B01BN 187017


max. 2 of 12 AWG (3.3 mm2)

NCO P9B10BN 187018

Base mounting
Power supplies
With screw Position on flange Bulb power supply Cat. no. Ref. no.
2 3 1

min. 1 of 22 AWG (0.32 mm2)


max. 2 of 12 AWG (3.3 mm2)
Full voltage O P9PDNB0 187070
IEC: BA9S max 380V-2W not included
■■■ UL-CSA: BA9S max 250V-2W not included

Long life 110/120V O


BA9S 130V-2W included
P9PRLBJ 187071
A
■■■

Resistor + Diode P9PRDBN 187072


■■■ 220/240 V ^
BA9S 130V-2W included
B
Additional resistor
■■■ 110/120V O for BA9S 60V-1.2W
220/240V O for BA9S 130V-2W
P9PRNBJ
P9PRNBN
187073
187074 C

Integrated LED Standard light


x1 24V AC/DC
120V AC
P9PLNBD•
P9PLNBJ•
see bottom
see bottom
D
■■■ 230V AC P9PLNBN• see bottom
x2
E
The catalogue numbers in bold are available from stock.

LED orange white yellow blue red green F


colour• A B G L R V

For reference numbers,


see chapter X, pg. X.10

E.27

32764_E22_E47_E.indd 27 12-07-2005 12:03:22


Series P9
Push-button stations in thermoplastic (Light grey coloured RAL 7035)
Control and signalling units Ø 22 mm

For panel and base mounting


– IP66 according to IEC529, EN 60529
– Engineered thermoplastic covers, bases and screws
– Self extinguishing Class V0, according to UL 94
– Rust resistant (4X according to UL 508)
– Total insulation with all thermoplastic operators
– Contact blocks and power supplies for both base and front mounting

Empty versions Number of holes Cat. no. Ref. no.


1(yellow cover) P9EPEG1 189000
Cover with holes 1 P9EPE01 189001
Knockouts conduit entry 2 P9EPE02 189002
3 P9EPE03 189003
4 P9EPE04 189004
6 P9EPE06 189005

For panel mounting

Accessories Description Symbols Cat. no. Ref. no.


Without text P9AELN 189030
Write-on plates
Bilaminated, self adhesive, 20 x 20 mm Text in English (1) START P9AELN202 189031
Black background STOP P9AELN201 189032
A engravable for white texts FORWARD
REVERSE
P9AELN214
P9AELN215
189033
189034
CLOSE P9AELN205 189035
OPEN P9AELN206 189036
START STOP UP P9AELN204 189037
B DOWN
LEFT
P9AELN203
P9AELN222
189038
189152
RIGHT P9AELN224 189154

C P9AELN006 189041
C ➞ I 0
I P9AELN028
P9AELN029
189042
189043
II P9AELN035 189044
III P9AELN038 189045
0-I P9AELN039 189046
D I-0-II P9AELN042 189047

Earth terminal clamp P9AEMT 189029

Equipped versions Operators Colour Diagram Name- Cat. no. Ref. no.
E plate
One unit Flush push-button green I P9EPA01Y02 189010

Flush push-button white I P9EPA01Y03 189011


F
Flush push-button red 0 P9EPA01Y04 189012

G Flush push-button black 0 P9EPA01Y05 189013

Emergency push-button red 0 P9EPAG1Y01 189015


with latch according to
H EN418 (yellow cover)
Emergency push-button red 0 P9EPA01Y02 189144
with latch according to
EN418 (yellow cover)
Key selector switch with - 0-I P9EPA01Y06 189014
I 2 pcs. (Key code 95)

(1) Other languages on request The catalogue numbers in bold are available from stock.
X

E.28
Series P9
Push-button stations in thermoplastic (continued)
Equipped versions Operators Colour Diagram Name- Cat. no. Ref. no.
plate
Two units Flush push-buttons green I P9EPA02Y01 189016

red 0

Flush push-buttons white I P9EPA02Y02 189017

black 0

Push-button stations
Full voltage pilot light BA9S white blank P9EPA03Y01 189018
Three units max 380V-2W
not included

Flush push-buttons green I

red 0

Full voltage pilot light BA9S white blank P9EPA03Y02 189019


max380V-2W
not included

Flush push-buttons white I

black 0

Resistor + diode pilot light


220/240V AC
white blank P9EPA03Y03 189020 A
BA9S 130V-2W included

Flush push-buttons green I


B
red 0

Resistor + diode pilot light white blank P9EPA03Y04 189021


220/240V AC
BA9S 130V-2W included
C
Flush push-buttons white I

black 0
D
Flush push-buttons black B P9EPA03Y05 189022

red 0
E
black D
F
Flush push-buttons green I 189023
Six units P9EPA06Y01

red 0
G

black B
H
black D
I
black A

X
black C

The catalogue numbers in bold are available from stock.

E.29
Series P9
Equipped boxes
Control and signalling units Ø 22 mm

Specially enclosures to use for shaft lifts


(other versions, please contact us)

Composition Individual Cat. no. Ref. no. Pack


operators
One operator Thermoplastic box. 1 element P9EPE01 P9EPC01X00 215432 1
Emergency push button mushroom head Ø40, P9XET4RN1
push-pull to release
1NC contact block P9B01VN
1NO contact block P9B10VN
Nameplate with inscription “EMERGENCY-STOP” 080XTGR02
PG16 packing gland

Thermoplastic box. Yellow cover. 1 element P9EPEG1 P9EPC01X01 215433 1


Emergency push-button mushroom head Ø40, P9XER4RN
push-twist to release
1NC contact block P9B01VN
Nameplate with inscription “EMERGENCY-STOP” 080XTGR02

Two operators Thermoplastic box. 2 elements P9EPE02 P9EPL02X01 189136 1


Emergency push-button mushroom head Ø28, P9XER3RN
push-twist to release
1NC contact block P9B01VN
Nameplate with inscription “STOP” P9AELN201
16A Schuko socket-outlet with cover
A
Thermoplastic box. 2 elements P9EPE02 P9EPL02X02 189137 1
Selector switch, 2 positions, with red knob P9XSMD0R
B 1NC contact block
Nameplate with inscription “O-I”
P9B01VN
P9AELN039
16A Schuko socket-outlet with cover

C
Three operators Thermoplastic box. 3 elements P9EPE03 P9EPL03X01 189138 1
Selector switch, 2 positions, with black knob P9XSMD0N
D 1NC contact block
1NO contact block
P9B01VN
P9B10VN
Nameplate with inscription “LINEA” P9AELN523
Selector switch, 2 positions, with red lever P9XSVD0R
1NO contact block P9B10VN
E Nameplate with inscription “O-I”
16A Schuko socket-outlet with cover
P9AELN039

F Thermoplastic box. 3 elements


Selector switch, 2 positions, with black knob
P9EPE03
P9XSMD0N
P9EPL03X02 189138 1

1NC contact block P9B01VN


1NO contact block P8B10VN
Nameplate with inscription “LINEA” P9AELN523
G Emergency push-button mushroom head Ø28, push-
twist to release
P9XER3RN

1NC contact block P9B01VN


Nameplate with inscription “STOP” P9AELN201
16A Schuko socket-outlet with cover
H

I Thermoplastic box. 3 elements


Emergency push-button mushroom head Ø40,
P9EPE03
P9XER4RN
P9EPL03X03 189140 1

push-twist to release
1NC contact block P9B01VN
Nameplate with inscription “STOP” P9AELN201
X Round plug
16A Schuko socket-outlet with cover
P9ARHPR

E.30
Series P9
Equipped boxes (continued)
Specially enclosures to use for shaft lifts
(other versions, please contact us)

Composition Individual Cat. no. Ref. no. Pack


operators
Three operators Thermoplastic box. 3 elements P9EPE04 P9EPL04X01 189141 1
Selector switch, 2 positions, with black knob P9XSMD0N
1NC contact block P9B01VN
1NO contact block P9B10VN
Nameplate with “Light” symbol P9AELN100
Standard/momentary push button with flush cap, green P9XPNVG

Push-button stations
1NO contact block P9B10VN
Nameplate with “Bell” symbol P9AELN099
Emergency push-button mushroom head Ø28, push- P9XER3RN
twist to release P9B01VN
1NC contact block P9AELN201
Nameplate with inscription “STOP”
16A Schuko socket-outlet with cover

E.31
Series P9
Push-button stations in aluminium (Grey coloured RAL 7012)
Control and signalling units Ø 22 mm

For panel mounting Protection Number of holes Type Cat. no. Ref. no.
IP66 1 1 080SP1 170801
Cover with holes (according to 1 1M (1) 080SP1M 170831
with conduit entry IEC 529, EN 60529) 2 2 080SP2 170802
2 2M (1) 080SP2M 170832
3 3 080SP3 170803
4 4 080SP4 170804
4 4M (1) 080SP4M 170834
6 6 080SP6 170806
8 8 080SP8 170807
12 12 080SP12 170808
18 18 080SP18 170809
24 24 080SP24 170810
35 35 080SP35 170811

Cover with holes IP66 1 1 080SP1SFE 170836


without conduit entry (according to 1 1M (1) 080SP1MSFE 170839
IEC 529, EN 60529) 2 2 080SP2SFE 170842
2 2M (1) 080SP2MSFE 170845
3 3 080SP3SFE 170848
4 4 080SP4SFE 170850
4 4M (1) 080SP4MSFE 170851
6 6 080SP6SFE 170852
8 8 080SP8SFE 170854
12 12 080SP12SFE 170857
18 18 080SP18SFE 170860
24 24 080SP24SFE 170862
35 35 080SP35SFE 170864

Cover without holes IP66 1 080SP1SFC 170835


A with conduit entry (according to
IEC 529, EN 60529)
1M (1)
2
080SP1MSFC
080SP2SFC
170838
170841
2M (1) 080SP2MSFC 170844
3 080SP3SFC 170847
4 080SP2SFC 170841
B 4M (1)
6
080SP2MSFC
080SP3SFC
170844
170847
8 080SP8SFC 170853
12 080SP12SFC 170856
18 080SP18SFC 170859
C 24
35
080SP18SFC
080SP35SFC
170859
170863

Cover without holes IP66 1 080SP1SF 170837


D without conduit entry (according to
IEC 529, EN 60529)
1M (1)
2
080SP1MSF
080SP2SF
170840
170843
2M (1) 080SP2MSF 170846
3 080SP3SF 170849
4 080SP2SF 170843
E 4M (1)
6
080SP2MSF
080SP3SF
170846
170849
8 080SP8SF 170855
12 080SP12SF 170858
18 080SP18SF 170861
F 24
35
080SP18SF
080SP35SF
170861
170865

(1) With deep socle

G
Accessories
Description Cat. no. Ref. no.
Kit of two hinges for 080KCSP 170883
H types 18, 24, 35 with holes

Overall dimensions, see E.47 The catalogue numbers in bold are available from stock.

E.32
Series P9
Notes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Push-button stations
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

E.33
Series P9
Caps for standard push-buttons
Control and signalling units Ø 22 mm

Colour Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no.
Flush and recessed Raised Flush Raised

Neutral
P9ARBG ● 18710 ■ P9ARBS ● 18720 ■ P9ASBG ● 18750 ■ P9ASBS ● 18760 ■
With symbols (1)

Black P9ARBGN 029 187150 P9ARBSN 029 187250 P9ASBGN 029 187550 P9ASBSN 029 187650
Stop Red P9ARBGR 029 187110 P9ARBSR 029 187210 P9ASBGR 029 187510 P9ASBSR 029 187610

Black P9ARBGN 028 187111 P9ARBSN 028 187211 P9ASBGN 028 187511 P9ASBSN 028 187611
Start Green P9ARBGV 028 187112 P9ARBSV 028 187212 P9ASBGV 028 187512 P9ASBSV 028 187612
White P9ARBGB 028 187151 P9ARBSB 028 187251 P9ASBGB 028 187551 P9ASBSB 028 187651

Black P9ARBGN 035 187113 P9ARBSN 035 187213 P9ASBGN 035 187513 P9ASBSN 035 187613
Second function Green P9ARBGV 035 187114 P9ARBSV 035 187214 P9ASBGV 035 187514 P9ASBSV 035 187614

Black P9ARBGN 038 187115 P9ARBSN 038 187215 P9ASBGN 038 187515 P9ASBSN 038 187615
Third function Green P9ARBGV 038 187116 P9ARBSV 038 187216 P9ASBGV 038 187516 P9ASBSV 038 187616

Black P9ARBGN 006 187117 P9ARBSN 006 187217 P9ASBGN 006 187517 P9ASBSN 006 187617
Continuous rectilinear Green P9ARBGV 006 187118 P9ARBSV 006 187218 P9ASBGV 006 187518 P9ASBSV 006 187618
motion White P9ARBGB 006 187152 P9ARBSB 006 187252 P9ASBGB 006 187552 P9ASBSB 006 187652
Continuous rotation Black P9ARBGN 012 187119 P9ARBSN 012 187219 P9ASBGN 012 187519 P9ASBSN 012 187619
to the right Green P9ARBGV 012 187120 P9ARBSV 012 187220 P9ASBGV 012 187520 P9ASBSV 012 187620
A Continuous rotation Black P9ARBGN 013 187121 P9ARBSN 013 187221 P9ASBGN 013 187521 P9ASBSN 013 187621
to the left Green P9ARBGV 013 187122 P9ARBSV 013 187222 P9ASBGV 013 187522 P9ASBSV 013 187622

Feed Black P9ARBGN 014 187123 P9ARBSN 014 187223 P9ASBGN 014 18/7523 P9ASBSN 014 187623
B Green P9ARBGV 014 187124 P9ARBSV 014 187224 P9ASBGV 014 187524 P9ASBSV 014 187624

Increase Black P9ARBGN 017 187125 P9ARBSN 017 187225 P9ASBGN 017 187525 P9ASBSN 017 187625
Green P9ARBGV 017 187126 P9ARBSV 017 187226 P9ASBGV 017 187526 P9ASBSV 017 187626

C Decrease Black
Green
P9ARBGN 018 187127 P9ARBSN 018 187227 P9ASBGN 018 187527 P9ASBSN 018 187627
P9ARBGV 018 187128 P9ARBSV 018 187228 P9ASBGV 018 187528 P9ASBSV 018 187628

Auto cycle Black P9ARBGN 026 187129 P9ARBSN 026 187229 P9ASBGN 026 187529 P9ASBSN 026 187629
Green P9ARBGV 026 187130 P9ARBSV 026 187230 P9ASBGV 026 187530 P9ASBSV 026 187630
D Black P9ARBGN 027 187131 P9ARBSN 027 187231 P9ASBGN 027 187531 P9ASBSN 027 187631
Manual
Green P9ARBGV 027 187132 P9ARBSV 027 187232 P9ASBGV 027 187532 P9ASBSV 027 187632

Locking Black P9ARBGN 031 187133 P9ARBSN 031 187233 P9ASBGN 031 187533 P9ASBSN 031 187633
E Green P9ARBGV 031 187134 P9ARBSV 031 187234 P9ASBGV 031 187534 P9ASBSV 031 187634

Releasing Black P9ARBGN 032 187135 P9ARBSN 032 187235 P9ASBGN 032 187535 P9ASBSN 032 187635
Green P9ARBGV 032 187136 P9ARBSV 032 187236 P9ASBGV 032 187536 P9ASBSV 032 187636

F Coolant Black
Green
P9ARBGN 001 187137 P9ARBSN 001 187237 P9ASBGN 001 187537 P9ASBSN 001 187637
P9ARBGV 001 187138 P9ARBSV 001 187238 P9ASBGV 001 187538 P9ASBSV 001 187638

Light Black P9ARBGN 002 187139 P9ARBSN 002 187239 P9ASBGN 002 187539 P9ASBSN 002 187639
Green P9ARBGV 002 187140 P9ARBSV 002 187240 P9ASBGV 002 187540 P9ASBSV 002 187640
G Black P9ARBGN 005 187141 P9ARBSN 005 187241 P9ASBGN 005 187541 P9ASBSN 005 187641
Lubrication
Green P9ARBGV 005 187142 P9ARBSV 005 187242 P9ASBGV 005 187542 P9ASBSV 005 187642

Reset Blue P9ARBGL 037 187143 P9ASBGL 037 187543 P9ASBSL 037 187643
H Black P9ARBGN 036 187153 P9ASBGN 036 187553
Stop/Reset
Red P9ARBGR 036 187144 P9ASBGR 036 187544

Black P9ARBGN 030 187145 P9ARBSN 030 187245 P9ASBGN 030 187545 P9ASBSN 030 187645
I Test
Green P9ARBGV 030 187146 P9ARBSV 030 187246 P9ASBGV 030 187546 P9ASBSV 030 187646

Stop Red P9ARBGR 201 187147 P9ARBSR 201 187247 P9ASBGR 201 187547 P9ASBSR 201 187647

Black P9ARBGN 202 187148 P9ARBSN 202 187248 P9ASBGN 202 187548 P9ASBSN 202 187648
X Start Green P9ARBGV 202 187149 P9ARBSV 202 187249 P9ASBGV 202 187549 P9ASBSV 202 187649
White P9ARBGB 202 188909 P9ARBSB 202 188978 P9ASBGB 202 189859 P9ASBSB 202 189928

(1) Other symbols on request The catalogue numbers in bold are available from stock.

Colours black red green yellow brown blue white grey


Caps ● N R V G M L B H

E.34

32764_E22_E47_E.indd 34 12-07-2005 12:03:33


Series P9
Diffusers/insert for illuminated units
Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no.
For pilot lights For illuminated For pilot lights and
push buttons illuminated push buttons

Neutral
P9ARDLS 187300 P9ARDPL 187350 080QDF 173220

Common accessories
With symbols(1) on white
background

Stop P9ARDLS029 187301 P9ARDPL029 187351 080QDF029 187701

Start P9ARDLS028 187302 P9ARDPL028 187352 080QDF028 187702

Second function P9ARDLS035 187303 P9ARDPL035 187353 080QDF035 187703

Third function P9ARDLS038 187304 P9ARDPL038 187354 080QDF038 187704

Continuous rectilinear
P9ARDLS006 187305 P9ARDPL006 187355 080QDF006 187705
motion
Continuous rotation P9ARDLS012 187306 P9ARDPL012 187356 080QDF012 187706
to the right
Continuous rotation
to the left P9ARDLS013 187307 P9ARDPL013 187357 080QDF013 187707
A
Feed P9ARDLS014 187308 P9ARDPL014 187358 080QDF014 187708
B
Increase P9ARDLS017 187309 P9ARDPL017 187359 080QDF017 187709

Decrease P9ARDLS018 187310 P9ARDPL018 187360 080QDF018 187710 C


Auto cycle P9ARDLS026 187311 P9ARDPL026 187361 080QDF026 187711

Manual P9ARDLS027 187312 P9ARDPL027 187362 080QDF027 185788


D
Locking P9ARDLS031 187313 P9ARDPL031 187363 080QDF031 187713
E
Releasing P9ARDLS032 187314 P9ARDPL032 187364 080QDF032 187714

Coolant P9ARDLS001 187315 P9ARDPL001 187365 080QDF001 187715 F


Light P9ARDLS002 187316 P9ARDPL002 187366 080QDF002 187716

Lubrication P9ARDLS005 187317 P9ARDPL005 187367 080QDF005 187717


G

Test P9ARDLS030 187318 P9ARDPL030 187368 080QDF030 185789


H
Stop P9ARDLS201 187319 P9ARDPL201 187369 080QDF201 187719

Start P9ARDLS202 187320 P9ARDPL202 187370 080QDF202 187720 I

(1) Other symbols on request The catalogue numbers in bold are available from stock. X

E.35

32764_E22_E47_E.indd 35 12-07-2005 12:03:34


Series P9
Mushroom heads
Control and signalling units Ø 22 mm

Description Cat. no. Ref. no. Cat. no. Ref. no.


see bottom see bottom
Plastic Plastic

Momentary operators Ø 28 mm P9ARB3!


Ø 40 mm P9ARB4!
Ø 60 mm P9ARB6!
9 30 mm P9ASB3!

Push-pull operators Ø 40 mm P9ACB4! P9ACB4!

Knobs and levers


Description Cat. no. Ref. no. Cat. no. Ref. no.
see bottom see bottom
Plastic Plastic

Knob for selector switches P9ACMN! P9ACMN!

Lever for selector switches P9ARMV!

Lenses
A Description Cat. no. Ref. no.
see bottom
Cat. no. Ref. no.
see bottom
Plastic Plastic

B
Pilot lights diffused version P9ARGLD! P9ASGLD!
refracted version P9ARGLR!
glass version P9ARGLV!

C
Illuminated push-buttons diffused version P9ARGPD! P9ASGPD!

Illuminated mushroom head push-b. momentary Ø 40 mm P9ARGP4!


D 9 30 mm
push-pull Ø 40 mm P9ACGP4!

Illuminated selector switches knob P9ACGSL! P9ACGSL!


E lever P9ARGSA!

F Rubber protective caps (IP66)


Description Cat. no. Ref. no. Cat. no. Ref. no.
see bottom see bottom
Plastic Plastic
G
Standard flush push-buttons coloured (nitrilic rubber) 080CP! P9ASCG!
clear (silicon rubber) 080CPT 170198 P9ASCGT 170790
H
Raised push buttons clear (silicon rubber) P9ARCST 187490 P9ASCST 187791
I
The catalogue numbers in bold are available from stock.

Colours black red green yellow orange blue white clear


X Mushroom heads ● N R V G - L - -
Knobs/lever ● N R V G - L - -
Lenses ● - R V G A L B I
Protective caps ● N R V G - - - -

For reference numbers,


see chapter X, pg. X.10

E.36
Series P9
Common accessories
Plugs Description Cat. no. Ref. no. Cat. no. Ref. no.
Plastic Plastic

Round P9ARHPR 187491


Square 30 x 30 mm P9ASHP3 187792
Rectangular 30 x 50 mm P9ASHP5 187793

Common accessories
Protections
Collar for mushroom head push-buttons Ø40 mm. P9ARRE4 187492

Protection cover P9ACRCL 187840 P9ACRCL 187840


padlockable for standard push-buttons,
illuminated push-buttons, selector switches,
illuminated selector switches with knob.

Flanges
With three positions Centre distances 30 x 50 mm P9ACFS3 187841 P9ACFS3 187841

With five positons Centre distances 50 x 50 mm P9ACFS5 187842 P9ACFS5 187842

A
With two positons For Logic Reed contact blocks P9ACFSM 187846 P9ACFSM 187846

Adapter screw plug-in terminal


Only for Logic Reed contact blocks and power supplies P9ACAFV 187847 P9ACAFV 187847 B

Adapter C
Gives round control and signalling units a square appearance. P9ARSN1 188805
Made in black thermoplastic.
Can be used with nameplate for square operators P9ASTBS
(see P.30).
Excluded for mushroom flush buttons with positive break D
and types with 3 positions.

Push-on/push off
Device for standard push-buttons and illuminated push-buttons. P9ACDPP 187843 P9ACDPP 187843
E
To be added only to single pole contact blocks.
The NO-contacts must be early closing types.

Extended srew G
For reset push-buttons (setting min. 80, max. 170 mm) P9ACVLR 187844 P9ACVLR 187844

H
Central contact driving plug
For standard momentary push-buttons and momentary P9ASHAC 187794
mushroom head push-buttons.
I
Tools
Locking ring wrench P9ACWAF 187845 P9ACWAF 187845 X
Bulb extractor 080ESL 170212 080ESL 170212

Extractor for caps and lenses P9ASEBG 187795

The catalogue numbers in bold are available from stock.

E.37
Series P9
Spare keys
Control and signalling units Ø 22 mm

Description Cat. no. Ref. no.


Plastic

Standard version Code

3095 077C3095 173095


9901 077C9901 173901
9902 077C9902 173902
9903 077C9903 173903
9904 077C9904 173904
9905 077C9905 173905
9910 077C9910 173910
9916 077C9916 173916
9919 077C9919 173919
3353 077C3353 173353
(Ronis) 455 077CR455 173455

FIAT version Colour Code

yellow 73033 077CF73033 173033


black 73034 077CF73034 173034
red 73037 077CF73037 173037
blue 73038 077CF73038 173038
orange 73040 077CF73040 173040

Bulbs BA9s
Description Cat. no. Ref. no.
A Plastic

Filament type Vn Vn
B 6 0.6 BA9S606 187850
6 1.5 BA9S615 187851
12 2.0 BA9S122 187852
24 2.0 BA9S242 187853
C 30 2.1 BA9S30 187854
48 2.0 BA9S48 187855
60 1.2 BA9S6012 187856
130 2.0 BA9S130 187857

D Neon type 110 0.11 BA9SN110 187860


220 0.33 BA9SN220 187861

Mono LED VN AC/DC ± 10%

E 6 BA9S6L! see bottom


12 BA9S12L! see bottom
24 BA9S24L! see bottom
48 BA9S48L! see bottom
110 BA9S110L! see bottom
F (AC) 230 BA9S230L! see bottom

Colours red green yellow blue white


G ● R V G L B

Insert holders
H Description Cat. no. Ref. no. Cat. no. Ref. no.
Plastic Plastic

I Supplied with neutral insert engravable


on both sides or transparent.

Standard 30 x 50 mm Background black/red, white text P9ARTBS 188000 P9ASTBS 188010


Background white, black text P9ARTWS 188005 P9ASTWS 188011
X Transparent P9ARTTS 188012 P9ASTTS 188014

Extended 45 x 50 mm Background black/red, white text P9ARTBM 188001


Background white, black text P9ARTWM 188008
Transparent P9ARTTM 188019

The catalogue numbers in bold are available from stock.


For reference numbers,
see chapter X, pg. X.10

E.38
Series P9
Rectangular inserts
For insert holders 30 x 50 mm Neutral
Description Cat. no. Ref. no. Description Cat. no. Ref. no.

black/red background P9ACPBS 188015


white background P9ACPWS 188017
transparent P9ACPTS 188018

English (1) French (1)


black background START P9ACPBS202 188202 black background MARCHE P9ACPBS308 188308
STOP P9ACPBS201 188201 ARRET P9ACPBS301 188301
FORWARD P9ACPBS214 188214 AVANT P9ACPBS303 188303

Push-button stations
START REVERSE P9ACPBS215 188215 ARRIERE P9ACPBS302 188302
CLOSE P9ACPBS205 188205 FERMER P9ACPBS309 188309
OPEN P9ACPBS206 188206 OUVRIR P9ACPBS316 188316
UP P9ACPBS204 188204 MONTEE P9ACPBS317 188317
DOWN P9ACPBS203 188203 DESCENTE P9ACPBS304 188304
LEFT P9ACPBS222 188222 GAUCHE P9ACPBS306 188306
RIGHT P9ACPBS224 188224 DROITE P9ACPBS305 188305
FAST P9ACPBS208 188208 VITE P9ACPBS324 188324
SLOW P9ACPBS207 188207 LENT P9ACPBS307 188307
OPEN-CLOSE P9ACPBS234 188234 OUVERT-FERME P9ACPBS335 188335
HAND-AUTO P9ACPBS243 188243 MAIN-AUTO P9ACPBS336 188336
STOP-START P9ACPBS232 188232 ARRET-MARCHE P9ACPBS328 188328
MARCHE FORWARD-REVERSE P9ACPBS231 188231 AVANT-ARRIERE P9ACPBS332 188332
OFF-ON P9ACPBS233 188233 HORS-EN P9ACPBS331 188331
AUTO-OFF-HAND P9ACPBS258 188258 AUTO-0-MAIN P9ACPBS334 188334
FORWARD-0-REVERSE P9ACPBS239 188239 AVANT-0-ARRIERE P9ACPBS333 188333
0-1 P9ACPBS039 188030 0-1 P9ACPBS039 188030

For insert holders 45 x 50 mm Neutral


black/red background, white text
white background, black text
P9ARPBM
P9ARPWM
188002
188028 A
transparent P9ARPTM 188019

Round plates for emergency B


Diameter 59 mm Diameter 78 mm
Description Cat. no. Ref. no. Description Cat. no. Ref. no.

Without text yellow background 080XTGR 179514 black background 080XTG8 179515
C
With text yellow background black background
EMERGENZA 080XTGR01 179525 EMERGENZA 080XTG801 179535
EMERGENCY STOP
ARRET D’URGENCE
080XTGR02
080XTGR03
179526
179510
EMERGENCY STOP
ARRET D’URGENCE
080XTG802
080XTG803
179536
179511
D
NOT - AUS 080XTGR04 179527 NOT - AUS 080XTG804 179537
NOODSTOP 080XTGR05 179528 NOODSTOP 080XTG805 179538
PARO EMERGENCIA 080XTGR06 179529 PARO EMERGENCIA 080XTG806 179539
NOTSTOP
PARAGEM EMERGÈNCIA
080XTGR07
080XTGR08
179530
179531
EMERGENZA GENERALE
PARAGEM EMERGÈNCIA
080XTG807
080XTG808
179540
179541
E
59 mm 78 mm

F
Neutral plate
Description Cat. no. Ref. no.
Snap-on system For identification of contact P9ACPIU 188016 G
blocks and power supplies

H
(1) Other languages on request. The catalogue numbers in bold are available from stock.

E.39
Series P9
Dimensional drawings
Control and signalling units Ø 22 mm

Round operators - Push-buttons


P9MPN–G P9MPN–S P9MPN–E P9MEM3–N P9MEM4–N P9MEM6–N
P9XPN–G P9XPN–S P9XEM3–N P9XEM4–N P9XEM6–N
P9MER3RN P9MER4RN
P9XER3RN P9XER4RN
P9MEC4RN–

P9MET4–N– P9XER4RA P9XEC4RA– P9MPCN– – –


P9XET4–N– P9XPCN– – –

A
Round operators - Selector switches
B P9MSM– – – P9MSV– – – P9MSC– – – –
P9XSM– – – P9XSV– – – P9XSC– – – –

E Round operators - Illuminated push-buttons and selector switches


P9MPL– G – P9MPL– S – P9MPL– E – P9MEM4–L P9MET4–L– P9MSL– – –
P9XPL– G – P9XPL– S – P9XPL– E – P9XEM4–L P9XET4–L– P9XSL– – –
F P9MSA – – –
P9XSA – – –

I Round operators - Pilot lights


P9ML– – P9ML–V P9XU– –
P9XL– –
X
Ø 28

14 49. 5

E.40

32764_E22_E47_E.indd 40 12-07-2005 13:44:11


Series P9

Round operators - Other devices


P9MPS– – – P9MC– P9MPN–E P9MMN– – P9MMB– –
P9XC– P9XMN– – P9XMB– –

Panel mounting
P9MRG P9MZ P9MPS– – –
P9XRG P9XZ

* with accessory P9ACVLR A

Square operators - Push-buttons


P9SPN–S
B
P9SPN–G P9SEM3–N

P9SET4–N– P9SER4RA P9SEC4RA– E

Square operators - Double function push-buttons


H
P9DPL– –G– – P9DPL– –S– –

E.41

32764_E22_E47_E.indd 41 12-07-2005 13:44:12


Series P9
Dimensional drawings
Control and signalling units Ø 22 mm

Square operators - Selector switches Square operators - Pilot lights


P9SSM– – – P9SSC– – – – P9SL–D

Square operators - Illuminated push-buttons and selector switches


P9SPL–GD P9SPL–SD P9SPL–ED P9SEM3–L P9SET4–L– P9SSL– – –

A Square operators - Other devices


Toggle switch Reset push-button

B P9SC– P9SRG

E Potentiometer operator Buzzer Adaptor

P9SZ P9SB– P9ARSN1

E.42

32764_E22_E47_E.indd 42 12-07-2005 13:44:13


Series P9

Contact blocks
P9B01V– / P9B01FN /

Panel mounting
P9B011VN / P9B02VN / P9B20VN P9B11T–

A
Power supplies
P9PDNV0 / P9PRLV– / P9PRDV– P9PDNF0 B

E
P9PRNV– / P9PDTV0 / P9PRTV– P9PREV–

H
P9PTNV– P9PDMV– /

E.43

32764_E22_E47_E.indd 43 12-07-2005 13:44:14


Series P9
Dimensional drawings
Control and signalling units Ø 22 mm

Push-on / push-off devices Protection cover


P9ACDPP P9ACRCL

Insert holders and plates


P9ARTBS P9ARTBM P9ASTBS
P9ARTWS P9ARTWM P9ASTWS
P9ARTTS P9ARTTM P9ASTTS

C 080XTGR– – 080XTG8– –

E.44

32764_E22_E47_E.indd 44 12-07-2005 13:44:15


Series P9

Round operators - Push-buttons


P9YPN–G P9YPN–S P9YEM4RN P9YER4RA

Base mounting
Round operators - Selector switches Round operators - Illuminated push-buttons
P9YSM– –N P9YSC– – – – P9YPL–GD P9YPL–SD

Round operators - Pilot lights A


P9YL–D

Square operators - Push-buttons


P9ZPN–G P9ZM3RN
D
P9ZPN–S P9ZER4RA

Square operators - Selector switches Square operators - Illuminated push-buttons


G
P9ZSM– –N P9ZSC– – – – P9ZPL–GD P9ZPL–SD

Square operators - Pilot lights X


P9ZL–D

E.45

32764_E22_E47_E.indd 45 12-07-2005 13:44:16


Series P9
Dimensional drawings
Control and signalling units Ø 22 mm

Contact blocks
P9B01BN
P9B10BN

(1) With insert holder


(2) Without insert holder

Power supplies
P9PDNBO P9PRNBJ
P9PRLBJ P9PRNBN
P9PRDBN

E.46

32764_E22_E47_E.indd 46 12-07-2005 13:44:16


Series P9
Overall dimensions
Enclosures for push-button stations in thermoplastic
72
E1
E1 (Knock-outs on top
(Knock-outs on
and Holes A B C E1 E2 H
top bottom)
and bottom) 57 1 72 46 16.5 23(1) 15.5 57
2 110 78 16.5 23(1) 21.5 95
3 140 108 16.5 23(1) 21.5 125
L(3) 4 175 143 16.5 23(1) 21.5 160
6 235 200 19.5 29(2) 23 220

Push-button stations
B H A (1) Suitable for cable gland, with locknut,
PG16 or 1/2” NPT
53.5 (2) Suitable for cable gland, with locknut,
PG21 or 3/4” NPT
C (3) Flush push-button: 13
Pilot light: 14
Emergency push-button: 50
E2 (Two
E2 (Two knock-outs
knock-outs on 4 4fixing
fixingholes
holes Key selector switch: 22
on the rear)
the rear) ØØ4.3mm
4,3mm For customized versions see operator dimensions.

Enclosures for push-button stations in aluminium


C
B D Fixing holes

1 2 A
Ømax
H
A 50
4 3 B
30 L

F
C
E

D
Holes Ø 22 Dimensions Fixing templates
Type vertic. horizont. A B C D E F HxLxØmax position
(mm) (mm) (mm) (mm) (mm) (mm) of the

1 1 – 87 87 75 72 21.5 PG 21 74x55x4
holes
1-3
E
1M 1 – 87 87 100 97 21.5 PG 21 68x55x4 1-3
2 2 – 145 87 75 72 21.5 PG 21 132x55x4 1-3
2M 2 – 145 87 100 97 21.5 PG 21 126x55x4 1-3
3
4
3
2

2
195
145
87
87
100
75
97
72
21.5
21.5
PG 21
PG 21
176x55x4
132x55x4
1-3
1-3
F
4M 2 2 145 87 100 97 21.5 PG 21 126x55x4 1-3
6 3 2 195 87 100 97 21.5 PG 21 176x55x4 1-3
8 2 4 152 152 101.5 98.5 27 PG 29 136x119x6 1-3
12
18
3
3
4
6
205
257
230
300
101.5
101.5
98.5
98.5
27
35
PG 29
PG 36
172x214x6
221x282x6
1-2-3-4
1-2-3-4
G
24 4 6 257 300 101.5 98.5 35 PG 36 221x282x6 1-2-3-4
35 5 7 350 350 123 106.5 41 PG 36 180x180x10 1-2-3-4

E.47
Series 077
Technical data
Compliance with standards Performances of the contacts
IEC 947.5.1 - VDE 0660 - NFC 63140 • Slow acting
CEI EN 60947.5.1 - UTE - BSI - NEMA • Self-cleaning
Control and signalling units

CENELEC EN 50007 • NC forced breaking


• Double break
Approvals
UL (U.S.A.) - CSA (Canada) - RINA - Lloyd’s Register of Shipping Electrical performances
Rated thermal current Ith = 10 A
Climatic protections Performances according IEC 947.5.1
The standard versions are suitable for use in the following climates: Categorie AC 15 (A600)
Temperate climate cat. 23/50 (DIN 50014) Voltage Ue (V) 24 48 60 110 220 380 500 600
Wet climate cat. 23/83 (DIN 50015) Current Ie (A) 10 10 10 6 3 2 1.5 1.2
Hot wet climate cat. 40/92 (DIN 50015) Categorie DC 13 (P600)
Variable wet climate FW24 (DIN 50016) Voltage Ue (V) 24 48 60 110 220 300 500 600
Currente Ie (A) 5 2.7 2 1.1 0.55 0.3 0.22 0.2
Categorie DC 13 (Q300) for illuminated push-buttons and
Temperature ranges illuminated selector switch
Voltage Ue (V) 24 48 60 110 220 300
Currente Ie (A) 2.5 1.1 1 0.55 0.27 0.2
Operation -25 °C to + 70 °C
Storage -40 °C to + 70 °C
Performances according to CSA and UL
A Protection degree of the operators AC Heavy Duty (A600)
DC Standard Duty (Q300) for illuminated push-buttons and
illuminated selector switch
IP65 according to IEC 529 when they are mounted into
B enclosures with the same or a higher degree of protection.
IP66 with appropriate protective caps. Electrical endurance
Protection degree of the terminals Alternative current 50/60 Hz cat. AC 15
C
IP2x according to IEC 529. Ith
Fully integrated on signalling units, illuminated
D push-buttons and illuminated selector switches. With
1
600V 220V 110V48/24V
Millions of ope-

accessory on contact blocks for control units.


0.5

Rated insulation voltage


E 0.1
690V according to EN 60947.1 0.05

Impulse withstand voltage


F 0.01
01 05 1 5 10

4 kV according to EN 60947.1 Current (A)

G Insulation class Direct current cat. DC 13

Group C according to VDE 0110 Ith

H Electric shocks protection 220V 110V 48V 24V


1
Millions of ope-

0.5
Class I according to IEC 536
I
Short-circuit protection 0.1

0.05

With fuses type gl of 10A according to IEC 947.5.1


X 0.01
01 05 1 5 10
Connection terminals Current (A)

Connection terminals
Screw type with retractable clamp.
Clamping capacity of rigid and/or flexible conductors:
- minimum 22 AWG (0.32 mm2)
- maximum 12 AWG (3.3 mm2)

E.48
Series 077

Control and signalling units Ø 30 mm


Mechanical endurance Fitting of units
Joysticks The units of Series 077 are designed for fitting onto panels
Key push-buttons 0.5 x 106 op. with a thickness between 1 and
Locking emergency 7 mm., with holes of 30.5 mm. diameter, according to rules
Knob selector switches established by EN 60947.5.1.
Lever selector switches
A special metal ring supplied with each unit or one of the
Key selector switches
1 x 106 op.
name plates included among the fittings, enables the unit
Illuminated selector switches
Selector push-buttons to be exactly positioned.
Timed push-buttons All equipment is supplied with a set of spacing rings to
Illuminated push-buttons adjust variations in the thickness of the panel thus ensuring
Momentary std push-buttons a uniform front protrusion.
3 x 106 op.
Momentary mush. push-buttons For a correct fitting, it needs to observe the diagram below
and tables indications.
Number of contact blocks
Momentary standard push-buttons 4 double pole
Momentary mush. push-buttons (8 single pole)
Key push-buttons 4 double pole
Locking emergency (4 single pole)
Selector switches 6 double pole
(4 pos. types excl) (6 single pole)
4 pos. selector switches 2 double pole
Selector push-buttons 6 double pole
(6 single pole)
A
Joysticks 2 and 4 double pole
4 positions (4 single pole)
Illuminated push-buttons
Illuminated selector
For different contacts
configuration, contact
B
switches our sales office
Remark
The codes of the units shown on this catalogue, identify C
complete units.
On request we can supply the operator only
(for push-buttons, selector pushbuttons, selector switches, D
joysticks).
In this case make code replacing the suffix 077 with 0770
omitting the identification numbers of the contact block.
e.g. 077SCD1109 becomes 0770SCD09. E

E.49

32764_E48_E81_E.indd 49 12-07-2005 15:17:16


Series 077
Push-buttons
Standard/Momentary Description Contacts Cat. no. Ref. no.
NC+NO 077P11 180019
NC 077P01 180039
NO 077P10 180029
Control and signalling units

Standard/Time delayed (1)


Contacts delayed at the release of
the push button.
Accuracy ± 5%
Setting range: 0,1 - 30 sec. NC+NO 077P11T30 180120
10 - 180 sec. NC+NO 077P11T180 180121

To complete by Fixing kits


With 4 coloured caps: Ring type
black, red, green, yellow with guard 077GGBCN 180020
without guard 077GSBCN 180010
extended guard 077GEBCN 180030

With 4 coloured caps:


brown, orange, blue, white Ring type
A with guard
without guard
077GGBCS
077GSBCS
180050
180040
extended guard 077GEBCS 180060

B With 1 clear and 4 marking etched


on both sides Ring type
with guard 077GGBCF 180137
without guard 077GSBCF 180136
MARCIA
extended guard 077GEBCF 180138
C ARRESTO

Standard/Momentary
D (complete types)
Ring type
with guard NC+NO 077P!11G see bottom
without guard NC+NO 077P!11S see bottom
E

G
(1) Not approved by RINA and The catalogue numbers in bold are available from stock.
Lloyd’s Register

H Colours black red green


● N R V

For reference numbers,


see chapter X, pg. X.12

E.50
Series 077
Push-buttons

Control and signalling units Ø 30 mm


Mushroom head/Momentary Description Contacts Cat. no. Ref. no.
NC+NO 077E11 180049
NC 077E01 180069
NO 077E10 180059

Mushroom head/ Emergency


with latch
Push-twist to release NC+NO 077RE11 180079
NC 077RE01 180099
NO 077RE10 180089

With keylock (3)


Key withdrawable in positions I & II
Locking Lockable in position:
normal NC+NO 077PC11E 180101
depressed NC+NO 077PC11F 180102
normal & depressed NC+NO 077PC11C 180100
(type G unlock) depressed without pre-setting(2) NC+NO 077PC11G 180104

Key withdrawable in positions II


A
Lockable in position:
Locking normal NC+NO 077PC11EH 200255
depressed NC+NO 077PC11FH 215248
NC+NO 077PC11CH 212677
normal & depressed
depressed with pre-setting(1) NC+NO 077PC11DH 200254 B
Description Diameter Cat. no. Ref. no.
To complete by Mushroom head caps
C
For momentary push-buttonl Ø 35 mm 077E! see bottom
Ø 60 mm 077EE! see bottom

For push-twist
to release push-button
Red Ø 35 mm 077RER 180090
D
For keylock push-button Red Ø 60 mm 077ECR 181602

Colours black red green yellow F


● N R V G

(1) Pre-setting operation: turn the key in position II and remove it.
(2) Combined with mushroom head 077ECR makes an emergency with G
latch push-key to release.
(3) Supplied with two standard keys 3095.

The catalogue numbers in bold are available from stock. H

For reference numbers,


see chapter X, pg. X.12

E.51

32764_E48_E81_E.indd 51 12-07-2005 15:17:17


Series 077
Selector switches with knob
2 positions Function Contacts Cat. no. Ref. no.
(1) (2) see bottom
D NC+NO 077SD!11
Fixed
I NC+NO 077SIN11 180200
Control and signalling units

H NC+NO 077SHN11 180180

With I NC+NO 077SIN11DC 180210


spring return
H NC+NO 077SHN11SC 180190

3 positions
B NC+NO 077SB!11
Fixed E NC+NO 077SEN11 180270
U 2NC+2NO 077SUN22 180440
Z 2NC+2NO 077SZN22 180480

With B NC+NO 077SBN11SC 180240


spring return E NC+NO 077SEN11SC 180280
U 2NC+2NO 077SUN22SC 180450
Z 2NC+2NO 077SZN22SC 180490

B NC+NO 077SBN11DC 180250


E NC+NO 077SEN11DC 180290
U 2NC+2NO 077SUN22DC 180460
A Z 2NC+2NO 077SZN22DC 180500

B NC+NO 077SBN11RC 180260


E NC+NO 077SEN11RC 180300
U 2NC+2NO 077SUN22RC 180470
B Z 2NC+2NO 077SZN22RC 180510

4 positions
C Fixed
X 2NC+2NO 077SX!22

D
(1) Electrical diagrams, see E.69 The catalogue numbers in bold are available from stock.
E
Colours black red green yellow
(2)
N R V G
F

(2) Only for function D, B and X


fixed position

For reference numbers,


see chapter X, pg. X.12

E.52

32764_E48_E81_E.indd 52 12-07-2005 15:17:18


Series 077
Selector switches with lever

Control and signalling units Ø 30 mm


2 positions Function (1) Contacts Cat. no. Ref. no.
Metal
Fixed D NC+NO 077SLD11 180601

I NC+NO 077SLI11 180604

H NC+NO 077SLH11 180602

With I NC+NO 077SLI11DC 180605


spring return
H NC+NO 077SLH11SC 180603

3 positions
B NC+NO 077SLB11 180607
Fixed E NC+NO 077SLE11 180611
U 2NC+2NO 077SLU22 180619
Z 2NC+2NO 077SLZ22 180623

With B NC+NO 077SLB11SC 180608


spring return E NC+NO 077SLE11SC 180612
U 2NC+2NO 077SLU22SC 180620
Z 2NC+2NO 077SLZ22SC 180624

B NC+NO 077SLB11DC 180609


E
U
NC+NO
2NC+2NO
077SLE11DC
077SLU22DC
180613
180621 A
Z 2NC+2NO 077SLZ22DC 180625

B NC+NO 077SLB11RC 180610


E
U
NC+NO
2NC+2NO
077SLE11RC
077SLU22RC
180614
180622 B
Z 2NC+2NO 077SLZ22RC 180626

4 positions
X 2NC+2NO 077SLX22 180606
C
Fixed

E
(1) Electrical diagrams, see E.69 The catalogue numbers in bold are available from stock.

E.53

32764_E48_E81_E.indd 53 12-07-2005 15:17:19


Series 077
Selector switches with key (1)
2 positions Function (2) Contacts Key removal Cat. no. Ref. no.
D NC+NO I 077SCD1101 180630
Fixed NC+NO II 077SCD1105 180631
NC+NO I-II 077SCD1109 180632

I NC+NO 0 077SCI1103 180637


NC+NO I 180638
Control and signalling units

077SCI1105
NC+NO 0-I 077SCI1114 180639

H NC+NO 0 077SCH1103 180634

With I NC+NO 0 077SCI11DC03 180640


spring return
H NC+NO 0 077SCH11SC03 180636

3 positions
B NC+NO I 077SCB1101 180840
Fixed NC+NO 0 077SCB1103 180841
NC+NO II 077SCB1105 180842
NC+NO I-0 077SCB1107 180846
NC+NO I-II 077SCB1109 180844
NC+NO 0-II 077SCB1114 180845
NC+NO I-0-II 077SCB1120 180843

U 2NC+2NO I 077SCU2201 180882


2NC+2NO 0 077SCU2203 180883

A 2NC+2NO
2NC+2NO
II
I-0
077SCU2205
077SCU2207
180884
180885
2NC+2NO I-II 077SCU2209 180886
2NC+2NO I-0-II 077SCU2220 180888

B Z 2NC+2NO
2NC+2NO
I
I-0
077SCZ2201
077SCZ2207
180896
180899
2NC+2NO I-II 077SCZ2209 180900
2NC+2NO I-0-II 077SCZ2220 180902

C
Keys
D Standard version 01 02 03 04 05 10 16 19 53

FIAT version number F033 F034 F037 F038 F040


Colour yellow black red bleu orange

E The catalogue numbers in bold are available from stock.

(1) Supplied with two standard keys 3095. To order a device with different keys add the number for the type of the
key to the catalogue number.
F (2) Electrical diagrams, see E.69

E.54

32764_E48_E81_E.indd 54 12-07-2005 15:17:19


Series 077
Selector switches with key (1)

Control and signalling units Ø 30 mm


3 positions Function (2) Contacts Key removal Cat. no. Ref. no.
B NC+NO 0 077SCB11SC03 180848
With
spring return U 2NC+2NO 0 077SCU22SC03 180890
2NC+2NO II 077SCU22SC05 180889
2NC+2NO 0-II 077SCU22SC14 180891

Z 2NC+2NO 0 077SCZ22SC03 180904


2NC+2NO II 077SCZ22SC05 180903
2NC+2NO 0-II 077SCZ22SC14 180905

B NC+NO I-0 077SCB11DC07 180852

U 2NC+2NO I 077SCU22DC01 180892


2NC+2NO 0 077SCU22DC03 180893
2NC+2NO I-0 077SCU22DC07 180894

Z 2NC+2NO I 077SCZ22DC01 180906


2NC+2NO 0 077SCZ22DC03 180907
2NC+2NO I-0 077SCZ22DC07 180908

B NC+NO 0 077SCB11RC03 180853


U 2NC+2NO 0 077SCU22RC03 180895
Z 2NC+2NO 0 077SCZ22RC03 180909

4 positions
X 2NC+2NO I 077SCX2201 180650
Fixed 2NC+2NO II 077SCX2202 180651
2NC+2NO III 077SCX2204 180652
2NC+2NO IV 077SCX2205 180653
2NC+2NO I-II-III-IV 077SCX2228 180666
A

B
Keys
Standard version 01 02 03 04 05 10 16 19 53

FIAT version number F033 F034 F037 F038 F040 C


Colour yellow black red bleu orange

The catalogue numbers in bold are available from stock. D


(1) Supplied with two standard keys 3095. To order a device with different keys add the number for the type of the
key to the catalogue number.
(2) Electrical diagrams, see E.69
E

E.55

32764_E48_E81_E.indd 55 12-07-2005 15:17:20


Series 077
Selector push-buttons
2 positions Function (1) Contacts Cat. no. Ref. no.
see bottom
Fixed 201 2NC+2NO 077PS!201
202 2NC+2NO 077PS!202

203 NC+NO 077PS!203


204 NC+NO 077PS!204
Control and signalling units

205 2NC+2NO 077PS!205


206 2NC+2NO 077PS!206
213 2NC+2NO 077PS!213
221 2NC+2NO 077PS!221
222 2NC+2NO 077PS!222
231 2NC+2NO 077PS!231
235 2NC+2NO 077PS!235
236 2NC+2NO 077PS!236

3 positions
301 2NC+2NO 077PS!301
Fixed 302 2NC+2NO 077PS!302

311 NC+NO 077PS!311

323 2NC+2NO 077PS!323


325 2NC+2NO 077PS!325

(1) Electrical diagrams, see E.70 The catalogue numbers in bold are available from stock.

Colours black red


A ● N R

For reference numbers,


see chapter X, pg. X.12

E.56

32764_E48_E81_E.indd 56 12-07-2005 15:17:21


Series 077
Joysticks

Control and signalling units Ø 30 mm


2 positions + central zero position Function (1) Contacts Cat. no. Ref. no. Cat. no. Ref. no.
Without interlock With interlock
fixed position N 2NC+2NO 077MTS2422 180910 077MTS2422B 181000
4 0 2
R 2NC+2NO 077MTS2422R 180912 077MTS2422RB 181002

transient position N 2NC+2NO 077MT24S22 180911 077MT24S22B 181001


R 2NC+2NO 077MT24S22R 180913 077MT24S22RB 181003

4 positions + central zero position


fixed positions N 2NC+2NO 077MTS123422 180914 077MTS123422B 181004
1 transient positions 2NC+2NO 077MT1234S22 180915 077MT1234S22B 181005
1 fixed-2,3,4 transient 2NC+2NO 077MT234S122 180917 077MT234S122B 181007
4 0 2 1,2,3 transient-4 fixed 2NC+2NO 077MT123S422 180916 077MT123S422B 181006
3

2+2 positions + central zero position (2)


fixed positions X 4NC+4NO 077M2S2SX44 180918 077M2S2SX44B 181008
transient positions 4NC+4NO 077M2T2TX44 180919 077M2T2TX44B 181009
4,8 fixed -3,7 transient 4NC+4NO 077M2T2SX44 180920 077M2T2SX44B 181010
4,8 transient -3,7 fixed 4NC+4NO 077M2S2TX44 180921 077M2S2TX44B 181011

8 7 0 3 4 fixed positions Y 4NC+4NO 077M2S2SY44 180922 077M2S2SY44B 181012


transient positions 4NC+4NO 077M2T2TY44 180923 077M2T2TY44B 181013
4,8 fixed -3,7 transient 4NC+4NO 077M2T2SY44 180924 077M2T2SY44B 181014 A
4,8 transient -3,7 fixed 4NC+4NO 077M2S2TY44 180925 077M2S2TY44B 181015

4+4 positions + central zero position (2) B


fixed positions X 8NC+8NO 077M4S4SX88 180926 077M4S4SX88B 181016
transient positions 8NC+8NO 077M4T4TX88 180927 077M4T4TX88B 181017
2,4,6,8 fixed - 1,3,5,7 transient 8NC+8NO 077M4T4SX88 180928 077M4T4SX88B 181018
2
1
2,4,6,8 transient -1,3,5,7 fixed 8NC+8NO 077M4S4TX88 180929 077M4S4TX88B 181019
C
8 7 0 3 4 fixed positions Y 8NC+8NO 077M4S4SY88 180930 077M4S4SY88B 181020
transient positions 8NC+8NO 077M4T4TY88 180931 077M4T4TY88B 181021
5 2,4,6,8 fixed - 1,3,5,7 transient 8NC+8NO 077M4T4SY88 180932 077M4T4SY88B 181022
6 2,4,6,8 transient - 1,3,5,7 fixed 8NC+8NO 077M4S4TY88 180933 077M4S4TY88B 181023
D
The catalogue numbers in bold are available from stock.
E
(1) Electrical diagrams, see E.71
(2) Not approved by RINA and Lloyd’s Register.

E.57

32764_E48_E81_E.indd 57 12-07-2005 15:17:21


Series 077
Illuminated push-buttons
Momentary Description Contacts Cat. no. Ref. no.
Full voltage ; / NC+NO 077PLM11D0 181040
BA9s max 380V - 2 W not included NO+NO 077PLM20D0 181041
NC+NC 077PLM02D0 181042
NO 077PLM10D0 181043
Control and signalling units

With resistor 110-120V ; / NO 077PLM10RJ 181045


BA9s60V-1.2W included

With resistor 220-240V ; / NO 077PLM10RN 181047


BA9s130V-2W included

With transformer 50/60Hz NC+NO 077PLM11T©


BA9s6V-1.5W included

To complete by:
Lenses

Standard 077GPL! see bottom

Mushroom head Ø 35 mm 077GEL! see bottom


(to use with the fixing ring 077GG03)

Locking rings

Without guard 077GG03 180980

With metal guard 077GGM 180981


B

C With transparent guard 077GGT 180982

E
The catalogue numbers in bold are available from stock.

Suffix 110-120V 220-250V 380V


F © J N U

Colours red green yellow orange blue white clear


G Standard lenses R V G A BL B I
Mushroom heads R V G A BL B I

For reference numbers,


see chapter X, pg. X.12

E.58
Series 077
Illuminated selector switches

Control and signalling units Ø 30 mm


2 positions Function (1) Contacts Cat. no. Ref. no.
Full voltage ; / D NC+NO 077ISD11D0 181060
Fixed BA9s max. 380V-2W NO 077ISD10D0 181063
not included NC 077ISD01D0 181064

With transformer 50/60Hz D NC+NO 077ISD11T©


BA9s6V-1.5W included

To complete by:
Lenses

Knob 077MIS! see bottom

(1) Electrical diagrams, see E.69 The catalogue numbers in bold are available from stock.

Suffix 110-120V 220-250V 380V


© J N U

Colours red green yelloworange blue white


● R V G A BL B

For reference numbers,


see chapter X, pg. X.12

E.59
Series 077
Illuminated selector switches
3 positions Function (1) Contacts Cat. no. Ref. no.
Full voltage ; / B NC+NO 077ISB11D0 181170
Fixed BA9s max. 380V-2W Z NC+NO 077ISZ11D0 181172
not included

With transformer 50/60Hz B NC+NO 077ISB11T©


BA9s6V-1.5W included
Control and signalling units

With Full voltage ; / B NC+NO 077ISB11D0RC 181174


spring return BA9s max. 380V-2W Z NC+NO 077ISZ11D0RC 181176
not included

With transformer 50/60Hz B NC+NO 077ISB11T©RC see bottom


BA9s6v-1.5w included

To complete by:
Lenses

Knob 077MIS! see bottom

(1) Electrical diagrams, see E.69 The catalogue numbers in bold are available from stock.

Suffix 110-120V 220-250V 380V


© J N U

A Colours red green yellow orange blue white


● R V G A BL B

For reference numbers,


see chapter X, pg. X.12

E.60

32764_E48_E81_E.indd 60 12-07-2005 15:17:23


Series 077
Pilot lights

Control and signalling units Ø 30 mm


Description Cat. no. Ref. no.
Full voltage ; / 077LDNV0 181300
BA9s max. 380V-2W not included

With resistor ; / 077LRNVJ 181301


110-120V, BA9s60V-1.2W included 077LRNVN 181302
220-240V, BA9s130V-2W included

With resistor ; / 077LREVJ 181303


110-120V, BA9s48V-2W included 077LREVL 181304
125-127V, BA9s48V-2W included

With transformer 50/60Hz 077LTNV©


BA9s6v-1.5w included

Multifunction (1) full voltage 24V ; / 077LDMVD 181305


BA9s24V-2W included

Multifunction (1) with transformer 50/60 Hz 077LTMV©


BA9s6V-0.6W included

To complete by:
Lenses

plastic version 077GL! see bottom

077GL!V see bottom


glass version
A

The catalogue numbers in bold are available from stock.


B
Suffix 110-120V 220-250V 380V 415-440V 480-500V
© J N U W Y
C
Colours red green yellow orange blue white clear
● R V G A BL B I
D
(1) Do not connect for flashing light
X1 X2
Y1 Y2 Link to external contact in order to have steady or flashing light:
Steady light = C closed
E
Flashing light = C open

For reference numbers,


see chapter X, pg. X.12

E.61

32764_E48_E81_E.indd 61 12-07-2005 15:17:23


Series 077
Pilot lights
Description Cat. no. Ref. no.
Full voltage ; /
For bulb E14 base max 660V(1)-6W not included 077DLE14 181260

For bulb BA15d base max 660V(1)-6W not included 077DLB15 181290
Control and signalling units

For bulb E5.5 base max 30V-1.2W not included


- 2 signals 077L2 (2) 181350
- 4 signals 077L4 (2) 181351

To complete by:
Lenses

For pilot lights 077DLE14, 077DLB15


- plastic version 099GW1! see bottom
- glass version 077GDLV! see bottom

For pilot lights 077L2


- plastic version, white colour 077GL2B 181377
A For pilot lights 077L4
- plastic version, white colour 077GL4B 181387

Coloured filter cap


B - for pilot lights 077L2, 077L4 099CF!

D (1) For Canadian market max. 125 V The catalogue numbers in bold are available from stock.
according to CSA standards.
(2) Not approved by RINA and
Lloyd’s Register. Colours ● red green yellow orange blue white clear
E Lenses R V G A BL B I
Filter caps R V G – BL – –

For reference numbers,


see chapter X, pg. X.12

E.62
Series 077
Accessories

Control and signalling units Ø 30 mm


Description Cat. no. Ref. no.
Push-on/ For momentary standard push-buttons 077DPP 181550
push-off device Converts momentary push-button to push-on/push-off.
This device can only be used with 077-01 (NC)
and/or 077-10A (NO early make) contact blocks.

Push-pull to For momentary mushroom 077DAE 181554


release device push-buttons
Converts momentary mushroom push-button to
push to latch/pull to release.

Mechanical For momentary standard or dia 35 mm. 077DAMP 181557


latch mushroom push-buttons
Makes mechanical latch between
two push buttons.

Mechanical For momentary standard push-buttons 077DIM 181553


interlock Prevents simultaneus operation of two push buttons.

Resetting For momentary standard push-buttons 077DRR 181555


device Converts momentary push-button to resetting push-button.

Fixing kit operator complete with guard-ring, 077GGBCR 181556


transparent cap, function disk, compensation rings
and washer.

R (reset) (stop/reset)
A
Knob for selector switches 077M! see bottom
Handles Lever for selector push-buttons 077LPS 181604 B

Protection Guard-ring for mushroom head push-button dia 35 mm. 077GE35 181620
C

D
Plug For unused mounting hole. 077TPF 181601

E
Potentiometer Suitable for potentiometers with shaft 50 mm long 077OPZ 181570
operator and 6 mm diameter. Potentiometer not included.
F

Rubber For standard push-buttons


protective – coloured
– clear
077CP!
077CPT
see bottom
181588
G
caps
For illuminated standard push-buttons
– clear 077CPLT 181600

For knob selector switches


H
– black colour with clear knob 077CST 181603

For lever selector switch


– black colour 077CSLN 181605 I
For key selector switches
– black colour 077CSCN 181606

The catalogue numbers in bold are available from stock.

Colours ● black red green yellow blue For reference numbers,


see chapter X, pg. X.12
Knobs N R V G BL
Protective caps N R V G –

E.63
Series 077
Accessories (continued)
Description Cat. no. Ref. no.
Fixing rings Without guard 077GS01 181610
For standard, latched and timed push-buttons (077867-01)

Without guard 077GS02 181611


For illuminated selector switch and standard pilot lights (077867-02)
Control and signalling units

Without guard 077GS03 181612


For pilot lights DLE14, DLB15, L2, L4 types (077867-03)

With guard 077GG01 181613


For standard, mushroom, key and timed push-buttons (077867-04)

With guard 077GG02 181614


For standard selector switch, joystick and potentiometers operator (077867-05)

Without guard 077GG03 180980


For illuminated push-buttons (077867-06)

With metal guard 077GGM 180981


For illuminated push-buttons (077867-07)

With transparent guard 077GGT 180982


For illuminated push-buttons (077867-08)

With extended guard 077GE01 181618


For standard and timed push-buttons (077867-09)

With extended guard 077GE02 181619


For selector push-buttons (077867-10)

Locking ring wrench 099CH1 181621


A

B Spare keys Standard version Code

3095 077C3095 173095


9901 077C9901 179901
C 9902
9903
077C9902
077C9903
179902
179903
9904 077C9904 179904
9905 077C9905 179905
9910 077C9910 179910
D 9916
9919
077C9916
077C9919
179916
179919
3353 077C3353 179353

FIAT-version Colour
E yellow 73033 077CF73033 173333
black 73034 077CF73034 173334
red 73037 077CF73037 173337
blue 73038 077CF73038 173338
F orange 73040 077CF73040 181622

The catalogue numbers in bold are available from stock.


G

E.64
Series 077
Accessories (continued)

Control and signalling units Ø 30 mm


Description Cat. no. Ref. no.
Bulbs BA9s Filament type Vn Wn

6 0.6 BA9S606 187850


6 1.5 BA9S615 187851
12 2 BA9S122 187852
24 2 BA9S242 187853
30 2.1 BA9S30 187854
48 2 BA9S48 187855
60 1.2 BA9S6012 187856
130 2 BA9S130 187857

Neon type 110 0.11 BA9SN110 187860


220 0.33 BA9SN220 187861

Mono LED Vn AC/DC ± 10%


6 BA9S6L! see bottom
12 BA9S12L! see bottom
24 BA9S24L! see bottom
48 BA9S48L! see bottom
110 BA9S110L! see bottom
(DC) 230 BA9S230L! see bottom

Bulbs BA15d Filament type Ve Vn Pn

24 24 3C 077BA15D24 181630
30 24/30 4W 077BA15D30 181631
48 60 3C 077BA15D60 181632
60 60 3C 077BA15D60 181633
110 110/130 3C 077BA15D130 181634
130 140 3W 077BA15D140 181635
160 220/230 3C 077BA15D220 181636
220 230 6W 077BA15D230 181637 A
Bulbs E14 Filament type Ve Vn Pn

24 30 5 099E1430 181730
30
48
40
60
5
5
099E1440
099E1460
181731
181732
B
110 160 7.5 099E14160 181733
130 220 10.5 099E14220 181734
160 250/260 12 099E14250 181735
220 220/260 6 099E14260R 181736 C
Bulbs E5.5 Filament type Vn Pn

6 1.2 099E5,56 181640


12
24
1.2
1.2
099E5,512
099E5,524
181641
181642
D

The catalogue numbers in bold are available from stock. E


Colours ● red green yellow blue white
Mono LED R V G BL B
F

For reference numbers,


see chapter X, pg. X.12

E.65
Series 077
Nameplates
Description Cat. no. Ref. no.
For push-button Without text (black background) 077TNA 181650
and pilot lights
With text in English (black background) STOP 077TNA40 181840
START 077TNA41 181841
POWER ON 077TNA42 181842
Control and signalling units

CANCEL 077TNA43 181843


DOWN 077TNA44 181844
STOP UP 077TNA45 181845
CLOSE 077TNA46 181846
OPEN 077TNA47 181847
SLOW 077TNA48 181848
FAST 077TNA49 181849
INCH 077TNA50 181850
RUN 077TNA52 181851
ON 077TNA53 181852
OFF 077TNA54 181853
FORWARD 077TNA55 181854
REVERSE 077TNA56 181855
RAISE 077TNA59 181857
LOWER 077TNA60 181858
PUMP START 077TNA61 181856

For 2 position selector Without text (black background) 077TNA2 181660


switch and selector
push-button With text (black background) ON - OFF 077TNA230 181930
MAN - AUTO 077TNA231 181931
UP - DOWN 077TNA232 181932
TEST - RUN 077TNA233 181933
JOG - RUN 077TNA234 181934

For 2 position selector Without text (black background) 077TNA3 181670


A switch and selector
push-button With text (black background)
MANUAL CYCLE-O-AUTOMATIC 077TNA301 181951
AUTO - OFF - HAND 077TNA310 181960
FORWARD - OFF - RUN 077TNA311 181961
B OPEN - OFF - CLOSE
UP - OFF - DOWN
077TNA312
077TNA313
181962
181963

For 4 position Without text (black background) 077TNA4 181680


selector switches
C

D For joysticks Without text (black background) 077TNC 181700


and selector switches

E
For potentiometer Without text (black background) 077TNCS 181710
operators
F

Dia 62 mm for
G emergency
Without text (yellow background) 077TGR 181720

push-buttons

H
The catalogue numbers in bold are available from stock.
I

E.66
Series 077
Contact blocks

Control and signalling units Ø 30 mm


2 positions Contacts Cat. no. Ref. no.
For all the applications
Illuminated push-buttons and illuminated
selector
switches excluded
Standard NC+NO 077-11 180001

NC 077-01 180003

NO 077-10 180002

NC late opening 077-01R 180008

NO early 077-10A 180007


closing

Golded NC+NO 077-11D 180004

NC 077-01D 180006

NO 077-10D 180005
A

Accessories for contact blocks 077-...


IP2X protection for use with NO 077PTB10 181608
B
for use with NC 077PTB01 181609
for use with 077PTB11 181615
NO+NC

For 2 + 2 and 4 + 4 positions joysticks


C
Snap action 099SPDTDB(1) 180009

D
For illuminated push-buttons and
illuminated selector switches

NC+NO P9B11VN 187000


E

NC P9B01VN 187001 F

NO P9B10VN 187002
G

(1) Not approved by RINA and Lloyd’s Register. H

E.67

32764_E48_E81_E.indd 67 12-07-2005 15:17:43


Series 077
Enclosures for push-button stations in aluminium alloy (Grey RAL 7012)
Cat. no. Ref. no.
Cover with holes
with conduit entry No. of holes Type
1 1 077SP1 180521
1 1M 077SP1M 180522
2 2 077SP2 180523
Control and signalling units

2 2M 077SP2M 180524
3 3 077SP3 180525
4 4V 077SP4V 180526
4 4 077SP4 180527
6 6 077SP6 180528
9 9 077SP9 180529
12 12 077SP12 180530
16 16 077SP16 180531
20 20 077SP20 180532
25 25 077SP25 180533
30 30 077SP30 180534
36 36 077SP36 180535

Cover with holes No. of holes Type


without conduit entry 1 1 077SP1SFE 180536
1 1M 077SP1MSFE 180537
2 2 077SP2SFE 180538
2 2M 077SP2MSFE 180539
3 3 077SP3SFE 180540
4 4V 077SP4VSFE 180541
4 4 077SP4SFE 180542
6 6 077SP6SFE 180543
9 9 077SP9SFE 180544
12 12 077SP12SFE 180545
16 16 077SP16SFE 180546
A 20
25
20
25
077SP20SFE
077SP25SFE
180547
180548
30 30 077SP30SFE 180549
36 36 077SP36SFE 180550

B Cover without holes Type


with conduit entry 1 080SP1SFC 170835
1M 080SP1MSFC 170838
2 080SP2SFC 170841
C 2M
3
080SP2MSFC
080SP3SFC
170844
170847
4V 077SP4VSFC 180551
4 080SP8SFC 170853
6 080SP12SFC 170856
D 9
12
080SP12SFC
080SP18SFC
170856
170859
16 080SP18SFC 170859
20 080SP35SFC 170863
25 080SP35SFC 170863
E 30
36
077SP36SFC
077SP36SFC
180552
180552

Cover without holes Type


F without conduit entry 1
1M
080SP1SF
080SP1MSF
170837
170840
2 080SP2SF 170843
2M 080SP2MSF 170846
3 080SP3SF 170849
G 4V
4
077SP4VSF
080SP8SF
180553
170855
6 080SP12SF 170858
9 080SP12SF 170858
12 080SP18SF 170861
H 16
20
080SP18SF
080SP35SF
170861
170865
25 080SP35SF 170865
30 077SP36SF 180554
36 077SP36SF 180554
I
Accessories
Kit of two hinges for types from
12 to 36 holes. 080KCSP 170883

X
The catalogue numbers in bold are available from stock.

E.68
Series 077
Diagrams

Control and signalling units Ø 30 mm


Selector switches Illuminated selector switches
Func. Contacts Diagram Full voltage Func. Contacts Diagram
type
I II
3 4 I II
120
D 077 11... 120 D 077 10... 13 14
1 2
077 01... 21 22

077 10... I II
0 I D 13 14

3 4
077 10... 23 24
60 I 077 11... 1 2
077 01... I II
D 11 12
077 01... 21 22

I 0 I II
3 4 D 077 10... 13 14
60 H 077 11... 1 2
D 077 01... I II
11 12

I 0 II
I 0 II
3 4 60 60 B 077 10... 13 14
60 60 B 077 11... 1 2 077 01... 21 22

I 0 II
60 60 Z 077 10... 13 14

I 0 II 077 01... 21 22
3 4
60 60 E 077 11... 1 2 Transformer type
13 14
I II A
120 D 077 11...
11 12
I 0 II
077 11... 3 4 I 0 II
60 60
U 1 2
60 60 B 077 11... 13
11
14
12
B
3 4
077 11...
1 2

I 0 II
C
077 11... 3 4
60 60
Z 1 2

077 11...
3
1
4
2 D

40
077 11... 3 4
I II III IV
E
40 40 X 1 2

077 11... 3 4
1 2
F

■ = closed contact

E.69
Series 077
Diagrams
Selector push-buttons

Positions Function Contacts Normal Depressed Positions Function Contacts Normal Depressed
Control and signalling units

I II I II I II I II
3 4 3 4
120 201 077 11... 120 231 077 11...
1 2 1 2

3 4 3 4
077 11... 1 2 077 11... 1 2

3 4 I II I II I II I II
120 202 077 11... 120 235 077 11... 3 4
1 2
1 2
3 4
077 11... 3 4
1 2 077 11... 1 2

I II I II
120 203 077 11... 3 4
I II I II
1 2 120 236 077 11... 3 4
1 2
3 4
077 11... 1 2
I II I II
120 204 077 11... 3 4
1 2

A I II III I II III
I II I II 301 077 11... 3 4
3 4 60 60
120 205 077 11... 1 2
1 2 3 4
077 11...
B 077 11...
3
1
4
2
1 2

3 4
I II III I II III
I II I II 302 077 11...
C 120 206 077 11... 3
1
4
2
60 60 1 2

3 4

077 11...
3 4 077 11... 1 2
1 2

D
I II I II I II III I II III
3 4
120 213 077 11... 3 4
60 60 311 077 11...
1 2 1 2

E 077 11... 3 4
1 2
I II III I II III
3 4
323 077 11...
60 60 1 2

F 120 221 077 11... 3 4


I II I II
077 11...
3 4

1 2 1 2

3 4
077 11... 1 2

G 325 077 11... 3 4


I II III I II III
60 60
1 2
I II I II
120 222 077 11... 3 4
077 11... 3 4
1 2 1 2
H 077 11...
3 4
1 2

I ■ = closed contact = can not be depressed.

E.70
Series 077

Control and signalling units Ø 30 mm


Joysticks

Positions Function Contacts Diagram Positions Function Contacts Diagram

4 3 0 7 8 2 0 4
3 4
X 077 11... 3 4 N 077 11...
1 2
1 2 4 0 2
3 4
3 4
077 11... 2
077 11... 1 2
1
3 4
077 11... 1 2

3 4
077 11... 1 2
2 0 4
R 077 11... 3 4
1 2
8 7 0 3 4 3 4
077 11... 1 2
4 3 0 7 8
3 4
Y 077 11... 1 2
3 4
077 11... 1 2
3 4
1 1 2 0 3 4
077 11... 1 2
N 077 11... 3 4
3 4
4 0 2
1 2
077 11... 1 2 3
3 4
077 11... 1 2
A
2 1 4 3 0 5 6 7 8
X 077 11... 3 4

077 11...
1
3
2
4
B
1 2
3 4
077 11...
1 2

077 11... 3 4 C
1 2
3 4
077 11... 1 2

077 11...
3
1
4
2
D
3 4
077 11... 1 2

2
1
077 11...
3
1
4
2
E
8 7 0 3 4
5 2 1 4 3 0 5 6 7 8
6 Y 077 11... 3
1
4
2
F
3 4
077 11...
1 2

077 11... 3
1
4
2
G
3 4
077 11... 1 2
3 4
077 11... 1 2 H
3 4
077 11... 1 2
3 4
077 11... 1
3
2
4
I
077 11... 1 2

■ = closed contact
X

E.71
Series 077
Dimensional drawings
Push-buttons
077P_ _ 077P11T_ _ _ 077E_ _
Control and signalling units

077RE_ _ 077PC11_ _

Selector switches
077S_ _ _ _ 077SL_ _ _ _ 077SC_ _ _ _

Selector push-button
B
077PS_ _ _ _

D
Joysticks
E 077MT_ _ _ _ 077M2_ _ _ _ 077M4_ _ _ _

G Illuminated push-buttons
077PLM_ _D_ 077PLM_ _T_
077PLM_ _R_
H

Illuminated selector switches


X
077IS_ _ _D_ 077IS_ _ _T_
077IS_ _ _R_

E.72

32764_E48_E81_E.indd 72 12-07-2005 15:17:50


Series 077

Control and signalling units Ø 30 mm


Pilot lights
077DLE14

077LDN_ _ / LRN _ _ / LRE _ _

077LTN_ _ / LDM _ _ / LTM

077DLB15 077L2 077L4

Kits
077DPP 077DAMP 077DRR
077DAE 077DIM

077DEL 077OPZ
B

Nameplates D

077TNA 077TNA2 077TNA3 077TNA4 F

H
077TNC 077TNCS 077TGR

Contact blocks I
077-11 077-10 099SPDT-DB
077-01
X

E.73

32764_E48_E81_E.indd 73 12-07-2005 15:17:51


Series 077
Dimensional drawings
Aluminium enclosures

C
Control and signalling units

B D
1 2
Ømax
H
A 50
4 3

30 L

F
E

Number of holes Ø 30 Dimensions Fixing templates


A B C D E HxLxØmax position
Type Vertic. Horizont. F
A 1 - -
(mm)
87
(mm)
87
(mm)
75
(mm)
72
(mm)
21.5 PG 21
(mm)
74x55x4
of the holes
1-3
1M - - 87 87 100 97 21.5 PG 21 68x55x4 1-3
2 2 - 145 87 75 72 21.5 PG 21 132x55x4 1-3
B 2M
3
2
3
-
-
145
195
87
87
100
100
97
97
21.5
21.5
PG 21
PG 21
126x55x4
176x55x4
1-3
1-3
4V 4 - 257 92 86.5 83.5 23 PG 21 224x76x6 1-3
4 2 2 152 152 101.5 98.5 27 PG 29 136x119x6 1-3
2 3 205 230 101.5 98.5 27 PG 29 172x214x6 1-2-3-4
C 6
9 3 3 205 230 101.5 98.5 27 PG 29 172x214x6 1-2-3-4
12 3 4 257 300 101.5 98.5 35 PG 36 221x282x6 1-2-3-4
16 4 4 257 300 101.5 98.5 35 PG 36 221x282x6 1-2-3-4
20 5 4 350 350 123.5 106.5 41 PG 36 180x180x10 1-2-3-4
D 25 5 5 350 350 123.5 106.5 41 PG 36 180x180x10 1-2-3-4
30 6 5 410 410 144.5 127.5 53 PG 48 180x180x10 1-2-3-4
36 6 6 410 410 144.5 127.5 53 PG 48 180x180x10 1-2-3-4

E.74
Series 077
Notes

Control and signalling units Ø 30 mm


. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

E.75
Series NLT
Light towers

• Outstanding modular concept.


One terminal unit can be combined with up to seven modular
signal units.
Control and signalling units

• Steady light units, flashing light units, strobe light units, LED light units.
• The buzzer elements emit a clearly audible dual-tone signal for maximum
safety.
• A bayonet mounting, through a simple manual operation, allows a quick and
simultaneous method of joining the signal units together and the electrical
connection of them.
• Compact dimension Ø70mm.
• IP65 for use in extreme conditions.
• Captive screw cable connectors, located with terminal unit are easy to reach
and guarantee a quick and neat electrical connection.
• The special design makes maintenance quick, easy and carried out in
complete safety and without tools.
• The high quality of materials used to manufacture the lenses ensures the
light output is at the highest luminous intensity, combined with a sturdy
construction and a good resistance to aging.

A Marking

C Meaning of optical signals


Colour Meaning Operating state

D Red Extreme danger


Hazardous conditions
Immediate action necessary

Yellow / Amber Beware Abnormal state


E Warning conditions imminent Monitor or action as necessary

Green Normal conditions No actions required


F
Blue Conditions requiring Discontinuity
G defined action Intervention mandatory

White / Clear No particular meaning Other state


H Can be used as required

I
Meaning of audible signals (EN 981, IEC 73)
X Signal tone Meaning Operating state

Intermittent Danger Immediate action necessary


Modulated tone
Linear tone Safety No actions required

E.76
Series NLT
Light units Audio units

NLT1... Steady light unit NLT73BD Pulsating tone


- With socket BA15D for filament bulbs - Protection degree IP54
(7W max.) and LEDs - Tone: pulsating
- Supply voltage: 240V AC/DC - Audio frequency: 2900Hz
- Current consumption (with 5W lamps): - Pulsating tone frequency:
0,5Hz according to EN 457
24V 115V 240V - Sound level at 1 m.: 90 dB (A)
210mA 43mA 22mA - Supply voltage: 24V AC/DC
- Current consumption: 20mA

NLT75AJ - NLT75AN Pulsating or constant tone


Flashing light unit

Light towers
NLT2...
- Protection degree IP54
- With socket BA15D for filament bulbs - Tone: pulsating or constant
(7W max.) and LEDs - Audio frequency:
- Supply voltage: 2600Hz according to EN 457
24V AC/DC, 115V AC, 240V AC - Pulsating tone frequency:
- Current consumption (with 5W lamps): 1Hz according to EN 457
24V DC 24V AC 115V AC 240V AC - Sound level at 1 m.:
130mA 145mA 25mA 15mA pulsating tone: 95 dB (A)
constant tone: 93 dB (A)
Pulsating or constant tone, - Supply voltage:
115VAC (NLT75AJ) / 240VAC (NLT75AN)
adjustable by removing or
inserting bridge JP1 in the - Current consumption: A
NLT3... Strobe light unit printed circuit. 115VAC 240VAC
40mA 30mA
- Lamp type: 4 Joule xenon lamp
- Supply voltage: B
24V AC/DC, 115V AC, 240V AC NLT75BD Modulated tone
- Current consumption:
- Protection degree IP54
24V DC 24V AC 115V AC 240V AC
75mA 135mA 20mA 15mA
- Audio frequency:
2500 - 2800Hz according to EN 457
C
- Flash frequency: 1,4Hz - Sound level at 1 m.: max. 90 dB (A)
(84 flashes per min.) - Supply voltage: 24V AC/DC
according with EN - Current consumption: 40mA
D
16 sounds can be selected
by means of the dip switch
NLT4... Integrated LED light unit
- High-luminosity LEDs
E
- Three light types: steady, blinking and NLT77BD Pulsating tone
rotating (adjustable by removing or moving
the bridge CN1) - Protection degree IP65
- Supply voltage: 24V AC/DC - Audio frequency: F
- Current consumption (for all types of light): 1200 - 2600Hz according to EN 457
- Sound level at 1 m.: max. 84 dB (A)
24V DC 24V AC - Supply voltage: 24V AC/DC
55mA 85mA
- Flash frequency: 1,4Hz
- Current consumption: 40mA G
(84 flashes per min.)
according with EN 60073
- Rotation frequency: 1 rotation per sec.
NLT77AJ - NLT77AN Pulsating or constant tone H
- Protection degree IP65
- Tone: pulsating or constant
- Audio frequency:
2600Hz according to EN 457
I
- Pulsating tone frequency:
1Hz according to EN 457
- Sound level at 1 m.:
pulsating tone: 78 dB (A)
X
constant tone: 75 dB (A)
Pulsating or constant tone, - Supply voltage:
adjustable by removing or 115VAC (NLT77AJ) / 240VAC (NLT77AN)
inserting bridge JP1 in the - Current consumption:
printed circuit. 115VAC 240VAC
40mA 30mA

E.77
Series NLT
Light units
Red Amber Yellow Green Blue Clear

Supply
Control and signalling units

voltage Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no. Pack

Steady light units 12...240V NLT1R 222230 NLT1A 222231 NLT1G 222232 NLT1V 222233 NLT1L 222234 NLT1I 222235 1
(bulb not included)

Flashing light units 24V AC/DC NLT2BDR 222236 NLT2BDA 222237 NLT2BDG 222238 NLT2BDV 222239 NLT2BDL 222240 NLT2BDI 222241 1
(bulb BA15D 115V AC NLT2AJR 222242 NLT2AJA 222243 NLT2AJG 222244 NLT2AJV 222245 NLT2AJL 222246 NLT2AJI 222247 1
filament) 240V AC NLT2ANR 222248 NLT2ANA 222249 NLT2ANG 222250 NLT2ANV 222251 NLT2ANL 222252 NLT2ANI 222253 1
(bulb included)

Flashing light 24V AC/DC NLT2BDLR 222289 NLT2BDLA 222290 NLT2BDLG 222291 NLT2BDLV 222292 NLT2BDLL 222293 NLT2BDLI 222294 1
units (bulb LED) 115V AC NLT2AJLR 222295 NLT2AJLA 222296 NLT2AJLG 222297 NLT2AJLV 222298 NLT2AJLL 222299 NLT2AJLI 242464 1
A (bulb included) 240V AC NLT2ANLR 222301 NLT2ANLA 222302 NLT2ANLG 222303 NLT2ANLV 222304 NLT2ANLL 222305 NLT2ANLI 222306 1

C Strobe light units 24V AC/DC NLT3BDR 222254 NLT3BDA 222255 NLT3BDG 222256 NLT3BDV 222257 NLT3BDL 222258 NLT3BDI 222259 1
(bulb included) 115V AC NLT3AJR 222260 NLT3AJA 222261 NLT3AJG 222262 NLT3AJV 222263 NLT3AJL 222264 NLT3AJI 222265 1
240V AC NLT3ANR 222266 NLT3ANA 222267 NLT3ANG 222268 NLT3ANV 222269 NLT3ANL 222270 NLT3ANI 222271 1

E Multifunction 24V AC/DC NLT4BDR 222272 NLT4BDA 222273 NLT4BDG 222274 NLT4BDV 222275 NLT4BDL 222276 NLT4BDI 222277 1
integrated
LED light units
(steady, blinking,
F rotating light)

E.78
Series NLT
Audio units
Protection degree Supply voltage Cat. no. Ref. no. Pack

Pulsating tone IP54 24V AC/DC NLT73BD 222278 1

IP65 24V AC/DC NLT77BD 222279 1

Pulsating or constant tone IP54 115V AC NLT75AJ 222287 1


Adjustable by removing or inserting bridge JP1 in the printed circuit 240V AC NLT75AN 222288 1

IP65 115V AC NLT77AJ 222280 1

Light towers
240V AC NLT77AN 222281 1

Modulated tone IP54 24V AC/DC NLT75BD 222286 1


16 sounds can be selected by means of dip switch

The audio units can only be mounted as final top unit (top cover included)

Bulbs
Red Amber Yellow Green Blue White
A
Supply
voltage Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no. Pack

LED - BA15D 24V AC/DC BA15D24LR 222330 BA15D24LA 222331 BA15D24LG 222332 BA15D24LV 222333 BA15D24LL 222334 BA15D24LB 222335 1
115V AC BA15D115LR222336BA15D115LA222337BA15D115LG222338BA15D115LV 222339 BA15D115LL 222340BA15D115LB222341 1
B
240V AC BA15D230LR222342BA15D230LA222343BA15D230LG222344BA15D230LV 222345 BA15D230LL 222346BA15D230LB222347 1

Incandescent Supply Clear D


BA15D voltage Cat. no. Ref. no. Pack

12V BA15D125 222348 5


24V BA15D245 222349 5
30V BA15D305 222350 5 E
115V BA15D1155 222351 5
240V BA15D2305 222352 5

F
Terminal
Cat. no. Ref. no. Pack

Terminal unit with top cover NLT9TC 222282 1


G

Base with tube I


Cat. no. Ref. no.Pack

Base + tube height 100mm NLT5BT 222284 1


Base + tube height 100mm, 90° fixing NLT90BT 222307 1
X
Tube height extension 100mm NLT5ET 222285 1

E.79
Series NLT
Technical data
Conformity to standards EEC regulation 89/336 electromagnetic compatibility
EEC regulation 73/23 low voltage, including amendment EEC 93/68
All NLT range are made and tested in full compliance with:
EN 60947-5-14 (VDE 0470, IEC 60947)
CE, cUS UL (on process)
Materials Polycarbonate
Control and signalling units

Visual and audio signal units, terminal unit, top cover, base and extension tubes
Rated insulated voltage 250V max.
Operating temperature -20°C ... +60°C (except version with bulb 12V = 40°C)
Protection degree IP65 (IP54 for audio units types NLT73xx and NLT75xx)
(according to EN 60529) (indicators must be correctly assembled with top cover, gasket or PG conduit fitting)
Colours Amber, Blue, Yellow, Clear, Red and Green
(according to EN 60073)
Lamp type
Steady/flashing units Bayonet type BA15D socket: filament (7W max.) or LED
Strobe units Xenon lamps
Nr. of combined units Up to 7 modular units
Connection Captive screw cable connectors (max. cable size 1.5mm2) inside terminal sleeve
«C» is common to allsignal units.
Connection identification code They are numbered 1/7 from base to top

Mechanical characteristics
Mounting of the units
Average torque 2.4Nm
Unfastening of the units
Average torque 2.3Nm
Vibration resistance
A Mounting
2g min. (10-150Hz) according to IEC 68-2-6
Direct through terminal unit or with base and tube

C Dimensions

D Base mounting Terminal unit Base mounting Drilling and mounting


mounting 90º fixing Dimensions with base Ø70

H
Drilling and fixing dimensions with
terminal unit.
Two separate hole spacings.

E.80
Series NLT
Modular system
Place signal beacon unit onto terminal unit (1) align guide marks and twist clockwise till they are locked (2) + (3)

(1) (2) (3)

Light towers
Follow the same steps to add more signal units (4) + (5) + (6)
The audible element can be mounted as final top unit, as it is complete with a top cover.
A

(4) (5) (6) B

To fix extension tube (base always included), insert it into opening on the underside of the terminal unit and tighten screw on the
G
side (7). To reach the screw cable clamp terminals, remove black disc first, prising with a small screwdriver (8). Connect to terminals
(coloured units are numbered from base to top). To place terminal back into position, align the guiding marks (9) and press inwards.
H
(7) (8) (9)
I

E.81
Series 101
Palm push-buttons

General
Series 101 is a range of a palm push-buttons for intensive services suitable for
Control and signalling units

controlling and monitoring of low voltage AC and DC electric circuits.

Climatic protections
The standard versions are suitable for use in the following climates:
• Temperate climate cat. 23/50 (DIN 50014)
• Wet climate cat. 23/83 (DIN 50015)
• Hot wet climate cat. 40/92 (DIN 50015)
• Variable wet climate cat. FW 24 (DIN 50016)

Standards
A
IEC 947-5-1, CEI EN 60947.5.1,
VDE 0660, BSI and UTE

B
Specifications
Temperature ranges Operation from -25ºC up to +70ºC
C Storage
Degree of protecttion (according to IEC 529)
from -40ºC up to +70ºC
IP 65
Vibration resistance 10g, at a sinusoidal ranging from 1 to 100Hz according to IEC 68-2-6
Mechanical endurance 3 x 106 operations for all the types

D Electrical
Rated insulation voltage according to EN 60947.1 690V
Impulse withstand voltage according to VDE 0110 4kV
Insulation class according to VDE 0110 Group C
Electrical shock protection according to IEC 536 Class I
E Short-circuit prot. according to IEC 269.1 and 269.3 10A gL fuses
Electrical performances of the contact blocks
Rated thermal current (Ith) 10A
Performances according to IEC 947-5-1
F Cat. AC 15 (A600) Voltage Ue (V) 24 48 60 110 220 380 500 600
Current Ie (A) 10 10 10 6 3 2 1.5 1.2

Cat. DC 13 (Q300) Voltage Ue (V) 24 48 60 110 220 300


G Current Ie (A) 2.5 1.4 1 0.55 0.27 0.2

Performances according to CSA AC Heavy Duty (A600); DC Standard Duty (Q300)


Connections at same polarity
H

Order codes ! pg. E.83


Dimensional drawings ! pg. E.90

E.82
Series 101
Surface mounting
1NO + 1NC 2NO + 2NC 4NO + 4NC
Colour Cat. no Ref. no. Cat. no Ref. no. Cat. no Ref. no. Pack

Simple action Black 101PMN1 132000 101PMN11 132010 101PMN22 132020 1


Red 101PMR1 132001 101PMR11 132011 101PMR22 132021 1
Green 101PMV1 132002 101PMV11 132012 101PMV22 132022 1
Yelow 101PMG1 132003 101PMG11 132013 101PMG22 132023 1

Palm push-buttons
With latch Black 101PMN1P© C 101PMN11P© C 101PMN22P© C 1
Red 101PMR1P© C 101PMR11P© C 101PMR22P© C 1
Green 101PMV1P© C 101PMV11P© C 101PMV22P© C 1
Yelow 101PMG1P© C 101PMG11P© C 101PMG22P© C 1

Release push-button: replace © by the code corresponding

Colour Green Red Black


Code © V R N
A
Flush mounting
1NO + 1NC 2NO + 2NC
Colour Cat. no Ref. no. Cat. no Ref. no. Pack B
Simple action Black 101FPMN1 132150 101FPMN2 132160 1
Red 101FPMR1 132151 101FPMR2 132161 1
Green 101FPMV1 132152 101FPMV2 132162 1 C
Yelow 101FPMG1 132153 101FPMG2 132163 1

E
Accessories
1NO + 1NC 2NO + 2NC
Cat. no Ref. no. Cat. no Ref. no. Pack F
Microswitch 090MI1 130310 090MI2 130311 1

H
Blank nameplate with 101 TNC 132099 101 TNC 132099 1
cover I

E.83
Series IP
Foot switches
General
Foot switches , for intensive services suitable for controlling and monitoring
of low voltage AC and DC electrical circuits.
Control and signalling units

Climatic protections
The standard versions are suitable for use in the following climates:
• Temperate climate cat. 23/50 (DIN 50014)
• Wet climate cat. 23/83 (DIN 50015)
• Hot wet climate cat. 40/92 (DIN 50015)
• Variable wet climate cat. FW 24 (DIN 50016)

Standards
A
IEC 947-5-1, CEI EN 60947.5.1
VDE 0660

B Approvals
CSA, UL
C
Specifications
Temperature ranges Operation from -30ºC up to +80ºC
Storage from -30ºC up to +80ºC
D Degree of protection (according to IEC 529) IP 65
Vibration resistance 20g (10 up to 55Hz)
Mechanical endurance 2 x 107 for all the types
Electrical
E Rated insulation voltage according to EN 60947.1 500V
Insulation class according to VDE 0110 Group C
Electric shock protection according to IEC 536 Class I
Short-circuit prot. according to IEC 269.1 and 269.3 10A gL fuses
F Electrical performances of the contact blocks
Rated thernal current (Ith) 10A
Performances according to EN 60947.5.1
Slow motion contacts Voltage Ue (V) 24 48 110 220 380
G Category AC 15 Current Ie (A) 6 6 6 6 4

Snap action contacts Voltage Ue (V) 24 48 110 220 380


Category AC 15 Current Ie (A) 6 6 6 5 4
H Category DC 13 Voltage Ue (V) 24 48 110 220
Current Ie (A) 1 0,8 0,7 0,3

Connection Same polarity for both slow motion and snap action contacts
I Cables entries IPA1, IPA2, IPB1, IPB2 1 x M20
IPA1-P 2 x M20

Order codes ! pg. E.85


Dimensional drawings ! pg. E.91

E.84
Series IP
Foot switches - Contact combinations (per pedal)
Slow break Snap action

Function Cat. no Ref. no. Cat. no Ref. no. Cat. no Ref. no. Cat. no Ref. no. Pack
(1)
N IPA1-N211B 132170 IPA1-N222B 132184 IPA1-N411B 132198 IPA1-N422B 132213 1
ONE pedal P(2) IPA1-P211B 132171 – – – 1
Without guard D – IPA1-D222B 132185 – IPA1-D422B 132214 1
R – – IPA1-R411B 132200 – 1

Foot switches
N IPB1-N211B 132172 IPB1-N222B 132186 IPB1-N411B 132201 IPB1-N422B 132215 1
ONE pedal P(2) IPB1-P211B 132173 – – – 1
With guard D – IPB1-D222B 132187 – IPB1-D422B 132216 1
R – – IPB1-R411B 132203 – 1

N IPA2-N211B 132174 IPA2-N222B 132188 IPA2-N411B 132204 IPA2-N422B 132217 1


TWO pedals P(2) IPA2-P211B 132175 – – – 1
Without guard D – IPA2-D222B 132189 – IPA2-D422B 132218 1

N IPB2-N211B 132176 IPB2-N222B 132190 IPB2-N411B 132206 IPB2-N422B 132219 1


TWO pedals P(2) IPB2-P211B 132177 – – – 1 A
With guard D – IPB2-D222B 132191 – IPB2-D422B 132220 1

B
(1) Function N
Normal operation. When the pedal is pressed the contacts change position. When released they return to their
position.
Function P
C
Press-on press-off operation. The position of the contacts changes each time the pedal is pressed.
Function D
Two-stage operation. Used with two contacts blocks. When the pedal is pressed to the first point, the contacts
of the first block switch; when pressed as far as the second point the contacts of the second block switch and
the first block stays in the same position.
D
Function R
Normal operation with potentiometer. When the pedal is pressed, the contacts change position at the same
time as the potentiometer is operated. When released, the contacts and potentiometer return to their initial
position. E
Positive opening.

(2) Version with function P do not correspond to the concept of positive opening.
F

E.85
Series IP
Safety foot switches

Operation
1 Pedal operation up to the trigger point
Control and signalling units

The operating contact is closed, the operating process is started

2 Operation past the trigger point in emergency cases


The operating contact is opened and latched and the process is stopped.
Also if the device is unused, the latch remains in the off-position in this
phase.
Uncontrolled restart is prevented

3 Reset function
Only after the danger has passed can the contacts be manually un-
latched (push-button on the side). The operating process can now be
restarted by pushing the pedal up to the triggering point.

OFF
Approvals
A
1
ON
B
Features
2
Enclosed in metal with aluminium
C protection cover, safety latch function Emergency
“OFF-ON-OFF” with manual reset.

D 3
Technical data

E Switching diagram
1) Trigger point 1)
2) Latched position

F 2)

Rated insulation voltage Ui max. 400VAC Order codes


G Thermal continuous
current Ithe
max. 10A Cat. no. Ref. no. Pack

Switching frequency max. 50/min. - According to standards: IPSF1 223000 1


Mechanical operational life 10 x 106 EN 60947-1 / IEC 60947-5-1
number of switching cycles - Slow-action contact
H Ambient temperature -30°C to +80°C - Snap-action contact
- Trigger point
Cable conduits (3x) M20x1.5
- Latch function
Protection degree IP65 - Making current according to
Actuating force (approx.) 10N EN/IEC 60947-5-1 AC15/240V/3A
I Trigger point 200N
Weight 1.5 kg

Dimensions ! pg. E.91

E.86
Series
Series
105
IP
Signalling devices
General
Series 105 signalling units are used to indicate the electric equipment power
supply conditions.
For this purpose the devices shall be wired after the main disconnecting switch
and clearly in view when the cabinet´s doors are opened.
Series 105 DTL devices can be used on three-phase lines with or without the
neutral wire or single-phase power lines, indicating the hazardous condition
due to the applied voltage.
Three luminous red lamps are used. The flashing devices are normally used

Signalling devices
in combination with limit switches contacts NC type 114FCT03 that provides
insertion when the cabinet door are open only.

Climatic protection
The standard versions are suitable for use in the following climates:
• Temperate climate cat. 23/50 (DIN 50014)
• Wet climate cat. 23/83 (DIN 50015)
• Hot wet climate cat. 40/92 (DIN 50015)
• Variable wet climate cat. FW 24 (DIN 50016)

Standards
CEI, IEC, VDE, BSI and UTE
A
Approvals
B
UL, CSA and ASE/SEV

Suggested connections
C
Indicates the presence of 3, 2 or 1 phase only by means of the Indicates the presence of 3 or 2 phases by means of the relative lamp. One
relative lamp. phase only is not indicated ( all lamps OFF )

3-phase line with insulated 3-phase line with grounded 3-phase line without neutral
E
Indicates both phases with 3 lamps ON at same time. One phase only is 1. Phase to phase connection on a 3 phase
not indicated ( all lamps OFF ) line with grounded neutral. Indicates the
presence of 2-phases or 1 only with the 3 F
lamps ON at the same time.
2. Phase to neutral connection on a 3 phase
line with grounded neutral or phase to
phase by a matching transformer with one
phase grounded. Indicates the presence of G
the ungrounded phase with the 3 lamps ON
at the same time. No indication occur if the
Single-phase line (general diagram) Single phase-line (alternative ungrounded phase is missing
( all lamps OFF ).
H
Specifications
Temperature ranges Operation
Storage
from -25ºC up to +70ºC
from -40ºC up to +70ºC
I
Degree of protection (according to IEC 529) IP 20
Electrical
Rated insulation voltage according to EN 60947.1
Impulse withstand voltage according to EN 60947.1
690V
4kV
X
Electrical input 2mA max.
Connections Terminal strip with numbered terminals, accessible from outside
protected against accidental contacts according to DIN 57106 and IP 20 according to IEC 529
Clamping capacity Maximum one flexible conductor 12 AWG (3.3mm2)

Order codes ! pg. E.88


Dimensional drawings ! pg. E.90

E.87
Series 105
Flashing devices
Supply voltage
Cat. no Ref. no. Pack
Three-phase Single-phase
(50-60Hz) (50/60Hz)
220V 110-127V 105DTL220 132230 1

380-600V 220-350V 105DTL500 132231 1


Control and signalling units

690V 105DTL690 132232 1

3 pole limit switch for device control


Protection Cables Operation Contacts Cat. no Ref. no. Pack
degree entry force
IP40 PG11 8.5 N min. 3NC 114FCT03 130320 25

IP65 PG11 8.5 N min. 3NC 114FCT03T 130321 25

Paralell bridge for 3 poles limit switches


Cat. no Ref. no. Pack

A 105 PT 132234 50x5

B
Single door protection unit
The unit includes the following components:
C • one flashing device105DTL220 or 105DTL500.
• one 3-pole limit switch 114FCT03 for connection of the flashing device
• one electrical interlock device and panel light 105GIL or 105GIL10.
• one mounting plate 105PM on which are fitted on the above devices.
D If two doors have to be protected (as double enclosure closing on the middle) the mounting
plate shall be fitted also one limit switch114FCT03 and one device 105GIL or 105GIL10.
Approvals:
E UL (USA) - CSA (Canada)
Supply voltage
Cat. no Ref. no. Pack
Three-phase Single-phase Tripping coil
(50-60Hz) (50/60Hz)
F 220V 110-127V Shunt trip 105GP1P220 132250 1
220V 110-127V Undervoltage trip 105GP1P220M 132251 1

380-600V 220-350V Shunt trip 105GP1P500 132252 1


380-600V 220-350V Undervoltage trip 105GP1P500M 132253 1
G

E.88
Series 105
Electrical interlock device and cubicle lighting (1)
The switch can be directly driven by the enclosure door.
If several doors are employed, one switch per door shall be used.
When properly connected, the following functions are provided:
• Position 1 (pushed) door closed: light OFF, tripping coil of main switch unpowered ( normal
equipment operation )
• Position 2. (free) door opening: light ON, tripping coil of main switch powered (equipment
shall cut-out automatically).
• Position 3 (pulled) door open: light ON, tripping coil of main switch unpowered (adjustment
on the equipment of dry checks). When door is closed again, the switch revert automatically
from position 2 or 3 to position 1.
Terminals have IP2X protection degree according to IEC/EN 60529

Signalling devices
Approvals: UL (U.S.A.) - CSA (Canada)

Tripping coil Cat. no Ref. no. Pack

Shunt trip 105 GIL 132240 1

Undervoltage trip 105 GIL 10 132241 1

Electrical interlock device (1) C


The switch is directly driven by the enclosure door.
If several doors are employed, one switch per door is needed.
When properly connected, the same functions of devices above shall be provided but without
enclosure control light. D
Terminals have IP2X protection degree according to IEC 529
Tripping coil Cat. no Ref. no. Pack
E
Shunt trip 105 CI 132242 1

F
Undervoltage trip 105 CI 10 132243 1

H
Mounting plate
Cat. no Ref. no. Pack

105 PM 132244 1
I

X
(1) For electrical performance and features of contact blocks please see E.48

E.89
Series 105 and 101
Dimensional drawings
Series 105 - Flashing devices Series 105 - Single door protection unit
Control and signalling units

Series 105 - Electrical interlock and cubicle lighting Series 105 - 3 pole limit switch for device control

C Series 105 - Electrical interlock device Series 105 - Mounting plate

F
Series 101 - Palm push-buttons
G . . . PM . . . . . . PM . . . P . . . FPM . . .

E.90
Series IP

Series IP - Foot switches without protective guard


One pole Two poles

Foot switches
Series IP - Foot switches with protective guard
One pole Two poles

D
Safety foot switches

E.91

32764_E82_E92_E.indd 91 12-07-2005 14:04:01


Everything is
Electronic relays

Order codes

F.3 Series DM

Single voltage electronic timers. 22.5mm module

F.4 Series NMV

Multivoltage electronic timers. 22.5mm module

F.6 Series D

Single voltage electronic timers. 45mm module

F.7 Liquid level detectors relay

F.8 Earth leakage relays Plug-in relays and Auxiliary contactors A


F.9 Protection relays

F.10 Detection relays Motor protection devices B


F.11 Control and protection relays

F.11 Auxiliary function Contactors and Thermal overload relays C


F.12 Standard suplpy voltages

Technical data Motorstarters D


F.14 Series DM

F.16 Series NMV


Control and signalling units E
F.24 Series D
Electronic relays F

Dimensions
Limit switches G
F.40 Series DM, NMV, D

Speed drive units H

Main switches I

Numerical index X

under control F.1


Series DM, NMV, D
Series DM Single voltage
22.5mm module

Series NMV Multivoltage


22.5mm module

Series D Single voltage


45mm module
Electronic relays

Standards
VDE 0106 CSA C 22.2 Nr.14 UNE 20-119
VDE 0110 UL 94 IEC/EN 60947-5-1
EN 50002 UL 508 IEC/EN 61812-1
EN 50042 IEC 255.5

Range overview
22.5mm module 45mm module
A Series DM Series NMV Series D
Single voltage Multivoltage Single voltage

Delay Pg. Pg. Pg. Pg. Pg. Pg. Pg.

B Delayed ON
ON delay with auxiliary contact
MTC F.3 NMTCV F.4
MMFV F.5
NMTCSV F.4 NMMFV F.5

ON delay + instantaneous contact NMTCIV F.4


OFF delay MRD F.3 NMRDV F.5
OFF delay with auxiliary contact NMTDV F.5 NMMFV F.5
C ON + OFF with auxiliary contact NMMFV F.5
Star-delta starter MET F.3 NMETV F.4 RET50 F.6
Multifunction NMMFV F.5
Impulse
D Delayed ON NMICV F.4 NMMFV F.5
ON delay with auxiliary contact NMMFV F.5
OFF delay with auxiliary contact NMMFV F.5
ON + OFF with auxiliary contact NMMFV F.5
E Intermittence
Symmetric intermittence NMIFV F.5
Asymmetric intermittence NMIVV F.5 NMIVVL F.5
Control
F Motor re-start control relay
Detectors
RCR1 F.7

Liquid level detector relay DINIL F.7


Voltage detector relay RDT F.10
G Current detector relay
Current detector relay with delay
RDI
RDIT
F.10
F.10
Relay
Differential earth leakage RDHT/A F.8
Thermistor relay RS01N F.11
H Adjustable thermistor relay RSR F.11
Frequency control relay RCF F.11
Protection (three-phase lines)
Integral protection relay RDFF1 F.9
I for 3-ph. lines
Unbalance and phase failure RPDF F.9
Phase failure, unbalance and RDMT1 F.9
3-ph min. voltage
X Phase sequence RSF F.9
Phase sequence and phase failure RSFF F.9
Maximum and minimum voltage RTMM F.9
Protection (single-phase lines)
Maximum and minimum voltage RMM F.9

F.2
Series DM
Single voltage electronic timers. 22.5mm module
Supply Voltage Time Available Cat. no (1) Ref. no. Pack
voltage (V) range contacts
Delayed ON relay Direct 220 0.2 - 2 sec 1 changeover MTCAN 122004 1
0.8 - 8 sec.
6 - 60 sec.

Electronic relays of 22.5 mm


50 - 500 sec.
Technical data: see F.14

Star-delta starter relay Direct 2 - 50 sec. 2 changeover METAN 122034 1


With transformer(2) 2 - 50 sec. 2 changeover MET t AN 122045 1
Technical data: see F.15

Delayed OFF relay Direct 220 0.5 - 5 sec. 1 changeover MRD-5AN 122054 1
0.5 - 10 sec. MRD-10AN 122064
0.5 - 50 sec. MRD-50AN 122074
0.5 - 100 sec. MRD-100AN 122084
0.5 - 700 sec. MRD-700AN 122094
Technical data: see F.15

Standard supply voltages ! pg. F.12


Technical data ! pg. F.14
Dimensions ! pg. F.40

F.3
Series NMV
Multivoltage electronic timers. 22.5mm module
Supply Time Available Cat. no (1) Ref. no. Pack
voltage range contacts
Delayed ON relay Direct 0.06 sec - 100 h. 1 changeover NMTCV 124900 1
24-240V AC/DC 0.06 sec - 100 h. 2 changeover NMTCV 2 124901 1
With transformer(2) 0.06 sec - 100 h. 1 changeover NMTCV t © see bottom 1
Technical data: see F.16

Delayed ON with Direct 0.06 sec - 100 h. 1 timed contact NMTCIV 124905 1
instantaneous 24-240V AC/DC 0.06 sec - 100 h. + 1 instant contact
Electronic relays

contact Technical data: see F.17

Delayed ON with Direct 0.2 - 2 sec. Thyristor output NMTCSV 124906 1


thyristor 0.8 - 8 sec.
output timer (3) 6 - 60 sec.
50 - 500 sec.
Technical data: see F.18

B Impulse ON timer Direct 0.06 sec - 100 h. 1 changeover NMICV 124907 1


24-240V AC/DC
Technical data: see F.18
C

D
Star-delta starter Direct 1 - 10 sec. 1 changeover NMETV 124908 1
E 24-240V AC/DC
With transformer(2)
6 - 60 sec.
1 - 10 sec. 1 changeover NMETV t © see bottom 1
6 - 60 sec.
Technical data: see F.19

G (1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and the
frequency of the control circuit, according to the tables on F.12 and F.13
(2) Transformator inside the timerhousing
(3) Not UL approved
H

Standard supply voltages ! pg. F.12


Technical data ! pg. F.16 For reference numbers,
see chapter X, pg. X.14
Dimensions ! pg. F.40

F.4
Series NMV
Multivoltage electronic timers. 22.5mm module (continued)
Supply Time Available Cat. no (1) Ref. no. Pack
voltage range contacts
Delayed OFF timer Direct 0.5 - 6 sec. 1 changeover NMRDV-6 124912 1
24-240V AC/DC 5 - 60 sec. 1 changeover NMRDV-60 124913 1
50 - 600 sec. 1 changeover NMRDV-600 124914 1

Electronic relays of 22.5 mm


0.5 - 6 sec. 2 changeover NMRDV 2-6 124915 1
5 - 60 sec. 2 changeover NMRDV 2-60 124916 1
50 - 600 sec. 2 changeover NMRDV 2-600 124917 1
With transformer(2) 0.5 - 6 sec. 1 changeover NMRDV t-6 © see bottom 1
5 - 60 sec. 1 changeover NMRDV t-60 © see bottom 1
50 - 600 sec. 1 changeover NMRDV t-600 © see bottom 1
Technical data: see F.19

Delayed OFF through Direct 0.06 sec - 100 h 1 changeover NMTDV 124927 1
contact timer 24-240V AC/DC
Technical data: see F.20

Symmetric Direct 0.06 sec - 100 h 1 changeover NMIFV 124928 1


intermittence 24-240V AC/DC
Technical data: see F.20
A

Asymmetric
intermittence,
Direct
24-240V AC/DC
0.06 sec - 100 h 1 changeover NMIVV 124929 1
C
started by Technical data: see F.21
connection
or pause (choice)
D

E
Multifunction - Delayed ON timer - Impulse ON timer
- Delayed ON through contact timer - Impulse ON through contact timer
- Delayed OFF through contact timer - Impulse OFF through contact timer
- Delayed ON and OFF through contact timer - Impulse ON and OFF through contact timer
Module 22,5mm
F
Direct 0.6 sec - 100 h 1 changeover NMMFV 124930 1
24-240V AC/DC

Module 45mm
Direct
24-240V AC/DC
0.6 sec - 100 h H
With transformer 0.6 sec - 100 h 2 changeover NMMFV t 2 © see bottom 1

I
(1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and the
frequency of the control circuit, according to the tables on F.12 and F.13
(2) Transformator inside the timerhousing
X

For reference numbers,


see chapter X, pg. X.14

F.5
Series D
Single voltage electronic timers. 45mm module
Supply Voltage Available Time Cat. no (1) Ref. no. Pack
voltage (V) contacts range
Star-delta starter relay Direct and with 220-230 RET ... 0.5 - 50 sec. RET 50ENU 122534 1
transformer(3) 380-400 1 changeover
Technical data: see F.23

Motor re-start control relay Direct and with RCR 1 0.2 - 2 sec. RCR 1 © see bottom 1
transformer(2) 1 changeover (memory time)
Electronic relays

RCR 1EN 123604 1


RCR 1AJ 123603 1
Technical data: see F.24

Motor re-start Direct and with RCRT 0.2 - 6 sec. RCRT 6 - 60 © see bottom 1
control relay (plug in) transformer(2) 1 changeover (memory time)
0.2 - 60 sec.
(delayed time)
Technical data: see F.24

A
(1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and the
frequency of the control circuit, according to the tables on F.12 and F.13
(2) Possibility of fitting a remote potentiometer.
B (3) Transformator inside the timerhousing

Standard supply voltages ! pg. F.12


Technical data ! pg. F.23 For reference numbers,
see chapter X, pg. X.14
Dimensions ! pg. F.40

F.6
Series D
Liquid level detector relay
Supply Contacts No. of Cat. no. (1) Ref. no. Pack
voltage circuits
With transformer(2) DINIL.... 2 DINIL 02 © see bottom 1
1 changeover 1 DINIL 03 © see bottom 1
DINIL ...E 2 DINIL 02E ENU 123656 1
(plug in) 1 DINIL 03E ENU 123666 1

Electronic relays of 45 mm
1 changeover
11 pins socket for DINIL-02E, -03E. PRCZ11 220647 1
for panel fixing. Front terminals
Technical data: see F.24
F.25 (DINIL 02)
F.26 (DINIL 02E)
F.27 (DINIL 03)
F.28 (DINIL 03E)

Probes Cable union and probe encapsulated and 5 meters SON-1 123680 1
protected by thermoplastic housing. 10 meters SON-2 123690 1
Stainless steel probe.
Without cable. Waterproof and protected with a SON-3 123700 1
thermoplastic housing. Stainless steel probe.

(1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and the
frequency of the control circuit, according to the tables on F.12 and F.13
(2) Transformator inside the timerhousing

For reference numbers,


see chapter X, pg. X.14

F.7
Series D
Earth leakage relays. 45 mm module
Differential transformers Earth leakage relays
Supply Contacts Sensiv. Ø Cat. no (1) Ref. no. Pack Cat. no (1) Ref. no. Pack
voltage (A) (mm) see bottom
Differential earth leakage RDHT 1-... 0.2 - 1.2 35 WKAT 35-1,2A/2V 204165 1 RDHT 1-1,2© 1
relay with hand reset With test 70 WKAT 70-1,2A/2V 204166 1
(with test) 1 changeover 105 WKAT 105-1,2A/2V 204167 1
140 WKAT 140-1,2A/2V 204168 1
210 WKAT 210-1,2A/2V 123900 1
1 - 10 35 WKAT 35-10A/2V 204169 1 RDHT 1-10© 1
70 WKAT 70-10A/2V 204170 1
105 WKAT 105-10A/2V 204171 1
140 WKAT 140-10A/2V 204172 1
210 WKAT 210-10A/2V 204173 1
Technical data: see F.29
Electronic relays

Differential earth leakage Direct and with RDHA 1-... 0.2 - 1.2 35 WKAT 35-1,2A/2V 204165 1 RDHA 1-1,2© 1
relay with automatic reset transformer(2) With test 70 WKAT 70-1,2A/2V 204166 1
(with test) 1 changeover 105 WKAT 105-1,2A/2V 204167 1
140 WKAT 140-1,2A/2V 204168 1
210 WKAT 210-1,2A/2V 123900 1
1 - 10 35 WKAT 35-10A/2V 204169 1 RDHA 1-10© 1
70 WKAT 70-10A/2V 204170 1
105 WKAT 105-10A/2V 204171 1
140 WKAT 140-10A/2V 204172 1
210 WKAT 210-10A/2V 204173 1
Technical data: see F.29

A
(1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and the
frequency of the control circuit, according to the tables on F.12 and F.13
(2) Transformator inside the timerhousing
B

Standard supply voltages ! pg. F.12


For reference numbers,
Technical data ! pg. F.29
see chapter X, pg. X.14
Dimensions ! pg. F.40

F.8
Series D
Protection relays
Supply Contacts Operating range Unbalance Mains Cat. no (1) Ref. no. Pack
voltage contact Umin. Umax. frequency see bottom
Integral protection relay for With RDFF 1-... 5 - 20% 5 - 15% 2.5 - 10% 50 Hz RDFF1-50 © 1
three-phase lines transformer(2) 1 changeover 60 Hz RDFF1-60 © 1
Technical data: see F.30

Electronic relays of 45 mm
Unbalance and phase failure Direct and with RPDF 2-... - - 2.5 - 10% 50 Hz RPDF2-50 © 1
protection relay for transformer(2) 2 changeover 60 Hz RPDF2-60 © 1
three-phase lines Technical data: see F.31

Voltage
Unbalance, phase failure and With RDMT 1-... 0 - 20% 2 - 10% 220V 50 Hz RDMT1-50AN 124044 1
minimum voltage protection transformer(2) 1 changeover 380V RDMT1-50AU 124045
relay for three-phase lines Technical data: see F.32

A
Phase sequence and phase With RSFF 1-... - - - 50 Hz RSFF1-50 © 1
failure protection relay for transformer(2) 1 changeover 60 Hz RSFF1-60 © 1
three-phase lines Technical data: see F.33 B

C
Phase sequence protection With RSF 1-... - - - 50 Hz RSF1-50 © 1
relay for three-phase lines transformer(2) 1 changeover
Technical data: see F.33
60 Hz RSF1-60 © 1 D

Maximum and minimum


voltage protection relay for
With RTMM 2-...
transformer(2) 2 changeover
5 - 20% 5 - 15% - RTMM 2 © 1
F
three-phase lines Technical data: see F.34

Maximum and minimum With RMM 2-... 5 - 20% 5 - 15% - RMM 2 © 1 H


voltage protection relay for transformer(2) 2 changeover
a single-phase lines Technical data: see F.34

(1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and the
X
frequency of the control circuit, according to the tables on F.12 and F.13
(2) Transformator inside the timerhousing

For reference numbers,


see chapter X, pg. X.14

F.9
Series D
Detection relays
Supply Contacts Operating Voltage Input Max. input Cat. no (1) (2) Ref. no. Pack
voltage range drop impedance voltage see bottom

Voltage detector relay Direct and with RDT 2-... 0.1 - 1V - 10 kOhms 40V RDT...1V © 1
transformer(3) 2 changeover 0.5 - 5V - 10 kOhms 60V RDT...-5V © 1
1 - 10V - 20 kOhms 75V RDT...-10V © 1
3 - 30V - 60 kOhms 110V RDT...-30V © 1
12 - 125V - 250 kOhms 300V RDT...-125V © 1
40 - 400V - 800 kOhms 600V RDT...-400V © 1
Direct RDTA 2-... 0.1 - 1V - 10 kOhms 40V RDTA...1V © 1
24V DC 2 changeover 0.5 - 5V - 10 kOhms 60V RDTA...-5V © 1
1 - 10V - 20 kOhms 75V RDTA...-10V © 1
3 - 30V - 60 kOhms 110V RDTA...-30V © 1
12 - 125V - 250 kOhms 300V RDTA...-125V © 1
40 - 400V - 800 kOhms 600V RDTA...-400V © 1
Electronic relays

Technical data: see F.35

Current detector relay Direct and with RDI 2-... 1 - 10A 0.33V 0.033Ohms 12A RDI...10A © 1
transformer(3) 2 changeover 0.5 - 5A 0.25V 0.05Ohms 10A RDI...-5A © 1
0.1 - 1A 0.5V 0.5 Ohms 3A RDI...-1A © 1
20 - 200mA 0.44V 2.2 Ohms 1A RDI...-0,2A © 1
20 - 200mV 1 KOhms 15V RDI...-0,2V © 1
Direct RDIA 2-... 1 - 10A 0.33V 0.033Ohms 12A RDIA...10A © 1
24V DC 2 changeover 0.5 - 5A 0.25V 0.05Ohms 10A RDIA...-5A © 1
0.1 - 1A 0.5V 0.5 Ohms 3A RDIA...-1A © 1
20 - 200mA 0.44V 2.2 Ohms 1A RDIA...-0,2A © 1
20 - 200mV 1 kOhms 15V RDIA...-0,2V © 1
Technical data: see F.36

A
Direct and with RDIT 2-... 1 - 10A 0.33V 0.033Ohms 12A RDIT...10A © 1
Current detector with transformer(3) 2 changeover 0.5 - 5A 0.25V 0.05Ohms 10A RDIT...-5A © 1
B delay (0.5 - 15 sec.) 0.1 - 1A 0.5V 0.5 Ohms 3A RDIT...-1A © 1
20 - 200mA 0.44V 2.2 Ohms 1A RDIT...-0,2A © 1
20 - 200mV 1 kOhms 15V RDIT...-0,2V © 1
Direct RDITA 2-... 1 - 10A 0.33V 0.033Ohms 12A RDITA...10A © 1
24V DC. 2 changeover 0.5 - 5A 0.25V 0.05Ohms 10A RDITA...-5A © 1
C 0.1 - 1A 0.5V 0.5 Ohms 3A RDITA...-1A © 1
20 - 200mA 0.44V 2.2 Ohms 1A RDITA...-0,2A © 1
20 - 200mV 1 kOhms 15V RDITA...-0,2V © 1
Technical data: see F.37
D
(1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and the
frequency of the control circuit, according to the tables on F.12 and F.13
E (2) Versions in 24V DC only with internal galvanic insulation: RDTA..., RDIA..., RDITA...
(3) Transformator inside the timerhousing

Standard supply voltages ! pg. F.12


Technical data ! pg. F.35 For reference numbers,
see chapter X, pg. X.14
Dimensions ! pg. F.40

F.10
Series D
Control and protection relays
Supply Contacts Thermal probe (2) Cat. no (1) Ref. no. Pack
voltage When cold - When hot see bottom

Thermistor relay Direct and with RS01N 1.5 kOhms -2.5 kOhms RS01N © 1
transformer(3) 1 changeover
Technical data: see F.38

Electronic relays of 45 mm
Supply Contacts Thermal range Cat. no (1) Pack
voltage with PT100 probe
Thermistor relay (adjustable) Direct and with RSR 1-... 30 - 60ºC RSR1-30 © 1
transformer(3) 1 changeover 55 - 85ºC RSR1-55 © 1
80 - 110ºC RSR1-80 © 1
105 - 135ºC RSR1-105 © 1
130 - 180ºC RSR1-130 © 1
Technical data: see F.38

Supply Contacts Jumper Setting Cat. no (1) Ref. no. Pack


voltage terminals range see bottom
Frequency control relay With RCF 1-... Without 5 - 15Hz RCF-1 © 1
transformer(3) 1 changeover Y1 - Y2 15 - 45Hz
Y1 - Y3 45 - 135Hz
Technical data: see F.39

B
Auxiliary function
Supply Contacts Cat. no (1) Ref. no. Pack
Instant auxiliary relay
voltage see bottom C
Direct 2 MRI 2 © 1
changeover
Technical data: see F.39
D

E
(1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and the
frequency of the control circuit, according to the tables on F.12 and F.13
(2) Thermal probe resistance not included
(3) Transformator inside the timerhousing F

For reference numbers,


see chapter X, pg. X.14

F.11
Series DM, NMV, D
Standard supply voltages - Direct supply
Current DC DC / AC AC (50/60Hz)

CODES © CD CD CG AJ AN
Voltages 24 24 48 110 220
(V) 125 240

MET
MRD
MRI2
MTC
RCR1
Electronic relays

RDI
RDIA
RDIT
RDITA
RDT
RDTA
RMM
RS01N
RSR1

F.12
Series DM
Standard supply voltages - Supply with transformer
Current. AC (50/60Hz) AC (50Hz) AC (60Hz)

CODES © AD AG AJ AJ AK AM AN EN AU AP AR EU AU AV AX AY ENU AN AR AU AX AY AN AR AU AX AY
24 48 110 110 125 200 220 220 380 230 240 380 380 400 440 500 220-230 220 240 380 440 500 220 240 380 440 500
Voltages
(V) 125 240 230 440 400 380-400

DINIL-02
DINIL-02E
DINIL-03
DINIL-03E
MET t

Electronic relays
NMETV t
NMICV t
NMIFV t
NMMFV t2
NMTCV t
RCF 1
RCR 1
RCRT6-60
RDFF1-50
RDFF1-60
RDH1 A
RDHA1
RDHT1
RDI B
RDIT
RDMT1-50
RDT C
RET50
RIC
RMM D
RPDF...-50
RPDF...-60
RSF1-50 E
RSF1-60
RSFF1-50
RSFF1-60
F
RS01N
RSR1
RTMM
G

F.13
Series DM
MTC... Delayed ON relay
(multirange)

Function Technical characteristics


MTC MTCt
Electronic relay whose output contact connects with a Nr. of changeover contacts 1
determinated adjustable delay from the moment in which Output contacts:
voltages is applied to supply terminals A1-A2. Rated insulation AC (V) 400
voltage Ui DC (V) 250
It is provided with four timing ranges: 0.2 - 2s; 0.8 - 8s; 6
Thermal current Ith (A) 6
- 60s; 50 - 500s. Range selection is carried out through Utilisation AC-15
dip-switches located at front of the relay. Rated voltage Ue (V) 120/240
Time setting through front potentiometer which controls Rated current Ie (A) 2.5/1.3
Electronic relays

and integrated digital circuit. This allows to obtain excellent Utilisation DC-13
accuracy and repeatability Rated voltage Ue (V) 110/220
Rated current Ie (A) 0,2/0,1
Supply voltages (Un)
AC (direct) (V) 220-240
AC (with transformer) (V) - 380-400
Frequency (Hz) 50/60
Permissible supply voltage variation (%) +10 / -15
Consumption 60 mA 3.5 VA
Input circuit test voltage (kV) 4
(between input, output circuits and
earth)
Switch ON response time (s) 0.2 - 500
Switch OFF response time (ms) 100
A Reset time between 2 cycles (1) (ms) 100
Repeat accuracy with 0.85 - 1.1 Un(%) 2

I
(1) Reset time: Time that must go by from the
X relay ends an operation until it is able to
Ambient conditions Conformity to standards initiate the next one without error.
Storage temperature -10°C to +85°C VDE 0106 CSA C 22.2 No 14 Remark
Operating temperature -5°C to +50°C VDE 0110 IEC/EN 60255-5 STD relays have one red LED that lights up when
Relative humidity 95% (without EN 50002 UL 94 (MTC...) the output contact is made.
condensation) MTC relays have one red LED that lights when the
EN 50005 UL 508 (MTC...) output contact is made and one green LED that
Max. operating altitude 2.000 m
EN 50042 lights when is energized. Relays ...-t have only
Degree of protection IP40; terminals IP20
one red LED that lights when the output contacts
Operating positions Any position is made.

F.14

32764_F14_F42_E.indd 14 12-07-2005 16:03:17


Series DM
MET... Star-delta starter relay MRD... Delayed OFF relay
Function Function
Electronic steped timing relay designed for star-delta Electronic relay whose output contact connects

Electronic relays of 22.5 mm


starting operation control. By applying the supply voltage instantaneously when supply voltage is applied to
to terminals A1-A2 the star contact (17-18) closes dur- terminals A1-A2 , disconnecting with an adjsutable delay
ing an adjustable time between 2 and 50 s., at the end of from the moment in which the supply is switched off.
which it opens, then take place a pause period and delta
contact
(17-28) connects. The standars pause time is about 100ms,
but higher times are on request.
Time setting by means of front potentiometer which
controls and integrated digital circuit. This allows to obtain

Technical characteristics A
MRD
Nr. of changeover contacts 1
Output contacts:
Rated insulation AC (V) 400 B
voltage Ui DC (V) 250
Technical characteristics Thermal current Ith
Utilisation AC-15
(A) 6

MET MET t Rated voltage Ue (V) 120/240 C


Nr. of changeover contacts 2 Rated current Ie (A) 2.5/1.3
Output contacts: Utilisation DC-13
Rated insulation AC (V) 400 Rated voltage Ue (V) 110/220
voltage Ui
Thermal current Ith
DC (V)
(A)
250
6
Rated current Ie (A) 0,2/0,1 D
Supply voltages (Un)
Utilisation AC-15 AC (direct) (V) 220-240
Rated voltage Ue (V) 120/240 120/240 Frequency (Hz) 50/60
Rated current Ie
Utilisation DC-13
(A) 2.5/1.3 2/1 Permissible supply voltage variation(%)
Consumption (mA)
+10 / -15
80
E
Rated voltage Ue (V) 110/220 110 Input circuit test voltage (kV) 4
Rated current Ie (A) 0.2/0.1 0,1 (between input, output circuit and
Supply voltages (Un)
AC (direct) (V) 220-240 -
earth)
Switch ON response time (ms) 250 (2)
F
DC (V) - 380-400 Switch OFF response time (s) 0.5 - 700
Frequency (Hz) 50/60 Reset time between 2 cycles (1) (ms) 250
Permissible supply voltage variation (%) +10 / -15
Consumption 60 mA 3.5 VA
Repeat accuracy with 0.85 - 1.1 Un (%) 2
G
Input circuit test voltage (kV) 4
(between input, output circuits and
earth)
Switch ON response time (ms) 100 H
Reset time between 2 cycles (1) (ms) 100
Repeat accuracy with 0.85 - 1.1 Un (%) 2

X
Ambient conditions Conformity to standards (1) Reset time: Time that must go by from the
relay ends an operation until it is able to
Storage temperature -10°C to +85°C VDE 0106 CSA C 22.2 No 14 initiate the next one without error.
Operating temperature -5°C to +50°C VDE 0110 IEC/EN 60255-5 (2) For 24V DC = 300ms
Relative humidity 95% (without EN 50001 (MET) UL 94
condensation) EN 50002 UL 508
Max. operating altitude 2.000 m
EN 50005 (MRD)
Degree of protection IP40; terminals IP20
EN 50042
Operating positions Any position

F.15

32764_F14_F42_E.indd 15 12-07-2005 16:03:17


Series DM
NMTCV... Delayed ON timer
Function Technical characteristics
NMTCV NMTCV2 NMTCVt
Electronic relay whose output contact connects with a cer- Nr. of changeover contacts 1 2 1
tain adjustable delay from the moment voltage is applied Output contacts:
to supply terminals A1-A2. Rated insulation AC (V) 250
It has four timing ranges : see drawing. voltage Ui DC (V) 250
Thermal current Ith (A) 6 6 6
Range selection is made by dipswitches located on the
Utilisation AC-15
front of the relay. Times are set by front potentiometer Rated voltage Ue (V) 120/230
controlling an Application Specific Integrated Circuit (ASIC) Rated current Ie (A) 2.5/1.3
specially designed for this group of relays. This allows for Utilisation DC-13
Electronic relays

excellent precision and repeatability features. Rated voltage Ue (V) 110/230


Rated current Ie (A) 0.2/0.1
Supply voltages (Un)
DC/AC (direct) (V) 24-240 24-240 -
AC(with transformer) (V) - - 110-125
200-240
380-440
Frequency (Hz) 50/60
Supply voltagetolerance (%) +10 / -20 +10 / -20 +10 / -15
Consumption (mA) 60 ( 24V) 60 (24V) -
(mA) 15 ( 240V) 15 (240V) -
(VA) - - 3.5
Input circuit test voltage (kV) 2 4 4
(between input, output and group
A circuits)
Switch ON response time 0.06s - 100 h.
Switch OFF response time (ms) 150
Reset time between 2 cycles (1) (ms) 100

B Repeat accuracy with 0.85 - 1.1 Un (%) 1

X
Ambient conditions Conformity to standards (1) Reset time: Time that must go by from the
relay ends an operation until it is able to
Storage temperature -40°C to +80°C VDE 0106 CSA C 22.2 No 14 initiate the next one without error.
Operating temperature -25°C to +60°C VDE 0110 IEC/EN 60255-5
Relative humidity 95% (without EN 50002 UL 94 Remark
condensation) The relay has a green LED that lights when the
EN 50042 UL 508 relay is energised ( flashing during the timing )
Max. operating altitude 2.000 m and a red LED that lights when output contact
IEC/EN 60947-5-1 UNE 20-119
Degree of protection IP40; terminals IP20 is made.
Operating positions Any position

F.16

32764_F14_F42_E.indd 16 12-07-2005 16:03:17


Series NMV
NMTCIV... Delayed ON timer with
instantaneous contact
Function

Electronic relays of 22.5 mm


Electronic relay with two output contacts. One contact
connects instantly when voltage is applied to the supply
terminals A1-A2, and the other connects with a certain
adjustable delay.
It has four timing ranges : see drawing.
Range selection is made by dip-switches located on the
front of the relay.
Times are set by front potentiometer controlling an ASIC
specially designed for this group of relays. This allows for
excellent precision and repeatability features.

B
Technical characteristics
NMTCIV
Nr. of changeover contacts 2 C
Output contacts:
Rated insulation AC (V) 250
voltage Ui DC (V) 250
Thermal current Ith
Utilisation AC-15
(A) 6
D
Rated voltage Ue (V) 125/230
Rated current Ie (A) 2.5/1.3
Utilisation DC-13
Rated voltage Ue (V) 110/230
E
Rated current Ie (A) 0.2/0.1
Supply voltages (Un)
AC/DC (direct)
Frequency
(V)
(Hz)
24-240
50/60 F
Permissible supply voltage variation (%) +10 / -20
Consumption (mA) 60 (to 24V)
(mA) 15 (to 240V)
Input circuit test voltage (kV) 2 G
(between input, output circuits and
earth)
Switch ON response time 0.065s - 100 h.
Switch OFF response time (ms) 150 H
Reset time between 2 cycles (1) (ms) 100
Repeat accuracy with 0.85 - 1.1 Un 1

X
Ambient conditions Conformity to standards (1) Reset time:T ime that must go by from the
relay ends an operation until it is able to
Storage temperature -40°C to +80°C VDE 0106 CSA C 22.2 No 14 initiate the next one without error.
Operating temperature -25°C to +60°C VDE 0110 IEC/EN 60255-5
Relative humidity 95% (without EN 50001 (MTCCV) UL 94 Remark
condensation) The relay has a green LED that lights when the
EN 50002 UL 508 relay is energised ( flashing during the timing )
Max. operating altitude 2.000 m EN 50042 (NMTCIV) UNE 20-119 (MTCIV) and a red LED that lights when output contact
Degree of protection IP40; terminals IP20 IEC/EN 60947-5-1 (NMTCIV) is made.
Operating positions Any position

F.17

32764_F14_F42_E.indd 17 12-07-2005 16:03:18


Series NMV
NMTCSV... Delayed ON with NMICV... Impulse ON timer
thyristor output timer
Function
Function
Electronic relay whose output contact connects when
Connection timed electronic relay with thyristor output. voltage is applied to supply terminals A1-A2. It goes back
Change is connected in series with the relay and receives to stand-by after a preset time.
voltage a little while after applying voltage to the relay. It has four timing ranges: see drawing.
This time may be adjusted by a front potentiometer within Range selection is made by dip-switches located on the
one of the four possible ranges by dip-switches: see draw- front of the relay. Times are set by front potentiometer
controlling an ASIC specially designed for this group of
relays. This allows for excellent precision and repeatability
Electronic relays

features.

Technical characteristics
A Utilisation
NMTCSV

Rated current (V) 1 Technical characteristics


Max. non-repetitive current (A) 25 NMICV

B (10ms)
Minimum charge (mA) 10
Nr. of changeover contacts
Output contacts:
1

Supply voltages (Un) Rated insulation AC (V) 250


AC/ DC (direct) (V) 24-240 voltage Ui DC (V) 250
Frequency (Hz) 50/60
C Supply voltage tolerance (%) +10 / -20
Thermal current Ith
Utilisation AC-15
(A) 6

Consumption (mA) 5 Rated voltage Ue (V) 125/230


Switch ON response time (s) 0.2 - 500 (adjustable) Rated current Ie (A) 2,5/1,3
Switch OFF response time (ms) 50 Utilisation DC-13
D Reset time between 2 cycles(1) (ms) 100 Rated voltage Ue (V) 110/230
Repeat accuracy with 0,85 - 1,1 Un(%) 2 Rated current Ie (A) 0,2/0,1
Internal drop voltage (V) <3 Supply voltages (Un)
AC/DC (direct) (V) 24-240
E AC(with transformer) (V) -
Frequency (Hz) 50/60
Supply voltage tolerance (%) +10 / -20
Consumption (mA) 60 (at 24V)
F (mA) 15 (at 240V)
(VA) -
Input circuit test voltage (kV) 2
(between input, output and ground
G circuits)
Switch ON response time (ms) 100
Switch OFF response time 0,065 s - 100 h.
Reset time between 2 cycles (1) (ms) 100

H Repeat accuracy with 0.85 - 1.1 Un(%) 1

X
Ambient conditions Conformity to standards (1) Reset time: Time that must go by from the
relay ends an operation until it is able to
Storage temperature -40°C to +80°C VDE 0106 CSA C 22.2 No 14 initiate the next one without error.
Operating temperature -25°C to +60°C VDE 0110 IEC/EN 60255-5
Relative humidity 95% (without Remark
EN 50002 UL 94 The relays have a green LED that lights up when
condensation)
EN 50042 UL 508 the relays is energised ( flashing during the
Max. operating altitude 2.000 m
IEC/EN 60947-5-1 UNE 20-119 timing) and a red LED that lights up when outlet
Degree of protection IP40; terminals IP20 contact is made.
Operating positions Any position

F.18

32764_F14_F42_E.indd 18 12-07-2005 16:03:18


Series NMV

NMETV... Star-delta starter timer NMRDV... Delayed OFF timer


Function Function
Electronic relay timed in steps whose purpose is to control Electronic relay whose output contact instantly connects

Electronic relays of 22.5 mm


star-delta starting. When supply voltage is applied to the when supply voltage is applied to terminals A1-A2. It
A1-A2 terminals, the star contact (17-18) closes for an disconnects with an adjsutable delay as from the moment
adjustable time between up to 100 h (selectable) the relay loses supply voltage. There are several types
When this time is up, it opens, there is a pause and then the depending on the range of timers.
delta contact connects (17-18). The standard pause time is
about 100ms.
Times are set by front potentiometer controlling an ASIC
specially designed for this group of relays. This allows for
excellent precision and repeatability features.

Technical characteristics
NMRDV NMRDV2 NMRDV t
Nr. of changeover contacts 1 2 1
Output contacts: A
Rated insulation AC (V) 250
voltage Ui DC (V) 250
Thermal current Ith (A) 6
Technical characteristics Utilisation AC-15 B
METV METV t Rated voltage Ue (V) 125/230
Rated current Ie (A) 2.5/1.3
Nr. of changeover contacts 2
Utilisation DC-13
Output contacts:
Rated insulation AC (V) 250
Rated voltage Ue
Rated current Ie
(V)
(A)
110/230
0.2/0.1
C
voltage Ui DC (V) 250
Supply voltages (Un)
Thermal current Ith (A) 6
AC/DC (direct) (V) 24-240 24-240 -
Utilisation AC-15
Rated voltage Ue (V) 125/230
AC(with transformer) (V) - - 110-127
200-240
D
Rated current Ie (A) 2.5/1.3
380-440
Utilisation DC-13
Frequency (Hz) 50/60
Rated voltage Ue (V) 110/230
Rated current Ie
Supply voltages (Un)
(A) 0.2/0.1
Supply voltage tolerance
Consumption
(%) +10 / -20 +10 / -20 +10 / -15
(mA) 60 (at 24V) 1,5 (at 24V) - E
(mA) 15 (at 240V) 5 (at 240V) -
AC/DC (direct) (V) 24-240 -
(VA) - - 3.5
AC(with transformer) (V) - 110-125
Test voltage (kV) 4
200-240
380-440
(between input, output and ground ) F
Switch ON response time (ms) 250 (2)
Frequency (Hz) 50/60
Switch OFF response time 0.5 - 600
Supply voltage tolerance (%) +10 / -20 +10 / -15
Reset time between 2 cycles (1) (ms) 250
Consumption (mA)
(mA)
50 (at 24V)
12 (at 240V)
-
-
Repeat accuracy with 0.85 - 1.1 Un(%) 5 G
(VA) - 3.5
Test voltage (kV) 4
(between input, output and ground )
Switch ON response time (ms) 100 H
Reset time between 2 cycles (1) (ms) 100
Repeat accuracy with 0.85 - 1.1 Un(%) 2

X
Ambient conditions Conformity to standards (1) Reset time: Time that must go by from the
relay ends an operation until it is able to
Storage temperature -40°C to +80°C VDE 0106 CSA C 22.2 No 14 initiate the next one without error.
Operating temperature -25°C to +60°C VDE 0110 IEC/EN 60255-5 (2) For 24V c.c. = 300ms
Relative humidity 95% (without EN 50001 (NMETV) UL 94
condensation) Remark
EN 50002 UL 508 METV relays have a green LED that lights up
Max. operating altitude 2.000 m when the relays is energised ( flashing during the
EN 50042 (NMRDV) UNE 20-119 (NMRDV)
Degree of protection IP40; terminals IP20 timing) and a red LED that lights up when the star
Operating positions Any position IEC/EN 60947-5-1 (NMRDV)
contact 17-18 is closed.

F.19

32764_F14_F42_E.indd 19 12-07-2005 16:03:18


Series NMV
NMTDV... Delayed OFF NMIFV... Symmetric intermittence
through contact timer
Function
Function
Electronic relay whose output contact connects and
Electronic relay whose output contact connects instantly disconnects intermittenly with a symmetric cycle
when connecting the Y1-Y2 terminals with a voltage free (connection and pause timer or the same).
control. It disconnects with an adjustable delay when the It has four ranges: see drawing.
terminals are disconnected. The relay must be supplied Range selection is made by dip-switches located on front
with nominal voltage between A1-A2. Loss of supply of the relay. Times are set by front potentiometer
voltages causes immediate disconnection. controlling an ASIC specially designed for this group of
It has timing ranges: see drawing. Range selection is made relays. This allows for excellent precision and repeatability
Electronic relays

by dip-switches located on front of the relay. Times are features.


set by front potentiometer controlling an ASIC specially
designed for this group of relays. This allows for excellent
precision and repeatability features.

A
Technical characteristics
Technical characteristics NMIFV
B NMTDV Nr. of changeover contacts 1
Output contacts:
Nr. of changeover contacts 1
Rated insulation AC (V) 20
Output contacts:
voltage Ui DC (V) 250
C Rated insulation
voltage Ui
AC (V) 250
DC (V) 250
Thermal current Ith (A) 6
Utilisation AC-15
Thermal current Ith (A) 6
Rated voltage Ue (V) 125/230
Utilisation AC-15
Rated current Ie (A) 2,5/1,3
D Rated voltage Ue
Rated current Ie
(V) 125/230
(A) 2.5/1.3
Utilisation DC-13
Rated voltage Ue (V) 110/230
Utilisation DC-13
Rated current Ie (A) 0,2/0,1
Rated voltage Ue (V) 110/230
Supply voltages (Un)
E Rated current Ie
Supply voltages (Un)
(A) 0,2/0,1
AC/DC (direct)
AC(with transformer)
(V) 24-240
(V) -
AC/DC (direct) (V) 24-240
Frequency (Hz) 50/60
AC(with transformer) (V) -
Supply voltage tolerance (%) +10 / -20
Frequency (Hz) 50/60
F Supply voltage tolerance (%) +10 / -20
Consumption (mA) 50 (at 24V)
(mA) 15 (at 240V)
Consumption (mA) 60 (at 24V)
(VA) -
(mA) 1,5 (at 240V)
Test voltage (kV) 4
(VA) -
G Test voltage (kV) 4
(between input, output and ground
circuits )
(between input, output and ground
Intermittent switch times 0,6s - 100 h.
circuits)
Reset time between 2 cycles (1) (ms) 100
Switch ON response time (ms) 100
H Switch OFF response time 0.065 s - 100 h.
Repeat accuracy with 0.85 - 1.1 Un(%) 2

Reset time between 2 cycles (1) (ms)


Repeat accuracy with 0.85 - 1.1 Un(%) 250
Voltage at open Y1-Y2 (V c.c.) 1
I control contact terminals
Current through control contact
5

Initial (mA) 15
Permanent (mA) 1

X
Ambient conditions Conformity to standards (1) Reset time: Time that must go by from the
relay ends an operation until it is able to
Storage temperature -40°C to +80°C VDE 0106 CSA C 22.2 No 14 initiate the next one without error.
Operating temperature -25°C to +80°C VDE 0110 IEC/EN 60255-5
Relative humidity 95% (without Remark
EN 50001 (MTDV) UL 94
condensation) The relays have a green LED that lights up when
EN 50002 UL 508 the relays is energised (flashing during the timing)
Max. operating altitude 2.000 m
EN 50042 (MIFV) UNE 20-119 (MIFV) and a red LED that lights up when output contact
Degree of protection IP40; terminals IP20 is made.
IEC/EN 60947-5-1 (MIFV)
Operating positions Any position

F.20

32764_F14_F42_E.indd 20 12-07-2005 16:03:19


Series NMV
NMIVV... Asymmetric intermittence,
started by connection or pause (choice)

Function Technical characteristics


NMIVV

Electronic relays of 22.5 mm


NMIVVL
Electronic relay whose output contact connects and
Nr. of changeover contacts 1
disconnects intermittently. Connection and pause times
Output contacts:
may be separately. The intermittency cycle begins a Rated insulation AC (V) 250
connection or disconnection selected by a dip-switches voltage Ui DC (V) 50
and start the instant connection is made from supply Thermal current Ith (A) 6
voltage to the A1-A2 terminals. A new step is begun if Utilisation AC-15
voltage supply is interrumped during operation. Rated voltage Ue (V) 125/230
Rated current Ie (A) 2,5/1,3
It has four timing ranges ;
Utilisation DC-13
MIVV : 0,6 sec - 100 h Rated voltage Ue (V) 110/230
Range selection is made by dip-switches located on the Rated current Ie (A) 0,2/0,1
front of the relay. Times are set by front potentiometer an Supply voltages (Un)
ASIC specially designed for this group of relays. This allows AC/DC (direct) (V) 24-240
for excellent precision and repeatability features. Frequency (Hz) 50/60
Supply voltage tolerance (%) +10 / -20
Consumption (mA) 60 (at 24V)
(mA) 15 (at 240V)
(VA) -
Test voltage (kV) 2
(between input, output and ground
circuits )
Switch ON response time (ms) 150 A
Intermittent switch ON times (2) 0,6 s - 100 h.
Intermittent switch ON times (2) 0,6 s - 100 h.
Reset time between 2 cycles (1) (ms) 150
Repeat accuracy with 0.85 - 1.1 Un(%) 1 B

(1) Reset time: Time that must go by from the re- X


Ambient conditions Conformity to standards lay ends an operation until it is able to initiate
the next one without error.
Storage temperature -40°C to +80°C VDE 0106 CSA C 22.2 No 14
(2) Connection and pause times be set within
Operating temperature -25°C to +60°C VDE 0110 IEC/EN 60255-5 different ranges.
Relative humidity 95% (without EN 50002 UL 94
condensation) Remark
EN 50005 UL 508
Max. operating altitude 2.000 m These relays has a green LED that lights up when
EN 50042 UNE 20-119 the relays is energised (flashing during the timing)
Degree of protection IP40; terminals IP20
IEC/EN 60947-5-1 and a red LED that lights up when output contact
Operating positions Any position is made.

F.21

32764_F14_F42_E.indd 21 12-07-2005 16:03:19


Series NMV
NMMFV... Multifunction relay
Function Technical characteristics
NMMFV NMMFV t2
The functions of this multifunction and multirange Nr. of changeover contacts 1 2
electronic relay are selected by 3 dip-switches located on Output contacts:
the front of the relay. It has eight functions: delayed ON Rated insulation AC (V) 250
voltage Ui DC (V) 250
timer, delayed ON through contact timer, delayed OFF
Thermal current Ith (A) 6
through contact timer, delayed ON and OFF through con- Utilisation AC-15
tact timer, impulse ON timer, impulse ON through contact Rated voltage Ue (V) 110/230
timer, impulse OFF through contact timer, impulse ON and Rated current Ie (A) 2.5/1.3
OFF through contact timer. If the relay loses current during Utilisation DC-13
Electronic relays

timing, it disconnects and is ready for a new cycle. Rated voltage Ue (V) 110/230
Rated current Ie (A) 0.2/0.1
It has four timing ranges: see drawing.
Supply voltages (Un)
Range selection is made by dip-switches located on front AC/DC (direct) (V) 24-240 -
of the relay. AC(with transformer) (V) - 110-125
Times are set by front potentiometer controlling an ASIC 200-240
specially designed for this group of relays. This allows for 380-440
excellent precision and repeatability features. Frequency (Hz) 50/60
Supply voltage tolerance (%) +10 / -20 +10 / -15
Consumption (mA) 60 (at 24V) -
(mA) 15 (at 240V) -
(VA) - 3
Test voltage (kV) 2
(between input, output and ground
A circuit )
Switch ON response time 0.065 s - 100 h.
Switch OFF response time 0.065 s - 100 h.
Reset time between 2 cycles (1) (ms) 150

B Repeat accuracy with 0.85 - 1.1 Un(%)


Voltage open Y1-Y2 (V DC)
1
5
control contact terminals
Current through control contact

C Initial
Permanent
(mA)
(mA)
15
1

X
Ambient conditions Conformity to standards (1) Reset time: Time that must go by from the
relay ends an operation until it is able to
Storage temperature -40°C to +80°C VDE 0106 CSA C 22.2 No 14 initiate the next one without error.
Operating temperature -25°C to +60°C VDE 0110 IEC/EN 60255-5
Relative humidity 95% (without Remark
EN 50002 UL 94
condensation) The relays have a green LED that lights up when
EN 50042 UL 508 the relays is energised (flashing during the timing)
Max. operating altitude 2.000 m
IEC/EN 60947-5-1 UNE 20-119 and a red LED that lights up when output contact
Degree of protection IP40; terminals IP20 is made.
Operating positions Any position

F.22

32764_F14_F42_E.indd 22 12-07-2005 16:03:19


Series D
RET-50... Star-delta starter relay
Function
Electronic steped timer designed to control star-delta
operations. With supply voltage, star contact will close
during an adjustable time between 0,5 - 50 sec. after

Electronic relays of 45 mm
which it will connect delta contact. Standard pause time is
between 100-150 ms.
Terminals voltage supply:
-Single voltage types: A1 and A2
-Two voltage types: A1 and A2 fir 380V AC, A2 and A3 for
220V AC.

Technical characteristics
RET-50 B
Nr. of changeover contacts 2
Output contacts:
Rated insulation
voltage Ui
AC (V)
DC (V)
400
250 C
Thermal current Ith (A) 6
Utilisation AC-15
Rated voltage Ue (V) 120/240
Rated current Ie (A) 2.5/1.3 D
Utilisation DC-13
Rated voltage Ue (V) 110/220
Rated current Ie (A) 0.2/0.1
Supply voltages (Un) E
AC (with transformer) (V) 380-400 /220-230 (two voltages)
Frequency (Hz) 50/60
Permissible supply voltage variation (%) +10 / -15
Consumption
Input circuit test voltage
(VA)
(kV)
3 F
4
(between input, output circuit and
earth)
Switch ON response time (ms)
Reset time between 2 cycles (1) (ms)
100
100
G
Repeat accuracy with 0.85 - 1.1 Un(%) 2

X
Ambient conditions Conformity to standards (1) Reset time: Time that must go by from the
relay ends an operation until it is able to
Storage temperature -10°C to +85°C VDE 0106 IEC/EN 60947-5-1 initiate the next one without error.
Operating temperature -5°C to +50°C EN 50001 UNE 20-119
Relative humidity 95% (without Remark
EN 50005
condensation) Relay RTC...has one LED that lights up when the
EN 50011 output contact is made.
Max. operating altitude 2.000 m
DIN 46199
Degree of protection IP40; terminals IP20
Operating positions Any position

F.23

32764_F14_F42_E.indd 23 12-07-2005 16:03:20


Series D
RCR... Motor re-start control relay RCRT...
The relay is used for instantaneous or delayed motor
startup after a short-time power failure (max. 6 sec). The
RCRT... Motor re-start control relay start ocurrs immediately if power supply is disrupted for
(plug-in) less than 0.2 sec. If the power failure lasts longer, the relay
activates its memory for a time that can be set to 0.2 to 6
Function sec, after which no automatic restart is possible. If power
supply is restored while the memory period is elapsing, the
relay commands a motor restart with a delay time from
RCR...
power supply restoration that can be set to 0.2 to 60 sec. A
This electronic relay performs the function of normal stop-run
system stop cancels the memory function after 50 ms, and
having in addition a system to detect supply voltage fault
therefore the stop signal should be on for at least this time.
which allows to return to the condition when the duration
The relay is non-sensitive to any control voltage fluctuation
of the fault does not exeed the preset time, which can be
Electronic relays

or disruption during or after the motor stop.


adjusted between 0.2 and 2 seconds.
Terminals A1-A2 must be connected to control voltage. As
many stop contacts are necessary can be inserted in series
between terminals Y1-Y2 and between Y2-Y3 in paralell
with star-contacts.
RCR relays are basically used for continuous process
control, where a stop as a result of a short power failure
could cause

B Technical characteristics
RCR 1 RCRT 6-60
Nr. of changeover contacts 1

C Output contacts:
Rated insulation AC (V) 400
voltage Ui DC (V) 250
Thermal current Ith (A) 6

D Utilisation AC-15
Rated voltage Ue (V) 120/240
Rated current Ie (A) 2.5/1.3
Utilisation DC-13
Rated voltage Ue (V) 110/220
E Rated current Ie (A) 0.2/0.1
Supply voltages (Un)
AC (with transformer) (V) 380-400, 240, 220-230, 125
110, 48 (1)
F DC / AC (direct) (V) 24
Frequency (Hz) 50/60
Permissible supply voltage variation +10 / -15
(%)
G Repeat accuracy with 0.85 - 1.1 Un(%)
Consumption (VA)
2
3
Input circuit test voltage (kV) 4
(between input, output circuit and
H earth)
Switch ON response time (ms) 100
Power failure detection level - 0.8 Us
Reset ime (stop) (ms) 100 50 - 75

I Memory reset time


Max. restart delay time
(ms)
(s)
-
-
100
0.2 - 60
Max. memory time (s) 2 0.2 - 6
(1) RCR: only 220V-110V

X
Ambient conditions Conformity to standards Remark
The relay has one LED that lights up when the
Storage temperature -10°C to +85°C VDE 0106 IEC/EN 60947-5-1 contact is made.
Operating temperature -5°C to +50°C EN 50001 UNE 20-119
Relative humidity 95% EN 50005
(without condensation) EN 50011
Max. operating altitude 2.000 m
DIN 46199
Degree of protection IP40; terminals IP20
Operating positions Any position

F.24

32764_F14_F42_E.indd 24 12-07-2005 16:03:21


Series D
DINIL 02 Liquid level detector DINIL-02 - Filling Control

relay for simultaneous


control of well and tank
Functions TANK

Electronic relays of 45 mm
DINIL-02 are conducting liquid level cheking device which
can perform the following functions:
Filling control: The contact between 11-14 closes when
the tank to be cheked drops below a minimum, fixed by the
position of probe Z23, which starts up the pumping system.
When the maximum filling level is reached, fixed by the po-
sition of probe Z22, the contact between 11-14, opens and
the pumping system stops. For the filling control the two
well probes must be connected externally to the common
one (condition of full well). DINIL-02 - Draining control
Draining control: The contact 11-14 (DINIL-02) closes if the
level liquid goes above a maximum, fixed by the position
of probe Z12, which starts up the drain pumping system.
When the level drops below a minimum, fixed by the posi-
tion of probe Z13 the contact 11-14 opens and stop the
pumping system, which prevents the pumpo from losing
its prime.
Simultaneous filling and draining control: The system
starts up whenever the tank requires liquid and the well A
has sufficient level to supply it, and it stops when the liquid
reaches its maximum level in the tank or, as the case may
be, the well reaches its minimum level.
WELL
B
Remark: In all the above applications, the contact between
11-14 is used as a permanent contact for starting and
stopping the pump starter, whether this is DOL, star-delta C
or any other type of starter. DINIL-02 - Simultaneous filling and draining control

Technical characteristics D
DINIL-02
Nr. of changeover contacts 1
Output contacts:
Rated insulation AC (V) 400 TANK E
voltage Ui DC (V) 250
Thermal current Ith (A) 6
Utilisation AC-15
Rated voltage Ue (V) 120/240 F
Rated current Ie (A) 2.5/1.3
Utilisation DC-13
Rated voltage Ue (V) 110/220
Rated current Ie (A) 0.2/0.1
WELL
G
Supply voltages (Un)
AC (with transformer) 380-400,240,220-230,125,110,48,24
Frequency (Hz) 50/60
Permissible supply voltage variation +10 / -15 H
Repeat accuracy with 0.85-1.1 Un (%)
Consumption (VA)
2
3
Ambient conditions
Input circuit test voltage (kV) 4 Storage temperature -10°C to +85°C
(between input, output circuit and
earth)
Operating temperature
Relative humidity
-5°C to +50°C
95% (without condensation)
I
Voltage between probes (V ef.) 6 - 18 Maximum operating altitude 2.000 m
and common Degree of protection IP40; terminals IP20
Max. consumption of probes (mA ef.)
Max.resistance between (kOhms)
0,18
200
Operating positions Any X
probes (resistance of controlled liquid)
Switch ON response time (s) 1
Switch OFF response time (s) 1
Conformity to standards
VDE 0106 EN 50011 UNE 20119 EN 50001
DIN 46199 EN 50005 IEC/EN 60947-5-1
Remark
The relay has one LED that lights up when the output contact is made.

F.25

32764_F14_F42_E.indd 25 12-07-2005 16:03:21


Series D
DINIL 02E Liquid level detector DINIL-02E - Filling control

relay for simultaneous


control of well and tank
Functions
Plug-in devices for control of level of conductive liquids TANK
which can perform the following functions:
Filling control: The contact between 1 and 3 sloses when
the tank to be cheked drops below a minimum, fixed by the
position of probe 6, which starts up the pumping system.
When the maximum filling level is reached, fixed by the po-
Electronic relays

sition of probe 7, the contact between 1 and 3, opens and


the pumping system stops. For the filling control the two
well probes must be connected externally to the common
one (condition of full well).
Draining control: The contact 1-3 closes if the level liquid DINIL-02E - Draining control
goes above a maximum, fixed by the position of probe 9,
which starts up the drain pumping system. When the level
drops below a minimum, fixed by the position of probe
8 the contact 1-3 opens and stop the pumping system,
which prevents the pumpo from losing its prime.
Simultaneous filling and draining control: The system
starts up whenever the tank requires liquid and the well
A has sufficient level to supply it, and it stops when the liquid
reaches its maximum level in the tank or, as the case may
be, the well reaches its minimum level.
B
Remark: In all the above applications, the contact between WELL
1-3 is used as a permanent contact for starting and stop-
ping the pump starter, whether this is DOL, star-delta or
C any other type of starter.

Control voltage: Single voltage: Two voltages: DINIL-02E - Simultaneous filling and draining control
terminals 2-10 terminals 2-10 (220 VAC)
D terminals 2-11 (380 VAC)

Technical characteristics
E DINIL-02E
Nr. of changeover contacts 1
Output contacts: TANK

F Rated insulation
voltage Ui
AC
DC
(V)
(V)
400
250
Thermal current Ith (A) 6
Utilisation AC-15
Rated voltage Ue (V) 120/240
G Rated current Ie (A) 2.5/1.3
Utilisation DC-13 WELL
Rated voltage Ue (V) 110/220
Rated current Ie (A) 0.2/0.1
H Supply voltages (Un)
AC (with transformer) 380-400/220-230 (two voltages)
Frequency (Hz)
Permissible supply voltage variation (%)
50/60
+10 / -15
Ambient conditions
I Repeat accuracy with 0.85-1.1 Un (%)
Consumption (VA)
2
3
Storage temperature
Operating temperature
-10°C to +85°C
-5°C to +50°C
Input circuit test voltage (kV) 4 Relative humidity 95% (without condensation)
(between input, output circuit and Maximum operating altitude 2.000 m
X earth)
Voltage between probes (V ef.) 6 - 18
Degree of protection IP40; terminals IP20
Operating positions Any
and common
Max. consumption of probes (mA ef.) 0,18
Max.resistance between (kOhms) 200 Conformity to standards
probes (resistance of controlled liquid)
Switch ON response time (s) 1 VDE 0106 IEC/EN 60947-5-1 UNE 20119
Switch OFF response time (s) 1 Remark
The relays has one LED that lights up when the output contact is made.

F.26

32764_F14_F42_E.indd 26 12-07-2005 16:03:22


Series D
DINIL 03 Liquid level detector Filling control

relay for control of well


and tank
Functions
TANK

Electronic relays of 45 mm
DINIL-03 is a device to control levels of conducting liquids.
It can control the pump-in and pump-out of wells or tanks,
but not both simultaneously. The contact 11-14 makes if
the level is above or equal to the level fixed by probe Z2
and breaks if the level fails below level fixed by probe Z3.
Filling control: The contact 11-12 is used as permanent
control of the start of the pump.
Draining control: The contact 11-14 is used as permanent
control of the pump starting.

Remark: Common probe has to be always a little bit lower


level than probe detecting minimum low level, either well Draining control
or tank, and it can be connected to the container frame, if
it is metalic.

Sensivity will be adjusted by means of front potentiometer,


and its adjustement position depends on liquid resistivity.
The majority of timers could be adjusted at the middle of
he scale. A
If the relay does not connect when it has to, then adjust it
by turning up towards maximum (device allows up to 200
K ohms between max. or min. probes and common one).
B
If relay does not disconnect, adjust it by turning down
WELL
towards minimum (when resistance lower than 10 K ohms
between probes and common one can be adjusted at the C
minimum).

Technical characteristics D
DINIL-03
Nr. of changeover contacts 1
Output contacts:
Rated insulation AC (V) 400 E
voltage Ui DC (V) 250
Thermal current Ith (A) 6
Utilisation AC-15
Rated voltage Ue (V) 120/240 F
Rated current Ie (A) 2.5/1.3
Utilisation DC-13
Rated voltage Ue (V) 110/220
Rated current Ie
Supply voltages (Un)
(A) 0.2/0.1 Ambient conditions G
Storage temperature -10°C to +85°C
AC (with transformer) (V) 380-400,240,220-230,125,110,48,24
Frequency (Hz) Operating temperature -5°C to +50°C
50/60
Permissible supply voltage variation
(%)
+10 / -15 Relative humidity
Maximum operating altitude
95% (without condensation)
2.000 m
H
Repeat accuracy with 0.85 - 1.1 Un(%) 2 Degree of protection IP40; terminals IP20
Consumption (VA) 3 Operating positions Any
Input circuit test voltage
(between input, output circuit and
(kV) 4
I
earth)
Voltage between probes (V ef.) 6 - 18
Conformity to standards
VDE 0106 EN 50011 UNE 20119
and common
Max. consumption of probes (mA ef.) 0,18
EN 50001 DIN 46199 X
Max.resistance between (kohms) 200 EN 50005 IEC/EN 60947-5-1
probes (resistance of controlled liquid)
Switch ON response time (s) 1 Remark
Switch OFF response time (s) 1 The relay has one LED that lights up when the output contact is made.

F.27

32764_F14_F42_E.indd 27 12-07-2005 16:03:22


Series D
DINIL 03E Liquid level detector Filling control

relay for control of well


and tank (plug-in)
Functions
DINIL-03E is a device to control levels of conducting liquids.
TANK
It can control the pump-in and pump-out of wells or tanks,
but not both simultaneously. The contact 1-3 makes if the
level is above or equal to the level fixed by probe 9 and
breaks if the level fails below level fixed by probe 8.
Filling control: The contact 1-4 is used as permanent con-
Electronic relays

trol of the start of the pump.


Draining control: The contact 1-3 is used as permanent
control of the pump starting.

Remark: Common probe has to be always a little bit lower


Draining control
level than probe detecting minimum low level, either well
or tank, and it can be connected to the container frame, if
it is metalic.

Sensivity will be adjusted by means of front potentiometer,


and its adjustement position depends on liquid resistivity.
The majority of timers could be adjusted at the middle of
A he scale.

If the relay does not connect when it has to, then adjust it
B by turning up towards maximum (device allows up to 200
K ohms between max. or min. probes and common one).
If relay does not disconnect, adjust it by turning down
towards minimum (when resistance lower than 10 K ohms WELL
C between probes and common one can be adjusted at the
minimum).

D Control voltage: Single voltage:


terminals 2-10
Two voltages:
terminals 2-10 (220 VAC)
terminals 2-11 (380 VAC)

E Technical characteristics Ambient conditions


DINIL-03E Storage temperature -10°C to +85°C
Operating temperature -5°C to +50°C
Nr. of changeover contacts 1
Relative humidity 95% (without condensation)
F Output contacts:
Rated insulation AC (V) 400
Maximum operating altitude 2.000 m
Degree of protection IP40; terminals IP20
voltage Ui DC (V) 250
Operating positions Any
Thermal current Ith (A) 6

G Utilisation AC-15
Rated voltage Ue (V) 120/240
Rated current Ie
Utilisation DC-13
(A) 2.5/1.3 Conformity to standards
VDE 0106 IEC/EN 60947-5-1 UNE 20119
H Rated voltage Ue
Rated current Ie
(V)
(A)
110/220
0.2/0.1
Supply voltages (Un)
AC (with transformer) (V) 380/220 (two voltages) Remark
Frequency (Hz) 50/60 The relay has one LED that lights up when the output contact is made.
I Permissible supply voltage variation +10 / -15
Repeat accuracy with 0.85-1.1 Un (%) 2
Consumption (VA) 3
Input circuit test voltage (kV) 4
X (between input, output circuit and
earth)
Voltage between probes (V ef.) 6 - 18
and common
Max. consumption of probes (mA ef.) 0,18
Max.resistance between (kOhms) 200
probes (resistance of controlled liquid)
Switch ON response time (s) 1
Switch OFF response time (s) 1

F.28

32764_F14_F42_E.indd 28 12-07-2005 16:03:23


Series D
RDHT..., RDHA... RDH
Earth leakage relays
RDHT... Earth leakage relay with manual reset, with test
RDHA... Earth leakage relay with automatic reset, with test

Function Reset

Electronic relays of 45 mm
RDH, RDHT and RDHA are earth leakage detectors for
industrial networks with neutral connected to earth, used
with WKA (without test) and WKAT (with test) differential
transformers. Tripping is produced when leakage current
exceeds a threshold which is adjustable by means of a RDHT
front mounted potentiometer. Tripping ranges are shown in
the table below.
RDH and RDHT keep memory of tripping even in the
absence of voltage in A1 and A2 and resetting is obtained
from a push-button. RDHA is self resetting in the absence
Reset
of control voltage in A1 and A2 or when leakage dissap-
pears. RDHT and RDHA have in addition a test push-button

Remote
for control from cubicle door, and therefore those relays

test
should always be use with WKAT transformers with test
winding. All types have included a timer, with external
adjustement in RDHA and internal ajustement in RDH and
RDHT that allows to delay the trip to achieve trip selectivity.
RDHA
A
RDHT1-... Sensitivity Transformers Ø
RDHA1-...
... 1,2 0.2 - 1.2A WKAT-35 1.2A/2V 35
B
WKAT-70 1.2A/2V 70
WKAT-105 1.2A/2V 105
WKAT-140 1.2A/2V 140
WKAT-210 1.2A/2V 210
C

Remote
... 10 1 - 10A WKAT-35 10A/2V 35
WKAT-70 10A/2V 70

test
WKAT-105 10A/2V 105
WKAT-140 10A/2V 140
WKAT-210 10A/2V 210
D
Ambient conditions Technical characteristics
Storage temperature -10°C to+85°C RDH1-... RDHT1-... RDHA1-... E
Operating temperature 0°C to +50°C Nr. of changeover contacts 1
Relative humidity 95% (without condensation) Output contacts:
Altitude 2.000 m Rated insulation AC (V) 400

Degree of protection IP40; terminals IP20


voltage Ui
Thermal current Ith
DC (V)
(A)
250
6
F
Operating positions Any Utilisation AC-15
Rated voltage Ue (V) 120/240

Conformity to standards
Rated current Ie
Utilisation DC-13
(A) 2.5/1.3
G
VDE 0106 IEC/EN 60947-5-1 Rated voltage Ue (V) 110/220
EN 50001 UNE 20-119 Rated current Ie (A) 0.2/0.1
EN 50005
EN 50011
Supply voltages (Un)
AC (with transformer) (V) 380-400,240380-400,240380-400,240
H
DIN 46199 220-230,125220-230,125220-230,125
110, 48 110, 48, 24 110, 48, 24
DC/AC (direct)
Frequency
(V)
(Hz)
24 -
50/60
-
I
Permissible supply voltage variation +10 / -15
(%)
Repeat accuracy with 0.85-1.1 Un (%) 2
Consumption (VA) 3 X
Input circuit test voltage (kV) 4
(between input, output circuit and
earth)
Switch ON response time (s) 150-200 150-200 100
(can be delayed up to 5 sec)

F.29

32764_F14_F42_E.indd 29 12-07-2005 16:03:23


Series D
RDFF1... Integral protection relay
for three-phase lines
Function
Protection against:
a) Phase failure d) Low line voltage
b) Phase sequence e) High line voltage
c) Phase unbalance
Alarm
Relay operates by phase angle detection between voltages
and not by voltage levels and therefore will drive
Electronic relays

satisfactorly even with feedback from other motors.

Relays will connect only when all conditions are normal


(contact 15-18 closes) and disconnects on any fault
including supply, protecting network even with supply
failure. It will not connect if phase sequence is incorrect,
preventing motors starting in wrong direction.

Unbalance adjustement
Phase, unbalance, and therefore single phase is very
dangerous for the life of a motor. The graph belows shows
temperature rise in a three-phase motor with a phase
A unbalance (NEMA MG 1-1433 and 34). The per cent
Unbalance (%)
unbalance is obtained as follow:
Temperature increase (%)
Max. voltage deviation from ∆T - ∆T nom.
B % unbalance =
average voltage
average voltage
x 100 ∆T nom.
x 100

Tripping is adjustable between 2.5 and 10 %.


C Consequently protection is provided for motors working
Technical characteristics
closely adjusted to rated power, to others more generously
RDFF1-50 RDFF1-60
sized, and even power lines.
Nr. of changeover contacts 1
In any case adjustements should be made so that on fail-
D ure of one phase realy will disconnect.
Output contacts:
Rated insulation AC (V) 400
voltage Ui DC (V) 250
Voltage adjustement Thermal current Ith (A) 6

E Voltage tripping is adjustable form -5 to - 20 % and


+5 to +15 % maximum by which it is possible to adjust
Utilisation AC-15
Rated voltage Ue (V) 120/240
to values recommended by IEC 34.1 (1969) and IEC 158 Rated current Ie (A) 2.5/1.3
Utilisation DC-13
respectively. Tripping for these causes is delayed 1 second
Rated voltage Ue (V) 110/220
F approximately. Rated current Ie (A) 0,2/0,1
Supply voltages (Un)
Tripping indication AC (with transformer) (V) 500, 440, 380, 240, 220
Relays incorporate LED diode tripping indication. When Frequency (Hz) 50 60
G phase sequence is incorrect, both phase sequence and Permissible supply voltage variation +15 / -20
(%)
unbalance light up. When unbalance lights up only
Repeat accuracy with 0.85 - 1.1 Un(%) 2
indicates unbalance or single phasing with feedback. Consumption (VA) 3
H Input circuit test voltage (kV) 4

Ambient conditions (between input, output circuit and


earth)
Storage temperature -10°C to+85°C Unbalance tripping (adjustable) (%) 2.5 to 10
I Operating temperature
Relative humidity
-5°C to +50°C
95%(without condensation)
Low voltage tripping (adjustable) (%)
Overvoltage tripping (adjustable) (%)
5 to 20
5 to 15
Altitude 2.000 m Switch ON response time (ms) 200
Degree of protection IP40; terminals IP20 Reset hysteresis (%) 5 approx.

X Operating positions Any

Conformity to standards
VDE 0106 DIN 46199 IEC/EN 60947-5-1
EN 50001 UNE 20-119
EN 50005
EN 50011

F.30

32764_F14_F42_E.indd 30 12-07-2005 16:03:23


Series D
RPDF... Unbalance and phase
failure protection relay
for three-phase lines
Function

Electronic relays of 45 mm
The RPDF-electronic relay is intended for the protection
of lines or electronic motors against unbalance between
phases or failure of one or more phases. Detection of
unbalance or phase failure is done by measuring phase Alarm
change and not by voltage levels. This guarantees correct
working even when there are return paths due to motors
running which are connected to the mains networks to be
protected.The relay is made when all conditions are normal
(contact 11-14 closed); the contacts open in the event of a
failure. In this way, any failure, including that of the relay
supply, will cause disconnection and so avoid the supply
being left unprotected.

Setting unbalance
The unbalance in phases and, consequently, the failure of
one of these, is a limiting factor in the life of an electric
motor. The graph below shows the percentage
temperature increase in a three-phase motor as a
function of the degree of unbalance (see standards NEMA Unbalance (%)
A
MG 1-1433 and 34). The per cent unbalance is calculated Temperature increase (%)
as follows : ∆T - ∆T nom.
Max. voltage deviation from ∆T nom.
x 100
B
average voltage
% unbalance = x 100
average voltage

Technical characteristics C
The trip is adjustable between about 2.5% and 10%. RPDF RPDF
2-50 2-60
Consequently protection is provided for motors working
Nr. of changeover contacts 2 2
closely adjusted to rated power, to others more generously
sized, and even power lines. In any case, the adjustement
Output contacts: D
Rated insulation AC (V) 400
must be such that the loss of a phase produces the voltage Ui DC (V) 250
opening of the relay. Thermal current Ith (A) 6
Utilisation AC-15
Rated voltage Ue (V)
E
120/240
Rated current Ie (A) 2.5/1.3
Utilisation DC-13
Rated voltage Ue
Rated current Ie
(V)
(A)
110/220
0,2/0,1
F
Supply voltages (Un)
AC (with transformer) (V) 500, 440, 380, 240, 220
Frequency (Hz)
Permissible supply voltage variation
50
+10 / -20
60
G
(%)
Repeat accuracy (%) 2
Consumption
Input circuit test voltage
(VA)
(kV)
3
4 H
(between input, output circuit and
earth)
Unbalance tripping (adjustable) (%) 2.5 to 10
Switch ON response time (ms) 100 I
Reset hysteresis (%) 2

Ambient conditions
Storage temperature -10°C to+85°C Conformity to standards X
Operating temperature -5°C to +50°C VDE 0106 IEC/EN 60947-5-1
Relative humidity 95%(without condensation) EN 50001 UNE 20-119
Altitude 2.000 m EN 50005
Degree of protection IP40; terminals IP20 EN 50011
Operating positions Any DIN 46199

F.31

32764_F14_F42_E.indd 31 12-07-2005 16:03:24


Series D
RDMT1 Phase failure, unbalance
and three-phase
minimum voltage
protection relay

Function
The RDMT1 electronic relay is intended for the protection
of three phase lines or electronic motors against failure of
one or more phases, unbalance between phases or low Alarm
voltage.
Electronic relays

Detection of unbalance or phase failure is done by


measuring phase change and not by voltage levels, which
guarantees correct working even when there are return
paths due to motors running which are connected to the
mains networks to be protected. Low voltage
detector measures the mean value of the voltage in the
three phases.The relay is made when all conditions are
normal (contact 15-18 closed); the contacts open with a
delay of 3 seconds in the event of a failure lasting more
than this delay time. In this way, any failure, including that
of the relay supply, will cause disconnection so avoiding
A the supply being left unprotected.
Unbalance (%)
Setting unbalance
Temperature increase (%)
The unbalance in phases and, consequently, the failure of
B one of these, is a limiting factor in the life of an electric
∆T - ∆T nom.
∆T nom.
x 100
motor. The graph bottom right shows the percentage
temperature increase in a three-phase motor as a
C function of the degree of unbalance (see standards NEMA
MG 1-1433 and 34). The per cent unbalance is calculated
Technical characteristics
RDMT 1
as follows :
Nr. of changeover contacts 1
Max. voltage deviation from Output contacts:
D % unbalance =
average voltage
x 100 Rated insulation AC (V) 400
average voltage voltage Ui DC (V) 250
Thermal current Ith (A) 6
Utilisation AC-15
E Rated voltage Ue (V) 120/240
Rated current Ie (A) 2.5/1.2
The trip is adjustable between about 2.5% and 10%,
Utilisation DC-13
consequently protection is provided for motors ranging Rated voltage Ue (V) 110/220
F from closely adjusted to rated power, to the motors
generously sized, and even power lines. In any case, the
Rated current Ie (A) 0.2/0.1
Supply voltages (Un)
adjustement must be such that the loss of a phase AC (with transformer) (V) 380, 220 three-phase
produces the opening of the relay. Control supply voltage (A1-A2)
G AC
Frequency
(V)
(Hz)
220 single-phase
50
Setting undervoltage
Permissible supply voltage variation +15 / -20
The trip is adjustable between about 0% and -20% of the (%)
rated input voltage.
H Repeat accuracy
Consumption
(%)
(VA)
2
3
Tripping indication Input circuit test voltage (kV) 4
The relays incorporates a LED diode tripping indication. (between input, output circuit and

I When phase sequence is incorrect, both phase sequence


earth)
Unbalance (adjustable) (%) 2.5 to 10
and unbalance light up. When unbalance lights up only, Low voltage (adjustable) (ms) 0 a -20
Tripping hysteresis (%) 5 approx.
Switch ON response time (ms) 200
X Switch OFF response time (s) 3.5 ± 1.5

Ambient conditions
Storage temperature -10°C to+85°C
Conformity to standards
Operating temperature -5°C to +50°C VDE 0106 IEC/EN 60947-5-1
Relative humidity 95%(without condensation) EN 50001 UNE 20-119
Altitude 2.000 m EN 50005
Degree of protection IP40; terminals IP20 EN 50011
Operating positions Any DIN 46199

F.32

32764_F14_F42_E.indd 32 12-07-2005 16:03:24


Series D
RSFF... Phase sequence and RSF... Phase sequence relay
phase failure protection for three-phase lines
relay for three-phase lines Function
Function
The RSF1 is designed to detect phase sequence in three
The RSFF relay is designed to detect phase sequence errors phase power system. Three supplies U, V, W, take

Electronic relays of 45 mm
and/or phase failures in three phase lines. Three terminals voltage from each of the phases of the network. When
U, V, W are connected to each of the three phases of the phase sequence supplying relay is direct (Phase V with
mains. Controlling vectors of voltage between lines 120º lag in respect of U and phase W with 120º lag in
(amplitude and phase) is detected the direct sequence respect of V) the relays connects with supply (closes
(phase V with 120º in respect of U and phase W with 240º contact between 11-14) and if no it remains OFF. For
lag in respect and phase U) as well as balance of voltages correct operation, relay must have supplying each of the
and angles of phases, for detecting a phase failure even three phases.
with returns (motor working). A phase failure, when there is a return current (the motor
By means of an external potentiometer can be adjusted is rotating), is not detected by the relay and may lead to a
the network unbalance, level, between 2,5 % and 105 % to relay malfunction.
adapt the relays sensibility for phase failure function. This
unbalance is measured according to NEMA MG1-1433 and
34, and corresponds to a fall of simple tension of phase in
amplitude of 7.3 and 28%, respectively. The relay precives
AC
either increases or drops of voltage and angle, then it
detect the failures even in motors working as breaking
devices (loads going down in lifting devices). When relay
AC
is powered, it connects instantaneously (max. 200ms) if
the power system is correct. Once the switched on relay
A
is switch-on, it switches-off with 1 sec. delay in case of a
failure, to avoid false disconnections due to transient
unbalances. (Start of other motors, transformers, etc.). B
Technical characteristics
Nr. of changeover contacts
RSF1-50
1
RSF1-60
C
Output contacts:
Rated insulation AC (V) 400
voltage Ui
Thermal current Ith
DC (V)
(A)
250
6
D
Utilisation AC-15
Rated voltage Ue (V) 120/240
Rated current Ie
Utilisation DC-13
(A) 2.5/1.3
E
Rated voltage Ue (V) 110/220

Technical characteristics Rated current Ie


Supply voltages (Un)
(A) 0.2/0.1

RSFF1-50 RSFF1-60 AC (with transformer) (V) 380-400 / 220-230 (two voltages) F


Nr. of changeover contacts 1 Frequency (Hz) 50 60
Output contacts: Permissible supply voltage variation (%) +10 / -15
Rated insulation AC (V) 400 Repeat accuracy (%) 2
voltage Ui DC (V) 250 Consumption (VA) 3 G
Thermal current Ith (A) 6 Input circuit test voltage (kV) 4
Utilisation AC-15 (between input, output circuit and
Rated voltage Ue (V) 120/240 earth)
Rated current Ie (A) 2.5/1.3 Switch ON response time
Switch OFF response time
(ms)
(ms)
500
200
H
Utilisation DC-13
Rated voltage Ue (V) 110/220
Rated current Ie (A) 0.2/0.1 Ambient conditions
Supply voltages (Un)
AC (with transformer) (V) 440, 380-400, 220-230
Storage temperature -10°C to+85°C I
Operating temperature -5°C to +50°C
Frequency (Hz) 50 60
Relative humidity 95% (without condensation)
Permissible supply voltage variation (%) +15 / -20
Altitude 2.000 m
Repeat accuracy
Consumption
(%)
(VA)
2
3
Degree of protection IP40; terminals IP20 X
Operating positions Any
Input circuit test voltage (kV) 4
(between input, output circuit and earth)
Switch ON response time (ms) 200 Conformity to standards
Switch OFF response time (s) 1 VDE 0106 IEC/EN 60947-5-1 EN 50001 UNE 20-119
EN 50005 EN 50011 DIN 46199
max. voltage derivation from

% unbalance =
average voltage
x 100 Remark
average voltage The relay has one LED that lights when the output contact is made.

F.33

32764_F14_F42_E.indd 33 12-07-2005 16:03:24


Series D
RTMM2 Maximum and RMM2 Maximum and minimum
minimum voltage voltage relay for
protection relay for single-phase lines
three-phase lines
Function
Function
These voltage-sensitive relays with one or two changeover
The RTMM electronic relay is voltage sensitive and has one output contacts remain connected (contact between 11-14
or two changeover output contacts. The relay mantains or between 21-24 closed) when voltage is within tolerance
operated (contact between 11-14 or between 21-24 closed) limits, and opens when voltage surpasses these limits in
while the voltage is within the tolerance limits and opens plus or minus. Relays can be used to detect low or lover
Electronic relays

when these limits are surpassed in plus or minus. The relay voltage in balanced single or three-phase systems, and
can be used for low voltage or over-voltage detection in maximum and minimum tripping values are adjsutable by
three-phase lines. means of two frontal potentiometers. The limits for the trip
The trip value, for maximum and minimum voltage, are set are adjustable between 5 and 15% for maximum voltage
by means of two independent potentiometer mounted on and between 5 and 20% for minimum voltage.
the relay front cover. The limits for the trip are adjustable
between +5 and +15% for maximum voltage and between
-5 and -20% for minimum voltage.

Technical characteristics
C RMM 2
Nr. of changeover contacts 2
Technical characteristics Output contacts:

D RTMM2 Rated insulation


voltage Ui
AC
DC
(V) 400
(V) 250
Nr. of changeover contacts 2
Thermal current Ith (A) 6
Output contacts:
Utilisation AC-15
Rated insulation AC (V) 400
Rated voltage Ue (V) 120/240
E voltage Ui
Thermal current Ith
DC (V)
(A)
250
6 Rated current Ie (A) 2.5/1.3
Utilisation AC-15 Utilisation DC-13
Rated voltage Ue (V) 120/240 Rated voltage Ue (V) 110/220
Rated current Ie (A) 2.5/1.3 Rated current Ie (A) 0.2/0.1
F Utilisation DC-13 Supply voltages (Un)
Rated voltage Ue (V) 110/220 AC (with transformer) (V) 500,440,400,380,240,220,125,110,24
Rated current Ie (A) 0.2/0.1 DC (direct) (V) 24
Supply voltages (Un) Frequency (Hz) 50/60
G AC (with transformer)
Frequency
(V)
(Hz)
500,440,400,380,240,220,125,110
50/60
Permissible supply voltage variation +15 / -20
(%)
Permissible supply voltage variation (%) +20 / -20 Repeat accuracy (%) 2
Repeat accuracy (%) 2 Consumption (VA) 3
H Consumption
Input circuit test voltage
(VA)
(kV)
3
4
Input circuit test voltage
(between input, output circuit and
(kV) 4

(between input, output circuit and


earth)
earth)
Low voltage tripping (adjustable) (%) -5 to -20
Low voltage tripping (adjustable) (%) -5 to -20
I Over voltage tripping (adjustable) (%) +5 to +15
Over voltage tripping (adjustable) (%) +5 to +15
Reset hysteresis (%) 5 approx.
Switch ON response time (ms) 100
Reset hysteresis (%) 2 Switch ON response time (ms) 100

X Ambient conditions Conformity to standard Remark


The relay has one LED that lights when the output
Storage temperature -10°C to+85°C VDE 0106 IEC/EN 60947-5-1 contact is made.
Operating temperature -5°C to +50°C EN 50001 UNE 20-119
Relative humidity 95% EN 50005
(without condensation) EN 50011
Altitude 2.000 m DIN 46199
Degree of protection IP40; terminals IP20
Operating positions Any

F.34

32764_F14_F42_E.indd 34 12-07-2005 16:03:25


Series D
RDT2 Voltage detector relay RDTA2 Voltage detector relay
Function Function
The output contact in this voltage detector will connect The relay has the same characteristics as the RDT type
when controlled voltage between terminals B1-B2 exceeds (see E.52). Furthermore, it dispose of an internal galavanic
insulation between the terminals B1-B2 and A1-A2, for

Electronic relays of 45 mm
a certain adjustable threshold by means of the front
potentiometer and will disconnect with a voltage 10% DC applications only the voltage supply and voltage to be
below the setting value. controlled belong to the same line.
The relay requires voltages supply between A1-A2.
Controlled voltage can be either direct (DC) or alternat-
ing (AC). The output contact function can be set to NO by Voltage to
be controlled
means of an internal jumper (contact 11-14 is normally
closed and opens when control power supply or removal is
detected at A1-A2).
When the distance between the measurement point and
the relay is greater than 1m, in order to avoid any noise
problems, connection to the B1-B2 terminals should be
made by using a shielded cable, with its screen joined to
the B2 terminal and isolated at the other cable end or by
using a twisted-pair cable.

Technical characteristics
Voltage to RDTA2-...
be controlled
Nr. of changeover contacts
Output contacts:
2 A
Rated insulation AC (V) 400
voltage Ui DC (V) 250
Thermal current Ith
Utilisation AC-15
(A) 6
B
Rated voltage Ue (V) 120/240
Rated current Ie (A) 2.5/1.3
Utilisation DC-13
Rated voltage Ue (V) 110/220 C
Rated current Ie (A) 0.2/0.1

Technical characteristics Supply voltages (Un)


DC (direct) (V) 24
RDT2-... Permissible supply voltage variation +10 / -15 D
Nr. of changeover contacts 2 (%)
Output contacts: Consumption (VA) 3.7
Rated insulation AC (V) 400 Input circuit test voltage (kV) 2.5
voltage Ui DC (V) 250 (between input, output circuit and E
Thermal current Ith (A) 6 earth)
Utilisation AC-15 Reset hysteresis (%) 10
Rated voltage Ue (V) 120/240 Switch ON response time (ms) 100
Rated current Ie (A) 2.5/1.3 F
Utilisation DC-13
Rated voltage Ue (V) 110/220
Rated current Ie (A) 0.2/0.1
Supply voltages (Un)
AC (with transformer) (V) 380-400,240,220-230,125,110,48
G
DC/AC (1) (direct) (V) 24
Frequency (Hz) 50/60
Permissible supply voltage variation
(%)
+10 / -15
H
Consumption (VA) 3,7
Input circuit test voltage (kV) 2,5
(between input, output circuit and
earth) I
Reset hysteresis (%) 10
Switch ON response time (ms) 100

X
Ambient conditions Conformity to standards (1) Use only in applications with galvanic
insulation between terminlas B1-B2 and
Storage temperature -10°C to +85°C VDE 0106 IEC/EN 60947-5-1 A1-A2
Operating temperature -5°C to +50°C EN 50001 UNE 20-119 (i.e.: current transformers)
Relative humidity 95% EN 50005
(without condensation) Remark
EN 50011 The relay has a green LED which lights up when
Altitude 2.000 m the supply is between A1 and A2, and a red LED
DIN 46199
Degree of protection IP40; terminals IP20 when the contact is made (11-14).
Operating positions Any

F.35

32764_F14_F42_E.indd 35 12-07-2005 16:03:25


Series D
RDI2 Current detector relay RDIA2 Current detector relay
Function Function
The output contact in this current detector connects when The relay has the same characteristics as the RDI type
a current passing through terminals B1 and B2 exceeds a (see E.54). Furthermore, it dispose of an internal galvanic
certain adjustable threhold by means the front insulation between the terminals B1-B2 and A1-A2, for DC
potentiometer and disconnects with a current 10% below applications only when the voltage supply and current to
current value. If can detect either alternating or direct be controlled belong to the same line.
current. Relay requires rated supply voltage between A1
and A2. The output contact function can be set to NO (the
11-14 contact closes when the supply voltage is detected)
or to NC (the 11-14 contact is normally closed and opens
Electronic relays

when control power supply is detected or removed from


A1-A2) by means of an internal jumper. The 0.2 V ver-
sion is designed to be used with an external shunt and in
case that the distance between the shunt and the relay
is greater than 1 m, a connection to the B1-B2 terminals
should be made by using a shielded cable, with its screen
joined to the B2 terminal and isolated on the shunt side or
by using a twisted-pair cable.

Technical characteristics
RDIA2-...

A Nr. of changeover contacts


Output contacts:
2

Rated insulation AC (V) 400


voltage Ui DC (V) 250
B Thermal current Ith
Utilisation AC-15
(A) 6

Rated voltage Ue (V) 120/240


Rated current Ie (A) 2.5/1.3

C Utilisation DC-13
Rated voltage Ue (V) 110/220
Rated current Ie (A) 0.2/0.1
Technical characteristics Supply voltages (Un)

D RDI2-...
DC (direct)
Permissible supply voltage variation
(V) 24
+10 / -15
Nr. of changeover contacts 2 (%)
Output contacts:
Repeat accuracy with 0.85 - 1.1 Un(%) 2
Rated insulation AC (V) 400 Consumption (VA) 3
E voltage Ui
Thermal current Ith
DC (V)
(A)
250
6
Input circuit test voltage (kV) 4
(between input, output circuit and
Utilisation AC-15
earth)
Rated voltage Ue (V) 120/240 Switch ON response time (ms) 100
F Rated current Ie
Utilisation DC-13
(A) 2.5/1.3 Switch OFF response time (ms) 100
Reset time between 2 cycles (2) (ms) 100
Rated voltage Ue (V) 110/220
Rated current Ie (A) 0,2/0,1

G Supply voltages (Un)


AC (with transformer) (V) 380-400,240,220-230,125,110,48
DC/AC (1) (direct) (V) 24
Frequency (Hz) 50/60
Permissible supply voltage variation (%) +10 / -15
H Repeat accuracy with 0.85-1.1 Un (%) 2
Consumption (VA) 3
Input circuit test voltage (kV) 4
(between input, output circuit and earth)
I Switch ON response time (ms) 100
Switch OFF response time (ms) 100
Reset time between 2 cycles (2) (ms) 100

X (1) Use only in applications with galvanic insula-


Ambient conditions Conformity to standards tion between terminals B1-B2 and A1-A2
(i.e.: current transformers)
Storage temperature -10°C to +85°C VDE 0106 IEC/EN 60947-5-1 (2) Reset time: Time that must go by from the re-
Operating temperature -5°C to +50°C EN 50001 UNE 20-119 lay ends an operation until it is able to initiate
Relative humidity 95% the next one without error.
EN 50005
(without condensation) EN 50011 Remark
Altitude 2.000 m
DIN 46199 The relay has a green LED which lights up when
Degree of protection IP40; terminals IP20 the supply is between A1 and A2, and a red LED
Operating positions Any when the contact is made (11-14).

F.36

32764_F14_F42_E.indd 36 12-07-2005 16:03:26


Series D
RDIT2 Current detector relay RDITA2 Current detctor relay
with delay (0.5-15 seconds) with delay
Function Function
This relay is similar to the RDI except that it will connect This relay has the same function as the RDIT type(see E.56).
with a certain adjustable delay of 0.5 to 15 secs. If current Furthermore, it dispose of an internal galvanic insulation

Electronic relays of 45 mm
falls below threshold before timeout, relay will reset between the terminals B1-B2 and A1-A2, for DC applica-
inmediately to recount delay from zero. For higher currents, tions only when the voltage supply and current to be
current transformers or shunts of suitable ratios can be controlled belong to the same line.
used. The realy requires voltages supply between A1-A2.
Controlled voltage can be either direct (DC) or alternating
(AC). The output contact function can be set to NO (the
15-18 contact closes when the delay time has elapsed)
or to NC (the 15-18 contact is normally closed and opens
when the delay time has elapsed or when the control
power supply is removed from A1-A2) by means of an
internal jumper. The 0.2 V version has been designed to be
used with an external shunt and if the distance between
the shunt and the relay is greater than 1 m, a connection
to the B1-B2 terminals should be made by using a shielded
cable, with its screen joined to the B2 terminal and isolated
on the shunt side or by using a twisted-pair cable.
Technical characteristics
RDITA2-...
Nr. of changeover contacts 2
A
Output contacts:
Rated insulation AC (V) 400
voltage Ui DC (V) 250
Thermal current Ith (A) 6 B
Utilisation AC-15
Rated voltage Ue (V) 120/240
Rated current Ie (A) 2.5/1.3
Utilisation DC-13 C
Rated voltage Ue (V) 110/220
Rated current Ie (A) 0.2/0.1
Supply voltages (Un)

Technical characteristics DC (direct) (V) 24 D


Permissible supply voltage variation +10 / -15
RDIT2-... (%)
Nr. of changeover contacts 2 Repeat accuracy with 0.85-1.1 Un (%) 2
Output contacts:
Rated insulation AC (V) 400
Consumption
Input circuit test voltage
(VA)
(kV)
3
4
E
voltage Ui DC (V) 250 (between input, output circuit and
Thermal current Ith (A) 6 earth)
Utilisation AC-15
Rated voltage Ue (V) 120/240
Switch OFF response time
Reset time between 2 cycles
(s)
(%)
0.5 to 15
100
F
Rated current Ie (A) 2.5/1.3
Utilisation DC-13
Rated voltage Ue
Rated current Ie
(V)
(A)
110/220
0.2/0.1
G
Supply voltages (Un)
AC (with transformer) (V) 380-400,240,220-230,125,110,48
DC / AC (1) (direct) (V) 24
Frequency (Hz) 50/60 H
Permissible supply voltage variation (%) +10 / -15
Repeat accuracy with 0.8 -1.1 Un (%) 2
Consumption (VA) 3
Input circuit test voltage (kV) 4 I
(between input, output circuit and earth)
Switch OFF response time (s) 0.5 to 15
Reset time between 2 cycles(2) (ms) 100
(1) Use only in applications with galvanic insula-
tion between terminlas B1-B2 and A1-A2 X
Ambient conditions Conformity to standards (i.e.: current transformers)
Storage temperature -10°C to +85°C VDE 0106 IEC/EN 60947-5-1 (2) Reset time: Time that must go by from the re-
Operating temperature -5°C to +50°C EN 50001 UNE 20-119 lay ends an operation until it is able to initiate
Relative humidity 95% EN 50005 the next one without error.
(without condensation) EN 50011 Remark
Altitude 2.000 m
DIN 46199 The relay has a yelow LED which lights up when
Degree of protection IP40; terminals IP20 the supply is between A1 and A2, and a red LED
Operating positions Any when the contact is made15-18.

F.37

32764_F14_F42_E.indd 37 12-07-2005 16:03:26


Series D
RS01N Thermistor relay RSR1... Adjustable thermistor
Function relay
Function
This thermal probe relay is sensitive to resistance of several
thermal probes (thermistors, PTC) connected to P1 and P2 This relay has been designed for temperature control by
and detect overheating in motor windings transformers, type PT100 temperature probes. In normal conditions it is
etc. where these PTC are connected. ON (contact 11-14 closed), and OFF when a temperature
The relays disconnects when probe resistance exceeds exceeding the given temperature is detected; if probe wires
2500 ohms and cannot reset until resistance is lower than are cut or relay remains without supply. By this means
1500 ohms. Control voltage should be applied to A1 and tripping is ensured in the even the system is without
A2, the absence of this will cause relay to trip and prevent protection.
any possibility remaining without protection. In this case The three wire condition system shown in the wire diagram
Electronic relays

resetting is automatic, but if the relay trips through probe allows wire resistance compensation.
heating, resetting may be automatic, hand or remote
(distance NC contact).
RS01N detect those cases of probe cables short-circuited
(resistance lower than 20 Ohms) or probe cables cut
(resistance higher than 2.5k Ohms). The resistance at 25 °C
of the probe circuit must be within 40 to 600 ohms range.
Thermal probe
PT-100
Manual
reset

A Automatic
reset

Technical characteristics
B Remote
reset RSR1-...
Nr. of changeover contacts 1
Output contacts:

C Rated insulation
voltage Ui
AC
DC
(V)
(V)
400
250
Technical characteristics Thermal current Ith (A) 6
Utilisation AC-15
RS01N
D Nr. of changeover contacts 1
Rated voltage Ue
Rated current Ie
(V)
(A)
120/240
2.5/1.3
Output contacts: Utilisation DC-13
Rated insulation AC (V) 400 Rated voltage Ue (V) 110/220
voltage Ui DC (V) 250 Rated current Ie (A) 0.2/0.1
E Thermal current Ith (A) 6 Supply voltages (Un)
Utilisation AC-15 AC (with transformer) (V) 380-400,240,220-230,125,110,48
Rated voltage Ue (V) 120/240 DC / AC (1) (direct) (V) 24
Rated current Ie (A) 2.5/1.3 Frequency (Hz) 50/60
F Utilisation DC-13 Permissible supply voltage variation +10 / -15
Rated voltage Ue (V) 110/220 (%)
Rated current Ie (A) 0.2/0.1 Repeat accuracy with 0.85 - 1.1 Un(%) 2
Supply voltages (Un) Consumption (VA) 3
G AC (with transformer)
DC / AC (1) (direct)
(V)
(V)
380-400,240,220-230,125,110,48
24
Input circuit test voltage (kV) 4
(between input, output circuit and
Frequency (Hz) 50/60 earth)
Permissible supply voltage variation (%) +10 / -15 Switch OFF response time (ms) 100
H Repeat accuracy with 0.85-1.1 Un (%)
Consumption (VA)
2
3
Hysteresis (%) 10

Input circuit test voltage (kV) 4


(between input, output circuit and earth)

I Switch OFF response time


Hysteresis (kOhms)
(s) 100
1
Probe resistance min. (at 25°C) (Ohms) 40
Probe resistancemax. (at 25°C) (Ohms) 600
Max. voltage in terminals P1-P2 (R=2.5kV)(V) < 1,6
X
Ambient conditions Conformity to standards (1) There is an special version available, with
provide disconnection at 750 ohms (standard
Storage temperature -10°C to +85°C VDE 0106 IEC/EN 60947-5-1 BS 4999) instead of 1,5 kOhms (standard DIN
Operating temperature -5°C to +50°C EN 50001 IEC 34-11-2 (RS01N) VDE 0660-303, IEC 34-11-2)
Relative humidity 95% EN 50005 UNE 20-119
(without condensation) Remark
EN 50011
Altitude 2.000 m The relay has one LED that lights when the output
DIN VDE 0660-303 (RS01N) contact is made.
Degree of protection IP40; terminals IP20
DIN 46199 (RSR)
Operating positions Any

F.38

32764_F14_F42_E.indd 38 12-07-2005 16:03:26


Series D
RCF 1 Frequency control relay MRI2... Instant auxiliary relay
Function Function
This frequency control relay is sensitive to frequency of the Electronic relay with two contacts, that connects
signal applied to terminals B1 and B2 and output contact instantaneously when supply is applied to terminals A1
and A2.

Electronic relays of 45 mm
connects when frequency fails below a threshold adjsutable
by the front potentiometer. Supply voltage should also be This relay can be connected via a proximity detector
applied to relay between terminals A1 and A2 to produce whose leakage current is less than 4mA.
connection. Possibility of three settings ranges (by cross-
connection): 5-15Hz, 15-45Hz, 45-135Hz.
Switching is independent of input signal level at B1-B2,
whitin a wide range of values, and response is not changed
by the input signal wave form ( sinusoidal, square,
triangular, etc).
Relay is suitable for suppression of rotor resistance in
slipring asynchronous motors starters, speed reversal
detector in motor wound motors and frequency control in
generating sets.

Technical characteristics
MRI 2 A
Nr. of changeover contacts 2
Output contacts:
Rated insulation
voltage Ui
AC
DC
(V)
(V)
400
250 B
Thermal current Ith (A) 6
Utilisation AC-15
Rated voltage Ue (V) 120/240
Rated current Ie (A) 2.5/1.3 C
Technical characteristics Utilisation DC-13
Rated voltage Ue (V) 110/220
RCF-1
Rated current Ie (A) 0.2/0.1
Nr. of changeover contacts
Output contacts:
1 Supply voltages (Un) D
AC (with transformer) (V) 110-125, 220-240
Rated insulation AC (V) 400 DC/AC (direct) (V) 24, 48
voltage Ui DC (V) 250 Frequency (Hz) 50/60
Thermal current Ith
Utilisation AC-15
(A) 6 Permissible supply voltage variation
(%)
+10 / -15 E
Rated voltage Ue (V) 120/240 Consumption (mA) 60
Rated current Ie (A) 2.5/1.3 Input circuit test voltage (kV) 4
Utilisation DC-13
Rated voltage Ue (V) 110/220
(between input, output circuit and
earth)
F
Rated current Ie (A) 0.2/0.1 Switch ON response time (ms) 50
Supply voltages (Un) Switch OFF response time (ms) 50
AC (with transformer) (V) 380-400,240,220230,125,110,48,24
Frequency (Hz) 50/60 G
Permissible supply voltage variation(%) +10 / -15
Voltage between B1-B2 terminals(V c.a.) 15 to 500
Repeat accuracy with 0.85-1.1 Un (%) 2
Consumption (VA) 3 H
Input circuit test voltage (kV) 4
(between input, output circuit and
earth)
Switch ON response time
Switch OFF response time
(ms)
(ms)
100
800
I
Reset hysteresis (%) 1.5 approx.

Ambient conditions Conformity to standards Remark


The relay has one LED that lights when the output
X
Storage temperature -10°C to +85°C VDE 0106 EN 50042 (MRI) contact is closed.
Operating temperature -5°C to +50°C VDE 0110 (MRI) DIN 46199 (RCF)
Relative humidity 95% EN 50001 (RCF) IEC/EN 60947-5-1
(without condensation) EN 50002 (MRI) UNE 20-119 (RCF)
Altitude 2.000 m EN 50005 UL 94 (MRI)
Degree of protection IP40; terminals IP20 EN 50011 UL 508 (MRI)
Operating positions Any

F.39

32764_F14_F42_E.indd 39 12-07-2005 16:03:27


Series DM, NMV, D
Dimensional drawings
Series DM and NMV
RCRT 6 - 60
Electronic relays

Series D
RDFF

B
DINIL-02E, -03E

A
E RET, RTC, RTCI, RRD, RTD, 4
RIC, RCR, DINIL-02, DINIL-03,
RTMM, RDI, RDIA RSR, RCF
RS01N 8

F H6SZ13EFT

I
A
RDMT, RPDF, RMM, RDT,RDTA, 4
RDIT, RDITA
X RDH, RDHT, RDHA 12

F.40

32764_F14_F42_E.indd 40 12-07-2005 16:03:54


Series DM, NMV, D

Differential transformers Remote potentiometer

Dimensions
TYPE A B C D E F
WKA-35 35 75 99 42 92 33.5
WKA-70 70 98 132 60.5 115 33.5
WKA-105 105 141 175 82 158 33.5
WKA-140 140 183 218 103.5 200 33.5
WKA-210 210 270 309 150 290 43
WKAT-35 35 75 99 42 92 33.5
WKAT-70 70 98 132 60.5 115 33.5
WKAT-105 105 141 175 82 158 33.5
WKAT-140 140 183 218 103.5 200 33.5
WKAT-210 210 270 309 150 290 43
A

F.41

32764_F14_F42_E.indd 41 12-07-2005 16:03:59


Everything is
Limit switches
Series IS and IM - Metal and thermoplastic EN 50041
G.3 Order codes
G.10 Technical data
G.11 Dimensions

Series IUG and IUC - Thermoplastic EN 50047


G.5 Order codes
G.10 Technical data
G.13 Dimensions

Series IZ - Thermoplastic, miniature design


G.6 Order codes
G.10 Technical data
G.15 Dimensions
Plug-in relays and Auxiliary contactors A
Series 114FCT - Three pole limit switches
G.9 Order codes Motor protection devices B
G.15 Dimensions
Contactors and Thermal overload relays C
Series 115 - Pressure switches
G.18 Order codes Motorstarters D
G.20 Technical data
G.21 Dimensions Control and signalling units E

Safety switches Electronic relays F


G.23 In plastic body
Limit switches G

G.24 In metal body


Speed drive units H
G.24 In plastic body
G.25 For elevators and escalotors
Main switches I
G.25 For monitoring of hinges, flaps and doors
G.28 Dimensions
Numerical index X

under control
G.27

G.29
Pull rope switiches

Order codes

Dimensions

G.1
Series IS and IM
Metal and thermoplastic limit switches.
Positive opening. Conforming to EN 50041
• Fixing center lines and operation points in accordance with
EN 50041
• NC contacts with positive opening to IEC/EN 60947-5-1
• IP65 protection
• Terminal numbering according to IEC/EN 50013
• Cable entry M20 x 1.5
• Safety switches according to cat. 1 of IEC/EN 60947-5-1
(depends on actuating system)
• CSA and UL certified
Limit switches

Standards Specifications
A IEC/EN 60947-5-1
Degree of protection
Ambient conditions
IP 65

IEC/EN 60204-1 Storage temperature °C -40 to +80


Operating temperature °C -25 to +80

B Resistance to shocks (10 ms)


Resistance to vibrations (10-55 Hz)
g
g
30
25
Mechanical endurance ops. 10 x 106
Approvals Cable entry M20 x 1.5
Fixing screws 4 x M5
C

D
Mounted versions Switch function on request
Contact type Switch function Switch contacts Voltage Current
Series IS...
E Slow make & break NC 2NC
Ui
400V
Ithe
5A
• Double-insulated
Slow make & break Changover 1NC/1NO 400V 10A
bodies, in
(overlapping)
thermoplastic
F material, according
Slow make & break
(overlapping)
Changeover 2NC/1NO 400V 5A

to UL-94 VO
• Clip-fixing and
G opening of terminal
acces cover, no
screws.

H Series IM...
• Metal bodies
constructed from
injected aluminium.
I • Cover fastening by
screws.

Order codes ! pg. G.3


Technical data ! pg. G.10
Dimensions ! pg. G.11

G.2

32764_G01_G09_E.indd 2 12-07-2005 16:50:54


Series IS and IM
Limit switches according to EN 50041
Mounting position of the Slow break Snap action
head (3)

II III

Heads Head Form to Cat.no Ref. no. Cat.no Ref. no. Pack
Standard position position EN 50041

Plunger III B ISGA-B211 130000 ISGA-B411 130018 5


III B IMGA-B211 130001 IMGA-B411 130019 5

Side plunger III F IMGF-B411 130042 5

Order codes
Roller plunger III C ISGR-B211 130002 ISGR-B411 130020 5
III C IMGR-B211 130003 IMGR-B411 130021 5

Side vertical III G IMGG-B411 130043 5


roller plunger

Roller level III (1) ISGH-B211 130004 ISGH-B411 130022 5


III (1) IMGH-B211 130005 IMGH-B411 130023 5
A

Angular roller III (1) ISGJ-B211 130006 ISGJ-B411 130024 5


level III (1) IMGJ-B211 130007 IMGJ-B411 130025 5 B

Retractable returning
roller lever
III
III
(1)
(1)
ISGE-B211
IMGE-B211
130008
130009
ISGE-B411
IMGE-B411
130026
130027
5
5
C

Roller crank III


III
A
A
ISGL-B211
IMGL-B211
130010
130011
ISGL-B411 130028
IMGL-B411(4) 130029
5
5
D

Adjustable roller II (1) ISGT-B111 130012 ISGT-B311 130030 5 E


crank (2) II (1) IMGT-B111 130013 IMGT-B311 130031 5

F
Quadrant III (1) ISGV-B411 130032 5
III (1) IMGV-B411 130033 5

G
Rod lever (2) II D ISGP-B111 130014 ISGP-B311 130034 5
II D IMGP-B111 130015 IMGP-B311 130035 5

H
Cross rod II (1) ISGC-B411 130036 5
II (1) IMGC-B411 130037 5
I
Spring rod lever III (1) ISGQ-B111 130016 ISGQ-B311 130038 5
(2) III (1) IMGQ-B111 130017 IMGQ-B311 130039 5
X

Omnidirectional III (1) ISGM-B311 130040 5


spring rod (2) III (1) IMGM-B311 130041 5

Positive break (1) Fixing center lines and operation points in accordance with EN 50041.
(2) Heads for these limit switches have no positive opening, as they are adjustable or flexible.
(3) Supplied in standard mounting position. Positions II and III must be set by user.
(4) Available with metal roller lever: IMGL-B411M (130107). G.3

32764_G01_G09_E.indd 3 12-07-2005 16:50:55


Series IUG and IUC
Thermoplastic limit switches.
Positive opening conforming to EN 50047

• Fixing center and operation points (IUG...) in accordance with EN 50047


• NC contacts with positive opening according to IEC/EN 60947-5-1
• IP65 protection
• Terminal numbering according to EN 50013
• Thermoplastic material according to UL-94 V0
• One bottom cable entry M20x1,5 on Series IUG...
Two side cable entries for M16x1,5 on Series IUC.
• Two fixing possibilities for series IUGA...
• Clip fixing and opening of terminals access cover, no screws.
Limit switches

• CSA and UL certified

Standards Specifications
A IEC/EN 60947-5-1
Degree of protection
Ambient conditions
IP 65

IEC/EN 60204-1 Storage temperature °C -40 to +80


Operating temperature °C -25 to +80

B Resistance to shocks (10 ms)


Resistance to vibrations (10-55 Hz)
g
g
30
25
Mechanical endurance ops. 10 x 106
Approvals Cable entry IUG... 1 x (M20x1.5)

C Fixing screws
IUC... 2 x (M16x1.5)
2 of M5

D
Mounted versions
Switch function
Series IUG...
E Contact type Switch function Switch contacts
IUG Slow make & break Changeover 1NC/1NO
Voltage
250V
Current
10A
Snap action Changeover 1NC/1NO 250V 10A
IUC Slow make & break Changeover 1NC/1NO 400V 10A

F Snap action Changeover 1NC/1NO 400V 10A

G
Switch function on request
Series IUC...
Contact type Switch function Switch contacts Voltage Current
H Slow make & break
Slow make & break
NC
NO
2NC
2NO
250V
250V
5A
5A

Order codes ! pg. G.5


Technical data ! pg. G.10
Dimensions ! pg. G.13

G.4

32764_G01_G09_E.indd 4 12-07-2005 16:50:56


Series IUG and IUC
Limit switches according to EN 50047
Mounting position of the Slow break Snap action
head (3)

II III

Heads Head Form to Cat. Ref. no. Cat. Ref. no. Pack
Standard position position EN 50047 no. no.

Plunger III B IUGA-B211 130060 IUGA-B411 130082 5


III (1) IUCA-B211 130061 IUCA-B411 130083 5

Low roller III C IUGU-B211 130062 IUGU-B411 130084 5


plunger III (1) IUCU-B211 130063 IUCU-B411 130085 5

Order codes
Low roller III IUGR-B211 130064 IUGR-B411 130086 5
plunger III IUCR-B211 130065 IUCR-B411 130087 5

Roller lever III E IUGH-B211 130066 IUGH-B411 130088 5


III (1) IUCH-B211 130067 IUCH-B411 130089 5

Adjustable roller III IUGI-B211 130068 IUGI-B411 130090 5 A


lever III IUCI-B211 130069 IUCI-B411 130091 5

B
Angular roller III IUGK-B211 130070 IUGK-B411 130092 5
lever

C
Adjustable angular III IUGJ-B211 130071 IUGJ-B411 130093 5
roller lever

D
Retractable returning III IUGE-B211 130072 IUGE-B411 130094 5
roller lever III IUCE-B211 130073 IUCE-B411 130095 5
E

Roller crank III A IUGL-B211 130074 IUGL-B411 130096 5


(28mm between centres) III (1) IUCL-B211 130075 IUCL-B411 130097 5 F

Adjustable roller
crank (2)
II
II
IUGT-B111
IUCT-B111
130076
130077
IUGT-B311
IUCT-B311
130098
130099
5
5
G

Rod lever (2) II IUGP-B111 130078 IUGP-B311 130100 5 H


II IUCP-B111 130079 IUCP-B311 130101 5

I
Spring rod III IUGQ-B111 130080 IUGQ-B311 130102 5
lever (2) III IUCQ-B111 130081 IUCQ-B311 130103 5

X
Omnidirectional III IUGM-B311 130104 5
spring rod(2) IUCM-B311 130105 5

(1) Fixing centre lines and operating points according to EN 50047.


(2) Heads for these limit switches have no positive opening.
(3) Supplied in standard position. Positions II and III must be set by user.
Positive break

G.5

32764_G01_G09_E.indd 5 12-07-2005 16:50:56


Series IZ
Miniature thermoplastic limit switches
• The small sizes makes these ideal for use in reduced spaces
• With slow break, NC contacts with positive opening according
to IEC/EN 60947-5-1
• 2 mm contact opening of slow-action system according to EN 81-1 for lift
application
• IP30 protection
• Terminal numbering according to EN 50013
• Thermoplastic material in accordance with UL-94 V0
• Clip fixing and opening of the contact access cover, no screws
• Two fixing possibilities: 2 x M3 from the top
2 x M4 for mounting from the front
Limit switches

Approvals Switch function


A Contact type
Slow make & break
Switch function Switch contacts
Changeover 1NC/1NO
Voltage
250V
Current
10A
Snap action Changeover 1NC/1NO 250V 10A

B Mounted versions

D
Order codes ! pg. G.6
E Technical data ! pg. G.10
Dimensions ! pg. G.15

Miniature limit switches


F Slow break Snap - action

G
Heads Cat. no. Ref. no. Cat. no. Ref. no. Pack

H Plunger IZMA-B211 130140 IZMA-B311 130144 10

I Push-button (adjustable) IZMS-B211 130141 IZMS-B311 130145 10

X Roller plunger IZMR-B211 130142 IZMR-B311 130146 10

Roller lever IZMH-B211 130143 IZMH-B311 130147 10

G.6

32764_G01_G09_E.indd 6 12-07-2005 16:50:58


Series IZ
Notes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Order codes
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

G.7

32764_G01_G09_E.indd 7 12-07-2005 16:50:58


Series 114FCT

Three pole limit switches


• Switch-box, cover and operation plunger by thermoplastic resin.
• Silver contacts.
• Lockable cover with one screw only.
• Two basic versions:
Without seal Protection IP40 according to IEC 529
With seal Protection IP65 according to IEC 529
(Types NEMA 1, 12 and 13 according to UL,
ENCL. 3 according to CSA)
• Four electrical functions for both versions.
• Slow operation contacts, double-break and positive break of
NC contacts.
• With screws, retractable and captive clamp type. Protection against
Limit switches

accidental contact with live parts, degree of protection IP2x according


to IEC 529.

Standards Specifications
A IEC/EN 60947-5-1
Mechanical performances
Climatic protections
VDE 0660 Temperate climate (DIN 50014) 23 / 50
Wet climate (DIN 50015) 23 / 83
BSI 4794
B NFC 63140
Hot wet climate (DIN 50015)
Variable wet climate (DIN 50016)
40 / 92
FW 24
Temperature ranges
Operation -25ºC to +70ºC

C Approvals Storage
Vibrations resistance
-40ºC to +70ºC
10g
(according to IEC 68-2-6) with frequency range from 1 to 100Hz
Mechanical endurance 10 x 106 operations
Operation speed
D Min.
Max.
0.25 m/sec.
1 m/sec.
Actuating force Electrical performances
Rated insulation voltage (Ui) EN 60947.1 690V
E Minimum actuating force
114FCT03, ...03T 7.5N
Impulse withstand voltage (Uimp) EN 60947.1
Insulation class according to VDE 0660
4kV
Group C
114FCT12, ...12T 10N Electrical shocks protection IEC 536 Class II (double insulation)
114FCT21, ...21T 12N Short-circuit protection according to IEC 269.1 and 269.3 10A

F 114FCT30, ...30T
Positive opening force
13N Rated thermal current: Ith
Performances according to IEC 947.5.1
10A

114FCT03, ...03T 8.5N Cat. AC15 Voltage Ue (V) 24 48 60 110 220 380 500 600
114FCT12, ...12T 8.5N Current Ie (A) 10 10 10 6 3 2 1.5 1.2
114FCT21, ...21T 8.5N
G 114FCT30, ...30T -
Cat. DC13 Voltage Ue
Current Ie
(V)
(A)
24
2.5
48
1.4
60
1
110
0.55
220
0.27
300
0.2
Maximum force Performances according to UL and CSA AC / Heavy duty (A600)
114FCT03, ...03T 12N DC / Standard duty (Q300)
114FCT12, ...12T 13.5N Terminals
H 114FCT21, ...21T 15.5N Capacity min. 22 AWG (0.32mm2)
114FCT30, ...30T 17N Rigid and/or flexible conductors max. 12 AWG (3.3mm2)
Cable entry 1 x PG11

X Order codes ! pg. G.9


Dimensions ! pg. G.15

G.8

32764_G01_G09_E.indd 8 12-07-2005 16:50:59


Series 114FCT
Three pole limit switches
Contacts Diagrams Protection Cat. no. Ref. no. Pack.

IP40 114FCT03 130320 1


IP65 114FCT03T 130321 1

Positive opening travel

IP40 114FCT12 200909 1


IP65 114FCT12T 212693 1

Order codes
Positive opening travel

IP40 114FCT21 200910 1


IP65 114FCT21T 200911 1

Positive opening travel

IP40
IP65
114FCT30
114FCT30T
200912
215422
1
1
A

Three pole insulated jumper 105PT 132234 1


C

G.9

32764_G01_G09_E.indd 9 12-07-2005 16:50:59


Series IS, IM, IUG, IUC, IZ, 114FCT
Technical data

Limit switches
ISG..-B111 ISG..-B311 IUG..-B111 IUG..-B311 IZM..-B211 IZM..-B311
IMG..-B111 IMG..-B311 IUC..-B111 IUC..-B311
ISG..-B211 ISG..-B411 IUG..-B211 IUG..-B411
IMG..-B211 IMG..-B411 IUC..-B211 IUC..-B411
Type of break Slow break Snap action Slow break Snap action Slow break Snap action
Number of contacts 2 2 2 2 2 2
Function 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC
Polarity Same Same Same Same Same Same
Rated thermal current (Ithe) (A) 10 10 10 10 10 10
Auxiliary contacts
Rated insulation voltage (Ui)V 400 400 500 500 380 250
Limit switches

Protection against electrical shocks Class II (SG) Class II (SG) Class II Class II - -
CLASS I (MG) CLASS I (MG)
Protection against electrical shocks (fuse) (A) 10 2 10 2 6 6
Rated current (DIN EN60947-5-1)
A300 AC-15 12/24V (A) - - - - - -
48/60V (A) - - - - - -
(110V) 120V (A) 6 6 6 6 6 6
127V (A) - - - - - -
(220V) 240V (A) 3 3 3 3 3 3
380V (A) - - - - - -
Q300 DC-13 24V (A) - - - - - -
48V (A) - - - - - -
A (110V) 125V (A) 0.55 0.55 - - 0.55 0.55
(220V) 250V (A) 0.27 0.27 - - 0.27 0.27
300V (A) - - - - - -
Operating rate ops./h 6000 6000 6000 6000 6000 6000
B Switching time (ms) - 10 - 10 - 10
Repetition assurance (mm) ± 0.1 ± 0.1 ± 0.1 ± 0.1 ± 0.1 ± 0.1
Clamping capacity (mm2) 0.5 - 1.5 1.5 1.5 1.5 1.5 1.5
Terminal screw M3.5 M3.5 M3.5 M3.5 M3.5 M3.5
C Protection IP65 IP65 IP65 IP65 IP30 IP30

G.10
Series IS and IM
Dimensional drawings

Contact block Series IS Contact block Series IM


Common for all limit switches Series IS Common for all limit switches Series IM...

Dimensions
Operating heads
ISGA B..., IMGA B... ISGH B..., IMGH B...

B
IMGF-B411
C
ISGJ B..., IMGJ B...
D

ISGR B..., IMGR B...


F

G
ISGE B..., IMGE B...

IMGG-B411
I

G.11

32764_G10_G15_E.indd 11 13-07-2005 10:45:38


Series IS and IM
Dimensional drawings

Operating heads (continued)


ISGL B..., IMGL B... ISGC B..., IMGC B...
Limit switches

ISGT B..., IMGT B...

ISGQ B..., IMGQ B...

D ISGV B..., IMGV B...

ISGM B..., IMGM B...

G
ISGP B..., IMGP B...

G.12

32764_G10_G15_E.indd 12 12-07-2005 16:53:37


Series IUG and IUC

Contact block Series IUG Contact block Series IUC


Common for all limit switches Series IUGA B... Common for all limit switches Series IUCA B...

Dimensions
Operating heads
IUGU B..., IUCU B... IUGK B...

IUGR B..., IUCR B...


C

IUGJ B... D

E
IUGH B..., IUCH B...

G
IUGE B..., IUCE B...

IUGI B..., IUCI B...


H

G.13

32764_G10_G15_E.indd 13 12-07-2005 16:53:38


Series IUG and IUC
Dimensional drawings

Operating heads (continued)


IUGL B..., IUCL B... IUGQ B..., IUCQ B...
Limit switches

IUGT B..., IUCT B... IUGM B..., IUCM B...

D IUGP B..., IUCP B...

G.14

32764_G10_G15_E.indd 14 12-07-2005 16:53:39


Series IZ and 114FCT

Series IZ
IZMA IZMH

Dimensions
IZMR IZMS

D
Three pole limit-switches Series 114FCT

G.15

32764_G10_G15_E.indd 15 12-07-2005 16:53:43


Series 115
Pressure switches
• Controlled fluid temperature: 120°C
• Fluids that can be controlled by bellows pressure switches: air and rare
gases, freon, water (sea-water not included), fuel oils, mineral oils, hydraulic
oils and other kinds of fluids that do not corrode steel, tin and other kinds of
fluids that do not corrode steel, tin and copper alloys. To avoid absolutely
and solvents and acids.
• Fluids that can be controlled by piston pressure switches: mineral oils and
hydraulic oils that do not corrode steel and cast iron.
• Synthetic oils with base of phosphates, gas and all the other fluids have to
be excluded.
Limit switches

Setting range choice


On the following pages are shown the values within which it is possible to
make setting of our pressures switches.
For a correct interpretation, consider that:
– The main setting range defines the values within which it is possible to set
the tripping of the pressure switch, when the pressure is decreasing.
– The differential setting range defines the values that, added to those ones of
Standards the main range, determine the tripping when pressure is increasing.
A IEC/EN 60947-5-1 BSI
– The maximum admissible pressure defines the limit that the devices can
stand without consequences. Indicated values have never to exceed also in
CEI UTE the case of occasional overpressure of temporary type.
VDE 0660 When choosing the most suitable type, consider that the device reaches its
B excellent efficiency when the tripping point, with decreasing pressure, is set
between 25% and 75% of the main setting range.
Approvals
C
Setting
(Canada)
– To completely loose the external screw of the main range and the internal
D ASE/SEV (Switzerland) pawl of the differential range.
– By a manometer, to set pressure at the value on which the tripping is
wanted, when pressure is decreasing. To screw the external screw of the
E main range until the tripping of the microswitch (A contact shall result open
and B closed).
– To completely screw the pawl of the differential range, until its maximum
value.
F – To set pressure at the value on which the tripping is wanted, when pressure
is increasing.
– To loosen the pawl of the differential range until the tripping of the
G microswitch (A contact shall result closed and B open).

Tripping point with increasing pressure


H
Differential

I Tripping point with decreasing pressure

G.16

32764_G16_G30_E.indd 16 12-07-2005 16:55:57


Series 115
Location Fixing
Generally the location of our pressure switches can be
effected as wanted.
Nevertheless, as to the piston types whitout seal ring,
location have to be made in such a way as to allow the
discharge, through the drainage hole, of the blow-by oil
between cylinder and piston (a few drops per hour).
The going-out oil can be collected by a proper drainage
pipe that conveys it, free falling, into the tank of the
hydraulic central, as shown in the below figure.

Pressure switches
Caution
To fix the pressure switch on a proper support, use the two
pierceable holes Ø 6.8 mm. located under the cover.
To absolutely avoid to fix it directly on the pipe containing
the fluid to be controlled, use the threaded pipe fitting for
pressure entry.

Setting of the main range

A
Microwitch

Setting of the differential


B
– Do not connect the drainage hole to a return pipe of the
line...
– The drainage pipe must not cover a way different from
that one indicated (e.g. towards the top).
C
Sensitive element
– Do not plug the drainage holes.

If the above cautions are not met, inside the sensitive


Pipe fitting pressure entry
D
group there will be a counter pressure that could damage
the sealing washer between actuator and frame of the
Pipe fitting cables-entry E

G.17

32764_G16_G30_E.indd 17 12-07-2005 16:55:57


Series 115
Pressure switches - Bellows type(1)
Without lighting signalisation Setting range Maximum Weight 1NO - 1NC 2NO - 2NC
Pack.
admissible (kg)
Main Differential pressure Cat. no Ref. no Cat. no Ref. no
Mpa Mpa Mpa
Bar Bar Bar
0.002 - 0.15 0.02 - 0.1 0.4 0.950 115PC002 132500 115PC2002 132504 1
0.02 - 1.5 0.2 - 1 4
0.01 - 0.5 0.04 - 0.1 0.6 0.950 115PC015 132501 115PC2015 132505 1
0.1 - 5 0.4 - 1 6
0.01 - 0.8 0.07 - 0.2 1.55 0.950 115PC018 132502 115PC2018 132515 1
0.1 - 8 0.7 - 2 15.5
0.1 - 1.9 0.12 - 0.2 2.45 0.950 115PC119 132503 115PC2119 132506 1
1 - 19 1.2 - 2 24.5

With lighting signalisation (red lens)(2)


0.002 - 0.15 0.02 - 0.1 0.4 0.950 115PC002L 132507 115PC2002L 132511 1
Limit switches

0.02 - 1.5 0.2 - 1 4


0.01 - 0.5 0.04 - 0.1 0.6 0.950 115PC015L 132508 115PC2015L 132512 1
0.1 - 5 0.4 - 1 6
0.01 - 0.8 0.07 - 0.2 1.55 0.950 115PC018 132509 115PC2018 132513 1
0.1 - 8 0.7 - 2 15.5
0.1 - 1.9 0.12 - 0.2 2.45 0.950 115PC119 132510 115PC2119 132514 1
1 - 19 1.2 - 2 24.5

A Pressure switches - Piston type


Without lighting signalisation Setting range Maximum Weight 1NO - 1NC 2NO - 2NC
Pack.
admissible (kg)
Without seal ring Main Differential pressure Cat. no Ref. no Cat. no Ref. no
B Mpa
Bar
Mpa
Bar
Mpa
Bar
0,95 - 6,9 0,35 - 0,95 69 1,360 115PD970 132520 115PD2970 132523 1
9,5 - 69 3,5 - 9,5 690
1,5 - 20,6 1 - 2,75 69 1,360 115PD15210 132521 115PD215210 132524 1
C 15 - 206 10 - 27,5 690
3,7 - 34,5 1,75 - 2,75 69 1,360 115PD38350 132522 115PD238350 132525 1
37 - 345 17,5 - 27,5 690

D With seal ring 0.95 - 6.9 0.6 - 1.4 69 1.360 115PD970T 132530 115PD2970T 132533 1
9.5-69 6-14 690
1.5 - 20.6 2-4 69 1.360 115PD15210T 132531 115PD215210T 132534 1
15 - 206 20 - 40 690
3.7 - 34.5 3-5 69 1.360 115PD38350T 132532 115PD238350T 132535 1
E 37 - 345 30 - 50 690

F With lighting signalisation (red lens)(2)


0.95 - 6.9 0.35 - 0.95 69 1.360 115PD970L 132540 115PD2970L 132543 1
Without seal ring 9.5 - 69 3.5 - 9.5 690
1.5 - 20.6 1 - 2.75 69 1.360 115PD15210L 132541 115PD215210L 132544 1
G 15 - 206
3.7 - 34.5
10 - 27.5
1.75 - 2.75
690
69 1.360 115PD38350L 132542 115PD238350L 132545 1
37 - 345 17.5 - 27.5 690

H
With seal ring 0.95 - 6.9 0.6 - 1.4 69 1.360 115PD970LT 132550 115PD2970LT 132553 1
9.5-69 6-14 690
I 1.5 - 20.6
15 - 206
2-4
20 - 40
69
690
1.360 115PD15210LT 132551 115PD215210LT 132554 1

3.7 - 34.5 3-5 69 1.360 115PD38350LT 132552 115PD238350LT 132555 1


37 - 345 30 - 50 690

X
(1) Bellows types in stainless steel on request.
(2) Lamp is not delivered. For types see Accessories on G.19.

G.18
Series 115
Accessories
Microswitch Contacts Weight Cat. no. Ref. no. Pack.
1NO - 1NF 0.060 090MI1 130310 25
2NO - 2NF 0.100 090MI2 130311 25

Bellow type Piston type


Sensitive group Basic Weight Standard Stainless steel Without With Pack.
pressure seal ring seal ring
switch Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no.
115PC002 0.045 115807SP 132562 1158065SPA 215320 - - - - 1
115PC015 0.045 115803SP 132563 1158067SPA 215321 - - - - 1
Bellows type 115PC018 0.045 115805SP 132564 1158067SPA 215321 - - - - 1

Pressure switches
115PC119 0.045 115804SP 132565 1158067SPA 215321 - - - - 1
115PD970 0.505 - - - - 1158029-01GI 132566 1158029-03GIT132568 1
115PD15210 0.505 - - - - 1158029-02GI 132567 1158029-04GIT132569 1
115PD38350

Piston type

Weight Cat. no. Ref. no.Pack.


Knob for setting 0.014 115MA 132570 1
main range pressure

Protective cap of 0.078 115CA 132571 100


main range screws

A
Vn AC/DC Wn Weight Cat. no. Ref. no. Pack
Bulb with BA96 6 1.5 0,002 BA9S615 187851 5
base - filament type 12 2 0,002 BA9S122 187852 5
24
30
2
2.1
0,002
0,002
BA9S242
BA9S30
187853 5
187854 5
B
48 2 0,002 BA9S48 187855 5
60 1.2 0,002 BA9S6012 187856 5
130 (110) 2 0,002 BA9S130 187857 5
C
Bulb with BA9s 10 0.11 0,002 BA9SN110 187860 5
base - neon type
D

G.19
Series 115
Technical data
General Electrical performances
The pressure switches Series 115 are designed for trans- 090MI1 (1NO + 1NC)
forming a pressure variation into an electrical signal when 090MI2 (2NO + 2NC)
a pre-arranged pressure value is reached. Rated thermal current: Ith = 10 A
Pressure switches are utilized in the field of the industry
Performances according IEC 947.5.1
machines, installations and transports.
Category AC15 (A600)
Voltage Ue V 24 48 60 110 220 380 500 600
Climatic protections Current Ie A 10 10 10 6 3 2 1,5 1,2
Category DC 13 (P600)
Temperature climate cat. 23/50 (DIN 50014)
Voltage Ue V 24 48 60 110 220 300
Wet climate cat. 23/83 (DIN 50015)
Current Ie A 2.5 1.4 1 0.55 0.27 0.2
Limit switches

Hot wet climate cat. 40/92 (DIN 50015)


Variable wet climate cat. FW24 (DIN 50016)
Performances according to CSA
AC/Heavy Duty (A/600)
DC/Standard Duty (Q300)
Temperature ranges Connections at same polarity
Operation –25°C to +70° C
Storage –40°C to +70°C

Connection terminals
Insulation class Screw type without clamping screw.
IP65 IEC/EN 60529 Suitable for eye, fork and hook terminals.
ENCL. 4, 5 CSA
A
Cable entry
Vibration resistance
One PG 13.5 threaded cable entry.
5g at a sinusoidal frequency ranging IEC 68-2-6
B from to 100 Hz according
to IEC 68-2-6
Range
The pressure switches series 115 are available in two basic
C Mechanical endurance versions:
– With bellows sensitive element for pressures ranging
between 0.002 Mpa
Bellows type (0.02 bar) minimum and 2.1 Mpa (21 bar) maximum.
D 1 million operations. It can be considerably reduced when – With piston sensitive element for pressures ranging
the pressure jump reachs the maximum value foreseen for between 0.95 Mpa
every type of device and the operations number is high. (9.5 bar) minimum and 37.25 Mpa (372.5 bar) maximum.
E The bellows endurance can be also negatively influenced Both versions can be supplied:
by the temperature and the kind of controlled fluid. • Without lighting signaling
• With lighting signaling

F Piston type
3 million operations Construction
Snap-action 1NO-1NC or 2NO+2NC microswitches with
G Rated insulation voltage
double-break contacts without positive-break of the
NC contact.
600V AC/DC Bellows sensitive element, hermetic sealing, made by
Tombacco (or stainless steel) material enclosed into a
H die-cast zamac case complete with a 1 mm. damper.
Insulation class Piston sensitive element, with or without seal ring, with
Group C according to VDE 0110 steel piston enclosed into a cast-iron cylinder complete
with 1 mm. damper.
I Enclosure and cover are made of die-cast aluminium and
Short-circuit protection painted with anaphoresis process grey RAL 7012..
10 A gL fuses according to IEC 947-5-1
X

G.20
Series 115
Dimensions

Pressure switches - Bellows type Pressure switches - Piston type

Pressure switches
A

G.21

32764_G16_G30_E.indd 21 12-07-2005 16:55:59


Safety devices
Safety switches
• Safety switches are used to detect the opening of machine guard doors,
gates or panels to prevent physical access to dangerous areas of the
machine.
• They are designed to help deter tampering with either the internal machine
controls or guards while in an unsafe condition.
• Safety switches are supplied completely assembled, ready to mount to
machine.
• They are available in either a double insulated plastic housing or a robust
metal housing, with or without solenoid locking, having a variety of actuator
types.
• Compliance with standards: IEC/EN 60947-5-1.
Safety devices

Order codes
Lock Operating LED Cat. no. Ref. no. Pack
function voltage
Spring 24V AC/DC no SLSI F BD22 130400 1
Spring 24V DC + no SLSI F UM22 130401 1
24, 110, 230V AC
Solenoid 24V AC/DC yes SLSI M BD22 L 130402 1

Approvals For special applications with interlock


• SLSI can be fitted on moving protective devices as an interlock
A switch or it can be mounted on machinery or plants which
coast dangerously to prevent premature intervention by the
operator.
B Standards • Compact forms, mounting to EN 50041 and connection using
the cage-clamp system.
EN 60204-1 IEC 204-1 • Suitable for high ambient temperatures it’s a multiple-vol-
EN 60947-5-1 IEC 60947-5-1 tage device for the range from 24V AC/DC to 230V, 110 V/AC
C (Standard 24 V AC/DC).
Contact configuration: • Available with spring or magnetic force locking.
- 1NC 1NO, safety guard (actuator) • It can be actuated either horizontally or vertically, allowing very
D - 1NC 1NO, lock flexible installation as the actuator head that can be rotated
through 4x90º.
• Two independent safety circuits monitor the position of the ac-
Electrical features tuator/safety guard and the status of the solenoid/interlocking.
E Switch Rated insulation voltage Ui 250V • Up to two force disconnect contacts are available on both
elements Category of use AC15 230V/2.5A safety circuits.
Rated thermal current Ith 2.5A
Electro Thermal class B (130°)
F magnets Inrush power consumption 56VA (0.2s) Advantages
Permanent power consumpt. 1.1VA
Operating frequency 600 1/h max. • Integrates safety with two independent safety circuits and
flexible contact options (std 1NC+1NO for safety guard and
G Mechanical features 1NC+1NO for locking)
Enclosure + Lid PA6 GV (UL94-V0) • Universal version with multivoltage supply (24-48V DC and 24V
Operating temperature -25 to +70°C 230V AC) Standard 24V AC/DC
Mechanical life 1 x 106 • Flexible mounting options with rotatable actuator head (4x90°)
H Starting speed V = 0.5 m/s max. and horizontal or vertical actuator approach
Mounting 4 x M5 screws
• Protection degree: IP67
Connection capacity 1.5mm2 flex. max.
Terminals Cage clamp • Compact in design (only 170 mm total length)
• Innovative installation by cage clamp terminals
I Cable entry
Assembly
(3x) M20x1.5
Any position • Function complies to IEC/EN 60204-1 and IEC/EN 60947-5-1
Interlocking Spring or magnetic lock
Locking force 1500
Installation
X Protection insulation §

Warning • Mounting with 2xM5 via fixed mounting holes


• The separate actuator has to be secured against unauthorised
• This switch must not be used as a mechanical end stop or accidental loosening
• The interlock of the safety device is maintained on • Before installation the head must be adjusted to horizontal or vertical
power failure only with the type SLSIF.. (spring locking) • This is achieved by changing the upper part of the actuator
• To maintain the safety level, it may only be used toge- head and secured in place by screws provided
ther with the corresponding actuator. • The four actuator approach direction are reached by rotating
the actuator head, after pulling the top mounting plate
Dimensions ! pg. G.28 outwards, to release the rotation lock.
G.22
Safety devices
Safety switches in plastic body
• Plastic-bodied safety switch with separate actuator.
• They are ideal in different applications where protecton of persons is
important.
• Their constructive safety characteristics conform to DIN EN 60947-5-1 and
IEC 947-5-1
• The main application field of these devices inside a process or a machine, is
to switch off the machine drive when a movable protective guard is opened.

Advantages
• High manipulation safety by triple coding
• Tamper proof protection by one way locking of the protective cover of the

Safety switches
actuator key
• person-protection function
• Fail-safe normally-closed contacts
• High reliability due to 2-pole switch-off (2 NC) and 1 additional signalling
contact.
• Galvanic isolation of the contacts
• 3 x M20x1.5 cable entry
• After opening the clip-on lid, the head can be removed from above (version
A); after rotating through 180º (version B), the head can be pushed back
onto the housing and secured using the clip-on-lid. This results in a total of 4
Approvals travel direction.

B
Standards
EN/IEC 60947-5-1
C
Features
• Protected contact
by transparent cover of the
D
Order codes
switching system.
Cat. no. SLSK11 SLSK2001 SLSK0210
• Protection against manipulation Ref. no. 130407 130408 130409
integrated in the switching system Pack 1 1 1 E
by multiple coding.
• Increased function safety - Forced disconnection
according to IEC 60947-5-1.
by two independently operating
locking systems. Chapter 3 F
- Changeover contact galvani-
• Tamper proof protection cally isolated
the protective cover with locking - Slow action contact
device seals the installation screws - Seal inside G
and prevents Contact Actuating
unauthorised access of the operating travel force N
device. (mm) ±10%
±0.25mm H
On Off
1 Operating device in
2 Operating device out
I
Technical characteristics
Rated isolation voltage (Ui) 250/400V AC 400V AC 400V AC
Thermal continuous current (Ithe) 10A 5A 5A X
Making current according to IEC 947-5-1 IEC 947-5-1 IEC 947-5-1
AC15 / 240V 3A AC15 / 240V 3A AC15 / 240V 3A

Max. switching frequency 30 / min. 30 / min. 30 / min.


Mechanical operational life 1 x 106 1 x 106 1 x 106
Ambient temperature -30 ... +80ºC -30 ... +80ºC -30 ... +80ºC
Protection insulation § § §
Dimensions ! pg. G.28

G.23
Safety devices
Safety switch in metal body
• Metal-bodied safety switch with separate actuator.
• Mounting dimensions according to EN50041
• Protection IP65
• Contacts: 1NO+1NC

Order codes
Cat. no. SLSM11
Ref. no. 130406
Pack 1
- Forced disconnection
according to
EN/IEC 60947-5-1. Chapter 3
- Changeover contact
Approvals
Safety devices

galvanically isolated
- Slow action contact
- Seal inside
Contact Actuating
travel force N
(mm) ±10%
±0.25mm
On Off
1 Operating device in
2 Operating device out

Technical characteristics
A Rated isolation voltage (Ui) 400V AC
Thermal continuous current (Ithe) 10A
Making current according to EN/IEC 60947-5-1
AC15 / 240V 3A
B
Max. switching frequency 50 / min.
Mechanical operational life 1 x 106
Dimensions ! pg. G.28 Ambient temperature -30 ... +80ºC
C
Safety switches in plastic body
• Plastic-bodied safety switch with separate actuator.
D • These offer the optimum combination of a cost reducing plastic-bodied
housing and an actuating system for difficult industrial demands.
• The housing, made of glass-fibre reinforced polyamide, fulfils the demands
required for isolated low voltage switching and contact devices. Due to its
E pin shaped geometry, the particulary robust, separate actuator is suitable in
protective equipment.

Order codes
F Cat. no. SLSP11 SLSP02 SLSP0210
Ref. no. 130403 130404 130405
Pack 1 1 1
- Forced disconnection
G Approvals according to
EN/IEC 60947-5-1. Chapter 3
- Changeover contact
galvanically isolated
H - Slow action contact
- Gasket inside
Advantages
Contact Actuating
- Mounting dimensions according to travel force N
I EN50041. (mm) ±10%
- Integrated mounting plate made of metal. ±0,25mm
On Off
- Actuation in horizontal and vertical
20N 20N 20N
X directions.
- A total of 8 actuating directions possible. Technical characteristics
- Safety contacts with positive break and
Voltage (Ui) 400V AC 400V AC 400V AC
galvanic isolation. Thermal continuous current (Ithe) 10A 5A 5A
- Contacts: 1NC+1NO, 2NC or 2NC+1NO Making current according to 240V / 3A 240V / 3A 240V / 1.5A
(with overlapping contacts). IEC 947-5-1 AC15/DC13 (AC15) A300 (AC15) B300 (AC15) B300
- Wiring space with hinged, self-locking lid.
- Protection IP65 Max. switching frequency 30 / min. 30 / min. 30 / min.
Mechanical operational life 1 x 106 1 x 106 1 x 106
Dimensions ! pg. G.28 Ambient temperature -30 ... +80ºC -30 ... +80ºC -30 ... +80ºC

G.24
Safety devices
Safety switches for elevators and escalators
• For monitoring of doors with mechanical reset

Order codes
Cat. no. SLSER11 SLSEP11
Ref. no. 130410 130411
Pack 1 1
- Forced disconnection
according to
EN/IEC 60947-5-1. Chapter 3
- Changeover contact
galvanically isolated
- Slow action contact
SLSER11

Safety switches
- Gasket inside
• Insulating material - DIN EN 50047 Contact Actuating
• Protection IP65 with hinged travel force N
snap-shut lid (mm) ±10% Latching
±0,25mm point
• Easy installation and testing
On Off
• Positive resetting of the switch after
release
• High strength switch enclosures
• Made in accordance with EN 81
Technical characteristics
Voltage (Ui) 250V AC 250V AC
Thermal continuous current (Ithe) 10A 10A
Approvals Making current according to
EN/IEC 60947-5-1 AC15 240V / 3A 240V / 3A A
Max. switching frequency 60 / min. 60 / min.
Mechanical operational life 1 x 106 1 x 106
Ambient temperature -30 ... +80ºC -30 ... +80ºC B
Dimensions ! pg. G.29 Standard actuator Form C Form B

Safety switch for monitoring of hinges, C


flaps and doors
Order codes D
Cat. no. SLSHG11 SLSHA11
Ref. no. 130412 130413
Pack 1 1
E
- Forced disconnection
according to
EN/IEC 60947-5-1. Chapter 3
- Changeover contact
galvanically isolated
F
- Slow action contact
- Gasket inside

Switch Actuating
G
angle force Ncm
°
degree ±10% °
°
±3,5º
SLSHG11 SLSHA11
On Off
H
°
• To monitor and protect of rotating °
° °
guard installations, such as flaps and
doors. According to I
IEC 60947-5-1, EN 60947-5-1 and
Technical characteristics
IEC 60204-1, EN1088, EN 60204-1, Rated isolation voltage (Ui) 250V AC 250V AC
EN292
• Insulating material - DIN EN 50047
Thermal continuous current (Ithe)
Making current according to
10A 10A
X
EN/IEC 60947-5-1 AC15 240V / 3A 240V / 3A

Approvals Max. switching frequency 50 / min. 50 / min.


Mechanical operational life 1 x 106 1 x 106
Ambient temperature -30 ... +80ºC -30 ... +80ºC

Dimensions ! pg. G.29

G.25
Safety devices
Pull rope switches
Technical data
Climatic protections
Temperate climate (DIN 50014) 23 / 50
Wet climate (DIN 50015) 23 / 83
Hot wet climate (DIN 50015) 40 / 92
Variable wet climate (DIN 50016) FW 24
Temperature ranges
Operation -30°C to +80°C
Storage -30°C to +80°C
Degree of protection IEC/EN 60529 IP65

Electrical characteristics
Rated insulation voltage (Ui)
Safety devices

SYDW B211S / SYEW B611 400V AC


SYDW B611 / B611S / B711S 400V A
Electrical shock protection IEC 536 Class I
Short-circuit protection according to IEC 269.1 and 269.3 With fuses type gL of 16A
10A for SYEW B611
Rated thermal current (Ith) 16A
10A for SYEW B611
Rated thermal current (Ithe)
SYDW B211S / SYEW B611 16A
SYDW B611 / B611S / B711S 16A
Characteristics according to UL / CSA AC / heavy duty (A300)
Standards
A IEC 60947-5-1 Contacts / Terminals
EN 60947-5-1 Contact type NO+NC slow motion contacts
galvanically separated

B Approvals
Terminals
Cable entry
Screws M4
2 x (M20x1.5) (lateral)

D Switch function

2 positions type B711S


E Normal position Pulled position

In the normal position When the rope is pulled, contact


G the contact 21-22 is closed and 21-22 opens and 13-14 closes.
13-14 is opened.

H 3 positions type
Normal position Rope pulled Rope failed
Jumper wire instal-
led by customer
I

X
Once the rope has been When the rope is pulled, contact In case of failure of the rope,
prestressing both contacts are 25-26 opens causing contact 13-14 opens causing the
closed. the machine stopping. machine tripping.

G.26
Safety devices
Order codes
Schema Diagram Positions Cat. no. Ref. no. Pack

Without mechanical latch 4.8(1) 3 SYDW B611 213962 1


0 2 4 6mm
13-14
25-26
90N 120N

Pull rope switches


With mechanical latch 3 SYDW B611S 213964 1

4.8(1)
5.5(2)
0 2 4 6mm
13-14
25-26
90N 120N

3 SYDW B711S 213965 1

7(2) A
0 1.5 5 5.8(*) 7.5mm
13-14
25-26
150N 2 40N
B

Mechanical latch function


C
Mechanical latch provides a continuous disconnection of the contact after the rope has been pulled. Hence the
machines remain at a standstill. After the cause for the disturbance has been removed, contacts are reset and work
can be continued.
D

Dimensions ! pg. G.29

G.27
Safety devices
Dimensional drawings
Safety switch for special applications Safety switch in metal body
with interlock
Series SLSM11
Series SLSI.......
Safety devices

A
Safety switch in plastic body Safety switch in plastic body
Series SLSK... Series SLSP...

B Terminal screw
according to
DIN 912 M5

Ø5,5 fixed
D location for
safety application

G.28
Safety devices

Safety switch for elevators and escalators


SLSER11 SLSEP11

Dimensions
Safety switch for monitoring of hinges, flaps and doors
SLSHA11 SLSHG11

Pull rope switches


F
With mechanical latch SYDW-B211S, B611S, B711S

G.29
Everything is
Speed drive units
H.2 VAT20 - Micro AC variable speed drives

H.3 Order codes

H.5 I/O terminal board specifications

H.5 I/0 wiring

H.6 Dimensions and weights

H.8 VAT200 - Mini AC variable speed drives

H.9 Order codes

H.10 Technical data

H.12 EMC compliance

H.12 External accessories

H.13 Dimensions

H.14 VAT2000 - Multimode AC variable speed drives

H.16 Order codes Plug-in relays and Auxiliary contactors A


H.17 Optional PCBs cards

H.18 Technical data Motor protection devices B


H.20 I/O wiring

H.22 I/O terminal board specifications Contactors and Thermal overload relays C
H.30 External accessories

H.32 Dimensions and weights Motorstarters D

H.38 AV300i - Adjustable frequency flux vector drives Control and signalling units E
H.42 Order codes

H.43 Filters and external dynamic braking


Electronic relays F
H.44 Specifications

H.48 Plug-in terminal strip assignement


Limit switches G
H.49 Dimensions and weights
Speed drive units H

Main switches I

Numerical index X

under control H.1


VAT20
Micro AC variable speed drives
• Single-phase or three-phase digital inverters for controlling the speed of
three-phase induction AC motors from 0.2 to 2.2kW
• Built-in keypad and display
• IP20 or IP65 protection degree
• Built-in EMC filter for industrial environment (class A)
• DIN rail mountable by optional kit
• Global standards CE and cUL
Speed drive units

Technical data
A
Control specifications
Control system Sinusoidal wave PWM inverter

B Output frequency
Voltage / Frequency
0 - 200Hz
Constant torque, Constant power, Torque boost
Six selectable pre-set patterns
Overload capacity 150%, 60 sec.
Carrier frequency Selectable 4 - 16kHz
C Frequency setting resolution
Digital 0.1Hz(0-99.9Hz), 1Hz(100-200Hz)
Analogic 0.1Hz/ 60Hz
Acceleration/deceleration 0.1 - 999 sec.
D Acceleration and deceleration set individually
Operating system Two mode selection: forward run by FWD input, Reverse run by REV
input Run by FWD input, forward/reverse command by REV input
Stopping system Selectable either ramp down or coast to stop
E DC braking DC brake starting frequency 1-10Hz
DC braking level 0-20%, DC braking time 0-25.5s
Frequency limit Upper limit (1-200Hz), lower limit (0-200Hz)
Other functions Auto re-start, Auto reset, Flying start, Jog Slow speeds
F
I/O configuration
Operation panel 3 digits, 7 segment display with 5 operation keys
Sequence input Four digital inputs (2 are programmable)
G Sequence output One programmable relay output
Frequency setting input One analogue either 0-10V, 4-20mA or 0-20mA configurable
Source for potentiometer 10VDC source for 2-10kΩ potentiometer
Analogue outputs 0-10VDC for frequency output display
H
Protection features
Prevention Overcurrent limitation, Overvoltage limitation, Stall prevention
Trip Overload, Overvoltage, Undervoltage, Overcurrent, Powerloss,
I Output short-circuit, Grounding fault, Overtemperature

Fault history The last three faults are recorded

X Operating environment
Installation Indoor, with atmosphere free from corrosive or explosive gases, dust, steam or oil mist.
Protection degree IP20 and IP65
Temperature range from -10 to 50 ºC
Relative humidity 0-95% without condensation
Vibrations Under 1G (9.8 m/s2)
Standards cUL, CE

H.2
VAT20
1 phase and 3 phase speed drives
Input voltage Input Output Max. Cooling Losses Protection Cat. no. Ref. no. Pack
+ 10%, -15%, 50/60 Hz (± 5%) power current motor convection degree
power
kVA A kW (1) W
1ph 0.53 1.4 0.2 natural 21 IP20 U20N0K2S 167075 1
200V - 240V 0.88 2.3 0.4 forced 38 IP20 U20N0K4S 167076 1
1.6 4.2 0.75 forced 60 IP20 U20N0K7S 167077 1

Micro AC speed drives


1ph / 3ph 2.9 7.5 1.5 forced 103 IP20 U20N1K5S (2) 167078 1
200V - 240V 4.0 10.5 2.2 forced 149 IP20 U20N2K2S (2) 167079 1

3ph 1.6 2.3 0.75 forced 61 IP20 U20X0K7S (2) 167080 1


380V - 480V 2.9 3.8 1.5 forced 79 IP20 U20X1K5S (2) 167081 1
4.0 5.2 2.2 forced 94 IP20 U20X2K2S (2) 167082 1

1ph 0.53 1.4 0.2 natural 21 IP65 U20N0K2P (3) 167088 1 A


200V - 240V 0.88 2.3 0.4 natural 38 IP65 U20N0K4P (3) 167089 1
1.6 4.2 0.75 natural 60 IP65 U20N0K7P (3) 167090 1

0.53
0.88
1.4
2.3
0.2
0.4
natural
natural
21
38
IP65
IP65
U20N0K2PS (4) 167132
U20N0K4PS (4) 167133
1
1
B
1.6 4.2 0.75 natural 60 IP65 U20N0K7PS (4) 167134 1

C
1ph / 3ph 2.9 7.5 1.5 natural 103 IP65 U20N1K5P (3) 167091 1
200V - 240V 4.0 10.5 2.2 natural 149 IP65 U20N2K2P (3) 167092 1

D
2.9 7.5 1.5 natural 103 IP65 U20N1K5PS (4) 167135 1
4.0 10.5 2.2 natural 149 IP65 U20N2K2PS (4) 167136 1

E
3ph 1.6 2.3 0.75 natural 61 IP65 U20X0K7P (3) 167093 1
380V - 480V 2.9 3.8 1.5 natural 79 IP65 U20X1K5P (3) 167094 1
4,0 5.2 2.2 natural 94 IP65 U20X2K2P (3) 167095 1 F
1.6 2.3 0.75 natural 61 IP65 U20X0K7PS (4) 167137 1
2.9 3.8 1.5 natural 79 IP65 U20X1K5PS (4) 167138 1
4.0 5.2 2.2 natural 94 IP65 U20X2K2PS (4) 167139 1 G

(1) Ratings for standard tree-pole induction motors with four poles.
H
(2) Units including dynamic braking function. An external braking resistor is needed to perform operation.
(3) IP65 models type U20_ _ P include only keypad in the front cover.
(4) IP65 models type U20_ _ PS include power switch, forward/reverse switch and potentiometer in the front cover.
I

H.3
VAT20
Options and accessories
Applicable Cat. no. Ref. no. Pack
to drive
DIN rail kit All drives U20AR0K7 167087 1
(pack of 10 pieces)
Speed drive units

U20N0K2S U20AF0K7 167085 1


EMC filters U20N0K4S
U20N0K7S
U20N1K5S U20AF2K2 167086 1
U20N2K2S
U20X0K7S U20AF2K2X 167084 1
U20X1K5S
U20X2K2S

VAT 20 includes as standard a Class A EMC filter,


for industrial environment.
For residential environment, the use of external
Class B EMC foot print filter is recommended.

Cat. No. A B C D E
A U20AF0K7
U20AF2K2
156
170
76
221
25
38
60
108
145
156
U20AF2K2X 170 221 38 108 156

B
Motor Applicable Cat. no. Ref. no. Pack
(kW) to drive
Braking resistors 1.5 U20N1K5 TLR100P200 108223 1
C 100% braking torque, 10% ED 2.2
0.75
U20N2K2
U20X0K7
TLR75P200
TLR750P200
116300
116301
1
1
1.5 U20X1K5 TLR400P200 116302 1
2.2 U20X2K2 TLR250P200 108227 1

D
65

E 60
195
210

F Losses
(W)
Applicable
to drive
Cat. no. Ref. no. Pack

Reactors Input reactors for single phase drives 2.5 U20N0K2S ACR3A7H0 129788 1
5 U20N0K4S ACR8A2H5 129791 1
7 U20N0K7S ACR12A2H5 129792 1
G 7.5
8
U20N1K5S
U20N2K2S
ACR18A1H3
ACR22A0H84
129793
129794
1
1

Input reactors for three phase drives 11 U20N1K5S ACR6A2H5 129979 1


14 U20N2K2S ACR9A1H3 129980 1
H 8
9
U20X0K7S
U20X1K5S
ACR3A8H1
ACR4A5H1
129989
129990
1
1
11 U20X2K2S ACR6A3H4 129991 1

I Cat. No. A B C D E Ø Weight


(kg)
ACR3A7H0 76 97 84 79 56 7 7
ACR8A2H5 76 97 84 79 56 7 7
X ACR12A2H5
ACR18A1H3
84
96
104 112
113 106
86
95
65
77
7
7
8
9
ACR22A0H84 96 113 116 95 77 7 9

ACR6A2H5 137 146 103 125 102 7 3.2


ACR9A1H3 137 146 113 125 102 7 4
ACR3A8H1 137 146 103 125 102 7 2.8
ACR4A5H1 137 146 103 125 102 7 2.9
ACR6A3H4 137 146 103 125 102 7 3.2

Dimensions in mm

H.4
VAT20
I/O terminal board specifications
Digital inputs
Symbol Description Function
12V Common digital inputs 12VDC supply for all digital inputs
FWD Forward run Used for forward run command
REV Reverse run Used for reverse run command
SP1 Multifunction input This is a programmable digital input
Either jog, slow speed, emergency stop, output shut off or reset function are allowed

Micro AC speed drives


RST Fault reset This is a programmable input set to reset function as default
Either jog, slow speed, emergency and output shut off are allowed as well

Digital outputs
Trip relay Multifunction output This is a programmable output relay set to fault function as default
1,2 Run status and frequency reached are allowed as well

Analogue inputs
MVI Frequency setting Programmable analogue frequency signal input 0-10V, 4-20mA or 0-20mA allowed
0V Common analogue I/O

Analogue outputs
FM Frequency output Analogue output 0-10V. May be used as speed meter
0V Common analogue I/O

Other
+10V 10V DC source 10V DC power supply for potentiometer 2-10KΩ (2W)
A

B
I/O wiring

Power supply C
Single phase drives: L1-L2 or L1-L3
Three phase drives: L1-L2-L3

D
Multifunction
Multifunction input output
E
For factory
test only

2.5 - 10kΩ
F
Earth

H.5
VAT20
Dimensional drawings and weights
Micro speed drive - Protection IP20

Cat. no. Ref. no. Weight (kg)


U20N0K2S 167075 0.76
U20N0K4S 167076 0.77
U20N0K7S 167077 0.8
Speed drive units

Earth .

Dimensions in mm

Cat. no. Ref. no. Weight (kg)


U20N1K5S 167078 1.66
U20N2K2S 167079 1.76
U20X0K7S 167080 1.60
A U20X1K5S 167081 1.60
U20X2K2S 167082 1.63

Earth
B

E Dimensions in mm

H.6
VAT20

Micro speed drive - Protection IP65

Cat. no. Ref. no. Weight (kg)


U20N0K2P 167088 2.9
U20N0K4P 167089 2.9

.
.
.
. U20N0K7P 167090 2.9

Micro AC speed drives


U20N0K2PS 167132 2.9
U20N0K4PS 167133 2.9
U20N0K7PS 167134 2.9
. .

.
.

Dimensions in mm

.
Cat. no. Ref. no. Weight (kg)
U20N1K5P
U20N2K2P
167091
167092
4.8
4.9 A
U20X0K7P 167093 4.9
U20X1K5P 167094 4.9
U20X2K2P 167095 4.9

U20N1K5PS 167135 5.2 B


U20N2K2PS 167136 5.3
U20X0K7PS 167137 5.2
U20X1K5PS 167138 5.2
U20X2K2PS 167139 5?2
C
.

E
Dimensions in mm

Supply cable I
Motor
cable Supply cable

Connection
L1, L2, •
X
terminals Motor cable
•, T1, T2, T3

H.7

32764_H01_H37_E.indd 7 12-07-2005 17:09:29


VAT200

Mini AC variable speed drives


The VAT200 is a well performed, sensorless vector VSD for AC standard motors
available in the following ranges:
- From 0.4 to 2.2kW at 200V, single phase power supply
- From 0.4 to 7.5kW at 200V, three phase power supply
- From 0.75 to 11kW at 400V, three phase power supply

Advantages
• Compact size
Speed drive units

• Built-in removable LED keypad


• Optional multilanguage LCD keypad
• Sensorless vector control or V/f control, selectable
• Built-in with ModBus RTU Communications
• Optional Field bus communication DeviceNet, ProfibusDP
• Integrated EMC filters for U20...FS series
• Built-in with Dynamic Braking
• Performed with simple PLC and PID functions
• Easy start-up & tunning by PC or Keypad
• Advanced programming and drive control by built-in PLC function
• Easy maintenance
Approvals
A
Simple and Reliable
CE cULus UL
B Removable keypad
- LED keypad as standard
- LCD keypad as option

D
Keypad port

Wiring
F Terminal cover removed
by just one screw

Serial port
G For copy unit and communi-
cations

H Configuration switches
- For analogue I/O
- For PNP/NPN digital input selection
I I/O terminals
Supply and Motor

I/O terminals
X Control

I/O terminal
DC reactor

H.8
VAT200
1 phase and 3 phase speed drives
Input voltage Suitable motor Rated output de Rated Frame Cat. no. Ref. no. Pack.
+ 10%, -15%, 50/60 Hz (± 5%) capacity current capacity
(kW) (A) (KVA)

With EMC filter


1ph 0,4 3,1 1,2 1 U201N00K4FS 167400 1
200V - 240V 0,75 4,5 1,7 1 U201N00K7FS 167401 1
1,5 7,5 2,9 2 U201N01K5FS 167402 1
2,2 10,5 4,0 2 U201N02K2FS 167403 1

Without EMC filter

Mini speed drives


Frame 1 1ph 0,4 3,1 1,2 1 U201N00K4SS 167411 1
200V - 240V 0,75 4,5 1,7 1 U201N00K7SS 167412 1
1,5 7,5 2,9 2 U201N01K5SS 167413 1
2,2 10,5 4,0 2 U201N02K2SS 167414 1

Without EMC filter


3ph 0,4 3,1 1,2 1 U203N00K4SS 167415 1
200V - 240V 0,75 4,5 1,7 1 U203N00K7SS 167416 1
1,5 7,5 2,9 1 U203N01K5SS 167417 1
2,2 10,5 4 2 U203N02K2SS 167418 1
3,7 17,5 6,7 2 U203N04K0SS 167419 1
5,5 26 9,9 3 U203N05K5SS 167420 1
7,5 35 13,3 3 U203N07K5SS 167422 1 A
Frame 2
With EMC filter
3ph 0,75 2,3 1,7 1 U203X00K7FS 167404 1 B
380V - 480V 1,5 3,8 2,9 1 U203X01K5FS 167405 1
2,2 5,2 4 2 U203X02K2FS 167406 1
3,7 8,8 6,7 2 U203X04K0FS 167407 1
5,5 13 9,9 3 U203X05K5FS 167408 1
7,5 17,5 13,3 3 U203X07K5FS 167409 1 C
11 25 19,1 3 U203X11K0FS 167410 1

Without EMC filter D


3ph 0,75 2,3 1,7 1 U203X00K7SS 167424 1
380V - 480V 1,5 3,8 2,9 1 U203X01K5SS 167425 1
2,2
3.7
5,2
8,8
4
6,7
2
2
U203X02K2SS
U203X04K0SS
167426
167427
1
1 E
5,5 13 9,9 3 U203X05K5SS 167428 1
7,5 17,5 13,3 3 U203X07K5SS 167429 1
Frame 3 11 25 19,1 3 U203X11K0SS 167430 1
F

Accessories G
Cat. no. Ref. no. Pack.

Communications interface Profibus-DP U200APB 167433 1


DeviceNet
RS485
U200ADN
U200ARS485
167434
167435
1
1
H
Communications interface U200ARS232 167436 1
U200AMP / 167437
Memory pack U200AMP 167437 1
I
Keypad LED U200ALEDK 167438 1
LCD U200ALCDK 167439 1
Blank cover U200ABK 167440 1
U200ARS485 / 167435 X
Remote wire for keypad 0,5m U200AW05 167441 1
1,0m U200AW10 167442 1
2,0m U200AW20 167443 1
3,0m U200AW30 167444 1
5,0m U200AW50 167445 1
U200ARS232 / 167436

H.9
VAT200
Technical data

General specifications
1ph 200-240V 3ph 200-240V 3ph 380-480V
(with / without EMC filt.) (without EMC filter) (with / without EMC filter)
U201N_____S U203N____SS U203X_____S
00K4 00K7 01K5 02K2 00K4 00K7 01K5 02K2 04K0 05K5 07K5 00K7 01K5 02K2 04K0 05K5 07K5 11K0
Motor ratings (HP) 0,5 1 2 3 0,5 1 2 3 5,5 7,5 10 1 2 3 5,5 7,5 10 15
(kW) 0,4 0,75 1,5 2,2 0,4 0,75 1,5 2,2 3,7 5,5 7,5 0,75 1,5 2,2 3,7 5,5 7,5 11
Rated output current (A) 3,1 4,5 7,5 10,5 3,1 4,5 7,5 10,5 17,5 26 35 2,3 3,8 5,2 8,8 13 17,5 25
Rated capacity (kVA) 1,2 1,7 2,9 4 1,2 1,7 2,9 4 6,7 9,9 13,3 1,7 2,9 4 6,7 9,9 13,3 19,1
Speed drive units

Maximum input voltage Single phase: 200-240V Three phase: 200-240V Three phase:
+10 -15%, 50/60Hz ±5% +10 -15%, 50/60Hz ±5% 380-480V, +10 -15%, 50/60Hz ±5%
Maximum output voltage Three phase: 0 - 240V Three phase: 0 - 240V Three phase: 0 - 480V
Input current (A) 8,5 12 19 27 4,5 6,5 11 15,4 20 29 40 4,2 5,6 6 10,2 15 20,5 30,2

Frequency control
Control mode V /f or Sensorless vector control
Range 0,1 to 650,0Hz
Starting torque 150% / 1Hz (Sensorless vector)
Speed control range 1 : 50 (Sensorless vector)
Speed control accuracy ±0,5% (Sensorless vector)
Setting resolution Digital : 0,01 Hz
Analog: 0,06Hz / 60Hz (10 bits)
Keypad setting Set directly by 56keys or by potentiometer on the keypad
A Display function Four digital LED (or 2x16 LCD) and status indicator; display frequency / speed / line speed /
DC voltage / output voltage / current / rotation direction / inverter parameter / trouble log / program version
Frequency setting 1. External potentiometer / 0-5V / 0-10V / 4-20mA / 5-0V / 10-0V / 20-4mA
2. Performs up/down controls, speed control or automatic procedure control with multifunctional contacts on
B the terminal block (TM2)
Frequency limit function Respectively setting upper/lower frequency limits and three-stage skip frequencies

C Control
Carrier frequency 2 to 16kHz
V / F pattern 18 fixable patterns, 1 programmable pattern
Acc./Dec. control Two-stage Acc./Dec. time (0,1 to 3.600 seconds) and two-stage S curve
Multifunctional analog output 5 different functions
D Multifunctional input Assigned to 28 different functions
Multifunctional output Assigned to 15 different functions
Digital input signal NPN / PNP toggle
Other functions Momentary power loss restart, Speed search, Overload detection, Torque detection, 8 preset speeds, Acc./Dec. switch
E (2 stages), S curve, 3-wire control, PID control, Torque boost, Slip compensation, Frequency upper/lower limit, Auto
energy saving, Modbus slave and control link, Abnormal restart, Sequence control, Built-in simple PLC function

F Others
Communication control - Control by RS232 or RS485
- One to one or Multilink up to 254 stations (RS485 only)
- Can be set Baud rate, Stop bit and Parity bit
G Braking torque
Operation temperature
About 100% with Braking resistor (20% without braking resistor)
-10 to +50ºC
Storage temperature -20 to +60ºC
Humidity 0 to 95% relative humidity (without condensation)
Vibration
H EMC
1G (9,8m/S2)
Comply with requirement EN 61800-3 with optional filter
LVD Comply with requirement EN 50178
Enclosure IP20 (NEMA 1 by external box attached)
Safety level UL 508C
I
Protective functions
Overload protection Inverse characteristic overload protection. Max. 150% inverter current rating / 60 sec.
X Fuse protection
Overvoltage
The motor stops after FUSE melt
200V class: DC voltage > 410V 400V class: DC voltage > 820V
Undervoltage 200V class: DC voltage < 190V 400V class: DC voltage < 380V
Momentary power loss restart Restart after more than 15ms-power loss possible. Programmed up to 2 sec.
Stall prevention Stall prevention for Acceleration / Deceleration / Operation
Short-circuit output terminal Electronic circuit protection
Grounding fault Electronic circuit protection
Other protections Heatsink overtemperature, overtorque detection, error contact control, reverse run restriction, restrictions for direct start
after power up, error recovery and parameter lock out.

H.10
VAT200
I/O Power & Control layout

DC coil DBR

MCCB

Mini speed drives


Serial port

Power terminals A
Power supply input L1, L2, L3
Motor output T1, T2, T3
DC Reactor
DB Resistor
P1, P
P, BR
B

Control terminals
C
Analog inputs Multifunction AIN
PID feedback S6
Analog outputs Multifunction FM
Digital inputs S1, S2, S3, S4, S5, S6 D
(dual use)
Digital outputs R1 (NO-NC dry relay
contact)
R2 (NO dry relay E
contact)

I/O Control terminal description


G
Symbol Description
R2A
R2B
Multifunctional terminals - Normally Open
Multifunctional terminals - Normally Open Contact rated capacity
H
R1C Common contact Multifunctional terminals 250VAC/1A or 30VDC/1A
R1B Normally Closed contact Normally Open
R1A Normally Open contact
10V Frequency knob (VR) power source terminal I
AIN Analog frequency signal input terminal
24V Common source for S1 to S5 in PNP input.
Selectable by switch on main PCB
COM Common terminal for S1 to S5 in NPN input. X
Selectable by switch on main PCB
FM + Multifunction analog output, 0-10V DC
S1 Multifunction input terminals
S2 Multifunction input terminals
S3 Multifunction input terminals
S4 Multifunction input terminals
S5 Multifunction input terminals
S6 / AV2 Digital input or PID input terminal (selectable)

H.11
VAT200
External accessories
VAT200 AC Reactors DC Reactors Encapsulated Resistor Tubular resistors
1ph 200-240V U201N00K4FS 167400 ACR8A2H5 129791 DCR4A5H7 168387 ERN00K7 129148 TLR200P200 129165
With U201N00K7FS 167401 ACR12A2H5 129792 DCR6A3H9 168388 ERN00K7 129148 TLR200P200 129165
EMC filter U201N01K5FS 167402 ACR18A1H3 129793 DCR9A2H4 168389 ERN01K5 129149 TLR100P200 108223
U201N02K2FS 167403 ACR22A0H84 129794 DCR12A1H7 168390 ERN02K2 129150 TLR75P200 116300
U201N00K4SS 167411 ACR8A2H5 129791 DCR4A5H7 168387 ERN00K7 129148 TLR200P200 129165
Without U201N00K7SS 167412 ACR12A2H5 129792 DCR6A3H9 168388 ERN00K7 129148 TLR200P200 129165
EMC filter U201N01K5SS 167413 ACR18A1H3 129793 DCR9A2H4 168389 ERN01K5 129149 TLR100P200 108223
U201N02K2SS 167414 ACR22A0H84 129794 DCR12A1H7 168390 ERN02K2 129150 TLR75P200 116300

3ph 200-240V U203N00K4SS 167415 ACR4A2H5 129978 DCR4A5H7 168387 ERN00K7 129148 TLR200P200 129165
Without U203N00K7SS 167416 ACR6A2H5 129979 DCR6A3H9 168388 ERN00K7 129148 TLR200P200 129165
U203N01K5SS 167417 ACR9A1H3 129980 DCR9A2H4 168389 ERN01K5 129149 TLR100P200 108223
Speed drive units

EMC filter
U203N02K2SS 167418 ACR12A0H84 129981 DCR12A1H7 168390 ERN02K2 129150 TLR75P200 116300
U203N04K0SS 167419 ACR18A0H56 129982 DCR18A1H0 168391 ERN04K0 129151 TLR44P600 129166
U203N05K5SS 167420 ACR27A0H37 129983 DCR32A0H78 168371 ERN05K5 129152 TLR29P600 129167
U203N07K5SS 167422 ACR35A0H27 129984 DCR45A0H55 168372 ERN07K5 129153 TLR22P600 129168

3ph 380-480V U203X00K7FS 167404 ACR3A8H1 129989 DCR3A15H2 168392 ERX00K7 129154 TLR750P200 116301
With U203X01K5FS 167405 ACR4A5H1 129990 DCR4A9H2 168393 ERX01K5 129155 TLR400P200 116302
EMC filter U203X02K2FS 167406 ACR6A3H4 129991 DCR6A6H8 168394 ERX02K2 129156 TLR240P200 108227
U203X04K0FS 167407 ACR10A2H 129992 DCR9A4H0 168395 ERX04K0 129157 TLR175P600 129173
U203X05K5FS 167408 ACR14A1H4 129993 DCR18A2H9 168380 ERX05K5 129158 TLR118P600 129174
U203X07K5FS 167409 ACR18A1H1 129994 DCR25A2H1 168381 ERX07K5 129159 TLR86P600 129175
U203X11K0FS 167410 ACR27A0H75 129995 DCR32A1H6 168382 TLR43P1000 129177
Without U203X00K7SS 167424 ACR3A8H1 129989 DCR3A15H2 168392 ERX00K7 129154 TLR750P200 116301
EMC filter U203X01K5SS 167425 ACR4A5H1 129990 DCR4A9H2 168393 ERX01K5 129155 TLR400P200 116302
U203X02K2SS 167426 ACR6A3H4 129991 DCR6A6H8 168394 ERX02K2 129156 TLR240P200 108227
U203X04K0SS 167427 ACR10A2H 129992 DCR9A4H0 168395 ERX04K0 129157 TLR175P600 129173
A U203X05K5SS 167428 ACR14A1H4 129993 DCR18A2H9 168380 ERX05K5 129158 TLR118P600 129174
U203X07K5SS 167429 ACR18A1H1 129994 DCR25A2H1 168381 ERX07K5 129159 TLR86P600 129175
U203X11K0SS 167430 ACR27A0H75 129995 DCR32A1H6 168382 TLR43P1000 129177

B
EMC compliance
C Drives with built-in filter type U20....FS, comply with EN 61800-3 second environment.
To comply with first environment restricted sector, or to allow EMC compliance to U20....SS drives, an external
filter has to be used according following table

D VAT200 Second First


environment environment
1ph 200-240V U201N00K4FS 167400 Not needed U200F611TA1 167453
U201N00K7FS 167401 Not needed U200F611TA1 167453
E With
EMC filter U201N01K5FS 167402 Not needed U200F627TA2 167454
U201N02K2FS 167403 Not needed U200F627TA2 167454
Without U201N00K4SS 167411 U200F611TA1 167453
EMC filter U201N00K7SS 167412 U200F611TA1 167453
U201N01K5SS 167413 U200F627TA2 167454
F U201N02K2SS 167414 U200F627TA2 167454

3ph 200-240V U203N00K4SS 167415 U200F709TA1 167456


G Without
U203N00K7SS
U203N01K5SS
167416
167417
U200F709TA1
U200F709TA1
167456
167456
EMC filter U203N02K2SS 167418 U200F719TA2 167457
U203N04K0SS 167419 U200F719TA2 167457
U203N05K5SS 167420 U200F739TA3 167458
H U203N07K5SS 167422 U200F739TA3 167458

3ph 380-480V U203X00K7FS 167404 Not needed U200F905TA1 167459


With U203X01K5FS 167405 Not needed U200F905TA1 167459
I EMC filter
U203X02K2FS
U203X04K0FS
167406
167407
Not needed
Not needed
U200F910TA2
U200F910TA2
167460
167460
U203X05K5FS 167408 Not needed U200F928TA3 167461
U203X07K5FS 167409 Not needed U200F928TA3 167461
U203X11K0FS 167410 Not needed U200F928TA3 167461
X Without U203X00K7SS
U203X01K5SS
167424
167425
U200F905TA1
U200F905TA1
167459
167459
EMC filter
U203X02K2SS 167426 U200F910TA2 167460
U203X04K0SS 167427 U200F910TA2 167460
U203X05K5SS 167428 U200F928TA3 167461
U203X07K5SS 167429 U200F928TA3 167461
U203X11K0SS 167430 U200F928TA3 167461

H.12
VAT200
Dimensions
Speed drive

Mini speed drives


Weight kg Dimensions (mm) Weight kg Dimensions (mm)
Series Series
SS FS A B C D E F G SS FS A B C D E F
U201N00K4..
U201N00K7..
1.2
1.2
1.3
1.3
163 150 78 90 147 141 7 U203N05K5..
U203N07K5..
5.6
5.6
-
-
260 244 173 186 195 188 A
U203N00K4.. 1.2 - U203X05K5.. 5.6 6.6
U203N00K7.. 1.2 - U203X07K5.. 5.6 6.6
U203N01K5.. 1.2 - U203X11K0.. 5.6 6.6
U203X00K7..
U203X01K5..
1.2
1.2
1.3
1.3
B
U201N01K5.. 1.5 1.8 187 170,5 114,5 128 148 142 7
U201N02K2.. 1.9 2.3
U203N02K2.. 1.75 -
U203N04K0..
U203X02K2..
1.9
1.8
-
2.2
C
U203X04K0.. 1.9 2.3

Braking resistor
D
A B C D E
ERN00K7 129148 115 80 175 40 20 E
ERX00K7 219154
ERN01K5 129149 215 200 175 40 20
ERX01K5 129155
ERN02K2 129150 165 150 125 60 30
ERX02K2 129156 F
ERN04K0 129151 215 200 175 60 30
ERX04K0 129157
ERN05K5 129152 335 320 295 60 30
ERN07K5 129153
ERX05K5 129158 G
ERX07K5 129159

H
EMC external filter
I
Inverter External External
mounting Filter size filter mount.
A B C D E F G
U200F611TA1
U200F709TA1
167453 78 150
167456
91 192 28 74 181 X
U200F905TA1 167459
U200F627TA2 167454 114,5 170,5 128 215 37 111 204
U200F719TA2 167457
U200F910TA2 167460
U200F739TA3 167458 173 244 188 289 42 165 278
U200F928TA3 167461

H.13
VAT2000
Multimode 3 ph variable speed drives
for AC motors
VAT2000 is a compact, maintenance free, reliable AC drive for three phase
220-240V or 380-460V power source, allowing high accuracy speed control of
standard AC motors.

VAT2000 is an open platform using the latest technology in both


hardware and software, providing advanced application functions
and full motor protection.
Speed drive units

Features and Benefits


The VAT2000 is a new generation of
high performance vector AC drives. • All in one multimode drive:
A Between 10% and 30% smaller than - Sensorless vector control
the former range and using the latest - Very high performance vector control with sensor
32 bits microprocessors, the new range - V/F, advanced torque control
covers the power ratings from 0.4 to - PM drive
B 315kW in constant torque, and up to
370kW in variable torque applications. • Easy to operation:
- Rotary knob
C As well as satisfying industry’s - Autotuning for vector control
requirement for a top performance - Removable keypad
drive, the VAT2000 is hailed as a truly
environmentally friendly drive. Coupled • Environmentally friendly design:
D with a PM motor this drive can offer up - Up to 20% energy saving using a permanent magnet motor
to 20% increase in energy efficiency at - Dedicated energy saving function for induction motors
2.2kW, saving energy costs. The carefull - Drives plastic components are free of harmful dioxins
selection of materials means that the
E drives plastic components are free of
- Soft sound PWM

harmful dioxins, and a new soft sound • Exceptional pack of monitoring, protection and operating functions
performance significantly reduces
F noise pollution by randomly altering • Conform to global standards
the carrier frequency during operation.

G Removable keypad Other features


- Extended I/O range
- Advanced functions
H - Autotuning
- Torque control
- Soft sound
- PID control
I - Multipump control
- Pattern run
- Programmable speeds
X - Traverse function
- Skip frequency
Approvals - Speed ratio control
- “S” shape ramp
CE compliance - Communications
UL approval (UL508C) 400V series up to - Built-in RS485 port
U2KX45K0S only. - Optional Profibus DP interface

H.14
VAT2000
Multi-mode vector drive

Mode 1 Mode 3
V/F control for constant torque loads with advanced Sensorless vector control
toruqe control There are many drives which claim to offer sensorless
This mode uses auto-tuning to give voltage vector control vector control but we feel that this term is misused and

Multimode speed drives


in open loop. describes a control system similar to our standard Ad-
The main features of this mode are: vanced Torque Control. We define true Sensorless Vector
1. Built-in PID controller eliminates the requirement, and Control as Flux Vector Control without encoder. Closed
cost, of a separate device. loop vector control requires the use of an encoder so that
2. Tripless operation. This safe and convenient fetaure is a shaft position can be used in order to calculate and control
combination of: phase angle and shaft speed. Because of this, all settings
- the availability of dinamically extend ramp times within a closed loop environment relate to actual shaft
during operation if the load is likely to demand a too rotation rather than output frequency.
high current or regenerate a higher current than the Developing a method whereby the shaft rotation can be
programmed limit. calculated by very closely monitoring the waveform and
- automating limiting of the IGBT switching frequency if feedback at three output phases of the drive. All of the
the heatsink temperature rises too high. settings the VAT2000 in sensorless vector mode are
- the ability to limit current transients caused by shock therefore set using rotational speed and not output
loads. frequency.
- alarms and controlled shutdown in the event of a fault In addition, incorporate two current loops to control
which is non-life threatening of the drive motor. magnetising current independently. Thus, the VAT2000
3. “Motor Loss Braking” is a system which reduces motor
efficiency during regenerative braking allowing some of
can perform almost as well as a closed loop system and A
uniquely provide torque at zero speed.
the braking energy to be dissipated from the motor as
heat, so reducing the size (or even eliminating) the brake
resistor. Mode 4 B
Closed loop vector control
Mode 2 This advanced mode enables motor speed to be varied C
across a 1000 : 1 speed range, with 0.01% accuracy up to
V/F control for variable torque loads with advanced 6 times faster than conventional drives
torque control (30Hz response time).
This mode uses auto-tuning to give voltage vector control In addition to outstanding torque performances, this mode D
in open loop with the added benefit that, because of a contains a new feature whereby the loss of the encoder
higher continuous current rating than in constant torque signal will cause the drive to automatically switch into
mode, an inverter of one size lower may be used in order to Sensorless Vector mode. The drive then issues an alarm E
reduce the purchase cost. signal which can be used as an indicator or as a
Features include: shutdown signal. Closed loop vector control requires an
1. Special energy saving features for fans and pumps encoder feedback card.
where V/F ratios are dynamically controlled to optimise F
the power usage.
2. The drive can auto-tune to two independent motors, Mode 5
so that one inverter can be used in apllications such as
pumping where a main and standby pump are fed by
G
the same source. PM motor control
3. Multi-pump control. This is a logogic control system This mode enables the use of ultraefficient PM motors for
energy conservation.
commonly used where two or more pumps maintain H
pressure in a system, one being variable speed abd
the others being brought in as required.

H.15
VAT2000
Multimode 3 ph speed drive
Heavy duty / Constant torque (1) Light duty / Variable torque (2)
Input voltage overload 150% 60 sec. overload 120% 60 sec. Protection Cat. no. Ref. no.
Input Output Maximum (3) Input Output Maximum (3) degree
power current motor power power current motor power
kVA A kW kVA A kW

3ph 1 3 0.4 1.2 5 0.75 IP20 U2KN00K4S 168000


200V - 230V 1.7 5 0.75 2.1 8 1.5 IP20 U2KN00K7S 168001
2.7 8 1.5 3.0 11 2.2 IP20 U2KN01K5S 168002
3.8 11 2.2 5.1 16 4 IP20 U2KN02K2S 168003
5.5 16 4 7.6 22 5.5 IP20 U2KN04K0S 168004
8.3 24 5.5 10.0 33 7.5 IP20 U2KN05K5S 168005
11.4 33 7.5 14.5 42 11 IP20 U2KN07K5S 168006
15.9 46 11 19.3 61 15 IP20 U2KN11K0S 168007
21.1 61 15 24.2 76 18.5 IP20 U2KN15K0S 168008
Speed drive units

26.3 76 18.5 29.7 86 22 IP00 U2KN18K5S 168009


31.8 92 22 37.4 108 30 IP00 U2KN22K0S 168010
41 118 30 45 134 37 IP00 U2KN30K0S 168011
50 144 37 55 161 45 IP00 U2KN37K0S 168052

3ph 1 1.5 0.4 1.7 2.5 0.75 IP20 U2KX00K4S 168024


380V - 460V 1.7 2.5 0.75 2.5 3.6 1.5 IP20 U2KX00K7S 168025
2.5 3.6 1.5 3.8 5.5 2.2 IP20 U2KX01K5S 168026
3.8 5.5 2.2 5.9 8.6 4 IP20 U2KX02K2S 168027
5.9 8.6 4 9.0 13 5.5 IP20 U2KX04K0S 168028
9 13 5.5 11.7 17 7.5 IP20 U2KX05K5S 168029
11.7 17 7.5 15.9 23 11 IP20 U2KX07K5S 168030
15.9 23 11 21.4 31 15 IP20 U2KX11K0S 168031
21.4 31 15 25.6 37 18.5 IP20 U2KX15K0S 168032
25.6 37 18.5 30.4 44 22 IP20 U2KX18K5S 168033
30.4 44 22 41.5 60 30 IP00 U2KX22K0S 168034
A 41.5
50
60
72
30
37
50.5
55
73
84
37
45
IP00
IP00
U2KX30K0S
U2KX37K0S
168035
168036
60 87 45 75 108 55 IP00 U2KX45K0S 168037
75 108 55 100 147 75 IP00 U2KX55K0S 168038
100 145 75 120 179 90 IP00 U2KX75K0S 168039
B 120
150
173
214
90
110
140
170
208
242
110
132
IP00
IP00
U2KX90K0S
U2KX110KS
168040
168041
170 245 132 200 293 160 IP00 U2KX132KS 168042
220 321 160 250 365 200 IP00 U2KX160KS 168043
300 428 200 330 479 250 IP00 U2KX200KS 168044
C 350
400
519
590
250
315
400
450
581
651
315
370
IP00
IP00
U2KX250KS
U2KX315KS
168045
168046

(1) Heavy duty / Constant torque ratings


D - Ambient temperature -10ºC to 50ºC for all range.
- Drives up to U2KN22K0S or up to U2KX30K0S allow specified current ratings when carrier frequency is set up to 10KHz.
Above 10KHz, derate output current by 7% per 1KHz.
- Drives above U2KN22K0S or U2KX37K0S and above allow specified current ratings when carrier frequency is set up to 4KHz.
Above 4KHz, derate output current by 7% per 1KHz.
E (2) Light duty / Variable torque ratings
- Ambient temperature -10ºC to 50ºC. For drives up to U2KN7K5S derate output current by 2% per 1ºC if ambient
temperature exceeds 40ºC.
- Maximum recommended carrier frequency is 4KHz. Higher carrier frequency is allowed if drive’s output current is derated
F according following expression:
VT - CT
Amps, per 1KHz
6
VT = Drive rated current in variable torque
CT = Drive rated current in constant torque
G - Ratings are given for standard four poles motors. Otherwise, check motor nameplate.

Remark: More information is given in User Manual

(3) Ratings given are for standard 4 poles induction motors


H

H.16
VAT2000
Optional PCBs Cards
Description Cat. no. Ref. no.

Multimode speed drives


Encoder interface 12V A/B phase 60kHz; 6V single phase 20kHz, U2KV23DN1 168087
12VDC 100mA supply output
5V A/B phase differential 250kHz; 5VDC 200mA U2KV23DN2 168088
5VDC 100mA supply output
5V 6 phase (A, B, Z, U, V, W) 250Hz for permanent U2KV23DN3 168089
magnet motors
5VDC 100mA supply output

Relay interface 4 additional programmable inputs U2KV23RY0 168090


2 additional programmable relay outputs

Parallel interface Frequency setting through parallel 8/12/16 data bits U2KV23PI0 168091
A
Multi-pump dedicated relay Provides rotation of main pump U2KV23RY1 168050
interface B
Communication Interfaces Serial communication interface Additional RS232C/485 serial port U2KV23SL0 168092

C
Profibus DP communication Standard field bus interface U2KV23SL6 168093
interface

DeviceNet Communications Standard field bus interface U2KV23SL8 168047 D


Interface

CAN open Standard field bus interface U2KV23SL7 168048


E
CC-link interface Standard field bus interface U2KV23SL9 168049

Accessories Extension cable for keypad 3m U2KV23W103 168102


H
Extension cable for keypad 1m U2KV23W101 168103
Drive to terminals RS485 cable U2KV23W123 168104
Drive to 15 pin D-sub connector U2KV23W113 168105
RS485 cable
Drive to PC RS232 cable Includes RS232/485 converter U2KV23CNVKIT168106
I

H.17
VAT2000
Technical data
Frequency control
Control method All digital control sine wave approximation PWM
Carrier frequency
Mono-sound mode 1 to15kHz (1kHz increments)
1 to 8kHz for drives above U2KX45K0S
Soft sound mode Average frequency 2.1 to 5kHz with 3 or 4 tone modulation
Output frequency resolution 0.01Hz
Frequency setting resolution
Digital 0.01Hz
Analogue 0.025%, respect maximum frequency
Frequency accuracy
Speed drive units

Digital ± 0.01% at 25 ±10ºC


Analogue ± 0.1% at 25 ±10ºC
Output frequency From 0 to 440Hz in V/f control mode
From 0 to 120Hz in Vector control mode

Control specifications
Voltage frequency control Constant torque, constant output and reduction torque set in range from 3 to 440Hz
Torque Boost: Manual and automatic
Max. torque boost: allows improved V/f control
Vector control Sensorless With sensor For PM motors
Control range 1 : 100 1 : 1000 1 : 100
Constant output range(*) Up to 1 : 2 Up to 1 : 4 Up to 1 : 1.2
Speed accuracy (at Fmax. G 50Hz) ± 0.5% ± 0.01% ± 0.01%
Control response 5Hz 30Hz -
A Automatic tuning Automatic measurement of motor constants and setting of critical parameters.
There are two independent Auto-tuning for all control modes.
Starting torque 200% or more
Acceleration/deceleration time 0.01 to 60000 sec.

B Two sets of independent acceleration/deceleration, plus one set for jogging and eight sets
more for program ramp function
Acceleration/deceleration mode Linear and S type ramp selection
Operating system - Forward run or reverse run using two external dry contacts
(3 modes selectives) - Run/Stop and forward/reverse changeover using two external dry contacts
C - Forward/Reverse run and stop using three external push-buttons
Stop system Selectable either Ramp down to stop or coast to stop,
independently for run, jog and EMS
DC braking - Braking stop frequency, set between 0.1 and 60.0Hz
D - Braking voltage, set between 0.1 and 20.0%
- Braking time, set between 0.0 and 20.0 s.
(*) from 150 to 7200 rpm (max. 120Hz)
Operation functions
E Multi speed 8 fixed speed selectable with independent acceleration/deceleration ramps
for each speed
Ratio interlock Output frequency or speed is operating according:
Y = Ax + B + C
F x : frequency or speed setting
A : (gain) 0.000 to ±10.000
B : 0.00 to ± 440Hz (0 to ±7200min-1 with max.:120Hz in Vector control mode)
C : auxiliary input (AUX)
G Upper and lower limits available
Frequency jump Up to three areas / Width can be varied between 0.0 and 10Hz
Slip compensation Slip compensation gain for V/f operation only from 0.0 to 20.0%
Auto-run function 10-step automatic run function / Synchronous / Asynchronous selective
H Others PID, Pick-up, Auto-start, Traverse, Multipump control, reverse run protection and Restart
after instantaneous power failure

H.18
VAT2000
Technical data (continued)
External I/O
Operation keypad Detachable IP54 unit with 5 digit LED display and eight status LED signals.
Includes three set keys and fast tuning knob system.
Door mountable by 3m extension cable
Input sequence Three fixed inputs and five programmable to more than 30 functions
Output sequence One fixed dry contact (fault), one dry contact and three open collector outputs all
programmable to more than 20 functions, like speed detection precharging, reverse run,

Multimode speed drives


speed reached, direction, current reached, speed, acceleration, fault code, etc
Frequency settings FSV: 0 to 10V / 0 to 5V / 1 to 5V
FSI: 4 to 20mA / 0 to 20mA
AUX: 0 to ±10V / 0 to ±5V / 1 to 5V
Source potentiometer: 10V DC (2k2Ohms)
Meter outputs Two 0-10V programmable with output frequency, voltage, current, DC voltage, etc

Protection features
Prevention Overcurrent and Overvoltage limit, Overload warning signal
Trip Overcurrent, overvoltage, undervoltage, IGBT fault, overload, temperature rise, ground
fault, other self-diagnosis
Fault history The last four faults are recorded including in each:
main cause, secondary cause, output current and output frequency at the fault time
Overload level CT: 150% for 1 minute, 170% for 2,5 seconds
VT: 120% for 1 minute, 125% for 1second
For frequencies below 1Hz, overload of 75% during 60 seconds
Retry Automatic reset after a fault. Adjusable from 0-10 tries

Operating environment A
Installation Indoor, with atmosphere free from corrosive or explosive gases, dust, steam or oil mist
Working temperature -10 to +50ºC
Relative humidity max. 95% RH, non condensing
Altitude
Vibrations
1000 m. max.
4.9 m/s
2 B

H.19
VAT2000
I/O wiring

DBR driving unit (option) (3)


Speed drive units

A MCCB MOTOR

POWER
B SUPPLY

ANALOGUE INPUT
C Frequency
setting ANALOGUE OUTPUT
(voltage)
2k2Ω, 2W
D Frequency
(5) Voltage
output
setting (0-10V)
(current) load max.
Aux. setting (5) 1mA
E DC ± 10V
(5)

DC 0-10V

DIGITAL OUTPUT
F DIGITAL INPUT
Max. 1A 250V AC To comply
or 30V DC with UL, use at
30VAC/DC
G or lower
Max. 0,4A 250V AC
or 1A 30V DC
Standard setting
Free voltage
H input
(5mA per
signal)
Open collector
I Max. 30VDC 50mA

X
RY0V (4)

(1) Remove the link between L1 - L2 it using optional DC reactor


(2) Dynamic braking included for drives up to U2KN7K5S and U2KX7K5S
(3) Dynamic braking for drives U2KN11KS, U2KX11KS and larger is performed with external dynamic braking units
(4) No connection shell be made between RY0V and COM since this section is insulated
(5) Three COM terminals are internally connected

H.20
VAT2000
Notes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Multimode speed drives


. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H.21
VAT2000
I/O terminal board specifications
Control terminal board
Terminals Function Description
Digital inputs
RY0, RY24 Relay input common This is a common terminal for relay input signals specified below
PSI1 ~ PSI5 Programmable inputs These inputs can be arbitrarily set to any of input sequence functions
EMS Emergency stop If EMS is ON while the VAT2000 is stopped, all operational commands are cancelles. If it is ON
during operation, the VAT2000 is led into stopping sequence (ramp down stop or coast-to-stop
are available)
It is also possible to output this signal as a fault (FLT).
RESET Fault reset A faulty condotion is reset. With this signal, a fault status output (FLT LED, FAULT relay operation)
is turned OFF and operation becomes possible
Speed drive units

RUN Forward run This is a command for forward run. Run/Reverse mode by permanent or pulse command can be
selected
Analogue inputs FSV Voltage/Frequency This is mainly used for setting frequency (speed). The maximum speed setting is available at 10V
input. This input is valid when VFS function is ON.
FSI Current/Frequency This is mainly used for setting frequency (speed). The maximum speed setting is available at
20mA input. This input is valid when IFS function is ON.
AUX Auxiliary input This is mainly used for setting frequency (speed). The maximum speed setting is available at ±10V
input. This setting is valid when AUX function is ON.
COM Analogue input common This is a common terminal for FSV, FSI and AUX signals.
Analogue outputs FM Frequency meter This is a voltage output signal for a frequency meter. In a standard mode, a 10V output is
available at the maximum frequency. This output voltage can be adjusted to 0.2 to 2.0 times 10V
(max. output is, however, approximately 11V). Internal parameters other than those of frequency
can also be output (C13-0, C14-0)
AM Ammeter This is a voltage output signal for ammeter. In a standard arrangements, an output of 5V is
A available for the rated current. This output voltage adjustment of 0.2 to 2.0 times of 5V is also
available. Internal parameters other than those of current can also be output.
COM Analogue output This is a common terminal for a frequency meter and ammeter
common
B P10 FSV source This is a 10V source used when a potentiomenter is connected to the FSV input circuit
The potentiometer should be of 2W and 2k2Ω
Digital outputs RC, RA RUN Dry relay contact assigned to RUN function as default. Programmable to other functions as well
FC, FA, FB FAULT Dry relay contact assigned to FAULT function. It operates when a fault occur
PS01 READY Programmable open collector output assigned to READY function as default
C PS02 Current detection Programmable open collector output assigned to current detection function as default
PS03 Frequency speed Programmable open collector output assigned to speed detection as default attainment
PS0E Open collector This is a common terminals for the PS01, 2 and 3 outputs
output common All digital outputs can be set to any of output sequence functions
D

H.22
VAT2000

Input sequence functions


Terminals Function Description
R RUN Reverse run This is a command for reverse run
F JOG, R JOG Forward/Reverse jogging These are jogging commands. If this signal is ON while RUN is OFF, operation then conforms to
the setting of jogging (A00-1 or 3). For stopping, either ramp down stop or coast-stop is available
HOLD Hold This is a stop signal used when Forward/Reverse command is operated by push-buttons

Multimode speed drives


BRAKE DC brake DC brake can be operated with this signal
C SEL Ramp selection Accel./decel. ramp performance is switched over. ACCel./Decel. time 2 (B10-0, 1) is available with
ON, and Accel./Decel. time 1 (A01-0, 1) is available with OFF
I PASS Ratio interlock bypass Ratio interlock operation is bypassed
VFS Speed setting 1 Enables frequency (speed) setting from analog input FVS (C07-0)
IFS Speed setting 2 Enables frequency (speed) setting from analog input IFS (C07-1)
AUX Speed setting 3 Enables frequency (speed) setting from analog input AUX (C07-2)
PROG Program functions Used for multiple speed setting. Selection of up to 8 fixed speed (PROG0 ~ PROG7) is made
with S0 ~ S3, SE
CFS CPU setting Enables frequency (speed) setting for a serial port
S0 to S3, SE Program setting When PROG is ON, the program frequency (8 fixed speeds) (B11-0 up to 7) is enabled.
BCD or direct speed selection are allowed (B11-8)
FUP Frequency up Raises the output frequency or motor speed (A00-0, A00-2)
FDW Frequency down Decreases the output frequency or motor speed
BUP Bias up Raises the output frequency set through PROG function
BDW Bias down Decreases the output frequency set through PROG function
IVLM Bias ratio control Enables BUP or BDW functions
AUXDV Dual settings Enables secondary settings (dual motor operation)
PICK Pick-up While this signal is ON, pick-up operation is effected as soon as RUN or R RUN is ON
EXC
ACR
Pre-excitation
ACR
Allows pre-excitation, establishing flux in the motor without generating torque
Enables ACR operation
A
PCTL P control ASR control is changed from the PI control to the P control
COP CPU operation Enables command control from the serial port
LIM 1
LIM 2
Drive torque limiter The drive torque is limited by the analog input or serial transmission when enabled
Regenerative torque lim. The regenerative torque is limited by the analog input or serial transmission when enabled
B
CPASS Ramp bypass The ramp function is bypassed when CPASS is enabled
MCH Machine time constant Enables machine time constant compensation in ASR block
RF0
TRQB1
0 setting
Torque bias 1
The speed setting is changed to 0 rpm.
The torque bias input 1 is enabled
C
TRQB2 Torque bias 2 The torque bias input 2 is enabled
DROOP Drooping changeover Enables Drooping function (B13-5)
DEDB Dead band setting The dead band setting of ASR is enabled (B14-0)
D
Output sequence functions
RUN
FLT
Run
Fault
This turns ON during running, jogging or DC braking (C00-7)
This turns ON during a fault
E
MC Charge completed This turns ON when the DC main circuit voltage reaches right voltage level at power ON
RDY1 Ready (1) This turns ON when there is no fault, EMS is not activated, and pre-charging is completed
RDY2
LCL
Ready (2)
Local
This turns ON when there is no fault, EMS is activated and pre-charging is completed
This turns ON when the operation mode is local (operation from the operation panel)
F
REV Reverse run This turns ON while the motor is reverse running
IDET Current detection This turns ON when the output current reaches the detection level (C15-1) or higher
ATN Speed attainment This turns ON when the output frequency (speed) reaches the set frequency (speed) (C15-0)
SPD1 Speed detection (1) This turns ON when the output frequency (speed) reaches the speed set level (C15-2)
G
SPD2 Speed detection (2) This turns ON when the output frequency (speed) reaches the speed set level (C15-3)
COP CPU control This turns ON when serial transmission operation is selected
EC0~EC3 Fault code 0 to F After a fault this outputs the fault code with a 4-bit binary format
ACC Acceleration This turns ON during acceleration H
DCC Deceleration This turns ON during deceleration
AUXDV Dual selection This turns ON when the secondary drive parameter setting is validated
ALM Minor fault This turns ON during a minor fault
FAN Fan control This turns ON during running, jogging, pre-excitation and DC braking. A three minute off delay is I
provided, so even if the above operations turn OFF, this control will not turn OFF for three minutes.
This is used for external fan control
ASW Auto-start wait This is ON while Auto-start delay time (C08-0)
ZSP Zero speed This turns ON when the output frequency (speed) is below the level set with (C15-4) X
Remark: ON means contact is closed

H.23
VAT2000
Auto-tuning Soft Sound
The VAT2000 is performed with an Auto-tuning function VAT2000 Soft Sound technology reduces the characteristic
which simplifies the adjustment of critical control param- whine from inverter-driven motors and eliminates the
eters. The Automatic tuning can be performed in four mode side-effects of conventional noise reduction methods,
of operation, V/f Constant Torque, V/f Variable Torque, Vec- specifically that of raising the carrier frequency.
tor Sensorless, Full Vector with sensor. Soft Sound varies the carrier frequency in one of two fixed
patterns, from a user-selected base frequency (between
2.1kHz and 5kHz). By keeping the carrier frequency range
low, torque performance is notably better than
Auto-tuning procedure a high-frequency carrier.
The high frequency induced problems of hot running,
Speed drive units

Input inverter and motor ratings degrading of winding insularion, arcing across motor
bearings, high leakage currents, interference,.... These are
decreased by using Soft Sound carrier frequency.
Select the drive mode

Soft Sound
Run the drive
(run the tuning)

Auto-tuning error Auto


tuning

OK

A Error V/f or Vector related parameters


displayed are automatically set

B
Auto-tuning is complete

C
Drive and motor ratings Mono Sound
D B00/1-0 Input voltage (V)
B00/1-1 Motor rated output voltage (kW)
B00/1-2 Number of motor poles (Pole)

E B00/1-4
B00/1-5
Max. speed (min-1)
Base speed (min-1)
B00/1-6 Motor rated current (A)
B00/1-7 Carrier frequency
B01-8 Number of encoder pulses (P/R)
F

G Drive mode
C30-0 = 1 V/f Constant torque
C30-0 = 2 V/f Variable torque
C30-0 = 3 Vector sensorless
H C30-0 = 4 Full vector
C30-0 = 5 PM motor control

H.24
VAT2000
Vector control system. Speed block diagram
The VAT2000 performs an high-end Vector control system,
which allows speed accuracy up to 0.01% using encoder
feedback, and up to 0.5% in sensorless. The dynamic re-
sponse is excellent in all cases.
The speed control block diagram is given below

Multimode speed drives


Speed P control Torque Torque
setting gain limiter current

I control Current Speed


gain detection detection
Torque
Disturbance command
observer Detected motor
speed

Control
Corriente
Excitación Flux obser-
Estimated motor speed ver
&
Speed
Motor
speed
Sensorless
vector control
A
Vector control
with sensor
B

V/F Control. ATC system C


The VAT2000 includes an ATC (Advanced Torque Control)
function, which improves the starting torque in the
traditional V/F control systems allowing up to 200% torque D
with standard induction motors.
The Automatic tuning function set automatically drive
parameters, avoiding difficult manual adjustments.
The ATC block diagram is given below E
Automatic torque boost
selection
Slip compensation (A02-1) F
setting
(A02-5)

Overload limit Frequency


G
Set frequency
function command
Manual torque boost
selection
Manual torque boost (A02-0)
Voltage
H
setting
(A02-2) command

Square reduction torque


setting
I
(A02-3)

R1 drop compensation
setting
Automatic torque boost
selection
X
(A02-4) (A02-1)

Maximum torque boost


setting
(A02-6)

H.25
VAT2000
Ratio interlock function
This function allows full control ratio of speed setting and mo- limits, up/down speed setting increments and co-ordination
tor speed. Useful to synchronize several motors at different between two analogue inputs.
speed ratio. Ratio interlock setting function includes up/down

(C07-3) Upper/lower
Bias
Frequency
FSV, FSI, (speed) com-
PC serial Input mand
interface
Speed drive units

Bias
Coefficient increase/
(B06-0) decrease
buffer

Bias
(B06-1, 4)

PID Control
This function allows control of external conditions by using
a feedback signal. Useful for slow process control like water
pressure or flow, temperature by fans, etc
A
Pressure
sensor

B FSV or FSI
Pump

C12-4 (gain)

C
AUX / FSI

Aux: 0-10V, FSI:4-20mA


D Converter

E Multi-pump control
One pump is variable speed controlled and up to five order to ensure same average working time. As standard
F more controlled ON/OFF by the digital outputs provided
in the VAT2000. The water pressure in the pipe system is
the drive provide control up to 3 ON/OFF controlled pumps.
By using optional card U2KV23RY0, then operation is al-
controlled to be constant according the setting input in lowed up to 5 pumps.
the VAT2000’s PID. The pumps are automatically shifted in
G
Example of system configuration (when operating five ON/OFF control pumps)

H Pressure
setting Speed controlled
pump
ON / OFF pump 1
I ON / OFF pump 2
ON / OFF pump 3

X ON / OFF pump 4
Pressure transducer

ON / OFF pump 5

Converter

H.26
VAT2000

Pressure transducer
4-20mA

Main Pump 1 Pump 2 Pump 3


pump

Multimode speed drives


Control ON/OFF auxiliary pumps

Speed controlled pump

Operation and pump shift sequence

PID
output

PS01
pump 1 B
PS02
pump 2

PS03
(1) Pump with shortest time operation C
pump 3 (2) Pump with longest time operation
(3) Pump with longest time operation
PS04 (4) Changeover ignored as time is less
pump 4 than adjusted in timer T1
(5) Pump with longest time operation is
D
PS05
OFF if running time is over T2.
pump 5
A pump with shortest time
operation in ON

Stand-by status
(6) VAT2000 is stopped. Restart is E
automatically produced if PID leaves
LLT level

T1 = Hold time
T2 = Continuous operation time limit
F
PID T3 = Changeover time
output

Time H
PS01
pump 1

PS02
pump 2
I
PS03
pump 3
Operation Restart X
VAT2000

H.27
VAT2000
Pattern run
Up to ten steps automatic operation.
Useful for machines working in a repeated cycle.

Frequency (speed)
Time
Speed drive units

Step-0 Step-1 Step-2 Step-3 Step-4

RUN

Traverse
Usefull function for winding textil equipment. analog input setting, keypad setting or programmable
A The traverse centre frequency, can be selected from either fixed speeds.

F Retry
Allows automatic restart after a fault. Provides up to 10
G programmable retries with programmable time between
tries.
Output frequency

I Motor speed

Time
X
Internal
FLT

1 Waiting time after trip by Overcurrent,


2 3 Pick-up and retry
4 Pick-up achieved and retry finished

H.28
VAT2000
High efficiency operation (energy saving)
During V/f constant operation, the non-load loss is large
with motor unloaded or with a small load, and the motor
efficiency drops remarcably. Thus, this function
automatically decreases output voltage according to the
load, improving motor efficiency.
Sliping may increase during high-efficiency operation so

Multimode speed drives


is recommended to use the automatic slip compensation.
Autotuning will help for right adjustment.

Output voltage

Output voltage
V/F setting voltage 100%

Output voltage fluctuation


V/f setting 100% at frequency f
voltage
C25-1 setting (10-100%)

Lower limit of output voltage


C25-1 to be reduced
Reduced (10~100)
voltage
Time Frequency
f
C25-0
(0.1~30.0)
A
Frequency jumps
B
By this function, the motor’s mechanical resonance at a
specific frequency can be skipped.

Communications
C
Built-in with RS485 port and ASCII communication protocol.
Optional Profibus DP interface. D
Other communication interfaces in development.

Fault history E
The last four faults are coded and saved in a internal buffer.

H.29
VAT2000
External accessories

Power
supply
Stand-alone option

DBR
MCCB or unit
fuse

MC Noise
filter
Speed drive units

Main circuit
wiring

Absorber
Built-in PCB option

Stand-alone options
Noise filter U2KF-oooo This device supresses the elctro-
PR-oooo magnetic noise generated by the
A inverter. It may be required for EMC
compliance (CE)

B DBR unit U2KV23DBU-oo This module provides dynamic


braking capacity to drives
larger than 7.5kW (U2KN07K5S or
U2KX07K5S).
C Always install appropriate braking
resistor

If the line impedance is too low the


ACL
D ACR-oooo
current ripple trough input
rectifier become excessive and
may result in inverter damage.
This may happen when the power
E supply transformer exceeds 10
times the inverter unit capacity, so
always install reactors in this case.
Reactors are also effective
F improving the power factor and
suppressing the current high
harmonics. The power factor will
be approx. 0.9.
G
DCL DCR-oooo Same benefits than ACL reactors,
note however that ACL provides
additional protection to input
H rectifier

Surge absorber ACFR-oooo & This device protects the motor


I N11P34018 against surge voltage. It is
applicable to 400-460V systems,
and may be required if output
wiring to motor exceeds of 40m
X length.
The surge absorver is composed
by one output reactor and a RC
filter

H.30
VAT2000

Constant torque ratings


VAT2000 Losses Fuses MCCB Series EMC Dynamic braking Braking Input Surge absorber (4)
Cat. No W (A) (1) (A) (2) MC filter module resistor (3) AC reactor DC reactor Reactor + RC filter
U2KN00K4S 49 20 5 CL00 U2KF3016PR1 Built in VAT2000 TLR405P200 ACR4A2H5 - -
U2KN00K7S 62 20 5 CL00 U2KF3016PR1 Built in VAT2000 TLR216P200 ACR6A2H5 - -
U2KN01K5S 84 50 10 CL00 U2KF3016PR1 Built in VAT2000 TLR108P200 ACR9A1H3 - -
U2KN02K2S 117 60 15 CL00 U2KF3030PR1 Built in VAT2000 TLR74P200 ACR12A0H84 - -

Multimode speed drives


U2KN04K0S 153 110 20 CL01 U2KF3030PR1 Built in VAT2000 TLR44P600 ACR18A0H56 - -
U2KN05K5S 215 125 30 CL02 U2KF3060PR2 Built in VAT2000 TLR29P600 ACR27A0H37 DCR32A0H78 -
U2KN07K5S 301 225 40 CL04 U2KF3060PR2 Built in VAT2000 TLR22P600 ACR35A0H27 DCR45A0H55 -
U2KN11K0S 420 225 75 CL04 U2KF3094PR3 U2KV23DBUL1 TLR15P1000 ACR55A0H18 DCR60A0H4 -
U2KN15K0S 506 250 75 CL06 U2KF3094PR3 U2KV23DBUL1 TLR11P1200 ACR70A0H14 DCR80A0H3 -
U2KN18K5S 708 400 100 CL07 PR3120STD U2KV23DBUL1 TLR8,8P1500 ACR80A0H14 DCR100A0H24 -
U2KN22K0S 757 500 150 CL09 PR3120STD U2KV23DBUL2 TLR7,4P1800 ACR97A0H11 DCR120A0H2 -
U2KN30K0S 1192 500 150 CL10 PR3150STD U2KV23DBUL2 TLR5P2500 ACR140A0H072 DCR150A0H17 -
U2KN37K0S 1491 600 200 CK75 PR3180STD U2KV23DBUL3 TLR4P3000 ACR180A0H056 DCR180A0H14 -
U2KX00K4S 63 10 5 CL00 U2KF3016PR1 Built in VAT2000 TLR864P200 ACR3A8H1 - ACFR10A + N11P34018
U2KX00K7S 83 10 5 CL00 U2KF3016PR1 Built in VAT2000 TLR864P200 ACR3A8H1 - ACFR10A + N11P34018
U2KX01K5S 111 20 5 CL00 U2KF3016PR1 Built in VAT2000 TLR432P200 ACR4A5H1 - ACFR10A + N11P34018
U2KX02K2S 129 30 5 CL00 U2KF3016PR1 Built in VAT2000 TLR295P200 ACR6A3H4 - ACFR10A + N11P34018
U2KX04K0S 175 50 15 CL00 U2KF3016PR1 Built in VAT2000 TLR175P600 ACR10A2H - ACFR10A + N11P34018
U2KX05K5S 275 60 20 CL00 U2KF3032PR2 Built in VAT2000 TLR118P600 ACR14A1H4 DCR18A2H9 ACFR14A + N11P34018
U2KX07K5S 345 90 30 CL02 U2KF3032PR2 Built in VAT2000 TLR86P600 ACR18A1H1 DCR25A2H1 ACFR18A + N11P34018
U2KX11K0S 369 110 40 CL04 U2KF3058PR3 U2KV23DBUH1 TLR59P1000 ACR27A0H75 DCR32A1H6 ACFR27A + N11P34018
U2KX15K0S 481 125 40 CL04 U2KF3058PR3 U2KV23DBUH1 TLR43P1000 ACR35A0H58 DCR40A1H2 ACFR35A + N11P34018
U2KX18K5S 550 175 50 CL04 U2KF3058PR3 U2KV23DBUH1 TLR35P1500 ACR38A0H58 DCR50A0H96 ACFR38A + N11P34018
U2KX22K0S 675 225 50 CL06 U2KF3096PR4 U2KV23DBUH2 TLR29P1800 ACR45A0H45 DCR60A0H82 ACFR45A + N11P34018
U2KX30K0S 876 250 75 CL06 U2KF3096PR4 U2KV23DBUH2 TLR22P2500 ACR70A0H29 DCR80A0H58 ACFR62A + N11P34018
U2KX37K0S 945 300 100 CL07 PR3110STD U2KV23DBUH3 TLR18P3000 ACR90A0H22 DCR100A0H49 ACFR90A + N11P34018
U2KX45K0S 1175 400 100 CL09 PR3150STD U2KV23DBUH3 TLR15P3700 ACR115A0H18 DCR140A0H32 ACFR115A + N11P34018
U2KX55K0S 1558 400 150 CK75 PR3180STD U2KV23DBUH4 (5) ACR115A0H18 DCR140A0H32 ACFR115A + N11P34018 A
U2KX75K0S 2020 500 200 CK08 PR3280STD U2KV23DBUH4 (5) ACR160A0H14 DCR180A0H25 ACFR160A + N11P34018
U2KX90K0S 2509 700 300 CK85 PR3280STD U2KV23DBUH4 (5) ACR185A0H11 DCR210A0H25 ACFR185A + N11P34018
U2KX110KS 3343 800 300 CK09 PR3330STD U2KV23DBUH4 (5) ACR225A0H096 DCR270A0H18 ACFR225A + N11P34018
U2KX132KS 3906 800 350 CK09 PR3380STD U2KV23DBUH4 (5) ACR300A0H067 DCR310A0H14 ACFR300A + N11P34018
U2KX160KS 4915 1200 400 CK95 PR3450STD U2KV23DBUH4 (5) ACR360A0H056 DCR400A0H13 ACFR360A + N11P34018 B
U2KX200KS 6520 1600 500 CK10 PR3600STD U2KV23DBUH4 (5) ACR460A0H056 DCR540A0H08 ACFR460A + N11P34018
U2KX250KS 7848 200 700 CK11 PR3750STD 2 x U2KV23DBUH4 (5) ACR550A0H039 DCR650A0H07 ACFR550A + N11P34018
U2KX315KS 9026 2000 800 CK12 PR3900STD 2 x U2KV23DBUH4 (5) ACR625A0H035 DCR740A0H06 ACFR625A + N11P34018

Variable torque ratings C


VAT2000 Losses Fuses MCCB Series EMC Dynamic braking Braking Input Surge absorber (4)
Cat. No W (A) (1) (A) (2) MC filter module resistor (3) AC reactor DC reactor Reactor + RC filter
U2KN00K4S
U2KN00K7S
62
84
20
50
5 CL00 U2KF3016PR1 Built in VAT2000
10 CL00 U2KF3016PR1 Built in VAT2000
TLR405P200
TLR216P200
ACR6A2H5
ACR9A1H3
-
-
-
-
D
U2KN01K5S 117 60 15 CL00 U2KF3016PR1 Built in VAT2000 TLR108P200 ACR12A0H84 - -
U2KN02K2S 153 110 20 CL01 U2KF3030PR1 Built in VAT2000 TLR74P200 ACR18A0H56 - -
U2KN04K0S 215 125 30 CL02 U2KF3030PR1 Built in VAT2000 TLR44P600 ACR27A0H37 - -
U2KN05K5S 301 225
U2KN07K5S 420 225
40 CL04 U2KF3060PR2 Built in VAT2000
75 CL04 U2KF3060PR2 Built in VAT2000
TLR29P600
TLR22P600
ACR35A0H27
ACR55A0H18
DCR45A0H55
DCR60A0H4
-
-
E
U2KN11K0S 506 250 75 CL06 U2KF3094PR3 U2KV23DBUL1 TLR15P1000 ACR70A0H14 DCR80A0H3 -
U2KN15K0S 708 400 100 CL07 U2KF3094PR3 U2KV23DBUL1 TLR11P1200 ACR80A0H14 DCR100A0H24 -
U2KN18K5S 757 500 150 CL09 PR3120STD U2KV23DBUL2 TLR8,8P1500 ACR97A0H11 DCR120A0H2 -
U2KN22K0S 1032 500
U2KN30K0S 1341 600
150 CL10
200 CK75
PR3150STD
PR3150STD
U2KV23DBUL2
U2KV23DBUL3
TLR7,4P1800 ACR140A0H072 DCR150A0H17
TLR5P2500 ACR180A0H056 DCR180A0H14
-
-
F
U2KN37K0S 1657 600 200 CK75 PR3180STD U2KV23DBUL3 TLR4P3000 ACR200A0H051 DCR220A0H11 -
U2KX00K4S 83 10 5 CL00 U2KF3016PR1 Built in VAT2000 TLR864P200 ACR3A8H1 - ACFR10A + N11P34018
U2KX00K7S 111 20 5 CL00 U2KF3016PR1 Built in VAT2000 TLR864P200 ACR4A5H1 - ACFR10A + N11P34018
U2KX01K5S 129
U2KX02K2S 175
30
50
5 CL00 U2KF3016PR1 Built in VAT2000
15 CL00 U2KF3016PR1 Built in VAT2000
TLR432P200
TLR295P200
ACR6A3H4
ACR10A2H
-
-
ACFR10A + N11P34018
ACFR10A + N11P34018
G
U2KX04K0S 275 60 20 CL00 U2KF3016PR1 Built in VAT2000 TLR175P600 ACR14A1H4 - ACFR14A + N11P34018
U2KX05K5S 345 90 30 CL02 U2KF3032PR2 Built in VAT2000 TLR118P600 ACR18A1H1 DCR25A2H1 ACFR18A + N11P34018
U2KX07K5S 369 110 40 CL04 U2KF3032PR2 Built in VAT2000 TLR86P600 ACR27A0H75 DCR32A1H6 ACFR27A + N11P34018
U2KX11K0S 481 125
U2KX15K0S 550 175
40 CL04 U2KF3058PR3 U2KV23DBUH1
50 CL04 U2KF3058PR3 U2KV23DBUH1
TLR59P1000 ACR35A0H58
TLR43P1000 ACR38A0H58
DCR40A1H2
DCR50A0H96
ACFR35A + N11P34018
ACFR38A + N11P34018
H
U2KX18K5S 675 225 50 CL06 U2KF3058PR3 U2KV23DBUH2 TLR35P1500 ACR45A0H45 DCR60A0H82 ACFR45A + N11P34018
U2KX22K0S 876 250 75 CL06 U2KF3096PR4 U2KV23DBUH2 TLR29P1800 ACR70A0H29 DCR80A0H58 ACFR62A + N11P34018
U2KX30K0S 1080 300 100 CL07 U2KF3096PR4 U2KV23DBUH3 TLR22P2500 ACR90A0H22 DCR100A0H49 ACFR90A + N11P34018
U2KX37K0S 1104 400
U2KX45K0S 1437 400
100 CL09
150 CL09
PR3150STD
PR3180STD
U2KV23DBUH3
U2KV23DBUH4
TLR18P3000 ACR90A0H22 DCR125A0H40
TLR15P3700 ACR115A0H18 DCR140A0H32
ACFR90A + N11P34018
ACFR115A + N11P34018
I
U2KX55K0S 2091 500 200 CK75 PR3280STD U2KV23DBUH4 (5) ACR160A0H14 DCR180A0H25 ACFR160A + N11P34018
U2KX75K0S 2473 700 300 CK08 PR3280STD U2KV23DBUH4 (5) ACR185A0H11 DCR210A0H25 ACFR185A + N11P34018
U2KX90K0S 2998 800 300 CK85 PR3330STD U2KV23DBUH4 (5) ACR225A0H096 DCR270A0H18 ACFR300A + N11P34018
U2KX110KS 3758 800
U2KX132KS 4637 1200 400 CK09
350 CK09 PR3380STD
PR3450STD
U2KV23DBUH4
U2KV23DBUH4
(5)
(5)
ACR300A0H067 DCR310A0H14
ACR360A0H056 DCR400A0H13
ACFR300A + N11P34018
ACFR360A + N11P34018
X
U2KX160KS 5566 1600 500 CK95 PR3600STD U2KV23DBUH4 (5) ACR460A0H056 DCR540A0H08 ACFR460A + N11P34018
U2KX200KS 7266 2000 700 CK10 PR3750STD 2 x U2KV23DBUH4 (5) ACR550A0H039 DCR650A0H07 ACFR550A + N11P34018
U2KX250KS 8745 2000 800 CK11 PR3900STD 2 x U2KV23DBUH4 (5) ACR625A0H035 DCR740A0H06 ACFR625A + N11P34018
U2KX315KS 10061 2600 900 CK12 PR3900STD 2 x U2KV23DBUH4 (5) ACR700A0H035 DCR800A0H06 ACFR700A + N11P34018
(1) To comply with UL with VAT2000, 400 series, use a Class J fuse
(2) Use MCCB with magnetic trip only
(3) External braking resistors for 100% braking torque, 10% ED.
Drives up to U2KN07K5S y U2KX07K5S include a small built-in braking resistor. Check product manual for appropriate usage.
(4) Both output reactor and RC filter are required to absorb surge voltage which may be produced on motor side.
(5) Ask your distributor for accessories of drives above U2KX45__.

H.31
VAT2000
Dimensional drawings and weights

Multimode speed drives

Cat. no. Dimensions (mm) Main Weight


Supply Supply A B C D E Ød circuit (kg)
200-230V 380-460V terminal
N00K4 X00K4 170 243 162 155 228 6 M4 3.5
N00K7 X00K7 170 243 162 155 228 6 M4 3.5
N01K5 X01K5 170 243 162 155 228 6 M4 3.5
N02K2 X02K2 170 243 162 155 228 6 M4 3.5
Speed drive units

N04K0 X04K0 170 243 162 155 228 6 M4 3.5

Cat. no. Dimensions (mm) Main Weight


Supply Supply A B C D E Ød circuit (kg)

A 200-230V 380-460V
X05K5 216 275 169 201 260 7
terminal
M4 6
X07K5 216 275 169 201 260 7 M4 6
N05K5 216 275 169 201 260 7 M5 6
N07K5 216 275 169 201 260 7 M5 6
B X11K0
X15K0
265
265
360
360
228
228
245
245
340
340
7
7
M5
M5
13
13
X18K5 265 360 228 245 340 7 M5 13
N11K0 265 360 228 245 340 7 M6 13
N15K0 265 360 228 245 340 7 M6 13
C

E Cat. no. Dimensions (mm) Main Weight


Supply Supply A B C D E Ød circuit (kg)
200-230V 380-460V terminal

F N18K5
X22K0
X30K0
310
310
500
500
253
253
200
200
480
480
10
10
M6
M8
26
26
N22K0 310 500 253 200 480 10 M8 26
N30K0 342 590 307 200 570 10 M8 55
X37K0 342 590 307 200 570 10 M8 50
G N37K0
X45K0
342
342
590
590
307
307
200
200
570
570
10
10
M8
M8
60
50
X55K0 420 690 309 300 686 10 M10 55
X75K0 420 690 309 300 686 10 M10 60
X90K0 480 740 352 400 714 10 M10 65
H X110K
X132K
480
488
740
980
352
358
400
320
714
956
10
13
M10
M10
70
90

X160K 488 980 358 320 956 13 M10 100


X200K 680 1100 379 500 1070 15 M16 210
I X250K
X315K
870
870
1300
1300
379
379
600
600
1270
1270
15
15
M16
M16
300
300

H.32
VAT2000

EMC foot-print filters

Cat. No. Ref. no Current Dimensions (mm) Input Weight


(A) A B C D E M. terminal (kg)
U2KF3016PR1 167832 16 288 175 51 273 100 M5 10mm2 1.5
U2KF3030PR1 167833 30 288 175 51 273 100 M5 10mm2 1.5

Multimode speed drives


U2KF3032PR2 167834 32 320 221 51 305 150 M5 10mm2 1.9
U2KF3058PR3 167835 58 427 275 66 402 225 M5 25mm2 4.4
U2KF3060PR2 167836 60 320 221 51 305 150 M5 25mm2 2.6
U2KF309PRD3 167837 94 427 275 66 402 225 M5 35mm2 5.1
U2KF3096PR4 167838 96 575 312 67 549 200 M5 35mm2 6.1

A
EMC stand-alone filters
B
Cat. No. Ref. no Current Dimensions (mm) Input Weight
(A) A B C D E M. terminal (kg)
PR3110STD
PR3120STD
167978
167979
110
120
400
400
170
170
90
90
373
373
130
130
M6
M6
50mm2
50mm2
15
15
C
2
PR3150STD 167980 150 510 180 115 470 156 M8 95mm 17
2
PR3180STD 167981 180 510 180 115 470 156 M9 95mm 17
2
PR3280STD 167982 280 700 260 130 660 230 M8 150mm 37
PR3330STD
PR3380STD
167983
167984
330
380
790
790
300
300
150
150
600
600
280
280
M8
M8
Bar 25x6 48
Bar 25x6 50
D
PR3450STD 167985 450 790 300 150 600 280 M8 Bar 25x6 50
PR3600STD 167986 660 790 300 150 600 280 M8 Bar 30x8 80
PR3750STD 167987 750 680 430 215 450 400 M10 Bar 40x10 80
PR3900STD 167988 900 680 430 215 450 400 M10 Bar 40x10 90 E

H.33
VAT2000
External dynamic braking units

The VAT2000 includes a dynamic braking feature in drives up to


U2KN07K5S and U2KX07K5S as standard.
For larger drives the dynamic braking is performed by using the external
module U2KV23DBU.
Remark: For larger drives from U2KX45__, please ask your dealer.
Fig. 1 Fig. 2
131 133 Cat. No. Ref. no. Fig. Weight
80 129 145 209
(kg)
6

108 205

6
U2KV23DBUL1 168098 1 1,7
U2KV23DBUL2 168099 1 1,7
Speed drive units

U2KV23DBUL3 168100 1 1,7


U2KV23DBUH1 168084 1 1,7
U2KV23DBUH2 168085 1 1,7
U2KV23DBUH3 168086 1 1,7
198
186

198
180
U2KV23DBUH4 168083 2 3,5

Braking resistors
A A small capacity braking resistor is included in drives up to U2KN07K5S
and U2KX07K5S as standard. Check User’s Manual for appropriate usage.
The external braking optional resistors for 100% braking capacity, 10% ED
B Fig. 1
Resistors with terminals for
are shown in below table:

Cat. No. Ref. no. Fig. Dimensions (mm) Weight


C A B C D (kg)
TLR405P200 129867 1 195 65 210 60 0.6
TLR216P200 129868 1 195 65 210 60 0.6
TLR108P200 129869 1 195 65 210 60 0.6
D TLR74P200
TLR44P600
129870
129166
1
1
195
450
65
95
210
465
60
60
0.6
1.2
TLR29P600 129167 1 450 95 465 60 1.2
TLR22P600 129168 1 450 95 465 60 1.2
TLR15P1000 129169 1 450 100 465 70 1.8
E Fig. 2 TLR11P1200
TLR8,8P1500
129170
129171
1
2
450
440
120
100
465
460
75
140
2.4
2.2
Resistors with terminals for
TLR7,4P1800 129172 2 440 100 460 140 3.4
TLR5P2500 129871 2 440 180 460 140 3.2
TLR4P3000 129872 2 440 180 460 140 5.5
F TLR864P200
TLR432P200
129873
129875
1
1
195
195
65
65
210
210
60
60
0.6
0.6
TLR295P200 129876 1 195 65 210 60 0.6
TLR175P600 129173 1 450 95 465 60 1.2
TLR118P600 129174 1 450 95 465 60 1.2
G TLR86P600
TLR59P1000
129175
129176
1
1
450
450
95
100
465
465
60
70
1.2
1.8
TLR43P1000 129177 1 450 100 465 70 1.8
TLR35P1500 129877 2 440 100 460 140 2.2
TLR29P1800 129878 2 440 100 460 140 3.4
H TLR22P2500
TLR18P3000
129879
129880
2
2
440
440
180
180
460
460
140
140
3.2
5.5
TLR15P3700 129881 2 440 180 460 140 5.8

H.34
VAT2000
AC Input reactors

Fig. 1 Cat. No. Ref. no. Losses Fig. Dimensions (mm) Weight
(W) A B C D E Ø (kg)
ACR4A2H5 129978 9 1 137 146 103 125 102 7 2.9
ACR6A2H5 129979 11 1 137 146 103 125 102 7 3.2
ACR9A1H3 129980 14 1 137 146 113 125 102 7 4
ACR12A0H84 129981 19 1 173 167 118 146 127 7 8
ACR18A0H56 129982 21 1 173 167 133 146 127 7 10

Multimode speed drives


ACR27A0H37 129983 23 1 205 200 145 176 174 7 12
ACR35A0H27 129984 25 1 205 200 155 176 174 7 13
ACR55A0H18 129985 28 1 205 200 155 176 174 7 13
ACR70A0H14 129986 32 2 280 190 210 80 250 9 20
ACR80A0H14 129987 35 2 280 190 210 80 250 9 20
ACR97A0H11 129988 39 2 280 190 210 80 250 9 20
ACR140A0H072 129925 40 3 280 220 210 90 250 9 22
ACR180A0H056 129926 42 3 280 230 210 100 250 9 27
ACR200A0H051 129927 47 3 280 245 210 115 250 9 29
ACR3ABH1 129989 8 1 137 146 103 125 102 7 2.8
ACR4A5H1 129990 9 1 137 146 103 125 102 7 2.9
ACR6A3H4 129991 11 1 137 146 103 125 102 7 3.2
Fig. 2 ACR10A2H 129992 14 1 137 146 113 125 102 7 4
ACR14A1H4 129993 19 1 173 167 118 146 127 7 8
ACR18A1H1 129994 21 1 173 167 133 146 127 7 10
ACR27A0H75 129995 23 1 205 200 145 176 174 7 12
ACR35A0H58 129996 25 1 205 200 155 176 174 7 13
ACR38A0H58 129997 32 1 205 200 170 176 174 7 14
ACR45A0H45 129998 35 1 205 200 170 176 174 7 14
ACR70A0H29 129928 40 2 280 200 210 90 250 9 22
ACR90A0H22 129700 42 2 280 210 210 100 250 9 27
ACR115A0H18 129701 47 2 280 225 210 115 250 9 29
ACR160A0H14
ACR185A0H11
129702
129703
51
53
3
3
340
340
230
250
265
265
106
126
310
310
9
9
38
43
A
ACR225A0H096 129704 58 3 340 250 265 126 310 9 45
ACR300A0H067 129705 75 3 410 320 315 136 380 9 81
ACR360A0H056 129706 78 3 410 320 315 136 380 9 86
ACR460A0H056
ACR550A0H039
129707
129708
107
110
3
3
490
490
340
340
365
365
142
142
460
460
9
9
97
98
B
ACR625A0H035 129709 120 3 490 340 365 142 460 9 101
ACR700A0H035 168285 130 3 490 340 365 142 460 9 105
Fig. 3
C

H.35
VAT2000
DC Reactors

Fig. 4 Cat. No. Ref. no. Losses Fig. Dimensions (mm) Weight
(W) A B C D E Ø (kg)
DCR32A0H78 168371 13 4 150 200 145 176 102 7 7
DCR45A0H55 168372 13 4 150 200 145 176 102 7 7
DCR60A0H4 168373 14 4 150 200 155 176 102 7 8
DCR80A0H3 168374 17 4 150 200 170 176 102 7 9
DCR100A0H24 168375 17 4 150 200 170 176 102 7 9
DCR120A0H2 168376 17 5 190 200 215 90 160 9 15
DCR150A017 168377 21 5 190 210 215 100 160 9 17
DCR180A0H14 168378 26 5 240 200 265 96 210 9 21
DCR220AH11 168379 27 5 240 200 265 96 210 9 21
DCR18A2H9 168380 13 4 125 167 118 146 89 7 5
Speed drive units

DCR25A2H1 168381 14 4 125 167 118 146 89 7 5


DCR32A1H6 168382 15 4 125 167 133 146 89 7 6
DCR40A1H2 168383 17 4 125 167 133 146 89 7 6
DCR50A0H96 168384 16 4 150 200 145 176 102 7 7
DCR60A0H82 168385 17 4 150 200 155 176 102 7 8
DCR80A0H58 168386 21 4 150 200 170 176 102 7 9
DCR100A0H49 168286 23 4 150 200 170 176 102 7 9
DCR125A0H40 168287 27 5 190 200 215 90 160 9 15
DCR140A0H32 168288 29 5 190 200 215 90 160 9 15
Fig. 5 DCR180A0H25 168289 33 2 250 230 300 106 210 9 25
DCR210A0H25 168290 35 2 250 240 300 126 210 9 27
DCR270A0H18 168291 37 2 250 250 300 136 210 9 28
DCR310A0H14 168292 39 2 250 250 300 136 210 9 31
DCR400A0H13 168293 42 2 300 270 350 116 260 11 55
DCR540A0H08 168294 49 2 300 300 350 136 260 11 56
DCR650A0H07 168295 50 2 300 300 350 136 260 11 57
DCR740A0H06 168296 51 2 300 300 350 136 260 11 58
A DCR800A0H06 168297 52 2 300 300 350 136 260 11 60

H.36
VAT2000
Surge absorber
AC reactors
Cat. No. Ref. no. Losses Fig. Dimensions (mm) Weight
Fig. 1 (W) A B C D E Ø (kg)
ACFR10A 168471 9 1 137 146 103 125 102 7 2.9
ACFR14A 168472 14 1 137 146 113 125 102 7 4
ACFR18A 168473 18 1 173 167 120 146 127 7 9
ACFR27A 168474 19 1 173 167 120 146 127 7 9

Multimode speed drives


ACFR35A 168475 20 1 173 167 133 146 127 7 10
ACFR38A 168476 21 1 173 167 133 146 127 7 10
ACFR45A 168477 32 1 205 200 160 176 174 7 12
ACFR62A 168478 32 1 205 200 170 176 174 7 14
ACFR90A 168479 42 2 280 230 210 100 250 9 24
ACFR115A 168480 44 2 280 245 210 115 250 9 27
ACFR160A 168481 51 2 340 230 265 106 310 9 40
ACFR185A 168482 53 2 340 250 265 126 310 9 45
ACFR225A 168483 78 2 410 300 315 116 380 9 80
ACFR300A 168484 80 2 410 320 315 136 380 9 86
ACFR360A 168485 120 2 490 360 365 162 460 9 124
ACFR460A 168486 140 2 560 360 415 120 520 11 140
ACFR550A 168487 160 2 560 380 415 160 520 11 155
ACFR625A 168488 175 2 700 400 520 150 660 11 172
ACFR700A 168489 190 2 700 420 520 170 660 11 193
Fig. 2

RC Filter
D
Cat. No. Ref. no. Losses Max. carrier Dimens. Weight
(W) frequency D (kg)
N11P3401806 168260
N11P3401807 168261
1470
297
8
4
275
135
14
8
E
Dimensions in mm

H.37
AV300i
Adjustable frequency flux vector drive
The AV300i is an exceptional drive. A quick glance shows the sleek, ergonomic
design that makes it stand out from the crowd. Taking a closer look at the
AV300i shows the impressive performance and flexibility in a compact package
that suits your application. With innovative modes of operation like sensorless
flux vector control and scalar V/Hz, the AV300i is the perfect solution for any
Flux vect or drives

control system.

Features and Benefits


Speed drive units

• GE control system toolbox software


Combined configuration, trend recording, and operator interface.
• Start-up wizards and Self-tune screen
Quickens and simplifies start-up.
• Removable LCD back lit keypad
• Virtual keypad
Allows operators to control drive from PC screen as if using keypad on drive
itself.
Provides easy viewing and access.
• Graphic monitoring of drive variables
Expedites start-up and displays drive’s parameters and functions
• Open architecture
A Allows connection to communication protocols.
Integrates with PLCs and operator interfaces.
• Optional DGF programmable application card
Develop customized control functions and execution blocks
B
Performance
C - Wide range of I/O and communica-
tion bus interfaces
Easely link the drive to a push-
button operator station with a speed
D pot or an automated solution with
PLCs and HMIs.
- Advanced control
E Configurable function blocks
coordinate your process line.
- High performance regulators
Provide tension sectional control.
F - Connectibility to the RS-300
Regenerative source for
applications requiring common dc
bus, like a slitting line.
G - Win+Drive configuration
software and DGF card
Allow easy programming for
H advance applications and
sophisticated processes like a turret
winder or flying shear control.
- Universal approvals
I UL, cUL and CE cover applications
around the globe.

H.38
OK Relay
contact

Relay 2
contact

Analogue output 1
0V
Analogue output 2

External braking BU comm. output


unit (optional)

BU-
0V24
Reserved
Reserved
Digital input 1
Digital input 2
Digital input 3
Digital input 4
Digital output 1
Digital output 2
Supply DO
R1K
Motor PTC

Analogue input
1
Analogue input
2
Analogue input
3
option
lighting

+10V
-10V
0V
Enable drive
viewing and access.

Start
Fast stop
External fault
COMD I/O
Adjustable keypad tilts for easy

0V24
you need it with the remote cable

+24V OUT
Locate the removable keypad where
2 line x 16 character display with back
AV300i

AV300i

H.39
I
F
E

X
B
A

Flux vector drives


D

H
AV300i

Control system toolbox


With its PC-based configuration and control, the AV300i is Benefits
easy to set up, easy to run and easy to monitor. - Start-up wizards
The AV300i is configured by the GE Control System - Combination of configuration, trend recording and
Toolbox(1), an intuitive control system that utilizes operator interface
configuration wizards, animated block diagrams and an - Real time picture of signal flow.
Flux vect or drives

integrated trend window to save valuable time in Sequencing and regulator control provided by animated
commissioning. “Toolbox” provides customizable controls block diagrams
for real-time monitoring and operation right from the PC - Standard «drag and drop» techniques.
screen. And the AV300i drive works with a wide variety of Allow any block diagram value to be copied to the trend
popular communication buses, PLCs and HMIs. recorder for real-time monitoring and historical trending.
Speed drive units

- Online drive parameter controls.


Drive can be checked and modified online directly from
the “Toolbox”.
- Various drive configurations.
Can be stored for future downloads.
- Virtual reality keypad.
Allows operators to control the drive directly from the PC
screen programming tool, also works with GE products
(like DV300, RS300 and others).
(1) - A RS485/232 converter (6KCV300CTI) and communication cable - Online help.
(6KCV8S8F59) is required for communication between AV300i and Puts answers at operator’s fingertips and are available
the PC.
- A CD-Rom containing the GE Toolbox software is delivered with at any time and any point during the set-up, start-up, or
A each drive. operation of the drive.

B Regulator block diagrams Real time values are


show signal flow displayed

G
Point and click to get
H Current status of I/O is
displayed
more detailed views

H.40

32764_H38_H43_E.indd 40 13-07-2005 09:47:28


AV300i

Open architecture
Our open architecture offers the ability to connect to
popular communications protocols like DeviceNet, Genius,
Profibus, IS Bus and Interbus-S. This drive easily integrates
with popular PLCs and Operator Interfaces. With the
addition of a DGF programmable application card, you can
develop customized control functions and execution blocks
that can be directly incorporated into the AV300i’s
configuration. With our WIN+DRIVE graphical program
editor, you have pre-designed code and library of building
blocks so you can «drag-and-drop» and “point-and-click”

Flux vector drives


to make the DGF card your application solution. Predevel-
oped programs such as winder control and electric line
shaft are also available.

AV300i
And, the AV300i’s architecture knows no boundaries. The
drives comes UL, cUL and CE labeled so it has the agency
approvals needed around the globe. The AV300i opens up
your architecture. The compact design fits into packed
control cabinets. Up to 15kW/20hp, the drive can mount
Genius and
«bookshelf» style so space is not wasted due to clearance
GE ISBus
requirements for heating.
(not shown)

Profibus-DP
A

DeviceNet C

DGF Card
D

E
Analogue and
digital expansion

F
Digital Input/
Output
expansion
G
Encoder
expansion
H
Analogue and
digital expansion I
with encoder

H.41
AV300i
Adjustable frequency flux vector drives
Rated current Recommended motor output
Cat. no. Ref. no.
Class 1 Class 2 Class 1 Class 2
no overload 150% overload no overload 150% overload

ULN = 400V ULN = 460V ULN = 400V ULN = 460V ULN = 230V ULN = 400V ULN = 460V ULN = 230V ULN = 400V ULN = 460V
(A) (A) (A) (A) (kW) (kW) (HP) (kW) (kW) (HP)
2.4 2.1 2.2 1.9 - 0.75 1 - 0.75 0.75 6KAVI43F75Y1 _ _ 414250
4 3.5 3.6 3.2 - 1.5 2 - 1.5 1.5 6KAVI43001Y1 _ _ 414251
5.6 4.9 5.1 4.4 - 2.2 3 - 2.2 2 6KAVI43002Y1 _ _ 414252
7.5 6.5 6.8 5.9 - 3 3 - 3 3 6KAVI43003Y1 _ _ 414253
9.6 8.3 8.7 7.6 - 4 5 - 4 5 6KAVI43005Y1 _ _ 414254
12.6 12 11.5 11 - 5.5 7.5 - 5.5 7.5 6KAVI43007Y1 _ _ 414255
17.7 15.4 16.1 14 - 7.5 10 - 7.5 10 6KAVI43010Y1 _ _ 414256
24.8 23.1 22.5 21 - 11 15 - 11 15 6KAVI43015Y1 _ _ 414257
Speed drive units

33 29.7 30 27 - 15 20 - 15 20 6KAVI43020Y1 _ _ 414258


47 40 43 36 11 22 30 11 22 25 6KAVI43025X1 _ _ 414264
47 40 43 36 11 22 30 11 22 25 6KAVI43025Y1 _ _ 414259
63 54 58 50 18.5 30 40 15 30 30 6KAVI43030X1 _ _ 414265
63 54 58 50 18.5 30 40 15 30 30 6KAVI43030Y1 _ _ 414260
79 68 72 62 22 37 50 18.5 37 40 6KAVI43040X1 _ _ 414266
79 68 72 62 22 37 50 18.5 37 40 6KAVI43040Y1 _ _ 414261
93 81 85 74 22 45 60 22 45 50 6KAVI43050X1 _ _ 414267
93 81 85 74 22 45 60 22 45 50 6KAVI43050Y1 _ _ 414262
114 99 104 90 30 55 75 30 55 60 6KAVI43060X1 _ _ 414268
114 99 104 90 30 55 75 30 55 60 6KAVI43060Y1 _ _ 414263
142 124 129 112 37 75 100 37 55 75 6KAVI43075X1 _ _ 414269
185 160 169 146 55 90 125 45 90 100 6KAVI43100X1 _ _ 414270
210 183 191 166 55 110 150 55 90 125 6KAVI43125X1 _ _ 414271
250 217 227 198 75 132 150 55 110 150 6KAVI43150X1 _ _ 414272
324 282 295 256 90 160 200 90 160 200 6KAVI43200X1 _ _ 414273

A Remarks - AV330i with full function keypad is the standard configuration of the drive.
- Drives up to 6KAVI43020always include Dynamic braking.
- For ambient temperature abbove 40ºC, derate current by 2% per 1ºC. Max. temperature at all is 50ºC
- For carrier frequency higher than default, derate current by 30%. Check specifications
B

Catalogue number structure


C Drive Enclosure
AV300i rating (1 = IP20)

D 6KAVI 4 3 003 Y 1 _ _
Revision
code

3ph for
E input
Main drive
option
voltage X = Full keypad without dynamic braking
Y = Full keypad with dynamic braking
M = No keypad (Led module) without dynamic braking
F N = No keypad (Led module) with dynamic braking

H Options Digital I/O expansion 8DI (24VDC), 4DO (Relays) 6KCV301D8R4 414333
I/O expansion 8DI, 6DO, 2AI, 2AO, 1 ENC +5V, 15-24V 6KCV301D14A4 414334
I/O expansion 12DI, 8DO, 2AI, 2AO-V, 2AO-I 6KCV301D20A6 414335
Encoder input and repeater (5VDC, 15-30VDC) 6KCV301ENC 414158
I Programmable application controller
Communication option Profibus DP
6KCV301DGF
6KCV301PDP33
414343
414066
Communication option DeviceNet 6KCV301DNET 414352
Communication option Genius HE300GEN250 414353

X External options External brake unit (20A)


External brake unit (50A)
6KBU-300-20
6KBU-300-50
414460
414141
External brake unit (85A) 6KBU-300-85 414095
RS232/RS485 converter 6KCV300CTI 414038
Cable for RS232/RS485 converter 6KCV8S8F59 414371
Keypad mounting kit 6KCV301KPDMK 414332

H.42
AV300i
Filters and external dynamic braking
Drive Losses EMC filter External dynamic
(1) (400 VAC) braking module
Source up to 440V Source up to 440-480V
W Cat. no. Ref. no. Cat. no. Ref. no. Cat. no.
6KAVI43F75 48.2 EMI-FFP 480-9 414381 COMP 520-7 414397 -
6KAVI43001 77.5 EMI-FFP 480-9 414381 COMP 520-7 414397 -
6KAVI43002 104 EMI-FFP 480-9 414381 COMP 520-7 414397 -
6KAVI43003 138.3 EMI-FFP 480-9 414381 COMP 520-7 414397 -
6KAVI43005 179.5 EMI-FFP 480-24 414382 COMP 520-16 414398 -
6KAVI43007 233.6 EMI-FFP 480-24 414382 COMP 520-16 414398 -
6KAVI43010 327.4 EMI-FFP 480-24 414382 COMP 520-30 414399 -
6KAVI43015 373 EMI-FFP 480-30 414383 COMP 520-30 414399 -
6KAVI43020 512 EMI-FFP 480-40 414384 COMP 520-30 414399 -

Flux vector drives


6KAVI43025 658 COMP 480-42 414385 COMP 520-30 414399 6KBU300-50 (2)
6KAVI43030 864 COMP 480-55 414386 COMP 520-42 414400 6KBU300-50 (2)
6KAVI43040 1100 COMP 480-75 414387 COMP 520-55 414401 6KBU300-50 (2)
6KAVI43050 1250 COMP 480-100 414388 COMP 520-75 414402 6KBU300-50 (2)
6KAVI43060 1580 COMP 480-100 414388 COMP 520-100 414403 6KBU300-85 (2)
6KAVI43075 1950 COMP 480-130 414389 COMP 520-100 414403 6KBU300-85 (3)
6KAVI43100 2440 COMP 480-180 414390 COMP 520-130 414404 2x 6KBU300-50 (3)
6KAVI43125 2850 RANGER 520-280 414391 COMP 520-180 414405 2x 6KBU300-85 (3)
6KAVI43150 3400 RANGER 520-280 414391 RANGER 520-280 414391 2x 6KBU300-85 (3)
6KAVI43200 4400 RANGER 520-450 414392 RANGER 520-280 414391 2x 6KBU300-85 (3)

(1) Drives types 6KAVI43___Y1__, from size 43F75 to 43060, include dynamic braking unit into the drive.
(2) These external braking units should be used to have dynamic braking performance in drives which are not fitted
with internal braking unit, types 6KAVI43___X1__, from size 43025 to 43060.
(3) Drives above 43060, always use external braking module when this function is required.

Remark: External braking units or drives «Y» option, do not include dynamic braking resistor.
Ask your dealer for this. A

H.43
AV300i
Technical data
General specifications
Item Description
Nominal motor power 230V, 3 phases 11 to 90kW
400V, 3 phases 0.75 to 160kW
460V, 3 phases 3/4 to 200HP
Enclosure Standard IP20
Cooling method Self power Up to 45 kW
External power From 55kW requires 115/230VAC, 50/60Hz external power supply
Standards CE marking / UL / cUL
Braking torque 0,75 to 15kW Braking module built-in as standard (needs external resistor)
18,5 to 55kW Optional external modules available and units with internal modules available (need external resistor)
Speed drive units

>= 75kW Optional external braking module available (BU300)

Input
AC voltage 230VAC / 400VAC / 460 VAC (+/-15%, 50/60Hz)
AC input frequency 50/60Hz, +/-5%
Unbalance 3% max. per EN 61800-3 standard
Power dip. For input voltage greater than Vmin., the drive will operate at rated output continuously
For input voltage less than Vmin. the drive will discontinue firing and control power will remain for a time
depending upon output current load and inverter size ranging from 0.25 sec. for 3/4 HP to 18 sec. for 200 HP

Ambient conditions
Altitude 1000 meters or less. Derate at 1,2% for each 100 meters from 1000 to 3000 meters (above 3000 meters,
please consult)
Temperature Ambient Option a: -10 to +50ºC (units less than and equal to 30HP must have ventilation covers removed for 50ºC).
A Derate current by 20%
Option b: -10 to +40ºC (up to 50ºC with ventilation cover removed). Over 40ºC derate current by 2% per 1ºC
Storage -20 to +55ºC
Vibration 1K4 of EN 50178
B Humidity 5 - 85% relative humidity (without condensation)

Output
230VAC, 3 phases 3 phase 200V at 50Hz or 3 phase 200V, 220V, 230V at 60Hz
C 460VAC, 3 phases 3 phase 380V, 400V, 415V, 440V at 50Hz or 3 phase 380V, 400V, 440V, 460V, 480V at 60Hz
(output voltage can not be higher than input voltage)
Frequency 50/60Hz nominal
Overload 150% of rated current for 1 min.; 200% for 0,5 sec. short term overload
D Max. frequency 400Hz, from 0.75 kW to 37 kW; 200Hz, from 45 kW and over
Carrier frequency Up to 37 kW, 8kHz as standard. Optional 16kHz with 30% current derating
From 45kW, 4kHz as standard. Optional 8kHz with 30% current derating

E Control
Control method Sinusoidal PWM V/Hz
Sensorless vector, Field oriented vector with digital tachomenter, Field oriented vector with sinusoidal encoder
Operation Methods Keypad, Digital inputs, Bus communication
F Reference setting Keypad Increase or decrease speed or enter speed setpoints
Potentiometer 1 - 10 kΩ (optional)
Analog -10VDC to +10VDC, 0-10VDC, 4-20mA, 0-20mA
Digital Inc./Dec. control (increases with UP, decreases with DOWN). 8 preset speed setpoints
G Configuration tool
Networks
RS485 standard
Optional network cards
Acceleration setting Four settings 0,0 - 65.535 seconds independent Acc./Dec. selectable Linear or S-curve (with adjustable S times)
Ramp control Programmable fast stop, Freeze ramp, Ramp delay, Ramp control

H Speed limiter
Auto-restart
High and low values are presettable
Programmable. Up to 99 restarts is available
PID control Generic process controller for speed regulator with dancer control, pressure, load cells and winders
Jog Selectable with or without ramp for keypad, terminals or bus communication
Tach follower Use the encoder input as a speed reference
I Analog control Map the analog inputs for speed, current or PID reference control
Speed ratio A scalar multiplier of speed reference after the ramps for co-ordinated lines
Drop Slow drive speed as a percentage of load or external signal for load sharing
Speed up Adjust the speed feedback for high inertia applications
X Inertia comp./ Inertia compensation and loss compensation for high performance process applications
Loss comp.
Ramp 1 & 2 Two inputs for speed reference before the ramp(s)
Speed ref. 1 & 2 Two inputs for speed reference after the ramps(s)
Speed zero logic Adjustable zero speed detection and time delay
Dimension factor Calibrate the drive speed reference to units other than RPM
Motor autotune Speed tuning Rotates motor on unsconstrained load and tunes speed regulator
Vector tuning Tunes current regulator without motor rotation; Flux and voltage regulators are selectable with
or without rotation

H.44
J.44
AV300i

Control (continued)
Item Description
Other control Test generator Square wave generator with user configurable offset, freq., and amplitude for regulator extra fine tuning
features DC braking Configurable
2nd motor parameters Selection of a 2nd set of motor parameters for using the drive with 2 different motors
Stop control User configurable sequencing of the drive using enable and start inputs
Power loss stop paramet. During a power loss, use the motor energy to regenerate the DC bus and bring the motor to an orderly stop
Links Generic scaling blocks for user signal manipulation
PAD parameters Virtual I/O for mapping drive I/O to the LAN, DGF or links

Regulators

Flux vector drives


General speed Speed zero gains Separate zero speed regulator gains
regulation control Adaptive speed gains Speed regulator gains settable by a profile.
The profile can be adjusted based on speed or another analog signal
Enable speed regulator Speed regulator can be disabled
Torque regul. control Torque control Output torque or load can be controlled by analog input signal, LAN, or appl. card
PID PID outer loop speed with dancer control, load cells and winders
Zero torque Command for zero output torque (note: not zero current)
Torque limits Torque current limits can be controlled by analog input signal, LAN or appl. card
Flux regulation control Constant current For operation up to rated motor speed
Voltage control For operation above rated motor speed
Output voltage level Manual or automatic adjustment or flux level above rated speed
Flux regulator gains User tunable voltage regulator gains
Voltage regulator gains User tunable flux regulator gains
V/Hz regulator Resolution 0.001Hz at 50Hz, 0.005Hz at 300Hz
Accuracy 0.3 times nominal motor slip A
Control range 1:50 (it depends of rated motor slip)
Slip compensation For speed compensation dependent upon load
Manual voltage boost Adjust boost via a parameter
Auto voltage boost
V/f shape
Boost is selected automatically from motor parameters
V/Hz relationship can be set to linear or three other non-linear models
B
Energy save Reduces losses at light loads
Catch A spinning Smoothly pick up a rotating motor without stopping and without DB
Sensorless vector Resolution
Accuracy
0.002 x nominal speed (spd ref. resolution = 0.25 rpm)
0.3% at nominal speed (1.3% at 2 x nominal speed)
C
Control range 1:50 at 2.5 x nominal speed
Max. bandwidth 100 rad/sec. 15.9Hz
Torque reg. resolution 1:1.000 (rpm)
Torque reg. accuracy Typically 5%, using rotor resistance adaptation
D
Torque control range 1:20
Torque min.response time 0.8ms
Torque max. bandwidth 2.4 krad/sec. 380Hz
Rotor resistance adaptat. Compensates for changes in rotor resistance due to heating E
Low speed factor Adjusts drive output to increase torque at low speeds (<2%)
Sensorless speed filter Adjusts speed feedback on light load applications
Flux correction factor Adjust estimated rotor flux on high inertia or regen. loads
Distortion load compens. Adjust current regulation for voltage distorsions F
Field oriented vector Resolution 0,5 rpm (spd ref. resolution = 0.25 rpm)
(digital tach) Accuracy Typical 0.02%
Control range > 1:1.000
Max. bandwidth 300 rad/sec, 47Hz G
Torque reg. resolution 1:1.000
Torque reg. accuracy Typically 5%, using rotor resistance adaptation
Torque control range 1:20
Torque min. response time 0.8 ms.
Torque max. bandwidth 2.4 krad/sec, 380Hz
H
Lock zero position Holds the position of the shaft at zerospeed
Index storing The C (index or marker) channel of the encoder can be used to accumulate pulses for positioning controls
Field oriented vector
(sinusoidal encoder)
Resolution
Accuracy
0.25 rpm (PPR>1.900), >0.25 (PPR < 1.900) (spd ref. resolution = 0.25 rpm)
Typically 0,01%
I
Control range > 1:10.000
Max. bandwidth 300 rad/sec., 47Hz
Torque reg. resolution 1:1.000
Torque reg. accuracy Typically 5%, using rotor resistance adaptation X
Torque control range s
Torque min. response time 0,8 ms.
Torque max. bandwidth 2,4 krad/sec, 380Hz
Lock zero position Holds the position of the shaft at zerospeed
Index storing The C (index or marker) channel of the encoder can be used to accumulate count for positioning controls

H.45
J.45
AV300i
Technical data (continued)

Keypad
Item Description
Adjustable viewing angle for optimal viewing
Backlit LCD display
Tactile keys for start, stop, increase speed, decrease speed, jog, menu navigation, alarm reset

Indication
Operating mode LCD Speed, Voltage, Current, Encoder, Power output, Torque, Motor flux, Frequency,
Ramp references, Speed references,
Speed drive units

Torque references, PID output, Heatsink temperature, Regulator card temperature, Overload time status,
Braking overload status, I/O status
Selections Programmable in %, or user selectable units
Configuration mode Parameters fully programmable while drive is not running
Tuning and control parameters are adjustable while running
Trip mode Undervoltage Selectable latched or unlatched fault DC link undervoltage
Overvoltage Selectable latched or unlatched fault DC link overvoltage
Overcurrent Selectable latched or unlatched fault
Heatsink sensor Heatsink temperature greater than preset temperature for over 10 seconds; fault can be latched or unlatched
Hetasink overtemp. Heatsink temperature greater than preset temperature fo over 1 second (25 to 200 Hp)
Regulation OT Regulation card temperature greater than preset temperature for over 10 seconds;
fault can be latched or unlatched
Module OT IGBT module overtemperature (0,75 to 15kW)
Motor overtemperature Motor overtemperature temperature, user selects action: warning, drive disable, quick stop, stop, curr. limit stop
BU overload Braking unit calculated overload, user selects action: warning, drive disable, quick stop, stop, curr. limit stop
A Speed fdk loss Loss of speed feedback. Fault can be enables or disabled
Output stages Shortcircuit detected in motor output or braking unit, disable drive. Fault can be latched or unlatched
Opt 2 DGF card error. User selects action: warning, drive disable, quick stop, stop, current limit stop
Hw Opt1 failure Option card error. User selects action: warning, drive disable, quick stop, stop, current limit stop
B Bus loss Loss of LAN communication. User selects action: warning, drive disable, quick stop, stop, current limit stop
External fault External fault input open. User selects action: warning, drive disable, quick stop, stop, current limit stop
Enable seq. error Drive powered up with enable input on. Fault can be turned off for auto restart
Faults Failure supply 24VDC power supply failure
C Cur fdk loss
DSP error
Loss of internal current feedback
Processor failure
Diagnostics History Trip history - past ten events (trip and warning) with relative time stamp

D
Protections
Overload Electronic overload automatically reduces current limit
Overvoltage Detection of DC link circuit overvoltage (400VDC - series 230VAC and 800VDC - series 460AC)
E Incoming surge Inverter protection from surge voltage input (max. 1.2kV x 50 µsec, 7kV peak)
Undervoltage Detection of DC link circuit undervoltage (200VDC - series 230VAC and 400VDC - series 460VAC)
Overheating Inverter overheating protection by temperature detection
Shortcircuit Shortcircuit protection for inverter output circuit
F Motor overload Electronic thermal overlay relay control
Calculation of thermal time constant can be preset
DB resistor overheating Internal electronic thermal overload relay control
Motor overheating Overheating detection thermistor input

G Signal loss detection of loss of analog input 1 when used as 4-20mA input

Terminal functions. Main circuit


Power input U1/L1, V1/L2, W1/L3 Three phase power source connections

H Inverter output
DC input/output
U2/T1, V2/T2, W2/T3
C, D
Three phase induction motor connections
Access to the DC link for common DC bus, or external DB modules
Braking unit C (+), BR1 (-) Connections for the braking resistor 0,75 to 15kW ( from 22 to 55kW when ordered this option)
Ground PE1 Ground terminal for inverter chassis (housing)
Communications port RS485 RS485 multidrop communication port for PC tools
I Standard connector Connection is through the standard DB9 pin connector

H.46
J.46
AV300i
Terminal functions. Inputs and Outputs
Item Description
Differential analog Ratings + /- 10VDC power supply, maximum allowable output current 10mA
inputs Selections -10VDC to +10VDC, 0-10VDC, 4-20mA, 0-20mA
Three configurable Resolution 11 bits + sign
Linearity 0,1% of full scale
Update rate 2msec. update
Adjustments Automatically adjust the scalings of the analog inputs
Software adjustable gains and offsets
Polarity can be selected by parameter or digital input
Enable or disable from digital input
Input 1 has an adjustable filter and comparator for 4-20mA signal loss detection
Parameters Jog reference, ramp references, speed references, outer loop inputs, current references, speed gain adjusts,

Flux vector drives


current limit adjusts, droop adjusts, PID adjustments, flux adjust, and speed ratio (draw)
Digital inputs Ratings 24VDC power (129 mA max.) and common for user
Four configurable Each input accepts 15-30VDC. Input power = 5mA at 24VDC per input
Update rate 8ms.
Adjustments Separate common for predefined digital inputs
Enable, start, fast stop, and external fault inputs
Separate power and common inputs for user digital inputs
Parameters Inc/dec. speed control, jog, reset, reduce torque, set ramp = 0, freeze ramp, lock speed regulator,
lock spd. reg. i ntegrator, enable,
«catch a spinning motor», analog in polarity, select speed setpoints, select ramps, speed fdk select, virtual I/O,
fwd/rev, disable analog ins., enable droop, quick stop
Digital outputs Ratings 24VDC power and common for user power supply and common
Two configurable terminals same as the for the digital inputs
20mA maximum current output, 15-30VDC out
Update rate 8ms.
Parameters Speed zero, speed threshold (up to speed), curr limit flag, drive ready, not in overload, ramp+, ramp-, speed in A
limit, undervoltage, overvoltage, heatsink OT (3), external fault, motor OT, power supply failure, output from
virtual I/O, speed fdk loss, bus loss, output stages, opt 1 failure, DGF failure, encoder loss, overload flag,
enable seq err, braking unit overload, diameter calc status, motor setup in use, 4-20mA signal OK,
overload >200%, power loss stop active, power loss time out regulation OT B
Differential analog Range +/- 10VDC, 5mA
outputs Resolution 11 bits + sign
Two configurable Update rate 2 ms
Adjustments Software adjustable gains C
Parameters Ramp reference 1&2, Speed references, Torque reference, PID output, Voltage, Current, Active power, Output
torque, Motor flux, Frequency
Relay outputs Drive OK relay NO contact opens on drive fault

Programmable relay
Rated 250VAC, 1A - AC11
Programmable NO contact
D
Rated 250VAC, 1A - AC11
Default is zero speed; see digital outputs a list of other programmable outputs
Encoder input Connection
P.P.R.
DB 15 pin hi density connector
600 P.P.R. minimum, maximum 9.999 P.P.R.
E
Frecuency Maximum 150kHz digital tach, 80kHz for a sinusoidal encoder
Power 5VDC, 200mA maximum with software level adjustment for long lead compensation
Types 5VDC, 2 channel differential sinusoidal encoder
5VDC, differential quadrature encoder with marker channel F
5VDC, 2 channel incremental sinusoidal encoder with 2 sin/cos traces

Options
Networks HE300GEN250 GENIUS G
6KCV301PDP33 Profibus DP
6KCV301DNET DeviceNet
Additional I/O 6KCV301D8R4 24VDC - 8 digital ins, 4NO contacts out
6KCV301D14A4 24VDC - 8 digital ins, 6 digital outs, 2ea 10V analog in, 2ea 10V analog outs, 1 encoder out H
6KCV301D20A6 24VDC - 12 digital ins, 8 digital outs, 2ea analog in (V or mA), 2ea 10V analog outs, 2ea mA outs
6KCV301ENC Encoder input & repeater 5V, 15V-30V input setting requires exteernal power supply
Application 6KCV301DGF DGF programmable application card
Braking module 6KBU300 _ _ Dynamic braking modules with ratings of 20A, 50A and 85A available I
Regenerative source RS300 Four quadrant operation with ratings of 185A, 280A, 420A, 650A, 1050A for 3ph 400-480VAC mains supply

H.47
J.47
AV300i
Plug-in terminal strip assignement
Connector X1 Function Maximum
Programmable/configurable analog differential input.
1 Analogue
Signal: terminal 1; Reference point: terminal 2
input 1 +/-10V
2 Default setting: Ramp ref. 1
at 0,25mA
3 Programmable/configurable analog differential input.
Analogue
Signal: terminal 3; Reference point: terminal 4 (20mA when
input 2
4 Default setting: none current ref. input)

5 Programmable/configurable analog differential input.


Analogue
Signal: terminal 5; Reference point: terminal 6
input 3
6 Default setting: none
Speed drive units

7 +10V Reference voltage +10V; Reference point: terminal 9 +10V/10mA

8 -10V Reference voltage -10V; Reference point: terminal 9 -10V/10mA

9 0V Internal 0V and reference point for +/-10V -

12 Enable drive Drive enable: 0V or open; drive disabled; +15...+30V : Drive enabled +30V

13 Start Drive start command: 0V or opne: No start; +15...+30V = Start 3.2mA at 15V

14 Fast stop 0V or open: Fast stop; +15 ... +30V; No Fast stop 5mA at 24V

15 External fault 0V or open: External fault; +15 ... +30V; No External fault 6.4mA at 30V

16 COMD I/O Reference point for digital inputs and outputs, term. 12...15, 36...39, 41...42 -

18 0V24 Reference point for +24V OUT supply, terminal 19 -


A 19 +24V OUT +24V supply output. Reference point: terminal 18 or 27 or 28
+22...28V
120mA at 24V

B 21 Analogue output 1 Program. analogue output; def. setting: Motor speed. Ref. point: term. 22 +/- 10V/5mA

22 0V Internal 0V and reference point for terminals 21 and 23 -

C 23 Analogue output 2Program. analogue output; def. setting: Motor current. Ref. point: term. 22 +/- 10V/5mA

26 BU comm. VeCon controlled BU-... braking units command. Ref. point: term. 27 +28V/15mA

27 0V24 Reference point for BU-... command, terminal 26 -


D RESERVED -
28

29 RESERVED

E 36 Digital input 1 +30V

37 Digital input 2 3.2mA at 15V


Programmable digital input; default setting: none
38 Digital input 3 5mA at 24V
F
39 Digital input 4 6.4mA at 30V

41 Digital output 1
Programmable digital output; default setting: none +30V/40mA
G 42 Digital output 2

46 Supply DO Supply input for digital outputs on terminals 41/42. Ref. point: term. 16 +30V/80mA

78
H Motor PTC Motor PTC sensing for overtemperature (cut-off R1k if used) 1.5mA
79

I
Strip X2 Function Max. curr.

X 80
OK relay contact Potential-relay contact OK RELAY (closed = OK)
250VCA
1A, AC11
82

83
Potential-relay contact configurable (relay 2) 250VCA
Relay 2 contact
85 Default: open 0 drive stopped 1A, AC11

H.48
J.48
AV300i
Dimensional drawings and weights
Flux vector drives

Flux vector drives


A
Mounting with external heatsink Wall mounting

Cat. no. Dimensions (mm) Weight


F
(kg)
a b c d D1 D2 E1 E2 E3 E4 E5 Ød
6KAVI43F75 105.5 306.5 199.5 62 69 296.5 69 299.5 99.5 284 9 M5 3.5
6KAVI43001
6KAVI43002
105.5
105.5
306.5
306.5
199.5
199.5
62
62
69
69
296.5
296.5
69
69
299.5
299.5
99.5 284
99.5 284
9
9
M5
M5
3.6
3.7
G
6KAVI43003 105.5 306.5 199.5 62 69 296.5 69 299.5 99.5 284 9 M5 3.7
6KAVI43005 151.5 306.5 199.5 62 115 296.5 115 299.5 145.5 284 9 M5 4.95
6KAVI43007 151.5 306.5 199.5 62 115 296.5 115 299.5 145.5 284 9 M5 4.95
6KAVI43010
6KAVI43015
151.5
208
306,5
323
199.5
240
62
84
115
168
296.5
310.5
115
164
299.5
315
145.5 284
199 299.5
9
9
M5
M5
4.95
8.6
H
6KAVI43020 208 323 240 84 168 310.5 164 315 199 299.5 9 M5 8.6

H.49
J.49
AV300i

Flux vector drives


Speed drive units

G
Cat. no. Dimensions (mm) Weight
(kg)
a b c D1 D2 D3 D4 Ød
H 6KAVI43025 309 489 268 225 - - 475 M6 18
6KAVI43030 309 489 308 225 - - 475 M6 22
6KAVI43040 309 489 308 225 - - 475 M6 22,2
6KAVI43050 376 564 308 - 150 - 550 M6 34
6KAVI43060 376 564 308 - 150 - 550 M6 34
I 6KAVI43075 509 741 297.5 - - 100 725 M6 59
6KAVI43100 509 909 297.5 - - 100 891 M6 75.4
6KAVI43125 509 909 297.5 - - 100 891 M6 80.2
6KAVI43150 509 909 297.5 - - 100 891 M6 86.5
6KAVI43200 509 1174 442 - - 100 1112 M6 105
X

H.50
J.50
AV300i

Foot print filter

Flux vector drives


LOAD
LINE

Cat. no. Dimensions (mm) Weight B


(kg)
a b c D1 E1 P M
EMI-FFP-480-9 375 104 45 360 59 M5 Ø6 1.1
EMI-FFP-480-24 375 150 45 360 105 M5 Ø6 1.4
EMI-FFP-480-30
EMI-FFP-480-40
390
390
200
200
45
45
375
375
155
155
M5
M5
Ø6
Ø6
1.6
2.3
C

D
External brake unit

Cat. no. Losses Dimensions (mm) Weight


(kg)
X
(W) A B C A1 B1 Ø
6KBU300-20 130 144 320 210 71 307 M6 5.2
6KBU300-50 300 144 320 210 71 307 M6 5.7
6KBU300-85 400 144 320 280 71 307 M6 6.8

H.51
J.51
AV300i

Flux vector drives

(wires length)
Speed drive units

LOAD
LINE

Cat. no. Dimensions (mm) Weight


(kg)
a b c d D1 E1 R P
COMP480-42 330 220 70 300 314 45 400 M6 2.8
COMP480-55 330 185 80 300 314 55 500 M6 3.1
COMP480-75 330 220 80 300 314 55 - M6 4
COMP480-100 379 220 90 350 364 65 - M10 5.5
A COMP480-130
COMP480-180
430
438
240
240
110
110
400
400
414
414
80
50
-
500
M10
M10
7.5
11
COMP520-7 255 126 50 225 240 25 300 M5 1
COMP520-16 305 142 55 275 290 30 300 M5 1.3
COMP520-30 335 150 60 305 320 35 400 M5 1.65
B COMP520-42 329 185 70 300 314 45 500 M6 2.25
COMP520-55 329 185 80 300 314 55 500 M6 2.5
COMP520-75 329 220 80 300 314 55 - M6 3.35
COMP520-100 379 220 90 350 364 65 - M10 4.5
COMP520-130 429 240 110 400 414 80 - M10 5.7
C COMP520-180 438 240 110 400 414 50 500 M10 6.1

D
Stand alone filter
E

F
Cat. no. Weight
(kg)

G RANGER 520-280 28

I
Cat. no. Weight
X (kg)
RANGER 520-450 45

Dimensions in mm.

H.52
J.52
Main switches

Plug-in relays and Auxiliary contactors A

Motor protection devices B

Contactors and Thermal overload relays C

Motorstarters D

Control and signalling units E


Series ML - Main switches & Emergency-stop switches for machinery

I.3 Mounting possibilities


Electronic relays F
I.4 Standard programme

I.6 Accessories
Limit switches G
I.7 Enclosed switches

I.8 Technical data


Speed drive units H
I.9 Dimensions
Main switches I

Numerical index X

I.1
Series ML
Main switches
A manual operated main switch must be provided for every mains circuit. It
must be a switch-disconnector corresponding to utilization
category AC23 (IEC 947-3) fulfils the following requirements:

• Disconnecting the electrical equipment from


the main.
• Visible contact indication or a disconnection function by construction (the
handle is in the “OFF” position when all contacts are open.
• If the main switch does not serve simultaneously as an emergency-stop
switch, its handle should not be red.
Black or grey handles are recommended.
• It should be lockable in the off-position (e.g. by padlock).
Main switches

• All active conductors are to be disconnected from the main.


• The breaking capacity should be sufficient. In order to break the current of
the largest motor in a blocked state together with the sum of the operating
currents of the remaining motors/loads.
• The handle of the main switch must be easily accessible and must lie be-
tween 0.6 and 1.9 m above the incomer level.

A Standards Emergency-stop equipment


Complying with: The main switch may fulfil the function of an emergency-stop switch on
B - IEC 947-3
- DIN VDE 0660
certain machines.
The handles must be red on a yellow background.
- low voltage directive 73/73 EEC The contacts of manual operated emergency-stop switch has to be opened
- low voltage directive EMC 89/336 EEC by force.
C
Approvals
D


E

F ➄ ➀

G ➃

H
➀ Front mounting (flush mounting)
➁ Rear mounting
➂ Main contact and PE-or N-terminals for ➀
I ➃ Main contact and PE-or N-terminals for ➁
➄ Auxiliary switch 1NO/1NG for ➀ and ➁
➅ Terminal cover triple for ➀ and ➁
X ➆ Terminal cover single for ➂ and ➃
Mounting possibilities ! pg. I.3
Accessories ! pg. I.6
Technical data ! pg. I.8
Dimensions ! pg. I.9

I.2

32764_I01_I12_E.indd 2 13-07-2005 10:01:01


Series ML
Mounting possibilities
Ith 25A 40A 63A 80A 125A
Series ML 1 ML 1 ML 2 ML 2 ML 3
Type 640 650 660 670 680
Front mounting (flush mounting) Colour
Central fixing
Ø 22.5/30.5 mm for 3 padlocks red/yellow 789178 789179
Ø 22.5/30.5 mm for 3 padlocks black 789180 789181
Ø 22.5/30.5 mm for 1 or 2 padlocks red/yellow 789174 789175
Ø 22.5/30.5 mm for 1 or 2 padlocks black 789176 789177
4-hole fixing
With standard handle black 789239 789240 789241 789242 789243
For 3 padlocks red/yellow 789186 789187 789188 789189 789190
For 3 padlocks black 789191 789192 789193 789194 789195
For 1 or 2 padlocks red/yellow 789182 789183
For 1 or 2 padlocks black 789184 789185

Main switches
Rear mounting
With cover coupling
For 3 padlocks red/yellow 789200 789201 789202 789203 789204
For 3 padlocks black 789205 789206 789207 789208 789209
For 1 or 2 padlocks red/yellow 789196 789197
For 1 or 2 padlocks black 789198 789199
With door coupling
For 3 padlocks red/yellow 789214 789215 789216 789217 789218
For 3 padlocks black 789219 789220 789221 789122 789223
For 1 or 2 padlocks red/yellow 789210 789211
For 1 or 2 padlocks black 789212 789213
DIN-rail mounting
With standard handle
For 1 or 2 padlocks
black
red/yellow
789234
789224
789235
789225
789236
789226
789237
789227
789238
789228
A
For 1 or 2 padlocks black 789229 789230 789231 789232 789233

B
Front mounting DIN-rail mounting

Attention: the padlocks are not included.


F

I.3

32764_I01_I12_E.indd 3 13-07-2005 10:01:02


Series ML
Standard programme - Front mounting
Central fixing Ø 22.5/30.5 mm Red/yellow Black/gray
Diagram Protection Ithe Type Ref. no. Ref. no. Pack

Locking handle With terminal cover IP65 25A 640 789174 789176 1
by 1 or 2 padlocks 006
1 3 5
L1 L2 L3 With terminal cover IP65 40A 650 789175 789177 1
ON

OFF

U V W
(9229) 2 4 6
OFF
ON

Locking handle 1 3 5
With terminal cover IP65 25A 640 789178 789180 1
by 3 padlocks 006 L1 L2 L3 With terminal cover IP65 40A 650 789179 789181 1
ON
Main switches

OFF

U V W
(9229) 2 4 6
OFF
ON

4-hole fixing
With terminal cover IP55 25A 640 789182 789184 1
1 3 5
Locking handle 006 L1 L2 L3 With terminal cover IP55 40A 650 789183 789185 1
by 1 or 2 padlocks ON

OFF

U V W
(9229) 2 4 6
OFF
ON

A
Locking handle 1 3 5
With terminal cover IP55 25A 640 789186 789191 1
B by 3 padlocks 006
ON
L1 L2 L3 With terminal cover
With terminal cover
IP55
IP55
40A
63A
650
660
789187
789188
789192
789193
1
1
OFF With terminal cover IP55 80A 670 789189 789194 1
U V W
With terminal cover IP55 125A 680 789190 789195 1
(9229) 2 4 6
OFF

C ON

With standard IP55 25A 640 789239 1


D black handle 006
1 3 5
L1 L2 L3 IP55 40A 650 789240 1
ON IP55 63A 660 789241 1
OFF IP55 80A 670 789242 1
IP55 125A 680 789243 1
U V W

E (9229)
OFF
ON
2 4 6

Accessories see I.6


F

I.4
Series ML
Standard programme - Rear mounting
DIN-rail mounting Red/yellow Black/gray
Protection Ithe Type Ref. no. Ref. no. Pack

Locking handle With terminal cover IP30 25A 640 789224 789229 1
by 1 or 2 padlocks 006
1 3 5
L1 L2 L3
With terminal cover IP30 40A 650 789225 789230 1
ON With terminal cover IP30 63A 660 789226 789231 1
With terminal cover IP30 80A 670 789227 789232 1
OFF
With terminal cover IP30 125A 680 789228 789233 1
U V W
(9229) 2 4 6
OFF
ON

With standard IP30 25A 640 789234 1


black handle 006
1 3 5
L1 L2 L3 IP30 40A 650 789235 1
ON IP30 63A 660 789236 1

Main switches
OFF
IP30 80A 670 789237 1
IP30 125A 680 789238 1
U V W
(9229) 2 4 6
OFF
ON

With door coupling


With terminal cover IP55 25A 640 789210 789212 1
Locking handle With terminal cover IP55 40A 650 789211 789213 1
by 1 or 2 padlocks
1 3 5
006 L1 L2 L3

ON

OFF

(9229)
OFF
U
2
V
4
W
6
A
ON

B
Locking handle 1 3 5
With terminal cover IP55 25A 640 789214 789219 1
by 3 padlocks 006 L1 L2 L3 With terminal cover IP55 40A 650 789215 789220 1
ON With terminal cover IP55 63A 660 789216 789221 1
OFF With terminal cover IP55 80A 670 789217 789222 1 C
With terminal cover IP55 125A 680 789218 789223 1
U V W
(9229) 2 4 6
OFF
ON

D
With cover coupling

Locking handle 006


1 3 5
L1 L2 L3
With terminal cover
With terminal cover
IP65
IP65
25A
40A
640
650
789196
789197
789198
789199
1
1
E
by 1 or 2 padlocks ON

OFF

F
U V W
(9229) 2 4 6
OFF
ON

G
Locking handle 1 3 5
With terminal cover IP65 25A 640 789200 789205 1
by 3 padlocks 006
ON
L1 L2 L3 With terminal cover
With terminal cover
IP65
IP65
40A
63A
650
660
789201
789202
789206
789207
1
1 H
OFF
With terminal cover IP65 80A 670 789203 789208 1
With terminal cover IP65 125A 680 789204 789209 1
U V W
(9229) 2 4 6
OFF
ON
I

Accessories see I.6


X

I.5
Series ML
Accessories - Fitable contactblocs (1)
Neutral switched Fixed neutral module
Front Rear Front Rear
789244 789245 1 789262 789263 1
ı ı
Series ML1 - Type 640/650 Series ML1 - Type 640/650

789246 789247 1 789264 789265 1


ı ı
Series ML2 - Type 660/670 Series ML2 - Type 660/670

789248 789249 1 789266 ı 789267 3


ı
Series ML3 - Type 680 Series ML3 - Type 680

Switching contact Auxiliary contact NO+NC Ith = 16A


Front Rear Front Rear
Main switches

789250 789251 1 789268 789269 1


ı ı
Series ML1 - Type 640/650 Series ML1 - Type 640/650

789252 789253 1 789268 789269 1


ı ı
Series ML2 - Type 660/670 Series ML2 - Type 660/670

789254 789255 1 789268 ı 789269 1


ı
Series ML3 - Type 680 Series ML3 - Type 680

PE-terminal (Fixed)
Front Rear

A 789256 ı 789257
Series ML1 - Type 640/650
1

789258 789259 1
ı
B Series ML2 - Type 660/670

789260 ı 789261 1
Series ML3 - Type 680

C
Accessories - Terminal cover
D Single terminal cover
(HS1)
Triple terminal cover
(HS3)

789270 1 789272 1
ı ı
E Series ML1 - Type 640/650 Series ML1 - Type 640/650

789271 1 789273 1
ı ı
Series ML2 - Type 660/670 Series ML2 - Type 660/670
F 1
ı 789271 1 ı 789274
Series ML3 - Type 680 Series ML3 - Type 680

Same cover for front- or base mounting


G
Extension shafts for door coupling
H Shaft length ML1
Depth range between door and base (mm)
ML2, ML3 Cat. no.
AL-65 170-215 mm 185-320 mm 789275
AL-165 265-335 mm 280-350 mm 789276
AL-265 (2) 365-435 mm 380-450 mm 789277
I AL-365 (2) 465-535 mm 480-550 mm 789278

Shaft support for 265 and 365 mm 789279

X An extension shaft is necessary when


Example
the depth is higher than the length of
the standard shaft.
ML1: 105-135 mm
ML2 and ML3: 120-150 mm

(1) ML1: max. 2 units


ML2 and ML3: max 3 units
(2) Shaft support included.

I.6

32764_I01_I12_E.indd 6 13-07-2005 10:01:14


Series ML
Enclosed switches

The maintenance switch is an enclosed main switch with locking handle by 3 padlocks.
With red handle and yellow front plate, if it should be used as an emergency-stop switch,
otherwise black/grey.
There are six sizes of standard enclosures for the series ML. Each is equipped with a cover
coupling and a double PE-terminal. Switches type 640 (3 and 4-pole) are provided with an
additional N-terminal.
All enclosures have a degree of protection IP65 and are of solid impact and flame resistant
polyester.

Enclosed switches
Red/yellow Black/grey

Main switches
A /6.
1
1
3
3
5
5
3 padlocks 3 padlocks
Diagram Type Ithe Type of Ref. no. Ref. no. Pack
ON

enclosure
OFF

640 25A E2 789280 789285 1


2 4 6
ML 2 4 6
OFF

Three poles ON
650 32A E3 789281 789286 1
660 50A E4 789282 789287 1
1 3 5
A /6. 1 3 5

670 63A E5 789283 789288 1


ON

680 E7 789284 789289 1


1 3 5 7 9

100A
OFF
A /102. 1 3 5 13 21

ON
2 4 6
ML 2 4 6

OFF OFF

ON

2 4 6 14 22
ML -HI 2 4 6 8 10
OFF

ON

1 3 5 7 9
A /102. 1 3 5 13 21

ON

Four poles 640 25A E2 789290 789295 1


A
OFF
1 3 5 7
A /22. 1 3 5 N

ML ON -HI
2
2
4
4
6
6
14
8
22
10 650 32A E3 789291 789296 1
660 50A E4 789292 789297 1
OFF

OFF

ON

ML -NV
2
2
4
4
6
6
N
8
670 63A E5 789293 789298 1
A
OFF
/6.
1
1
3
3
5
5 680 100A E7 789294 789299 1
B
ON
ON
1 3 5 7
A
OFF
/22. 1 3 5 N

ON

2 4 6
OFFML 2 4 6
1 3 5 7 9 11
A /217.
OFF
1 3 5 N 13 21
ON
2 4 6 N
ML ON -NV 2 4 6 8
OFF

C
OFF

ON

Three poles + (1 NO + 1 NC) ML


A
-NV-HI
/102.
OFF
2

12
4

34
6

56
N

78
14

910
22
12 640 25A E2 789300 789305 1
789301 789306
1 3 5 13 21

ON
ON
650 32A E3 1
A
OFF
/217.
1
1
3
3
5
5
7
N
9
13
11
21
660 50A E4 789302 789307 1
ML
ON
-HI
2
2
4
4
6
6
14
8
22
10
670 63A E5 789303 789308 1
680 100A E7 789304 789309 1
D
OFF OFF

ON
2 4 6 N 14 22
ML -NV-HI 2 4 6 8 10 12
OFF

ON

1 3 5 7
A /22. 1 3 5 N

E
ON

OFF

Four poles + (1 NO + 1 NC) 640 25A E2 789310 789315 1


1 3 5 7 9 11
AML /217.
-NV
12 34 56 NN 13 21
2 4 6 8

650 32A E3 789311 789316 1


ON
OFF

660 50A E4 789312 789317 1


OFF ON

670 63A E5 789313 789318 1


2 4 6 N 14 22

F
ML -NV-HI 2 4 6 8 10 12
OFF

ON 1 3 5 7 9 11
680 100A E7 789314 789319 1
A /217. 1 3 5 N 13 21

ON

OFF

2 4 6 N 14 22
ML -NV-HI 2 4 6 8 10 12

G
OFF

ON

Six poles 640 25A E2 789320 789325 1


650 32A E3 789321 789326 1
660 50A E4 789322 789327 1
670
680
63A
100A
E5
E7
789323
789324
789328
789329
1
1
H

I
Six poles + (1 NO + 1 NC) 640 25A E2 789330 789335 1
650 32A E3 789331 789336 1
660
670
50A
63A
E4
E5
789332
789333
789337
789338
1
1 X
680 100A E7 789334 789339 1

I.7

32764_I01_I12_E.indd 7 13-07-2005 10:01:17


Series ML
Technical data
Main switches - According to IEC 947-3, EN 60947-3, DIN VDE 0660 part 107, UL and CSA
Series ML 1 ML 1 ML 2 ML 2 ML 3
Types 640 650 660 670 680
Rated uninterrupted current Iu open = Ith (A) 25 40 63 80 125
Ithe enclosed (A) 25 32 50 63 100
Rated insulation voltage Ui (III/3) (V) 690 690 690 690 690
Rated impulse withstand voltage Uimp (III/3) (kV) 6 6 6 6 6
Rated operational current Ie AC21 A(3) (A) 25 40 63 80 125
Rated operational voltage Ue (V) 690 690 690 690 690
Frequence (Hz) 50/60 50/60 50/60 50/60 50/60
Making/breaking capacity
Utilization category AC3: 3 x 230V (kW) 5.5 7.5 15 18.5 22
Motor switches for 3 x 400V (kW) 7.5 11 22 30 37
Main switches

operational switching 3 x 690V (kW) 7.5 11 22 30 45


Utilization category AC23A(3) 3 x 230V (kW) 7.5 11 18.5 22 25
Motor switches 3 x 400V (kW) 11 15 30(1) 37(2) 45
(Main switches for machinery) 3 x 690V (kW) 11 15 30(1) 37(2) 45
Rated breaking category AC23 A(3) 3 x 230V (A) 260 390 630 750 870
3 x 400V (A) 220 300 570 700 850
3 x 690V (A) 130 170 330 400 490
Short-circuit capacity
Max. fuse rating gG (A) 50 50 80 80 125
Rated conditional short-circuit current (kAeff) 10 10 – – –
Rated short-circuit making capacity Icm (kA) – – 2.1 2.1 3.4
Rated short-time withstand Icw (1s-current) (Aeff) 300 480 765 960 1500
A Disconnect function up to
Terminal screws (Pozidriv)
(V) 690
M4
690
M4
690
M5
690
M5
690
M6
Torque terminal screws (Nm) 2.5 2.5 4 4 6
Cable cross section

B Solid or multi-stranded (Cu)


Flexible with ferrule (DIN 46228)
min. - max. (mm2)
min. - max. (mm2)
1.5-10
1.5-6
1.5-10
1.5-6
2.5-35
1.5-25
2.5-35
1.5-25
6-70
6-50
General purpose 3-phase (A) 25 40 63 80 125
(V) 600 600 600 600 600
Motor 3-phase 240V (HP) 7.5 10 15 20 25
C 480V (HP) 10 20 30 40 50
600V (HP) 10 20 30 40 50
Motor 1-phase (2 pole) 120V (HP) 1 1,5 3 4 6
240V (HP) 2 3 7,5 10 15
D Cable cross section AWG-No 14-7 14-3 14-2 14-2 8-1/0
(1) 22 kW in enclosure
(2) 30 kW in enclosure
(3) ML2/ML3 according to EN 60947-3 category B
E

F Auxiliary contact for ML 1/2/3 - According to IEC 947-5-1


Series ML 1/2/3
Rated uninterrupted current Iu open = Ith (A) 16
Ithe enclosed (A) 16
G Rated insulation voltage Ui (III/3) (V) 690
Rated impulse withstand voltage Uimp (kV) 6
Rated operational current Ie (AC15)
230V (A) 6
H 400V (A) 4
690V (A) 2
Max. fuse rating gG (A) 16
Rated conditional short-circuit current (kAeff) 3
I Cable cross section, solid or multi-stranded min. - max. (mm2) 1-4
Flexible with ferrule (DIN 46228) min. - max. (mm2) 1-2.5
Terminal screws (Pozidriv) M3
Torque terminal screws (Nm) 0.6
X

I.8
Series ML
Dimensional drawings

Front mounting - Central fixing Ø 22.5/30.5 mm


For 1 or 2 padlocks, Ø max. 5 mm For 3 padlocks, Ø max. 9 mm
max. 5 3.2 (4,8) max. 5 3.2 (4,8)

I
I

D
D

(17)
(17)
22,5 (30,5)

12.5
22,5 (30,5)

12.5
E E
G H
G H
Door F Door
F

Series D E F G H I Series D E F G H I

Dimensions
ML1 55 45 75 25 35 48 ML1 55 45 75 25 35 66

Front mounting - 4-hole fixing


For 1 or 2 padlocks, Ø max. 5 mm For 3 padlocks, Ø max. 5 mm
A A
max. 5 max. 5

12
12

I
G
I
G

D
D

E B1 H B1
F H
E F

Door Door B

Series
ML1
A
36
B1
4.5
D
44
E
44
F
50
G
55
H
32
I
66
C
Series A B1 D E F G H I ML2 48 5.5 58 58 72 75 37 86
ML1 36 4.5 44 44 50 55 35 48 ML3 48 5.5 78 78 72 80 37 86

D
Front mounting - 4-hole fixing, with standard black handle
max. 5 A
E
12

F
I
G
D

B1
E F H

Door
G

Series
ML1
A
36
B1
4.5
D
44
E
44
F
50
G
55
H
29
I
48
H
ML2 48 5.5 58 58 72 75 33 64
ML3 69 5.5 78 78 72 80 35 88

I.9
Series ML
Dimensional drawings

Rear mounting - DIN-rail mounting


With standard black handle For 1 or 2 padlocks, Ø max. 5 mm
H
H
C3 B2 F
C3 F
5 B2
5
A2
A3

A4

A2
A3

A4
45

D
45
B3

B3
E G G
Main switches

E
C2 I C2 I
C4 C4
Boden/base Boden/base

Series A2 A3 A4 B2 B3 C2 C3 Series A2 A3 A4 B2 B3 C2 C3
ML1 60 65 70 4.2 3.8 22 30 ML1 60 65 70 4.2 3.8 22 30
ML2 – 80 90 5.5 5.2 – 23.5 ML2 – 80 90 5.5 5.2 – 23.5
ML3 – 80 90 5.5 5.2 – 23.5 ML3 – 80 90 5.5 5.2 – 23.5
Series C4 D E F G H I Series C4 D E F G H I
ML1 25 78 52.5 42 48.5 87.5 67.5 ML1 25 78 52.5 42 48.5 91.5 67.5
ML2 25 100 53.5 49 – 100 79 ML2 25 100 53.5 49 – 104 79
ML3 25 100 70 49 – 100 79 ML3 25 100 70 79 – 104 79

A
Rear mounting - With door coupling
For 1 or 2 padlocks, Ø max. 5 mm
B B3 K
C3 B2 F
5 A
max. 5

C 12
A3
A1

A2
A4

D H B1
G 70
E min.
C2 Door
C4
Boden/base
C1
E
Series A A2 A3 A4 B1 B2 B3 C2 C3 C4 D E F G H I K
ML1 36 60 65 70 4.5 4.2 3.8 22 30 25 78 45 42 55 35 48 105-135

F
For 3 padlocks, Ø max. 5 mm

G B3
C3 B2 F
K

5 A
max. 5

H
12
I
D
A1
A3

A2
A4

H B1
I E
G
min.
70
C2
Door
C4
Boden/base
C1

X
Series A A2 A3 A4 B1 B2 B3 C2 C3 C4 D E F G H I K
ML1 36 60 65 70 4.5 4.2 3.8 22 30 25 78 45 42 55 32 66 105-135
ML2 36 – 80 90 5.5 5.5 5.2 – 23.5 25 100 53.5 49 72 37 86 120-150
ML3 36 – 80 90 5.5 5.5 5.2 – 23.5 25 100 70 49 72 37 86 120-150

I.10
Series ML

Rear mounting - With cover coupling


For 1 or 2 padlocks, Ø max. 9 mm
B3 K
C3 B2 F
5 A
max. 5

14
A2
A3
A1

A4

I
D
B1
H
G
E
C2 Door
C4

Dimensions
Boden/base
C1

Series A A2 A3 A4 B1 B2 B3 C2 C3 C4 D E F G H I K
ML1 36 60 65 70 4.5 4.2 3.8 22 30 25 78 45 42 55 35 48 105-135

For 3 padlocks, Ø max. 9 mm


B3
C3 B2 F
K
A
5 A
max. 5

14
B
I
D
A2
A1
A3

A4

H B1

C2
E
G

Door
C
C4
Boden/base
C1

Series A A2 A3 A4 B1 B2 B3 C2 C3 C4 D E F G H I K
D
ML1 36 60 65 70 4.5 4.2 3.8 22 30 25 78 45 42 55 32 66 88-98
ML2 36 – 80 90 5.5 5.5 5.2 – 23.5 25 100 53.5 49 72 37 86 103-113
ML3 36 – 80 90 5.5 5.5 5.2 – 23.5 25 100 70 49 72 37 86 103-113
E

Enclosed switches
F
J 2 x H E3
A C D E2

G
5

F3
F2
B

J 2x H
I
I
Enclosure Cable entry
Type A B C D E2 E3 F2 F3 Type H (1) I (1) H (2) I (2) J (2)
E2
E3
94
130
130
130
81
99
32
32


79
115


115
115
E2
E3
PG 16/11
PG 21/16
PG 11
PG 16






X
E4 110 180 11 32 50 95 120 165 E4 – – PG 21 PG 11 –
E5 180 182 111 37 120 165 120 167 E5 – – PG 29 – PG 11
E6 180 254 111 37 120 165 190 239 E6 – – PG 29 PG 11 –
E7 265 265 140 37 194 – 230 – E7 PG 36/29 PG 29 – – –
(1) Knock-out entry
(2) Cable entry

I.11
Series ML
Dimensional drawings

Accessories
N-module and PE-terminal Auxiliary contacts (NO + NC) Terminal covers
D E D D E D G H

F
Main switches

E D

Series D E Series D E Series D E F G H


ML1 14.5 45 ML1 9.5 45 ML1 14.5 45 53 41 14
ML2 23 53.5 ML2 9.5 53.5 ML2 23 53.5 61 52 22.5
ML3 23 70 ML3 9.5 70 ML3 23 70 65 68 22.5

I.12
Control and Automation

Plug-in relays and Auxiliary contactors A

Motor protection devices B

X.2 Completed catalogue numbers Contactors and Thermal overload relays C

X.2 Chap. A - Series M - Auxiliary minicontactors Motorstarters D


X.3 Chap. A - Series RL - Auxiliary contactors
X.4 Chap. C - Series M - Minicontactors Control and signalling units E
X.6 Chap. C - Series CL - Contactors
X.8 Chap. C - Series CK - Contactors Electronic relays F
X.9 Chap. C - Series CSC - Contactors for capacitors
X.10 Chap. E - Series P9 - Control and signalling units Ø 22 mm
Limit switches G
X.12 Chap. E - Series 077 - Control and signalling units Ø 30 mm
Speed drive units H
X.14 General index by catalogue number
Main switches I
X.24 General index by reference number
Numerical index X

X.1
Series M
This list shows the Cat. no. Ref. no. Cat. no. Ref. no.
50/60Hz pg. A.17 MCRC031ATG 100017 48V
catalogue and MB0A1 102407 24V MCRC031ATH 102327 60V
reference numbers for MB0A2 102408 42V MCRC031ATI 102328 72V
MB0A3 102409 110/115V MCRC031ATJ 100018 110V
the auxiliary MB0A4 102410 120V MCRC031ATK 102329 120V
Completed catalogue numbers

minicontactors with MB0A5 102411 220V MCRC031ATL 102330 125V


MB0A6 102412 230V MCRC031ATN 100019 220V
the most usual voltages. MB0A7 102413 240V MCRC031ATR 102331 240V
For other voltages/ MB0A8 102414 440V MCRC031ATS 102324 250V
MB0A9 133717 48V MCRC040AFD 100056 24V
types, please consult us. MCRA004AT1 102097 24V MCRC040AFG 100057 48V
MCRA004AT2 102098 42V MCRC040AID 102332 24V
MCRA004AT3 102099 110/115V MCRC040ATB 100000 12V
Cat. no. Ref. no. MCRA004AT4 102100 120V MCRC040ATC 102315 32V
50Hz pg. A.17 MCRA004AT5 102101 220V MCRC040ATD 100006 24V
MB0AG 100452 48V MCRA004AT6 102102 230V MCRC040ATE 102316 36V
MB0AK 102400 115/127V MCRA004AT7 102103 240V MCRC040ATF 102317 42V
MB0AN 100454 220/240V MCRA004AT8 102104 440V MCRC040ATG 100007 48V
MB0AS 102403 260V MCRA004AT9 108859 48V MCRC040ATH 102318 60V
MB0AU 213532 380/400V MCRA013AT1 102076 24V MCRC040ATI 102319 72V
MB0AW 102405 415/440V MCRA013AT2 102077 42V MCRC040ATJ 100008 110V
MCRA004AFN 100094 220/240V MCRA013AT3 102078 110/115V MCRC040ATK 102320 120V
MCRA004AIN 100144 220/240V MCRA013AT4 102079 120V MCRC040ATL 102321 125V
MCRA004ATG 100042 48V MCRA013AT5 102080 220V MCRC040ATN 100009 220V
MCRA004ATK 102090 115/127V MCRA013AT6 102081 230V MCRC040ATR 102322 240V
MCRA004ATN 100044 220/240V MCRA013AT7 102082 240V MCRC040ATS 100040 250V
MCRA004ATS 102093 260V MCRA013AT8 102083 440V
MCRA004ATU 100045 380/400V MCRA022AF8 107493 440V
MCRA004ATW 102095 415/440V MCRA022AI5 100129 220V
MCRA013AFN 100084 220/240V MCRA022AT1 102055 24V
MCRA013AIN 100134 220/240V MCRA022AT2 102056 42V
MCRA013ATG 100032 48V MCRA022AT3 102057 110/115V
MCRA013ATK 102069 115/127V MCRA022AT4 102058 120V
MCRA013ATN 100034 220/240V MCRA022AT5 102059 220V
MCRA013ATS 102072 260V MCRA022AT6 102060 230V
MCRA013ATU 100035 380/400V MCRA022AT7 102061 240V
MCRA013ATW 102074 415/440V MCRA022AT8 102062 440V

A MCRA022AFG
MCRA022AFN
100072
100074
48V
220/240V
MCRA022AT9
MCRA031AT1
108236
102034
48V
24V
MCRA022AIN 100124 220/240V MCRA031AT2 102035 42V
MCRA022AIU 100125 380/400V MCRA031AT3 102036 110/115V
MCRA022ATG 100022 48V MCRA031AT4 102037 120V
MCRA022ATK 102048 115/127V MCRA031AT5 102038 220V
B MCRA022ATN
MCRA022ATS
100024
102051
220/240V
260V
MCRA031AT6
MCRA031AT7
102039
102040
230V
240V
MCRA022ATU 100025 380/400V MCRA031AT8 102041 440V
MCRA022ATW 102053 415/440V MCRA031AT9 108238 48V
MCRA031AFG 100062 48V MCRA040AT1 102013 24V
MCRA031AFN 100064 220/240V MCRA040AT2 102014 42V
C MCRA031AFU
MCRA031AIG
100065
100112
380/400V
48V
MCRA040AT3
MCRA040AT4
102015
102016
110/115V
120V
MCRA031AIN 100114 220/240V MCRA040AT5 102017 220V
MCRA031AIU 100115 380/400V MCRA040AT6 102018 230V
MCRA031ATG 100012 48V MCRA040AT7 102019 240V
D MCRA031ATK
MCRA031ATN
102027
100014
115/127V
220/240V
MCRA040AT8
MCRA040AT9
102020
108237
440V
48V
MCRA031ATS 102030 260V
MCRA031ATU 100015 380/400V Direct current pg. A.17
MCRA031ATW 102032 415/440V MB0CA 102415 6V
MCRA040AFN 100054 220/240V MB0CB 100460 12V
E MCRA040AFU
MCRA040AIN
100055
100104
380/400V
220/240V
MB0CC
MB0CD
102416
100466
32V
24V
MCRA040ATG 100002 48V MB0CE 102417 36V
MCRA040ATK 102006 115/127V MB0CF 102418 42V
MCRA040ATN 100004 220/240V MB0CG 100467 48V

F MCRA040ATS
MCRA040ATU
102009
100005
260V
380/400V
MB0CI
MB0CJ
102420
100468
72V
110V
MCRA040ATW 102011 415/440V MB0CK 102421 120V
MB0CL 102422 125V
60Hz pg. A.17 MB0CN 100469 220V
MB0AE 102397 32V MB0CR 102423 240V
G MB0AF
MB0AM
102398
102401
48V
208/220V
MB0CS
MB0CH
100449
102419
250V
60V
MB0AU 213532 440V MCRC022AFG 100077 48V
MB0AY 102406 600V MCRC022AFL 102366 125V
MCRA004ATE 102087 32V MCRC022AFN 100079 220V
MCRA004ATM 102091 208/220V MCRC022AID 100126 24V
H MCRA004ATU
MCRA004ATY
100045
102096
440V
600V
MCRC022AIJ
MCRC022ATB
100128
100020
110V
12V
MCRA013ATE 102066 32V MCRC022ATC 102333 32V
MCRA013ATM 102070 208/220V MCRC022ATD 100026 24V
MCRA013ATU 100035 440V MCRC022ATE 102334 36V
I MCRA013ATY
MCRA022AIU
102075
100125
600V
440V
MCRC022ATF
MCRC022ATG
102335
100027
42V
48V
MCRA022ATE 102045 32V MCRC022ATH 102336 60V
MCRA022ATH 102047 110V MCRC022ATI 102337 72V
MCRA022ATM 102049 208/220V MCRC022ATJ 100028 110V
MCRA022ATU 100025 440V MCRC022ATK 102338 120V
X MCRA022ATY
MCRA031AFU
102054
100065
600V
440V
MCRC022ATL
MCRC022ATN
102339
100029
125V
220V
MCRA031AIU 100115 440V MCRC022ATR 102340 240V
MCRA031ATE 102024 32V MCRC022ATS 108953 250V
MCRA031ATM 102028 208/220V MCRC031AFD 100066 24V
MCRA031ATU 100015 440V MCRC031AID 100116 24V
MCRA031ATY 102033 600V MCRC031ATA 102323 6V
MCRA040ATE 102003 32V MCRC031ATB 100010 12V
MCRA040ATM 102007 208/220V MCRC031ATD 100016 24V
MCRA040ATU 100005 440V MCRC031ATE 102325 36V
MCRA040ATY 102012 600V MCRC031ATF 102326 42V

X.2
Series RL
This list shows the Cat. no. Ref. no.
RL4RA040T3 109018 110/115V
catalogue and RL4RA040T4 109019 120V
reference numbers for RL4RA040T5 109020 220V
RL4RA040T6 109021 230V
the auxiliary RL4RA040T7 109022 240V

Completed catalogue numbers


minicontactors with RL4RA040T8 109023 440V

the most usual voltages. Direct current pg. A.23


For other voltages/ LB1DB 112310 12V
LB1DD 112316 24V
types, please consult us. LB1DE 112650 36V
LB1DF 112651 42V
LB1DG 112317 48V
Cat. no. Ref. no. LB1DH 112652 60V
50Hz pg. A.23 LB1DI 112653 72V
LB1AE 110401 32V LB1DJ 112318 110V
LB1AK 110405 127V LB1DK 112654 120/125V
LB1AN 104634 220/230V LB1DN 112319 220V
LB1AU 104635 380/400V LB1DP 112655 230V
LB1AW 110412 415V LB1DR 112656 240V
LB1AZ 110415 660/690V LB1DT 112657 250V
RL4RA004TE 109073 32V LB1DWB 113523 12V (WR)
RL4RA004TK 109077 127V LB1DWD 113524 24V (WR)
RL4RA004TN 104034 220/230V LB1DWE 113525 33V (WR)
RL4RA004TU 104035 380/400V LB1DWG 113526 48V (WR)
RL4RA004TW 109084 415V LB1DWI 113527 72V (WR)
RL4RA004TZ 109087 660/690V LB1DWJ 113528 110V (WR)
RL4RA022TE 109049 32V LB1DWN 113529 220V (WR)
RL4RA022TK 109053 127V LB1DX 112658 440V
RL4RA022TN 104024 220/230V RL4RD004TB 113030 12V
RL4RA022TU 104025 380/400V RL4RD004TD 113036 24V
RL4RA022TW 109060 415V RL4RD004TE 113077 36V
RL4RA022TZ 109063 660/690V RL4RD004TG 113037 48V
RL4RA031TE 109025 32V RL4RD004TJ 113038 110V
RL4RA031TK 109029 127V RL4RD004TK 113081 120/125V
RL4RA031TN 104014 220/230V RL4RD004TN 113039 220V
RL4RA031TU 104015 380/400V RL4RD004TT 113084 250V
RL4RA031TW
RL4RA031TZ
109036
109039
415V
660/690V
RL4RD022GD
RL4RD022GJ
113046
113048
24V
110V A
RL4RA040TE 109001 32V RL4RD022TB 113020 12V
RL4RA040TK 109005 127V RL4RD022TD 113026 24V
RL4RA040TN 104004 220/230V RL4RD022TE 113068 36V
RL4RA040TU 104005 380/400V RL4RD022TG 113027 48V
RL4RA040TW
RL4RA040TZ
109012
109015
415V
660/690V
RL4RD022TJ
RL4RD022TK
113028
113072
110V
120/125V
B
RL4RD022TN 113029 220V
60Hz pg. A.23 RL4RD022TP 113073 230V
LB1AL 110406 208V RL4RD022TT 113075 250V
LB1AT 110410 380V RL4RD031TB 113010 12V
LB1AY
RL4RA004TL
110414
109078
600V
208V
RL4RD031TD
RL4RD031TE
113016
113059
24V
36V
C
RL4RA004TT 109082 380V RL4RD031TG 113017 48V
RL4RA004TY 109086 600V RL4RD031TH 113061 60V
RL4RA022TL 109054 208V RL4RD031TJ 113018 110V
RL4RA022TT
RL4RA022TY
109058
109062
380V
600V
RL4RD031TK
RL4RD031TN
113063
113019
120/125V
220V
D
RL4RA031TL 109030 208V RL4RD031TT 113066 250V
RL4RA031TT 109034 380V RL4RD031TX 113067 440V
RL4RA031TY 109038 600V RL4RD040TB 113000 12V
RL4RA040TL 109006 208V RL4RD040TD 113006 24V
RL4RA040TT
RL4RA040TY
109010
109014
380V
600V
RL4RD040TE
RL4RD040TG
113050
113007
36V
48V
E
RL4RD040TJ 113008 110V
50/60Hz pg. A.23 RL4RD040TK 113054 120/125V
LB1A1 110416 24V RL4RD040TN 113009 220V
LB1A2
LB1A3
110417
110418
42V
110/115V
RL4RD040TT 113057 250V
F
LB1A4 110419 120V Mechanical
LB1A5 110420 220V latch blocks pg. A.24
LB1A6 110421 230V RMLFD 112992
LB1A7 110422 240V RMLFG 112993
LB1A8
LB1A9
110423
113979
440V
48V
RMLFJ
RMLFN
112994
112995
G
RL4RA004T1 109088 24V RMLFU 112996
RL4RA004T2 109089 42V RMLFY 112997
RL4RA004T3 109090 110/115V
RL4RA004T4 109091 120V
RL4RA004T5
RL4RA004T6
109092
109093
220V
230V
H
RL4RA004T7 109094 240V
RL4RA004T8 109095 440V
RL4RA022T1 109064 24V
RL4RA022T2
RL4RA022T3
109065
109066
42V
110/115V
I
RL4RA022T4 109067 120V
RL4RA022T5 109068 220V
RL4RA022T6 109069 230V
RL4RA022T7 109070 240V
RL4RA022T8
RL4RA031T1
109071
109040
440V
24V
X
RL4RA031T2 109041 42V
RL4RA031T3 109042 110/115V
RL4RA031T4 109043 120V
RL4RA031T5 109044 220V
RL4RA031T6 109045 230V
RL4RA031T7 109046 240V
RL4RA031T8 109047 440V
RL4RA040T1 109016 24V
RL4RA040T2 109017 42V

X.3
Series M
This list shows the Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no.
MC1A310ATG 100212 48V MC1A301AFY 102679 600V MC0A400AT5 102801 220V MC1AA00AT7 103034 240V
catalogue and MC1A310ATK 102610 115/127V MC1A301AIM 102716 208/220V MC0A400AT6 102802 230V MC1AA00AT8 103035 440V
reference numbers for MC1A310ATN 100214 220/240V MC1A301AIU 100265 440V MC0A400AT7 102803 240V MC1AB00AF1 103070 24V
MC1A310ATS 102613 260V MC1A301ARU 103404 440V MC0A400AT8 102804 440V MC1AB00AF2 103071 42V
the minicontactors MC1A310ATU 100215 380/400V MC1A301ATE 102628 32V MC0A400AT9 100290 48V MC1AB00AF3 103072 110/115V
Completed catalogue numbers

with the most usual MC1A310ATW 102615 415/440V MC1A301ATM 102632 208/220V MC0AA00AT1 102839 24V MC1AB00AF4 103073 120V
MC1A400AFG 100392 48V MC1A301ATU 100225 440V MC0AA00AT2 102840 42V MC1AB00AF5 103074 220V
voltages. For other MC1A400AFK 103042 115/127V MC1A301ATY 102637 600V MC0AA00AT3 102841 110/115V MC1AB00AF6 103075 230V
voltages/types, please MC1A400AFN 100394 220/240V MC1A310AFE 102649 32V MC0AA00AT4 102842 120V MC1AB00AF7 103076 240V
MC1A400AFS 103045 260V MC1A310AFM 102653 208/220V MC0AA00AT5 102843 220V MC1AB00AF8 103077 440V
consult us. MC1A400AFU 100395 380/400V MC1A310AFU 100235 440V MC0AA00AT6 102844 230V MC1AB00AI9 100427 48V
MC1A400AFW 103047 415/440V MC1A310AFY 102658 600V MC0AA00AT7 102845 240V MC1AB00AT1 103007 24V
MC1A400AIG 100422 48V MC1A310AIU 100255 440V MC0AA00AT8 102846 440V MC1AB00AT2 103008 42V
Cat. no. Ref. no. MC1A400AIN 100424 220/240V MC1A310ARU 103391 440V MC0AB00AT1 102818 24V MC1AB00AT3 103009 110/115V
50Hz pg. C.3-C.5 MC1A400AIU 100425 380/400V MC1A310ATE 102607 32V MC0AB00AT2 102819 42V MC1AB00AT4 103010 120V
MB0AG 100452 48V MC1A400AIW 103110 415/440V MC1A310ATM 102611 208/220V MC0AB00AT3 102820 110/115V MC1AB00AT5 103011 220V
MB0AK 102400 115/127V MC1A400ATG 100362 48V MC1A310ATU 100215 440V MC0AB00AT4 102821 120V MC1AB00AT6 103012 230V
MB0AN 100454 220/240V MC1A400ATK 102979 115/127V MC1A310ATY 102616 600V MC0AB00AT5 102822 220V MC1AB00AT7 103013 240V
MB0AS 102403 260V MC1A400ATN 100364 220/240V MC1A400AFE 103039 32V MC0AB00AT6 102823 230V MC1AB00AT8 103014 440V
MB0AU 213532 380/400V MC1A400ATS 102982 260V MC1A400AFM 103043 208/220V MC0AB00AT7 102824 240V MC1AB00AT9 100400 48V
MB0AW 102405 415/440V MC1A400ATU 100365 380/400V MC1A400AFU 100395 440V MC0AB00AT8 102825 440V MC2A301AI1 103273 24V
MC0A301AFN 100184 220/240V MC1A400ATW 102984 415/440V MC1A400AFY 103048 600V MC1A301AF1 102680 24V MC2A301AI9 103272 48V
MC0A301AIG 100202 48V MC1AA00AFG 100412 48V MC1A400AIY 113267 600V MC1A301AF2 102681 42V MC2A301AR1 103425 24V
MC0A301AIN 100204 220/240V MC1AA00AFK 103084 115/127V MC1A400ATE 102976 32V MC1A301AF3 102682 110/115V MC2A301AR9 103426 48V
MC0A301AIU 100205 380/400V MC1AA00AFN 100414 220/240V MC1A400ATM 102980 208/220V MC1A301AF4 102683 120V MC2A301AT1 103569 24V
MC0A301ARN 103377 220/240V MC1AA00AFS 103087 260V MC1A400ATU 100365 440V MC1A301AF5 102684 220V MC2A301AT3 103358 110/115V
MC0A301ARU 103378 380/400V MC1AA00AFU 100415 380/400V MC1A400ATY 102985 600V MC1A301AF6 102685 230V MC2A301AT5 103570 220V
MC0A301ATG 100162 48V MC1AA00AFW 103089 415/440V MC1AA00AFE 103081 32V MC1A301AF7 102686 240V MC2A301AT6 103571 230V
MC0A301ATK 102451 115/127V MC1AA00AIN 100444 220/240V MC1AA00AFM 103085 208/220V MC1A301AF8 102687 440V MC2A310AI1 103271 24V
MC0A301ATN 100164 220/240V MC1AA00ATG 100382 48V MC1AA00AFU 100415 440V MC1A301AI1 102722 24V MC2A310AI9 103270 48V
MC0A301ATS 102454 260V MC1AA00ATK 103021 115/127V MC1AA00AFY 103090 600V MC1A301AI3 102724 110/115V MC2A310AR1 103412 24V
MC0A301ATU 100165 380/400V MC1AA00ATN 100384 220/240V MC1AA00ATE 103018 32V MC1A301AI5 102726 220V MC2A310AR9 103413 48V
MC0A301ATW 102456 415/440V MC1AA00ATS 103024 260V MC1AA00ATM 103022 208/220V MC1A301AI6 107167 230V MC2A310AT1 103577 24V
MC0A310AFG 100172 48V MC1AA00ATU 100385 380/400V MC1AA00ATU 100385 440V MC1A301AR1 103399 24V MC2A310AT5 103578 220V
MC0A310AFN 100174 220/240V MC1AA00ATW 103026 415/440V MC1AA00ATY 103027 600V MC1A301AR9 103400 48V MC2A310AT6 103579 230V
MC0A310AIG 100192 48V MC1AB00AFG 100402 48V MC1AB00AFE 103060 32V MC1A301AT1 102638 24V MC2A400AT6 103595 230V
MC0A310AIN 100194 220/240V MC1AB00AFK 103063 115/127V MC1AB00AFM 103064 208/220V MC1A301AT2 102639 42V

A MC0A310AIU
MC0A310ARN
100195 380/400V
103364 220/240V
MC1AB00AFN
MC1AB00AFS
100404
103066
220/240V
260V
MC1AB00AFU
MC1AB00AFY
100405
103069
440V
600V
MC1A301AT3
MC1A301AT4
102640
102641
110/115V
120V
Direct current
MB0CA
pg. C.3-C.5
102415 6V
MC0A310ARU 103365 380/400V MC1AB00AFU 100405 380/400V MC1AB00ATE 102997 32V MC1A301AT5 102642 220V MB0CB 100460 12V
MC0A310ATG 100152 48V MC1AB00AFW 103068 415/440V MC1AB00ATM 103001 208/220V MC1A301AT6 102643 230V MB0CC 102416 32V
MC0A310ATK 102430 115/127V MC1AB00AIN 100434 220/240V MC1AB00ATU 100375 440V MC1A301AT7 102644 240V MB0CD 100466 24V
MC0A310ATN 100154 220/240V MC1AB00ATG 100372 48V MC1AB00ATY 103006 600V MC1A301AT8 102645 440V MB0CE 102417 36V
B MC0A310ATS
MC0A310ATU
102433 260V
100155 380/400V
MC1AB00ATK
MC1AB00ATN
103000
100374
115/127V
220/240V
MC2A301ARU
MC2A301ATU
103430
103567
440V
440V
MC1A301AT9
MC1A310AF1
100320
102659
48V
24V
MB0CF
MB0CG
102418 42V
100467 48V
MC0A310ATW 102435 415/440V MC1AB00ATS 103003 260V MC2A310ARU 103417 440V MC1A310AF2 102660 42V MB0CH 102419 60V
MC0A400AFN 100304 220/240V MC1AB00ATU 100375 380/400V MC2A310ATU 103575 440V MC1A310AF3 102661 110/115V MB0CI 102420 72V
MC0A400AIN 100334 220/240V MC1AB00ATW 103005 415/440V MC2A400ATU 103292 440V MC1A310AF4 102662 120V MB0CJ 100468 110V
MC0A400AIU 100335 380/400V MC2A301AIN 101019 220/240V MC1A310AF5 102663 220V MB0CK 102421 120V
C MC0A400ATG
MC0A400ATK
100272 48V
102790 115/127V
MC2A301AIU
MC2A301ARN
103289
103429
380/400V
220/240V
50/60Hz
MB0A1
pg. C.3-C.5
102407 24V
MC1A310AF6
MC1A310AF7
102664
102665
230V
240V
MB0CL
MB0CN
102422 125V
100469 220V
MC0A400ATN 100274 220/240V MC2A301ARU 103430 380/400V MB0A2 102408 42V MC1A310AF8 102666 440V MB0CR 102423 240V
MC0A400ATS 102793 260V MC2A301ATG 103564 48V MB0A3 102409 110/115V MC1A310AI1 102701 24V MB0CS 100449 250V
MC0A400ATU 100275 380/400V MC2A301ATN 103566 220/240V MB0A4 102410 120V MC1A310AI3 102703 110/115V MC0C301AFD 100186 24V
D MC0A400ATW
MC0AA00AIN
102795 415/440V
100354 220/240V
MC2A301ATU
MC2A310AIN
103567
101018
380/400V
220/240V
MB0A5
MB0A6
102411 220V
102412 230V
MC1A310AI5
MC1A310AI9
102705
102706
220V
48V
MC0C301AID
MC0C301ARB
100206 24V
103379 12V
MC0AA00ATG 100292 48V MC2A310AIU 103290 380/400V MB0A7 102413 240V MC1A310AR1 103386 24V MC0C301ARD 103380 24V
MC0AA00ATK 102832 115/127V MC2A310ARN 103416 220/240V MB0A8 102414 440V MC1A310AR9 103387 48V MC0C301ARG 103381 48V
MC0AA00ATN 100294 220/240V MC2A310ARU 103417 380/400V MB0A9 133717 48V MC1A310AT1 102617 24V MC0C301ARH 103382 60V
MC0AA00ATS 102835 260V MC2A310ATG 103572 48V MC0A301AI1 102542 24V MC1A310AT2 102618 42V MC0C301ARJ 103383 110V
E MC0AA00ATU
MC0AA00ATW
100295 380/400V
102837 415/440V
MC2A310ATN
MC2A310ATU
103574
103575
220/240V
380/400V
MC0A301AI3
MC0A301AI5
102544 110/115V
102546 220V
MC1A310AT3
MC1A310AT4
102619
102620
110/115V
120V
MC0C301ARK
MC0C301ARN
103384 120V
103385 220V
MC0AB00AFN 100314 220/240V MC0A301AI6 102547 230V MC1A310AT5 102621 220V MC0C301ATB 100160 12V
MC0AB00AIN 100344 220/240V 60Hz pg. C.3-C.5 MC0A301AR1 103373 24V MC1A310AT6 102622 230V MC0C301ATD 100166 24V
MC0AB00ATG 100282 48V MB0AE 102397 32V MC0A301AR9 103374 48V MC1A310AT7 102623 240V MC0C301ATE 102561 36V

F MC0AB00ATK
MC0AB00ATN
102811 115/127V
100284 220/240V
MB0AF
MB0AM
102398 48V
102401 208/220V
MC0A301AT1
MC0A301AT2
102458 24V
102459 42V
MC1A310AT8
MC1A310AT9
102624
100298
440V
48V
MC0C301ATF
MC0C301ATG
102562 42V
100167 48V
MC0AB00ATS 102814 260V MB0AU 213532 440V MC0A301AT3 102471 110/115V MC1A400AF1 103049 24V MC0C301ATH 102563 60V
MC0AB00ATU 100285 380/400V MB0AY 102406 600V MC0A301AT4 102461 120V MC1A400AF2 103050 42V MC0C301ATI 102564 72V
MC0AB00ATW 102816 415/440V MC0A301AIU 100205 440V MC0A301AT5 102462 220V MC1A400AF3 103051 110/115V MC0C301ATJ 100168 110V
MC1A301AFG 100242 48V MC0A301ARU 103378 440V MC0A301AT6 102463 230V MC1A400AF4 103052 120V MC0C301ATK 102565 120V
G MC1A301AFK
MC1A301AFN
102673 115/127V
100244 220/240V
MC0A301ATE
MC0A301ATM
102448 32V
102452 208/220V
MC0A301AT7
MC0A301AT8
102464 240V
102465 440V
MC1A400AF5
MC1A400AF6
103053
103054
220V
230V
MC0C301ATN
MC0C301ATR
100169 220V
102567 240V
MC1A301AFS 102676 260V MC0A301ATU 100165 440V MC0A301AT9 100299 48V MC1A400AF7 103055 240V MC0C310AFB 100170 12V
MC1A301AFU 100245 380/400V MC0A301ATY 102457 600V MC0A310AF1 102479 24V MC1A400AF8 103056 440V MC0C310AFD 100176 24V
MC1A301AFW 102678 415/440V MC0A310AIM 100147 208/220V MC0A310AF5 102483 220V MC1A400AI1 103112 24V MC0C310AFG 100258 48V
MC1A301AIG 100262 48V MC0A310AIU 100195 440V MC0A310AI1 102521 24V MC1A400AT1 102986 24V MC0C310AID 100196 24V
H MC1A301AIN
MC1A301AIU
100264 220/240V
100265 380/400V
MC0A310ARU
MC0A310ATE
103365 440V
102427 32V
MC0A310AI3
MC0A310AI5
102523 110/115V
102525 220V
MC1A400AT2
MC1A400AT3
102987
102988
42V
110/115V
MC0C310AIG
MC0C310AIJ
100259 48V
100198 110V
MC1A301ARN 103403 220/240V MC0A310ATM 102431 208/220V MC0A310AI6 102526 230V MC1A400AT4 102989 120V MC0C310ARB 103366 12V
MC1A301ARU 103404 380/400V MC0A310ATU 100155 440V MC0A310AI8 107492 440V MC1A400AT5 102990 220V MC0C310ARD 103367 24V
MC1A301ATG 100222 48V MC0A310ATY 102436 600V MC0A310AR1 103360 24V MC1A400AT6 102991 230V MC0C310ARG 103368 48V
I MC1A301ATK
MC1A301ATN
102631 115/127V
100224 220/240V
MC0A400AIM
MC0A400AIU
102917 208/220V
100335 440V
MC0A310AR9
MC0A310AT1
103361 48V
102437 24V
MC1A400AT7
MC1A400AT8
102992
102993
240V
440V
MC0C310ARH
MC0C310ARJ
103369 60V
103370 110V
MC1A301ATS 102634 260V MC0A400ATE 102787 32V MC0A310AT2 102438 42V MC1A400AT9 100296 48V MC0C310ARK 103371 120V
MC1A301ATU 100225 380/400V MC0A400ATM 102791 208/220V MC0A310AT3 102439 110/115V MC1AA00AF1 103091 24V MC0C310ARN 103372 220V
MC1A301ATW 102636 415/440V MC0A400ATU 100275 440V MC0A310AT4 102440 120V MC1AA00AF2 103092 42V MC0C310ATB 100150 12V
MC1A310AFG 100232 48V MC0A400ATY 102796 600V MC0A310AT5 102441 220V MC1AA00AF3 103093 110/115V MC0C310ATC 102551 32V
X MC1A310AFK
MC1A310AFN
102652 115/127V
100234 220/240V
MC0AA00ATE
MC0AA00ATM
102829 32V
102833 208/220V
MC0A310AT6
MC0A310AT7
102442 230V
102443 240V
MC1AA00AF4
MC1AA00AF5
103094
103095
120V
220V
MC0C310ATD
MC0C310ATE
100156 24V
102552 36V
MC1A310AFS 102655 260V MC0AA00ATU 100295 440V MC0A310AT8 102444 440V MC1AA00AF6 103096 230V MC0C310ATF 102553 42V
MC1A310AFU 100235 380/400V MC0AA00ATY 102838 600V MC0A310AT9 100297 48V MC1AA00AF7 103097 240V MC0C310ATG 100157 48V
MC1A310AFW 102657 415/440V MC0AB00ATE 102808 32V MC0A400AF1 113318 24V MC1AA00AF8 103098 440V MC0C310ATH 102554 60V
MC1A310AIG 100252 48V MC0AB00ATM 102812 208/220V MC0A400AF5 100260 220V MC1AA00AT1 103028 24V MC0C310ATI 102555 72V
MC1A310AIN 100254 220/240V MC0AB00ATU 100285 440V MC0A400AI1 100408 24V MC1AA00AT2 103029 42V MC0C310ATJ 100158 110V
MC1A310AIU 100255 380/400V MC0AB00ATY 102817 600V MC0A400AT1 102797 24V MC1AA00AT3 103030 110/115V MC0C310ATK 102556 120V
MC1A310AIW 102699 415/440V MC1A301AFE 102670 32V MC0A400AT2 102798 42V MC1AA00AT4 103031 120V MC0C310ATL 102557 125V
MC1A310ARN 103390 220/240V MC1A301AFM 102674 208/220V MC0A400AT3 102799 110/115V MC1AA00AT5 103032 220V MC0C310ATN 100159 220V
MC1A310ARU 103391 380/400V MC1A301AFU 100245 440V MC0A400AT4 102800 120V MC1AA00AT6 103033 230V MC0C310ATR 102558 60V

X.4
Series M
Cat. no. Ref. no. Cat. no. Ref. no.
MC0C400AFD 100306 24V MC1CB00ATI 103230 72V
MC0C400AFG 100267 48V MC1CB00ATJ 100378 110V
MC0C400AID 100336 24V MC1CB00ATK 103231 120V
MC0C400AIH 103202 60V MC1CB00ATN 100379 220V
MC0C400ATB 100270 12V MC1CB00ATR 103233 240V

Completed catalogue numbers


MC0C400ATD 100276 24V MC1I301ARD 103441 24V
MC0C400ATE 103164 36V MC1I301ATD 100573 24V
MC0C400ATF 103165 42V MC1I310ARD 103440 24V
MC0C400ATG 100277 48V MC1I310ATD 100572 24V
MC0C400ATH 103166 60V MC2C301AIB 103287 12V
MC0C400ATI 103167 72V MC2C301AID 103286 24V
MC0C400ATJ 100278 110V MC2C301AIG 103285 48V
MC0C400ATK 103168 120V MC2C301AIH 103284 60V
MC0C400ATL 103169 125V MC2C301AIJ 103283 110V
MC0C400ATN 100279 220V MC2C301AIK 103282 120V
MC0C400ATR 103170 240V MC2C301AIN 103281 220V
MC0CB00ATB 100280 12V MC2C301ARB 103431 12V
MC0CB00ATD 100286 24V MC2C301ARD 103432 24V
MC0CB00ATE 103173 36V MC2C301ARG 103433 48V
MC0CB00ATF 103174 42V MC2C301ARH 103434 60V
MC0CB00ATG 100287 48V MC2C301ARJ 103435 110V
MC0CB00ATH 103175 60V MC2C301ARK 103436 120V
MC0CB00ATI 103176 72V MC2C301ARN 103437 220V
MC0CB00ATJ 100288 110V MC2C301ATB 103589 12V
MC0CB00ATK 103177 120V MC2C301ATD 103580 24V
MC0CB00ATL 103178 125V MC2C301ATG 103581 48V
MC0CB00ATN 100289 220V MC2C301ATJ 103582 110V
MC0CB00ATR 103179 240V MC2C301ATN 103583 220V
MC1C301AFD 100246 24V MC2C310AIB 103280 12V
MC1C301AFJ 100248 110V MC2C310AID 103279 24V
MC1C301AID 100266 24V MC2C310AIG 103278 48V
MC1C301ARB 103405 12V MC2C310AIH 103277 60V
MC1C301ARD 103406 24V MC2C310AIJ 103276 110V
MC1C301ARG 103407 48V MC2C310AIK 103275 120V
MC1C301ARH 103408 60V MC2C310AIN 103274 220V
MC1C301ARJ 103409 110V MC2C310ARB 103418 12V
MC1C301ARK 103410 120V MC2C310ARD 103419 24V
MC1C301ARN
MC1C301ATB
103411
100220
220V
12V
MC2C310ARG
MC2C310ARH
103420
103421
48V
60V A
MC1C301ATC 102740 32V MC2C310ARJ 103422 110V
MC1C301ATD 100226 24V MC2C310ARK 103423 120V
MC1C301ATE 102741 36V MC2C310ARN 103424 220V
MC1C301ATF 102742 42V MC2C310ATB 103588 12V
MC1C301ATG
MC1C301ATH
100227
102743
48V
60V
MC2C310ATD
MC2C310ATG
103584
103585
24V
48V
B
MC1C301ATI 102744 72V MC2C310ATJ 103586 110V
MC1C301ATJ 100228 110V MC2C310ATN 103587 220V
MC1C301ATK 102745 120V
MC1C301ATL 102746 125V
MC1C301ATN
MC1C301ATR
100229
102747
220V
240V
C
MC1C310AFB 100230 12V
MC1C310AFD 100236 24V
MC1C310AID 100256 24V
MC1C310AIG
MC1C310ARB
100257
103392
48V
12V
D
MC1C310ARD 103393 24V
MC1C310ARG 103394 48V
MC1C310ARH 103395 60V
MC1C310ARJ 103396 110V
MC1C310ARK
MC1C310ARN
103397
103398
120V
220V
E
MC1C310ATB 100210 12V
MC1C310ATD 100216 24V
MC1C310ATE 102732 36V
MC1C310ATF
MC1C310ATG
102733
100217
42V
48V F
MC1C310ATH 102734 60V
MC1C310ATI 102735 72V
MC1C310ATJ 100218 110V
MC1C310ATK 102736 120V
MC1C310ATL
MC1C310ATN
102737
100219
125V
220V
G
MC1C310ATR 102738 240V
MC1C400AIB 100420 12V
MC1C400AID 100426 24V
MC1C400ATB 100360 12V
MC1C400ATD
MC1C400ATE
100366
103218
24V
36V
H
MC1C400ATF 103219 42V
MC1C400ATG 100367 48V
MC1C400ATH 103220 60V
MC1C400ATI
MC1C400ATJ
103221
100368
72V
110V
I
MC1C400ATK 103222 120V
MC1C400ATL 103223 125V
MC1C400ATN 100369 220V
MC1C400ATR 103224 240V
MC1CB00AFD
MC1CB00AFG
100406
100407
24V
48V
X
MC1CB00AHD 103232 24V
MC1CB00AID 100436 24V
MC1CB00ATB 100370 12V
MC1CB00ATC 103226 32V
MC1CB00ATD 100376 24V
MC1CB00ATE 103227 36V
MC1CB00ATF 103228 42V
MC1CB00ATG 100377 48V
MC1CB00ATH 103229 60V

X.5
Series CL
This list shows the Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no.
CL25A310TU 112345 380/400V CL02A310T1 109317 24V CL09A300M7 109706 240V CL03D310MD 112076 24V
catalogue and CL45A300MN 110814 220/230V CL02A310T3 109319 110/115V CL09A311M1 109724 24V CL03D310MJ 112078 110V
reference numbers CL45A300MU 110815 380/400V CL02A310T5 109321 220V CL09A311M3 109726 110/115V
CL03D310MN 112079 220V
CL45A311MN 112804 220/230V CL02A310T7 109323 240V CL09A311M5 109728 220V CL03D310MWD 113153 24V (WR)
for the contactors CL45A311MU 112805 380/400V CL02A400T1 110608 24V CL09A311M7 109730 240V CL03D310MWG 113513 48V (WR)
Completed catalogue numbers

with the most usual LB1AN 104634 220/230V CL02A400T3 110610 110/115V CL09A400M1 110648 24V CL03D310MWN 113489 220V (WR)
LB1AU 104635 380/400V CL02A400T5 110612 220V CL09A400M3 110650 110/115V
CL03D400MB 112190 12V
voltages. For other LB3AN 104644 220/230V CL02A400T7 110614 240V CL09A400M5 110652 220V CL03D400MD 112196 24V
voltages/types, please LB3AU 104645 380/400V CL02AB00T1 110664 24V CL09A400M7 110654 240V CL03D400MJ 112198 110V
LB4AN 104654 220/230V CL02AB00T3 110666 110/115V CL10A300M1 109748 24V CL03D400MN 112199 220V
consult us. LB4AU 104655 380/400V CL02AB00T5 110668 220V CL10A300M3 109750 110/115V
CL03DB00MD 112266 24V
CL02AB00T7 110670 240V CL10A300M5 109752 220V CL03DB00MJ 112268 110V
60Hz pg. C.11-C.13 CL03A300M1 109365 24V CL10A300M7 109754 240V CL03DB00MN 112269 220V
Cat. no. Ref. no. CL00A300TT 109143 380V CL03A300M3 109367 110/115V CL10A311M1 109772 24V CL04D301MB 112100 12V
50Hz pg. C.11/12/13 CL00A301TT 109191 380V CL03A300M5 109369 220V CL10A311M3 109774 110/115V
CL04D301MD 112106 24V
CL00A300TN 104044 220/230V CL00A310TT 109167 380V CL03A300M7 109371 240V CL10A311M5 109776 220V CL04D301MJ 112108 110V
CL00A300TU 104045 380/400V CL01A300TT 109214 380V CL03A301M1 109413 24V CL10A311M7 109778 240V CL04D301MN 112109 220V
CL00A301TN 104064 220/230V CL01A301TT 109262 380V CL03A301M3 109415 110/115V CL25A300T1 110728 24V CL04D301MWG 107009 48V (WR)
CL00A301TU 104065 380/400V CL01A310TT 109238 380V CL03A301M5 109417 220V CL25A300T3 110730 110/115V
CL04D301MWN 113257 220V (WR)
CL00A310TN 104054 220/230V CL01A400TT 109889 380V CL03A301M7 109419 240V CL25A300T5 110732 220V CL04D310MB 112090 12V
CL00A310TU 104055 380/400V CL01AB00TT 110064 380V CL03A310M1 109389 24V CL25A300T7 110734 240V CL04D310MD 112096 24V
CL01A300TN 104074 220/230V CL02A300TT 109287 380V CL03A310M3 109391 110/115V CL25A301T5 112723 220V CL04D310MJ 112098 110V
CL01A300TU 104075 380/400V CL02A301TT 109335 380V CL03A310M5 109393 220V CL25A310T1 112695 24V CL04D310MN 112099 220V
CL01A301TN 104094 220/230V CL02A310TT 109311 380V CL03A310M7 109395 240V CL25A310T3 112697 110/115V
CL04D310MWG 113451 48V (WR)
CL01A301TU 104095 380/400V CL02A400TT 109905 380V CL03A400M1 110616 24V CL25A310T5 112699 220V CL04D310MWN 113490 220V (WR)
CL01A310TN 104084 220/230V CL02AB00TT 110080 380V CL03A400M3 110618 110/115V CL25A310T7 112701 240V CL04D400MB 112202 12V
CL01A310TU 104085 380/400V CL03A300MT 109359 380V CL03A400M5 110620 220V CL45A300M1 110752 24V CL04D400MD 112201 24V
CL01A400TN 104314 220/230V CL03A301MT 109407 380V CL03A400M7 110622 240V CL45A300M3 110754 110/115V
CL04D400MJ 112208 110V
CL01A400TU 104315 380/400V CL03A310MT 109383 380V CL03AB00M1 110672 24V CL45A300M5 110756 220V CL04D400MN 112209 220V
CL01AB00TN 104384 220/230V CL03A400MT 109921 380V CL03AB00M3 110674 110/115V CL45A300M7 110758 240V CL04DB00MB 112270 12V
CL01AB00TU 104385 380/400V CL03AB00MT 110096 380V CL03AB00M5 110676 220V CL45A311M1 112821 24V CL04DB00MD 112276 24V
CL02A300TN 104104 220/230V CL04A300MT 109431 380V CL03AB00M7 110678 240V CL45A311M3 112823 110/115V
CL04DB00MJ 112278 110V
CL02A300TU 104105 380/400V CL04A301MT 109479 380V CL04A300M1 109437 24V CL45A311M5 112825 220V CL04DB00MN 112279 220V
CL02A301RN 108894 220/230V CL04A310MT 109455 380V CL04A300M3 109439 110/115V CL45A311M7 112827 240V CL25D300TB 112060 12V
CL02A301TN 104124 220/230V CL04A400MT 109937 380V CL04A300M5 109441 220V LB1A1 110416 24V CL25D300TD 112066 24V
CL02A301TU 104125 380/400V CL04AB00MT 110112 380V CL04A300M7 109443 240V LB1A3 110418 110/115V
CL25D300TJ 112068 110V
CL02A310TN 104114 220/230V CL05A400MT 109953 380V CL04A301M1 109485 24V LB1A5 110420 220V CL25D300TN 112069 220V

A CL02A310TU
CL02A400TN
104115 380/400V
104324 220/230V
CL05AB00MT
CL06A300MT
110127 380V
109550 380V
CL04A301M3
CL04A301M5
109487
109489
110/115V
220V
LB1A7
LB3A1
110422
110449
240V
24V
CL45D300MB
CL45D300MD
112110
112116
12V
24V
CL02A400TU 104325 380/400V CL06A311MT 109574 380V CL04A301M7 109491 240V LB3A3 110451 110/115V
CL45D300MJ 112118 110V
CL02AB00TN 104394 220/230V CL07A300MT 109598 380V CL04A310M1 109461 24V LB3A5 110453 220V CL45D300MN 112119 220V
CL02AB00TU 104395 380/400V CL07A311MT 109622 380V CL04A310M3 109463 110/115V LB3A7 110455 240V CL45D300MWD 113515 24V (WR)
CL03A300MN 104134 220/230V CL07A400MT 109969 380V CL04A310M5 109465 220V LB4A1 110482 24V CL45D300MWG 113452 48V (WR)
B CL03A300MU
CL03A301MN
104135 380/400V
104154 220/230V
CL07AB00MT
CL08A300MT
110143 380V
109646 380V
CL04A310M7
CL04A400M1
109467
110624
240V
24V
LB4A3
LB4A5
110484
110486
110/115V
220V
CL45D300MWN
LB1DB
113491
112310
220V (WR)
12V
CL03A301MU 104155 380/400V CL08A311MT 109670 380V CL04A400M3 110626 110/115V LB4A7 110488 240V LB1DD 112316 24V
CL03A310MN 104144 220/230V CL08AB00MT 110159 380V CL04A400M5 110628 220V LB1DJ 112318 110V
CL03A310MU 104145 380/400V CL09A300MT 109694 380V CL04A400M7 110630 240V Direct current pg. C.11-C.13 LB1DN 112319 220V
CL03A400MN 104334 220/230V CL09A311MT 109718 380V CL04AB00M1 110680 24V CL00D301TD 112016 24V LB1DWD 113524 24V (WR)
C CL03A400MU
CL03AB00MN
104335 380/400V
104404 220/230V
CL09A400MT
CL10A300MT
109985 380V
109742 380V
CL04AB00M3
CL04AB00M5
110682
110684
110/115V
220V
CL00D301TJ
CL00D301TN
112018 110V
112019 220V
LB1DWG
LB1DWN
113526
113529
48V (WR)
220V (WR)
CL03AB00MU 104405 380/400V CL10A311MT 109766 380V CL04AB00M7 110686 240V CL00D310TB 112000 12V LB3DB 112320 12V
CL04A300MN 104164 220/230V CL25A300TT 110722 380V CL05A400M1 110632 24V CL00D310TD 112006 24V LB3DD 112326 24V
CL04A300MU 104165 380/400V CL45A300MT 110746 380V CL05A400M3 110634 110/115V CL00D310TJ 112008 110V LB3DJ 112328 110V
D CL04A301MN
CL04A301MU
104184 220/230V
104185 380/400V
LB1AT
LB3AT
110410 380V
110443 380V
CL05A400M5
CL05A400M7
110636
110638
220V
240V
CL00D310TN
CL00D310TWD
112009 220V LB3DN
113510 24V (WR) LB3DWD
112329
113531
220V
24V (WR)
CL04A310MN 104174 220/230V LB4AT 110476 380V CL05AB00M1 110688 24V CL00D310TWG 113447 48V (WR) LB3DWG 113533 48V (WR)
CL04A310MU 104175 380/400V CL05AB00M3 110690 110/115V CL00D310TWN 113486 220V (WR) LB3DWN 113536 220V (WR)
CL04A400MN 104344 220/230V 50/60Hz pg. C.11-C.13 CL05AB00M5 110692 220V CL01D301TD 112036 24V
CL04A400MU 104345 380/400V CL00A300T1 109149 24V CL05AB00M7 110694 240V CL01D301TJ 112038 110V With electronic
E CL04AB00MN
CL04AB00MU
104414 220/230V
104415 380/400V
CL00A300T3
CL00A300T5
109151 110/115V
109153 220V
CL06A300M1
CL06A300M3
109556
109558
24V
110/115V
CL01D301TN
CL01D310TB
112039 220V
112020 12V
module
CL05E400MD
pg. C.11-C.13
112216 24/28V
CL05A400MN 104354 220/230V CL00A300T7 109155 240V CL06A300M5 109560 220V CL01D310TD 112026 24V CL05E400MF 112550 42/48V
CL05A400MU 104355 380/400V CL00A301T1 109197 24V CL06A300M7 109562 240V CL01D310TJ 112028 110V CL05E400MJ 112218 110/125V
CL05AB00MN 104424 220/230V CL00A301T3 109199 110/115V CL06A311M1 109580 24V CL01D310TN 112029 220V CL05E400MN 112219 220/250V

F CL05AB00MU
CL06A300MN
104425 380/400V
104214 220/230V
CL00A301T5
CL00A301T7
109201 220V
109203 240V
CL06A311M3
CL06A311M5
109582
109584
110/115V
220V
CL01D310TWD
CL01D310TWG
113511 24V (WR) CL05E400MY
113448 48V (WR) CL05EB00MD
113971 440V
112286 24/28V
CL06A300MU 104215 380/400V CL00A310T1 109173 24V CL06A311M7 109586 240V CL01D310TWN 113487 220V (WR) CL05EB00MF 112619 42/48V
CL06A311MN 104224 220/230V CL00A310T3 109175 110/115V CL07A300M1 109604 24V CL01D400TD 112176 24V CL05EB00MJ 112288 110/125V
CL06A311MU 104225 380/400V CL00A310T5 109177 220V CL07A300M3 110243 110/115V CL01D400TJ 112178 110V CL05EB00MN 112289 220/250V
CL07A300MN 104234 220/230V CL00A310T7 109179 240V CL07A300M5 109608 220V CL01D400TN 112179 220V CL05EB00MY 113968 440V
G CL07A300MU
CL07A311MN
104235 380/400V
104244 220/230V
CL01A300T1
CL01A300T3
109220 24V
109222 110/115V
CL07A300M7
CL07A311M1
109610
109628
240V
24V
CL01DB00TB
CL01DB00TD
112240 12V
112246 24V
CL06E300MD
CL06E300MF
112126 24/28V
112839 42/48V
CL07A311MU 104245 380/400V CL01A300T5 109224 220V CL07A311M3 109630 110/115V CL01DB00TN 112249 220V CL06E300MJ 112128 110/125V
CL07A400MN 104364 220/230V CL01A300T7 109226 240V CL07A311M5 109632 220V CL02D301TB 112050 12V CL06E300MN 112129 220/250V
CL07A400MU 104365 380/400V CL01A301T1 109268 24V CL07A311M7 109634 240V CL02D301TD 112056 24V CL06E300MY 113977 440V
CL07AB00MN 104434 220/230V CL01A301T3 109270 110/115V CL07A400M1 110762 24V CL02D301TJ 112058 110V CL07E300MD 112136 24/28V
H CL07AB00MU
CL08A300MN
104435 380/400V
104254 220/230V
CL01A301T5
CL01A301T7
109272 220V
109275 240V
CL07A400M3
CL07A400M5
110642
110644
110/115V
220V
CL02D301TN
CL02D310TB
112059 220V
112040 12V
CL07E300MF
CL07E300MJ
112850 42/48V
112138 110/125V
CL08A300MU 104255 380/400V CL01A310T1 109244 24V CL07A400M7 110646 240V CL02D310TD 112046 24V CL07E300MN 112139 220/250V
CL08A311MN 104264 220/230V CL01A310T3 109246 110/115V CL07AB00M1 110696 24V CL02D310TJ 112048 110V CL07E300MY 113976 440V
CL08A311MU 104265 380/400V CL01A310T5 109248 220V CL07AB00M3 110698 110/115V CL02D310TN 112049 220V CL07E400MD 112226 24/28V
I CL08AB00MN
CL08AB00MU
104444 220/230V
104445 380/400V
CL01A310T7
CL01A400T1
109250 240V
110600 24V
CL07AB00M5
CL07AB00M7
110700
110702
220V
240V
CL02D310TWD
CL02D310TWG
113512 24V (WR) CL07E400MF
113449 48V (WR) CL07E400MJ
112561 42/48V
112228 110/125V
CL09A300MN 104274 220/230V CL01A400T3 207282 110/115V CL08A300M1 109652 24V CL02D310TWN 113488 220V (WR) CL07E400MN 112229 220/250V
CL09A300MU 104275 380/400V CL01A400T5 110604 220V CL08A300M3 109654 110/115V CL02D400TB 112180 12V CL07E400MY 113970 440V
CL09A311MN 104284 220/230V CL01A400T7 110606 240V CL08A300M5 109656 220V CL02D400TD 112186 24V CL07EB00MD 112296 24/28V
CL09A311MU 104285 380/400V CL01AB00T1 110656 24V CL08A300M7 109658 240V CL02D400TJ 112188 110V CL07EB00MF 112630 42/48V
X CL09A400MN
CL09A400MU
104374 220/230V
104375 380/400V
CL01AB00T3
CL01AB00T5
110658 110/115V
110660 220V
CL08A311M1
CL08A311M3
109676
109678
24V
110/115V
CL02D400TN
CL02D400TWG
112189 220V CL07EB00MJ
112045 48V (WR) CL07EB00MN
112298 110/125V
112299 220/250V
CL10A300MN 104294 220/230V CL01AB00T7 110662 240V CL08A311M5 109680 220V CL02DB00TB 112250 12V CL07EB00MY 113967 440V
CL10A300MU 104295 380/400V CL02A300T1 109293 24V CL08A311M7 109682 240V CL02DB00TD 112256 24V CL08E300MD 112146 24/28V
CL10A311MN 104304 220/230V CL02A300T3 109295 110/115V CL08AB00M1 110704 24V CL02DB00TJ 112258 110V CL08E300MF 112861 42/48V
CL10A311MU 104305 380/400V CL02A300T5 109297 220V CL08AB00M3 110706 110/115V CL02DB00TN 112259 220V CL08E300MJ 112148 110/125V
CL25A300TN 110804 220/230V CL02A300T7 109299 240V CL08AB00M5 110708 220V CL03D301MB 112080 12V CL08E300MN 112149 220/250V
CL25A300TU 110805 380/400V CL02A301T1 109341 24V CL08AB00M7 110710 240V CL03D301MD 112086 24V CL08E300MY 113975 440V
CL25A301TN 112354 220/230V CL02A301T3 109343 110/115V CL09A300M1 109700 24V CL03D301MJ 112088 110V CL08EB00MD 112306 24/28V
CL25A301TU 112355 380/400V CL02A301T5 109345 220V CL09A300M3 109702 110/115V CL03D301MN 112089 220V CL08EB00MF 112641 42/48V
CL25A310TN 112344 220/230V CL02A301T7 109347 240V CL09A300M5 109704 220V CL03D310MB 112070 12V CL08EB00MJ 112308 110/125V

X.6
Series CL
Cat. no. Ref. no.
CL08EB00MN 112309 220/250V
CL08EB00MY 113966 440V
CL09E300MD 112156 24/28V
CL09E300MF 112872 42/48V
CL09E300MJ 112158 110/125V

Completed catalogue numbers


CL09E300MN 112159 220/250V
CL09E300MY 113974 440V
CL09E400MD 112236 24/28V
CL09E400MF 112572 42/48V
CL09E400MJ 112238 110/125V
CL09E400MN 112239 220/250V
CL09E400MY 113969 440V
CL10E300MD 112166 24/28V
CL10E300MF 112503 42/48V
CL10E300MJ 112168 110/125V
CL10E300MN 112169 220/250V
CL10E300MY 113973 440V
LB4ED 112336 24/28V
LB4EF 112670 42/48V
LB4EJ 112338 110/125V
LB4EN 112339 220/250V
LB4EY 113972 440V

Mechanical
latch blocks pg. C.15
RMLFD 112992
RMLFG 112993
RMLFJ 112994
RMLFN 112995
RMLFU 112996
RMLFY 112997

X.7
Series CK
This list shows the Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no.
C04255Y 110513 600V CK10CE311D 133783 24/28V KM4EWF 113551 48V (WR)
catalogue and C04787C 110515 24V CK10CE311F 113692 42/48V KM4EWH 113552 72V (WR)
reference numbers C04787F 119517 48V CK10CE311J 133784 110/127V KM4EWJ 113553 110V (WR)
C04787H 110518 110V CK10CE311N 133286 220/250V KM4EWN 113554 220V (WR)
for the contactors C04787I 110519 120V CK10CE311U 133785 380/415V KM4EY 105318 440/500V
Completed catalogue numbers

with the most usual C04787M 110522 220V CK10CE311Y 113694 440/500V KM5ED 104870 24/28V
C04787S 110523 240V CK10CE411D 133786 24/28V KM5EF 104876 42/48V
voltages. For other C04787T 110525 380V CK10CE411J 133787 110/127V KM5EJ 104877 110/127V
voltages/types, please C04787V 110526 440V CK10CE411N 133287 220/250V KM5EN 104878 220/250V
C04787Y 110529 600V CK10CE411U 133788 380/415V KM5EU 104879 380/415V
consult us. C12168C 105302 24V CK11CE311D 133789 24/28V KM5EWH 104871 72V (WR)
C12168F 105304 48V CK11CE311F 113691 42/48V KM5EY 110833 440/500V
C12168H 133886 110V CK11CE311J 133790 110/127V KM6ED 104880 24/28V
Cat. no. Ref. no. C12168I 104891 120V CK11CE311N 133288 220/250V KM6EF 104886 42/48V
50Hz pg. C.19/20 C12168M 105308 220V CK11CE311U 133791 380/415V KM6EJ 104887 110/127V
C04255D 104811 24V C12168S 105309 240V CK11CE311Y 113688 440/500V KM6EN 104888 220/250V
C04255G 104812 48V C12168T 101060 380V CK11CE411D 133792 24/28V KM6EU 104889 380/415V
C04255J 104813 110V C12168V 105312 440V CK11CE411F 113680 42/48V KM6EY 110834 440/500V
C04255K 110504 127V C12168Y 133838 600V CK11CE411J 133793 110/127V KM7ED 113427 24/28V
C04255N 104814 220/230V CK07BA411C 110322 24V CK11CE411N 133289 220/250V KM7EF 113428 42/48V
C04255R 110508 240V CK07BA411F 110760 48V CK11CE411U 133794 380/415V KM7EJ 113429 110/127V
C04255U 104815 380/400V CK07BA411H 110325 110V CK12BE311D 104516 24/28V KM7EN 113430 220/250V
C04255W 110511 415V CK07BA411I 133798 120V CK12BE311F 110304 42/48V KM7EU 113431 380/415V
C04255X 110512 440V CK07BA411M 110330 220V CK12BE311J 104518 110/127V KM7EY 113432 440/500V
C04255Z 110514 660/690V CK07BA411S 110331 240V CK12BE311N 104519 220/250V
C04787D 104821 24V CK07BA411T 110333 380V CK12BE311U 110305 380/415V
C04787G 104822 48V CK07BA411V 110334 440V CK12BE311Y 110823 440/500V
C04787J 104823 110V CK07BA411Y 110337 600V CK12BE411D 104596 24/28V
C04787K 110520 127V CK08BA411M 110348 220V CK12BE411F 110383 42/48V
C04787N 104824 220/230V CK08CA311F 113272 48V CK12BE411J 104598 110/127V
C04787R 110524 240V CK08CA311H 113130 110V CK12BE411N 104599 220/250V
C04787U 104825 380/400V CK08CA311M 111581 220V CK12BE411U 110384 380/415V
C04787W 110527 415V CK08CA311S 113890 240V CK75CE311D 113106 24/28V
C04787X 110528 440V CK08CA311V 113891 440V CK75CE311F 108972 42/48V
C04787Z 110530 660/690V CK08CA311Y 101047 600V CK75CE311J 113108 110/127V
C12168D 104895 24V CK75CA311C 113100 24V CK75CE311N 113109 220/250V
C12168G 104892 48V CK75CA311F 113102 48V CK75CE311U 113125 380/415V

A C12168J
C12168K
104893 110V
105306 127V
CK75CA311H
CK75CA311I
113111
113112
110V
120V
CK75CE311WD
CK75CE311WE
113521
113445
24V (WR)
33V (WR)
C12168N 104894 220/230V CK75CA311M 133219 220V CK75CE311WF 113458 48V (WR)
C12168R 105310 240V CK75CA311S 113894 240V CK75CE311WH 113471 72V (WR)
C12168U 113888 380/400V CK75CA311V 113895 440V CK75CE311WJ 113484 110V (WR)
C12168W 105313 415V CK75CA311Y 113122 600V CK75CE311WN 113497 220V (WR)
B C12168X
C12168Z
105314 440V
105316 660/690V
CK85BA311H
CK85BA311I
110267
110268
110V
120V
CK75CE311Y
CK85BE311D
113126
104476
440/500V
24/28V
CK07BA411D 104531 24V CK85BA311M 110271 220V CK85BE311F 110280 42/48V
CK07BA411G 104532 48V CK85BA311S 110272 240V CK85BE311J 104478 110/127V
CK07BA411J 104533 110V CK85BA311V 110275 440V CK85BE311N 104479 220/250V
CK07BA411K 110327 127V CK85BA311Y 101048 600V CK85BE311U 110281 380/415V
C CK07BA411N
CK07BA411R
104534 220/230V
110332 240V 50/60Hz pg. C.19/20
CK95BE311D
CK95BE311F
104616
104610
24/28V
42/48V
CK07BA411U 104535 380/400V C08998J 104833 110V CK95BE311J 104618 110/127V
CK07BA411W 110335 415V C08998N 104834 220/240V CK95BE311N 104614 220/250V
CK07BA411X 110336 440V C08998U 104835 380/440V CK95BE311U 104611 380/415V
D CK07BA411Z
CK08BA411D
110338 660/690V
104541 24V
C09120J
C09120N
212822 110V
204790 220/240V
CK95BE311WH
CK95BE311Y
104617
113375
72V (WR)
440/500V
CK08BA411G 104542 48V C09120U 204792 380/440V CK95BE411D 104560 24/28V
CK08BA411J 104543 110V CK13BA311J 104523 110V CK95BE411F 110377 42/48V
CK08BA411K 110346 127V CK13BA311N 104524 220/240V CK95BE411J 104572 110/127V
CK08BA411N 104544 220/230V CK13BA311U 104525 380/440V CK95BE411N 104569 220/250V
E CK08BA411R
CK08BA411U
110350 240V
104545 380/400V
CK13BA411J
CK13BA411N
104603 110V
104604 220/240V
CK95BE411U
KB4ED
110378
104956
380/415V
24/28V
CK08BA411W 110353 415V CK13BA411U 104605 380/440V KB4EF 133913 42/48V
CK08CA311D 113131 24V KB4EJ 104957 110/127V
CK08CA311G 113132 48V With electronic KB4EN 104958 220/250V

F CK08CA311J
CK08CA311K
113133 110V
113140 127V
module
CK07BE411D
pg. C.19/20
104536 24/28V
KB4EU
KB4EWD
104959
113543
380/415V
24V (WR)
CK08CA311N 133187 220/230V CK07BE411F 110339 42/48V KB4EWE 113544 33V (WR)
CK08CA311R 113889 240V CK07BE411J 104538 110/127V KB4EWF 113545 48V (WR)
CK08CA311U 113135 380/400V CK07BE411N 104539 220/250V KB4EWH 113546 72V (WR)
CK08CA311W 113147 415V CK07BE411U 110340 380/415V KB4EWJ 113547 110V (WR)
G CK75CA311D
CK75CA311G
113101 24V
113892 48V
CK08BE411D
CK08BE411J
104546 24/28V
104548 110/127V
KB4EWN
KB4EY
113548
105317
220V (WR)
440/500V
CK75CA311J 113103 110V CK08BE411N 104549 220/250V KB5ED 104850 24/28V
CK75CA311K 113113 127V CK08BE411U 110358 380/415V KB5EF 104856 42/48V
CK75CA311N 133188 220/230V CK08CE311D 113136 24/28V KB5EJ 104857 110/127V
CK75CA311R 113893 240V CK08CE311F 113151 42/48V KB5EN 104858 220/250V
H CK75CA311U
CK75CA311W
113105 380/400V
113120 415V
CK08CE311J
CK08CE311N
113138 110/127V
113139 220/250V
KB5EU
KB5EWH
104859
104855
380/415V
72V (WR)
CK85BA311D 104471 24V CK08CE311U 113152 380/415V KB5EY 110831 440/500V
CK85BA311G 110266 48V CK08CE311WD 113522 24V (WR) KB6ED 104860 24/28V
CK85BA311J 104473 110V CK08CE311WE 113446 33V (WR) KB6EF 104866 42/48V
I CK85BA311K
CK85BA311N
110269 127V
104474 220/230V
CK08CE311WF
CK08CE311WH
113459 48V (WR)
113472 72V (WR)
KB6EJ
KB6EN
104867
104868
110/127V
220/250V
CK85BA311R 110273 240V CK08CE311WJ 113485 110V (WR) KB6EU 104869 380/415V
CK85BA311U 104475 380/400V CK08CE311WN 113498 220V (WR) KB6EY 110832 440/500V
CK85BA311W 110276 415V CK08CE311Y 113374 440/500V KB7ED 113675 24/28V
CK85BA311X 110277 440V CK09BE311D 104486 24/28V KB7EF 133911 42/48V
X CK85BA311Z 110278 660/690V CK09BE311F
CK09BE311J
104480 42/48V
104488 110/127V
KB7EJ
KB7EN
113673
113672
110/127V
220/250V
60Hz pg. C.19/20 CK09BE311N 104489 220/250V KB7EU 113671 380/415V
C04255C 110499 24V CK09BE311U 110299 380/415V KB7EY 113670 440/500V
C04255F 110501 48V CK09BE311Y 104493 440/500V KM4ED 104960 24/28V
C04255H 110502 110V CK09BE411D 104556 24/28V KM4EF 104966 42/48V
C04255I 110503 120V CK09BE411F 110375 42/48V KM4EJ 104967 110/127V
C04255M 110506 220V CK09BE411J 104558 110/127V KM4EN 104968 220/250V
C04255S 110507 240V CK09BE411N 104559 220/250V KM4EU 104969 380/415V
C04255T 110509 380V CK09BE411U 110376 380/415V KM4EWD 113549 24V (WR)
C04255V 110510 440V CK09BE411Y 113224 440/500V KM4EWE 113550 33V (WR)

X.8
Series CSC
This list shows the Cat. no. Ref. no.
LB3AL 110439 208V
catalogue and LB3AT 110443 380V
reference numbers for LB3AY 110447 600V
LB4AH 110469 110V
the contactors for LB4AL 110472 208V

Completed catalogue numbers


capacitors with the LB4AT 110476 380V
LB4AY 110480 600V
most usual voltages.
For other voltages/ 50/60Hz pg. C.75
CSC12A3111 113245 24V
types, please consult us. CSC12A3115 108954 220V
CSC12A3116 113240 230V
CSC16A3025 113669 220V
Cat. no. Ref. no. CSC16A3115 108955 220V
50Hz pg. C.75 CSC16A3116 113277 230V
CSC12A302N 113589 220/230V CSC20A3011 113246 24V
CSC12A302U 113425 380/400V CSC20A3016 113247 230V
CSC12A311U 107003 380/400V CSC20A3106 113278 230V
CSC12A311W 113231 415V CSC20A3215 108956 220V
CSC12A320N 113591 220/230V CSC25A3016 108862 230V
CSC16A302N 113586 220/230V CSC25A3106 113280 230V
CSC16A302U 113402 380/400V CSC25A3215 108957 220V
CSC16A311U 113395 380/400V CSC30A3101 108922 24V
CSC16A311W 108977 415V CSC30A3106 113241 230V
CSC16A320N 113588 220/230V CSC30A3215 108958 220V
CSC16A320U 113242 380/400V CSC45A3115 108959 220V
CSC20A301N 113584 220/230V CSC55A3115 108960 220V
CSC20A310N 113585 220/230V CSC70A3115 108961 220V
CSC20A310U 108861 380/400V LB1A1 110416 24V
CSC20A310W 113233 415V LB1A2 110417 42V
CSC20A312N 113582 220/230V LB1A3 110418 110/115V
CSC20A312U 113401 380/400V LB1A4 110419 120V
CSC20A312W 108281 415V LB1A5 110420 220V
CSC20A321N 113583 220/230V LB1A6 110421 230V
CSC20A321U 113332 380/400V LB1A7 110422 240V
CSC25A301N 113580 220/230V LB1A8 110423 440V
CSC25A310N 113581 220/230V LB1A9 113979 48V
CSC25A310U
CSC25A310W
113383
108795
380/400V
415V
LB3A1
LB3A2
110449
110450
24V
42V A
CSC25A312N 113578 220/230V LB3A3 110451 110/115V
CSC25A312U 113403 380/400V LB3A4 110452 120V
CSC25A312W 113387 415V LB3A5 110453 220V
CSC25A321N 113579 220/230V LB3A6 110454 230V
CSC25A321W
CSC30A301N
113235
113576
415V
220/230V
LB3A7
LB3A8
110455
110456
240V
440V
B
CSC30A310N 113577 220/230V LB3A9 133192 48V
CSC30A310U 113243 380/400V LB4A1 110482 24V
CSC30A312N 113574 220/230V LB4A2 110483 42V
CSC30A312U 113690 380/400V LB4A3 110484 110/115V
CSC30A321W
CSC45A301N
113236
113572
415V
220/230V
LB4A4
LB4A5
110485
110486
120V
220V
C
CSC45A310N 113573 220/230V LB4A6 110487 230V
CSC45A310W 108208 415V LB4A7 110488 240V
CSC45A311N 113570 220/230V LB4A8 110489 440V
CSC45A311W
CSC45A312N
113237
113569
415V
220/230V
LB4A9 113322 48V
D
CSC45A312U 113392 380/400V
CSC45A320N 113571 220/230V
CSC55A301N 113567 220/230V
CSC55A310N 113568 220/230V
CSC55A310U
CSC55A310W
113382
108209
380/400V
415V
E
CSC55A311N 113565 220/230V
CSC55A312N 113564 220/230V
CSC55A320N 113566 220/230V
CSC70A301N
CSC70A310N
113562
113563
220/230V
220/230V F
CSC70A310W 108210 415V
CSC70A311N 113560 220/230V
CSC70A311W 113239 415V
CSC70A312N 113559 220/230V
CSC70A312U
CSC70A320N
113276
113561
380/400V
220/230V
G
LB1AE 110401 32V
LB1AK 110405 127V
LB1AN 104634 220/230V
LB1AU 104635 380/400V
LB1AW
LB1AZ
110412
110415
415V
660/690V
H
LB3AE 110434 32V
LB3AN 104644 220/230V
LB3AU 104645 380/400V
LB3AW
LB3AZ
110445
110448
415V
660/690V
I
LB4AE 110467 32V
LB4AK 110471 127V
LB4AN 104654 220/230V
LB4AU 104655 380/400V
LB4AW
LB4AZ
110478
110481
415V
660/690V
X
60Hz pg. C.75
CSC12A311T 107515 380V
CSC20A310T 107516 380V
CSC30A310T 107517 380V
CSC45A310T 107518 380V
LB1AL 110406 208V
LB1AT 110410 380V
LB1AY 110414 600V

X.9
Series P9
This list shows the Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no.
Pilot lights P9XSMZ5R 185281 red P9XSAZ1I 185668 clear P9XSMU0L 185196 bleu
catalogue and unibloc pg. E.20 P9XSMZ5G 185283 yellow P9XSAZ5V 185672 green P9XSMU0N 185190 black
reference numbers for P9XUVRD0 185832 green P9XSMZ5L 185286 bleu P9XSAZ5R 185671 red P9XSME3V 185292 green
P9XURRD0 185831 red P9XSMZ5N 185280 black P9XSAZ5G 185673 yellow P9XSME3R 185291 red
the control and P9XUGRD0 185833 yellow P9XSVD0V 183801 green P9XSAZ5L 185676 bleu P9XSME3G 185293 yellow
Completed catalogue numbers

signalling units Ø 22 P9XULRD0 185836 bleu P9XSVD0R 183800 red P9XSAZ5B 185677 white P9XSME3L 185296 bleu
P9XUBRD0 185837 white P9XSVD0G 183802 yellow P9XSAZ5A 185675 amber P9XSME3N 185290 black
mm with the most P9XUARD0 185835 amber P9XSVD0L 183803 bleu P9XSAZ5I 185678 clear P9XSML3V 185302 green
usual colours. For other P9XUIRD0 185838 clear P9XSVD0N 185370 black P9XSML3R 185301 red
P9XUVDD0 185822 green P9XSVD5V 183813 green Push-buttons - P9XSML3G 185303 yellow
types, please consult us. P9XURDD0 185821 red P9XSVD5R 183812 red 3 positions pg. E.13 P9XSML3L 185306 bleu
P9XUGDD0 185823 yellow P9XSVD5G 183814 yellow P9XET4VN2 185082 green P9XSML3N 185300 black
P9XULDD0 185826 bleu P9XSVD5L 183815 bleu P9XET4RN2 185081 red P9XSMU3V 185312 green
Cat. no. Ref. no. P9XUBDD0 185827 white P9XSVD5N 185373 black P9XET4GN2 185083 yellow P9XSMU3R 185311 red
Push-buttons P9XUADD0 185825 amber P9XSVZ0V 183837 green P9XET4LN2 185086 bleu P9XSMU3G 185313 yellow
standard pg. E.13 P9XUIDD0 185828 clear P9XSVZ0R 183836 red P9XET4VN3 185092 green P9XSMU3L 185316 bleu
P9XPNVG 185002 green P9XUVRRN 185852 green P9XSVZ0G 183838 yellow P9XET4RN3 185091 red P9XSMU3N 185310 black
P9XPNRG 185001 red P9XURRRN 185851 red P9XSVZ0L 183839 bleu P9XET4GN3 185093 yellow P9XSME1V 185212 green
P9XPNGG 185003 yellow P9XUGRRN 185853 yellow P9XSVZ0N 185379 black P9XET4LN3 185096 bleu P9XSME1R 185211 red
P9XPNLG 185006 bleu P9XULRRN 185856 bleu P9XSVZ3V 183885 green P9XET4NN3 185090 black P9XSME1G 185213 yellow
P9XPNBG 185007 white P9XUBRRN 185857 white P9XSVZ3R 183884 red P9XSME1L 185216 bleu
P9XPNNG 185000 black P9XUARRN 185855 amber P9XSVZ3G 183886 yellow Emergency illuminated P9XSME1N 185210 black
P9XPNHG 185008 grey P9XUIRRN 185858 clear P9XSVZ3L 183887 bleu push-buttons, P9XSML1V 185222 green
P9XPNMG 185004 brown P9XUVDRN 185842 green P9XSVZ3N 185391 black 3 positions pg. E18 P9XSML1R 185221 red
P9XPN0G 185009 w/o button P9XURDRN 185841 red P9XSVZ1V 183853 green P9XET4VL2 185572 green P9XSML1G 185223 yellow
P9XPNVS 185012 green P9XUGDRN 185843 yellow P9XSVZ1R 183852 red P9XET4RL2 185571 red P9XSML1L 185226 bleu
P9XPNRS 185011 red P9XULDRN 185846 bleu P9XSVZ1G 183854 yellow P9XET4GL2 185573 yellow P9XSML1N 185220 black
P9XPNGS 185013 yellow P9XUBDRN 185847 white P9XSVZ1L 183855 bleu P9XET4LL2 185576 bleu P9XSMU1V 185232 green
P9XPNLS 185016 bleu P9XUADRN 185845 amber P9XSVZ1N 185383 black P9XET4BL2 185577 white P9XSMU1R 185231 red
P9XPNBS 185017 white P9XUIDRN 185848 clear P9XSVZ5V 183869 green P9XET4AL2 185575 amber P9XSMU1G 185233 yellow
P9XPNNS 185010 black P9XSVZ5R 183868 red P9XET4IL2 185578 clear P9XSMU1L 185236 bleu
P9XPNHS 185018 grey Emergency P9XSVZ5G 183870 yellow P9XET4VL3 185582 green P9XSMU1N 185230 black
P9XPNMS 185014 brown push-buttons pg. E.13 P9XSVZ5L 183871 bleu P9XET4RL3 185581 red P9XSME5V 185252 green
P9XPN0S 185019 w/o button P9XEM3VN 185032 green P9XSVZ5N 185387 black P9XET4GL3 185583 yellow P9XSME5R 185251 red
P9MPNVE 184022 green P9XEM3RN 185031 red P9XET4LL3 185586 bleu P9XSME5G 185253 yellow
P9MPNRE 184021 red P9XEM3GN 185033 yellow Illuminated selector P9XET4BL3 185587 white P9XSME5L 185256 bleu
P9MPNGE 184023 yellow P9XEM3LN 185036 bleu switches pg. E.18 P9XET4AL3 185585 amber P9XSME5N 185250 black

A P9MPNLE
P9MPNBE
184026 bleu
184027 white
P9XEM3NN
P9XEM4VN
185030 black
185042 green
P9XSLD0V
P9XSLD0R
185592
185591
green
red
P9XET4IL3 185588 clear P9XSML5V
P9XSML5R
185262
185261
green
red
P9MPNNE 184020 black P9XEM4RN 185041 red P9XSLD0G 185593 yellow Not illuminated P9XSML5G 185263 yellow
P9MPNHE 184028 grey P9XEM4GN 185043 yellow P9XSLD0L 185596 bleu selector switches, P9XSML5L 185266 bleu
P9MPNME 184024 brown P9XEM4LN 185046 bleu P9XSLD0B 185597 white 2 positions pg. E.14/15 P9XSML5N 185260 black
P9MPN0E 184029 w/o button P9XEM4NN 185040 black P9XSLD0A 185595 amber P9XSMI0V 185122 green P9XSMU5V 185272 green
B Illuminated
P9XEM6VN
P9XEM6RN
185052 green
185051 red
P9XSLD0I
P9XSLZ0V
185598
185602
clear
green
P9XSMI0R
P9XSMI0G
185121 red
185123 yellow
P9XSMU5R
P9XSMU5G
185271
185273
red
yellow
push-buttons pg. E.18 P9XEM6GN 185053 yellow P9XSLZ0R 185601 red P9XSMI0L 185126 bleu P9XSMU5L 185276 bleu
P9XPLVGD 185492 green P9XEM6LN 185056 bleu P9XSLZ0G 185603 yellow P9XSMI0N 185120 black P9XSMU5N 185270 black
P9XPLRGD 185491 red P9XEM6NN 185050 black P9XSLZ0L 185606 bleu P9XSMI5V 185152 green P9XSVE0V 183825 green
P9XPLGGD 185493 yellow P9XET4VN1 185062 green P9XSLZ0B 185607 white P9XSMI5R 185151 red P9XSVE0R 183824 red
C P9XPLLGD
P9XPLBGD
185496 bleu
185497 white
P9XET4RN1
P9XET4GN1
185061 red
185063 yellow
P9XSLZ0A
P9XSLZ0I
185605
185608
amber
clear
P9XSMI5G
P9XSMI5L
185153 yellow
185156 bleu
P9XSVE0G
P9XSVE0L
183826
183827
yellow
bleu
P9XPLAGD 185495 amber P9XET4LN1 185066 bleu P9XSLZ3V 185632 green P9XSMI5N 185150 black P9XSVE0N 185376 black
P9XPLIGD 185498 clear P9XET4NN1 185057 black P9XSLZ3R 185631 red P9XSVI0V 183805 green P9XSVL0V 183829 green
P9XPLVSD 185502 green P9XSLZ3G 185633 yellow P9XSVI0R 183804 red P9XSVL0R 183828 red
D P9XPLRSD
P9XPLGSD
185501 red
185503 yellow
Emergency
push-buttons
illuminated
pg. E.18
P9XSLZ3L
P9XSLZ3B
185636
185637
bleu
white
P9XSVI0G
P9XSVI0L
183806 yellow
183807 bleu
P9XSVL0G
P9XSVL0L
183830
183831
yellow
bleu
P9XPLLSD 185506 bleu P9XEM4VL 185552 green P9XSLZ3A 185635 amber P9XSVI0N 185371 black P9XSVL0N 185377 black
P9XPLBSD 185507 white P9XEM4RL 185551 red P9XSLZ3I 185638 clear P9XSVI5V 183817 green P9XSVU0V 183833 green
P9XPLASD 185505 amber P9XEM4GL 185553 yellow P9XSLZ1V 185612 green P9XSVI5R 183816 red P9XSVU0R 183832 red
P9XPLISD 185508 clear P9XEM4LL 185556 bleu P9XSLZ1R 185611 red P9XSVI5G 183818 yellow P9XSVU0G 183834 yellow
E P9XPLVED
P9XPLRED
185512 green
185511 red
P9XEM4BL
P9XEM4AL
185557 white
185555 amber
P9XSLZ1G
P9XSLZ1L
185613
185616
yellow
bleu
P9XSVI5L
P9XSVI5N
183819 bleu
185374 black
P9XSVU0L
P9XSVU0N
183835
185378
bleu
black
P9XPLGED 185513 yellow P9XEM4IL 185558 clear P9XSLZ1B 185617 white P9XSMH0V 185132 green P9XSVE3V 183873 green
P9XPLLED 185516 bleu P9XET4VL1 185562 green P9XSLZ1A 185615 amber P9XSMH0R 185131 red P9XSVE3R 183872 red
P9XPLBED 185517 white P9XET4RL1 185561 red P9XSLZ1I 185618 clear P9XSMH0G 185133 yellow P9XSVE3G 183874 yellow

F P9XPLAED
P9XPLIED
185515 amber
185518 clear
P9XET4GL1
P9XET4LL1
185563 yellow
185566 bleu
P9XSLZ5V
P9XSLZ5R
185622
185621
green
red
P9XSMH0L
P9XSMH0N
185136 bleu
185130 black
P9XSVE3L
P9XSVE3N
183875
185388
bleu
black
P9MPLVED 184512 green P9XET4BL1 185567 white P9XSLZ5G 185623 yellow P9XSMH1V 185162 green P9XSVL3V 183877 green
P9MPLRED 184511 red P9XET4AL1 185565 amber P9XSLZ5L 185626 bleu P9XSMH1R 185161 red P9XSVL3R 183876 red
P9MPLGED 184513 yellow P9XET4IL1 185568 clear P9XSLZ5B 185627 white P9XSMH1G 185163 yellow P9XSVL3G 183878 yellow
P9MPLLED 184516 bleu P9XSLZ5A 185625 amber P9XSMH1L 185166 bleu P9XSVL3L 183879 bleu
G P9MPLBED
P9MPLAED
184517 white
184515 amber
Selector switches
not illuminated pg. E.14/15
P9XSLZ5I
P9XSAD0V
185628
185642
clear
green
P9XSMH1N
P9XSVH0V
185160 black
183809 green
P9XSVL3N
P9XSVU3V
185389
183881
black
green
P9MPLIED 184518 clear P9XSMD0V 185112 green P9XSAD0R 185641 red P9XSVH0R 183808 red P9XSVU3R 183880 red
P9XSMD0R 185111 red P9XSAD0G 185643 yellow P9XSVH0G 183810 yellow P9XSVU3G 183882 yellow
Pilot lights pg. E.20 P9XSMD0G 185113 yellow P9XSAD0L 185646 bleu P9XSVH0L 183811 bleu P9XSVU3L 183883 bleu
P9XLVR 185802 green P9XSMD0L 185116 bleu P9XSAD0B 185647 white P9XSVH0N 185372 black P9XSVU3N 185390 black
H P9XLRR
P9XLGR
185801 red
185803 yellow
P9XSMD0N
P9XSMD5V
185110 black
185142 green
P9XSAD0A
P9XSAD0I
185645
185648
amber
clear
P9XSVH1V
P9XSVH1R
183821 green
183820 red
P9XSVE1V
P9XSVE1R
183841
183840
green
red
P9XLLR 185806 bleu P9XSMD5R 185141 red P9XSAZ0V 185652 green P9XSVH1G 183822 yellow P9XSVE1G 183842 yellow
P9XLBR 185807 white P9XSMD5G 185143 yellow P9XSAZ0R 185651 red P9XSVH1L 183823 bleu P9XSVE1L 183843 bleu
P9XLAR 185805 amber P9XSMD5L 185146 bleu P9XSAZ0G 185653 yellow P9XSVH1N 185375 black P9XSVE1N 185380 black
I P9XLIR
P9XLVD
185808 clear
185792 green
P9XSMD5N
P9XSMZ0V
185140 black
185202 green
P9XSAZ0L
P9XSAZ0B
185656
185657
bleu
white Not iiluminated
P9XSVL1V
P9XSVL1R
183845
183844
green
red
P9XLRD 185791 red P9XSMZ0R 185201 red P9XSAZ0A 185655 amber selector switches, P9XSVL1G 183846 yellow
P9XLGD 185793 yellow P9XSMZ0G 185203 yellow P9XSAZ0I 185658 clear 3 positions pg. E.14/15 P9XSVL1L 183847 bleu
P9XLLD 185796 bleu P9XSMZ0L 185206 bleu P9XSAZ3V 185682 green P9XSME0V 185172 green P9XSVL1N 185381 black
P9XLBD 185797 white P9XSMZ0N 185200 black P9XSAZ3R 185681 red P9XSME0R 185171 red P9XSVU1V 183849 green
X P9XLAD
P9XLID
185795 amber
185798 clear
P9XSMZ3V
P9XSMZ3R
185322 green
185321 red
P9XSAZ3G
P9XSAZ3L
185683
185686
yellow
bleu
P9XSME0G
P9XSME0L
185173 yellow
185176 bleu
P9XSVU1R
P9XSVU1G
183848
183850
red
yellow
P9XLVV 185812 green P9XSMZ3G 185323 yellow P9XSAZ3B 185687 white P9XSME0N 185170 black P9XSVU1L 183851 bleu
P9XLRV 185811 red P9XSMZ3L 185326 bleu P9XSAZ3A 185685 amber P9XSML0V 185182 green P9XSVU1N 185382 black
P9XLGV 185813 yellow P9XSMZ3N 185320 black P9XSAZ3I 185688 clear P9XSML0R 185181 red P9XSVE5V 183857 green
P9XLLV 185830 bleu P9XSMZ1V 185242 green P9XSAZ1V 185662 green P9XSML0G 185183 yellow P9XSVE5R 183856 red
P9XLBV 185817 white P9XSMZ1R 185241 red P9XSAZ1R 185661 red P9XSML0L 185186 bleu P9XSVE5G 183858 yellow
P9XLAV 185815 amber P9XSMZ1G 185243 yellow P9XSAZ1G 185663 yellow P9XSML0N 185180 black P9XSVE5L 183859 bleu
P9XLIV 185818 clear P9XSMZ1L 185246 bleu P9XSAZ1L 185666 bleu P9XSMU0V 185192 green P9XSVE5N 185384 black
P9XSMZ1N 185240 black P9XSAZ1B 185667 white P9XSMU0R 185191 red P9XSVL5V 183862 green
P9XSMZ5V 185282 green P9XSAZ1A 185665 amber P9XSMU0G 185193 yellow P9XSVL5R 183862 red

X.10
Series P9
Cat. no. Ref. no. Cat. no. Ref. no.
P9XSVL5G 183862 yellow P9YPLLGD 185936 bleu
P9XSVL5L 183862 bleu P9YPLBGD 185937 white
P9XSVL5N 183862 black P9YPLAGD 185935 amber
P9XSVU5V 183865 green P9YPLIGD 185938 clear
P9XSVU5R 183864 red P9YPLVSD 185942 green

Completed catalogue numbers


P9XSVU5G 183866 yellow P9YPLRSD 185941 red
P9XSVU5L 183867 bleu P9YPLGSD 185943 yellow
P9XSVU5N 185386 black P9YPLLSD 185946 bleu
P9YPLBSD 185947 white
Selector switches P9YPLASD 185945 amber
with key, P9YPLISD 185948 clear
3 positions pg. E.16/17
P9XSCE0T95 185418 Func. E Pilot lights,
P9XSCL0T95 185425 Func. L base mounting pg.E.25
P9XSCU0T95 185432 Func. U P9YLVD 185952 green
P9XSCE3C95 185464 Func. E P9YLRD 185951 red
P9XSCL3C95 185465 Func. L P9YLGD 185953 yellow
P9XSCU3C95 185466 Func. U P9YLLD 185956 bleu
P9XSCE1N95 185442 Func. E P9YLBD 185957 white
P9XSCL1N95 185445 Func. L P9YLAD 185955 amber
P9XSCU1N95 185448 Func. U P9YLID 185958 clear
P9XSCE5H95 185454 Func. E
P9XSCL5H95 185457 Func. L Power supplies,
P9XSCU5H95 185460 Func. U integrated LED pg. E.27
P9PLNBDA 197036 amber
Not illuminated P9PLNBDB 197037 white
selector switches, P9PLNBDG 197038 yellow
4 positions pg. E.14/15 P9PLNBDL 197039 bleu
P9XSMX0V 185559 green P9PLNBDR 197040 red
P9XSMX0R 185331 red P9PLNBDV 197041 green
P9XSMX0G 185333 yellow
P9XSMX0L 185336 bleu
P9XSMX0N 185330 black
P9XSMX5V 185342 green
P9XSMX5R 185341 red
P9XSMX5G 185343 yellow
P9XSMX5L 185346 bleu
P9XSMX5N
P9XSVX0V
185340 black
183889 green A
P9XSVX0R 183888 red
P9XSVX0G 183890 yellow
P9XSVX0L 183891 bleu
P9XSVX0N 185392 black
P9XSVX5V
P9XSVX5R
183893 green
183892 red
B
P9XSVX5G 183894 yellow
P9XSVX5L 183895 bleu
P9XSVX5N 185393 black

Not illuminated
selector switches,
C
5 positions pg. E.14/15
P9XSMY0V 185352 green
P9XSMY0R 185351 red
P9XSMY0G
P9XSMY0L
185353 yellow
185356 bleu
D
P9XSMY0N 185350 black
P9XSMW0V 185362 green
P9XSMW0R 185361 red
P9XSMW0G 185363 yellow
P9XSMW0L
P9XSMW0N
185366 bleu
185360 black
E
P9TSMY0N 191350 black
P9TSMW0N 191360 black
P9XSVY0V 183897 green
P9XSVY0R
P9XSVY0G
183896 red
183898 yellow F
P9XSVY0L 183899 bleu
P9XSVY0N 185394 black
P9XSVW0V 183901 green
P9XSVW0R 183900 red
P9XSVW0G
P9XSVW0L
183902 yellow
183903 bleu
G
P9XSVW0N 185395 black

Push-buttons standard,
base mounting pg. E.25
P9YPNVG
P9YPNRG
185902
185901
green
red
H
P9YPNGG 185903 yellow
P9YPNLG 185906 bleu
P9YPNBG 185907 white
P9YPNNG
P9YPNHG
185900
185908
black
grey
I
P9YPNMG 185904 brown
P9YPNVS 185912 green
P9YPNRS 185911 red
P9YPNGS 185913 yellow
P9YPNLS
P9YPNBS
185916
185917
bleu
white
X
P9YPNNS 185910 black
P9YPNHS 185918 grey
P9YPNMS 185914 brown

Illuminated push-buttons
base mounting pg. E.25
P9YPLVGD 185932 green
P9YPLRGD 185931 red
P9YPLGGD 185933 yellow

X.11
Series 077
This list shows the Cat. no. Ref. no.
077GELV 180972 green
catalogue and 077GELG 180973 yellow
reference numbers for 077GELA 180975 orange
077GELBL 180976 blue
the control and 077GELB 180977 white
Completed catalogue numbers

signalling units Ø 30 077GELI 180978 clear

mm with the most Illuminated


usual colours. For other selector switches
Lenses pg. E.59
types, please consult us. 077MISR 181151 red
077MISV 181152 green
077MISG 181153 yellow
Cat. no. Ref. no. 077MISA 181155 orange
Mushroom 077MISBL 181156 blue
head caps pg. E.51 077MISB 181157 white
077EN 180070 black
077ER 180071 red Illuminated
077EV 180072 green selector switches -
077EG 180073 yellow 3 positions pg. E.60
077ISB11TJRC 181225 110-120V
Selector switches
with knob - Illuminated
2 positions pg. E.52 selector switches -
077SDN11 180170 black Lenses pg. E.60
077SDR11 180171 red 077MISR 181151 red
077SDV11 180172 green 077MISV 181152 green
077SDG11 180173 yellow 077MISG 181153 yellow
077SDBL11 180176 blue 077MISA 181155 orange
077SHN11 180180 black 077MISBL 181156 blue
077SHR11 180181 red 077MISB 181157 white
077SHV11 180182 green 077MISI 181158 clear

Selector switches Pilot lights -


with knob - Lenses pg. E.61/62
3 positions pg. E.52 077GLR 181401 red
077SBN11 180230 black 077GLV 181402 green

A 077SBR11
077SBV11
180231
180232
red
green
077GLG
077GLA
181403 yellow
181405 orange
077SBG11 180233 yellow 077GLBL 181406 blue
077SBBL11 180236 blue 077GLB 181407 white
077SXN22 180220 black 077GLI 181408 clear
077SXR22 180221 red 077GLRV 181341 red
B Selector switches
077GLVV
077GLGV
181342 green
181343 yellow
with knob - 077GLAV 181345 orange
4 positions pg. E.52 077GLBLV 181346 blue
077SXV22 180222 green 077GLBV 181347 white
077GLIV 181348 clear
C Selector
push-buttons -
099GW1R
099GW1V
181271 red
181272 green
2 positions pg. E.56 099GW1A 181275 orange
077PSN201 180670 black 099GW1BL 181276 blue
077PSR201 180671 red 099GW1B 181277 white
D 077PSN202
077PSR202
180680
180681
black
red
099GW1I
077GDLVR
181278 clear
181281 black
077PSN203 180690 black 077GDLVV 181282 green
077PSR203 180691 red 077GDLVG 181283 yellow
077PSN204 180700 black
077PSR204 180701 red Accessories pg. E.63-E.65
E 077PSN205
077PSR205
180710
180711
black
red
077MN
077MR
181590 black
181591 red
077PSN206 180720 black 077MV 181592 green
077PSN213 180730 black 077MG 181593 yellow
077PSR213 180731 red 077MBL 181596 blue

F 077PSN221
077PSN222
180740
180750
black
black
077CPN
077CPR
181580 black
181581 red
077PSR222 180751 red 077CPV 181582 green
077PSN231 180760 black 077CPG 181583 yellow
077PSR231 180761 red BA9S6LR 187871 red
077PSN235 180770 black BA9S6LV 187872 green
G 077PSR235
077PSN236
180771
180780
red
black
BA9S6LG
BA9S6LB
187873 yellow
187875 white
077PSR236 180781 red BA9S12LR 187881 black
BA9S12LV 187882 green
Selector BA9S12LG 187883 yellow
push-buttons - BA9S24LR 187891 black
H 3 positions
077PSN301 180790
pg. E.56
black
BA9S24LV
BA9S24LG
187892 green
187893 yellow
077PSR301 180791 red BA9S24LB 187895 White
077PSN302 180800 black BA9S48LR 187901 black
077PSR302 180801 red BA9S48LV 187902 green
I 077PSN311
077PSN323
180810
180820
black
black
BA9S48LG
BA9S110LR
187903 yellow
187911 black
077PSR323 180821 red BA9S110LV 187912 green
077PSN325 180830 black BA9S110LG 187913 yellow
077PSR325 180831 red BA9S110LB 187915 white
BA9S230LR 187921 red
X Illuminated
push-buttons -
BA9S230LG
BA9S230LB
187922 yellow
187926 white
Lenses pg. E.58
077GPLR 180961 red
077GPLV 180962 green
077GPLG 180963 yellow
077GPLA 180965 orange
077GPLBL 180966 blue
077GPLB 180967 white
077GPLI 180968 clear
077GELR 180971 red

X.12
Control and Automation
Notes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Completed catalogue numbers


. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

X.13
Control and Automation
Cat. no Ref. no. Page Cat. no Ref. no. Page Cat. no Ref. no. Page Cat. no Ref. no. Page
077... 077GSBCN 180010 E.50 077PTB11 181615 E.67 077SP12SFE 180545 E.68
077-01 180003 E.67 077GSBCS 180040 E.50 077RE01 180099 E.51 077SP16 180531 E.68
077-01D 180006 E.67 077ISB11D0 181170 E.60 077RE10 180089 E.51 077SP16SFE 180546 E.68
077-01R 180008 E.67 077ISB11D0RC 181174 E.60 077RE11 180079 E.51 077SP1M 180522 E.68
077-10 180002 E.67 077ISD01D0 181064 E.59 077RER 180090 E.51 077SP1MSFE 180537 E.68
077-10A 180007 E.67 077ISD10D0 181063 E.59 077SBN11DC 180250 E.52 077SP1SFE 180536 E.68
077-10D 180005 E.67 077ISD11D0 181060 E.59 077SBN11RC 180260 E.52 077SP2 180523 E.68
077-11 180001 E.67 077ISZ11D0 181172 E.60 077SBN11SC 180240 E.52 077SP20 180532 E.68
077-11D 180004 E.67 077ISZ11D0RC 181176 E.60 077SCB1101 180840 E.54 077SP20SFE 180547 E.68
077BA15D130 181634 E.65 077L2 181350 E.62 077SCB1103 180841 E.54 077SP25 180533 E.68
077BA15D140 181635 E.65 077L4 181351 E.62 077SCB1105 180842 E.54 077SP25SFE 180548 E.68
077BA15D220 181636 E.65 077LDMVD 181305 E.61 077SCB1107 180846 E.54 077SP2M 180524 E.68
By catalogue number

077BA15D230 181637 E.65 077LDNV0 181300 E.61 077SCB1109 180844 E.54 077SP2MSFE 180539 E.68
077BA15D24 181630 E.65 077LPS 181604 E.63 077SCB1114 180845 E.54 077SP2SFE 180538 E.68
077BA15D30 181631 E.65 077LREVJ 181303 E.61 077SCB1120 180843 E.54 077SP3 180525 E.68
077BA15D60 181632 E.65 077LREVL 181304 E.61 077SCB11DC07 180852 E.55 077SP30 180534 E.68
077BA15D60 181633 E.65 077LRNVJ 181301 E.61 077SCB11RC03 180853 E.55 077SP30SFE 180549 E.68
077C3095 173095 E.38 077LRNVN 181302 E.61 077SCB11SC03 180848 E.55 077SP36 180535 E.68
077C3095 173095 E.64 077M2S2SX44 180918 E.57 077SCD1101 180630 E.54 077SP36SF 180554 E.68
077C3353 173353 E.38 077M2S2SX44B 181008 E.57 077SCD1105 180631 E.54 077SP36SFC 180552 E.68
077C3353 179353 E.64 077M2S2SY44 180922 E.57 077SCD1109 180632 E.54 077SP36SFC 180552 E.68
077C9901 173901 E.38 077M2S2SY44B 181012 E.57 077SCH1103 180634 E.54 077SP36SFE 180550 E.68
077C9901 179901 E.64 077M2S2TX44 180921 E.57 077SCH11SC03 180636 E.54 077SP3SFE 180540 E.68
077C9902 173902 E.38 077M2S2TX44B 181011 E.57 077SCI1103 180637 E.54 077SP4 180527 E.68
077C9902 179902 E.64 077M2S2TY44 180925 E.57 077SCI1105 180638 E.54 077SP4SFE 180542 E.68
077C9903 173903 E.38 077M2S2TY44B 181015 E.57 077SCI1114 180639 E.54 077SP4V 180526 E.68
077C9903 179903 E.64 077M2T2SX44 180920 E.57 077SCI11DC03 180640 E.54 077SP4VSF 180553 E.68
077C9904 173904 E.38 077M2T2SX44B 181010 E.57 077SCU2201 180882 E.54 077SP4VSFC 180551 E.68
077C9904 179904 E.64 077M2T2SY44 180924 E.57 077SCU2203 180883 E.54 077SP4VSFE 180541 E.68
077C9905 173905 E.38 077M2T2SY44B 181014 E.57 077SCU2205 180884 E.54 077SP6 180528 E.68
077C9905 179905 E.64 077M2T2TX44 180919 E.57 077SCU2207 180885 E.54 077SP6SFE 180543 E.68
077C9910 173910 E.38 077M2T2TX44B 181009 E.57 077SCU2209 180886 E.54 077SP9 180529 E.68
077C9910 179910 E.64 077M2T2TY44 180923 E.57 077SCU2220 180888 E.54 077SP9SFE 180544 E.68
A 077C9916
077C9916
173916
179916
E.38
E.64
077M2T2TY44B
077M4S4SX88
181013
180926
E.57
E.57
077SCU22DC01
077SCU22DC03
180892
180893
E.55
E.55
077SUN22
077SUN22DC
180440
180460
E.52
E.52
077C9919 173919 E.38 077M4S4SX88B 181016 E.57 077SCU22DC07 180894 E.55 077SUN22RC 180470 E.52
077C9919 179919 E.64 077M4S4SY88 180930 E.57 077SCU22RC03 180895 E.55 077SUN22SC 180450 E.52
077CF73033 173033 E.38 077M4S4SY88B 181020 E.57 077SCU22SC03 180890 E.55 077SZN22 180480 E.52
B 077CF73033
077CF73034
173333
173034
E.64
E.38
077M4S4TX88
077M4S4TX88B
180929
181019
E.57
E.57
077SCU22SC05
077SCU22SC14
180889
180891
E.55
E.55
077SZN22DC
077SZN22RC
180500
180510
E.52
E.52
077CF73034 173334 E.64 077M4S4TY88 180933 E.57 077SCX2201 180650 E.55 077SZN22SC 180490 E.52
077CF73037 173037 E.38 077M4S4TY88B 181023 E.57 077SCX2202 180651 E.55 077TGR 181720 E.66
077CF73037 173337 E.64 077M4T4SX88 180928 E.57 077SCX2204 180652 E.55 077TNA 181650 E.66
C 077CF73038
077CF73038
173038
173338
E.38
E.64
077M4T4SX88B
077M4T4SY88
181018
180932
E.57
E.57
077SCX2205
077SCX2228
180653
180666
E.55
E.55
077TNA2
077TNA230
181660
181930
E.66
E.66
077CF73040 173040 E.38 077M4T4SY88B 181022 E.57 077SCZ2201 180896 E.54 077TNA231 181931 E.66
077CF73040 181622 E.64 077M4T4TX88 180927 E.57 077SCZ2207 180899 E.54 077TNA232 181932 E.66
077CPLT 181600 E.63 077M4T4TX88B 181017 E.57 077SCZ2209 180900 E.54 077TNA233 181933 E.66
D 077CPT
077CR455
181588
173455
E.63
E.38
077M4T4TY88
077M4T4TY88B
180931
181021
E.57
E.57
077SCZ2220
077SCZ22DC01
180902
180906
E.54
E.55
077TNA234
077TNA3
181934
181670
E.66
E.66
077CSCN 181606 E.63 077MT1234S22 180915 E.57 077SCZ22DC03 180907 E.55 077TNA301 181951 E.66
077CSLN 181605 E.63 077MT1234S22B 181005 E.57 077SCZ22DC07 180908 E.55 077TNA310 181960 E.66
077CST 181603 E.63 077MT123S422 180916 E.57 077SCZ22RC03 180909 E.55 077TNA311 181961 E.66
E 077DAE
077DAMP
181554
181557
E.63
E.63
077MT123S422B
077MT234S122
181006
180917
E.57
E.57
077SCZ22SC03
077SCZ22SC05
180904
180903
E.55
E.55
077TNA312
077TNA313
181962
181963
E.66
E.66
077DIM 181553 E.63 077MT234S122B 181007 E.57 077SCZ22SC14 180905 E.55 077TNA4 181680 E.66
077DLB15 181290 E.62 077MT24S22 180911 E.57 077SEN11 180270 E.52 077TNA40 181840 E.66
077DLE14 181260 E.62 077MT24S22B 181001 E.57 077SEN11DC 180290 E.52 077TNA41 181841 E.66
F 077DPP
077DRR
181550
181555
E.63
E.63
077MT24S22R
077MT24S22RB
180913
181003
E.57
E.57
077SEN11RC
077SEN11SC
180300
180280
E.52
E.52
077TNA42
077TNA43
181842
181843
E.66
E.66
077E01 180069 E.51 077MTS123422 180914 E.57 077SHN11 180180 E.52 077TNA44 181844 E.66
077E10 180059 E.51 077MTS123422B 181004 E.57 077SHN11SC 180190 E.52 077TNA45 181845 E.66
077E11 180049 E.51 077MTS2422 180910 E.57 077SIN11 180200 E.52 077TNA46 181846 E.66
G 077ECR
077GE01
181602
181618
E.51
E.64
077MTS2422B
077MTS2422R
181000
180912
E.57
E.57
077SIN11DC
077SLB11
180210
180607
E.52
E.53
077TNA47
077TNA48
181847
181848
E.66
E.66
077GE02 181619 E.64 077MTS2422RB 181002 E.57 077SLB11DC 180609 E.53 077TNA49 181849 E.66
077GE35 181620 E.63 077OPZ 181570 E.63 077SLB11RC 180610 E.53 077TNA50 181850 E.66
077GEBCF 180138 E.50 077P01 180039 E.50 077SLB11SC 180608 E.53 077TNA52 181851 E.66
H 077GEBCN
077GEBCS
180030
180060
E.50
E.50
077P10
077P11
180029
180019
E.50
E.50
077SLD11
077SLE11
180601
180611
E.53
E.53
077TNA53
077TNA54
181852
181853
E.66
E.66
077GG01 181613 E.64 077P11T180 180121 E.50 077SLE11DC 180613 E.53 077TNA55 181854 E.66
077GG02 181614 E.64 077P11T30 180120 E.50 077SLE11RC 180614 E.53 077TNA56 181855 E.66
077GG03 180980 E.58 077PC11C 180100 E.51 077SLE11SC 180612 E.53 077TNA59 181857 E.66
I 077GG03
077GGBCF
180980
180137
E.64
E.50
077PC11CH
077PC11DH
212677
200254
E.51
E.51
077SLH11
077SLH11SC
180602
180603
E.53
E.53
077TNA60
077TNA61
181858
181856
E.66
E.66
077GGBCN 180020 E.50 077PC11E 180101 E.51 077SLI11 180604 E.53 077TNC 181700 E.66
077GGBCR 181556 E.63 077PC11EH 200255 E.51 077SLI11DC 180605 E.53 077TNCS 181710 E.66
077GGBCS 180050 E.50 077PC11F 180102 E.51 077SLU22 180619 E.53 077TPF 181601 E.63
X 077GGM
077GGM
180981
180981
E.58
E.64
077PC11FH
077PC11G
215248
180104
E.51
E.51
077SLU22DC
077SLU22RC
180621
180622
E.53
E.53
080...
080CPDT 173208 E.21
077GGT 180982 E.58 077PLM02D0 181042 E.58 077SLU22SC 180620 E.53 080CPT 170198 E.36
077GGT 180982 E.64 077PLM10D0 181043 E.58 077SLX22 180606 E.53 080ESL 170212 E.37
077GL2B 181377 E.62 077PLM10RJ 181045 E.58 077SLZ22 180623 E.53 080KCSP 170883 E.32
077GL4B 181387 E.62 077PLM10RN 181047 E.58 077SLZ22DC 180625 E.53 080KCSP 170883 E.68
077GS01 181610 E.64 077PLM11D0 181040 E.58 077SLZ22RC 180626 E.53 080QDF001 187715 E.35
077GS02 181611 E.64 077PLM20D0 181041 E.58 077SLZ22SC 180624 E.53 080QDF002 187716 E.35
077GS03 181612 E.64 077PTB01 181609 E.67 077SP1 180521 E.68 080QDF005 187717 E.35
077GSBCF 180136 E.50 077PTB10 181608 E.67 077SP12 180530 E.68 080QDF006 187705 E.35

X.14
Control and Automation
Cat. no Ref. no. Page Cat. no Ref. no. Page Cat. no Ref. no. Page Cat. no Ref. no. Page
080QDF012 187706 E.35 080XTGR01 179525 E.39 115PC002L 132507 G.18 390/3926PFZCS450 213574 C.85
080QDF013 187707 E.35 080XTGR02 179526 E.39 115PC015 132501 G.18 390/3926PMZI 202304 C.85
080QDF014 187708 E.35 080XTGR03 179510 E.39 115PC015L 132508 G.18 390/3926PZ 202654 C.85
080QDF017 187709 E.35 080XTGR04 179527 E.39 115PC018 132502 G.18 390/3927F4/2 214137 C.86
080QDF018 187710 E.35 080XTGR05 179528 E.39 115PC018 132509 G.18 390/3927F5/2 214138 C.86
080QDF026 187711 E.35 080XTGR06 179529 E.39 115PC119 132503 G.18 390/3927M4/2 214139 C.86
080QDF027 185788 E.35 080XTGR07 179530 E.39 115PC119 132510 G.18 390/3927M5/2 214140 C.86
080QDF028 187702 E.35 080XTGR08 179531 E.39 115PC2002 132504 G.18 390/3927PFRN 202306 C.86
080QDF029 187701 E.35 090... 115PC2002L 132511 G.18 390/3927PFZCS320 202307 C.86
080QDF030 185789 E.35 090MI1 130310 E.83 115PC2015 132505 G.18 390/3927PFZCS630 202308 C.86
080QDF031 187713 E.35 090MI1 130310 G.19 115PC2015L 132512 G.18 390/3927PMRN 202309 C.86
080QDF032 187714 E.35 090MI2 130311 E.83 115PC2018 132513 G.18 390/3927PZ 202311 C.86

By catalogue number
080QDF035 187703 E.35 090MI2 130311 G.19 115PC2018 132515 G.18 390/392PMZI 202310 C.86
080QDF038 187704 E.35 099... 115PC2119 132506 G.18 39012Y110D 202323 C.84
080QDF201 187719 E.35 099CH1 181621 E.64 115PC2119 132514 G.18 39012Y125D 202324 C.84
080QDF202 187720 E.35 099E14160 181733 E.65 115PD15210 132521 G.18 39012Y197D 202325 C.84
080SP1 170801 E.32 099E14220 181734 E.65 115PD15210L 132541 G.18 39012Y20D 244107 C.84
080SP12 170808 E.32 099E14250 181735 E.65 115PD15210LT 132551 G.18 39012Y220D 202326 C.84
080SP12SF 170858 E.32 099E14260R 181736 E.65 115PD15210T 132531 G.18 39012Y230D 211706 C.84
080SP12SF 170858 E.68 099E1430 181730 E.65 115PD215210 132524 G.18 39012Y24D 202327 C.84
080SP12SFC 170856 E.32 099E1440 181731 E.65 115PD215210L 132544 G.18 39012Y40D 244106 C.84
080SP12SFC 170856 E.68 099E1460 181732 E.65 115PD215210LT 132554 G.18 39012Y48D 244734 C.84
080SP12SFE 170857 E.32 099E5,512 181641 E.65 115PD215210T 132534 G.18 39012Y97D 202328 C.84
080SP18 170809 E.32 099E5,524 181642 E.65 115PD238350 132525 G.18 3903Y110D 202437 C.84
080SP18SF 170861 E.32 099E5,56 181640 E.65 115PD238350L 132545 G.18 3903Y125D 216100 C.84
080SP18SF 170861 E.68 099SPDTDB 180009 E.67 115PD238350LT 132555 G.18 3903Y197D 214442 C.84
080SP18SFC 170859 E.32 101... 115PD238350T 132535 G.18 3903Y20D 215278 C.84
080SP18SFC 170859 E.68 101 TNC 132099 E.83 115PD2970 132523 G.18 3903Y220D 202438 C.84
080SP18SFE 170860 E.32 101FPMG1 132153 E.83 115PD2970L 132543 G.18 3903Y230D 211107 C.84
080SP1M 170831 E.32 101FPMG2 132163 E.83 115PD2970LT 132553 G.18 3903Y24D 244735 C.84
080SP1MSF 170840 E.32 101FPMN1 132150 E.83 115PD2970T 132533 G.18 3903Y40D 244088 C.84
080SP1MSF 170840 E.68 101FPMN2 132160 E.83 115PD38350 132522 G.18 3903Y48D 212705 C.84
080SP1MSFC 170838 E.32 101FPMR1 132151 E.83 115PD38350L 132542 G.18 3903Y97D 213691 C.84
080SP1MSFC
080SP1MSFE
170838
170839
E.68
E.32
101FPMR2
101FPMV1
132161
132152
E.83
E.83
115PD38350LT
115PD38350T
132552
132532
G.18
G.18
3904Y110D
3904Y125D
202479
202480
C.84
C.84
A
080SP1SF 170837 E.32 101FPMV2 132162 E.83 115PD970 132520 G.18 3904Y197D 202481 C.84
080SP1SF 170837 E.68 101PMG1 132003 E.83 115PD970L 132540 G.18 3904Y20D 244084 C.84
080SP1SFC 170835 E.32 101PMG11 132013 E.83 115PD970LT 132550 G.18 3904Y220D 202482 C.84
080SP1SFC
080SP1SFE
170835
170836
E.68
E.32
101PMG22
101PMN1
132023
132000
E.83
E.83
115PD970T
390...
132530 G.18 3904Y230D
3904Y24D
211708
202483
C.84
C.84
B
080SP2 170802 E.32 101PMN11 132010 E.83 390/3921/2FOM4/2 214120 C.85 3904Y40D 244083 C.84
080SP24 170810 E.32 101PMN22 132020 E.83 390/3921PFRN 244173 C.85 3904Y48D 213814 C.84
080SP24SFE 170862 E.32 101PMR1 132001 E.83 390/3921PFZCS14 202273 C.85 3904Y97D 213601 C.84
080SP2M
080SP2MSF
170832
170846
E.32
E.32
101PMR11
101PMR22
132011
132021
E.83
E.83
390/3921PFZCS25
390/3921PFZCS45
244172
202274
C.85
C.85
3905Y110D
3905Y125D
202512
242260
C.84
C.84
C
080SP2MSF 170846 E.68 101PMV1 132002 E.83 390/3921PMRN 202275 C.85 3905Y197D 244074 C.84
080SP2MSFC 170844 E.32 101PMV11 132012 E.83 390/3921PMZI 202276 C.85 3905Y20D 244073 C.84
080SP2MSFC 170844 E.68 101PMV22 132022 E.83 390/3921PZ 202277 C.85 3905Y220D 212706 C.84
080SP2MSFE
080SP2SF
170845
170843
E.32
E.32
105...
105 CI 132242 E.89
390/3922FOM5/2
390/3922PFRN
214121
212709
C.85
C.85
3905Y230D
3905Y24D
211709
244072
C.84
C.84
D
080SP2SF 170843 E.68 105 CI 10 132243 E.89 390/3922PFZCS45 244744 C.85 3905Y40D 244071 C.84
080SP2SFC 170841 E.32 105 GIL 132240 E.89 390/3922PFZCS90 202278 C.85 3905Y48D 244736 C.84
080SP2SFC 170841 E.68 105 GIL 10 132241 E.89 390/3922PMRN 213014 C.85 3905Y97D 202513 C.84
080SP2SFE
080SP3
170842
170803
E.32
E.32
105 PM
105 PT
132244
132234
E.89
E.88
390/3922PMZI
390/3922PZ
202279
202280
C.85
C.85
3906Y110D
3906Y125D
202532
211711
C.84
C.84
E
080SP35 170811 E.32 105DTL220 132230 E.88 390/3923/2FOM4/2 214122 C.85 3906Y197D 244066 C.84
080SP35SF 170865 E.32 105DTL500 132231 E.88 390/3923FOM5/2 214123 C.85 3906Y20D 244065 C.84
080SP35SF 170865 E.68 105DTL690 132232 E.88 390/3923PFRN 213986 C.85 3906Y220D 213612 C.84
080SP35SFC
080SP35SFC
170863
170863
E.32
E.68
105GP1P220
105GP1P220M
132250
132251
E.88
E.88
390/3923PFZCS125
390/3923PFZCS75
202281
244745
C.85
C.85
3906Y230D
3906Y24D
211770
244064
C.84
C.84
F
080SP35SFE 170864 E.32 105GP1P500 132252 E.88 390/3923PMRN 202282 C.85 3906Y40D 244063 C.84
080SP3SF 170849 E.32 105GP1P500M 132253 E.88 390/3923PMZI 202283 C.85 3906Y48D 212707 C.84
080SP3SF 170849 E.68 105PT 132234 G.9 390/3923PZ 202284 C.85 3906Y97D 202533 C.84
080SP3SFC
080SP3SFC
170847
170847
E.32
E.68
114...
114FCT03 130320 E.88
390/3924F4
390/3924F5/2
214124
204178
C.85
C.85
3907Y110D
3907Y125D
202547
211713
C.84
C.84
G
080SP3SFE 170848 E.32 114FCT03 130320 G.9 390/3924M4/2 214126 C.85 3907Y197D 244059 C.84
080SP4 170804 E.32 114FCT03T 130321 E.88 390/3924M5/2 214127 C.85 3907Y20D 244058 C.84
080SP4M 170834 E.32 114FCT03T 130321 G.9 390/3924PFRN 202287 C.85 3907Y220D 202548 C.84
080SP4MSFE
080SP4SFE
170851
170850
E.32
E.32
114FCT12
114FCT12T
200909
212693
G.9
G.9
390/3924PFZCS125
390/3924PFZCS200
202288
202289
C.85
C.85
3907Y230D
3907Y24D
211712
244057
C.84
C.84
H
080SP6 170806 E.32 114FCT21 200910 G.9 390/3924PMRN 202290 C.85 3907Y40D 244056 C.84
080SP6SFE 170852 E.32 114FCT21T 200911 G.9 390/3924PMZI 202291 C.85 3907Y48D 244737 C.84
080SP8 170807 E.32 114FCT30 200912 G.9 390/3924PZ 202292 C.85 3907Y97D 244738 C.84
080SP8SF
080SP8SF
170855
170855
E.32
E.68
114FCT30T
115...
215422 G.9 390/3925F4/2
390/3925F5/2
214128
214129
C.85
C.85
3908/9M4/2
3908/9M5/2
214141
214142
C.86
C.86
I
080SP8SFC 170853 E.32 1158029-01GI 132566 G.19 390/3925M4/2 214130 C.85 3908F4/2 214144 C.86
080SP8SFC 170853 E.68 1158029-02GI 132567 G.19 390/3925M5/2 214131 C.85 3908F5/2 214145 C.86
080SP8SFE 170854 E.32 1158029-03GIT 132568 G.19 390/3925PFRN 244746 C.85 3908PFZCS400 202555 C.86
080XTG8
080XTG801
179515
179535
E.39
E.39
1158029-04GIT
115803SP
132569
132563
G.19
G.19
390/3925PFZCS150
390/3925PFZCS320
213573
202295
C.85
C.85
3908PFZCS800
3908PMZ
202562
202563
C.86
C.86
X
080XTG802 179536 E.39 115804SP 132565 G.19 390/3925PMRN 202297 C.85 3908PZ 202564 C.86
080XTG803 179511 E.39 115805SP 132564 G.19 390/3925PMZI 202298 C.85 3908Y110D 202565 C.84
080XTG804 179537 E.39 1158065SPA 215320 G.19 390/3925PZ 202299 C.85 3908Y197D 214066 C.84
080XTG805 179538 E.39 1158067SPA 215321 G.19 390/3926F4/2 214133 C.85 3908Y220D 202566 C.84
080XTG806 179539 E.39 115807SP 132562 G.19 390/3926F5/2 214134 C.85 3908Y97D 212959 C.84
080XTG807 179540 E.39 115CA 132571 G.19 390/3926M4/2 214135 C.85 3909F4/2 204179 C.86
080XTG808 179541 E.39 115MA 132570 G.19 390/3926M5/2 214136 C.85 3909F5/2 204180 C.86
080XTGR 179514 E.39 115PC002 132500 G.18 390/3926PFZCS270 202303 C.85 3909PFZCS120 244983 C.86

X.15
Control and Automation
Cat. no Ref. no. Page Cat. no Ref. no. Page Cat. no Ref. no. Page Cat. no Ref. no. Page
3909PMZ 212962 C.86 ACR27A0H75 129995 H.12 BA9SN110 187860 E.38 C...
3909Y110D 202572 C.84 ACR27A0H75 129995 H.35 BA9SN110 187860 E.65 C09476 104766 C.21
3909Y197D 204181 C.84 ACR300A0H067 129705 H.35 BA9SN110 187860 G.19 C09479 204800 C.21
3909Y220D 244739 C.84 ACR35A0H27 129984 H.12 BA9SN220 187861 E.38 CM1CA5F 105200 C.21
3909Y97D 214146 C.84 ACR35A0H27 129984 H.35 BA9SN220 187861 E.65 COMP 480-100 414388 H.43
6... ACR35A0H58 129996 H.35 BCLF01 104701 A.23 COMP 480-130 414389 H.43
6KAVI43001Y1 _ _ 414251 H.42 ACR360A0H056 129706 H.35 BCLF01 104701 C.15 COMP 480-180 414390 H.43
6KAVI43002Y1 _ _ 414252 H.42 ACR38A0H58 129997 H.35 BCLF01G 104703 A.23 COMP 480-42 414385 H.43
6KAVI43003Y1 _ _ 414253 H.42 ACR3A7H0 129788 H.4 BCLF01G 104703 C.15 COMP 480-55 414386 H.43
6KAVI43005Y1 _ _ 414254 H.42 ACR3A8H1 129989 H.4 BCLF10 104700 A.23 COMP 480-75 414387 H.43
6KAVI43007Y1 _ _ 414255 H.42 ACR3A8H1 129989 H.12 BCLF10 104700 C.15 COMP 520-100 414403 H.43
6KAVI43010Y1 _ _ 414256 H.42 ACR3A8H1 129989 H.12 BCLF10G 104702 A.23 COMP 520-130 414404 H.43
By catalogue number

6KAVI43015Y1 _ _ 414257 H.42 ACR3ABH1 129989 H.35 BCLF10G 104702 C.15 COMP 520-16 414398 H.43
6KAVI43020Y1 _ _ 414258 H.42 ACR45A0H45 129998 H.35 BCLL11 104707 C.15 COMP 520-180 414405 H.43
6KAVI43025X1 _ _ 414264 H.42 ACR460A0H056 129707 H.35 BCLL11 104707 C.20 COMP 520-30 414399 H.43
6KAVI43025Y1 _ _ 414259 H.42 ACR4A2H5 129978 H.12 BCLL20 104706 C.15 COMP 520-42 414400 H.43
6KAVI43030X1 _ _ 414265 H.42 ACR4A2H5 129978 H.35 BCLL20 104706 C.20 COMP 520-55 414401 H.43
6KAVI43030Y1 _ _ 414260 H.42 ACR4A5H1 129990 H.4 BCRF01 108902 A.23 COMP 520-7 414397 H.43
6KAVI43040X1 _ _ 414266 H.42 ACR4A5H1 129990 H.12 BCRF01 108902 C.15 COMP 520-75 414402 H.43
6KAVI43040Y1 _ _ 414261 H.42 ACR4A5H1 129990 H.35 BCRF10 108901 A.23 D...
6KAVI43050X1 _ _ 414267 H.42 ACR550A0H039 129708 H.35 BCRF10 108901 C.15 DCR100A0H24 168375 H.36
6KAVI43050Y1 _ _ 414262 H.42 ACR55A0H18 129985 H.35 BEKH 104763 C.21 DCR100A0H49 168286 H.36
6KAVI43060X1 _ _ 414268 H.42 ACR625A0H035 129709 H.35 BEKV 104764 C.21 DCR120A0H2 168376 H.36
6KAVI43060Y1 _ _ 414263 H.42 ACR6A2H5 129979 H.4 BEKVA 1 104785 C.21 DCR125A0H40 168287 H.36
6KAVI43075X1 _ _ 414269 H.42 ACR6A2H5 129979 H.12 BEKVS 1 104786 C.21 DCR12A1H7 168390 H.12
6KAVI43100X1 _ _ 414270 H.42 ACR6A2H5 129979 H.35 BELA 104723 A.24 DCR140A0H32 168288 H.36
6KAVI43125X1 _ _ 414271 H.42 ACR6A3H4 129991 H.4 BELA 104723 C.15 DCR150A017 168377 H.36
6KAVI43150X1 _ _ 414272 H.42 ACR6A3H4 129991 H.12 BELA02 104724 A.24 DCR180A0H14 168378 H.36
6KAVI43200X1 _ _ 414273 H.42 ACR6A3H4 129991 H.35 BELA02 104724 C.15 DCR180A0H25 168289 H.36
6KAVI43F75Y1 _ _ 414250 H.42 ACR700A0H035 168285 H.35 BETL02C 113602 A.25 DCR18A1H0 168391 H.12
6KBU-300-20 414460 H.42 ACR70A0H14 129986 H.35 BETL02C 113602 C.16 DCR18A2H9 168380 H.12
6KBU-300-50 414141 H.42 ACR70A0H29 129928 H.35 BETL02D 113604 A.25 DCR18A2H9 168380 H.36
6KBU-300-85 414095 H.42 ACR80A0H14 129987 H.35 BETL02D 113604 C.16 DCR210A0H25 168290 H.36
A 6KCV300CTI
6KCV301D14A4
414038
414334
H.42
H.42
ACR8A2H5
ACR8A2H5
129791
129791
H.4
H.12
BETL45C
BETL45C
113603
113603
A.25
C.16
DCR220AH11
DCR25A2H1
168379
168381
H.36
H.12
6KCV301D20A6 414335 H.42 ACR8A2H5 129791 H.12 BETL45D 113605 A.25 DCR25A2H1 168381 H.36
6KCV301D8R4 414333 H.42 ACR90A0H22 129700 H.35 BETL45D 113605 C.16 DCR270A0H18 168291 H.36
6KCV301DGF 414343 H.42 ACR97A0H11 129988 H.35 BMLF 104800 D.19 DCR310A0H14 168292 H.36
B 6KCV301DNET
6KCV301ENC
414352
414158
H.42
H.42
ACR9A1H3
ACR9A1H3
129980
129980
H.4
H.12
BNL
BRLL02
104797
106622
D.19
C.15
DCR32A0H78
DCR32A0H78
168371
168371
H.12
H.36
6KCV301KPDMK 414332 H.42 ACR9A1H3 129980 H.35 BRLL02 106622 C.20 DCR32A1H6 168382 H.12
6KCV301PDP33 414066 H.42 B... BRLL11 104705 A.23 DCR32A1H6 168382 H.36
6KCV8S8F59 414371 H.42 BA15D1155 222351 E.79 BRLL11 104705 C.15 DCR3A15H2 168392 H.12
C A...
ACFR10A 168471 H.37
BA15D115LA
BA15D115LB
222337
222341
E.79
E.79
BRLL11
BRLL20
104705
104704
C.20
A.23
DCR400A0H13
DCR40A1H2
168293
168383
H.36
H.36
ACFR115A 168480 H.37 BA15D115LG 222338 E.79 BRLL20 104704 C.15 DCR45A0H55 168372 H.12
ACFR14A 168472 H.37 BA15D115LL 222340 E.79 BRLL20 104704 C.20 DCR45A0H55 168372 H.36
ACFR160A 168481 H.37 BA15D115LR 222336 E.79 BSLDZ 104719 A.24 DCR4A5H7 168387 H.12
D ACFR185A
ACFR18A
168482
168473
H.37
H.37
BA15D115LV
BA15D125
222339
222348
E.79
E.79
BSLDZ
BSLR2G
104719
104713
C.16
A.24
DCR4A9H2
DCR50A0H96
168393
168384
H.12
H.36
ACFR225A 168483 H.37 BA15D2305 222352 E.79 BSLR2G 104713 C.16 DCR540A0H08 168294 H.36
ACFR27A 168474 H.37 BA15D230LA 222343 E.79 BSLR2K 104714 A.24 DCR60A0H4 168373 H.36
ACFR300A 168484 H.37 BA15D230LB 222347 E.79 BSLR2K 104714 C.16 DCR60A0H82 168385 H.36
E ACFR35A
ACFR360A
168475
168485
H.37
H.37
BA15D230LG
BA15D230LL
222344
222346
E.79
E.79
BSLR2R
BSLR2R
104715
104715
A.24
C.16
DCR650A0H07
DCR6A3H9
168295
168388
H.36
H.12
ACFR38A 168476 H.37 BA15D230LR 222342 E.79 BSLR3G 104716 C.16 DCR6A6H8 168394 H.12
ACFR45A 168477 H.37 BA15D230LV 222345 E.79 BSLR3G 104716 C.21 DCR740A0H06 168296 H.36
ACFR460A 168486 H.37 BA15D245 222349 E.79 BSLR3K 104717 C.16 DCR800A0H06 168297 H.36
F ACFR550A
ACFR625A
168487
168488
H.37
H.37
BA15D24LA
BA15D24LB
222331
222335
E.79
E.79
BSLR3K
BSLR3R
104717
104718
C.21
C.16
DCR80A0H3
DCR80A0H58
168374
168386
H.36
H.36
ACFR62A 168478 H.37 BA15D24LG 222332 E.79 BSLR3R 104718 C.21 DCR9A2H4 168389 H.12
ACFR700A 168489 H.37 BA15D24LL 222334 E.79 BSLV3G 104720 A.24 DCR9A4H0 168395 H.12
ACFR90A 168479 H.37 BA15D24LR 222330 E.79 BSLV3G 104720 C.16 DINIL 02E ENU 123656 F.7
G ACR10A2H
ACR10A2H
129992
129992
H.12
H.35
BA15D24LV
BA15D305
222333
222350
E.79
E.79
BSLV3K
BSLV3K
104721
104721
A.24
C.16
DINIL 03E ENU
E...
123666 F.7

ACR115A0H18 129701 H.35 BA9S122 187852 E.38 BSLV3R 104722 A.24 EAT 260 100548 A.20
ACR12A0H84 129981 H.12 BA9S122 187852 E.65 BSLV3R 104722 C.16 EAT 260 100548 A.24
ACR12A0H84 129981 H.35 BA9S122 187852 G.19 BSLV3U 110836 A.24 EAT 260 100548 C.8
H ACR12A2H5
ACR12A2H5
129792
129792
H.4
H.12
BA9S130
BA9S130
187857
187857
E.38
E.65
BSLV3U
BSLV3U
110836
110836
C.16
C.21
EAT 260
EAT 260
100548
100548
C.17
C.61
ACR140A0H072 129925 H.35 BA9S130 187857 G.19 BTLF30C 104709 A.23 EMI-FFP 480-24 414382 H.43
ACR14A1H4 129993 H.12 BA9S242 187853 E.38 BTLF30C 104709 C.15 EMI-FFP 480-30 414383 H.43
ACR14A1H4 129993 H.35 BA9S242 187853 E.65 BTLF30D 104711 A.23 EMI-FFP 480-9 414381 H.43
I ACR160A0H14
ACR180A0H056
129702
129926
H.35
H.35
BA9S242
BA9S30
187853
187854
G.19
E.38
BTLF30D
BTLF60C
104711
104710
C.15
A.23
EPL
ERN00K7
104798
129148
D.19
H.12
ACR185A0H11 129703 H.35 BA9S30 187854 E.65 BTLF60C 104710 C.15 ERN00K7 129148 H.13
ACR18A0H56 129982 H.12 BA9S30 187854 G.19 BTLF60D 104712 A.23 ERN01K5 129149 H.12
ACR18A0H56 129982 H.35 BA9S48 187855 E.38 BTLF60D 104712 C.15 ERN01K5 129149 H.13
X ACR18A1H1
ACR18A1H1
129994
129994
H.12
H.35
BA9S48
BA9S48
187855
187855
E.65
G.19
BTLFX
BTLFX
113001
113001
A.23
C.15
ERN02K2
ERN02K2
129150
129150
H.12
H.13
ACR18A1H3 129793 H.4 BA9S6012 187856 E.38 BTRF30C 108903 A.23 ERN04K0 129151 H.12
ACR18A1H3 129793 H.12 BA9S6012 187856 E.65 BTRF30C 108903 C.15 ERN04K0 129151 H.13
ACR200A0H051 129927 H.35 BA9S6012 187856 G.19 BTRF30D 108905 A.23 ERN05K5 129152 H.12
ACR225A0H096 129704 H.35 BA9S606 187850 E.38 BTRF30D 108905 C.15 ERN05K5 129152 H.13
ACR22A0H84 129794 H.4 BA9S606 187850 E.65 BTRF60C 108904 A.23 ERN07K5 129153 H.12
ACR22A0H84 129794 H.12 BA9S615 187851 E.38 BTRF60C 108904 C.15 ERN07K5 129153 H.13
ACR27A0H37 129983 H.12 BA9S615 187851 E.65 BTRF60D 108906 A.23 ERX00K7 129154 H.12
ACR27A0H37 129983 H.35 BA9S615 187851 G.19 BTRF60D 108906 C.15 ERX00K7 219154 H.13

X.16
Control and Automation
Cat. no Ref. no. Page Cat. no Ref. no. Page Cat. no Ref. no. Page Cat. no Ref. no. Page
ERX01K5 129155 H.12 GPB1B12A 101394 B.19 GPF2L45DA 101416 D.3 GPS2BSAL 107119 B.11
ERX01K5 129155 H.13 GPB1B13A 101395 B.19 GPF3B5A 107253 D.3 GPS2BSAM 101227 B.11
ERX02K2 129156 H.12 GPB1B14A 101396 B.19 GPF3L09AA 107252 D.3 GPS2BSAN 101228 B.11
ERX02K2 129156 H.13 GPB1B15A 101397 B.19 GPS1BHAA 101234 B.9 GPS2BSAP 101229 B.11
ERX04K0 129157 H.12 GPB1B22A 101398 B.19 GPS1BHAB 101235 B.9 GPS2BSAR 101230 B.11
ERX04K0 129157 H.13 GPB1B24A 101399 B.19 GPS1BHAC 101236 B.9 GPS2BSAS 101231 B.11
ERX05K5 129158 H.12 GPB1FA 107186 B.19 GPS1BHAD 101237 B.9 GPS2BSAT 101232 B.11
ERX05K5 129158 H.13 GPB1GA 101408 B.5 GPS1BHAE 101238 B.9 GPS2BSAU 101233 B.11
ERX07K5 129159 H.12 GPB1GA 101408 B.19 GPS1BHAF 101239 B.9 GPS2MHAK 101295 B.15
ERX07K5 129159 H.13 GPB1GAF 101511 B.19 GPS1BHAG 101240 B.9 GPS2MHAL 107122 B.15
G... GPB2B02A 101400 B.19 GPS1BHAH 101241 B.9 GPS2MHAM 101296 B.15
GPA1HAB 101363 B.19 GPB2B03A 101401 B.19 GPS1BHAJ 101242 B.9 GPS2MHAN 101297 B.15

By catalogue number
GPA1HAR 101364 B.19 GPB2B04A 101402 B.19 GPS1BHAK 101243 B.9 GPS2MHAP 101298 B.15
GPA2HAB 101502 B.19 GPB2B12A 101403 B.19 GPS1BHAL 101244 B.9 GPS2MHAR 101299 B.15
GPA2HAR 101503 B.19 GPB2B13A 101404 B.19 GPS1BHAM 101245 B.9 GPS2MHAS 101300 B.15
GPAC01FBA 101304 B.17 GPB2B14A 101405 B.19 GPS1BHAN 101246 B.9 GPS2MHAT 101301 B.15
GPAC02LLA 101307 B.17 GPB2B22A 101406 B.19 GPS1BHAP 101247 B.9 GPS2MHAU 101302 B.15
GPAC02LRA 101310 B.17 GPB2B24A 101407 B.19 GPS1BHAR 101248 B.9 GPS2MSAK 101272 B.15
GPAC10FBA 101303 B.17 GPB2FA 107187 B.19 GPS1BSAA 101211 B.9 GPS2MSAL 107121 B.15
GPAC11LLA 101305 B.17 GPB2GA 101409 B.19 GPS1BSAAMP 101195 B.9 GPS2MSAM 101273 B.15
GPAC11LRA 101308 B.17 GPECA 101371 B.21 GPS1BSAB 101212 B.9 GPS2MSAN 101274 B.15
GPAC20LLA 101306 B.17 GPEF41A 101367 B.21 GPS1BSABMP 101196 B.9 GPS2MSAP 101275 B.15
GPAC20LRA 101309 B.17 GPEF55A 101368 B.21 GPS1BSAC 101213 B.9 GPS2MSAR 101276 B.15
GPAD0101LLA 101316 B.17 GPELCAJ 101385 B.4 GPS1BSACMP 101197 B.9 GPS2MSAS 101277 B.15
GPAD0110LLA 101315 B.17 GPELCAJ 101385 B.21 GPS1BSAD 101214 B.9 GPS2MSAT 101278 B.15
GPAD1001LLA 101314 B.17 GPELCAN 101386 B.4 GPS1BSADMP 101198 B.9 GPS2MSAU 101279 B.15
GPAD1010LLA 101313 B.17 GPELCAN 101386 B.21 GPS1BSAE 101215 B.9 GPVDA 101514 B.18
GPAE11LLA 101317 B.17 GPELCAU 101387 B.4 GPS1BSAEMP 101199 B.9 GPVPA 101515 B.18
GPAKS1A 101509 B.18 GPELCAU 101387 B.21 GPS1BSAF 101216 B.9 H...
GPAL01FRA 101312 B.17 GPELCAX 101388 B.4 GPS1BSAFMP 101200 B.9 HE300GEN250 414353 H.42
GPAL10FRA 101311 B.17 GPELCAX 101388 B.21 GPS1BSAG 101217 B.9 I...
GPAPT1E 107315 B.19 GPELCAY 101389 B.4 GPS1BSAGMP 101201 B.9 IMAMS 113611 A.25
GPAPTP2A 107182 B.18 GPELCAY 101389 B.21 GPS1BSAH 101218 B.9 IMAMS 113611 C.16
GPASLRAA1
GPASLRAA11
101318
101194
B.18
B.18
GPELGAJ
GPELGAJ
101375
101375
B.4
B.21
GPS1BSAHMP
GPS1BSAJ
101202
101219
B.9
B.9
IMD1Z
IMD1Z
113595
113595
A.25
C.16
A
GPASLRAAF 101319 B.18 GPELGAN 101376 B.4 GPS1BSAJMP 101203 B.9 IMGA-B211 130001 G.3
GPASLRAAG 101320 B.18 GPELGAN 101376 B.21 GPS1BSAK 101220 B.9 IMGA-B411 130019 G.3
GPASLRAAJ 101321 B.18 GPELGAU 101377 B.4 GPS1BSAKMP 101204 B.9 IMGC-B411 130037 G.3
GPASLRAAM
GPASLRAAN
101322
101323
B.18
B.18
GPELGAU
GPELGAX
101377
101378
B.21
B.4
GPS1BSAL
GPS1BSALMP
101221
101205
B.9
B.9
IMGE-B211
IMGE-B411
130009
130027
G.3
G.3
B
GPASLRAAR 101324 B.18 GPELGAX 101378 B.21 GPS1BSAM 101222 B.9 IMGF-B411 130042 G.3
GPASLRAAU 101325 B.18 GPELGAY 101379 B.4 GPS1BSAMMP 101206 B.9 IMGG-B411 130043 G.3
GPASLRAAW 101326 B.18 GPELGAY 101379 B.21 GPS1BSAN 101223 B.9 IMGH-B211 130005 G.3
GPASLRAAY
GPASLRADD
101327
101328
B.18
B.18
GPELRAJ
GPELRAJ
101380
101380
B.4
B.21
GPS1BSANMP
GPS1BSAP
101207
101224
B.9
B.9
IMGH-B411
IMGJ-B211
130023
130007
G.3
G.3
C
GPASLRADJ 101329 B.18 GPELRAN 101381 B.4 GPS1BSAPMP 101208 B.9 IMGJ-B411 130025 G.3
GPAU20LCAA11 112185 B.18 GPELRAN 101381 B.21 GPS1BSAR 101225 B.9 IMGL-B211 130011 G.3
GPAU20LCAAC 101353 B.18 GPELRAU 101382 B.4 GPS1BSARMP 101209 B.9 IMGL-B411 130029 G.3
GPAU20LCAAD
GPAU20LCAAF
101352
101355
B.18
B.18
GPELRAU
GPELRAX
101382
101383
B.21
B.4
GPS1MHAA
GPS1MHAB
101280
101281
B.13
B.13
IMGM-B311
IMGP-B111
130041
130015
G.3
G.3
D
GPAU20LCAAG 101354 B.18 GPELRAX 101383 B.21 GPS1MHAC 101282 B.13 IMGP-B311 130035 G.3
GPAU20LCAAJ 101356 B.18 GPELRAY 101384 B.4 GPS1MHAD 101283 B.13 IMGQ-B111 130017 G.3
GPAU20LCAAM 101357 B.18 GPELRAY 101384 B.21 GPS1MHAE 101284 B.13 IMGQ-B311 130039 G.3
GPAU20LCAAN
GPAU20LCAAR
101358
101359
B.18
B.18
GPENA
GPEPA
101369
101370
B.21
B.21
GPS1MHAF
GPS1MHAG
101285
101286
B.13
B.13
IMGR-B211
IMGR-B411
130003
130021
G.3
G.3
E
GPAU20LCAAU 101360 B.18 GPEPKA 101374 B.21 GPS1MHAH 101287 B.13 IMGT-B111 130013 G.3
GPAU20LCAAW 101361 B.18 GPEPLA 101373 B.21 GPS1MHAJ 101288 B.13 IMGT-B311 130031 G.3
GPAU20LCAAY 101362 B.18 GPEPMA 101372 B.21 GPS1MHAK 101289 B.13 IMGV-B411 130033 G.3
GPAU20LTAA11
GPAU20LTAAC
110360
101342
B.18
B.18
GPES41A
GPES55A
101365
101366
B.21
B.21
GPS1MHAL
GPS1MHAM
101290
101291
B.13
B.13
IMRC2G
IMRC2G
113601
113601
A.25
C.16
F
GPAU20LTAAD 101341 B.18 GPEUTA 107097 B.21 GPS1MHAN 101292 B.13 IMRC2K 113600 A.25
GPAU20LTAAF 101344 B.18 GPF00C02 107098 D.3 GPS1MHAP 101293 B.13 IMRC2K 113600 C.16
GPAU20LTAAG 101343 B.18 GPF00C04 107102 D.3 GPS1MHAR 101294 B.13 IMRC2R 113599 A.25
GPAU20LTAAJ
GPAU20LTAAM
101345
101346
B.18
B.18
GPF00C08
GPF00C25
107107
107101
D.3
D.3
GPS1MSAA
GPS1MSAB
101257
101258
B.13
B.13
IMRC2R
IMRC3G
113599
113598
C.16
C.16
G
GPAU20LTAAN 101347 B.18 GPF00C45 107106 D.3 GPS1MSAC 101259 B.13 IMRC3K 113597 C.16
GPAU20LTAAR 101348 B.18 GPF01C02 107100 D.3 GPS1MSAD 101260 B.13 IMRC3R 113596 C.16
GPAU20LTAAU 101349 B.18 GPF01C04 107105 D.3 GPS1MSAE 101261 B.13 IMRD 113606 A.25
GPAU20LTAAW
GPAU20LTAAY
101350
101351
B.18
B.18
GPF10C02
GPF10C04
107099
107103
D.3
D.3
GPS1MSAF
GPS1MSAG
101262
101263
B.13
B.13
IMRD
IMRFD
113606
113608
C.16
A.25
H
GPAULRAA11 102625 B.18 GPF1B1A 101418 D.3 GPS1MSAH 101264 B.13 IMRFD 113608 C.16
GPAULRAAC 101331 B.18 GPF1B4A 107163 D.3 GPS1MSAJ 101265 B.13 IMRFG 113609 A.25
GPAULRAAD 101330 B.18 GPF1CBA 101427 D.3 GPS1MSAK 101266 B.13 IMRFG 113609 C.16
GPAULRAAF
GPAULRAAG
101333
101332
B.18
B.18
GPF1L02AA
GPF1L02DA
101411
101412
D.3
D.3
GPS1MSAL
GPS1MSAM
101267
101268
B.13
B.13
IMRG
IMRG
113607
113607
A.25
C.16
I
GPAULRAAJ 101334 B.18 GPF1L04AA 107165 D.3 GPS1MSAN 101269 B.13 IMSSD 113610 A.25
GPAULRAAM 101335 B.18 GPF1L04DA 107166 D.3 GPS1MSAP 101270 B.13 IMSSD 113610 C.16
GPAULRAAN 101336 B.18 GPF1L25AA 101413 D.3 GPS1MSAR 101271 B.13 IMV3G 113594 A.25
GPAULRAAR
GPAULRAAU
101337
101338
B.18
B.18
GPF1L25CT1
GPF1L25DA
101512
101414
D.3
D.3
GPS2BHAK
GPS2BHAL
101249
107120
B.11
B.11
IMV3G
IMV3K
113594
113593
C.16
A.25
X
GPAULRAAW 101339 B.18 GPF1L45CT1 101513 D.3 GPS2BHAM 101250 B.11 IMV3K 113593 C.16
GPAULRAAY 101340 B.18 GPF1LMCBA 101410 D.3 GPS2BHAN 101251 B.11 IMV3R 113592 A.25
GPB104A 101392 B.5 GPF2B2A 101419 D.3 GPS2BHAP 101252 B.11 IMV3R 113592 C.16
GPB105A 101393 B.5 GPF2B3A 101420 D.3 GPS2BHAR 101253 B.11 IPA1-D222B 132185 E.85
GPB1B02A 101390 B.19 GPF2L04AA 107190 D.3 GPS2BHAS 101254 B.11 IPA1-D422B 132214 E.85
GPB1B03A 101391 B.19 GPF2L04DA 107191 D.3 GPS2BHAT 101255 B.11 IPA1-N211B 132170 E.85
GPB1B04A 101392 B.19 GPF2L07AA 101417 D.3 GPS2BHAU 101256 B.11 IPA1-N222B 132184 E.85
GPB1B05A 101393 B.19 GPF2L45AA 101415 D.3 GPS2BSAK 101226 B.11 IPA1-N411B 132198 E.85

X.17
Control and Automation
Cat. no Ref. no. Page Cat. no Ref. no. Page Cat. no Ref. no. Page Cat. no Ref. no. Page
IPA1-N422B 132213 E.85 IUGR-B411 130086 G.5 MARF431AF 100504 A.18 MG0004RAT0 137567 D.19
IPA1-P211B 132171 E.85 IUGT-B111 130076 G.5 MARF431AF 100504 C.6 MG0006PAT0 209781 D.19
IPA1-R411B 132200 E.85 IUGT-B311 130098 G.5 MARF440AF 100503 A.18 MG0006QAT0 116074 D.19
IPA2-D222B 132189 E.85 IUGU-B211 130062 G.5 MARF440AF 100503 C.6 MG0006RAT0 116402 D.19
IPA2-D422B 132218 E.85 IUGU-B411 130084 G.5 MARL101AF 100516 A.19 MMH0 100547 A.20
IPA2-N211B 132174 E.85 IZMA-B211 130140 G.6 MARL101AFS 100522 A.19 MMH0 100547 C.8
IPA2-N222B 132188 E.85 IZMA-B311 130144 G.6 MARL101AFS 100522 C.7 MP0AAE1 100544 A.20
IPA2-N411B 132204 E.85 IZMH-B211 130143 G.6 MARL101AI 100518 A.19 MP0AAE1 100544 C.8
IPA2-N422B 132217 E.85 IZMH-B311 130147 G.6 MARL101AIS 100524 A.19 MP0AAE2 100545 A.20
IPA2-P211B 132175 E.85 IZMR-B211 130142 G.6 MARL101AIS 100524 C.7 MP0AAE2 100545 C.8
IPB1-D222B 132187 E.85 IZMR-B311 130146 G.6 MARL101AR 103557 A.19 MP0CAE3 100546 A.20
IPB1-D422B 132216 E.85 IZMS-B211 130141 G.6 MARL101ARS 103298 A.19 MP0CAE3 100546 C.8
By catalogue number

IPB1-N211B 132172 E.85 IZMS-B311 130145 G.6 MARL101ARS 103298 C.7 MP0DAE4 100536 A.20
IPB1-N222B 132186 E.85 K... MARL101AT 100514 A.19 MP0DAE4 100536 C.8
IPB1-N411B 132201 E.85 KRC24 104760 C.21 MARL101ATS 100520 A.19 MRD-100AN 122084 F.3
IPB1-N422B 132215 E.85 KRC380/415 104762 C.21 MARL101ATS 100520 C.7 MRD-10AN 122064 F.3
IPB1-P211B 132173 E.85 KRC48/260 104761 C.21 MARL110AF 100515 A.19 MRD-50AN 122074 F.3
IPB1-R411B 132203 E.85 KVB10E 104597 D.23 MARL110AFS 100521 A.19 MRD-5AN 122054 F.3
IPB2-D222B 132191 E.85 KVB10I 104692 D.21 MARL110AFS 100521 C.7 MRD-700AN 122094 F.3
IPB2-D422B 132220 E.85 KVB12E 104587 D.23 MARL110AI 100517 A.19 MREBC10AC2 100541 A.20
IPB2-N211B 132176 E.85 KVB12I 104693 D.21 MARL110AIS 100523 A.19 MREBC10AC2 100541 C.8
IPB2-N222B 132190 E.85 KVB75E 104694 D.23 MARL110AIS 100523 C.7 MREBC20AC2 100542 A.20
IPB2-N411B 132206 E.85 KVB75I 104690 D.21 MARL110AR 103556 A.19 MREBC20AC2 100542 C.8
IPB2-N422B 132219 E.85 KVB95E 104695 D.23 MARL110ARS 103299 A.19 MT03A 101000 C.61
IPB2-P211B 132177 E.85 KVB95I 104691 D.21 MARL110ARS 103299 C.7 MT03B 101001 C.61
IPSF1 223000 E.86 KVP08E 116212 D.23 MARL110AT 100513 A.19 MT03C 101002 C.61
ISGA-B211 130000 G.3 KVP10E 133380 D.23 MARL110ATS 100519 A.19 MT03D 101003 C.61
ISGA-B411 130018 G.3 KVP10G 104771 D.19 MARL110ATS 100519 C.7 MT03E 101004 C.61
ISGC-B411 130036 G.3 KVP10I 133371 D.21 MARN202AR 103351 A.18 MT03F 101005 C.61
ISGE-B211 130008 G.3 KVP10U 133374 D.21 MARN202AR 103351 C.6 MT03G 101006 C.61
ISGE-B411 130026 G.3 KVP12E 116235 D.23 MARN202AT 100992 A.18 MT03H 101007 C.61
ISGH-B211 130004 G.3 KVP12G 104767 D.19 MARN202AT 100992 C.6 MT03I 101008 C.61
ISGH-B411 130022 G.3 KVP12I 113633 D.21 MARN211AR 103350 A.18 MT03J 101009 C.61
A ISGJ-B211
ISGJ-B411
130006
130024
G.3
G.3
KVP12U
KVP75E
113630
133378
D.21
D.23
MARN211AR
MARN211AT
103350
100993
C.6
A.18
MT03K
MT03L
101010
101011
C.61
C.61
ISGL-B211 130010 G.3 KVP75I 133370 D.21 MARN211AT 100993 C.6 MT03M 101012 C.61
ISGL-B411 130028 G.3 KVP75U 113627 D.21 MARN220AR 103349 A.18 MT03N 101013 C.61
ISGM-B311 130040 G.3 KVP85E 133379 D.23 MARN220AR 103349 C.6 MT03P 101014 C.61
B ISGP-B111
ISGP-B311
130014
130034
G.3
G.3
KVP85G
KVP85I
104770
113631
D.19
D.21
MARN220AT
MARN220AT
100994
100994
A.18
C.6
MT03R
MT03RA
101015
103540
C.61
C.61
ISGQ-B111 130016 G.3 KVP85U 113628 D.21 MARN404AR 103300 A.18 MT03RB 103541 C.61
ISGQ-B311 130038 G.3 KVP95E 113637 D.23 MARN404AR 103300 C.6 MT03RC 103542 C.61
ISGR-B211 130002 G.3 L... MARN404AT 100987 A.18 MT03RD 103543 C.61
C ISGR-B411
ISGT-B111
130020
130012
G.3
G.3
LG0004P1B0
LG0004R1B0
209344
116651
D.19
D.19
MARN404AT
MARN413AR
100987
103355
C.6
A.18
MT03RE
MT03RF
103544
103545
C.61
C.61
ISGT-B311 130030 G.3 LG0004S1B0 209347 D.19 MARN413AR 103355 C.6 MT03RG 103546 C.61
ISGV-B411 130032 G.3 LG0006P1B0 200004 D.19 MARN413AT 100988 A.18 MT03RH 103547 C.61
IUCA-B211 130061 G.5 LG0006R1B0 116652 D.19 MARN413AT 100988 C.6 MT03RI 103548 C.61
D IUCA-B411
IUCE-B211
130083
130073
G.5
G.5
LG0006S1B0
LG0404P1B0
116011
116653
D.19
D.19
MARN422AR
MARN422AR
103354
103354
A.18
C.6
MT03RJ
MT03RK
103549
103550
C.61
C.61
IUCE-B411 130095 G.5 LG0404R1B0 133264 D.19 MARN422AT 100989 A.18 MT03RL 103551 C.61
IUCH-B211 130067 G.5 LG0404S1B0 116996 D.19 MARN422AT 100989 C.6 MT03RM 103552 C.61
IUCH-B411 130089 G.5 LG0406P1B0 116656 D.19 MARN431AR 103353 A.18 MT03RN 103553 C.61
E IUCI-B211
IUCI-B411
130069
130091
G.5
G.5
LG0406R1B0
LG0406S1B0
133265
116997
D.19
D.19
MARN431AR
MARN431AT
103353
100990
C.6
A.18
MT03RP
MTCAN
103554
122004
C.61
F.3
IUCL-B211 130075 G.5 LG2504P1B0 100885 D.19 MARN431AT 100990 C.6 MVB0R 100543 A.20
IUCL-B411 130097 G.5 LG2504R1B0 116226 D.19 MARN440AR 103352 A.18 MVB0R 100543 C.8
IUCM-B311 130105 G.5 LG2506P1B0 101095 D.19 MARN440AR 103352 C.6 MVB0T 101021 C.61
F IUCP-B111
IUCP-B311
130079
130101
G.5
G.5
LG2506R1B0
M...
133611 D.19 MARN440AT
MARN440AT
100991
100991
A.18
C.6
MVE0R
MVE0T
103562
101020
C.61
C.61
IUCQ-B111 130081 G.5 MACF413AF 100557 C.6 MATV10AR 103563 C.61 MVP0C 100600 C.8
IUCQ-B311 130103 G.5 MACF422AF 100556 C.6 MATV10AT 101022 C.61 N...
IUCR-B211 130065 G.5 MACF431AF 100555 C.6 MB0ID 100470 A.17 N11P3401806 168260 H.37
G IUCR-B411
IUCT-B111
130087
130077
G.5
G.5
MACL101AF
MACL101AI
100563
100565
C.7
C.7
MB0ID
MB0KD
100470
100471
C.4
A.17
N11P3401807
NLT1A
168261
222231
H.37
E.78
IUCT-B311 130099 G.5 MACL101AR 103556 C.7 MB0KD 100471 C.4 NLT1G 222232 E.78
IUCU-B211 130063 G.5 MACL101AT 100561 C.7 MC0I301ATD 100571 C.4 NLT1I 222235 E.78
IUCU-B411 130085 G.5 MACL110AF 100562 C.7 MC0I310ATD 100570 C.4 NLT1L 222234 E.78
H IUGA-B211
IUGA-B411
130060
130082
G.5
G.5
MACL110AI
MACL110AR
100564
103555
C.7
C.7
MC0K301ATD
MC0K310ATD
100575
100574
C.4
C.4
NLT1R
NLT1V
222230
222233
E.78
E.78
IUGE-B211 130072 G.5 MACL110AT 100560 C.7 MC1I301ATD 100573 C.4 NLT2AJA 222243 E.78
IUGE-B411 130094 G.5 MACN202AR 103558 C.6 MC1I310ATD 100572 C.4 NLT2AJG 222244 E.78
IUGH-B211 130066 G.5 MACN202AT 100998 C.6 MC1K301ATD 100577 C.4 NLT2AJI 222247 E.78
I IUGH-B411
IUGI-B211
130088
130068
G.5
G.5
MACN211AR
MACN211AT
103557
100999
C.6
C.6
MC1K310ATD
MC2I301ATD
100576
100538
C.4
C.4
NLT2AJL
NLT2AJLA
222246
222296
E.78
E.78
IUGI-B411 130090 G.5 MACN413AR 103561 C.6 MC2I310ATD 100559 C.4 NLT2AJLG 222297 E.78
IUGJ-B211 130071 G.5 MACN413AT 100995 C.6 MC2K301ATD 103591 C.4 NLT2AJLI 242464 E.78
IUGJ-B411 130093 G.5 MACN422AR 103560 C.6 MC2K310ATD 103590 C.4 NLT2AJLL 222299 E.78
X IUGK-B211
IUGK-B411
130070
130092
G.5
G.5
MACN422AT
MACN431AR
100996
103559
C.6
C.6
MCRI022ATD
MCRI031ATD
100532
100531
A.17
A.17
NLT2AJLR
NLT2AJLV
222295
222298
E.78
E.78
IUGL-B211 130074 G.5 MACN431AT 100997 C.6 MCRI040ATD 100530 A.17 NLT2AJR 222242 E.78
IUGL-B411 130096 G.5 MAGL110AT 100608 D.19 MCRK022ATD 100535 A.17 NLT2AJV 222245 E.78
IUGM-B311 130104 G.5 MARF404AF 100507 A.18 MCRK031ATD 100534 A.17 NLT2ANA 222249 E.78
IUGP-B111 130078 G.5 MARF404AF 100507 C.6 MCRK040ATD 100533 A.17 NLT2ANG 222250 E.78
IUGP-B311 130100 G.5 MARF413AF 100506 A.18 MET t AN 122045 F.3 NLT2ANI 222253 E.78
IUGQ-B111 130080 G.5 MARF413AF 100506 C.6 METAN 122034 F.3 NLT2ANL 222252 E.78
IUGQ-B311 130102 G.5 MARF422AF 100505 A.18 MG0004PAT0 209780 D.19 NLT2ANLA 222302 E.78
IUGR-B211 130064 G.5 MARF422AF 100505 C.6 MG0004QAT0 137566 D.19 NLT2ANLG 222303 E.78

X.18
Control and Automation
Cat. no Ref. no. Page Cat. no Ref. no. Page Cat. no Ref. no. Page Cat. no Ref. no. Page
NLT2ANLI 222306 E.78 P9ACPBS215 188215 E.39 P9ARBGV 014 187124 E.34 P9ARDPL030 187368 E.35
NLT2ANLL 222305 E.78 P9ACPBS222 188222 E.39 P9ARBGV 017 187126 E.34 P9ARDPL031 187363 E.35
NLT2ANLR 222301 E.78 P9ACPBS224 188224 E.39 P9ARBGV 018 187128 E.34 P9ARDPL032 187364 E.35
NLT2ANLV 222304 E.78 P9ACPBS231 188231 E.39 P9ARBGV 026 187130 E.34 P9ARDPL035 187353 E.35
NLT2ANR 222248 E.78 P9ACPBS232 188232 E.39 P9ARBGV 027 187132 E.34 P9ARDPL038 187354 E.35
NLT2ANV 222251 E.78 P9ACPBS233 188233 E.39 P9ARBGV 028 187112 E.34 P9ARDPL201 187369 E.35
NLT2BDA 222237 E.78 P9ACPBS234 188234 E.39 P9ARBGV 030 187146 E.34 P9ARDPL202 187370 E.35
NLT2BDG 222238 E.78 P9ACPBS239 188239 E.39 P9ARBGV 031 187134 E.34 P9ARHPR 187491 E.37
NLT2BDI 222241 E.78 P9ACPBS243 188243 E.39 P9ARBGV 032 187136 E.34 P9ARPBM 188002 E.39
NLT2BDL 222240 E.78 P9ACPBS258 188258 E.39 P9ARBGV 035 187114 E.34 P9ARPTM 188019 E.39
NLT2BDLA 222290 E.78 P9ACPBS301 188301 E.39 P9ARBGV 038 187116 E.34 P9ARPWM 188028 E.39
NLT2BDLG 222291 E.78 P9ACPBS302 188302 E.39 P9ARBGV 202 187149 E.34 P9ARRE4 187492 E.37

By catalogue number
NLT2BDLI 222294 E.78 P9ACPBS303 188303 E.39 P9ARBSB 006 187252 E.34 P9ARSN1 188805 E.37
NLT2BDLL 222293 E.78 P9ACPBS304 188304 E.39 P9ARBSB 028 187251 E.34 P9ARTBM 188001 E.38
NLT2BDLR 222289 E.78 P9ACPBS305 188305 E.39 P9ARBSB 202 188978 E.34 P9ARTBS 188000 E.38
NLT2BDLV 222292 E.78 P9ACPBS306 188306 E.39 P9ARBSN 001 187237 E.34 P9ARTTM 188019 E.38
NLT2BDR 222236 E.78 P9ACPBS307 188307 E.39 P9ARBSN 002 187239 E.34 P9ARTTS 188012 E.38
NLT2BDV 222239 E.78 P9ACPBS308 188308 E.39 P9ARBSN 005 187241 E.34 P9ARTWM 188008 E.38
NLT3AJA 222261 E.78 P9ACPBS309 188309 E.39 P9ARBSN 006 187217 E.34 P9ARTWS 188005 E.38
NLT3AJG 222262 E.78 P9ACPBS316 188316 E.39 P9ARBSN 012 187219 E.34 P9ASBGB 006 187552 E.34
NLT3AJI 222265 E.78 P9ACPBS317 188317 E.39 P9ARBSN 013 187221 E.34 P9ASBGB 028 187551 E.34
NLT3AJL 222264 E.78 P9ACPBS324 188324 E.39 P9ARBSN 014 187223 E.34 P9ASBGB 202 189859 E.34
NLT3AJR 222260 E.78 P9ACPBS328 188328 E.39 P9ARBSN 017 187225 E.34 P9ASBGL 037 187543 E.34
NLT3AJV 222263 E.78 P9ACPBS331 188331 E.39 P9ARBSN 018 187227 E.34 P9ASBGN 001 187537 E.34
NLT3ANA 222267 E.78 P9ACPBS332 188332 E.39 P9ARBSN 026 187229 E.34 P9ASBGN 002 187539 E.34
NLT3ANG 222268 E.78 P9ACPBS333 188333 E.39 P9ARBSN 027 187231 E.34 P9ASBGN 005 187541 E.34
NLT3ANI 222271 E.78 P9ACPBS334 188334 E.39 P9ARBSN 028 187211 E.34 P9ASBGN 006 187517 E.34
NLT3ANL 222270 E.78 P9ACPBS335 188335 E.39 P9ARBSN 029 187250 E.34 P9ASBGN 012 187519 E.34
NLT3ANR 222266 E.78 P9ACPBS336 188336 E.39 P9ARBSN 030 187245 E.34 P9ASBGN 013 187521 E.34
NLT3ANV 222269 E.78 P9ACPIU 188016 E.39 P9ARBSN 031 187233 E.34 P9ASBGN 014 187523 E.34
NLT3BDA 222255 E.78 P9ACPTS 188018 E.39 P9ARBSN 032 187235 E.34 P9ASBGN 017 187525 E.34
NLT3BDG 222256 E.78 P9ACPWS 188017 E.39 P9ARBSN 035 187213 E.34 P9ASBGN 018 187527 E.34
NLT3BDI 222259 E.78 P9ACRCL 187840 E.37 P9ARBSN 038 187215 E.34 P9ASBGN 026 187529 E.34
NLT3BDL
NLT3BDR
222258
222254
E.78
E.78
P9ACVLR
P9ACWAF
187844
187845
E.37
E.37
P9ARBSN 202
P9ARBSR 029
187248
187210
E.34
E.34
P9ASBGN 027
P9ASBGN 028
187531
187511
E.34
E.34
A
NLT3BDV 222257 E.78 P9ADCST 187796 E.21 P9ARBSR 201 187247 E.34 P9ASBGN 029 187550 E.34
NLT4BDA 222273 E.78 P9AELN 189030 E.28 P9ARBSV 001 187238 E.34 P9ASBGN 030 187545 E.34
NLT4BDG 222274 E.78 P9AELN006 189041 E.28 P9ARBSV 002 187240 E.34 P9ASBGN 031 187533 E.34
NLT4BDI
NLT4BDL
222277
222276
E.78
E.78
P9AELN028
P9AELN029
189042
189043
E.28
E.28
P9ARBSV 005
P9ARBSV 006
187242
187218
E.34
E.34
P9ASBGN 032
P9ASBGN 035
187535
187513
E.34
E.34
B
NLT4BDR 222272 E.78 P9AELN035 189044 E.28 P9ARBSV 012 187220 E.34 P9ASBGN 036 187553 E.34
NLT4BDV 222275 E.78 P9AELN038 189045 E.28 P9ARBSV 013 187222 E.34 P9ASBGN 038 187515 E.34
NLT5BT 222284 E.79 P9AELN039 189046 E.28 P9ARBSV 014 187224 E.34 P9ASBGN 202 187548 E.34
NLT5ET
NLT73BD
222285
222278
E.79
E.79
P9AELN042
P9AELN201
189047
189032
E.28
E.28
P9ARBSV 017
P9ARBSV 018
187226
187228
E.34
E.34
P9ASBGR 029
P9ASBGR 036
187510
187544
E.34
E.34
C
NLT75AJ 222287 E.79 P9AELN202 189031 E.28 P9ARBSV 026 187230 E.34 P9ASBGR 201 187547 E.34
NLT75AN 222288 E.79 P9AELN203 189038 E.28 P9ARBSV 027 187232 E.34 P9ASBGV 001 187538 E.34
NLT75BD 222286 E.79 P9AELN204 189037 E.28 P9ARBSV 028 187212 E.34 P9ASBGV 002 187540 E.34
NLT77AJ
NLT77AN
222280
222281
E.79
E.79
P9AELN205
P9AELN206
189035
189036
E.28
E.28
P9ARBSV 030
P9ARBSV 031
187246
187234
E.34
E.34
P9ASBGV 005
P9ASBGV 006
187542
187518
E.34
E.34
D
NLT77BD 222279 E.79 P9AELN214 189033 E.28 P9ARBSV 032 187236 E.34 P9ASBGV 012 187520 E.34
NLT90BT 222307 E.79 P9AELN215 189034 E.28 P9ARBSV 035 187214 E.34 P9ASBGV 013 187522 E.34
NLT9TC 222282 E.79 P9AELN222 189152 E.28 P9ARBSV 038 187216 E.34 P9ASBGV 014 187524 E.34
NMETV
NMICV
124908
124907
F.4
F.4
P9AELN224
P9AEMT
189154
189029
E.28
E.28
P9ARBSV 202
P9ARCST
187249
187490
E.34
E.36
P9ASBGV 017
P9ASBGV 018
187526
187528
E.34
E.34
E
NMIFV 124928 F.5 P9ARBGB 006 187152 E.34 P9ARDLS001 187315 E.35 P9ASBGV 026 187530 E.34
NMIVV 124929 F.5 P9ARBGB 028 187151 E.34 P9ARDLS002 187316 E.35 P9ASBGV 027 187532 E.34
NMMFV 124930 F.5 P9ARBGB 202 188909 E.34 P9ARDLS005 187317 E.35 P9ASBGV 028 187512 E.34
NMRDV 2-6
NMRDV 2-60
124915
124916
F.5
F.5
P9ARBGL 037
P9ARBGN 001
187143
187137
E.34
E.34
P9ARDLS006
P9ARDLS012
187305
187306
E.35
E.35
P9ASBGV 030
P9ASBGV 031
187546
187534
E.34
E.34
F
NMRDV 2-600 124917 F.5 P9ARBGN 002 187139 E.34 P9ARDLS013 187307 E.35 P9ASBGV 032 187536 E.34
NMRDV-6 124912 F.5 P9ARBGN 005 187141 E.34 P9ARDLS014 187308 E.35 P9ASBGV 035 187514 E.34
NMRDV-60 124913 F.5 P9ARBGN 006 187117 E.34 P9ARDLS017 187309 E.35 P9ASBGV 038 187516 E.34
NMRDV-600
NMTCIV
124914
124905
F.5
F.4
P9ARBGN 012
P9ARBGN 013
187119
187121
E.34
E.34
P9ARDLS018
P9ARDLS026
187310
187311
E.35
E.35
P9ASBGV 202
P9ASBSB 006
187549
187652
E.34
E.34
G
NMTCSV 124906 F.4 P9ARBGN 014 187123 E.34 P9ARDLS027 187312 E.35 P9ASBSB 028 187651 E.34
NMTCV 124900 F.4 P9ARBGN 017 187125 E.34 P9ARDLS028 187302 E.35 P9ASBSB 202 189928 E.34
NMTCV 2 124901 F.4 P9ARBGN 018 187127 E.34 P9ARDLS029 187301 E.35 P9ASBSL 037 187643 E.34
NMTDV
P...
124927 F.5 P9ARBGN 026
P9ARBGN 027
187129
187131
E.34
E.34
P9ARDLS030
P9ARDLS031
187318
187313
E.35
E.35
P9ASBSN 001
P9ASBSN 002
187637
187639
E.34
E.34
H
P9ACA6 188804 E.22 P9ARBGN 028 187111 E.34 P9ARDLS032 187314 E.35 P9ASBSN 005 187641 E.34
P9ACAFV 187847 E.37 P9ARBGN 029 187150 E.34 P9ARDLS035 187303 E.35 P9ASBSN 006 187617 E.34
P9ACDPP 187843 E.37 P9ARBGN 030 187145 E.34 P9ARDLS038 187304 E.35 P9ASBSN 012 187619 E.34
P9ACFS3
P9ACFS5
187841
187842
E.37
E.37
P9ARBGN 031
P9ARBGN 032
187133
187135
E.34
E.34
P9ARDLS201
P9ARDLS202
187319
187320
E.35
E.35
P9ASBSN 013
P9ASBSN 014
187621
187623
E.34
E.34
I
P9ACFSM 187846 E.22 P9ARBGN 035 187113 E.34 P9ARDPL001 187365 E.35 P9ASBSN 017 187625 E.34
P9ACFSM 187846 E.37 P9ARBGN 036 187153 E.34 P9ARDPL002 187366 E.35 P9ASBSN 018 187627 E.34
P9ACPBS 188015 E.39 P9ARBGN 038 187115 E.34 P9ARDPL005 187367 E.35 P9ASBSN 026 187629 E.34
P9ACPBS039
P9ACPBS201
188030
188201
E.39
E.39
P9ARBGN 202
P9ARBGR 029
187148
187110
E.34
E.34
P9ARDPL006
P9ARDPL012
187355
187356
E.35
E.35
P9ASBSN 027
P9ASBSN 028
187631
187611
E.34
E.34
X
P9ACPBS202 188202 E.39 P9ARBGR 036 187144 E.34 P9ARDPL013 187357 E.35 P9ASBSN 029 187650 E.34
P9ACPBS203 188203 E.39 P9ARBGR 201 187147 E.34 P9ARDPL014 187358 E.35 P9ASBSN 030 187645 E.34
P9ACPBS204 188204 E.39 P9ARBGV 001 187138 E.34 P9ARDPL017 187359 E.35 P9ASBSN 031 187633 E.34
P9ACPBS205 188205 E.39 P9ARBGV 002 187140 E.34 P9ARDPL018 187360 E.35 P9ASBSN 032 187635 E.34
P9ACPBS206 188206 E.39 P9ARBGV 005 187142 E.34 P9ARDPL026 187361 E.35 P9ASBSN 035 187613 E.34
P9ACPBS207 188207 E.39 P9ARBGV 006 187118 E.34 P9ARDPL027 187362 E.35 P9ASBSN 038 187615 E.34
P9ACPBS208 188208 E.39 P9ARBGV 012 187120 E.34 P9ARDPL028 187352 E.35 P9ASBSN 202 187648 E.34
P9ACPBS214 188214 E.39 P9ARBGV 013 187122 E.34 P9ARDPL029 187351 E.35 P9ASBSR 029 187610 E.34

X.19
Control and Automation
Cat. no Ref. no. Page Cat. no Ref. no. Page Cat. no Ref. no. Page Cat. no Ref. no. Page
P9ASBSR 201 187647 E.34 P9MCC 184697 E.19 P9SER4RA 186072 E.13 P9YER4RA 185921 E.25
P9ASBSV 001 187638 E.34 P9MCD 184695 E.19 P9SET4R 186061 E.13 P9YSCD0A95 185970 E.26
P9ASBSV 002 187640 E.34 P9MEC53130 153130 E.10 P9SET4RL1 186561 E.18 P9YSCD0K95 185972 E.26
P9ASBSV 005 187642 E.34 P9MEM53111 153111 E.10 P9SRG 186771 E.20 P9YSCZ0C95 185784 E.26
P9ASBSV 006 187618 E.34 P9MEM53112 153112 E.10 P9SSCD0A95 186400 E.16 P9YSCZ0T95 185980 E.26
P9ASBSV 012 187620 E.34 P9MER3RN 184070 E.13 P9SSCD0K95 186402 E.16 P9YSCZ3C95 185987 E.26
P9ASBSV 013 187622 E.34 P9MER4RN 184071 E.13 P9SSCD5A95 186409 E.16 P9YSMD0N 185960 E.26
P9ASBSV 014 187624 E.34 P9MER53161 153161 E.10 P9SSCI0C95 186403 E.16 P9YSMZ0N 185962 E.26
P9ASBSV 017 187626 E.34 P9MET53121 153121 E.10 P9SSCI0N95 186405 E.16 P9YSMZ3N 185965 E.26
P9ASBSV 018 187628 E.34 P9MLD53610 153610 E.11 P9SSCI5C95 186410 E.16 P9ZSCD0A95 186970 E.26
P9ASBSV 026 187630 E.34 P9MLD53611 153611 E.11 P9SSCZ0T95 186439 E.16 P9ZSCD0K95 186972 E.26
P9ASBSV 027 187632 E.34 P9MLD53612 153612 E.11 P9SSCZ3C95 186467 E.17 P9ZSCZ0C95 186975 E.26
By catalogue number

P9ASBSV 028 187612 E.34 P9MLD53613 153613 E.11 P9SSCZ5A95 186461 E.17 P9ZSCZ0T95 186980 E.26
P9ASBSV 030 187646 E.34 P9MLD53614 153614 E.11 P9SSMD5N 186140 E.14 P9ZSCZ3C95 186987 E.26
P9ASBSV 031 187634 E.34 P9MLD53620 153623 E.11 P9SSME0N 186170 E.14 P9ZSMD0N 186960 E.26
P9ASBSV 032 187636 E.34 P9MLD53621 153621 E.11 P9SSME1N 186210 E.14 P9ZSMZ0N 186962 E.26
P9ASBSV 035 187614 E.34 P9MLD53622 153622 E.11 P9SSMI0N 186120 E.14 P9ZSMZ3N 186965 E.26
P9ASBSV 038 187616 E.34 P9MMB2A 184712 E.19 P9SSMI5N 186150 E.14 PBF13EBCA 107146 D.4
P9ASBSV 202 187649 E.34 P9MMB2B 184713 E.19 P9SSMU0N 186190 E.14 PBF13EBDA 107147 D.4
P9ASCGT 170790 E.36 P9MMB2F 184710 E.19 P9SSMU1N 186230 E.14 PBF13ECBA 107138 D.4
P9ASCST 187791 E.36 P9MMB2T 184711 E.19 P9SSMW0N 186360 E.14 PBF13ECDA 107148 D.4
P9ASEBG 187795 E.37 P9MMB4F 184740 E.19 P9SSMX0N 186330 E.14 PBF13FCBA 107139 D.4
P9ASHAC 187794 E.37 P9MMB4T 184741 E.19 P9SSMZ1N 186240 E.14 PBF13FDBA 107140 D.4
P9ASHP3 187792 E.37 P9MMN2A 184702 E.19 P9SSMZ3N 186320 E.14 PBF13FDEA 107149 D.4
P9ASHP5 187793 E.37 P9MMN2B 184703 E.19 P9SSMZ5N 186280 E.14 PBF13GDFA 107150 D.4
P9ASTBS 188010 E.38 P9MMN2F 184700 E.19 P9SZ 186772 E.20 PBF1AAAPA 107380 D.4
P9ASTTS 188014 E.38 P9MMN2T 184701 E.19 P9XBD 185773 E.20 PBF23EBCA 107151 D.4
P9ASTWS 188011 E.38 P9MMN4F 184720 E.19 P9XBM 185774 E.20 PBF23EBDA 107152 D.4
P9B01BN 187017 E.27 P9MMN4T 184721 E.19 P9XCB 185696 E.19 PBF23ECBA 107142 D.4
P9B01FH 187014 E.22 P9MPL53502 153501 E.11 P9XCC 185697 E.19 PBF23ECDA 107153 D.4
P9B01FN 187012 E.22 P9MPL53511 153511 E.11 P9XCD 185695 E.19 PBF23FCBA 107143 D.4
P9B01VN 187001 E.22 P9MPL53513 153513 E.11 P9XEC52130 152130 E.10 PBF23FDBA 107145 D.4
P9B01VN 187001 E.67 P9MPL53514 153514 E.11 P9XEM52111 152111 E.10 PBF23FDEA 107155 D.4
A P9B01VR
P9B02VN
187003
187008
E.22
E.22
P9MPL53515
P9MPL53530
153515
153530
E.11
E.11
P9XEM52112
P9XER3RN
152112
185070
E.10
E.13
PBF23GDFA
PBF2AAAQA
107156
107381
D.4
D.4
P9B10BN 187018 E.27 P9MPL53531 153531 E.11 P9XER4RA 185072 E.13 PBF2AAARA 107383 D.4
P9B10FH 187015 E.22 P9MPL53561 153561 E.11 P9XER4RN 185071 E.13 PBF2AEAHA 107157 D.4
P9B10FN 187013 E.22 P9MPN53006 153006 E.10 P9XER52161 152161 E.10 PBF2AFAHA 107158 D.4
B P9B10VA
P9B10VN
187004
187002
E.22
E.22
P9MPN53007
P9MPN53008
153007
153008
E.10
E.10
P9XER52170
P9XET52121
152170
152121
E.10
E.10
PBF2AGAHA
PBFAAAAMA
107159
107161
D.4
D.4
P9B10VN 187002 E.67 P9MPN53009 153009 E.10 P9XLD52610 152610 E.11 PBFAAAANA 107162 D.4
P9B11T3 187010 E.22 P9MPN53010 153010 E.10 P9XLD52611 152611 E.11 PBFAABALA 107160 D.4
P9B11T8 187011 E.22 P9MPN53011 153011 E.10 P9XLD52612 152612 E.11 PBFCAFAN-A 107382 D.4
C P9B11VN
P9B11VN
187000
187000
E.22
E.67
P9MPN53012
P9MPN53061
153012
153061
E.10
E.10
P9XLD52613
P9XLD52614
152613
152614
E.11
E.11
PCP12G
PR3110STD
241749
167978
D.19
H.33
P9B20VN 187009 E.22 P9MPS21G 184690 E.19 P9XLD52620 152620 E.11 PR3120STD 167979 H.33
P9DPL54700 154700 E.11 P9MPS22G 184691 E.19 P9XLD52621 152621 E.11 PR3150STD 167980 H.33
P9DPL54701 154701 E.11 P9MPS23G 184692 E.19 P9XLD52622 152622 E.11 PR3180STD 167981 H.33
D P9DPL54720
P9DPL54721
154720
154721
E.11
E.11
P9MPS34G
P9MPS35G
184693
184694
E.19
E.19
P9XMB2A
P9XMB2B
185712
185713
E.19
E.19
PR3280STD
PR3330STD
167982
167983
H.33
H.33
P9DPLNRG00 186880 E.21 P9MRG 184771 E.20 P9XMB2F 185710 E.19 PR3380STD 167984 H.33
P9DPLNRG01 186890 E.21 P9MSC53435 153435 E.10 P9XMB2T 185711 E.19 PR3450STD 167985 H.33
P9DPLNRS00 186882 E.21 P9MSC53436 153436 E.10 P9XMB4F 185740 E.19 PR3600STD 167986 H.33
E P9DPLNRS01
P9DPLVRG00
186892
186881
E.21
E.21
P9MSC53497
P9MSC53498
153497
153498
E.10
E.10
P9XMB4T
P9XMN2A
185741
185702
E.19
E.19
PR3750STD
PR3900STD
167987
167988
H.33
H.33
P9DPLVRG01 186891 E.21 P9MSM53293 153293 E.10 P9XMN2B 185703 E.19 PRC1S13ANL 222012 A.5
P9DPLVRS00 186883 E.21 P9MSM53391 153391 E.10 P9XMN2F 185700 E.19 PRC1S13BDL 222004 A.5
P9DPLVRS01 186893 E.21 P9MSM53392 153392 E.10 P9XMN2T 185701 E.19 PRC1S13BNL 222013 A.5
F P9EPA01Y02
P9EPA01Y02
189010
189144
E.28
E.28
P9MSM53393
P9MWR
153393
184770
E.10
E.20
P9XMN4F
P9XMN4T
185720
185721
E.19
E.19
PRC1S13CBL
PRC1S13CDL
222007
222008
A.5
A.5
P9EPA01Y03 189011 E.28 P9MZ 184772 E.20 P9XPL52502 152502 E.11 PRC1T10ADL 221868 A.5
P9EPA01Y04 189012 E.28 P9PDHF 187056 E.22 P9XPL52511 152511 E.11 PRC1T10AJL 221869 A.5
P9EPA01Y05 189013 E.28 P9PDHF 187056 E.23 P9XPL52513 152513 E.11 PRC1T10ANL 221870 A.5
G P9EPA01Y06
P9EPA02Y01
189014
189016
E.28
E.29
P9PDMVD
P9PDMVJ
187040
187041
E.23
E.23
P9XPL52514
P9XPL52515
152514
152515
E.11
E.11
PRC1T10CBL
PRC1T10CDL
221860
221861
A.5
A.5
P9EPA02Y02 189017 E.29 P9PDNB0 187070 E.27 P9XPL52530 152530 E.11 PRC1T10CJL 221862 A.5
P9EPA03Y01 189018 E.29 P9PDNF0 187055 E.23 P9XPL52531 152531 E.11 PRC1T20ADL 221883 A.5
P9EPA03Y02 189019 E.29 P9PDNV0 187020 E.23 P9XPL52561 152561 E.11 PRC1T20AJL 221884 A.5
H P9EPA03Y03
P9EPA03Y04
189020
189021
E.29
E.29
P9PDTV0
P9PRDBN
187027
187072
E.23
E.27
P9XPN52002
P9XPN52007
152002
152007
E.10
E.10
PRC1T20ANL
PRC1T20CBL
221885
221875
A.5
A.5
P9EPA03Y05 189022 E.29 P9PRDVN 187022 E.23 P9XPN52008 152008 E.10 PRC1T20CDL 221876 A.5
P9EPA06Y01 189023 E.29 P9PREVJ 187025 E.23 P9XPN52009 152009 E.10 PRC1T20CJL 221877 A.5
P9EPAG1Y01 189015 E.28 P9PREVL 187026 E.23 P9XPN52010 152010 E.10 PRC2P20ABL 220019 A.4
I P9EPC01X00
P9EPC01X01
215432
215433
E.30
E.30
P9PRLBJ
P9PRLVJ
187071
187021
E.27
E.23
P9XPN52011
P9XPN52012
152011
152012
E.10
E.10
PRC2P20ADL
PRC2P20AGL
220020
220021
A.4
A.4
P9EPE01 189001 E.28 P9PRNBJ 187073 E.27 P9XPN52061 152061 E.10 PRC2P20AJL 220024 A.4
P9EPE02 189002 E.28 P9PRNBN 187074 E.27 P9XRG 185771 E.20 PRC2P20ANL 220026 A.4
P9EPE03 189003 E.28 P9PRNVJ 187023 E.23 P9XSC52435 152435 E.10 PRC2P20CBL 220022 A.4
X P9EPE04
P9EPE06
189004
189005
E.28
E.28
P9PRNVN
P9PRTVN
187024
187028
E.23
E.23
P9XSC52436
P9XSC52497
152436
152497
E.10
E.10
PRC2P20CDL
PRC2P20CGL
220023
220025
A.4
A.4
P9EPEG1 189000 E.28 P9SBD 186773 E.20 P9XSC52498 152498 E.10 PRC2P20CJL 220027 A.4
P9EPL02X01 189136 E.30 P9SBM 186774 E.20 P9XSM52293 152293 E.10 PRC2P20DCBL 220041 A.4
P9EPL02X02 189137 E.30 P9SCB 186696 E.19 P9XSM52391 152321 E.10 PRC2P20DCDL 220042 A.4
P9EPL03X01 189138 E.30 P9SCC 186697 E.19 P9XSM52392 152392 E.10 PRC2P20DCGL 220043 A.4
P9EPL03X02 189138 E.30 P9SCD 186695 E.19 P9XSM52393 152393 E.10 PRC2P20DCJL 220044 A.4
P9EPL03X03 189140 E.30 P9SEC4RA95 186073 E.13 P9XWR 185770 E.20 PRC3P30ABL 220310 A.4
P9EPL04X01 189141 E.31 P9SEM3R 186031 E.13 P9XZ 185772 E.20 PRC3P30ADL 220311 A.4
P9MCB 184696 E.19 P9SEM3RL 186551 E.18 P9YEM4RN 185920 E.25 PRC3P30AGL 220312 A.4

X.20
Control and Automation
Cat. no Ref. no. Page Cat. no Ref. no. Page Cat. no Ref. no. Page Cat. no Ref. no. Page
PRC3P30AJL 220315 A.4 PRCTR 221921 A.5 QS2HNA 120469 D.73 RT1RJ 114093 C.63
PRC3P30ANL 220317 A.4 PRCTR1 220916 A.3 QS2INA 120471 D.73 RT1RK 114094 C.63
PRC3P30CBL 220313 A.4 PRCTR1S 222043 A.5 R... RT1RL 114095 C.63
PRC3P30CDL 220314 A.4 PRCW20 222039 A.5 RANGER 520-280 414391 H.43 RT1RM 114096 C.63
PRC3P30CGL 220316 A.4 PRCZ11 220647 A.4 RANGER 520-450 414392 H.43 RT1RN 114097 C.63
PRC3P30CJL 220318 A.4 PRCZ11 220647 F.7 RCR 1AJ 123603 F.6 RT1RP 114098 C.63
PRC3P30DCBL 220335 A.4 PRCZ8 220216 A.4 RCR 1EN 123604 F.6 RT1RS 114099 C.63
PRC3P30DCDL 220336 A.4 PTP04 113850 C.17 RDMT1-50AN 124044 F.9 RT1RT 114100 C.63
PRC3P30DCGL 220337 A.4 PTP08 113852 C.17 RDMT1-50AU 124045 F.9 RT1RU 114101 C.63
PRC3P30DCJL 220338 A.4 PTP10 113853 C.17 RET 50ENU 122534 F.6 RT1RV 114102 C.63
PRC4M20ABL 220710 A.3 PTP45 113851 C.17 RSS13/64TA10 211742 C.84 RT1RW 114103 C.63
PRC4M20ADL 220711 A.3 PTPCK11 103749 C.21 RSS13/64TA100 211743 C.84 RT1S 113712 C.63

By catalogue number
PRC4M20AGL 220712 A.3 PTPCK75 103747 C.21 RSS13/64TA120 243281 C.84 RT1T 113713 C.63
PRC4M20AJL 220715 A.3 PTPCK75 103747 C.65 RSS13/64TA1200 213034 C.84 RT1U 113714 C.63
PRC4M20ANL 220717 A.3 PTPCK95 103748 C.21 RSS13/64TA15 211737 C.84 RT1V 113715 C.63
PRC4M20CBL 220713 A.3 PVP10G 241748 D.19 RSS13/64TA18 211727 C.84 RT1W 113716 C.63
PRC4M20CDL 220714 A.3 PVP85G 241747 D.19 RSS13/64TA180 211744 C.84 RT22D 113650 C.63
PRC4M20CGL 220716 A.3 Q... RSS13/64TA220 212702 C.84 RT22E 113651 C.63
PRC4M20CJL 220718 A.3 QA02P008S 120881 D.67 RSS13/64TA27 244192 C.84 RT22G 113652 C.63
PRC4M20DCBL 220754 A.3 QA02P017S 120882 D.67 RSS13/64TA270 214399 C.84 RT22H 113653 C.63
PRC4M20DCDL 220755 A.3 QA02P022S 120883 D.67 RSS13/64TA300 211714 C.84 RT22J 113654 C.63
PRC4M20DCGL 220756 A.3 QA02P031S 120884 D.67 RSS13/64TA300 211714 C.84 RT22L 113655 C.63
PRC4M20DCJL 220757 A.3 QA02P044S 120885 D.67 RSS13/64TA33 211728 C.84 RT22M 113656 C.63
PRC4M30ABL 221051 A.3 QA02P058S 120886 D.67 RSS13/64TA330 211745 C.84 RT22RD 114124 C.63
PRC4M30ADL 221052 A.3 QA12P008S 120892 D.67 RSS13/64TA39 211730 C.84 RT22RE 114125 C.63
PRC4M30AGL 221053 A.3 QA12P017S 120893 D.67 RSS13/64TA390 211746 C.84 RT22RG 114126 C.63
PRC4M30AJL 221056 A.3 QA12P022S 120894 D.67 RSS13/64TA47 211731 C.84 RT22RH 114127 C.63
PRC4M30ANL 221058 A.3 QA12P031S 120895 D.67 RSS13/64TA470 244191 C.84 RT22RJ 114128 C.63
PRC4M30CBL 221054 A.3 QA12P044S 120896 D.67 RSS13/64TA5,6 211735 C.84 RT22RL 114129 C.63
PRC4M30CDL 221055 A.3 QA12P058S 120897 D.67 RSS13/64TA6,8 214869 C.84 RT22RM 114130 C.63
PRC4M30CGL 221057 A.3 QA22P008S 120898 D.67 RSS13/64TA680 214580 C.84 RT2A 113717 C.63
PRC4M30CJL 221059 A.3 QA22P017S 120899 D.67 RSS13/64TA8,2 204177 C.84 RT2B 113718 C.63
PRC4M30DCBL 221074 A.3 QA22P022S 120900 D.67 RSS13/64TA820 214400 C.84 RT2C 113719 C.63
PRC4M30DCDL
PRC4M30DCGL
221075
221076
A.3
A.3
QA22P031S
QA22P044S
120901
120902
D.67
D.67
RSS20/165TA100
RSS20/165TA120
213663
213664
C.84
C.84
RT2D
RT2E
113720
113721
C.63
C.63
A
PRC4M30DCJL 221077 A.3 QA22P058S 120903 D.67 RSS20/165TA150 215004 C.84 RT2G 113722 C.63
PRC4M40ABL 221809 A.3 QA32P008S 120904 D.67 RSS20/165TA390 211748 C.84 RT2H 113723 C.63
PRC4M40ADL 221810 A.3 QA32P017S 120905 D.67 RSS20/165TA470 211739 C.84 RT2J 113724 C.63
PRC4M40AGL
PRC4M40AJL
221811
221814
A.3
A.3
QA32P022S
QA32P031S
120906
120907
D.67
D.67
RSS20/165TA560
RSS20/165TA82
244987
214081
C.84
C.84
RT2L
RT2M
113725
113726
C.63
C.63
B
PRC4M40ANL 221816 A.3 QA32P044S 120908 D.67 RT12D 139138 C.63 RT2RA 114104 C.63
PRC4M40CBL 221812 A.3 QA32P058S 120909 D.67 RT12F 139139 C.63 RT2RB 114105 C.63
PRC4M40CDL 221813 A.3 QAOPTDIN 120910 D.67 RT12G 139140 C.63 RT2RC 114106 C.63
PRC4M40CGL
PRC4M40CJL
221815
221817
A.3
A.3
QC1FDP
QC1GDP
129728
129730
D.80
D.80
RT12H
RT12J
139141
139142
C.63
C.63
RT2RD
RT2RE
114107
114108
C.63
C.63
C
PRC4M40DCBL 221851 A.3 QC1HDP 129732 D.80 RT12K 113640 C.63 RT2RG 114109 C.63
PRC4M40DCDL 221852 A.3 QC1IDP 129734 D.80 RT12L 113641 C.63 RT2RH 114110 C.63
PRC4M40DCGL 221853 A.3 QC1JDP 129736 D.80 RT12M 113642 C.63 RT2RJ 114111 C.63
PRC4M40DCJL
PRCG1052
221854
220914
A.3
A.3
QC1KDP
QC1LDP
129738
129740
D.80
D.80
RT12N
RT12P
113643
113644
C.63
C.63
RT2RL
RT2RM
114112
114113
C.63
C.63
D
PRCG11 220648 A.4 QC1MDP 129742 D.80 RT12RD 114060 C.63 RT2XP 113764 C.65
PRCG8 220217 A.4 QC1NDP 129744 D.80 RT12RF 114061 C.63 RT32C 113657 C.64
PRCG-ES15/2N 220912 A.3 QC1QDP 129746 D.80 RT12RG 114062 C.63 RT32D 113658 C.64
PRCG-ES15/3N
PRCG-ES15/4N
221442
221934
A.3
A.3
QC1QDP
QC1RDP
129746
129748
D.80
D.80
RT12RH
RT12RJ
114063
114159
C.63
C.63
RT32E
RT32F
113659
113660
C.64
C.64
E
PRCGZT80 221918 A.5 QC1SDP 129750 D.80 RT12RK 114114 C.63 RT3B 113727 C.64
PRCM21N 222101 A.6 QC1TDP 129752 D.80 RT12RL 114115 C.63 RT3C 113728 C.64
PRCM21P 222100 A.6 QC1UDP 129754 D.80 RT12RM 114116 C.63 RT3D 113729 C.64
PRCM31G
PRCM31R
222104
222102
A.6
A.6
QC1VDP
QC1XDP
129756
129758
D.80
D.80
RT12RN
RT12RP
114117
114118
C.63
C.63
RT3E
RT3F
113730
113731
C.64
C.64
F
PRCM32G 222105 A.6 QC2FDP 129729 D.80 RT12RS 114119 C.63 RT3PXX3P 110565 C.65
PRCM32R 222103 A.6 QC2GDP 129731 D.80 RT12RT 114120 C.63 RT4LA 113735 C.64
PRCM33G 222106 A.6 QC2HDP 129733 D.80 RT12RU 114121 C.63 RT4LB 113736 C.64
PRCM33R
PRCM51
222109
222113
A.6
A.6
QC2IDP
QC2JDP
129735
129737
D.80
D.80
RT12RV
RT12RW
114122
114123
C.63
C.63
RT4LC
RT4LD
113737
113738
C.64
C.64
G
PRCM52 222114 A.6 QC2KDP 129739 D.80 RT12S 113645 C.63 RT4LE 113739 C.64
PRCM53 222115 A.6 QC2LDP 129741 D.80 RT12T 113646 C.63 RT4LF 113740 C.64
PRCM71 222121 A.6 QC2MDP 129743 D.80 RT12U 113647 C.63 RT4LG 113741 C.64
PRCM73
PRCM91G
222122
222126
A.6
A.6
QC2NDP
QC2QDP
129745
129747
D.80
D.80
RT12V
RT12W
113648
113649
C.63
C.63
RT4LH
RT4LJ
113742
113743
C.64
C.64
H
PRCM91R 222116 A.6 QC2RDP 129749 D.80 RT1B 113700 C.63 RT4LK 113744 C.64
PRCM93G 222120 A.6 QC2SDP 129751 D.80 RT1C 113701 C.63 RT4LL 113745 C.64
PRCMS16 221920 A.5 QC2TDP 129753 D.80 RT1D 113702 C.63 RT4LM 113746 C.64
PRCMS35
PRCPZ11
220915
220218
A.3
A.4
QC2UDP
QC2VDP
129755
129757
D.80
D.80
RT1F
RT1G
113703
113704
C.63
C.63
RT4LN
RT4LP
113747
113748
C.64
C.64
I
PRCR159 220219 A.4 QC2XDP 129759 D.80 RT1H 113705 C.63 RT4LR 113749 C.64
PRCT1AD 221896 A.5 QCPDNT 129768 D.80 RT1J 113706 C.63 RT4N 113732 C.64
PRCT1AJ 221897 A.5 QCPPDP 129769 D.80 RT1K 113707 C.63 RT4P 113733 C.64
PRCT1AN
PRCT1CB
221898
221890
A.5
A.5
QS1BNA
QS1DNA
120460
120462
D.73
D.73
RT1L
RT1M
113708
113709
C.63
C.63
RT4R
RT5A
113734
113750
C.64
C.64
X
PRCT1CD 221891 A.5 QS1FNA 120464 D.73 RT1N 113710 C.63 RT5B 113751 C.64
PRCT1CJ 221892 A.5 QS1GNA 120466 D.73 RT1P 113711 C.63 RT5C 113752 C.64
PRCT2AD 221913 A.5 QS1HNA 120468 D.73 RT1RB 114087 C.63 RT5D 113753 C.64
PRCT2AJ 221914 A.5 QS1INA 120470 D.73 RT1RC 114088 C.63 RT5E 113754 C.64
PRCT2AN 221915 A.5 QS2BNA 120461 D.73 RT1RD 114089 C.63 RT5LA 113755 C.64
PRCT2CB 221905 A.5 QS2DNA 120463 D.73 RT1RF 114090 C.63 RT5LB 113756 C.64
PRCT2CD 221906 A.5 QS2FNA 120465 D.73 RT1RG 114091 C.63 RT5LC 113757 C.64
PRCT2CJ 221907 A.5 QS2GNA 120467 D.73 RT1RH 114092 C.63 RT5LD 113758 C.64

X.21
Control and Automation
Cat. no Ref. no. Page Cat. no Ref. no. Page Cat. no Ref. no. Page Cat. no Ref. no. Page
RT5LE 113759 C.64 TLR100P200 108223 H.12 U201N01K5SS 167413 H.12 U20X1K5P 167094 H.7
RT6A 113760 C.64 TLR100P200 108223 H.12 U201N02K2FS 167403 H.9 U20X1K5PS 167138 H.3
RT6LA 113761 C.64 TLR108P200 129869 H.34 U201N02K2FS 167403 H.12 U20X1K5PS 167138 H.7
RTX3 113762 C.65 TLR118P600 129174 H.12 U201N02K2SS 167414 H.9 U20X1K5S 167081 H.3
RTXBS 108864 C.65 TLR118P600 129174 H.34 U201N02K2SS 167414 H.12 U20X1K5S 167081 H.6
RTXP 105170 C.65 TLR11P1200 129170 H.34 U203N00K4SS 167415 H.9 U20X2K2P 167095 H.3
RTXS 113855 C.65 TLR15P1000 129169 H.34 U203N00K4SS 167415 H.12 U20X2K2P 167095 H.7
RTXSL 113856 C.65 TLR15P3700 129881 H.34 U203N00K7SS 167416 H.9 U20X2K2PS 167139 H.3
S... TLR175P600 129173 H.12 U203N00K7SS 167416 H.12 U20X2K2PS 167139 H.7
SBELA 101017 C.15 TLR175P600 129173 H.34 U203N01K5SS 167417 H.9 U20X2K2S 167082 H.3
SFAI11 120024 B.3 TLR18P3000 129880 H.34 U203N01K5SS 167417 H.12 U20X2K2S 167082 H.6
SFAK01 120026 B.3 TLR200P200 129165 H.12 U203N02K2SS 167418 H.9 U2KF3016PR1 167832 H.33
By catalogue number

SFAK10 120025 B.3 TLR216P200 129868 H.34 U203N02K2SS 167418 H.12 U2KF3030PR1 167833 H.33
SFAL11D 120022 B.3 TLR22P2500 129879 H.34 U203N04K0SS 167419 H.9 U2KF3032PR2 167834 H.33
SFAL11N 120020 B.3 TLR22P600 129168 H.12 U203N04K0SS 167419 H.12 U2KF3058PR3 167835 H.33
SFAL11S 120027 B.3 TLR22P600 129168 H.34 U203N05K5SS 167420 H.9 U2KF3060PR2 167836 H.33
SFAL20D 120023 B.3 TLR240P200 108227 H.12 U203N05K5SS 167420 H.12 U2KF3096PR4 167838 H.33
SFAL20N 120021 B.3 TLR240P200 108227 H.12 U203N07K5SS 167422 H.9 U2KF309PRD3 167837 H.33
SFALPEN 264826 B.3 TLR250P200 108227 H.4 U203N07K5SS 167422 H.12 U2KN00K4S 168000 H.16
SFB0AJ 120030 B.3 TLR295P200 129876 H.34 U203X00K7FS 167404 H.9 U2KN00K7S 168001 H.16
SFB0AN 120031 B.3 TLR29P1800 129878 H.34 U203X00K7FS 167404 H.12 U2KN01K5S 168002 H.16
SFB0AU 120032 B.3 TLR29P600 129167 H.12 U203X00K7SS 167424 H.9 U2KN02K2S 168003 H.16
SFB0RJ 120034 B.3 TLR29P600 129167 H.34 U203X00K7SS 167424 H.12 U2KN04K0S 168004 H.16
SFB0RJM 107256 B.3 TLR35P1500 129877 H.34 U203X01K5FS 167405 H.9 U2KN05K5S 168005 H.16
SFB0RN 120035 B.3 TLR400P200 116302 H.4 U203X01K5FS 167405 H.12 U2KN07K5S 168006 H.16
SFB0RNM 120114 B.3 TLR400P200 116302 H.12 U203X01K5SS 167425 H.9 U2KN11K0S 168007 H.16
SFB0RU 120036 B.3 TLR405P200 129867 H.34 U203X01K5SS 167425 H.12 U2KN15K0S 168008 H.16
SFB0RUM 120115 B.3 TLR432P200 129875 H.34 U203X02K2FS 167406 H.9 U2KN18K5S 168009 H.16
SFE04 120042 B.4 TLR43P1000 129177 H.12 U203X02K2FS 167406 H.12 U2KN22K0S 168010 H.16
SFE04K1 216604 B.4 TLR43P1000 129177 H.34 U203X02K2SS 167426 H.9 U2KN30K0S 168011 H.16
SFE05 120043 B.4 TLR44P600 129166 H.12 U203X02K2SS 167426 H.12 U2KN37K0S 168052 H.16
SFE0K2 120047 B.4 TLR44P600 129166 H.34 U203X04K0FS 167407 H.9 U2KV23CNVKIT 168106 H.17
SFK0A 120001 B.2 TLR4P3000 129872 H.34 U203X04K0FS 167407 H.12 U2KV23DBUH1 168084 H.34
A SFK0B
SFK0C
120002
120003
B.2
B.2
TLR59P1000
TLR5P2500
129176
129871
H.34
H.34
U203X04K0SS
U203X04K0SS
167427
167427
H.9
H.12
U2KV23DBUH2
U2KV23DBUH3
168085
168086
H.34
H.34
SFK0D 120004 B.2 TLR7,4P1800 129172 H.34 U203X05K5FS 167408 H.9 U2KV23DBUH4 168083 H.34
SFK0E 120005 B.2 TLR74P200 129870 H.34 U203X05K5FS 167408 H.12 U2KV23DBUL1 168098 H.34
SFK0F 120006 B.2 TLR750P200 116301 H.4 U203X05K5SS 167428 H.9 U2KV23DBUL2 168099 H.34
B SFK0G
SFK0H
120007
120008
B.2
B.2
TLR750P200
TLR75P200
116301
116300
H.12
H.4
U203X05K5SS
U203X07K5FS
167428
167409
H.12
H.9
U2KV23DBUL3
U2KV23DN1
168100
168087
H.34
H.17
SFK0I 120009 B.2 TLR75P200 116300 H.12 U203X07K5FS 167409 H.12 U2KV23DN2 168088 H.17
SFK0J 120010 B.2 TLR8,8P1500 129171 H.34 U203X07K5SS 167429 H.9 U2KV23DN3 168089 H.17
SFK0K 120011 B.2 TLR864P200 129873 H.34 U203X07K5SS 167429 H.12 U2KV23PI0 168091 H.17
C SFK0L
SFK0M
120012
120013
B.2
B.2
TLR86P600
TLR86P600
129175
129175
H.12
H.34
U203X11K0FS
U203X11K0FS
167410
167410
H.9
H.12
U2KV23RY0
U2KV23RY1
168090
168050
H.17
H.17
SFM04 120044 B.4 U... U203X11K0SS 167430 H.9 U2KV23SL0 168092 H.17
SFM06 120045 B.4 U200ABK 167440 H.9 U203X11K0SS 167430 H.12 U2KV23SL6 168093 H.17
SFPE0 120053 B.4 U200ADN 167434 H.9 U20AF0K7 167085 H.4 U2KV23SL7 168048 H.17
D SFPS0
SFS04
120051
120040
B.4
B.4
U200ALCDK
U200ALEDK
167439
167438
H.9
H.9
U20AF2K2
U20AF2K2X
167086
167084
H.4
H.4
U2KV23SL8
U2KV23SL9
168047
168049
H.17
H.17
SFS04K1 245217 B.4 U200AMP 167437 H.9 U20AR0K7 167087 H.4 U2KV23W101 168103 H.17
SFS04M 212558 B.4 U200APB 167433 H.9 U20N0K2P 167088 H.3 U2KV23W103 168102 H.17
SFS05 120041 B.4 U200ARS232 167436 H.9 U20N0K2P 167088 H.7 U2KV23W113 168105 H.17
E SFS05M
SFS0K2
212559
120046
B.4
B.4
U200ARS485
U200AW05
167435
167441
H.9
H.9
U20N0K2PS
U20N0K2PS
167132
167132
H.3
H.7
U2KV23W123
U2KX00K4S
168104
168024
H.17
H.16
SFVB8 254537 B.5 U200AW10 167442 H.9 U20N0K2S 167075 H.3 U2KX00K7S 168025 H.16
SFVB8 254537 B.19 U200AW20 167443 H.9 U20N0K2S 167075 H.6 U2KX01K5S 168026 H.16
SFVCD 120054 B.4 U200AW30 167444 H.9 U20N0K4P 167089 H.3 U2KX02K2S 168027 H.16
F SFVH03
SFVN0
243713
101369
B.3
B.4
U200AW50
U200F611TA1
167445
167453
H.9
H.12
U20N0K4P
U20N0K4PS
167089
167133
H.7
H.3
U2KX04K0S
U2KX05K5S
168028
168029
H.16
H.16
SLSEP11 130411 G.25 U200F611TA1 167453 H.13 U20N0K4PS 167133 H.7 U2KX07K5S 168030 H.16
SLSER11 130410 G.25 U200F627TA2 167454 H.12 U20N0K4S 167076 H.3 U2KX110KS 168041 H.16
SLSHA11 130413 G.25 U200F627TA2 167454 H.12 U20N0K4S 167076 H.6 U2KX11K0S 168031 H.16
G SLSHG11
SLSI F BD22
130412
130400
G.25
G.22
U200F627TA2
U200F627TA2
167454
167454
H.12
H.13
U20N0K7P
U20N0K7P
167090
167090
H.3
H.7
U2KX132KS
U2KX15K0S
168042
168032
H.16
H.16
SLSI F UM22 130401 G.22 U200F709TA1 167456 H.12 U20N0K7PS 167134 H.3 U2KX160KS 168043 H.16
SLSI M BD22 L 130402 G.22 U200F709TA1 167456 H.13 U20N0K7PS 167134 H.7 U2KX18K5S 168033 H.16
SLSK0210 130409 G.23 U200F719TA2 167457 H.12 U20N0K7S 167077 H.3 U2KX200KS 168044 H.16
H SLSK11
SLSK2001
130407
130408
G.23
G.23
U200F719TA2
U200F739TA3
167457
167458
H.13
H.12
U20N0K7S
U20N1K5P
167077
167091
H.6
H.3
U2KX22K0S
U2KX250KS
168034
168045
H.16
H.16
SLSM11 130406 G.24 U200F739TA3 167458 H.13 U20N1K5P 167091 H.7 U2KX30K0S 168035 H.16
SLSP02 130404 G.24 U200F905TA1 167459 H.12 U20N1K5PS 167135 H.3 U2KX315KS 168046 H.16
SLSP0210 130405 G.24 U200F905TA1 167459 H.13 U20N1K5PS 167135 H.7 U2KX37K0S 168036 H.16
I SLSP11
SON-1
130403
123680
G.24
F.7
U200F910TA2
U200F910TA2
167460
167460
H.12
H.13
U20N1K5S
U20N1K5S
167078
167078
H.3
H.6
U2KX45K0S
U2KX55K0S
168037
168038
H.16
H.16
SON-2 123690 F.7 U200F928TA3 167461 H.12 U20N2K2P 167092 H.3 U2KX75K0S 168039 H.16
SON-3 123700 F.7 U200F928TA3 167461 H.13 U20N2K2P 167092 H.7 U2KX90K0S 168040 H.16
SPR 100549 A.20 U201N00K4FS 167400 H.9 U20N2K2PS 167136 H.3 V...
X SPR
SPR
100549
100549
A.24
C.8
U201N00K4FS
U201N00K4SS
167400
167411
H.12
H.9
U20N2K2PS
U20N2K2S
167136
167079
H.7
H.3
V1107BA
V1108B4
113612
113505
C.21
C.21
SPR 100549 C.17 U201N00K4SS 167411 H.12 U20N2K2S 167079 H.6 V1108CA 113614 C.21
SPR 100549 C.61 U201N00K7FS 167401 H.9 U20X0K7P 167093 H.3 V1109B4 113899 C.21
SYDW B611 213962 G.27 U201N00K7FS 167401 H.12 U20X0K7P 167093 H.7 V1109BA 113616 C.21
SYDW B611S 213964 G.27 U201N00K7SS 167412 H.9 U20X0K7PS 167137 H.3 V1110CE 113618 C.21
SYDW B711S 213965 G.27 U201N00K7SS 167412 H.12 U20X0K7PS 167137 H.7 V1111CE 113619 C.21
T... U201N01K5FS 167402 H.9 U20X0K7S 167080 H.3 V1112BA 113620 C.21
TLR100P200 108223 H.4 U201N01K5FS 167402 H.12 U20X0K7S 167080 H.6 V1113BA 113621 C.21
TLR100P200 108223 H.12 U201N01K5SS 167413 H.9 U20X1K5P 167094 H.3 V1175CA 113613 C.21

X.22
Control and Automation
Cat. no Ref. no. Page
V1185BA 113615 C.21
V1195BA 113617 C.21
V31200B 104738 C.17
V31201B 104739 C.17
V31202B 104741 C.17
V31203B 104743 C.17
V31204B 104745 C.17
V31205B 104747 C.17
V31206B 104749 C.17
V31207B 104750 C.17
V31208B 104752 C.17
V31209B 104754 C.17

By catalogue number
V31210B 104755 C.17
V31225B 104757 C.17
V31245B 104758 C.17
VB1201B 104740 C.17
VB1202B 104742 C.17
VB1203B 133170 C.17
VB1204B 133885 C.17
VB1205B 104748 C.17
VB1207B 104751 C.17
VB1208B 104753 C.17
W...
WKAT 105-1,2A/2V 204167 F.8
WKAT 105-10A/2V 204171 F.8
WKAT 140-1,2A/2V 204168 F.8
WKAT 140-10A/2V 204172 F.8
WKAT 210-1,2A/2V 123900 F.8
WKAT 210-1,2A/2V 123900 F.8
WKAT 210-10A/2V 204173 F.8
WKAT 35-1,2A/2V 204165 F.8
WKAT 35-10A/2V 204169 F.8
WKAT 70-1,2A/2V 204166 F.8
WKAT 70-1,2A/2V
WKAT 70-10A/2V
204166
204170
F.8
F.8
A
WKI0608 241752 D.21
WKI0910 241751 D.21
WKLE00 103238 D.23
WKLE02
WKLE25
103241
103243
D.23
D.23
B
WKLI02P 101422 D.3
WKLI02P 101422 D.21
WKLI04P 101424 D.3
WKLI04P
WKLI07P
101424
101426
D.21
D.3
C
WKLI07P 101426 D.21
WKLI25P 101423 D.3
WKLI25P 101423 D.21
WKLI45P
WKLI45P
101425
101425
D.3
D.21
D
WKMIU 101421 D.3
WKMIU 101421 D.21
WLSD 103247 D.23
WLSD1 241750 D.23 E

X.23
Control and Automation
Ref. no Cat. no Page Ref. no Cat. no Page Ref. no Cat. no Page Ref. no Cat. no Page
100000 100987 MARN404AT C.6 101242 GPS1BHAJ B.9 101330 GPAULRAAD B.18
100470 MB0ID A.17 100988 MARN413AT A.18 101243 GPS1BHAK B.9 101331 GPAULRAAC B.18
100470 MB0ID C.4 100988 MARN413AT C.6 101244 GPS1BHAL B.9 101332 GPAULRAAG B.18
100471 MB0KD A.17 100989 MARN422AT A.18 101245 GPS1BHAM B.9 101333 GPAULRAAF B.18
100471 MB0KD C.4 100989 MARN422AT C.6 101246 GPS1BHAN B.9 101334 GPAULRAAJ B.18
100503 MARF440AF A.18 100990 MARN431AT A.18 101247 GPS1BHAP B.9 101335 GPAULRAAM B.18
100503 MARF440AF C.6 100990 MARN431AT C.6 101248 GPS1BHAR B.9 101336 GPAULRAAN B.18
100504 MARF431AF A.18 100991 MARN440AT A.18 101249 GPS2BHAK B.11 101337 GPAULRAAR B.18
100504 MARF431AF C.6 100991 MARN440AT C.6 101250 GPS2BHAM B.11 101338 GPAULRAAU B.18
100505 MARF422AF A.18 100992 MARN202AT A.18 101251 GPS2BHAN B.11 101339 GPAULRAAW B.18
100505 MARF422AF C.6 100992 MARN202AT C.6 101252 GPS2BHAP B.11 101340 GPAULRAAY B.18
100506 MARF413AF A.18 100993 MARN211AT A.18 101253 GPS2BHAR B.11 101341 GPAU20LTAAD B.18
100506 MARF413AF C.6 100993 MARN211AT C.6 101254 GPS2BHAS B.11 101342 GPAU20LTAAC B.18
By reference number

100507 MARF404AF A.18 100994 MARN220AT A.18 101255 GPS2BHAT B.11 101343 GPAU20LTAAG B.18
100507 MARF404AF C.6 100994 MARN220AT C.6 101256 GPS2BHAU B.11 101344 GPAU20LTAAF B.18
100513 MARL110AT A.19 100995 MACN413AT C.6 101257 GPS1MSAA B.13 101345 GPAU20LTAAJ B.18
100514 MARL101AT A.19 100996 MACN422AT C.6 101258 GPS1MSAB B.13 101346 GPAU20LTAAM B.18
100515 MARL110AF A.19 100997 MACN431AT C.6 101259 GPS1MSAC B.13 101347 GPAU20LTAAN B.18
100516 MARL101AF A.19 100998 MACN202AT C.6 101260 GPS1MSAD B.13 101348 GPAU20LTAAR B.18
100517 MARL110AI A.19 100999 MACN211AT C.6 101261 GPS1MSAE B.13 101349 GPAU20LTAAU B.18
100518 MARL101AI A.19 101000 MT03A C.61 101262 GPS1MSAF B.13 101350 GPAU20LTAAW B.18
100519 MARL110ATS A.19 101001 MT03B C.61 101263 GPS1MSAG B.13 101351 GPAU20LTAAY B.18
100519 MARL110ATS C.7 101002 MT03C C.61 101264 GPS1MSAH B.13 101352 GPAU20LCAAD B.18
100520 MARL101ATS A.19 101003 MT03D C.61 101265 GPS1MSAJ B.13 101353 GPAU20LCAAC B.18
100520 MARL101ATS C.7 101004 MT03E C.61 101266 GPS1MSAK B.13 101354 GPAU20LCAAG B.18
100521 MARL110AFS A.19 101005 MT03F C.61 101267 GPS1MSAL B.13 101355 GPAU20LCAAF B.18
100521 MARL110AFS C.7 101006 MT03G C.61 101268 GPS1MSAM B.13 101356 GPAU20LCAAJ B.18
100522 MARL101AFS A.19 101007 MT03H C.61 101269 GPS1MSAN B.13 101357 GPAU20LCAAM B.18
100522 MARL101AFS C.7 101008 MT03I C.61 101270 GPS1MSAP B.13 101358 GPAU20LCAAN B.18
100523 MARL110AIS A.19 101009 MT03J C.61 101271 GPS1MSAR B.13 101359 GPAU20LCAAR B.18
100523 MARL110AIS C.7 101010 MT03K C.61 101272 GPS2MSAK B.15 101360 GPAU20LCAAU B.18
100524 MARL101AIS A.19 101011 MT03L C.61 101273 GPS2MSAM B.15 101361 GPAU20LCAAW B.18
100524 MARL101AIS C.7 101012 MT03M C.61 101274 GPS2MSAN B.15 101362 GPAU20LCAAY B.18
A 100530
100531
MCRI040ATD
MCRI031ATD
A.17
A.17
101013
101014
MT03N
MT03P
C.61
C.61
101275
101276
GPS2MSAP
GPS2MSAR
B.15
B.15
101363
101364
GPA1HAB
GPA1HAR
B.19
B.19
100532 MCRI022ATD A.17 101015 MT03R C.61 101277 GPS2MSAS B.15 101365 GPES41A B.21
100533 MCRK040ATD A.17 101017 SBELA C.15 101278 GPS2MSAT B.15 101366 GPES55A B.21
100534 MCRK031ATD A.17 101020 MVE0T C.61 101279 GPS2MSAU B.15 101367 GPEF41A B.21
B 100535
100536
MCRK022ATD
MP0DAE4
A.17
A.20
101021
101022
MVB0T
MATV10AT
C.61
C.61
101280
101281
GPS1MHAA
GPS1MHAB
B.13
B.13
101368
101369
GPEF55A
SFVN0
B.21
B.4
100536 MP0DAE4 C.8 101095 LG2506P1B0 D.19 101282 GPS1MHAC B.13 101369 GPENA B.21
100538 MC2I301ATD C.4 101194 GPASLRAA11 B.18 101283 GPS1MHAD B.13 101370 GPEPA B.21
100541 MREBC10AC2 A.20 101195 GPS1BSAAMP B.9 101284 GPS1MHAE B.13 101371 GPECA B.21
C 100541
100542
MREBC10AC2
MREBC20AC2
C.8
A.20
101196
101197
GPS1BSABMP
GPS1BSACMP
B.9
B.9
101285
101286
GPS1MHAF
GPS1MHAG
B.13
B.13
101372
101373
GPEPMA
GPEPLA
B.21
B.21
100542 MREBC20AC2 C.8 101198 GPS1BSADMP B.9 101287 GPS1MHAH B.13 101374 GPEPKA B.21
100543 MVB0R A.20 101199 GPS1BSAEMP B.9 101288 GPS1MHAJ B.13 101375 GPELGAJ B.4
100543 MVB0R C.8 101200 GPS1BSAFMP B.9 101289 GPS1MHAK B.13 101375 GPELGAJ B.21
D 100544
100544
MP0AAE1
MP0AAE1
A.20
C.8
101201
101202
GPS1BSAGMP
GPS1BSAHMP
B.9
B.9
101290
101291
GPS1MHAL
GPS1MHAM
B.13
B.13
101376
101376
GPELGAN
GPELGAN
B.4
B.21
100545 MP0AAE2 A.20 101203 GPS1BSAJMP B.9 101292 GPS1MHAN B.13 101377 GPELGAU B.4
100545 MP0AAE2 C.8 101204 GPS1BSAKMP B.9 101293 GPS1MHAP B.13 101377 GPELGAU B.21
100546 MP0CAE3 A.20 101205 GPS1BSALMP B.9 101294 GPS1MHAR B.13 101378 GPELGAX B.4
E 100546
100547
MP0CAE3
MMH0
C.8
A.20
101206
101207
GPS1BSAMMP
GPS1BSANMP
B.9
B.9
101295
101296
GPS2MHAK
GPS2MHAM
B.15
B.15
101378
101379
GPELGAX
GPELGAY
B.21
B.4
100547 MMH0 C.8 101208 GPS1BSAPMP B.9 101297 GPS2MHAN B.15 101379 GPELGAY B.21
100548 EAT 260 A.20 101209 GPS1BSARMP B.9 101298 GPS2MHAP B.15 101380 GPELRAJ B.4
100548 EAT 260 A.24 101211 GPS1BSAA B.9 101299 GPS2MHAR B.15 101380 GPELRAJ B.21
F 100548
100548
EAT 260
EAT 260
C.8
C.17
101212
101213
GPS1BSAB
GPS1BSAC
B.9
B.9
101300
101301
GPS2MHAS
GPS2MHAT
B.15
B.15
101381
101381
GPELRAN
GPELRAN
B.4
B.21
100548 EAT 260 C.61 101214 GPS1BSAD B.9 101302 GPS2MHAU B.15 101382 GPELRAU B.4
100549 SPR A.20 101215 GPS1BSAE B.9 101303 GPAC10FBA B.17 101382 GPELRAU B.21
100549 SPR A.24 101216 GPS1BSAF B.9 101304 GPAC01FBA B.17 101383 GPELRAX B.4
G 100549
100549
SPR
SPR
C.8
C.17
101217
101218
GPS1BSAG
GPS1BSAH
B.9
B.9
101305
101306
GPAC11LLA
GPAC20LLA
B.17
B.17
101383
101384
GPELRAX
GPELRAY
B.21
B.4
100549 SPR C.61 101219 GPS1BSAJ B.9 101307 GPAC02LLA B.17 101384 GPELRAY B.21
100555 MACF431AF C.6 101220 GPS1BSAK B.9 101308 GPAC11LRA B.17 101385 GPELCAJ B.4
100556 MACF422AF C.6 101221 GPS1BSAL B.9 101309 GPAC20LRA B.17 101385 GPELCAJ B.21
H 100557
100559
MACF413AF
MC2I310ATD
C.6
C.4
101222
101223
GPS1BSAM
GPS1BSAN
B.9
B.9
101310
101311
GPAC02LRA
GPAL10FRA
B.17
B.17
101386
101386
GPELCAN
GPELCAN
B.4
B.21
100560 MACL110AT C.7 101224 GPS1BSAP B.9 101312 GPAL01FRA B.17 101387 GPELCAU B.4
100561 MACL101AT C.7 101225 GPS1BSAR B.9 101313 GPAD1010LLA B.17 101387 GPELCAU B.21
100562 MACL110AF C.7 101226 GPS2BSAK B.11 101314 GPAD1001LLA B.17 101388 GPELCAX B.4
I 100563
100564
MACL101AF
MACL110AI
C.7
C.7
101227
101228
GPS2BSAM
GPS2BSAN
B.11
B.11
101315
101316
GPAD0110LLA
GPAD0101LLA
B.17
B.17
101388
101389
GPELCAX
GPELCAY
B.21
B.4
100565 MACL101AI C.7 101229 GPS2BSAP B.11 101317 GPAE11LLA B.17 101389 GPELCAY B.21
100570 MC0I310ATD C.4 101230 GPS2BSAR B.11 101318 GPASLRAA1 B.18 101390 GPB1B02A B.19
100571 MC0I301ATD C.4 101231 GPS2BSAS B.11 101319 GPASLRAAF B.18 101391 GPB1B03A B.19
X 100572
100573
MC1I310ATD
MC1I301ATD
C.4
C.4
101232
101233
GPS2BSAT
GPS2BSAU
B.11
B.11
101320
101321
GPASLRAAG
GPASLRAAJ
B.18
B.18
101392
101392
GPB104A
GPB1B04A
B.5
B.19
100574 MC0K310ATD C.4 101234 GPS1BHAA B.9 101322 GPASLRAAM B.18 101393 GPB105A B.5
100575 MC0K301ATD C.4 101235 GPS1BHAB B.9 101323 GPASLRAAN B.18 101393 GPB1B05A B.19
100576 MC1K310ATD C.4 101236 GPS1BHAC B.9 101324 GPASLRAAR B.18 101394 GPB1B12A B.19
100577 MC1K301ATD C.4 101237 GPS1BHAD B.9 101325 GPASLRAAU B.18 101395 GPB1B13A B.19
100600 MVP0C C.8 101238 GPS1BHAE B.9 101326 GPASLRAAW B.18 101396 GPB1B14A B.19
100608 MAGL110AT D.19 101239 GPS1BHAF B.9 101327 GPASLRAAY B.18 101397 GPB1B15A B.19
100885 LG2504P1B0 D.19 101240 GPS1BHAG B.9 101328 GPASLRADD B.18 101398 GPB1B22A B.19
100987 MARN404AT A.18 101241 GPS1BHAH B.9 101329 GPASLRADJ B.18 101399 GPB1B24A B.19

X.24
Control and Automation
Ref. no Cat. no Page Ref. no Cat. no Page Ref. no Cat. no Page Ref. no Cat. no Page
101400 GPB2B02A B.19 103558 MACN202AR C.6 104760 KRC24 C.21 108906 BTRF60D A.23
101401 GPB2B03A B.19 103559 MACN431AR C.6 104761 KRC48/260 C.21 108906 BTRF60D C.15
101402 GPB2B04A B.19 103560 MACN422AR C.6 104762 KRC380/415 C.21 110000
101403 GPB2B12A B.19 103561 MACN413AR C.6 104763 BEKH C.21 110360 GPAU20LTAA11 B.18
101404 GPB2B13A B.19 103562 MVE0R C.61 104764 BEKV C.21 110565 RT3PXX3P C.65
101405 GPB2B14A B.19 103563 MATV10AR C.61 104766 C09476 C.21 110836 BSLV3U A.24
101406 GPB2B22A B.19 103590 MC2K310ATD C.4 104767 KVP12G D.19 110836 BSLV3U C.16
101407 GPB2B24A B.19 103591 MC2K301ATD C.4 104770 KVP85G D.19 110836 BSLV3U C.21
101408 GPB1GA B.5 103747 PTPCK75 C.21 104771 KVP10G D.19 112185 GPAU20LCAA11 B.18
101408 GPB1GA B.19 103747 PTPCK75 C.65 104785 BEKVA 1 C.21 113001 BTLFX A.23
101409 GPB2GA B.19 103748 PTPCK95 C.21 104786 BEKVS 1 C.21 113001 BTLFX C.15
101410 GPF1LMCBA D.3 103749 PTPCK11 C.21 104797 BNL D.19 113505 V1108B4 C.21

By reference number
101411 GPF1L02AA D.3 104587 KVB12E D.23 104798 EPL D.19 113592 IMV3R A.25
101412 GPF1L02DA D.3 104597 KVB10E D.23 104800 BMLF D.19 113592 IMV3R C.16
101413 GPF1L25AA D.3 104690 KVB75I D.21 105170 RTXP C.65 113593 IMV3K A.25
101414 GPF1L25DA D.3 104691 KVB95I D.21 105200 CM1CA5F C.21 113593 IMV3K C.16
101415 GPF2L45AA D.3 104692 KVB10I D.21 106622 BRLL02 C.15 113594 IMV3G A.25
101416 GPF2L45DA D.3 104693 KVB12I D.21 106622 BRLL02 C.20 113594 IMV3G C.16
101417 GPF2L07AA D.3 104694 KVB75E D.23 107097 GPEUTA B.21 113595 IMD1Z A.25
101418 GPF1B1A D.3 104695 KVB95E D.23 107098 GPF00C02 D.3 113595 IMD1Z C.16
101419 GPF2B2A D.3 104700 BCLF10 A.23 107099 GPF10C02 D.3 113596 IMRC3R C.16
101420 GPF2B3A D.3 104700 BCLF10 C.15 107100 GPF01C02 D.3 113597 IMRC3K C.16
101421 WKMIU D.3 104701 BCLF01 A.23 107101 GPF00C25 D.3 113598 IMRC3G C.16
101421 WKMIU D.21 104701 BCLF01 C.15 107102 GPF00C04 D.3 113599 IMRC2R A.25
101422 WKLI02P D.3 104702 BCLF10G A.23 107103 GPF10C04 D.3 113599 IMRC2R C.16
101422 WKLI02P D.21 104702 BCLF10G C.15 107105 GPF01C04 D.3 113600 IMRC2K A.25
101423 WKLI25P D.3 104703 BCLF01G A.23 107106 GPF00C45 D.3 113600 IMRC2K C.16
101423 WKLI25P D.21 104703 BCLF01G C.15 107107 GPF00C08 D.3 113601 IMRC2G A.25
101424 WKLI04P D.3 104704 BRLL20 A.23 107119 GPS2BSAL B.11 113601 IMRC2G C.16
101424 WKLI04P D.21 104704 BRLL20 C.15 107120 GPS2BHAL B.11 113602 BETL02C A.25
101425 WKLI45P D.3 104704 BRLL20 C.20 107121 GPS2MSAL B.15 113602 BETL02C C.16
101425 WKLI45P D.21 104705 BRLL11 A.23 107122 GPS2MHAL B.15 113603 BETL45C A.25
101426 WKLI07P D.3 104705 BRLL11 C.15 107138 PBF13ECBA D.4 113603 BETL45C C.16
101426
101427
WKLI07P
GPF1CBA
D.21
D.3
104705
104706
BRLL11
BCLL20
C.20
C.15
107139
107140
PBF13FCBA
PBF13FDBA
D.4
D.4
113604
113604
BETL02D
BETL02D
A.25
C.16
A
101502 GPA2HAB B.19 104706 BCLL20 C.20 107142 PBF23ECBA D.4 113605 BETL45D A.25
101503 GPA2HAR B.19 104707 BCLL11 C.15 107143 PBF23FCBA D.4 113605 BETL45D C.16
101509 GPAKS1A B.18 104707 BCLL11 C.20 107145 PBF23FDBA D.4 113606 IMRD A.25
101511
101512
GPB1GAF
GPF1L25CT1
B.19
D.3
104709
104709
BTLF30C
BTLF30C
A.23
C.15
107146
107147
PBF13EBCA
PBF13EBDA
D.4
D.4
113606
113607
IMRD
IMRG
C.16
A.25
B
101513 GPF1L45CT1 D.3 104710 BTLF60C A.23 107148 PBF13ECDA D.4 113607 IMRG C.16
101514 GPVDA B.18 104710 BTLF60C C.15 107149 PBF13FDEA D.4 113608 IMRFD A.25
101515 GPVPA B.18 104711 BTLF30D A.23 107150 PBF13GDFA D.4 113608 IMRFD C.16
102625
103238
GPAULRAA11
WKLE00
B.18
D.23
104711
104712
BTLF30D
BTLF60D
C.15
A.23
107151
107152
PBF23EBCA
PBF23EBDA
D.4
D.4
113609
113609
IMRFG
IMRFG
A.25
C.16
C
103241 WKLE02 D.23 104712 BTLF60D C.15 107153 PBF23ECDA D.4 113610 IMSSD A.25
103243 WKLE25 D.23 104713 BSLR2G A.24 107155 PBF23FDEA D.4 113610 IMSSD C.16
103247 WLSD D.23 104713 BSLR2G C.16 107156 PBF23GDFA D.4 113611 IMAMS A.25
103298
103298
MARL101ARS
MARL101ARS
A.19
C.7
104714
104714
BSLR2K
BSLR2K
A.24
C.16
107157
107158
PBF2AEAHA
PBF2AFAHA
D.4
D.4
113611
113612
IMAMS
V1107BA
C.16
C.21
D
103299 MARL110ARS A.19 104715 BSLR2R A.24 107159 PBF2AGAHA D.4 113613 V1175CA C.21
103299 MARL110ARS C.7 104715 BSLR2R C.16 107160 PBFAABALA D.4 113614 V1108CA C.21
103300 MARN404AR A.18 104716 BSLR3G C.16 107161 PBFAAAAMA D.4 113615 V1185BA C.21
103300
103349
MARN404AR
MARN220AR
C.6
A.18
104716
104717
BSLR3G
BSLR3K
C.21
C.16
107162
107163
PBFAAAANA
GPF1B4A
D.4
D.3
113616
113617
V1109BA
V1195BA
C.21
C.21
E
103349 MARN220AR C.6 104717 BSLR3K C.21 107165 GPF1L04AA D.3 113618 V1110CE C.21
103350 MARN211AR A.18 104718 BSLR3R C.16 107166 GPF1L04DA D.3 113619 V1111CE C.21
103350 MARN211AR C.6 104718 BSLR3R C.21 107182 GPAPTP2A B.18 113620 V1112BA C.21
103351
103351
MARN202AR
MARN202AR
A.18
C.6
104719
104719
BSLDZ
BSLDZ
A.24
C.16
107186
107187
GPB1FA
GPB2FA
B.19
B.19
113621
113627
V1113BA
KVP75U
C.21
D.21
F
103352 MARN440AR A.18 104720 BSLV3G A.24 107190 GPF2L04AA D.3 113628 KVP85U D.21
103352 MARN440AR C.6 104720 BSLV3G C.16 107191 GPF2L04DA D.3 113630 KVP12U D.21
103353 MARN431AR A.18 104721 BSLV3K A.24 107252 GPF3L09AA D.3 113631 KVP85I D.21
103353
103354
MARN431AR
MARN422AR
C.6
A.18
104721
104722
BSLV3K
BSLV3R
C.16
A.24
107253
107256
GPF3B5A
SFB0RJM
D.3
B.3
113633
113637
KVP12I
KVP95E
D.21
D.23
G
103354 MARN422AR C.6 104722 BSLV3R C.16 107315 GPAPT1E B.19 113640 RT12K C.63
103355 MARN413AR A.18 104723 BELA A.24 107380 PBF1AAAPA D.4 113641 RT12L C.63
103355 MARN413AR C.6 104723 BELA C.15 107381 PBF2AAAQA D.4 113642 RT12M C.63
103540
103541
MT03RA
MT03RB
C.61
C.61
104724
104724
BELA02
BELA02
A.24
C.15
107382
107383
PBFCAFAN-A
PBF2AAARA
D.4
D.4
113643
113644
RT12N
RT12P
C.63
C.63
H
103542 MT03RC C.61 104738 V31200B C.17 108223 TLR100P200 H.4 113645 RT12S C.63
103543 MT03RD C.61 104739 V31201B C.17 108223 TLR100P200 H.12 113646 RT12T C.63
103544 MT03RE C.61 104740 VB1201B C.17 108223 TLR100P200 H.12 113647 RT12U C.63
103545
103546
MT03RF
MT03RG
C.61
C.61
104741
104742
V31202B
VB1202B
C.17
C.17
108223
108227
TLR100P200
TLR250P200
H.12
H.4
113648
113649
RT12V
RT12W
C.63
C.63
I
103547 MT03RH C.61 104743 V31203B C.17 108227 TLR240P200 H.12 113650 RT22D C.63
103548 MT03RI C.61 104745 V31204B C.17 108227 TLR240P200 H.12 113651 RT22E C.63
103549 MT03RJ C.61 104747 V31205B C.17 108864 RTXBS C.65 113652 RT22G C.63
103550
103551
MT03RK
MT03RL
C.61
C.61
104748
104749
VB1205B
V31206B
C.17
C.17
108901
108901
BCRF10
BCRF10
A.23
C.15
113653
113654
RT22H
RT22J
C.63
C.63
X
103552 MT03RM C.61 104750 V31207B C.17 108902 BCRF01 A.23 113655 RT22L C.63
103553 MT03RN C.61 104751 VB1207B C.17 108902 BCRF01 C.15 113656 RT22M C.63
103554 MT03RP C.61 104752 V31208B C.17 108903 BTRF30C A.23 113657 RT32C C.64
103555 MACL110AR C.7 104753 VB1208B C.17 108903 BTRF30C C.15 113658 RT32D C.64
103556 MARL110AR A.19 104754 V31209B C.17 108904 BTRF60C A.23 113659 RT32E C.64
103556 MACL101AR C.7 104755 V31210B C.17 108904 BTRF60C C.15 113660 RT32F C.64
103557 MARL101AR A.19 104757 V31225B C.17 108905 BTRF30D A.23 113700 RT1B C.63
103557 MACN211AR C.6 104758 V31245B C.17 108905 BTRF30D C.15 113701 RT1C C.63

X.25
Control and Automation
Ref. no Cat. no Page Ref. no Cat. no Page Ref. no Cat. no Page Ref. no Cat. no Page
113702 RT1D C.63 114102 RT1RV C.63 120115 SFB0RUM B.3 129155 ERX01K5 H.13
113703 RT1F C.63 114103 RT1RW C.63 120460 QS1BNA D.73 129156 ERX02K2 H.12
113704 RT1G C.63 114104 RT2RA C.63 120461 QS2BNA D.73 129156 ERX02K2 H.13
113705 RT1H C.63 114105 RT2RB C.63 120462 QS1DNA D.73 129157 ERX04K0 H.12
113706 RT1J C.63 114106 RT2RC C.63 120463 QS2DNA D.73 129157 ERX04K0 H.13
113707 RT1K C.63 114107 RT2RD C.63 120464 QS1FNA D.73 129158 ERX05K5 H.12
113708 RT1L C.63 114108 RT2RE C.63 120465 QS2FNA D.73 129158 ERX05K5 H.13
113709 RT1M C.63 114109 RT2RG C.63 120466 QS1GNA D.73 129159 ERX07K5 H.12
113710 RT1N C.63 114110 RT2RH C.63 120467 QS2GNA D.73 129159 ERX07K5 H.13
113711 RT1P C.63 114111 RT2RJ C.63 120468 QS1HNA D.73 129165 TLR200P200 H.12
113712 RT1S C.63 114112 RT2RL C.63 120469 QS2HNA D.73 129166 TLR44P600 H.12
113713 RT1T C.63 114113 RT2RM C.63 120470 QS1INA D.73 129166 TLR44P600 H.34
113714 RT1U C.63 114114 RT12RK C.63 120471 QS2INA D.73 129167 TLR29P600 H.12
By reference number

113715 RT1V C.63 114115 RT12RL C.63 120881 QA02P008S D.67 129167 TLR29P600 H.34
113716 RT1W C.63 114116 RT12RM C.63 120882 QA02P017S D.67 129168 TLR22P600 H.12
113717 RT2A C.63 114117 RT12RN C.63 120883 QA02P022S D.67 129168 TLR22P600 H.34
113718 RT2B C.63 114118 RT12RP C.63 120884 QA02P031S D.67 129169 TLR15P1000 H.34
113719 RT2C C.63 114119 RT12RS C.63 120885 QA02P044S D.67 129170 TLR11P1200 H.34
113720 RT2D C.63 114120 RT12RT C.63 120886 QA02P058S D.67 129171 TLR8,8P1500 H.34
113721 RT2E C.63 114121 RT12RU C.63 120892 QA12P008S D.67 129172 TLR7,4P1800 H.34
113722 RT2G C.63 114122 RT12RV C.63 120893 QA12P017S D.67 129173 TLR175P600 H.12
113723 RT2H C.63 114123 RT12RW C.63 120894 QA12P022S D.67 129173 TLR175P600 H.34
113724 RT2J C.63 114124 RT22RD C.63 120895 QA12P031S D.67 129174 TLR118P600 H.12
113725 RT2L C.63 114125 RT22RE C.63 120896 QA12P044S D.67 129174 TLR118P600 H.34
113726 RT2M C.63 114126 RT22RG C.63 120897 QA12P058S D.67 129175 TLR86P600 H.12
113727 RT3B C.64 114127 RT22RH C.63 120898 QA22P008S D.67 129175 TLR86P600 H.34
113728 RT3C C.64 114128 RT22RJ C.63 120899 QA22P017S D.67 129176 TLR59P1000 H.34
113729 RT3D C.64 114129 RT22RL C.63 120900 QA22P022S D.67 129177 TLR43P1000 H.12
113730 RT3E C.64 114130 RT22RM C.63 120901 QA22P031S D.67 129177 TLR43P1000 H.34
113731 RT3F C.64 114159 RT12RJ C.63 120902 QA22P044S D.67 129700 ACR90A0H22 H.35
113732 RT4N C.64 116011 LG0006S1B0 D.19 120903 QA22P058S D.67 129701 ACR115A0H18 H.35
113733 RT4P C.64 116074 MG0006QAT0 D.19 120904 QA32P008S D.67 129702 ACR160A0H14 H.35
113734 RT4R C.64 116212 KVP08E D.23 120905 QA32P017S D.67 129703 ACR185A0H11 H.35
A 113735
113736
RT4LA
RT4LB
C.64
C.64
116226
116235
LG2504R1B0
KVP12E
D.19
D.23
120906
120907
QA32P022S
QA32P031S
D.67
D.67
129704
129705
ACR225A0H096
ACR300A0H067
H.35
H.35
113737 RT4LC C.64 116300 TLR75P200 H.4 120908 QA32P044S D.67 129706 ACR360A0H056 H.35
113738 RT4LD C.64 116300 TLR75P200 H.12 120909 QA32P058S D.67 129707 ACR460A0H056 H.35
113739 RT4LE C.64 116301 TLR750P200 H.4 120910 QAOPTDIN D.67 129708 ACR550A0H039 H.35
B 113740
113741
RT4LF
RT4LG
C.64
C.64
116301
116302
TLR750P200
TLR400P200
H.12
H.4
122004
122034
MTCAN
METAN
F.3
F.3
129709
129728
ACR625A0H035
QC1FDP
H.35
D.80
113742 RT4LH C.64 116302 TLR400P200 H.12 122045 MET t AN F.3 129729 QC2FDP D.80
113743 RT4LJ C.64 116402 MG0006RAT0 D.19 122054 MRD-5AN F.3 129730 QC1GDP D.80
113744 RT4LK C.64 116651 LG0004R1B0 D.19 122064 MRD-10AN F.3 129731 QC2GDP D.80
C 113745
113746
RT4LL
RT4LM
C.64
C.64
116652
116653
LG0006R1B0
LG0404P1B0
D.19
D.19
122074
122084
MRD-50AN
MRD-100AN
F.3
F.3
129732
129733
QC1HDP
QC2HDP
D.80
D.80
113747 RT4LN C.64 116656 LG0406P1B0 D.19 122094 MRD-700AN F.3 129734 QC1IDP D.80
113748 RT4LP C.64 116996 LG0404S1B0 D.19 122534 RET 50ENU F.6 129735 QC2IDP D.80
113749 RT4LR C.64 116997 LG0406S1B0 D.19 123603 RCR 1AJ F.6 129736 QC1JDP D.80
D 113750
113751
RT5A
RT5B
C.64
C.64
120000
120001 SFK0A B.2
123604
123656
RCR 1EN
DINIL 02E ENU
F.6
F.7
129737
129738
QC2JDP
QC1KDP
D.80
D.80
113752 RT5C C.64 120002 SFK0B B.2 123666 DINIL 03E ENU F.7 129739 QC2KDP D.80
113753 RT5D C.64 120003 SFK0C B.2 123680 SON-1 F.7 129740 QC1LDP D.80
113754 RT5E C.64 120004 SFK0D B.2 123690 SON-2 F.7 129741 QC2LDP D.80
E 113755
113756
RT5LA
RT5LB
C.64
C.64
120005
120006
SFK0E
SFK0F
B.2
B.2
123700
123900
SON-3
WKAT 210-1,2A/2V
F.7
F.8
129742
129743
QC1MDP
QC2MDP
D.80
D.80
113757 RT5LC C.64 120007 SFK0G B.2 123900 WKAT 210-1,2A/2V F.8 129744 QC1NDP D.80
113758 RT5LD C.64 120008 SFK0H B.2 124044 RDMT1-50AN F.9 129745 QC2NDP D.80
113759 RT5LE C.64 120009 SFK0I B.2 124045 RDMT1-50AU F.9 129746 QC1QDP D.80
F 113760
113761
RT6A
RT6LA
C.64
C.64
120010
120011
SFK0J
SFK0K
B.2
B.2
124900
124901
NMTCV
NMTCV 2
F.4
F.4
129746
129747
QC1QDP
QC2QDP
D.80
D.80
113762 RTX3 C.65 120012 SFK0L B.2 124905 NMTCIV F.4 129748 QC1RDP D.80
113764 RT2XP C.65 120013 SFK0M B.2 124906 NMTCSV F.4 129749 QC2RDP D.80
113850 PTP04 C.17 120020 SFAL11N B.3 124907 NMICV F.4 129750 QC1SDP D.80
G 113851
113852
PTP45
PTP08
C.17
C.17
120021
120022
SFAL20N
SFAL11D
B.3
B.3
124908
124912
NMETV
NMRDV-6
F.4
F.5
129751
129752
QC2SDP
QC1TDP
D.80
D.80
113853 PTP10 C.17 120023 SFAL20D B.3 124913 NMRDV-60 F.5 129753 QC2TDP D.80
113855 RTXS C.65 120024 SFAI11 B.3 124914 NMRDV-600 F.5 129754 QC1UDP D.80
113856 RTXSL C.65 120025 SFAK10 B.3 124915 NMRDV 2-6 F.5 129755 QC2UDP D.80
H 113899
114060
V1109B4
RT12RD
C.21
C.63
120026
120027
SFAK01
SFAL11S
B.3
B.3
124916
124917
NMRDV 2-60
NMRDV 2-600
F.5
F.5
129756
129757
QC1VDP
QC2VDP
D.80
D.80
114061 RT12RF C.63 120030 SFB0AJ B.3 124927 NMTDV F.5 129758 QC1XDP D.80
114062 RT12RG C.63 120031 SFB0AN B.3 124928 NMIFV F.5 129759 QC2XDP D.80
114063 RT12RH C.63 120032 SFB0AU B.3 124929 NMIVV F.5 129768 QCPDNT D.80
I 114087
114088
RT1RB
RT1RC
C.63
C.63
120034
120035
SFB0RJ
SFB0RN
B.3
B.3
124930
129148
NMMFV
ERN00K7
F.5
H.12
129769
129788
QCPPDP
ACR3A7H0
D.80
H.4
114089 RT1RD C.63 120036 SFB0RU B.3 129148 ERN00K7 H.13 129791 ACR8A2H5 H.4
114090 RT1RF C.63 120040 SFS04 B.4 129149 ERN01K5 H.12 129791 ACR8A2H5 H.12
114091 RT1RG C.63 120041 SFS05 B.4 129149 ERN01K5 H.13 129791 ACR8A2H5 H.12
X 114092
114093
RT1RH
RT1RJ
C.63
C.63
120042
120043
SFE04
SFE05
B.4
B.4
129150
129150
ERN02K2
ERN02K2
H.12
H.13
129792
129792
ACR12A2H5
ACR12A2H5
H.4
H.12
114094 RT1RK C.63 120044 SFM04 B.4 129151 ERN04K0 H.12 129793 ACR18A1H3 H.4
114095 RT1RL C.63 120045 SFM06 B.4 129151 ERN04K0 H.13 129793 ACR18A1H3 H.12
114096 RT1RM C.63 120046 SFS0K2 B.4 129152 ERN05K5 H.12 129794 ACR22A0H84 H.4
114097 RT1RN C.63 120047 SFE0K2 B.4 129152 ERN05K5 H.13 129794 ACR22A0H84 H.12
114098 RT1RP C.63 120051 SFPS0 B.4 129153 ERN07K5 H.12 129867 TLR405P200 H.34
114099 RT1RS C.63 120053 SFPE0 B.4 129153 ERN07K5 H.13 129868 TLR216P200 H.34
114100 RT1RT C.63 120054 SFVCD B.4 129154 ERX00K7 H.12 129869 TLR108P200 H.34
114101 RT1RU C.63 120114 SFB0RNM B.3 129155 ERX01K5 H.12 129870 TLR74P200 H.34

X.26
Control and Automation
Ref. no Cat. no Page Ref. no Cat. no Page Ref. no Cat. no Page Ref. no Cat. no Page
129871 TLR5P2500 H.34 130032 ISGV-B411 G.3 132000 101PMN1 E.83 132531 115PD15210T G.18
129872 TLR4P3000 H.34 130033 IMGV-B411 G.3 132001 101PMR1 E.83 132532 115PD38350T G.18
129873 TLR864P200 H.34 130034 ISGP-B311 G.3 132002 101PMV1 E.83 132533 115PD2970T G.18
129875 TLR432P200 H.34 130035 IMGP-B311 G.3 132003 101PMG1 E.83 132534 115PD215210T G.18
129876 TLR295P200 H.34 130036 ISGC-B411 G.3 132010 101PMN11 E.83 132535 115PD238350T G.18
129877 TLR35P1500 H.34 130037 IMGC-B411 G.3 132011 101PMR11 E.83 132540 115PD970L G.18
129878 TLR29P1800 H.34 130038 ISGQ-B311 G.3 132012 101PMV11 E.83 132541 115PD15210L G.18
129879 TLR22P2500 H.34 130039 IMGQ-B311 G.3 132013 101PMG11 E.83 132542 115PD38350L G.18
129880 TLR18P3000 H.34 130040 ISGM-B311 G.3 132020 101PMN22 E.83 132543 115PD2970L G.18
129881 TLR15P3700 H.34 130041 IMGM-B311 G.3 132021 101PMR22 E.83 132544 115PD215210L G.18
129925 ACR140A0H072 H.35 130042 IMGF-B411 G.3 132022 101PMV22 E.83 132545 115PD238350L G.18
129926 ACR180A0H056 H.35 130043 IMGG-B411 G.3 132023 101PMG22 E.83 132550 115PD970LT G.18

By reference number
129927 ACR200A0H051 H.35 130060 IUGA-B211 G.5 132099 101 TNC E.83 132551 115PD15210LT G.18
129928 ACR70A0H29 H.35 130061 IUCA-B211 G.5 132150 101FPMN1 E.83 132552 115PD38350LT G.18
129978 ACR4A2H5 H.12 130062 IUGU-B211 G.5 132151 101FPMR1 E.83 132553 115PD2970LT G.18
129978 ACR4A2H5 H.35 130063 IUCU-B211 G.5 132152 101FPMV1 E.83 132554 115PD215210LT G.18
129979 ACR6A2H5 H.4 130064 IUGR-B211 G.5 132153 101FPMG1 E.83 132555 115PD238350LT G.18
129979 ACR6A2H5 H.12 130065 IUCR-B211 G.5 132160 101FPMN2 E.83 132562 115807SP G.19
129979 ACR6A2H5 H.35 130066 IUGH-B211 G.5 132161 101FPMR2 E.83 132563 115803SP G.19
129980 ACR9A1H3 H.4 130067 IUCH-B211 G.5 132162 101FPMV2 E.83 132564 115805SP G.19
129980 ACR9A1H3 H.12 130068 IUGI-B211 G.5 132163 101FPMG2 E.83 132565 115804SP G.19
129980 ACR9A1H3 H.35 130069 IUCI-B211 G.5 132170 IPA1-N211B E.85 132566 1158029-01GI G.19
129981 ACR12A0H84 H.12 130070 IUGK-B211 G.5 132171 IPA1-P211B E.85 132567 1158029-02GI G.19
129981 ACR12A0H84 H.35 130071 IUGJ-B211 G.5 132172 IPB1-N211B E.85 132568 1158029-03GIT G.19
129982 ACR18A0H56 H.12 130072 IUGE-B211 G.5 132173 IPB1-P211B E.85 132569 1158029-04GIT G.19
129982 ACR18A0H56 H.35 130073 IUCE-B211 G.5 132174 IPA2-N211B E.85 132570 115MA G.19
129983 ACR27A0H37 H.12 130074 IUGL-B211 G.5 132175 IPA2-P211B E.85 132571 115CA G.19
129983 ACR27A0H37 H.35 130075 IUCL-B211 G.5 132176 IPB2-N211B E.85 133170 VB1203B C.17
129984 ACR35A0H27 H.12 130076 IUGT-B111 G.5 132177 IPB2-P211B E.85 133264 LG0404R1B0 D.19
129984 ACR35A0H27 H.35 130077 IUCT-B111 G.5 132184 IPA1-N222B E.85 133265 LG0406R1B0 D.19
129985 ACR55A0H18 H.35 130078 IUGP-B111 G.5 132185 IPA1-D222B E.85 133370 KVP75I D.21
129986 ACR70A0H14 H.35 130079 IUCP-B111 G.5 132186 IPB1-N222B E.85 133371 KVP10I D.21
129987 ACR80A0H14 H.35 130080 IUGQ-B111 G.5 132187 IPB1-D222B E.85 133374 KVP10U D.21
129988
129989
ACR97A0H11
ACR3A8H1
H.35
H.4
130081
130082
IUCQ-B111
IUGA-B411
G.5
G.5
132188
132189
IPA2-N222B
IPA2-D222B
E.85
E.85
133378
133379
KVP75E
KVP85E
D.23
D.23
A
129989 ACR3A8H1 H.12 130083 IUCA-B411 G.5 132190 IPB2-N222B E.85 133380 KVP10E D.23
129989 ACR3A8H1 H.12 130084 IUGU-B411 G.5 132191 IPB2-D222B E.85 133611 LG2506R1B0 D.19
129989 ACR3ABH1 H.35 130085 IUCU-B411 G.5 132198 IPA1-N411B E.85 133885 VB1204B C.17
129990
129990
ACR4A5H1
ACR4A5H1
H.4
H.12
130086
130087
IUGR-B411
IUCR-B411
G.5
G.5
132200
132201
IPA1-R411B
IPB1-N411B
E.85
E.85
137566
137567
MG0004QAT0
MG0004RAT0
D.19
D.19
B
129990 ACR4A5H1 H.35 130088 IUGH-B411 G.5 132203 IPB1-R411B E.85 139138 RT12D C.63
129991 ACR6A3H4 H.4 130089 IUCH-B411 G.5 132204 IPA2-N411B E.85 139139 RT12F C.63
129991 ACR6A3H4 H.12 130090 IUGI-B411 G.5 132206 IPB2-N411B E.85 139140 RT12G C.63
129991
129992
ACR6A3H4
ACR10A2H
H.35
H.12
130091
130092
IUCI-B411
IUGK-B411
G.5
G.5
132213
132214
IPA1-N422B
IPA1-D422B
E.85
E.85
139141
139142
RT12H
RT12J
C.63
C.63
C
129992 ACR10A2H H.35 130093 IUGJ-B411 G.5 132215 IPB1-N422B E.85 150000
129993 ACR14A1H4 H.12 130094 IUGE-B411 G.5 132216 IPB1-D422B E.85 152002 P9XPN52002 E.10
129993 ACR14A1H4 H.35 130095 IUCE-B411 G.5 132217 IPA2-N422B E.85 152007 P9XPN52007 E.10
129994
129994
ACR18A1H1
ACR18A1H1
H.12
H.35
130096
130097
IUGL-B411
IUCL-B411
G.5
G.5
132218
132219
IPA2-D422B
IPB2-N422B
E.85
E.85
152008
152009
P9XPN52008
P9XPN52009
E.10
E.10
D
129995 ACR27A0H75 H.12 130098 IUGT-B311 G.5 132220 IPB2-D422B E.85 152010 P9XPN52010 E.10
129995 ACR27A0H75 H.35 130099 IUCT-B311 G.5 132230 105DTL220 E.88 152011 P9XPN52011 E.10
129996 ACR35A0H58 H.35 130100 IUGP-B311 G.5 132231 105DTL500 E.88 152012 P9XPN52012 E.10
129997
129998
ACR38A0H58
ACR45A0H45
H.35
H.35
130101
130102
IUCP-B311
IUGQ-B311
G.5
G.5
132232
132234
105DTL690
105 PT
E.88
E.88
152061
152111
P9XPN52061
P9XEM52111
E.10
E.10
E
130000 130103 IUCQ-B311 G.5 132234 105PT G.9 152112 P9XEM52112 E.10
130000 ISGA-B211 G.3 130104 IUGM-B311 G.5 132240 105 GIL E.89 152121 P9XET52121 E.10
130001 IMGA-B211 G.3 130105 IUCM-B311 G.5 132241 105 GIL 10 E.89 152130 P9XEC52130 E.10
130002
130003
ISGR-B211
IMGR-B211
G.3
G.3
130140
130141
IZMA-B211
IZMS-B211
G.6
G.6
132242
132243
105 CI
105 CI 10
E.89
E.89
152161
152170
P9XER52161
P9XER52170
E.10
E.10
F
130004 ISGH-B211 G.3 130142 IZMR-B211 G.6 132244 105 PM E.89 152293 P9XSM52293 E.10
130005 IMGH-B211 G.3 130143 IZMH-B211 G.6 132250 105GP1P220 E.88 152321 P9XSM52391 E.10
130006 ISGJ-B211 G.3 130144 IZMA-B311 G.6 132251 105GP1P220M E.88 152392 P9XSM52392 E.10
130007
130008
IMGJ-B211
ISGE-B211
G.3
G.3
130145
130146
IZMS-B311
IZMR-B311
G.6
G.6
132252
132253
105GP1P500
105GP1P500M
E.88
E.88
152393
152435
P9XSM52393
P9XSC52435
E.10
E.10
G
130009 IMGE-B211 G.3 130147 IZMH-B311 G.6 132500 115PC002 G.18 152436 P9XSC52436 E.10
130010 ISGL-B211 G.3 130310 090MI1 E.83 132501 115PC015 G.18 152497 P9XSC52497 E.10
130011 IMGL-B211 G.3 130310 090MI1 G.19 132502 115PC018 G.18 152498 P9XSC52498 E.10
130012
130013
ISGT-B111
IMGT-B111
G.3
G.3
130311
130311
090MI2
090MI2
E.83
G.19
132503
132504
115PC119
115PC2002
G.18
G.18
152502
152511
P9XPL52502
P9XPL52511
E.11
E.11
H
130014 ISGP-B111 G.3 130320 114FCT03 E.88 132505 115PC2015 G.18 152513 P9XPL52513 E.11
130015 IMGP-B111 G.3 130320 114FCT03 G.9 132506 115PC2119 G.18 152514 P9XPL52514 E.11
130016 ISGQ-B111 G.3 130321 114FCT03T E.88 132507 115PC002L G.18 152515 P9XPL52515 E.11
130017
130018
IMGQ-B111
ISGA-B411
G.3
G.3
130321
130400
114FCT03T
SLSI F BD22
G.9
G.22
132508
132509
115PC015L
115PC018
G.18
G.18
152530
152531
P9XPL52530
P9XPL52531
E.11
E.11
I
130019 IMGA-B411 G.3 130401 SLSI F UM22 G.22 132510 115PC119 G.18 152561 P9XPL52561 E.11
130020 ISGR-B411 G.3 130402 SLSI M BD22 L G.22 132511 115PC2002L G.18 152610 P9XLD52610 E.11
130021 IMGR-B411 G.3 130403 SLSP11 G.24 132512 115PC2015L G.18 152611 P9XLD52611 E.11
130022
130023
ISGH-B411
IMGH-B411
G.3
G.3
130404
130405
SLSP02
SLSP0210
G.24
G.24
132513
132514
115PC2018
115PC2119
G.18
G.18
152612
152613
P9XLD52612
P9XLD52613
E.11
E.11
X
130024 ISGJ-B411 G.3 130406 SLSM11 G.24 132515 115PC2018 G.18 152614 P9XLD52614 E.11
130025 IMGJ-B411 G.3 130407 SLSK11 G.23 132520 115PD970 G.18 152620 P9XLD52620 E.11
130026 ISGE-B411 G.3 130408 SLSK2001 G.23 132521 115PD15210 G.18 152621 P9XLD52621 E.11
130027 IMGE-B411 G.3 130409 SLSK0210 G.23 132522 115PD38350 G.18 152622 P9XLD52622 E.11
130028 ISGL-B411 G.3 130410 SLSER11 G.25 132523 115PD2970 G.18 153006 P9MPN53006 E.10
130029 IMGL-B411 G.3 130411 SLSEP11 G.25 132524 115PD215210 G.18 153007 P9MPN53007 E.10
130030 ISGT-B311 G.3 130412 SLSHG11 G.25 132525 115PD238350 G.18 153008 P9MPN53008 E.10
130031 IMGT-B311 G.3 130413 SLSHA11 G.25 132530 115PD970T G.18 153009 P9MPN53009 E.10

X.27
Control and Automation
Ref. no Cat. no Page Ref. no Cat. no Page Ref. no Cat. no Page Ref. no Cat. no Page
153010 P9MPN53010 E.10 167139 U20X2K2PS H.3 167460 U200F910TA2 H.13 168291 DCR270A0H18 H.36
153011 P9MPN53011 E.10 167139 U20X2K2PS H.7 167461 U200F928TA3 H.12 168292 DCR310A0H14 H.36
153012 P9MPN53012 E.10 167400 U201N00K4FS H.9 167461 U200F928TA3 H.13 168293 DCR400A0H13 H.36
153061 P9MPN53061 E.10 167400 U201N00K4FS H.12 167832 U2KF3016PR1 H.33 168294 DCR540A0H08 H.36
153111 P9MEM53111 E.10 167401 U201N00K7FS H.9 167833 U2KF3030PR1 H.33 168295 DCR650A0H07 H.36
153112 P9MEM53112 E.10 167401 U201N00K7FS H.12 167834 U2KF3032PR2 H.33 168296 DCR740A0H06 H.36
153121 P9MET53121 E.10 167402 U201N01K5FS H.9 167835 U2KF3058PR3 H.33 168297 DCR800A0H06 H.36
153130 P9MEC53130 E.10 167402 U201N01K5FS H.12 167836 U2KF3060PR2 H.33 168371 DCR32A0H78 H.12
153161 P9MER53161 E.10 167403 U201N02K2FS H.9 167837 U2KF309PRD3 H.33 168371 DCR32A0H78 H.36
153293 P9MSM53293 E.10 167403 U201N02K2FS H.12 167838 U2KF3096PR4 H.33 168372 DCR45A0H55 H.12
153391 P9MSM53391 E.10 167404 U203X00K7FS H.9 167978 PR3110STD H.33 168372 DCR45A0H55 H.36
153392 P9MSM53392 E.10 167404 U203X00K7FS H.12 167979 PR3120STD H.33 168373 DCR60A0H4 H.36
153393 P9MSM53393 E.10 167405 U203X01K5FS H.9 167980 PR3150STD H.33 168374 DCR80A0H3 H.36
By reference number

153435 P9MSC53435 E.10 167405 U203X01K5FS H.12 167981 PR3180STD H.33 168375 DCR100A0H24 H.36
153436 P9MSC53436 E.10 167406 U203X02K2FS H.9 167982 PR3280STD H.33 168376 DCR120A0H2 H.36
153497 P9MSC53497 E.10 167406 U203X02K2FS H.12 167983 PR3330STD H.33 168377 DCR150A017 H.36
153498 P9MSC53498 E.10 167407 U203X04K0FS H.9 167984 PR3380STD H.33 168378 DCR180A0H14 H.36
153501 P9MPL53502 E.11 167407 U203X04K0FS H.12 167985 PR3450STD H.33 168379 DCR220AH11 H.36
153511 P9MPL53511 E.11 167408 U203X05K5FS H.9 167986 PR3600STD H.33 168380 DCR18A2H9 H.12
153513 P9MPL53513 E.11 167408 U203X05K5FS H.12 167987 PR3750STD H.33 168380 DCR18A2H9 H.36
153514 P9MPL53514 E.11 167409 U203X07K5FS H.9 167988 PR3900STD H.33 168381 DCR25A2H1 H.12
153515 P9MPL53515 E.11 167409 U203X07K5FS H.12 168000 U2KN00K4S H.16 168381 DCR25A2H1 H.36
153530 P9MPL53530 E.11 167410 U203X11K0FS H.9 168001 U2KN00K7S H.16 168382 DCR32A1H6 H.12
153531 P9MPL53531 E.11 167410 U203X11K0FS H.12 168002 U2KN01K5S H.16 168382 DCR32A1H6 H.36
153561 P9MPL53561 E.11 167411 U201N00K4SS H.9 168003 U2KN02K2S H.16 168383 DCR40A1H2 H.36
153610 P9MLD53610 E.11 167411 U201N00K4SS H.12 168004 U2KN04K0S H.16 168384 DCR50A0H96 H.36
153611 P9MLD53611 E.11 167412 U201N00K7SS H.9 168005 U2KN05K5S H.16 168385 DCR60A0H82 H.36
153612 P9MLD53612 E.11 167412 U201N00K7SS H.12 168006 U2KN07K5S H.16 168386 DCR80A0H58 H.36
153613 P9MLD53613 E.11 167413 U201N01K5SS H.9 168007 U2KN11K0S H.16 168387 DCR4A5H7 H.12
153614 P9MLD53614 E.11 167413 U201N01K5SS H.12 168008 U2KN15K0S H.16 168388 DCR6A3H9 H.12
153621 P9MLD53621 E.11 167414 U201N02K2SS H.9 168009 U2KN18K5S H.16 168389 DCR9A2H4 H.12
153622 P9MLD53622 E.11 167414 U201N02K2SS H.12 168010 U2KN22K0S H.16 168390 DCR12A1H7 H.12
153623 P9MLD53620 E.11 167415 U203N00K4SS H.9 168011 U2KN30K0S H.16 168391 DCR18A1H0 H.12
A 154700
154701
P9DPL54700
P9DPL54701
E.11
E.11
167415
167416
U203N00K4SS
U203N00K7SS
H.12
H.9
168024
168025
U2KX00K4S
U2KX00K7S
H.16
H.16
168392
168393
DCR3A15H2
DCR4A9H2
H.12
H.12
154720 P9DPL54720 E.11 167416 U203N00K7SS H.12 168026 U2KX01K5S H.16 168394 DCR6A6H8 H.12
154721 P9DPL54721 E.11 167417 U203N01K5SS H.9 168027 U2KX02K2S H.16 168395 DCR9A4H0 H.12
160000 167417 U203N01K5SS H.12 168028 U2KX04K0S H.16 168471 ACFR10A H.37
B 167075
167075
U20N0K2S
U20N0K2S
H.3
H.6
167418
167418
U203N02K2SS
U203N02K2SS
H.9
H.12
168029
168030
U2KX05K5S
U2KX07K5S
H.16
H.16
168472
168473
ACFR14A
ACFR18A
H.37
H.37
167076 U20N0K4S H.3 167419 U203N04K0SS H.9 168031 U2KX11K0S H.16 168474 ACFR27A H.37
167076 U20N0K4S H.6 167419 U203N04K0SS H.12 168032 U2KX15K0S H.16 168475 ACFR35A H.37
167077 U20N0K7S H.3 167420 U203N05K5SS H.9 168033 U2KX18K5S H.16 168476 ACFR38A H.37
C 167077
167078
U20N0K7S
U20N1K5S
H.6
H.3
167420
167422
U203N05K5SS
U203N07K5SS
H.12
H.9
168034
168035
U2KX22K0S
U2KX30K0S
H.16
H.16
168477
168478
ACFR45A
ACFR62A
H.37
H.37
167078 U20N1K5S H.6 167422 U203N07K5SS H.12 168036 U2KX37K0S H.16 168479 ACFR90A H.37
167079 U20N2K2S H.3 167424 U203X00K7SS H.9 168037 U2KX45K0S H.16 168480 ACFR115A H.37
167079 U20N2K2S H.6 167424 U203X00K7SS H.12 168038 U2KX55K0S H.16 168481 ACFR160A H.37
D 167080
167080
U20X0K7S
U20X0K7S
H.3
H.6
167425
167425
U203X01K5SS
U203X01K5SS
H.9
H.12
168039
168040
U2KX75K0S
U2KX90K0S
H.16
H.16
168482
168483
ACFR185A
ACFR225A
H.37
H.37
167081 U20X1K5S H.3 167426 U203X02K2SS H.9 168041 U2KX110KS H.16 168484 ACFR300A H.37
167081 U20X1K5S H.6 167426 U203X02K2SS H.12 168042 U2KX132KS H.16 168485 ACFR360A H.37
167082 U20X2K2S H.3 167427 U203X04K0SS H.9 168043 U2KX160KS H.16 168486 ACFR460A H.37
E 167082
167084
U20X2K2S
U20AF2K2X
H.6
H.4
167427
167428
U203X04K0SS
U203X05K5SS
H.12
H.9
168044
168045
U2KX200KS
U2KX250KS
H.16
H.16
168487
168488
ACFR550A
ACFR625A
H.37
H.37
167085 U20AF0K7 H.4 167428 U203X05K5SS H.12 168046 U2KX315KS H.16 168489 ACFR700A H.37
167086 U20AF2K2 H.4 167429 U203X07K5SS H.9 168047 U2KV23SL8 H.17 170000
167087 U20AR0K7 H.4 167429 U203X07K5SS H.12 168048 U2KV23SL7 H.17 170198 080CPT E.36
F 167088
167088
U20N0K2P
U20N0K2P
H.3
H.7
167430
167430
U203X11K0SS
U203X11K0SS
H.9
H.12
168049
168050
U2KV23SL9
U2KV23RY1
H.17
H.17
170212
170790
080ESL
P9ASCGT
E.37
E.36
167089 U20N0K4P H.3 167433 U200APB H.9 168052 U2KN37K0S H.16 170801 080SP1 E.32
167089 U20N0K4P H.7 167434 U200ADN H.9 168083 U2KV23DBUH4 H.34 170802 080SP2 E.32
167090 U20N0K7P H.3 167435 U200ARS485 H.9 168084 U2KV23DBUH1 H.34 170803 080SP3 E.32
G 167090
167091
U20N0K7P
U20N1K5P
H.7
H.3
167436
167437
U200ARS232
U200AMP
H.9
H.9
168085
168086
U2KV23DBUH2
U2KV23DBUH3
H.34
H.34
170804
170806
080SP4
080SP6
E.32
E.32
167091 U20N1K5P H.7 167438 U200ALEDK H.9 168087 U2KV23DN1 H.17 170807 080SP8 E.32
167092 U20N2K2P H.3 167439 U200ALCDK H.9 168088 U2KV23DN2 H.17 170808 080SP12 E.32
167092 U20N2K2P H.7 167440 U200ABK H.9 168089 U2KV23DN3 H.17 170809 080SP18 E.32
H 167093
167093
U20X0K7P
U20X0K7P
H.3
H.7
167441
167442
U200AW05
U200AW10
H.9
H.9
168090
168091
U2KV23RY0
U2KV23PI0
H.17
H.17
170810
170811
080SP24
080SP35
E.32
E.32
167094 U20X1K5P H.3 167443 U200AW20 H.9 168092 U2KV23SL0 H.17 170831 080SP1M E.32
167094 U20X1K5P H.7 167444 U200AW30 H.9 168093 U2KV23SL6 H.17 170832 080SP2M E.32
167095 U20X2K2P H.3 167445 U200AW50 H.9 168098 U2KV23DBUL1 H.34 170834 080SP4M E.32
I 167095
167132
U20X2K2P
U20N0K2PS
H.7
H.3
167453
167453
U200F611TA1
U200F611TA1
H.12
H.13
168099
168100
U2KV23DBUL2
U2KV23DBUL3
H.34
H.34
170835
170835
080SP1SFC
080SP1SFC
E.32
E.68
167132 U20N0K2PS H.7 167454 U200F627TA2 H.12 168102 U2KV23W103 H.17 170836 080SP1SFE E.32
167133 U20N0K4PS H.3 167454 U200F627TA2 H.12 168103 U2KV23W101 H.17 170837 080SP1SF E.32
167133 U20N0K4PS H.7 167454 U200F627TA2 H.12 168104 U2KV23W123 H.17 170837 080SP1SF E.68
X 167134
167134
U20N0K7PS
U20N0K7PS
H.3
H.7
167454
167456
U200F627TA2
U200F709TA1
H.13
H.12
168105
168106
U2KV23W113
U2KV23CNVKIT
H.17
H.17
170838
170838
080SP1MSFC
080SP1MSFC
E.32
E.68
167135 U20N1K5PS H.3 167456 U200F709TA1 H.13 168260 N11P3401806 H.37 170839 080SP1MSFE E.32
167135 U20N1K5PS H.7 167457 U200F719TA2 H.12 168261 N11P3401807 H.37 170840 080SP1MSF E.32
167136 U20N2K2PS H.3 167457 U200F719TA2 H.13 168285 ACR700A0H035 H.35 170840 080SP1MSF E.68
167136 U20N2K2PS H.7 167458 U200F739TA3 H.12 168286 DCR100A0H49 H.36 170841 080SP2SFC E.32
167137 U20X0K7PS H.3 167458 U200F739TA3 H.13 168287 DCR125A0H40 H.36 170841 080SP2SFC E.68
167137 U20X0K7PS H.7 167459 U200F905TA1 H.12 168288 DCR140A0H32 H.36 170842 080SP2SFE E.32
167138 U20X1K5PS H.3 167459 U200F905TA1 H.13 168289 DCR180A0H25 H.36 170843 080SP2SF E.32
167138 U20X1K5PS H.7 167460 U200F910TA2 H.12 168290 DCR210A0H25 H.36 170843 080SP2SF E.68

X.28
Control and Automation
Ref. no Cat. no Page Ref. no Cat. no Page Ref. no Cat. no Page Ref. no Cat. no Page
170844 080SP2MSFC E.32 180003 077-01 E.67 180603 077SLH11SC E.53 180930 077M4S4SY88 E.57
170844 080SP2MSFC E.68 180004 077-11D E.67 180604 077SLI11 E.53 180931 077M4T4TY88 E.57
170845 080SP2MSFE E.32 180005 077-10D E.67 180605 077SLI11DC E.53 180932 077M4T4SY88 E.57
170846 080SP2MSF E.32 180006 077-01D E.67 180606 077SLX22 E.53 180933 077M4S4TY88 E.57
170846 080SP2MSF E.68 180007 077-10A E.67 180607 077SLB11 E.53 180980 077GG03 E.58
170847 080SP3SFC E.32 180008 077-01R E.67 180608 077SLB11SC E.53 180980 077GG03 E.64
170847 080SP3SFC E.68 180009 099SPDTDB E.67 180609 077SLB11DC E.53 180981 077GGM E.58
170848 080SP3SFE E.32 180010 077GSBCN E.50 180610 077SLB11RC E.53 180981 077GGM E.64
170849 080SP3SF E.32 180019 077P11 E.50 180611 077SLE11 E.53 180982 077GGT E.58
170849 080SP3SF E.68 180020 077GGBCN E.50 180612 077SLE11SC E.53 180982 077GGT E.64
170850 080SP4SFE E.32 180029 077P10 E.50 180613 077SLE11DC E.53 181000 077MTS2422B E.57
170851 080SP4MSFE E.32 180030 077GEBCN E.50 180614 077SLE11RC E.53 181001 077MT24S22B E.57

By reference number
170852 080SP6SFE E.32 180039 077P01 E.50 180619 077SLU22 E.53 181002 077MTS2422RB E.57
170853 080SP8SFC E.32 180040 077GSBCS E.50 180620 077SLU22SC E.53 181003 077MT24S22RB E.57
170853 080SP8SFC E.68 180049 077E11 E.51 180621 077SLU22DC E.53 181004 077MTS123422B E.57
170854 080SP8SFE E.32 180050 077GGBCS E.50 180622 077SLU22RC E.53 181005 077MT1234S22B E.57
170855 080SP8SF E.32 180059 077E10 E.51 180623 077SLZ22 E.53 181006 077MT123S422B E.57
170855 080SP8SF E.68 180060 077GEBCS E.50 180624 077SLZ22SC E.53 181007 077MT234S122B E.57
170856 080SP12SFC E.32 180069 077E01 E.51 180625 077SLZ22DC E.53 181008 077M2S2SX44B E.57
170856 080SP12SFC E.68 180079 077RE11 E.51 180626 077SLZ22RC E.53 181009 077M2T2TX44B E.57
170857 080SP12SFE E.32 180089 077RE10 E.51 180630 077SCD1101 E.54 181010 077M2T2SX44B E.57
170858 080SP12SF E.32 180090 077RER E.51 180631 077SCD1105 E.54 181011 077M2S2TX44B E.57
170858 080SP12SF E.68 180099 077RE01 E.51 180632 077SCD1109 E.54 181012 077M2S2SY44B E.57
170859 080SP18SFC E.32 180100 077PC11C E.51 180634 077SCH1103 E.54 181013 077M2T2TY44B E.57
170859 080SP18SFC E.68 180101 077PC11E E.51 180636 077SCH11SC03 E.54 181014 077M2T2SY44B E.57
170860 080SP18SFE E.32 180102 077PC11F E.51 180637 077SCI1103 E.54 181015 077M2S2TY44B E.57
170861 080SP18SF E.32 180104 077PC11G E.51 180638 077SCI1105 E.54 181016 077M4S4SX88B E.57
170861 080SP18SF E.68 180120 077P11T30 E.50 180639 077SCI1114 E.54 181017 077M4T4TX88B E.57
170862 080SP24SFE E.32 180121 077P11T180 E.50 180640 077SCI11DC03 E.54 181018 077M4T4SX88B E.57
170863 080SP35SFC E.32 180136 077GSBCF E.50 180650 077SCX2201 E.55 181019 077M4S4TX88B E.57
170863 080SP35SFC E.68 180137 077GGBCF E.50 180651 077SCX2202 E.55 181020 077M4S4SY88B E.57
170864 080SP35SFE E.32 180138 077GEBCF E.50 180652 077SCX2204 E.55 181021 077M4T4TY88B E.57
170865 080SP35SF E.32 180180 077SHN11 E.52 180653 077SCX2205 E.55 181022 077M4T4SY88B E.57
170865
170883
080SP35SF
080KCSP
E.68
E.32
180190
180200
077SHN11SC
077SIN11
E.52
E.52
180666
180840
077SCX2228
077SCB1101
E.55
E.54
181023
181040
077M4S4TY88B
077PLM11D0
E.57
E.58
A
170883 080KCSP E.68 180210 077SIN11DC E.52 180841 077SCB1103 E.54 181041 077PLM20D0 E.58
173033 077CF73033 E.38 180240 077SBN11SC E.52 180842 077SCB1105 E.54 181042 077PLM02D0 E.58
173034 077CF73034 E.38 180250 077SBN11DC E.52 180843 077SCB1120 E.54 181043 077PLM10D0 E.58
173037
173038
077CF73037
077CF73038
E.38
E.38
180260
180270
077SBN11RC
077SEN11
E.52
E.52
180844
180845
077SCB1109
077SCB1114
E.54
E.54
181045
181047
077PLM10RJ
077PLM10RN
E.58
E.58
B
173040 077CF73040 E.38 180280 077SEN11SC E.52 180846 077SCB1107 E.54 181060 077ISD11D0 E.59
173095 077C3095 E.38 180290 077SEN11DC E.52 180848 077SCB11SC03 E.55 181063 077ISD10D0 E.59
173095 077C3095 E.64 180300 077SEN11RC E.52 180852 077SCB11DC07 E.55 181064 077ISD01D0 E.59
173208
173333
080CPDT
077CF73033
E.21
E.64
180440
180450
077SUN22
077SUN22SC
E.52
E.52
180853
180882
077SCB11RC03
077SCU2201
E.55
E.54
181170
181172
077ISB11D0
077ISZ11D0
E.60
E.60
C
173334 077CF73034 E.64 180460 077SUN22DC E.52 180883 077SCU2203 E.54 181174 077ISB11D0RC E.60
173337 077CF73037 E.64 180470 077SUN22RC E.52 180884 077SCU2205 E.54 181176 077ISZ11D0RC E.60
173338 077CF73038 E.64 180480 077SZN22 E.52 180885 077SCU2207 E.54 181260 077DLE14 E.62
173353
173455
077C3353
077CR455
E.38
E.38
180490
180500
077SZN22SC
077SZN22DC
E.52
E.52
180886
180888
077SCU2209
077SCU2220
E.54
E.54
181290
181300
077DLB15
077LDNV0
E.62
E.61
D
173901 077C9901 E.38 180510 077SZN22RC E.52 180889 077SCU22SC05 E.55 181301 077LRNVJ E.61
173902 077C9902 E.38 180521 077SP1 E.68 180890 077SCU22SC03 E.55 181302 077LRNVN E.61
173903 077C9903 E.38 180522 077SP1M E.68 180891 077SCU22SC14 E.55 181303 077LREVJ E.61
173904
173905
077C9904
077C9905
E.38
E.38
180523
180524
077SP2
077SP2M
E.68
E.68
180892
180893
077SCU22DC01
077SCU22DC03
E.55
E.55
181304
181305
077LREVL
077LDMVD
E.61
E.61
E
173910 077C9910 E.38 180525 077SP3 E.68 180894 077SCU22DC07 E.55 181350 077L2 E.62
173916 077C9916 E.38 180526 077SP4V E.68 180895 077SCU22RC03 E.55 181351 077L4 E.62
173919 077C9919 E.38 180527 077SP4 E.68 180896 077SCZ2201 E.54 181377 077GL2B E.62
179353
179510
077C3353
080XTGR03
E.64
E.39
180528
180529
077SP6
077SP9
E.68
E.68
180899
180900
077SCZ2207
077SCZ2209
E.54
E.54
181387
181550
077GL4B
077DPP
E.62
E.63
F
179511 080XTG803 E.39 180530 077SP12 E.68 180902 077SCZ2220 E.54 181553 077DIM E.63
179514 080XTGR E.39 180531 077SP16 E.68 180903 077SCZ22SC05 E.55 181554 077DAE E.63
179515 080XTG8 E.39 180532 077SP20 E.68 180904 077SCZ22SC03 E.55 181555 077DRR E.63
179525
179526
080XTGR01
080XTGR02
E.39
E.39
180533
180534
077SP25
077SP30
E.68
E.68
180905
180906
077SCZ22SC14
077SCZ22DC01
E.55
E.55
181556
181557
077GGBCR
077DAMP
E.63
E.63
G
179527 080XTGR04 E.39 180535 077SP36 E.68 180907 077SCZ22DC03 E.55 181570 077OPZ E.63
179528 080XTGR05 E.39 180536 077SP1SFE E.68 180908 077SCZ22DC07 E.55 181588 077CPT E.63
179529 080XTGR06 E.39 180537 077SP1MSFE E.68 180909 077SCZ22RC03 E.55 181600 077CPLT E.63
179530
179531
080XTGR07
080XTGR08
E.39
E.39
180538
180539
077SP2SFE
077SP2MSFE
E.68
E.68
180910
180911
077MTS2422
077MT24S22
E.57
E.57
181601
181602
077TPF
077ECR
E.63
E.51
H
179535 080XTG801 E.39 180540 077SP3SFE E.68 180912 077MTS2422R E.57 181603 077CST E.63
179536 080XTG802 E.39 180541 077SP4VSFE E.68 180913 077MT24S22R E.57 181604 077LPS E.63
179537 080XTG804 E.39 180542 077SP4SFE E.68 180914 077MTS123422 E.57 181605 077CSLN E.63
179538
179539
080XTG805
080XTG806
E.39
E.39
180543
180544
077SP6SFE
077SP9SFE
E.68
E.68
180915
180916
077MT1234S22
077MT123S422
E.57
E.57
181606
181608
077CSCN
077PTB10
E.63
E.67
I
179540 080XTG807 E.39 180545 077SP12SFE E.68 180917 077MT234S122 E.57 181609 077PTB01 E.67
179541 080XTG808 E.39 180546 077SP16SFE E.68 180918 077M2S2SX44 E.57 181610 077GS01 E.64
179901 077C9901 E.64 180547 077SP20SFE E.68 180919 077M2T2TX44 E.57 181611 077GS02 E.64
179902
179903
077C9902
077C9903
E.64
E.64
180548
180549
077SP25SFE
077SP30SFE
E.68
E.68
180920
180921
077M2T2SX44
077M2S2TX44
E.57
E.57
181612
181613
077GS03
077GG01
E.64
E.64
X
179904 077C9904 E.64 180550 077SP36SFE E.68 180922 077M2S2SY44 E.57 181614 077GG02 E.64
179905 077C9905 E.64 180551 077SP4VSFC E.68 180923 077M2T2TY44 E.57 181615 077PTB11 E.67
179910 077C9910 E.64 180552 077SP36SFC E.68 180924 077M2T2SY44 E.57 181618 077GE01 E.64
179916 077C9916 E.64 180552 077SP36SFC E.68 180925 077M2S2TY44 E.57 181619 077GE02 E.64
179919 077C9919 E.64 180553 077SP4VSF E.68 180926 077M4S4SX88 E.57 181620 077GE35 E.63
180000 180554 077SP36SF E.68 180927 077M4T4TX88 E.57 181621 099CH1 E.64
180001 077-11 E.67 180601 077SLD11 E.53 180928 077M4T4SX88 E.57 181622 077CF73040 E.64
180002 077-10 E.67 180602 077SLH11 E.53 180929 077M4S4TX88 E.57 181630 077BA15D24 E.65

X.29
Control and Automation
Ref. no Cat. no Page Ref. no Cat. no Page Ref. no Cat. no Page Ref. no Cat. no Page
181631 077BA15D30 E.65 185710 P9XMB2F E.19 187013 P9B10FN E.22 187230 P9ARBSV 026 E.34
181632 077BA15D60 E.65 185711 P9XMB2T E.19 187014 P9B01FH E.22 187231 P9ARBSN 027 E.34
181633 077BA15D60 E.65 185712 P9XMB2A E.19 187015 P9B10FH E.22 187232 P9ARBSV 027 E.34
181634 077BA15D130 E.65 185713 P9XMB2B E.19 187017 P9B01BN E.27 187233 P9ARBSN 031 E.34
181635 077BA15D140 E.65 185720 P9XMN4F E.19 187018 P9B10BN E.27 187234 P9ARBSV 031 E.34
181636 077BA15D220 E.65 185721 P9XMN4T E.19 187020 P9PDNV0 E.23 187235 P9ARBSN 032 E.34
181637 077BA15D230 E.65 185740 P9XMB4F E.19 187021 P9PRLVJ E.23 187236 P9ARBSV 032 E.34
181640 099E5,56 E.65 185741 P9XMB4T E.19 187022 P9PRDVN E.23 187237 P9ARBSN 001 E.34
181641 099E5,512 E.65 185770 P9XWR E.20 187023 P9PRNVJ E.23 187238 P9ARBSV 001 E.34
181642 099E5,524 E.65 185771 P9XRG E.20 187024 P9PRNVN E.23 187239 P9ARBSN 002 E.34
181650 077TNA E.66 185772 P9XZ E.20 187025 P9PREVJ E.23 187240 P9ARBSV 002 E.34
181660 077TNA2 E.66 185773 P9XBD E.20 187026 P9PREVL E.23 187241 P9ARBSN 005 E.34
181670 077TNA3 E.66 185774 P9XBM E.20 187027 P9PDTV0 E.23 187242 P9ARBSV 005 E.34
By reference number

181680 077TNA4 E.66 185784 P9YSCZ0C95 E.26 187028 P9PRTVN E.23 187245 P9ARBSN 030 E.34
181700 077TNC E.66 185788 080QDF027 E.35 187040 P9PDMVD E.23 187246 P9ARBSV 030 E.34
181710 077TNCS E.66 185789 080QDF030 E.35 187041 P9PDMVJ E.23 187247 P9ARBSR 201 E.34
181720 077TGR E.66 185920 P9YEM4RN E.25 187055 P9PDNF0 E.23 187248 P9ARBSN 202 E.34
181730 099E1430 E.65 185921 P9YER4RA E.25 187056 P9PDHF E.22 187249 P9ARBSV 202 E.34
181731 099E1440 E.65 185960 P9YSMD0N E.26 187056 P9PDHF E.23 187250 P9ARBSN 029 E.34
181732 099E1460 E.65 185962 P9YSMZ0N E.26 187070 P9PDNB0 E.27 187251 P9ARBSB 028 E.34
181733 099E14160 E.65 185965 P9YSMZ3N E.26 187071 P9PRLBJ E.27 187252 P9ARBSB 006 E.34
181734 099E14220 E.65 185970 P9YSCD0A95 E.26 187072 P9PRDBN E.27 187301 P9ARDLS029 E.35
181735 099E14250 E.65 185972 P9YSCD0K95 E.26 187073 P9PRNBJ E.27 187302 P9ARDLS028 E.35
181736 099E14260R E.65 185980 P9YSCZ0T95 E.26 187074 P9PRNBN E.27 187303 P9ARDLS035 E.35
181840 077TNA40 E.66 185987 P9YSCZ3C95 E.26 187110 P9ARBGR 029 E.34 187304 P9ARDLS038 E.35
181841 077TNA41 E.66 186031 P9SEM3R E.13 187111 P9ARBGN 028 E.34 187305 P9ARDLS006 E.35
181842 077TNA42 E.66 186061 P9SET4R E.13 187112 P9ARBGV 028 E.34 187306 P9ARDLS012 E.35
181843 077TNA43 E.66 186072 P9SER4RA E.13 187113 P9ARBGN 035 E.34 187307 P9ARDLS013 E.35
181844 077TNA44 E.66 186073 P9SEC4RA95 E.13 187114 P9ARBGV 035 E.34 187308 P9ARDLS014 E.35
181845 077TNA45 E.66 186120 P9SSMI0N E.14 187115 P9ARBGN 038 E.34 187309 P9ARDLS017 E.35
181846 077TNA46 E.66 186140 P9SSMD5N E.14 187116 P9ARBGV 038 E.34 187310 P9ARDLS018 E.35
181847 077TNA47 E.66 186150 P9SSMI5N E.14 187117 P9ARBGN 006 E.34 187311 P9ARDLS026 E.35
181848 077TNA48 E.66 186170 P9SSME0N E.14 187118 P9ARBGV 006 E.34 187312 P9ARDLS027 E.35
A 181849
181850
077TNA49
077TNA50
E.66
E.66
186190
186210
P9SSMU0N
P9SSME1N
E.14
E.14
187119
187120
P9ARBGN 012
P9ARBGV 012
E.34
E.34
187313
187314
P9ARDLS031
P9ARDLS032
E.35
E.35
181851 077TNA52 E.66 186230 P9SSMU1N E.14 187121 P9ARBGN 013 E.34 187315 P9ARDLS001 E.35
181852 077TNA53 E.66 186240 P9SSMZ1N E.14 187122 P9ARBGV 013 E.34 187316 P9ARDLS002 E.35
181853 077TNA54 E.66 186280 P9SSMZ5N E.14 187123 P9ARBGN 014 E.34 187317 P9ARDLS005 E.35
B 181854
181855
077TNA55
077TNA56
E.66
E.66
186320
186330
P9SSMZ3N
P9SSMX0N
E.14
E.14
187124
187125
P9ARBGV 014
P9ARBGN 017
E.34
E.34
187318
187319
P9ARDLS030
P9ARDLS201
E.35
E.35
181856 077TNA61 E.66 186360 P9SSMW0N E.14 187126 P9ARBGV 017 E.34 187320 P9ARDLS202 E.35
181857 077TNA59 E.66 186400 P9SSCD0A95 E.16 187127 P9ARBGN 018 E.34 187351 P9ARDPL029 E.35
181858 077TNA60 E.66 186402 P9SSCD0K95 E.16 187128 P9ARBGV 018 E.34 187352 P9ARDPL028 E.35
C 181930
181931
077TNA230
077TNA231
E.66
E.66
186403
186405
P9SSCI0C95
P9SSCI0N95
E.16
E.16
187129
187130
P9ARBGN 026
P9ARBGV 026
E.34
E.34
187353
187354
P9ARDPL035
P9ARDPL038
E.35
E.35
181932 077TNA232 E.66 186409 P9SSCD5A95 E.16 187131 P9ARBGN 027 E.34 187355 P9ARDPL006 E.35
181933 077TNA233 E.66 186410 P9SSCI5C95 E.16 187132 P9ARBGV 027 E.34 187356 P9ARDPL012 E.35
181934 077TNA234 E.66 186439 P9SSCZ0T95 E.16 187133 P9ARBGN 031 E.34 187357 P9ARDPL013 E.35
D 181951
181960
077TNA301
077TNA310
E.66
E.66
186461
186467
P9SSCZ5A95
P9SSCZ3C95
E.17
E.17
187134
187135
P9ARBGV 031
P9ARBGN 032
E.34
E.34
187358
187359
P9ARDPL014
P9ARDPL017
E.35
E.35
181961 077TNA311 E.66 186551 P9SEM3RL E.18 187136 P9ARBGV 032 E.34 187360 P9ARDPL018 E.35
181962 077TNA312 E.66 186561 P9SET4RL1 E.18 187137 P9ARBGN 001 E.34 187361 P9ARDPL026 E.35
181963 077TNA313 E.66 186695 P9SCD E.19 187138 P9ARBGV 001 E.34 187362 P9ARDPL027 E.35
E 184070
184071
P9MER3RN
P9MER4RN
E.13
E.13
186696
186697
P9SCB
P9SCC
E.19
E.19
187139
187140
P9ARBGN 002
P9ARBGV 002
E.34
E.34
187363
187364
P9ARDPL031
P9ARDPL032
E.35
E.35
184690 P9MPS21G E.19 186771 P9SRG E.20 187141 P9ARBGN 005 E.34 187365 P9ARDPL001 E.35
184691 P9MPS22G E.19 186772 P9SZ E.20 187142 P9ARBGV 005 E.34 187366 P9ARDPL002 E.35
184692 P9MPS23G E.19 186773 P9SBD E.20 187143 P9ARBGL 037 E.34 187367 P9ARDPL005 E.35
F 184693
184694
P9MPS34G
P9MPS35G
E.19
E.19
186774
186880
P9SBM
P9DPLNRG00
E.20
E.21
187144
187145
P9ARBGR 036
P9ARBGN 030
E.34
E.34
187368
187369
P9ARDPL030
P9ARDPL201
E.35
E.35
184695 P9MCD E.19 186881 P9DPLVRG00 E.21 187146 P9ARBGV 030 E.34 187370 P9ARDPL202 E.35
184696 P9MCB E.19 186882 P9DPLNRS00 E.21 187147 P9ARBGR 201 E.34 187490 P9ARCST E.36
184697 P9MCC E.19 186883 P9DPLVRS00 E.21 187148 P9ARBGN 202 E.34 187491 P9ARHPR E.37
G 184700
184701
P9MMN2F
P9MMN2T
E.19
E.19
186890
186891
P9DPLNRG01
P9DPLVRG01
E.21
E.21
187149
187150
P9ARBGV 202
P9ARBGN 029
E.34
E.34
187492
187510
P9ARRE4
P9ASBGR 029
E.37
E.34
184702 P9MMN2A E.19 186892 P9DPLNRS01 E.21 187151 P9ARBGB 028 E.34 187511 P9ASBGN 028 E.34
184703 P9MMN2B E.19 186893 P9DPLVRS01 E.21 187152 P9ARBGB 006 E.34 187512 P9ASBGV 028 E.34
184710 P9MMB2F E.19 186960 P9ZSMD0N E.26 187153 P9ARBGN 036 E.34 187513 P9ASBGN 035 E.34
H 184711
184712
P9MMB2T
P9MMB2A
E.19
E.19
186962
186965
P9ZSMZ0N
P9ZSMZ3N
E.26
E.26
187210
187211
P9ARBSR 029
P9ARBSN 028
E.34
E.34
187514
187515
P9ASBGV 035
P9ASBGN 038
E.34
E.34
184713 P9MMB2B E.19 186970 P9ZSCD0A95 E.26 187212 P9ARBSV 028 E.34 187516 P9ASBGV 038 E.34
184720 P9MMN4F E.19 186972 P9ZSCD0K95 E.26 187213 P9ARBSN 035 E.34 187517 P9ASBGN 006 E.34
184721 P9MMN4T E.19 186975 P9ZSCZ0C95 E.26 187214 P9ARBSV 035 E.34 187518 P9ASBGV 006 E.34
I 184740
184741
P9MMB4F
P9MMB4T
E.19
E.19
186980
186987
P9ZSCZ0T95
P9ZSCZ3C95
E.26
E.26
187215
187216
P9ARBSN 038
P9ARBSV 038
E.34
E.34
187519
187520
P9ASBGN 012
P9ASBGV 012
E.34
E.34
184770 P9MWR E.20 187000 P9B11VN E.22 187217 P9ARBSN 006 E.34 187521 P9ASBGN 013 E.34
184771 P9MRG E.20 187000 P9B11VN E.67 187218 P9ARBSV 006 E.34 187522 P9ASBGV 013 E.34
184772 P9MZ E.20 187001 P9B01VN E.22 187219 P9ARBSN 012 E.34 187523 P9ASBGN 014 E.34
X 185070
185071
P9XER3RN
P9XER4RN
E.13
E.13
187001
187002
P9B01VN
P9B10VN
E.67
E.22
187220
187221
P9ARBSV 012
P9ARBSN 013
E.34
E.34
187524
187525
P9ASBGV 014
P9ASBGN 017
E.34
E.34
185072 P9XER4RA E.13 187002 P9B10VN E.67 187222 P9ARBSV 013 E.34 187526 P9ASBGV 017 E.34
185695 P9XCD E.19 187003 P9B01VR E.22 187223 P9ARBSN 014 E.34 187527 P9ASBGN 018 E.34
185696 P9XCB E.19 187004 P9B10VA E.22 187224 P9ARBSV 014 E.34 187528 P9ASBGV 018 E.34
185697 P9XCC E.19 187008 P9B02VN E.22 187225 P9ARBSN 017 E.34 187529 P9ASBGN 026 E.34
185700 P9XMN2F E.19 187009 P9B20VN E.22 187226 P9ARBSV 017 E.34 187530 P9ASBGV 026 E.34
185701 P9XMN2T E.19 187010 P9B11T3 E.22 187227 P9ARBSN 018 E.34 187531 P9ASBGN 027 E.34
185702 P9XMN2A E.19 187011 P9B11T8 E.22 187228 P9ARBSV 018 E.34 187532 P9ASBGV 027 E.34
185703 P9XMN2B E.19 187012 P9B01FN E.22 187229 P9ARBSN 026 E.34 187533 P9ASBGN 031 E.34

X.30
Control and Automation
Ref. no Cat. no Page Ref. no Cat. no Page Ref. no Cat. no Page Ref. no Cat. no Page
187534 P9ASBGV 031 E.34 187842 P9ACFS5 E.37 188335 P9ACPBS335 E.39 202308 390/3927PFZCS630 C.86
187535 P9ASBGN 032 E.34 187843 P9ACDPP E.37 188336 P9ACPBS336 E.39 202309 390/3927PMRN C.86
187536 P9ASBGV 032 E.34 187844 P9ACVLR E.37 188804 P9ACA6 E.22 202310 390/392PMZI C.86
187537 P9ASBGN 001 E.34 187845 P9ACWAF E.37 188805 P9ARSN1 E.37 202311 390/3927PZ C.86
187538 P9ASBGV 001 E.34 187846 P9ACFSM E.22 188909 P9ARBGB 202 E.34 202323 39012Y110D C.84
187539 P9ASBGN 002 E.34 187846 P9ACFSM E.37 188978 P9ARBSB 202 E.34 202324 39012Y125D C.84
187540 P9ASBGV 002 E.34 187847 P9ACAFV E.37 189000 P9EPEG1 E.28 202325 39012Y197D C.84
187541 P9ASBGN 005 E.34 187850 BA9S606 E.38 189001 P9EPE01 E.28 202326 39012Y220D C.84
187542 P9ASBGV 005 E.34 187850 BA9S606 E.65 189002 P9EPE02 E.28 202327 39012Y24D C.84
187543 P9ASBGL 037 E.34 187851 BA9S615 E.38 189003 P9EPE03 E.28 202328 39012Y97D C.84
187544 P9ASBGR 036 E.34 187851 BA9S615 E.65 189004 P9EPE04 E.28 202437 3903Y110D C.84
187545 P9ASBGN 030 E.34 187851 BA9S615 G.19 189005 P9EPE06 E.28 202438 3903Y220D C.84

By reference number
187546 P9ASBGV 030 E.34 187852 BA9S122 E.38 189010 P9EPA01Y02 E.28 202479 3904Y110D C.84
187547 P9ASBGR 201 E.34 187852 BA9S122 E.65 189011 P9EPA01Y03 E.28 202480 3904Y125D C.84
187548 P9ASBGN 202 E.34 187852 BA9S122 G.19 189012 P9EPA01Y04 E.28 202481 3904Y197D C.84
187549 P9ASBGV 202 E.34 187853 BA9S242 E.38 189013 P9EPA01Y05 E.28 202482 3904Y220D C.84
187550 P9ASBGN 029 E.34 187853 BA9S242 E.65 189014 P9EPA01Y06 E.28 202483 3904Y24D C.84
187551 P9ASBGB 028 E.34 187853 BA9S242 G.19 189015 P9EPAG1Y01 E.28 202512 3905Y110D C.84
187552 P9ASBGB 006 E.34 187854 BA9S30 E.38 189016 P9EPA02Y01 E.29 202513 3905Y97D C.84
187553 P9ASBGN 036 E.34 187854 BA9S30 E.65 189017 P9EPA02Y02 E.29 202532 3906Y110D C.84
187610 P9ASBSR 029 E.34 187854 BA9S30 G.19 189018 P9EPA03Y01 E.29 202533 3906Y97D C.84
187611 P9ASBSN 028 E.34 187855 BA9S48 E.38 189019 P9EPA03Y02 E.29 202547 3907Y110D C.84
187612 P9ASBSV 028 E.34 187855 BA9S48 E.65 189020 P9EPA03Y03 E.29 202548 3907Y220D C.84
187613 P9ASBSN 035 E.34 187855 BA9S48 G.19 189021 P9EPA03Y04 E.29 202555 3908PFZCS400 C.86
187614 P9ASBSV 035 E.34 187856 BA9S6012 E.38 189022 P9EPA03Y05 E.29 202562 3908PFZCS800 C.86
187615 P9ASBSN 038 E.34 187856 BA9S6012 E.65 189023 P9EPA06Y01 E.29 202563 3908PMZ C.86
187616 P9ASBSV 038 E.34 187856 BA9S6012 G.19 189029 P9AEMT E.28 202564 3908PZ C.86
187617 P9ASBSN 006 E.34 187857 BA9S130 E.38 189030 P9AELN E.28 202565 3908Y110D C.84
187618 P9ASBSV 006 E.34 187857 BA9S130 E.65 189031 P9AELN202 E.28 202566 3908Y220D C.84
187619 P9ASBSN 012 E.34 187857 BA9S130 G.19 189032 P9AELN201 E.28 202572 3909Y110D C.84
187620 P9ASBSV 012 E.34 187860 BA9SN110 E.38 189033 P9AELN214 E.28 202654 390/3926PZ C.85
187621 P9ASBSN 013 E.34 187860 BA9SN110 E.65 189034 P9AELN215 E.28 204165 WKAT 35-1,2A/2V F.8
187622 P9ASBSV 013 E.34 187860 BA9SN110 G.19 189035 P9AELN205 E.28 204166 WKAT 70-1,2A/2V F.8
187623
187624
P9ASBSN 014
P9ASBSV 014
E.34
E.34
187861
187861
BA9SN220
BA9SN220
E.38
E.65
189036
189037
P9AELN206
P9AELN204
E.28
E.28
204166
204167
WKAT 70-1,2A/2V
WKAT 105-1,2A/2V
F.8
F.8
A
187625 P9ASBSN 017 E.34 188000 P9ARTBS E.38 189038 P9AELN203 E.28 204168 WKAT 140-1,2A/2V F.8
187626 P9ASBSV 017 E.34 188001 P9ARTBM E.38 189041 P9AELN006 E.28 204169 WKAT 35-10A/2V F.8
187627 P9ASBSN 018 E.34 188002 P9ARPBM E.39 189042 P9AELN028 E.28 204170 WKAT 70-10A/2V F.8
187628
187629
P9ASBSV 018
P9ASBSN 026
E.34
E.34
188005
188008
P9ARTWS
P9ARTWM
E.38
E.38
189043
189044
P9AELN029
P9AELN035
E.28
E.28
204171
204172
WKAT 105-10A/2V
WKAT 140-10A/2V
F.8
F.8
B
187630 P9ASBSV 026 E.34 188010 P9ASTBS E.38 189045 P9AELN038 E.28 204173 WKAT 210-10A/2V F.8
187631 P9ASBSN 027 E.34 188011 P9ASTWS E.38 189046 P9AELN039 E.28 204177 RSS13/64TA8,2 C.84
187632 P9ASBSV 027 E.34 188012 P9ARTTS E.38 189047 P9AELN042 E.28 204178 390/3924F5/2 C.85
187633
187634
P9ASBSN 031
P9ASBSV 031
E.34
E.34
188014
188015
P9ASTTS
P9ACPBS
E.38
E.39
189136
189137
P9EPL02X01
P9EPL02X02
E.30
E.30
204179
204180
3909F4/2
3909F5/2
C.86
C.86
C
187635 P9ASBSN 032 E.34 188016 P9ACPIU E.39 189138 P9EPL03X01 E.30 204181 3909Y197D C.84
187636 P9ASBSV 032 E.34 188017 P9ACPWS E.39 189138 P9EPL03X02 E.30 204800 C09479 C.21
187637 P9ASBSN 001 E.34 188018 P9ACPTS E.39 189140 P9EPL03X03 E.30 209344 LG0004P1B0 D.19
187638
187639
P9ASBSV 001
P9ASBSN 002
E.34
E.34
188019
188019
P9ARTTM
P9ARPTM
E.38
E.39
189141
189144
P9EPL04X01
P9EPA01Y02
E.31
E.28
209347
209780
LG0004S1B0
MG0004PAT0
D.19
D.19
D
187640 P9ASBSV 002 E.34 188028 P9ARPWM E.39 189152 P9AELN222 E.28 209781 MG0006PAT0 D.19
187641 P9ASBSN 005 E.34 188030 P9ACPBS039 E.39 189154 P9AELN224 E.28 210000
187642 P9ASBSV 005 E.34 188201 P9ACPBS201 E.39 189859 P9ASBGB 202 E.34 211107 3903Y230D C.84
187643
187645
P9ASBSL 037
P9ASBSN 030
E.34
E.34
188202
188203
P9ACPBS202
P9ACPBS203
E.39
E.39
189928
200000
P9ASBSB 202 E.34 211706
211708
39012Y230D
3904Y230D
C.84
C.84
E
187646 P9ASBSV 030 E.34 188204 P9ACPBS204 E.39 200004 LG0006P1B0 D.19 211709 3905Y230D C.84
187647 P9ASBSR 201 E.34 188205 P9ACPBS205 E.39 200254 077PC11DH E.51 211711 3906Y125D C.84
187648 P9ASBSN 202 E.34 188206 P9ACPBS206 E.39 200255 077PC11EH E.51 211712 3907Y230D C.84
187649
187650
P9ASBSV 202
P9ASBSN 029
E.34
E.34
188207
188208
P9ACPBS207
P9ACPBS208
E.39
E.39
200909
200910
114FCT12
114FCT21
G.9
G.9
211713
211714
3907Y125D
RSS13/64TA300
C.84
C.84
F
187651 P9ASBSB 028 E.34 188214 P9ACPBS214 E.39 200911 114FCT21T G.9 211714 RSS13/64TA300 C.84
187652 P9ASBSB 006 E.34 188215 P9ACPBS215 E.39 200912 114FCT30 G.9 211727 RSS13/64TA18 C.84
187701 080QDF029 E.35 188222 P9ACPBS222 E.39 202273 390/3921PFZCS14 C.85 211728 RSS13/64TA33 C.84
187702
187703
080QDF028
080QDF035
E.35
E.35
188224
188231
P9ACPBS224
P9ACPBS231
E.39
E.39
202274
202275
390/3921PFZCS45
390/3921PMRN
C.85
C.85
211730
211731
RSS13/64TA39
RSS13/64TA47
C.84
C.84
G
187704 080QDF038 E.35 188232 P9ACPBS232 E.39 202276 390/3921PMZI C.85 211735 RSS13/64TA5,6 C.84
187705 080QDF006 E.35 188233 P9ACPBS233 E.39 202277 390/3921PZ C.85 211737 RSS13/64TA15 C.84
187706 080QDF012 E.35 188234 P9ACPBS234 E.39 202278 390/3922PFZCS90 C.85 211739 RSS20/165TA470 C.84
187707
187708
080QDF013
080QDF014
E.35
E.35
188239
188243
P9ACPBS239
P9ACPBS243
E.39
E.39
202279
202280
390/3922PMZI
390/3922PZ
C.85
C.85
211742
211743
RSS13/64TA10
RSS13/64TA100
C.84
C.84
H
187709 080QDF017 E.35 188258 P9ACPBS258 E.39 202281 390/3923PFZCS125 C.85 211744 RSS13/64TA180 C.84
187710 080QDF018 E.35 188301 P9ACPBS301 E.39 202282 390/3923PMRN C.85 211745 RSS13/64TA330 C.84
187711 080QDF026 E.35 188302 P9ACPBS302 E.39 202283 390/3923PMZI C.85 211746 RSS13/64TA390 C.84
187713
187714
080QDF031
080QDF032
E.35
E.35
188303
188304
P9ACPBS303
P9ACPBS304
E.39
E.39
202284
202287
390/3923PZ
390/3924PFRN
C.85
C.85
211748
211770
RSS20/165TA390
3906Y230D
C.84
C.84
I
187715 080QDF001 E.35 188305 P9ACPBS305 E.39 202288 390/3924PFZCS125 C.85 212558 SFS04M B.4
187716 080QDF002 E.35 188306 P9ACPBS306 E.39 202289 390/3924PFZCS200 C.85 212559 SFS05M B.4
187717 080QDF005 E.35 188307 P9ACPBS307 E.39 202290 390/3924PMRN C.85 212677 077PC11CH E.51
187719
187720
080QDF201
080QDF202
E.35
E.35
188308
188309
P9ACPBS308
P9ACPBS309
E.39
E.39
202291
202292
390/3924PMZI
390/3924PZ
C.85
C.85
212693
212702
114FCT12T
RSS13/64TA220
G.9
C.84
X
187791 P9ASCST E.36 188316 P9ACPBS316 E.39 202295 390/3925PFZCS320 C.85 212705 3903Y48D C.84
187792 P9ASHP3 E.37 188317 P9ACPBS317 E.39 202297 390/3925PMRN C.85 212706 3905Y220D C.84
187793 P9ASHP5 E.37 188324 P9ACPBS324 E.39 202298 390/3925PMZI C.85 212707 3906Y48D C.84
187794 P9ASHAC E.37 188328 P9ACPBS328 E.39 202299 390/3925PZ C.85 212709 390/3922PFRN C.85
187795 P9ASEBG E.37 188331 P9ACPBS331 E.39 202303 390/3926PFZCS270 C.85 212959 3908Y97D C.84
187796 P9ADCST E.21 188332 P9ACPBS332 E.39 202304 390/3926PMZI C.85 212962 3909PMZ C.86
187840 P9ACRCL E.37 188333 P9ACPBS333 E.39 202306 390/3927PFRN C.86 213014 390/3922PMRN C.85
187841 P9ACFS3 E.37 188334 P9ACPBS334 E.39 202307 390/3927PFZCS320 C.86 213034 RSS13/64TA1200 C.84

X.31
Control and Automation
Ref. no Cat. no Page Ref. no Cat. no Page Ref. no Cat. no Page Ref. no Cat. no Page
213573 390/3925PFZCS150 C.85 220710 PRC4M20ABL A.3 222114 PRCM52 A.6 222335 BA15D24LB E.79
213574 390/3926PFZCS450 C.85 220711 PRC4M20ADL A.3 222115 PRCM53 A.6 222336 BA15D115LR E.79
213601 3904Y97D C.84 220712 PRC4M20AGL A.3 222116 PRCM91R A.6 222337 BA15D115LA E.79
213612 3906Y220D C.84 220713 PRC4M20CBL A.3 222120 PRCM93G A.6 222338 BA15D115LG E.79
213663 RSS20/165TA100 C.84 220714 PRC4M20CDL A.3 222121 PRCM71 A.6 222339 BA15D115LV E.79
213664 RSS20/165TA120 C.84 220715 PRC4M20AJL A.3 222122 PRCM73 A.6 222340 BA15D115LL E.79
213691 3903Y97D C.84 220716 PRC4M20CGL A.3 222126 PRCM91G A.6 222341 BA15D115LB E.79
213814 3904Y48D C.84 220717 PRC4M20ANL A.3 222230 NLT1R E.78 222342 BA15D230LR E.79
213962 SYDW B611 G.27 220718 PRC4M20CJL A.3 222231 NLT1A E.78 222343 BA15D230LA E.79
213964 SYDW B611S G.27 220754 PRC4M20DCBL A.3 222232 NLT1G E.78 222344 BA15D230LG E.79
213965 SYDW B711S G.27 220755 PRC4M20DCDL A.3 222233 NLT1V E.78 222345 BA15D230LV E.79
213986 390/3923PFRN C.85 220756 PRC4M20DCGL A.3 222234 NLT1L E.78 222346 BA15D230LL E.79
214066 3908Y197D C.84 220757 PRC4M20DCJL A.3 222235 NLT1I E.78 222347 BA15D230LB E.79
By reference number

214081 RSS20/165TA82 C.84 220912 PRCG-ES15/2N A.3 222236 NLT2BDR E.78 222348 BA15D125 E.79
214120 390/3921/2FOM4/2 C.85 220914 PRCG1052 A.3 222237 NLT2BDA E.78 222349 BA15D245 E.79
214121 390/3922FOM5/2 C.85 220915 PRCMS35 A.3 222238 NLT2BDG E.78 222350 BA15D305 E.79
214122 390/3923/2FOM4/2 C.85 220916 PRCTR1 A.3 222239 NLT2BDV E.78 222351 BA15D1155 E.79
214123 390/3923FOM5/2 C.85 221051 PRC4M30ABL A.3 222240 NLT2BDL E.78 222352 BA15D2305 E.79
214124 390/3924F4 C.85 221052 PRC4M30ADL A.3 222241 NLT2BDI E.78 223000 IPSF1 E.86
214126 390/3924M4/2 C.85 221053 PRC4M30AGL A.3 222242 NLT2AJR E.78 240000
214127 390/3924M5/2 C.85 221054 PRC4M30CBL A.3 222243 NLT2AJA E.78 241747 PVP85G D.19
214128 390/3925F4/2 C.85 221055 PRC4M30CDL A.3 222244 NLT2AJG E.78 241748 PVP10G D.19
214129 390/3925F5/2 C.85 221056 PRC4M30AJL A.3 222245 NLT2AJV E.78 241749 PCP12G D.19
214130 390/3925M4/2 C.85 221057 PRC4M30CGL A.3 222246 NLT2AJL E.78 241750 WLSD1 D.23
214131 390/3925M5/2 C.85 221058 PRC4M30ANL A.3 222247 NLT2AJI E.78 241751 WKI0910 D.21
214133 390/3926F4/2 C.85 221059 PRC4M30CJL A.3 222248 NLT2ANR E.78 241752 WKI0608 D.21
214134 390/3926F5/2 C.85 221074 PRC4M30DCBL A.3 222249 NLT2ANA E.78 242260 3905Y125D C.84
214135 390/3926M4/2 C.85 221075 PRC4M30DCDL A.3 222250 NLT2ANG E.78 242464 NLT2AJLI E.78
214136 390/3926M5/2 C.85 221076 PRC4M30DCGL A.3 222251 NLT2ANV E.78 243281 RSS13/64TA120 C.84
214137 390/3927F4/2 C.86 221077 PRC4M30DCJL A.3 222252 NLT2ANL E.78 243713 SFVH03 B.3
214138 390/3927F5/2 C.86 221442 PRCG-ES15/3N A.3 222253 NLT2ANI E.78 244056 3907Y40D C.84
214139 390/3927M4/2 C.86 221809 PRC4M40ABL A.3 222254 NLT3BDR E.78 244057 3907Y24D C.84
214140 390/3927M5/2 C.86 221810 PRC4M40ADL A.3 222255 NLT3BDA E.78 244058 3907Y20D C.84
A 214141
214142
3908/9M4/2
3908/9M5/2
C.86
C.86
221811
221812
PRC4M40AGL
PRC4M40CBL
A.3
A.3
222256
222257
NLT3BDG
NLT3BDV
E.78
E.78
244059
244063
3907Y197D
3906Y40D
C.84
C.84
214144 3908F4/2 C.86 221813 PRC4M40CDL A.3 222258 NLT3BDL E.78 244064 3906Y24D C.84
214145 3908F5/2 C.86 221814 PRC4M40AJL A.3 222259 NLT3BDI E.78 244065 3906Y20D C.84
214146 3909Y97D C.84 221815 PRC4M40CGL A.3 222260 NLT3AJR E.78 244066 3906Y197D C.84
B 214399
214400
RSS13/64TA270
RSS13/64TA820
C.84
C.84
221816
221817
PRC4M40ANL
PRC4M40CJL
A.3
A.3
222261
222262
NLT3AJA
NLT3AJG
E.78
E.78
244071
244072
3905Y40D
3905Y24D
C.84
C.84
214442 3903Y197D C.84 221851 PRC4M40DCBL A.3 222263 NLT3AJV E.78 244073 3905Y20D C.84
214580 RSS13/64TA680 C.84 221852 PRC4M40DCDL A.3 222264 NLT3AJL E.78 244074 3905Y197D C.84
214869 RSS13/64TA6,8 C.84 221853 PRC4M40DCGL A.3 222265 NLT3AJI E.78 244083 3904Y40D C.84
C 215004
215248
RSS20/165TA150
077PC11FH
C.84
E.51
221854
221860
PRC4M40DCJL
PRC1T10CBL
A.3
A.5
222266
222267
NLT3ANR
NLT3ANA
E.78
E.78
244084
244088
3904Y20D
3903Y40D
C.84
C.84
215278 3903Y20D C.84 221861 PRC1T10CDL A.5 222268 NLT3ANG E.78 244106 39012Y40D C.84
215320 1158065SPA G.19 221862 PRC1T10CJL A.5 222269 NLT3ANV E.78 244107 39012Y20D C.84
215321 1158067SPA G.19 221868 PRC1T10ADL A.5 222270 NLT3ANL E.78 244172 390/3921PFZCS25 C.85
D 215422
215432
114FCT30T
P9EPC01X00
G.9
E.30
221869
221870
PRC1T10AJL
PRC1T10ANL
A.5
A.5
222271
222272
NLT3ANI
NLT4BDR
E.78
E.78
244173
244191
390/3921PFRN
RSS13/64TA470
C.85
C.84
215433 P9EPC01X01 E.30 221875 PRC1T20CBL A.5 222273 NLT4BDA E.78 244192 RSS13/64TA27 C.84
216100 3903Y125D C.84 221876 PRC1T20CDL A.5 222274 NLT4BDG E.78 244734 39012Y48D C.84
216604 SFE04K1 B.4 221877 PRC1T20CJL A.5 222275 NLT4BDV E.78 244735 3903Y24D C.84
E 219154
220000
ERX00K7 H.13 221883
221884
PRC1T20ADL
PRC1T20AJL
A.5
A.5
222276
222277
NLT4BDL
NLT4BDI
E.78
E.78
244736
244737
3905Y48D
3907Y48D
C.84
C.84
220019 PRC2P20ABL A.4 221885 PRC1T20ANL A.5 222278 NLT73BD E.79 244738 3907Y97D C.84
220020 PRC2P20ADL A.4 221890 PRCT1CB A.5 222279 NLT77BD E.79 244739 3909Y220D C.84
220021 PRC2P20AGL A.4 221891 PRCT1CD A.5 222280 NLT77AJ E.79 244744 390/3922PFZCS45 C.85
F 220022
220023
PRC2P20CBL
PRC2P20CDL
A.4
A.4
221892
221896
PRCT1CJ
PRCT1AD
A.5
A.5
222281
222282
NLT77AN
NLT9TC
E.79
E.79
244745
244746
390/3923PFZCS75
390/3925PFRN
C.85
C.85
220024 PRC2P20AJL A.4 221897 PRCT1AJ A.5 222284 NLT5BT E.79 244983 3909PFZCS120 C.86
220025 PRC2P20CGL A.4 221898 PRCT1AN A.5 222285 NLT5ET E.79 244987 RSS20/165TA560 C.84
220026 PRC2P20ANL A.4 221905 PRCT2CB A.5 222286 NLT75BD E.79 245217 SFS04K1 B.4
G 220027
220041
PRC2P20CJL
PRC2P20DCBL
A.4
A.4
221906
221907
PRCT2CD
PRCT2CJ
A.5
A.5
222287
222288
NLT75AJ
NLT75AN
E.79
E.79
250000
254537 SFVB8 B.5
220042 PRC2P20DCDL A.4 221913 PRCT2AD A.5 222289 NLT2BDLR E.78 254537 SFVB8 B.19
220043 PRC2P20DCGL A.4 221914 PRCT2AJ A.5 222290 NLT2BDLA E.78 260000
220044 PRC2P20DCJL A.4 221915 PRCT2AN A.5 222291 NLT2BDLG E.78 264826 SFALPEN B.3
H 220216
220217
PRCZ8
PRCG8
A.4
A.4
221918
221920
PRCGZT80
PRCMS16
A.5
A.5
222292
222293
NLT2BDLV
NLT2BDLL
E.78
E.78
410000
414038 6KCV300CTI H.42
220218 PRCPZ11 A.4 221921 PRCTR A.5 222294 NLT2BDLI E.78 414066 6KCV301PDP33 H.42
220219 PRCR159 A.4 221934 PRCG-ES15/4N A.3 222295 NLT2AJLR E.78 414095 6KBU-300-85 H.42
220310 PRC3P30ABL A.4 222004 PRC1S13BDL A.5 222296 NLT2AJLA E.78 414141 6KBU-300-50 H.42
I 220311
220312
PRC3P30ADL
PRC3P30AGL
A.4
A.4
222007
222008
PRC1S13CBL
PRC1S13CDL
A.5
A.5
222297
222298
NLT2AJLG
NLT2AJLV
E.78
E.78
414158
414250
6KCV301ENC
6KAVI43F75Y1 _ _
H.42
H.42
220313 PRC3P30CBL A.4 222012 PRC1S13ANL A.5 222299 NLT2AJLL E.78 414251 6KAVI43001Y1 _ _ H.42
220314 PRC3P30CDL A.4 222013 PRC1S13BNL A.5 222301 NLT2ANLR E.78 414252 6KAVI43002Y1 _ _ H.42
220315 PRC3P30AJL A.4 222039 PRCW20 A.5 222302 NLT2ANLA E.78 414253 6KAVI43003Y1 _ _ H.42
X 220316
220317
PRC3P30CGL
PRC3P30ANL
A.4
A.4
222043
222100
PRCTR1S
PRCM21P
A.5
A.6
222303
222304
NLT2ANLG
NLT2ANLV
E.78
E.78
414254
414255
6KAVI43005Y1 _ _
6KAVI43007Y1 _ _
H.42
H.42
220318 PRC3P30CJL A.4 222101 PRCM21N A.6 222305 NLT2ANLL E.78 414256 6KAVI43010Y1 _ _ H.42
220335 PRC3P30DCBL A.4 222102 PRCM31R A.6 222306 NLT2ANLI E.78 414257 6KAVI43015Y1 _ _ H.42
220336 PRC3P30DCDL A.4 222103 PRCM32R A.6 222307 NLT90BT E.79 414258 6KAVI43020Y1 _ _ H.42
220337 PRC3P30DCGL A.4 222104 PRCM31G A.6 222330 BA15D24LR E.79 414259 6KAVI43025Y1 _ _ H.42
220338 PRC3P30DCJL A.4 222105 PRCM32G A.6 222331 BA15D24LA E.79 414260 6KAVI43030Y1 _ _ H.42
220647 PRCZ11 A.4 222106 PRCM33G A.6 222332 BA15D24LG E.79 414261 6KAVI43040Y1 _ _ H.42
220647 PRCZ11 F.7 222109 PRCM33R A.6 222333 BA15D24LV E.79 414262 6KAVI43050Y1 _ _ H.42
220648 PRCG11 A.4 222113 PRCM51 A.6 222334 BA15D24LL E.79 414263 6KAVI43060Y1 _ _ H.42

X.32
Control and Automation
Ref. no Cat. no Page
414264 6KAVI43025X1 _ _ H.42
414265 6KAVI43030X1 _ _ H.42
414266 6KAVI43040X1 _ _ H.42
414267 6KAVI43050X1 _ _ H.42
414268 6KAVI43060X1 _ _ H.42
414269 6KAVI43075X1 _ _ H.42
414270 6KAVI43100X1 _ _ H.42
414271 6KAVI43125X1 _ _ H.42
414272 6KAVI43150X1 _ _ H.42
414273 6KAVI43200X1 _ _ H.42
414332 6KCV301KPDMK H.42
414333 6KCV301D8R4 H.42

By reference number
414334 6KCV301D14A4 H.42
414335 6KCV301D20A6 H.42
414343 6KCV301DGF H.42
414352 6KCV301DNET H.42
414353 HE300GEN250 H.42
414371 6KCV8S8F59 H.42
414381 EMI-FFP 480-9 H.43
414382 EMI-FFP 480-24 H.43
414383 EMI-FFP 480-30 H.43
414385 COMP 480-42 H.43
414386 COMP 480-55 H.43
414387 COMP 480-75 H.43
414388 COMP 480-100 H.43
414389 COMP 480-130 H.43
414390 COMP 480-180 H.43
414391 RANGER 520-280 H.43
414392 RANGER 520-450 H.43
414397 COMP 520-7 H.43
414398 COMP 520-16 H.43
414399 COMP 520-30 H.43
414400 COMP 520-42 H.43
414401
414402
COMP 520-55
COMP 520-75
H.43
H.43
A
414403 COMP 520-100 H.43
414404 COMP 520-130 H.43
414405 COMP 520-180 H.43
414460 6KBU-300-20 H.42 B

I
The policy of GE Consumer &
Industrial is one of continuous
improvement. X
The right is reserved to alter the
design or any structural details of
the products at any time without
giving notice.

July 2005
GE Consumer & Industrial

X.33
Control and Automation
Notes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

X.34
GE Consumer & Industrial GE Consumer & Industrial

32764
Power Protection Power Protection

GE Consumer & Industrial


Control and Automation
Power Protection (formerly GE Power Controls),
a division of GE Consumer & Industrial,
is a first class European supplier of
low-voltage products including wiring
devices, residential and industrial electrical
distribution components, automation
products, enclosures and switchboards.
Demand for the company’s products
For industrial applications
comes from, wholesalers, installers,
panel-board builders, contractors, OEMs Everything is under control
and utilities worldwide.
www.gepowercontrols.com

Control and Automation


GE POWER CONTROLS
International Sales
Nieuwevaart 51
B-9000 Gent
Belgium
Tel. +32/9 265 21 11
Fax +32/9 265 28 90
E-mail: gepcbel@gepc.ge.com

GE POWER CONTROLS
Hornhouse Lane
Knowsley Industrial Park
Liverpool L33 7YQ
United Kingdom
Tel. 0800/587 1251
Fax 0800/587 1239
E-mail: gepcuk@gepc.ge.com

GE imagination at work GE imagination at work


680804
Ref. C/4506/E/EX 16.0 Ed. 07/05
© Copyright GE Power Controls 2005

Potrebbero piacerti anche