Sei sulla pagina 1di 100

INDEX

TURBINES
PK Turbine pumps with peripheral impeller, END SUCTION . . . . . . . . . . . . . . . . . . . . . . . . .2
PQ Turbine pumps with peripheral impeller, SIDE SUCTION . . . . . . . . . . . . . . . . . . . . . . . . .4
PQA Turbine pumps with peripheral impeller, SIDE SUCTION, PLASTIC – BRASS PUMP BODY . .8

CENTRIFUGAL
CP End suction centrifugal pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
AR End suction STAINLESS STEEL centrifugal pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
PNGA End suction 316 STAINLESS STEEL centrifugal pump . . . . . . . . . . . . . . . . . . . . . . . . . 20

MULTI STAGE
3-4 CP Multi-stage centrifugal pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
3-4 CR Multi-stage centrifugal pumps, STAINLESS STEEL PUMP BODY . . . . . . . . . . . . . . . . .24
VL Vertical Multi-stage Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
VLE Inline Multi-stage Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30

SELF PRIMING
PKS Self priming with peripheral impeller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
JSW Shallow well self priming jet pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
JCR Shallow well self priming jet pumps, STAINLESS STEEL PUMP BODY . . . . . . . . . . . .38
JD Self priming pump for deep well . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
PLURIJET Self priming MULTI-STAGE pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44

BRONZE
BZ Pump with bronze body . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
SUMP
TOP Sump pumps for clear water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
TOP FLOOR Sump pumps for clear water, LOW SUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
TOP VORTEX VORTEX Sump pumps for dirty water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
TOP MULTI MULTI-STAGE sump pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
RX STAINLESS STEEL sump pump for clear water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
RX VORTEX VORTEX stainless steel sump pump, for dirty water . . . . . . . . . . . . . . . . . . . . . . . . . . . .62

EFFLUENT
D Effluent pumps for dirty water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64

SEWAGE
VX Vortex sewage pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
VXS Vortex STAINLESS STEEL sewage pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
VXCH-M Vortex CAST IRON sewage pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
VXC-L Vortex CAST IRON sewage pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
MC Double channel sewage pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74
MCS Double channel STAINLESS STEEL sewage pumps . . . . . . . . . . . . . . . . . . . . . . . . . . .76
MCM Double channel CAST IRON sewage pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
MC-L Double channel CAST IRON sewage pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80

SUBMERSIBLE
4SK Submersible pump with peripheral impeller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82
SUMO Multi-stage submersible pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84
4BLOCK 4” Monoblock submersible pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
PK pumps with peripheral impeller

RANGE OF PERFORMANCE GUARANTEE 2 YEARS subject to our general terms of sale.


Flow rate up to 24 gpm
Head up to 328 ft CONSTRUCTION CHARACTERISTICS

LIMITS OF USE
• PUMP BODY: cast iron, with threaded ports.
• MOTOR BRACKET (patent nº 1289150): aluminium with brass
Manometric suction lift up to 26 ft insert; reduces starting difficulties due to seizure of the impeller after
Liquid temperature up to + 140°F long periods of inactivity.
Environment temperature up to + 104°F • IMPELLER: brass, of the type with radial peripheral vanes.
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
CONSTRUCTION AND SAFETY STANDARDS • MECHANICAL SEAL: ceramic - graphite - NBR.
EN 60 335-1 EN 60034-1 • ELECTRIC MOTOR: the pumps are close-coupled to a carefully
IEC 335-1 IEC 34-1 matched PEDROLLO electric motor, quiet running, totally
CEI 61-150 CEI 2-3 enclosed fan cooled (TEFC), suitable for continuous duty.
PK: single-phase 115 V or 230 V - 60Hz with capacitor and
thermal overload protector.
INSTALLATION AND USE PK: three-phase 230/460 V - 60 Hz.

They are recommended for pumping clean water without abrasive


• INSULATION: class F. • PROTECTION: IP 44.

particles and liquids that are chemically non aggressive to the materials
• REGISTERED MODEL nº 72753.

from which the pump is made.


OPTIONS ON REQUEST
FOR THEIR RELIABILITY, SIMPLICITY OF USE AND ECONOMY
THEY ARE SUITABLE FOR RESIDENTIAL USE AND IN ⇒ special mechanical seal
PARTICULAR FOR DISTRIBUTING WATER IN COMBINATION WITH ⇒ other voltages or frequency 50 Hz
SMALL PRESSURE SETS, FOR IRRIGATING GARDENS.
The pumps must be installed in enclosed places, or at least protected
against inclement weather.

2
CURVES AND PERFORMANCE DATA

PK 20

PK 15
PKH 07
PK 10

PK 07
PKH 05

Head H (meters)
Head H (feet)

PK 05
H

H
PK 03

Flow Rate Q Q

MODEL FLOW RATE GPM 0 1.2 2.7 4 5.5 6.6 8 9.3 10.2 13.2 15 18 21 23
HP
1 PH 3 PH FLOW RATE l/min 0 5 10 15 20 25 30 35 40 50 60 70 80 90
PK 03 PK 03 0.33 131 124 110 95 78 64 49 32 16
PK 05 PK 05 0.5 181 164 149 133 118 101 88 72 55 26
PKH 05 PKH 05 0.5 214 203 187 170 154 137 121 105 88 59
PK 07 PK 07 0.7 230 216 200 183 167 151 134 119 101 72
H Feet
PKH 07 PKH 07 0.7 296 269 233 197 160 124 88 55 16
PK 10 PK 10 1 279 262 246 229 213 197 180 164 147 114 82 49
PK 15 PK 15 1.5 296 282 266 249 233 215 197 180 164 131 98 65 32
PK 20 2 329 312 295 279 262 246 229 213 197 164 131 98 65 32

DIMENSIONS AND WEIGHT


f
i
DN2
h2
h3

h
DN1

h1

s n1
a w m n

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN1 DN2 a f h h1 h2 h3 i m n n1 w s 1~ 3~
PK 03 PK 03 1" 1" 1.7 9.5 5.9 2.4 2.9 5.4 0.7 3.1 4.7 3.9 2.1 0.2 11.7 11.7
PK 05 PK 05 1" 1" 1.9 10,15/9,84 5.9 2.4 3.1 5.6 0.7 3.1 4.7 3.9 2.1 0.2 17.0 14.1
PKH 05 PKH 05 1" 1" 2.2 11.2 7.0 2.8 3.3 6.1 0.7 3.5 5.4 4.4 2.4 0.2 22.3 20.3
PK 07 PK 07 1" 1" 2.2 11.2 7.0 2.8 3.3 6.1 0.7 3.5 5.4 4.4 2.4 0.2 22.7 21.8
PKH 07 PKH 07 3/4" 3/4" 2.3 11.3 7.0 2.8 3.7 6.5 0.7 3.5 5.4 4.4 2.4 0.2 22.7 20.5
PK 10 PK 10 1" 1" 2.2 13.7 8.3 3.1 3.7 6.8 0.7 3.9 6.2 4.9 3.3 0.3 33.1 28.9
PK 15 PK 15 1" 1" 2.2 13.7 8.3 3.1 3.7 6.8 0.7 3.9 6.2 4.9 3.3 0.3 35.3 33.5
PK 20 1" 1" 2.2 13.7 8.3 3.1 3.7 6.8 0.7 3.9 6.2 4.9 3.3 0.3 39.7

3
PQ pumps with peripheral impeller
recommended for industrial uses

RANGE OF PERFORMANCE GUARANTEE 2 YEARS subject to our general terms of sale.


Flow rate up to 24 gpm
Head up to 328 ft CONSTRUCTION CHARACTERISTICS

LIMITS OF USE
• PUMP BODY: cast iron, with threaded ports.
• PUMP BODY: brass for PQHH 05
Manometric suction lift up to 26 ft • MOTOR BRACKET (patent nº 1289150): aluminium with brass
Liquid temperature up to + 194°F insert; reduces starting difficulties due to seizure of the impeller
Environment temperature up to + 104°F after long periods of inactivity.
• IMPELLER: brass, of the type with radial peripheral vanes.
CONSTRUCTION AND SAFETY STANDARDS • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
EN 60034-1 • MECHANICAL SEAL: ceramic - graphite - NBR.
IEC 34-1 • ELECTRIC MOTOR: the pumps are close-coupled to a carefully
CEI 2-3 matched PEDROLLO electric motor, quiet running, totally enclosed
fan cooled (TEFC), suitable for continuous duty.
PQ: single-phase 115 V or 230 V - 60 Hz with capacitor and
INSTALLATION AND USE thermal overload protector.
PQ: three-phase 230/460 V - 60 Hz.
They are recommended for pumping clean water without abrasive
particles and liquids that are chemically non aggressive to the materials
• INSULATION: class F. • PROTECTION: IP 44.

from which the pump is made.


• REGISTERED MODEL nº 72753

THE HYDRAULIC CHARACTERISTICS OF THESE PUMPS,


OPTIONS ON REQUEST
TOGETHER WITH THEIR COMPACTNESS, MAKE THEM SUITABLE
FOR USE IN THE industrial SECTOR. The pumps must be installed in ⇒ pump shaft in stainless steel EN 10088-3 - 1.4401 (AISI 316)
enclosed places, or at least protected against inclement weather. ⇒ special mechanical seal
⇒ protection IP 55
⇒ other voltages or frequency 50 Hz

4
CURVES AND PERFORMANCE DATA

Head H (meters)
H Head H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 1.2 2.7 4 5.2 6.6 8 9.3 10.2 13.2 15.8 18.5 21 23
HP
1 PH 3 PH FLOW RATE l/min 0 5 10 15 20 25 30 35 40 50 60 70 80 90
PQ 03 PQ 03 0.33 131 125 110 95 79 64 49 33 16
PQ 05 PQ 05 0.5 181 164 149 133 118 102 89 72 56 26
PQH 05 PQH 05 0.5 214 204 187 171 154 138 122 105 89 59
PQ 07 PQ 07 0.7 230 217 200 184 168 151 135 120 102 72
H Feet
PQH 07 PQH 07 0.7 296 269 233 197 161 125 89 56 16
PQ 10 PQ 10 1 279 263 246 230 214 197 181 164 148 115 82 49
PQ 15 PQ 15 1.5 296 283 266 250 233 215 197 181 164 131 99 66 33
PQ 20 2 329 312 279 263 246 230 214 197 164 131 99 66 33

MODEL FLOW RATE GPM 0 0.5 1 1.5 2 2.8 3 3.3 4 4.8


HP
1 PH 3 PH FLOW RATE l/min 0 2 4 6 8 10 12 14 16 18
PQHH 05 PQHH 05 0.5 296 263 233 207 177 148 122 92 62 33
H Feet
PQHH 05 - Bs PQHH 05-Bs 0.5 296 263 233 207 177 148 122 92 62 33

DIMENSIONS AND WEIGHT


f i
DN2
h2
DN1
h3

h
h1

s n1
a w m n

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN1 DN2 a f h h1 h2 h3 i m n n1 w s 1~ 3~
PQ 03 PQ 03 1" 1" 0.9 8.8 6.0 4.3 1.2 5.4 3.1 3.1 4.7 3.9 2.2 0.3 11.7 11.7
PQ 05 PQ 05 1" 1" 0.9 9.21/8.93 6.0 4.4 1.2 5.6 3.1 3.1 4.7 3.9 2.2 0.3 15.6 13.9
PQH 05 PQH 05 1" 1" 0.9 10.0 7.0 4.8 1.2 5.9 3.3 3.5 5.4 4.4 2.4 0.3 21.8 19.6
PQHH 05 PQHH 05 1/2” 1/2” 0.7 8.93/8.66 6.0 4.6 0.9 5.6 2.8 3.1 4.7 3.9 2.3 0.3 14.8 15.0
PQHH 05-Bs PQHH 05-Bs 1/2” 1/2” 0.9 8.93/8.66 7.0 5.0 1.1 6.0 3.3 3.5 5.4 4.4 2.4 0.3 15.0 15.0
PQ 07 PQ 07 1" 1" 0.9 10.0 7.0 4.8 1.2 5.9 3.3 3.5 5.4 4.4 2.4 0.3 22.1 19.4
PQH 07 PQH 07 3/4” 3/4” 0.7 10.0 7.0 5.0 1.1 6.0 3.3 3.5 5.4 4.4 2.4 0.3 22.1 19.8
PQ 10 PQ 10 1" 1" 1.0 12.5 8.3 5.5 1.2 6.7 3.5 3.9 6.2 4.9 3.3 0.4 32.7 31.6
PQ 15 PQ 15 1" 1" 1.0 12.5 8.3 5.5 1.2 6.7 3.5 3.9 6.2 4.9 3.3 0.4 34.7 32.7
PQ 20 1" 1" 1.0 12.5 8.3 5.5 1.2 6.7 3.5 3.9 6.2 4.9 3.3 0.4 34.7

5
PQH 20 pump with peripheral impeller
for industrial uses

RANGE OF PERFORMANCE GUARANTEE 2 YEARS subject to our general terms of use


Flow rate up to 13 gpm
Head up to 590 ft CONSTRUCTION CHARACTERISTICS

LIMITS OF USE
• PUMP BODY: cast iron, with threaded ports.
• BODY BACK-PLATE: brass with front shim disk in stainless steel.
Manometric suction lift up to 26 ft • MOTOR BRACKET (patent nº 1289150): aluminium with brass
Liquid temperature up to + 194°F and stainless steel insert; eliminates seizure of the impeller after
Environment temperature up to + 104°F long periods of inactivity.
• IMPELLER: bronze, of the type with radial peripheral vanes.
CONSTRUCTION AND SAFETY STANDARDS • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
EN 60034-1 • MECHANICAL SEAL: ceramic - graphite - NBR.
IEC 34-1 • ELECTRIC MOTOR: the pumps are close-coupled to a carefully
matched PEDROLLO electric motor, quiet running, totally enclosed
CEI 2-3
fan cooled (TEFC), suitable for continuous duty.
PQH 20: three-phase 230V - 60 Hz.
INSTALLATION AND USE • INSULATION: class H. • PROTECTION: IP 55.

It is recommended for pumping clean water without abrasive particles OPTIONS ON REQUEST
and liquids that are chemically non aggressive to the materials from ⇒ pump shaft in stainless steel EN 10088-3 - 1.4401 (AISI 316)
which the pump is made. THE HYDRAULIC CHARACTERISTICS OF ⇒ special mechanical seal
THIS PUMP, TOGETHER WITH ITS COMPACTNESS AND ⇒ other voltages or frequency 50 Hz
STURDINESS, MAKE IT SUITABLE FOR USE IN THE industrial
SECTOR. The pump must be installed in enclosed places, or at least
protected against inclement weather.

6
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 2.7 4 5.2 6.6 8 9.3 10.2 11.9 13.2
HP
3 PH FLOW RATE l/min 0 10 15 20 25 30 35 40 45 50
PQH 20 2 H feet 590 525 476 433 387 344 302 256 208 164

DIMENSIONS AND WEIGHT

f
i

DN2
h2

DN1

h
h3
h1

s
a w m n1
n

MODEL SUCTION / DISCH DIMENSIONS INCHES LBS


3 PH DN1 DN2 a f h h1 h2 h3 i m n n1 w s 3~
PQH 20 3/4" 3/4" 1.3 12.9 8.3 5.5 1.4 7.0 2.5 3.9 6.5 4.9 3.8 0.3 42.0

7
PQA pumps with peripheral impeller
recommended for industrial applications

RANGE OF PERFORMANCE GUARANTEE 2 YEARS subject to our general terms of sale.


Flow rate up to 13 gpm
Head up to 295 ft CONSTRUCTION CHARACTERISTICS

LIMITS OF USE
• PUMP BODY: high-performance technopolymer with metal
threaded port insert for secure pipe connection without damage to
Manometric suction lift up to 26 ft the pump body.
Liquid temperature up to + 194°F • BODY BACK-PLATE: brass.
Environment temperature up to + 104°F • MOTOR BRACKET (patent nº 1289150): aluminium with brass
insert; eliminates seizure of the impeller after long periods of
CONSTRUCTION AND SAFETY STANDARDS inactivity.
EN 60034-1 • IMPELLER: brass, of the type with radial peripheral vanes.
IEC 34-1 • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
CEI 2-3 • MECHANICAL SEAL: ceramic - graphite - NBR.
• ELECTRIC MOTOR: the pumps are close-coupled to a carefully
matched PEDROLLO electric motor, quiet running, totally enclosed
INSTALLATION AND USE fan cooled (TEFC), suitable for continuous duty.
PQA: single-phase 115 V or 230 V - 60 Hz with capacitor and
They are recommended for pumping clean water without abrasive
thermal overload protector.
particles and liquids that are chemically non aggressive to the materials
PQA: three-phase 230/460 V - 60 Hz.
from which the pump is made. NON-FERROUS CONSTRUCTION WITH
WETTED PARTS IN HIGH PERFORMANCE TECHNOPOLYMER AND
• INSULATION: class F. • PROTECTION: IP 44.

BRASS TO ELIMINATE THE POSSIBILITY OF CORROSION.


• REGISTERED MODEL

CONSEQUENTLY THEY ARE RECOMMENDED FOR INDUSTRIAL


OPTIONS ON REQUEST
APPLICATIONS INCLUDING COOLING, CONDITIONING AND
BOILER FEED. ⇒ pump shaft in stainless steel EN 10088-3 - 1.4401 (AISI 316)
The pumps must be installed in enclosed places, or at least protected ⇒ special mechanical seal
against inclement weather. ⇒ protection IP 55
⇒ other voltages or frequency 50 Hz

8
CURVES AND PERFORMANCE DATA

Head H (meters)
H Head H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 0.5 1.2 2.7 4 5.2 6.6 8 8.5 10 12 13
HP
1 PH 3 PH FLOW RATE l/min 0 2 5 10 15 20 25 30 32 38 45 50
PQA 03 PQA 03 0.33 131 125 115 95 77 59 41 23 16
PQA 05 PQA 05 0.5 214 204 191 171 149 130 108 89 79 54 26
PQAH 05 PQAH 05 0.5 214 204 187 171 154 138 123 117 97 74 59
H Feet
PQA 07 PQA 07 0.7 230 217 204 184 163 141 122 102 92 67 39
PQAH 07 PQAH 07 0.7 230 217 200 184 168 151 136 130 123 87 72
PQAHH 07 PQAHH 07 0.7 296 283 260 223 186 149 112 76 61 16

DIMENSIONS AND WEIGHT

f
i
DN2
h2
DN1

h
h3
h1

s n1
a w m n

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN1 DN2 a f h h1 h2 h3 i m n n1 w s 1~ 3~
PQA 03 PQA 03 1/2" 1/2" 1.0 8.9 6.0 4.1 1.3 5.4 2.9 3.1 4.7 3.9 2.2 0.3 10.6 10.6
PQA 05 PQA 05 1/2" 1/2" 1.1 10.2 7.0 4.6 1.3 5.9 2.9 3.5 5.4 4.4 2.4 0.3 22.7 20.5
PQAH 05 PQAH 05 1" 1" 1.1 10.2 7.0 4.8 1.2 5.9 3.3 3.5 5.4 4.4 2.4 0.3 22.9 20.7
PQA 07 PQA 07 1/2" 1/2" 1.1 10.2 7.0 4.6 1.3 5.9 2.9 3.5 5.4 4.4 2.4 0.3 23.2 21.0
PQAH 07 PQAH 07 1" 1" 1.1 10.2 7.0 4.8 1.2 5.9 3.3 3.5 5.4 4.4 2.4 0.3 23.2 21.0
PQAHH 07 PQAHH 07 1/2" 1/2" 1.1 10.1 7.0 4.8 1.4 6.1 3.0 3.5 5.4 4.4 2.4 0.3 23.2 21.0

9
CP centrifugal pumps

RANGE OF PERFORMANCE GUARANTEE 2 YEARS subject to our general terms of use


Flow rate up to 42 gpm
Head up to 190 ft CONSTRUCTION CHARACTERISTICS

LIMITS OF USE
• PUMP BODY: cast iron, with threaded ports.
• BODY BACK-PLATE: stainless steel AISI 304 or cast iron on
Manometric suction lift up to 23 ft higher powered models.
Liquid temperature up to + 194°F • BRASS IMPELLER
Liquid temperature up to + 104°F in the CPX version • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
(with technopolymer impeller) • MECHANICAL SEAL: ceramic - graphite - NBR.
Environment temperature up to + 104°F • ELECTRIC MOTOR: the pumps are close-coupled to a carefully
matched PEDROLLO electric motor, quiet running, totally enclosed
CONSTRUCTION AND SAFETY STANDARDS fan cooled (TEFC), suitable for continuous duty.
EN 60034-1 CP: single-phase 115 V or 230 V - 60 Hz with capacitor and
IEC 34-1 thermal overload protector built into the winding.
CEI 2-3 CP: three-phase 230/460 V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 44.
• REGISTERED MODEL nº 72753.
INSTALLATION AND USE
OPTIONS ON REQUEST
They are recommended for pumping clean water and liquids that are
chemically non aggressive to the materials from which the pump is made. ⇒ impeller in technopolymer (CP...X - CP...X)
RELIABLE AND MAINTENANCE FREE THEY ARE WIDELY USED IN ⇒ special mechanical seal
THE DOMESTIC AND CIVIL SECTOR, IN PARTICULAR FOR WATER ⇒ other voltages or frequency 50 Hz
DISTRIBUTION IN COMBINATION WITH SMALL OR MEDIUM
PRESSURE SETS, FOR TRANSFER IN GENERAL, FOR IRRIGATING
GARDENS.
The pumps must be installed in enclosed places, or at least protected
against inclement weather.

10
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 2 5 7 10 13 15 18 21 23 26 29 31 34 37 39 42


HP
1 PH 3 PH FLOW RATE l/min 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160
CP 05 CP 05 0.5 99 94 89 84 77 69 57 46
CP 07 CP 07 0.7 115 112 108 103 97 89 79 67 56 43
CPH 10 CPH 10 1 138 135 130 126 122 118 113 108 102 95 85 76 61
CPH 15 CPH 15 1.5 158 154 151 148 145 141 138 133 128 120 112 102 89 76
H Feet
CPH 20 CPH 20 2 187 186 182 181 177 174 169 164 158 151 141 133 123 112 99
CP 10 CP 10 1 128 126 125 122 120 118 115 112 108 105 99 94 87 80 74 66 59
CP 15 CP 15 1.5 141 140 138 135 133 131 128 123 120 115 112 107 102 95 89 82 76
CP 20 CP 20 2.0 168 166 165 164 163 159 156 153 148 145 140 135 130 123 118 112 105

DIMENSIONS AND WEIGHT

f n
a
DN2
h2
h
DN1

h1

w s
n1

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN1 DN2 a f h h1 n n1 w s s 1~ 3~
CP 05 CP 05 1" 1" 1.3 9.7 7.4 3.0 5.8 4.6 1.8 0.4 0.4 15.0 15.2
CP 07 CP 07 1" 1" 1.7 10.5 8.3 3.2 6.5 5.3 1.6 0.4 0.4 18.6 0.0
CPH 10 CPH 10 1 1/4" 1" 1.7 11.7 9.5 3.8 7.5 6.3 1.7 0.4 0.4 26.7 25.6
CPH 15 CPH 15 1 1/4" 1" 2.0 13.4 10.2 4.3 8.1 6.5 1.7 0.4 0.4 42.4 40.9
CPH 20 CPH 20 1 1/4" 1" 2.0 13.4 10.2 4.3 8.1 6.5 1.7 0.4 0.4 55.3 53.5
CP 10 CP 10 1 1/4" 1" 2.0 13.4 10.2 4.3 8.1 6.5 1.7 0.4 0.4 58.1 56.4
CP 15 CP 15 1 1/4" 1" 2.0 13.4 10.2 4.3 8.1 6.5 1.7 0.4 0.4 42.4 40.9
CP 20 CP 20 1 1/4" 1" 2.0 13.4 10.2 4.3 8.1 6.5 1.7 0.4 0.4 55.3 53.5

11
CP close-coupled centrifugal pumps with threaded ports

Electric pumps with


high efficiency motor
for reduced energy
consumption

RANGE OF PERFORMANCE GUARANTEE 2 YEARS subject to our general terms of use


Flow rate up to 240 gpm
Head up to 246 ft CONSTRUCTION CHARACTERISTICS

LIMITS OF USE
• PUMP BODY: cast iron, with threaded ports.
• BODY BACK-PLATE: cast iron.
Manometric suction lift up to 23 ft • IMPELLER: brass for pumps up to 12.5 HP.
Liquid temperature up to + 195°F • IMPELLER: cast iron for pumps from 15 to 25 HP.
Environment temperature up to + 104°F • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• MECHANICAL SEAL: ceramic - graphite - NBR.
CONSTRUCTION AND SAFETY STANDARDS • ELECTRIC MOTOR: the pumps are close-coupled to a carefully
EN 60034-1 matched PEDROLLO electric motor, with high efficiency (class
IEC 34-1 “EFF1”), quiet running, totally enclosed fan cooled (TEFC), suitable
CEI 2-3 for continuous duty.
CP: three-phase 230/460 V - 60 Hz
• INSULATION: class F. • PROTECTION IP 44.
INSTALLATION AND USE • REGISTERED MODEL nº 72753

They are recommended for pumping clean water and liquids that are
• PATENTED ELECTRIC MOTOR

chemically non aggressive to the materials from which the pump is made.
OPTIONS ON REQUEST
RELIABLE AND MAINTENANCE FREE THEY ARE WIDELY USED IN
THE CIVIL, AGRICULTURAL AND INDUSTRIAL SECTORs, FOR ⇒ pump shaft in stainless steel EN 10088-3 - 1.4401 (AISI 316)
SUPPLYING WATER, FOR CONDITIONING OR COOLING SYSTEMS, ⇒ special mechanical seal
FOR IRRIGATION, ETC. ⇒ protection IP 55
The pumps must be installed in enclosed places, or at least protected ⇒ other voltages or frequency 50 Hz
against inclement weather.

12
GENERAL PERFORMANCE DATA

Head H (meters)
HHead H (feet)

Q
Flow Rate Q

13
CURVES AND PERFORMANCE DATA

H (meters)
H (feet)
Head H

Head H
H (meters)
H (feet)
SH

SH
PS
NP

PS
N

NP
N
P22 (HP)
Absorbed Power P

P22 (kW)
P

Q
Flow Rate Q

MODEL FLOW RATE GPM 0 13 26 39 52 66 79 92 105 119 132 145 158


HP
1 PH 3 PH FLOW RATE l/min 0 50 100 150 200 250 300 350 400 450 500 550 600
CPH 50 CPH 50 5 171 169 168 167 165 161 156 148 141 131
CPH 75 7.5 H Feet 197 197 197 195 196 192 187 181 172 166
CPH 100 10 246 246 245 244 243 241 238 233 225 221 214 206 197

14
CURVES AND PERFORMANCE DATA

H (meters)
H (feet)
Head H

Head H
H (meters)
H (feet)
SH

SH
PS
NP

PS
N

NP
N
P22 (HP)
Absorbed Power P

P22 (kW)
P
Q
Flow Rate Q

MODEL FLOW RATE GPM 0.0 26 52 79 105 132 158 185 211 238
HP
3 PH FLOW RATE l/min 0 100 200 300 400 500 600 700 800 900
CP 75 7.5 168 164 195 158 151 143 131 119 105 90
CP 100 10 H Feet 186 184 182 177 171 161 149 135 118 100
CP 125 12.5 204 204 202 197 189 179 166 149 130 109

15
CURVES AND PERFORMANCE DATA

H (meters)
H (feet)
Head H

Head H
H (meters)
H (feet)
SH

SH
PS
NP

PS
N

NP
N
P22 (HP)
Absorbed Power P

P22 (kW)
P

MODEL FLOW RATE GPM 0 26 52 79 105 132 158 185 211 238
HP
3 PH FLOW RATE l/min 0 100 200 300 400 500 600 700 800 900
CP-CPR 150 15 263 263 263 243 227 210 191 171 148 122
CP-CPR 200 20 H Feet 312 312 312 292 276 260 240 220 197 171
CP-CPR 250 25 361 361 361 342 325 309 289 269 246 220

16
DIMENSIONS AND WEIGHT

f
a n

DN2

h2

h
DN1

h1
s
n1
w n2

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN1 DN2 a f h h1 h2 n n1 n2 w s 3~
CPH 50 2" 2" 2.8 19.9 12.9 5.4 7.6 10.7 7.5 9.8 1.6 0.6 105.2
CPH 50 2" 2" 2.8 18.1 12.9 5.4 7.6 10.7 7.5 9.8 1.6 0.6 94.1
CPH 75 2" 2" 2.8 19.9 12.9 5.4 7.6 10.7 7.5 9.8 1.6 0.6 105.2
CPH 100 2" 2" 2.8 19.9 12.9 5.4 7.6 10.7 7.5 9.8 1.6 0.6 114.9
CP 75 2" 2" 2.8 19.9 12.9 5.4 7.6 10.7 7.5 9.8 1.6 0.6 105.2
CP 100 2" 2" 2.8 19.9 12.9 5.4 7.6 10.7 7.5 9.8 1.6 0.6 114.9
CP 125 2" 2" 2.8 19.9 12.9 5.4 7.6 10.7 7.5 9.8 1.6 0.6 116.0
CP 150 2" 2" 2.6 23.5 15.4 6.3 9.1 12.7 9.1 11.6 1.8 0.6 227.6
CP 200 2" 2" 2.6 27.3 15.4 6.3 9.1 12.7 9.1 11.6 1.8 0.6 265.2
CP 250 2" 2" 2.6 27.3 15.4 6.3 9.1 12.7 9.1 11.6 1.8 0.6 293.9
CPR 150 4" 3" 3.6 23.5 15.4 6.3 9.1 12.7 9.1 11.6 1.8 0.6 236.5
CPR 200 4" 3" 3.6 27.3 15.4 6.3 9.1 12.7 9.1 11.6 1.8 0.6 274.0
CPR 250 4" 3" 3.6 27.3 15.4 6.3 9.1 12.7 9.1 11.6 1.8 0.6 302.8

17
AR stainless steel centrifugal pump

RANGE OF PERFORMANCE GUARANTEE 2 YEARS subject to our general terms of sale.


Maximum flow rate 47 gpm
Maximum head 105 ft CONSTRUCTION CHARACTERISTICS

LIMITS OF USE
• PUMP BODY: stainless steel AISI 304, with threaded ports.
• BODY BACK-PLATE AND DIFFUSER: AISI 304.
Manometric suction lift up to 23 ft • IMPELLER: stainless steel AISI 304, of the type with centrifugal
Liquid temperature up to + 195°F radial flow.
Environment temperature up to + 130°F • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• MECHANICAL SEAL: ceramic - graphite - NBR.
CONSTRUCTION AND SAFETY STANDARDS • ELECTRIC MOTOR: the pumps are close-coupled to a carefully
EN 60034-1 matched PEDROLLO electric motor, quiet running, totally enclosed
IEC 34-1 fan cooled (TEFC), suitable for continuous duty.
CEI 2-3 AR 10: single-phase 115 V or 230 V - 60 Hz with capacitor
and thermal overload protector.
AR 10: three-phase 230/460 V - 60 Hz.
INSTALLATION AND USE • INSULATION : class F. • PROTECTION: IP 44.

It is recommended for pumping clean water and liquids that are


• REGISTERED MODEL nº 72753.

chemically non aggressive to the materials from which the pump is made.
OPTIONS ON REQUEST
THE CONSTRUCTION OF THESE CENTRIFUGAL PUMPS MAKES
THEM SUITABLE FOR USE IN THE DOMESTIC, AGRICULTURAL ⇒ version in stainless steel EN 10088-3 - 1.4401 (AISI 316)
AND INDUSTRIAL SECTOR. ALL THE WETTED PARTS ARE IN ⇒ special mechanical seal
STAINLESS STEEL AISI 340 TO GUARANTEE TOTAL HYGIENE ⇒ other voltages or frequency 50 Hz
AND MAXIMUM RESISTANCE TO CORROSION.
The pump must be installed in enclosed places, or at least protected
against inclement weather.

18
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 5 7 10 13 15 18 21 23 26 29 31 34 37 39 42 45 47


HP
1 PH 3 PH FLOW RATE l/min 0 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180
AR 10 AR 10 1.0 H Feet 105 102 101 100 99 97 95 92 90 87 83 80 76 72 68 63 58 53

DIMENSIONS AND WEIGHT

f
n
a
DN2
h2
h3
DN1

n1
h1

s
w n1

MODEL SUCTION /DISCH DIMENSIONS INCHES WEIGHT


1 PH 3 PH DN1 DN2 a f h h1 h2 h3 n n1 w s LBS
AR 10 AR 10 1 1/4" 1" 1.2 11.6 8.1 3.8 4.1 7.9 7.2 4.5 3.7 0.4 20.1

19
PNGA stainless steel pumps

Centrifugal pumps made


of stainless steel AISI
316, equipped with an
open impeller, ideal for
transferring liquids
containing impurities.

RANGE OF PERFORMANCE GUARANTEE 2 YEARS subject to our general terms of sale.


Flow rate up to 92 gpm
Head up to 66 ft CONSTRUCTION CHARACTERISTICS

LIMITS OF USE
• PUMP BODY: stainless steel AISI 316, with threaded ports.
• BODY BACK-PLATE: stainless steel AISI 316.
Manometric suction lift up to 23 ft • OPEN IMPELLER: stainless steel AISI 316.
Liquid temperature up to + 194°F • MOTOR SHAFT: stainless steel AISI 316.
Environment temperature up to + 104°F • MECHANICAL SEAL: ceramic - graphite - viton - AISI 316
Passage of solid bodies Ø 4/10” • ELECTRIC MOTOR: the pumps are close-coupled to a carefully
matched PEDROLLO electric motor, quiet running, totally enclosed
CONSTRUCTION AND SAFETY STANDARDS fan cooled (TEFC), suitable for continuous duty.
EN 60034-1 PNGA: single-phase 115 V or 230 V - 60 Hz with capacitor
IEC 34-1 and thermal overload protector.
CEI 2-3 PNGA: three-phase 230/460 V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 44.

INSTALLATION AND USE OPTIONS ON REQUEST


They are recommended for pumping water and liquids that are ⇒ special mechanical seal
chemically non aggressive to the materials from which the pump is made. ⇒ other voltages or frequency 50 Hz
THE OPEN IMPELLER DESIGN ALLOWS THE PUMPING OF ⇒ protection IP 55
LIQUIDS WITH RELATIVELY HIGH LEVELS OF IMPURITIES
WITHOUT RISK OF CLOGGING THE IMPELLER. FOR THIS REASON
THE PRO-NGA SERIES ARE SUITABLE FOR USE IN SYSTEMS FOR
WASHING FRUIT, VEGETABLES, FISH, SHELLFISH, MEAT, IN
INDUSTRIAL SYSTEMS FOR WASHING METAL PARTS, GLASS
CONTAINERS, AND FOR THE CIRCULATION OF COOLING LIQUIDS.
The pumps must be installed in enclosed places, or at least protected
against inclement weather.

20
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 13 26 39 52 66 79 86 92


HP
1 PH 3 PH FLOW RATE l/min 0 50 100 150 200 250 300 325 350
PNGA 05 PNGA 05 0.5 59 56 53 48 43 34 26 20
H Feet
PNGA 07 PNGA 07 0.7 66 64 59 54 49 41 33 26 20

DIMENSIONS AND WEIGHT

f
n
a
DN2
h2
h
DN1

h1

s
w n1

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN1 DN2 a f h h1 h2 n n1 w s 1~ 3~
PNGA 05 PNGA 05 1 1/2" 1 1/2" 1.6 11.7 8.9 3.6 5.3 7.5 6.3 2.0 0.4 28.7 26.5
PNGA 07 PNGA 07 1 1/2" 1 1/2" 1.6 11.7 8.9 3.6 5.3 7.5 6.3 2.0 0.4 29.0 26.7

21
3-4CP multi-stage centrifugal pumps

Particularly quiet
running with high
efficiency and low
power consumption.
Suitable for domestic
applications.

RANGE OF PERFORMANCE GUARANTEE 2 YEARS subject to our general terms of sale.


Flow rate up to 34 gpm
Head up to 164 ft CONSTRUCTION CHARACTERISTICS

LIMITS OF USE
• PUMP BODY: cast iron, with threaded ports.
• BODY BACK-PLATE: stainless steel AISI 304.
Manometric suction lift up to 23 ft • IMPELLERS: of the type with centrifugal radial flow, made of
Liquid temperature up to + 104°F technopolymer (approved for drinking water).
Environment temperature up to+ 104°F • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104
• MECHANICAL SEAL: ceramic - graphite - NBR.
CONSTRUCTION AND SAFETY STANDARDS • ELECTRIC MOTOR: the pumps are close-coupled to a carefully
EN 60 335-1 EN 60034-1 matched PEDROLLO electric motor, quiet running, totally enclosed
IEC 335-1 IEC 34-1 fan cooled (TEFC), suitable for continuous duty.
CEI 61-150 CEI 2-3 3-4CP: single-phase 115 V or 230 V - 60 Hz with capacitor
and thermal overload protector.
3-4CP: three-phase 230/460 V - 60 Hz.
INSTALLATION AND USE • INSULATION: class F. • PROTECTION: IP 44.

They are recommended for pumping clean water and liquids that are
• REGISTERED MODEL

chemically non aggressive to the materials from which the pump is made. OPTIONS ON REQUEST
DUE TO THEIR RELIABILITY, QUIET RUNNING AND LOW
⇒ other voltages or frequency 50 Hz
MAINTENANCE, THEY ARE SUITABLE FOR DOMESTIC
APPLICATIONS INCLUDING WATER SUPPLIES (AS A PRESSURE
SET), GARDEN IRRIGATION, ETC.
The pumps must be installed in enclosed places, or at least protected
against inclement weather.

22
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 1 2 3 5 6 7 10 13 15 18 21 23 26 29 31 34


HP
1 PH 3 PH FLOW RATE l/min 0 5 10 15 20 25 30 40 50 60 70 80 90 100 110 120 130
3CP 04 3CP 04 0.4 125 118 115 112 110 102 95 82 66 51 33 16
4CP 05 4CP 05 0.5 164 158 154 148 141 133 126 110 92 74 53 33
H Feet
3CP 05 3CP 05 0.5 118 117 115 112 110 107 105 99 92 85 76 66 56 44 33 16
4CP 07 4CP 07 0.7 151 148 145 141 138 135 131 125 117 108 99 87 74 62 49 33 16

DIMENSIONS AND WEIGHT

f n
a
DN2
h2
DN1

h
h1

w s
n1

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN1 DN2 a f h h1 h2 n n1 w s 1~ 3~
3CP 04 3CP 04 1" 1" 4.3 13.1 6.8 5.3 1.5 6.2 4.6 0.1 0.4 19 19
4CP 05 4CP 05 1" 1" 5.3 14.5 / 14.2 6.8 5.3 1.5 6.2 4.6 0.1 0.4 20.8 19.7
3CP 05 3CP 05 1" 1" 4.3 13.5 / 13.2 6.8 5.3 1.5 6.2 4.6 0.1 0.4 23.9 22.5
4CP 07 4CP 07 1" 1" 5.3 14.9 7.5 5.3 2.4 6.2 4.6 0.1 0.4 22.5 20.8

23
3-4CR multi-stage centrifugal pumps
stainless steel pump body

Particularly quiet
running with high
efficiency and low
power consumption.
Suitable for domestic
applications.

RANGE OF PERFORMANCE GUARANTEE 2 YEARS subject to our general terms of sale.


Flow rate up to 31 gpm
Head up to 164 ft CONSTRUCTION CHARACTERISTICS

LIMITS OF USE
• PUMP BODY: stainless steel AISI 304, with threaded ports.
• BODY BACK-PLATE: stainless steel AISI 304.
Manometric suction lift up to 23 ft • IMPELLERS: of the type with centrifugal radial flow, made of
Liquid temperature up to + 104°F technopolymer (approved for drinking water).
Environment temperature up to + 104°F • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• MECHANICAL SEAL: ceramic - graphite - NBR.
CONSTRUCTION AND SAFETY STANDARDS • ELECTRIC MOTOR: the pumps are close-coupled to a carefully
EN 60 335-1 EN 60034-1 matched PEDROLLO electric motor, quiet running, totally enclosed
IEC 335-1 IEC 34-1 fan cooled (TEFC), suitable for continuous duty.
CEI 61-150 CEI 2-3 3-4CR: single-phase 115 V or 230 V - 60 Hz with capacitor and
thermal overload protector.
3-4CR: three-phase 230/460 V - 60 Hz.
INSTALLATION AND USE • INSULATION: class F. • PROTECTION: IP 44

They are recommended for pumping clean water and liquids that are .
OPTIONS ON REQUEST
chemically non aggressive to the materials from which the pump is made.
DUE TO THEIR RELIABILITY AND QUIET RUNNING, THEY ARE ⇒ special mechanical seal
SUITABLE FOR RESIDENTIAL APPLICATIONS INCLUDING ⇒ other voltages or frequency 50 Hz
WATER SUPPLIES (AS A PRESSURE SET), GARDEN
IRRIGATION, ETC.
The pumps must be installed in enclosed places, or at least protected
against inclement weather.

24
CURVES AND PERFORMANCE DATA

Head H (meters)
Head H (feet)

Flow Rate Q

MODEL FLOW RATE GPM 0 1 2 3 5 6 7 10 13 15 18 21 23 26 29 31


HP
1 PH 3 PH FLOW RATE l/min 0 5 10 15 20 25 30 40 50 60 70 80 90 100 110 120
3CR 04 3CR 04 0.4 125 118 115 112 107 102 95 82 66 51 33 16
4CR 05 4CR 05 0.5 H Feet 164 158 154 148 141 133 126 110 110 92 74 53 33
3CR 05 3CR 05 0.5 118 117 115 112 110 107 105 99 92 84 76 66 56 44 33 16

DIMENSIONS AND WEIGHT

f n
a
DN2
h2
DN1
h
h1

w s
n1

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN1 DN2 a f h h1 h2 n n1 w s 1~ 3~
3CR 04 3CR 04 1" 1" 3.5 13.6 6.9 4.8 2.0 6.3 4.7 3.7 0.4 15.2 13.9
4CR 05 4CR 05 1" 1" 3.5 13.9 /13.6 6.9 4.8 2.0 6.3 4.7 3.7 0.4 16.8 15.2
3CR 05 3CR 05 1" 1" 3.5 13.9 /13.7 6.9 4.8 2.0 6.3 4.7 3.7 0.4 16.5 15.2

25
VL 18G vertical multi-stage pumps

Robust vertical multi-stage


pumps in stainless steel,
distinguished by their high
efficiency and particularly
quiet operation.

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 23 gpm
• OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304
Head up to 348 ft case with threaded ports.
LIMITS OF USE • IMPELLERS AND DIFFUSERS: technopolymer.
Manometric suction lift up to 23 ft • DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings.
Liquid temperature up to 104°f • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• DOUBLE SEAL: mechanical seal silicon carbide-NBR, with oil barrier
chamber and inner lip seal to protect the seal in the event of dry running.
CONSTRUCTION AND SAFETY STANDARDS • SCREWS: stainless steel AISI 304.
EN 60 335-1 EN 60034-1 • MOTOR: electric, asynchronous for continuous duty.
IEC 335-1 IEC 34-1 VL: single-phase 230V - 60 Hz with thermal overload protector
CEI 61-150 CEI 2-3 built into windings below 1.5 Hp. The 2 Hp motor has an
external (with manual reset) incorporated into the control box.
VL: three-phase 230V - 60 Hz.
INSTALLATION AND USE • INSULATION: class F. • PROTECTION: IP 68.
They are recommended for pumping clean water and liquids that are
chemically non aggressiveto to the materials from which the pump is made. STANDARD FEATURES:
THEIR RELIABILITY AND QUIET RUNNING MAKE THEM SUITABLE
VL
VL 1
18
8G
G (single-phase) 6 ft power cable type
FOR DOMESTIC AND CIVIL APPLICATIONS, BECAUSE THE PUMP
“H07 RN-F” with removable connector.
IS FULLY SUBMERSIBLE WITH THE MOTOR COOLED BY THE
Control box with capacitor
PUMPED LIQUID, IT CAN BE USED SAFELY IN WET
ENVIRONMENTS AND IN SPACES WITH INSUFFICIENT VL
VL 1
18
8G
G (three-phase) 6 ft power cable type
VENTILATION. “H07 RN-F” with removable connector.
GUARANTEE 2 YEARS subject to our general terms of sale.
OPTIONS ON REQUEST
⇒ other voltages or frequency 50 Hz

26
CURVES AND PERFORMANCE DATA

H (meters)
H (feet)
Head H

Head H
Flow Rate Q
Q

MODEL FLOW RATE GPM 0 2 5 7 10 11 13 14 15 17 18 19 21 22 23


HP
1 PH 3 PH FLOW RATE l/min 0 10 20 30 40 45 50 55 60 65 70 75 80 85 90
VL18G 15 1.5 283 276 269 256 243 237 230 220 210 200 191 177 164 151 138
VL18G 20 VL18G 20 2.0 H
H Feet 329 319 306 289 273 263 253 240 230 217 207 194 179 164 151
VL18GH 20 VL18GH 20 2.0 348 340 329 315 299 289 279 269 260 243 233 214 204 184 164

DIMENSIONS AND WEIGHT

a
DN2

SINGLE-PHASE CONTROL BOX

h2
h
c

b d
DN1

h1

s
w2 w2
w1 w1
n f

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS

1 PH 3 PH DN1 DN2 No STAGES a b c d f h (1~) h (3~) h (1) h2(1~) h2 (3~) n w1 w2 s 1~ 3~

VL18G15 4 22.5 20.1 50.8


23.7 21.3
VL18G20 VL18G20 1 1/2" 1 1/4" 3.9 3.1 7.8 2.6 8.7 23.7 2.3 21.3 7.2 2.4 3.4 0.4 53.3 49.5
5
VL18GH20 VL18GH20 26.6 23.7 24.3 21.3 65.9 53.3

27
VL 25G vertical multi-stage pumps

Robust vertical multi-


stage pumps in
stainless steel,
distinguished by their
high efficiency and
particularly quiet
operation.

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 34 gpm • OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304
Head up to 296 ft case with threaded ports.
• IMPELLERS AND DIFFUSERS: technopolymer.
LIMITS OF USE • DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings.
Manometric suction lift up to 23 ft • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
Liquid temperature up to 104°f • DOUBLE SEAL: mechanical seal silicon carbide-NBR, with oil barrier
chamber and inner lip seal to protect the seal in the event of dry running.
• SCREWS: stainless steel AISI 304.
CONSTRUCTION AND SAFETY STANDARDS • MOTOR: electric, asynchronous for continuous duty.
VL 25G: single-phase 230V - 60 Hz with thermal overload protector built
EN 60 335-1 EN 60034-1
into windings below 1.5 Hp. The 2 Hp motor has an external
IEC 335-1 IEC 34-1 overload protector (with manual reset) incorporated into the control box.
CEI 61-150 CEI 2-3 VL 25G: three-phase 230V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 68.

INSTALLATION AND USE


STANDARD FEATURES:
They are recommended for pumping clean water and liquids that
are chemically non aggressive to the materials from which the VL
VL 2
25
5G
G (single-phase ) 6 ft power cable type
“H07 RN-F” with removable connector.
pump is made.
Control box with capacitor.
THEIR RELIABILITY AND QUIET RUNNING MAKE THEM SUITABLE
FOR DOMESTIC AND CIVIL APPLICATIONS, BECAUSE THE PUMP VL
VL 2
25
5G
G (three-phase ) 6 ft power cable type
IS FULLY SUBMERSIBLE WITH THE MOTOR COOLED BY THE “H07 RN-F” with removable connector.
PUMPED LIQUID, IT CAN BE USED SAFELY IN WET
ENVIRONMENTS AND IN SPACES WITH INSUFFICIENT
VENTILATION.
OPTIONS ON REQUEST
GUARANTEE 2 YEARS subject to our general terms of sale. ⇒ other voltages or frequency 50 Hz

28
CURVES AND PERFORMANCE DATA

Head H (meters)
H Head H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 2 5 7 10 13 15 18 21 23 26 29 31 34


HP
1 PH 3 PH FLOW RATE l/min 0 10 20 30 40 50 60 70 80 90 100 110 120 130
VL25G 15 1.5 223 220 217 210 204 195 187 176 164 151 135 122 105 89
VL25G 20 VL 25G 20 2.0 H Feet 263 260 253 246 240 233 223 214 204 191 177 161 145 125
VL25GH 20 VL 25GH 20 2.0 296 292 289 283 276 269 263 253 246 237 223 210 195 177

DIMENSIONS AND WEIGHT

a
DN2

SINGLE-PHASE CONTROL BOX

h2
h
c

b d
DN1

h1

s
w1 w1 w2 w2
n f

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS

1 PH 3 PH DN1 DN2 No STAGES a b c d f h (1~) h (3~) h (1) h2 (1~) h2 (3~) n w1 w2 s 1~ 3~

VL25G15 4 22.5 20.1 50.8


23.7 21.3
VL25G 20 VL25G 20 1 1/2" 1 1/4" 5 125.4 106.4 225.4 91.4 248.4 23.7 2.3 21.3 7.2 2.4 3.4 0.4 53.3 49.5

VL25G H20 VL25G H20 4 25.5 22.5 23.1 20.1 63.9 51.3

29
VLE 18G
“in-line” multi-stage pumps

Compact multi-stage pumps, in


stainless steel, with suction and
delivery ports “in line”. They can be
installed in a horizontal or vertical
position, or completely submerged. The
enclosed design also eliminates any
possibility of water escaping.

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Maximum flow rate 23 gpm • OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304
Head up to 348 ft case with threaded ports.

LIMITS OF USE
• IMPELLERS AND DIFFUSORS: technopolymer.
• DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings.
Manometric suction lift up to 23 ft • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
Liquid temperature up to 104°f • DOUBLE SEAL: mechanical seal silicon carbide-NBR, with oil barrier chamber
and inner lip seal to protect the seal in the event of dry running.
• SCREWS: stainless steel AISI 304.
CONSTRUCTION AND SAFETY STANDARDS • MOTOR: electric, asynchronous for continuous duty.
EN 60 335-1 EN 60034-1 VLE: single-phase 230V - 60 Hz with thermal overload protector built
IEC 335-1 IEC 34-1 into windings below 1.5 Hp. The 2 Hp motor has an external
CEI 61-150 CEI 2-3 overload protector (with manual reset) incorporated into the control box.
VLE: three-phase 230V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 68.
INSTALLATION AND USE
STANDARD FEATURES:
They are recommended for pumping clean water and liquids that are
chemically non aggressive to the materials from which the pump is made.
VL
VLEE 1
188G
G (single-phase) 6 ft power cable type
THEIR RELIABILITY AND QUIET RUNNING MAKE THEM SUITABLE
FOR DOMESTIC AND CIVIL APPLICATIONS AND, BECAUSE THE “H07 RN-F” with removable connector.
PUMP IS FULLY SUBMERSIBLE WITH THE MOTOR COOLED BY Control box with capacitor.
THE PUMPED LIQUID, IT CAN BE USED SAFELY IN WET AREAS
VL
VLEE 1
188G
G (three-phase) 6 ft power cable type
AND IN SPACES WITH INSUFFICIENT VENTILATION. THE
ENCLOSED DESIGN ALSO ELIMINATES THE POSSIBILITY OF “H07 RN-F” with removable connector.
WATER ESCAPING AS A RESULT OF SEAL FAILURE, MAKING IT
SUITABLE FOR USE IN CARPETED OR OTHER DELICATE OPTIONS ON REQUEST

ENVIRONMENTS.
other voltages or frequency 50 Hz
GUARANTEE 2 YEARS subject to our general terms of sale.

30
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 2 5 7 10 11 13 14 15 17 18 19 21 22 23


HP
1 PH 3 PH FLOW RATE l/min 0 10 20 30 40 45 50 55 60 65 70 75 80 85 90
VLE18G 15 1.5 283 276 269 256 243 237 230 220 210 200 191 177 164 151 138
VLE18G 20 VLE18G 20 2.0 H Feet 329 319 306 289 273 263 253 240 230 217 207 194 179 164 151
VLE18GH 20 VLE18GH 20 2.0 348 340 329 315 299 289 279 269 260 243 233 214 204 184 164

DIMENSIONS AND WEIGHT

Vertical installation Horizontal installation


DN2

SINGLE-PHASE CONTROL BOX


h

h
b

DN2

a c
DN1

DN1
Ø

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS


No STAGES
1 PH 3 PH DN Ø h (1~) h (3~) a b c 1~ 3~
VLE18G 15 4 20.3 - 43.1 -
VLE18G 20 VLE18G 20 1 1/4" 6.0 21.5 21.5 3.1 7.8 2.5 45.5 41.8
5
VLE18G H20 VLE18G H20 24.4 21.5 58.1 45.5

31
VLE 25G
“in-line” multi-stage pumps

Compact multi-stage pumps in


stainless steel, with suction and
delivery ports “in line”. They can be
installed in a horizontal or vertical
position or when completely
submerged. The enclosed design
also eliminates any possibility of
water escaping.

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 34 gpm • OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304
Head up to 296 ft case with threaded ports

LIMITS OF USE
• IMPELLERS AND DIFFUSERS: technopolymer.
• DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings.
Manometric suction lift up to 25 ft • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
Liquid temperature up to 104°f • DOUBLE SEAL: mechanical seal silicon carbide-NBR, with oil barrier
chamber and inner lip seal to protect the seal in the event of dry running.

CONSTRUCTION AND SAFETY STANDARDS


• SCREWS: stainless steel AISI 304.
• MOTOR: electric, asynchronous for continuous duty.
EN 60 335-1 EN 60034-1 VLE 25G: single-phase 230V - 60 Hz with thermal overload protector built
into windings below 1.5 Hp. The 2 Hp motor has an external
IEC 335-1 IEC 34-1
overload protector (with manual reset) incorporated into the control box.
CEI 61-150 CEI 2-3
VLE 25G: three-phase 230V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 68.

INSTALLATION AND USE


STANDARD FEATURES:
They are recommended for pumping clean water and liquids that
are chemically non aggressive to the materials from which the VLE 25G (single-phase) 6 ft power cable type
pump is made. “H07 RN-F” with removable connector.
THEIR RELIABILITY AND QUIET RUNNING MAKE THEM SUITABLE Control box with capacitor
FOR DOMESTIC AND CIVIL APPLICATIONS AND, BECAUSE THE
PUMP IS FULLY SUBMERSIBLE WITH THE MOTOR COOLED BY VLE 25G (three-phase) 6 ft power cable type
THE PUMPED LIQUID, IT CAN BE USED SAFELY IN WET AREAS “H07 RN-F” with removable connector.
AND IN SPACES WITH INSUFFICIENT VENTILATION. THE
ENCLOSED DESIGN ALSO ELIMINATES THE POSSIBILITY OF
WATER ESCAPING AS A RESULT OF SEAL FAILURE, MAKING IT
OPTIONS ON REQUEST
SUITABLE FOR USE IN CARPETED OR OTHER DELICATE
ENVIRONMENTS. ⇒ other voltages or frequency 50 Hz

GUARANTEE 2 YEARS subject to our general terms of sale.

32
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 2 5 7 10 13 15 18 21 23 26 29 31 34


HP
1 PH 3 PH FLOW RATE l/min 0 10 20 30 40 50 60 70 80 90 100 110 120 130
VLE25G 15 1.5 223 220 217 210 204 195 187 176 164 151 135 122 105 89
VLE25G 20 VLE25G 20 2.0 H Feet 263 260 253 246 240 233 223 214 204 191 177 161 145 125
VLE25GH 20 VLE25GH 20 2.0 296 292 289 283 276 269 263 253 246 237 223 210 195 177

DIMENSIONS AND WEIGHT

Vertical installation Horizontal installation


DN2

SINGLE-PHASE CONTROL BOX


h

h
b

DN2

a c
DN1

DN1
Ø

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS


No STAGES
1 PH 3 PH DN Ø h 1~ h 3~ a b c 1~ 3~
VLE25G 15 4 20.3 43.1
21.5
VLE25G 20 VLE25G 20 1 1/4" 6.0 21.5 3.2 7.9 2.6 45.5 41.8
5
VLE25GH 20 VLE25GH 20 23.3 20.3 56.1 43.5

33
PKS self-priming pumps with peripheral impeller

RANGE OF PERFORMANCE GUARANTEE 2 YEARS subject to our general terms of sale.


Flow rate up to 13 gpm
Head up to 330 ft CONSTRUCTION CHARACTERISTICS

LIMITS OF USE
• PUMP BODY: cast iron, with threaded ports.
• CHECK FLAP VALVE: incorporated in the suction port.
Manometric suction lift up to 29 ft • MOTOR BRACKET (patent nº 1289150): aluminium with brass
Liquid temperature up to + 140°F insert; reduces starting difficulties due to seizure of the
Environment temperature up to + 104°F impeller after long periods of inactivity.
• IMPELLER: brass, of the type with radial peripheral vanes.
CONSTRUCTION AND SAFETY STANDARDS • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
EN 60034-1 • MECHANICAL SEAL: ceramic - graphite - NBR.
IEC 34-1 • ELECTRIC MOTOR: the pumps are close-coupled to a carefully
CEI 2-3 matched PEDROLLO electric motor, quiet running, totally enclosed
fan cooled (TEFC), suitable for continuous duty.
PKS: single-phase 115 V or 230 V - 60 Hz with capacitor and
INSTALLATION AND USE thermal overload protector.
PKS: three-phase 230/460 V - 60 Hz
They are recommended for pumping clean water without abrasive particles
and liquids that are chemically non aggressive to the materials from which
• INSULATION: class F. • PROTECTION: IP 44.
the pump is made.
• REGISTERED MODEL nº 72753.
FOR THEIR COMPACTNESS, RELIABILITY AND ECONOMY THEY
ARE SUITABLE FOR DOMESTIC USE AND IN PARTICULAR FOR OPTIONS ON REQUEST
DISTRIBUTING WATER IN COMBINATION WITH SMALL PRESSURE ⇒ special mechanical seal
SETS, FOR IRRIGATING GARDENS, DRAWING WATER FROM TANKS ⇒ other voltages or frequency 50 Hz
OR WELLS DOWN TO A DEPTH OF 27 FEET AND IN ALL CASES
WHERE THERE IS THE PRESENCE OF AIR OR GAS IN THE LIQUID TO
BE PUMPED; the pump is provided with a check flap valve on the intake so
that it is no longer necessary to fit a foot valve. The pumps must be installed
in enclosed places, or at least protected against inclement weather.

34
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 1.2 2.7 4 5.5 6.6 8 9.3 10.2 11.9 13.2
HP
1 PH 3 PH FLOW RATE l/min 0 5 10 15 20 25 30 35 40 45 50
PKS 03 PKS 03 0.33 131 125 110 95 79 64 49 33 16
PKS 05 PKS 05 0.5 180 164 149 133 118 102 89 72 56 41 26
H feet
PKSH 05 PKSH 05 0.5 213 203 187 171 154 138 121 105 89 72 59
PKS 07 PKS 07 0.7 230 216 200 184 167 151 134 120 102 89 72

DIMENSIONS AND WEIGHT

n
f
k
DN2 i
h2
DN1

h3
h1
h

s
a w m n1

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN1 DN2 a f h h1 h2 h3 i m n k n1 w S 1~ 3~
PKS 03 PKS 03 1" 1" 1.1 9.1 7.5 6.1 1.3 7.4 4.3 3.1 5.9 4.7 3.9 2.1 0.2 13.4 13.4
PKS 05 PKS 05 1" 1" 1.1 9.4/ 9.0 7.5 6.1 1.3 7.4 4.3 3.1 5.9 4.7 3.9 2.1 0.2 17.0 15.6
PKSH 05 PKSH 05 1" 1" 1.1 10.2 7.8 6.4 1.3 7.7 4.3 3.5 6.2 5.4 4.4 2.4 0.2 23.6 21.2
PKS 07 PKS 07 1" 1" 1.1 10.2 7.8 6.4 1.3 7.7 4.3 3.5 6.2 5.4 4.4 2.4 0.2 23.8 21.4

35
JSW “Shallow Well” self-priming jet pumps

RANGE OF PERFORMANCE GUARANTEE 2 YEARS subject to our general terms of sale.


Flow rate up to 13 gpm
Head up to 154 ft CONSTRUCTION CHARACTERISTICS

LIMITS OF USE
• PUMP BODY: cast iron, with threaded ports.
• BODY BACK-PLATE: stainless steel AISI 304.
Manometric suction lift up to 29 ft • EJECTOR ASSEMBLY: technopolymer (approved for drinking water).
Liquid temperature up to + 104°F • IMPELLER: technopolymer up to 1 HP.
Environment temperature up to + 104°F • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• MECHANICAL SEAL: ceramic - graphite -NBR.
CONSTRUCTION AND SAFETY STANDARDS • ELECTRIC MOTOR: the pumps are close-coupled to a carefully
matched PEDROLLO electric motor, quiet running, totally enclosed
EN 60 335-1 EN 60034-1
fan cooled (TEFC), suitable for continuous duty.
IEC 335-1 IEC 34-1
JSW: single-phase 115 V or 230 V - 60 Hz with capacitor and
CEI 61-150 CEI 2-3
thermal overload protector.
JSW: three-phase 230/460 V - 60 Hz.
INSTALLATION AND USE • INSULATION: class F. • PROTECTION: IP 44.

They are recommended for pumping clean water and liquids that are
• REGISTERED MODEL nº 72753.

chemically non aggressive to the materials from which the pump is made.
OPTIONS ON REQUEST
JSW SELF-PRIMING PUMPS ARE DESIGNED FOR SUCTION LIFTS
AND CAN BE POSITIONED ABOVE THE WATER SOURCE, ⇒ impeller in technopolymer (JSW...X - JSW...X)
INCLUDING APPLICATIONS WITH AIR ENTRAINED IN THE WATER. ⇒ other voltages or frequency 50 Hz
DUE TO THEIR RELIABILITY AND LOW MAINTENANCE, THEY
ARE RECOMMENDED FOR RESIDENTIAL USE, INCLUDING
WATER DISTRIBUTION (AS PART OF A PRESSURE SET), GARDEN
IRRIGATION, ETC.
The pumps must be installed in enclosed places, or at least protected
against inclement weather.

36
CURVES AND PERFORMANCE DATA

JSW 05 JSW 07

Discharge Pressure - PSI Discharge Pressure - PSI


Suction Lift Max Shut OFF Suction Lift Max Shut OFF
30 40 50 60 30 40 50 60
Depth (feet) PSI Depth (feet) PSI
Discharge Capacity US GPM Discharge Capacity US GPM
5 12 8 5 2 70 5 21 20 7 2 65
10 11 6.5 4 1.5 68 10 18.5 11 6.5 1,5 63
15 10.5 6.5 3.5 1 65.5 15 16.2 10 5.3 61
20 8.5 5.5 3 0.5 62.5 20 14.9 8 2.9 59
25 8 5 2.5 61.5 25 7.2 5.5 1.5 57

JSWH 07 JSW 10

Discharge Pressure - PSI Discharge Pressure - PSI


Suction Lift Max Shut OFF Suction Lift Max Shut OFF
30 40 50 60 30 40 50 60
Depth (feet) PSI Depth (feet) PSI
Discharge Capacity US GPM Discharge Capacity US GPM
5 14 13 8.5 6 80 5 22 21 15.8 10 79
10 13 12 8 5 78 10 22 21 14.5 8.5 77
15 12 11 7 4 76 15 21 20 12.6 7.2 75
20 10 9 6 3 74 20 20 18.5 10.5 5 73
25 9 7 5 2 72 25 20 18 10.3 4 71

JSWH 10 JSWQ 15

Discharge Pressure - PSI Discharge Pressure - PSI


Suction Lift Max Shut OFF Suction Lift Max Shut OFF
30 40 50 60 30 40 50 60
Depth (feet) PSI Depth (feet) PSI
Discharge Capacity US GPM Discharge Capacity US GPM
5 14 14 12 9 102 5 40 30 18 12 74
10 13.5 13.5 10 7.5 100 10 40 29 16.5 10.5 72
15 13 13 9.8 7 98 15 39.5 28.5 14.5 9 70
20 13 12.5 9 6.5 96 20 39.5 28.5 12 8.5 68
25 12 11 8 6 94 25 39.5 28.5 11.5 8 66

DIMENSIONS AND WEIGHT

f n
a
DN2
h2
DN1

h
h3
h1

s
w n1

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN1 DN2 a f h h1 h2 h3 n n1 w s 1~ 3~
JSW 05 JSW 05 1" 1" 4.5 15.2 / 14.9 6.7 5.0 1.3 6.3 6.3 4.9 0.4 0.4 22.1 22.5
JSW 07 JSW 07 1" 1" 4.5 15.8 7.9 5.8 1.4 7.2 7.1 5.6 0.9 0.4 30.3 30.5
JSWH 07 JSWH 07 1" 1" 4.5 15.8 7.9 5.8 1.4 7.2 7.1 5.6 0.9 0.4 30.3 30.5
JSW 10 JSW 10 1" 1" 4.5 15.8 7.9 5.8 1.4 7.2 7.1 5.6 0.9 0.4 33.2 30.5
JSWH 10 JSWH 10 1" 1" 4.5 15.8 7.9 5.8 1.4 7.2 7.1 5.6 0.9 0.4 33.2 30.9
JSWQ 15 JSWQ 15 1 1/4" 1" 4.5 15.8 7.9 5.8 1.4 7.2 7.1 5.6 0.9 0.4 59.0 57.0

37
JCR “Shallow Well” self-priming jet pumps
stainless steel pump body

RANGE OF PERFORMANCE GUARANTEE 2 YEARS subject to our general terms of sale.


Flow rate up to 21 gpm
Head up to 236 ft CONSTRUCTION CHARACTERISTICS

LIMITS OF USE
• PUMP BODY: stainless steel AISI 304, with threaded ports.
• BODY BACK-PLATE: stainless steel AISI 304.
Manometric suction lift up to 29 ft • EJECTOR ASSEMBLY: technopolymer (approved for drinking water).
Liquid temperature up to + 104°F • IMPELLER: technopolymer (for drinking water).
Environment temperature up to + 104°F • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104
• MECHANICAL SEAL: ceramic - graphite - NBR.
CONSTRUCTION AND SAFETY STANDARDS • ELECTRIC MOTOR: the pumps are close-coupled to a carefully
EN 60 335-1 EN 60034-1 matched PEDROLLO electric motor, quiet running, totally enclosed fan
IEC 335-1 IEC 34-1 cooled (TEFC), suitable for continuous dut..
CEI 61-150 CEI 2-3 JCR: single-phase 115 V or 230 V - 60 Hz with capacitor and
thermal overload protector.
JCR: three-phase 230/460 V - 60 Hz.
INSTALLATION AND USE • INSULATION: class F. • PROTECTION: IP 44.
They are recommended for pumping clean water and liquids that are
OPTIONS ON REQUEST
chemically non aggressive to the materials from which the pump is made.
JCR SELF-PRIMING PUMPS ARE DESIGNED FOR SUCTION LIFTS ⇒ other voltages or frequency 50 Hz
AND CAN BE POSITIONED ABOVE THE WATER SOURCE,
INCLUDING APPLICATIONS WITH AIR ENTRAINED IN THE WATER.
DUE TO THEIR RELIABILITY AND LOW MAINTENANCE, THEY ARE
RECOMMENDED FOR DOMESTIC USE, INCLUDING WATER
DISTRIBUTION (AS PART OF A PRESSURE SET), GARDEN
IRRIGATION, ETC.
The pumps must be installed in enclosed places, or at least protected
against inclement weather.

38
CURVES AND PERFORMANCE DATA

JCR 05 JCR 07

Discharge Pressure - PSI Discharge Pressure - PSI


Suction Lift Max Shut OFF Suction Lift Max Shut OFF
30 40 50 60 30 40 50 60
Depth (feet) PSI Depth (feet) PSI
Discharge Capacity US GPM Discharge Capacity US GPM
5 12 8 5 2 70 5 21 20 7 2 65
10 11 6.5 4 1.5 68 10 18.5 11 6.5 1,5 63
15 10.5 6.5 3.5 1 65.5 15 16.2 10 5.3 61
20 8.5 5.5 3 0.5 62.5 20 14.9 8 2.9 59
25 8 5 2.5 61.5 25 7.2 5.5 1.5 57

JCRH 07 JCR 10

Discharge Pressure - PSI Discharge Pressure - PSI


Suction Lift Max Shut Suction Lift Max Shut OFF
30 40 50 60 30 40 50 60
Depth (feet) OFF PSI Depth (feet) PSI
Discharge Capacity US GPM Discharge Capacity US GPM
5 14 13 8.5 6 80 5 22 21 15.9 10 79
10 13 12 8 5 78 10 22 21 14.5 8.5 77
15 12 11 7 4 76 15 21 20 12.6 7.2 75
20 10 9 6 3 74 20 20 18.5 10.6 5 73
25 9 7 5 2 72 25 20 18 10.3 4 71

JCRH 10

Discharge Pressure - PSI


Suction Lift Max Shut OFF
30 40 50 60
Depth (feet) PSI
Discharge Capacity US GPM
5 14 14 12 9 102
10 13.5 13.5 10 7.5 100
15 13 13 9.8 7 98
20 13 12.5 9 6.5 96
25 12 11 8 6 94

DIMENSIONS AND WEIGHT

f n
a
DN2
h2
DN1
h
h1

s
w n1

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN1 DN2 a f h h1 h2 n n1 w s 1~ 3~
JCR 05 JCR 05 1" 1" 3.5 13.9/ 13.6 6.9 4.8 2.0 6.3 4.7 3.7 0.4 15.2 14.3
JCR-JCRH 07 JCR-JCRH 07 1 1/4" 1" 4.6 16.0 8.1 5.7 2.2 7.2 5.3 4.3 0.4 20.7 21.2
JCR-JCRH 10 JCR-JCRH 10 1 1/4" 1" 4.6 16.0 8.1 5.7 2.2 7.2 5.3 4.3 0.4 23.8 22.9

39
JD “JET” self-priming pumps for deep wells

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 16 gpm • PUMP BODY: cast iron, with threaded ports.

LIMITS OF USE
• EJECTOR BODY: cast iron
• NOZZLE, VENTURI AND DIFFUSER: technopolymer.
Manometric suction lift up to 147 ft • IMPELLER: technopolymer.
Liquid temperature up to + 104°F • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
Environment temperature up to + 104°F • MECHANICAL SEAL: ceramic - graphite - NBR.
• ELECTRIC MOTOR: the pumps are close-coupled to a carefully
CONSTRUCTION AND SAFETY STANDARDS matched PEDROLLO electric motor, quiet running, totally enclosed
EN 60 335-1 EN 60034-1 fan cooled (TEFC), suitable for continuous duty.
IEC 335-1 IEC 34-1 JDWm: single-phase 115 V or 230 V - 60 Hz with capacitor and
CEI 61-150 CEI 2-3 thermal overload protector.
JDW: three-phase 230/460 V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 44.
INSTALLATION AND USE
OPTIONS ON REQUEST
JDW SELF-PRIMING PUMPS ARE DESIGNED FOR LIFTING WATER
FROM DEPTHS GREATER THAN 10 ft, INCLUDING CASES WITH ⇒ Impeller in technopolymer (JD...X - JD...X)
ENTRAINED AIR. THEY ARE RECOMMENDED FOR DOMESTIC USE ⇒ other voltages or frequency 50 Hz
INCLUDING WATER DISTRIBUTION (AS PART OF A PRESSURE
SET), GARDEN IRRIGATION, ETC. DESCRIPTION JD4 30/20/10 03
The pumps must be installed in enclosed places, or at least protected
against inclement weather. Series
Type of nozzle and venturi
GUARANTEE 2 YEARS subject to our general terms of sale. Motor size

40
4” “JET” self-priming pumps for 4” deep wells

FLOW RATE GPM


MODEL HS
HP 0 0.5 1 1.6 2.1 2.7 3.2 3.7 4.2 4.8 5.3 6.4 6.4
Feet
1 PH 3 PH FEET
JD430 07 JD430 07 174 164 151 138 128 121 112 101 95 88 78 65
JD420 07 JD420 07 50 131 118 112 105 98 92 89 85 80 75 72 62 59
JD410 07 JD410 07 98 95 92 89 85 84 82 78 75 72 68 65 63
0.7
JD430 07 JD430 07 65 102 92 85 82 75 71 66 60 55 52 49 42 41
JD430 07 JD430 07 95 69 66 59 56 52 51 49 45 42 39 37 36 32
JD430 07 JD430 07 115 118 105 89 79 66 56 46 39

HS: SUCTION HEIGHT

DIMENSIONS AND WEIGHT

MODEL SUCTION/DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DNp DN1 DN2 DN3 DN4 De a a1 a2 f h h1 h2 n n1 w s 1~ 3~
JD4 07 JD4 07 4" 1 1/4" 1" 1" 1" 3.8 2.7 1.8 5.8 13.8 13.8 3.6 7.1 7.1 7.1 0.9 0.4 36.2 34
*Weight includes the Eyector

41
3” JDW self-priming pumps for 3” deep wells

FLOW RATE GPM


MODEL HS
HP 0 0.5 1 1.6 2.1 2.7 3.2 3.7 4.2
Feet
1 PH 3 PH FEET
50 128 115 105 95 89 82 72 66 56
JD3 07 JD3 07 0.70 65 108 98 89 75 69 56
95 89 79 72
HS: SUCTION HEIGHT

DIMENSIONS AND WEIGHT

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS *


1 PH 3 PH DNp DN1 DN2 DN3 DN4 De a 123 540 242 108 207 206 164 22 10 25.5 1~ 3~
JD3 07 JD3 07 3" 1" 1" 3/4" 1" 2.8 2.7 1.8 5.1 13.8 7.9 3.6 7.1 7.1 5.7 0.9 0.4 34.7 32.5
*Weight includes the Eyector

42
2” JDW self-priming pumps for 2” deep wells

FLOW RATE GPM


MODEL HS
HP 0 0.5 1 1.6 2.1 2.7 3.2 3.7 4.2 4.8 5.3
Feet
1 PH 3 PH FEET
50 177 164 151 141 128 118 112 102 92 82 75
65 131 115 102 92 82 75 66 59 52
JD2 07 JD2 07 0.70 82 115 102 92 85 75 66 56
95 92 79 69 56
115 75 59 49
HS: SUCTION HEIGHT

DIMENSIONS AND WEIGHT

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DNp DN1 DN2 DN3 De a a1 a2 f h h1 h2 n n1 w s 1~ 3~
JD2 07 JD2 07 2" 1 1/4" 1" 1" 5.2 1.8 4.8 18.1 7.9 3.6 7.1 7.1 5.7 0.9 0.4 0.7 38.2 36

43
PLURIJET self-priming multi-stage pumps

New self-priming
pumps, quiet running,
reliable, high efficiency,
patented.

RANGE OF PERFORMANCE GUARANTEE 2 YEARS subject to our general terms of sale.


Flow rate up to 52 gpm
Head up to 394 ft CONSTRUCTION CHARACTERISTICS

LIMITS OF USE
• PUMP BODY: cast iron and stainless steel AISI 304 (cast iron up
to 0.7 HP), with threaded ports.
Manometric suction lift up to 29 ft • IMPELLER: technopolymer (approved for drinking water).
Liquid temperature up to + 104°F • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104
Environment temperature up to + 104°F • MECHANICAL SEAL: ceramic - graphite - NBR.
• ELECTRIC MOTOR: the pumps are close-coupled to a carefully
CONSTRUCTION AND SAFETY STANDARDS matched PEDROLLO electric motor, quiet running, totally enclosed
EN 60 335-1 EN 60034-1 fan cooled (TEFC), suitable for continuous duty.
IEC 335-1 IEC 34-1 PLURIJETm: single-phase 115 V or 230 V - 60 Hz with capacitor
CEI 61-150 CEI 2-3 and thermal overload protector.
PLURIJET: three-phase 230/460 V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 44.
INSTALLATION AND USE • REGISTERED MODEL

They are recommended for clean water and liquids that are chemically .
OPTIONS ON REQUEST
non aggressive to the materials from which the pump is made.
PLURIJET SELF-PRIMING PUMPS ARE DESIGNED FOR LIFTING ⇒ version in stainless steel EN 10088-3 - 1.4401 (AISI 316)
WATER, EVEN IN CASES WITH ENTRAINED AIR. THEIR QUIET ⇒ other voltages or frequency 50 Hz
RUNNING, RELIABILITY AND LOW POWER CONSUMPTION
MAKES THEM PARTICULARLY SUITABLE FOR DOMESTIC AND
CIVIL USE, INCLUDING PRESSURISATION AND DISTRIBUTION OF
WATER, IRRIGATION AND RAINWATER RECOVERY SYSTEMS.
The pumps must be installed in enclosed places, or at least protected
against inclement weather.

44
CURVES AND PERFORMANCE DATA

Head H (meters)
Head H (feet)

Flow Rate Q

MODEL FLOW RATE GPM 0 1 2 7 7 10 13 15 18 21


HP
1 PH 3 PH FLOW RATE l/min 0 5 10 30 30 40 50 60 70 80
PJ20 04 PJ20 04 0.4 125 118 113 105 95 82 66 51 34 16
PJ20 05 PJ20 05 0.5 164 158 153 141 126 110 92 74 54 33
H Feet
PJ20 10 PJ20 10 1.0 250 250 241 230 215 299 177 154 133 108
PJ20 15 PJ20 15 1.5 306 306 297 283 266 245 220 195 171 141

DIMENSIONS AND WEIGHT

PJ20 04 - 05 PJ20 10 - 15

f n
f n
a DN2
DN2
h2
DN1
h2
DN1

h
h1
h
h1

s
a w n1
w s
f

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN1 DN2 a f h h1 h2 n n1 w s 1~ 3~
PJ20 04 PJ20 04 1" 1" 4.3 13.1 6.8 5.3 1.5 6.2 4.6 0.1 0.4 20.7 19.6
PJ20 05 PJ20 05 1" 1" 5.3 14.4 /14.1 6.8 5.3 1.5 6.2 4.6 0.1 0.4 23.8 22.5
PJ20 10 PJ20 10 1 1/4 1" 2.7 25.0 9.1 6.0 1.8 7.3 5.7 12.0 0.4 56.3 51.9
PJ20 15 PJ20 15 1 1/4 1" 2.7 26.2 9.1 6.0 1.8 7.3 5.7 13.2 0.4 60.7 59.6

45
CURVES AND PERFORMANCE DATA

Head H (meters)
Head H (feet)

Flow Rate Q

MODEL FLOW RATE GPM 0 1.3 2.6 5.2 7.9 10.6 13 15 18 21 26 31 34


HP
1 PH 3 PH FLOW RATE l/min 0 5 10 20 30 40 50 60 70 80 100 120 130
PJ30 05 PJ30 05 0.5 118 117 115 110 105 99 92 85 76 66 44 16
PJ30 07 PJ30 07 0.7 151 148 141 138 131 125 117 108 99 87 62 33 16
PJ30 10 PJ30 10 1.0 164 163 161 158 151 148 145 140 133 126 112 89 79
H Feet
PJ30 15 PJ30 15 1.5 214 214 210 207 204 197 191 184 174 164 141 115 102
PJ30 20 PJ30 20 2.0 266 266 263 260 253 246 240 230 217 207 177 145 128
PJ30H 20 2.0 319 319 315 312 302 296 286 273 260 246 210 171 151

DIMENSIONS AND WEIGHT

PJ30 05 - 07 PJ30 10 - 15 - 20
n n
f n
a DN2
DN2
h2
DN1
h2
DN1

h
h1
h
h1

s
a w n1
w
n1

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN1 DN2 a f h h1 h2 n n1 w s 1~ 3~
PJ30 05 PJ30 05 1" 1" 4.3 13.5 / 13.1 6.8 5.3 1.5 6.2 4.6 0.1 0.4 22.5 20.7
PJ30 07 PJ30 07 1" 1" 5.3 14.9 7.5 5.3 2.4 6.2 4.6 0.1 0.4 29.6 27.1
PJ30 10 PJ30 10 1 1/4" 1" 2.7 22.5 9.1 6.0 1.8 7.3 5.7 9.5 0.4 51.9 47.7
PJ30 15 PJ30 15 1 1/4" 1" 2.7 23.7 9.1 6.0 1.8 7.3 5.7 10.7 0.4 57.2 55.2
PJ30 20 PJ30 20 1 1/4" 1" 2.7 25.0 9.1 6.0 1.8 7.3 5.7 12.0 0.4 60.7 59.6
PJ30H 20 1 1/4" 1" 2.7 26.2 9.1 6.0 1.8 7.3 5.7 13.2 0.4 64.0

46
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 5 10 13 15 21 26 31 37 42 47 52


HP
1 PH 3 PH FLOW RATE l/min 0 20 40 50 60 80 100 120 140 160 180 200
PJ50 10 PJ50 10 1 148 141 138 135 131 125 115 105 92 76 59 43
PJ50 15 PJ50 15 1.5 191 187 181 177 174 161 148 131 115 99 79 56
H Feet
PJ50 20 PJ50 20 2 240 233 227 223 217 204 184 168 145 125 99 72
PJ50H 20 2 286 279 269 263 256 240 220 197 174 148 118 85

DIMENSIONS AND WEIGHT

n n
DN2
h2
DN1

h
h1

s
a w
n1

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN1 DN2 a f h h1 h2 n n1 w s 1~ 3~
PJ50 10 PJ50 10 1 1/4" 1" 2.7 22.5 9.1 6.0 1.8 7.3 5.7 9.5 0.4 51.9 47.7
PJ50 15 PJ50 15 1 1/4" 1" 2.7 23.7 9.1 6.0 1.8 7.3 5.7 10.7 0.4 57.2 55.2
PJ50 20 PJ50 20 1 1/4" 1" 2.7 25.0 9.1 6.0 1.8 7.3 5.7 12.0 0.4 60.7 59.6
PJ50H 20 1 1/4" 1" 2.7 26.2 9.1 6.0 1.8 7.3 5.7 13.2 0.4 64.0

47
Bz pumps with bronze body

RANGE OF PERFORMANCE GUARANTEE 2 YEARS subject to our general terms of sale.


Flow rate up to 24 gpm
Head up to 180 ft. CONSTRUCTION CHARACTERISTICS

LIMITS OF USE
• PUMP BODY: bronze, with threaded ports.
• MOTOR BRACKET (patent nº 1289150) PK-Bz, PQ-Bz:
Liquid temperature up to + 194°F aluminium with brass front insert.
Environment temperature up to + 104°F • BODY BACK-PLATE: CP-Bz: stainless steel AISI 316.
• IMPELLER: PK-Bz, PQ-Bz: brass.
CONSTRUCTION AND SAFETY STANDARDS CP-Bz: stainless steel AISI 316
EN 60034-1 • MOTOR SHAFT: stainless steel AISI 316.
IEC 34-1 • MECHANICAL SEAL: ceramic - graphite - VITON.
CEI 2-3 • ELECTRIC MOTOR: induction motor, for continuous duty.
Single-phase: 115 V or 230 V - 60 Hz with capacitor and thermal
overload protector.
INSTALLATION AND USE Three-phase: 230/460 V - 60 Hz.

They are recommended for pumping clean water without abrasive


• INSULATION: class F. • PROTECTION: IP 44.

particles and liquids that are chemically non aggressive to the materials
OPTIONS ON REQUEST
from which the pump is made. THE NON-FERROUS CONSTRUCTION
GUARANTEES AGAINST RUST AND OXIDATION. THE COMPACT ⇒ special mechanical seal
DESIGN AND HYDRAULIC CHARACTERISTICS SUIT INDUSTRIAL ⇒ other voltages or frequency 50 Hz
APPLICATIONS INCLUDING COOLING AND CONDITIONING ⇒ protection IP 55
SYSTEMS. ⇒ for liquids with higher temperatures
The pumps must be installed in enclosed places, or at least protected ⇒ for environments with higher temperatures
against inclement weather.

48
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 1.3 2.6 3.9 5.2 6.6 7.9 9.2 10.5 13.2 15.8
HP
1 PH 3 PH FLOW RATE l/min 0 5 10 15 20 25 30 35 40 50 60
PKBZ 03 PKBZ 03 0.33 131 124 110 95 78 64 49 32 16
H Feet
PKBZ 05 PKBZ 05 0.5 181 164 149 133 118 101 88 72 55 26

DIMENSIONS AND WEIGHT

f i
DN2
h2

h
h3
DN1

h1

s n1
a w m n

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN1 DN2 a f h h1 h2 h3 i m n n1 w s 1~ 3~
PKBZ 03 PKBZ 03 1" 1" 1.7 9.5 5.9 2.4 2.9 5.4 0.7 3.1 4.7 3.9 2.1 0.2 11.7 11.7
PKBZ 05 PKBZ 05 1" 1" 1.9 10.2/9.8 5.9 2.4 3.1 5.6 0.7 3.1 4.7 3.9 2.1 0.2 17.0 14.1

49
CURVES AND PERFORMANCE DATA

Head H (meters)
H Head H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 1.3 2.6 3.9 5.2 6.6 7.9 9.2 10.5 13.2 15.8
HP
1 PH 3 PH FLOW RATE l/min 0 5 10 15 20 25 30 35 40 50 60
PQBZ 03 PQBZ 03 0.33 131 124 110 95 78 64 49 32 16
H Feet
PQBZ 05 PQBZ 05 0.5 181 164 149 133 118 101 88 72 55 26

DIMENSIONS AND WEIGHT

f i
DN2
h2
DN1

h
h3
h1

s n1
a w m n

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN1 DN2 a f h h1 h2 h3 i m n n1 w s 1~ 3~
PQBZ 03 PQBZ 03 1" 1" 1.7 9.5 5.9 2.4 2.9 5.4 0.7 3.1 4.7 3.9 2.1 0.2 11.7 11.7
PQBZ 05 PQBZ 05 1" 1" 1.9 10.2/9.85 5.9 2. 3.1 5.6 0.7 3.1 4.7 3.9 2.1 0. 17 14.1

50
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Flow Rate QQ

MODEL FLOW RATE GPM 0 2.6 5.2 7.9 10.5 13.2 15.8 18.5 21 23.8
HP
1 PH 3 PH FLOW RATE l/min 0 10 20 30 40 50 60 70 80 90
CPBZ 03 CPBZ 03 0.33 76 72 69 66 62 59 56 51 46
H Feet
CPBZ 07 CPBZ 07 0.7 118 112 108 108 105 102 99 95 89 82

DIMENSIONS AND WEIGHT

f n
a
DN2
h2
h
DN1

h1

w s
n1

MODEL SUCTION /DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN1 DN2 a f h h1 h2 n n1 W s 1~ 3~
CPBZ 03 CPBZ 03 1" 1" 1.7 10.2 8.1 3.2 4.8 6.5 5.3 1.6 0.4 18.8 18.3
CPBZ 07 CPBZ 07 1" 1" 1.7 11.2 9.4 3.6 5.8 7.5 6.3 1.5 0.4 28.3 27.2

51
TOP SUMP pumps
for clear water

Already recognized for their


innovative design and safety
features, TOP pumps combine
a stainless steel internal motor
housing with technologically
advanced materials to give an
exceptionally robust
construction.

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 105 gpm • DELIVERY BODY: glass filled technopolymer, particularly resistant to
Head up to 48 ft impact and corrosion, with threaded port.
• SUCTION GRID: technopolymer.
LIMITS OF USE • IMPELLER: open type in technopolymer.
Depth up to 16 ft (10 ft up to 0.55 Hp) • MOTOR SUPPORT: stainless steel AISI 304.
Liquid temperature up to 104°f • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
(+194°f for a maximum period of 3 minutes)
• DOUBLE SEAL: mechanical seal ceramic -graphite - NBR, with oil barrier
chamber and inner lip seal to protect the seal in the event of dry running.
Passage of solid bodies up to 4/10” • MOTOR: submersible asynchronous single-phase for continuous duty.
Drainage level: TOP: single-phase 115 V or 230 V - 60 Hz with capacitor and thermal
1/2” from the bottom for TOP up to 0.5 Hp overload protector built into the winding.
1 1/16” from the bottom for TOP 0.7 and 1.0 Hp • INSULATION: class F. • PROTECTION: IP 68.
• REGISTERED MODEL nº 72765.
INSTALLATION AND USE
TOP
THE TOP SERIES IS SUITABLE FOR DRAINING CLEAR WATER STANDARD FEATURES:
WITHOUT ABRASIVE PARTICLES. THE CONSTRUCTION TOP
TOP up to 0.5 Hp (single-phase) Float switch.
GUARANTEES SIMPLE AND SAFE OPERATION DUE TO THE Hosetail.
Power cable in neoprene “H05 RN-F”
COMPLETE COOLING OF THE MOTOR BY THE PUMPED WATER length 15 ft
AND THE DOUBLE SEAL DESIGN. THEY ARE RECOMMENDED
FOR EMERGENCY DRAINING OF SMALL FLOODED AREAS
TOP
TOP 0.7 and 1 Hp (single-phase) Float switch.
• Hosetail.
(ROOMS, CELLARS, GARAGES), FOR THE DISPOSAL OF WASTE • Coupling with flap valve.
WATER IN THE HOME (DISHWASHER, WASHING MACHINE) AND Neoprene power cable “H05 RN-F” length 30 feet
FOR EMPTYING DRAINAGE TRAPS.

GUARANTEE 2 YEARS subject to our general terms of sale. OPTIONS ON REQUEST


⇒ pumps for aggressive liquids TOP - LA
⇒ special mechanical seal
⇒ 30 ft power cable.
N.B. required for outdoor use to comply with standard EN 60335-2-41
⇒ versions without float switch
⇒ other voltages or frequency 50 Hz

52
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Flow Rate Q Q

MODEL FLOW RATEGPM 0 5 10 15 21 26 31 37 42 47 52 58 63 68 74 79 84 89 95 100 105


HP
1 PH FLOW RATE l/min 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400
TOP 025 0.25 22 19 18 14 11 8 6 3
TOP 03 0.33 29 26 24 21 19 18 14 13 9 8 5 3
TOP 05 0.5 H Feet 34 32 29 28 26 24 21 19 18 15 13 11 8 6
TOP 07 0.7 41 39 37 35 32 30 28 26 23 21 19 17 15 13 10 8 6
TOP 10 1.0 47 45 44 41 39 37 35 33 31 29 27 25 23 20 19 17 14 12 10 8 6

DIMENSIONS AND WEIGHT

Typical installation

DN
p minimum
h1
h

e
d

a minimum

MODEL DISCH DIMENSIONES INCHES


LBS
1 PH DN a h h1 d e p min
TOP 025 1" 9.1 8.5 9.1
TOP 03 5.9 10.1 9.3 14 13.7 13.7 11.1
1 1/4"
TOP 05 11.3 10.5 ADJUSTABLE 14.1
TOP 07 21.7
1 1/2" 8.0 13.1 12.2 0.8 17.7 17.7
TOP 10 23.9

53
TOPFLOOR SUMP pumps
for clear water

The particular
constructive design of
the TOP FLOOR pump
allows draining down to
a level of 1/8” above the
floor.

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 58 gpm • DELIVERY BODY: glass filled technopolymer, particularly resistant
Head up to 29 ft to impact and corrosion, with threaded port.

LIMITS OF USE
• SUCTION GRID: technopolymer.
• IMPELLER: open type in technopolymer.
Depth up to 10 ft • MOTOR SUPPORT: stainless steel AISI 304.
Liquid temperature up to 104°f • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
(194°f for a maximum period of 3 minutes) • DOUBLE SEAL: mechanical seal ceramic - graphite - NBR, with oil barrier
Drainage level 1/8” from the bottom chamber and inner lip seal to protect the seal in the event of dry running.
• MOTOR: submersible asynchronous single-phase for continuous duty.
CONSTRUCTION AND SAFETY STANDARDS TOP-FLOOR: single-phase 115 V or 230 V - 60 Hz with capacitor and
thermal overload protector.
EN 60 335-1 EN 60034-1
• INSULATION: class F. • PROTECTION: IP 68.
IEC 335-1 IEC 34-1
• REGISTERED MODEL nº 72765
CEI 61-150 CEI 2-3

STANDARD FEATURES:
INSTALLATION AND USE TO
T OP
P-- F
FL
LOOO
ORR Neoprene power cable “H05 RN-F”

THE TOP-FLOOR SERIES IS SUITABLE FOR DRAINING CLEAR length 15 ft


WATER WITHOUT ABRASIVE PARTICLES. THEIR ABILITY TO Hosetail.
DRAIN WATER DOWN TO 1/8” FROM THE FLOOR MAKES THEM
IDEAL FOR EMERGENCY DOMESTIC USE FOR SMALL FLOODED OPTIONS ON REQUEST
AREAS AND IN ALL THOSE APPLICATIONS WHERE MAXIMUM ⇒ versions with external float switch
DRAINAGE IS REQUIRED. ⇒ special mechanical seal
GUARANTEE 2 YEARS subject to our general terms of sale.
⇒ 30 ft power cable.
N.B. required for outdoor use to comply with standard EN 60335-2-41
⇒ other voltages or frequency 50 Hz

54
CURVES AND PERFORMANCE DATA

Head H (meters)
Head H (feet)

Flow Rate Q

MODEL FLOW RATE GPM 0 5 10 15 21 26 31 37 42 47 52 58


HP
1 PH FLOW RATE l/min 0 20 40 60 80 100 120 140 160 180 200 220
TOPF 025 0.25 22 19 18 14 11 8 6 3
H Feet
TOPF 03 0.3 29 26 24 21 19 18 14 13 9 8 5 3

DIMENSIONS AND WEIGHT

Typical installation

DN
Draining Down to1/8”
h1
h

MODEL DISCH DIMESIONS [INCHES] Minimum Suction


LBS
1 PH DN a h h1 Level [INCHES]
TOPF 025 1" 5.9 9.1 8.5 8.6
0.1
TOPF 03 1 1/4" 5.9 10.1 9.3 10.8

55
TOPVORTEX VORTEX SUMP pump
for dirty water

Thanks to the proven


VORTEX system, this
submersible pump
allows the clearing of
dirty water containing
suspended solid bodies
without any risk of
clogging the impeller.

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 47 gpm • DELIVERY BODY: glass filled technopolymer, particularly resistant
Head up to 23 ft to impact and corrosion, with threaded port.

LIMITS OF USE • SUCTION GRID: technopolymer.


• IMPELLER: technopolymer.
Depth up to 10 ft
Liquid temperature up to 104°f
• MOTOR SUPPORT: stainless steel AISI 304.

(194° f for a maximum period of 3 minutes)


• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
Passage of solid bodies up to Ø 3/4” • DOUBLE SEAL: mechanical seal ceramic - graphite - NBR, with oil barrier
Drainage level 1” from the bottom chamber and inner lip seal to protect the seal in the event of dry running.
• MOTOR: submersible asynchronous single-phase for continuous duty.
TOP-VORTEX: single-phase 115 V or 230 V - 60 Hz with capacitor and
CONSTRUCTION AND SAFETY STANDARDS thermal overload protector.
EN 60 335-1 EN 60034-1 • INSULATION: class F. • PROTECTION: IP 68.
IEC 335-1 IEC 34-1 • REGISTERED MODEL nº 72765
CEI 61-150 CEI 2-3
STANDARD FEATURES:
INSTALLATION AND USE
TO
T OP
P-- V
VO
ORRT
TEEX
X Float switch.
THE T TO
OPP-
-VVO
ORRT
TEEX
X PUMP IS SUITABLE FOR DRAINING DIRTY
WATER THAT IS CHEMICALLY NON AGGRESSIVE. THE Hosetail.
CONSTRUCTION GUARANTEES SIMPLE AND SAFE OPERATION Neoprene power cable “H05 RN-F”
DUE TO THE COMPLETE COOLING OF THE MOTOR BY THE length 15 ft.
PUMPED WATER AND THE DOUBLE SEAL DESIGN.
IT IS RECOMMENDED FOR DOMESTIC USE, FOR THE CLEARING
OPTIONS ON REQUEST
OF DIRTY WATER, FOR EMPTYING TANKS, DOMESTIC DRAINS
AND COLLECTION TRAPS, EVEN WITH SUSPENDED SOLID ⇒ special mechanical seal
BODIES WITH DIMENSIONS UP TO Ø 3/4”. ⇒ 30 ft power cable.
N.B. required for outdoor use to comply with standard EN 60335-2-41
GUARANTEE 2 YEARS subject to our general terms of sale. ⇒ other voltages or frequency 50 Hz

56
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 5 10 15 21 26 31 37 42 47


HP
1 PH FLOW RATE l/min 0 20 40 60 80 100 120 140 160 180
TOPV 03 0.33 H Feet 23 21 19 17 15 13 11 9 8 4

DIMENSIONS AND WEIGHT

Typical installation

DN
p minimum
h1
h

a
d

minimum

MODEL DISCH DIMENSIONS INCHES


LBS
1 PH DN a h h1 d e p min
TOPV 03 1 1/4" 6.0 11.3 10.6 1.0 adjustable 13.7 13.7 11.0

57
TOP MULTI
multi-stage submersible pumps
for clear water

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 26 gpm
• DELIVERY BODY AND SUCTION GRID: glass filled
Head up to 137 ft technopolymer, particularly resistant to impact and corrosion, with
LIMITS OF USE threaded port.
Submersion depth up to 32 ft • IMPELLERS and DIFFUSERS: technopolymer.
Liquid temperature up to + 104°f • DIFFUSER CONTAINER: stainless steel AISI 304.
Emptying level up to 1 1/16” from the bottom • MOTOR SUPPORT: stainless steel AISI 304.
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• DOUBLE SEAL: mechanical seal ceramic -silicon carbide-NBR, with
oil barrier chamber and inner lip seal to protect the seal in the event
CONSTRUCTION AND SAFETY STANDARDS
of dry running.
EN 60 335-1 EN 60034-1 • MOTOR: asynchronous, for continuous duty.
IEC 335-1 IEC 34-1 TOP M: single-phase 115 V or 230 V - 60 Hz with capacitor and
CEI 61-150 CEI 2-3 thermal overload protector.
• INSULATION: class F. • PROTECTION: IP 68.
• REGISTERED MODEL n° 72765.
INSTALLATION AND USE
THEY ARE RECOMMENDED FOR PUMPING CLEAN WATER. STANDARD FEATURES:
THEIR HIGH EFFICIENCY AND RELIABILITY MAKES THEM
TO
T OP
P-- M
MUUL
LT
TII Float switch
SUITABLE FOR SUPPLYING DOMESTIC WATER FROM TANKS,
Neoprene power cable “H05 RN-F” length 30 ft
RESERVOIRS OR RELATIVELY DEEP WELLS, DRAWING
Hosetail.
RAINWATER FROM CISTERNS, WATERING BY HAND OR FEEDING.
Coupling with non-return valve.

GUARANTEE 2 YEARS subject to our general terms of sale. OPTIONS ON REQUEST


⇒ other voltages or frequency 50 Hz

58
CURVES AND PERFORMANCE DATA

Head H (meters)
Head H (feet)

Flow Rate Q

MODEL FLOW RATE GPM 0 2 5 7 10 13 14 18 21 23 26


HP
1 PH FLOW RATE l/min 0 10 20 30 40 50 55 70 80 90 100
TOPM 03 0.33 118 108 100 87 71 48 16
TOPM 05 0.5 H Feet 98 95 92 89 85 79 72 62 49 34 16
TOPMH 05 0.5 138 125 115 102 82 57 26

DIMENSIONS AND WEIGHT

Typical portable application

DN
h1

p minimum
h

a
d

minimum

MODEL DISCHARGE DIMENSIONS INCHES


Stages LBS
1 PH DN a h h1 d min e p min
TOPM 03 6 18.6
14.96 13.58
TOPM 05 1 1/4" 5 6.90 1.18 13.7 13.7 17.9
TOPMH 05 7 15.75 13.58 19.7

59
RX SUMP pumps
for clear water

Robust high-quality submersible


pumps in stainless steel, for
drainage of clear water.
Recommended for fixed
installations or for draining
domestic water or rainwater,
and for emptying tanks or
reservoirs.

RANGE OF PERFORMANCE GUARANTEE 2 YEARS subject to our general terms of sale.


Flow rate up to 79 gpm
Head up to 75 ft CONSTRUCTION CHARACTERISTICS
LIMITS OF USE • DELIVERY BODY: stainless steel AISI 304, with threaded port
Depth up to 30 ft • SUCTION GRID: stainless steel AISI 304.
Liquid temperature up to 120°f • IMPELLER: stainless steel AISI 304.
Liquid temperature up to 104°f for intermittent duty. • MOTOR SUPPORT: stainless steel AISI 304.
Liquid temperature up to 194°f for intermittent duty maximum 3 minutes. • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
Passage of solid bodies up to Ø 3/8” • DOUBLE SEAL: mechanical seal ceramic - graphite - NBR, with oil barrier
Drainage level: chamber and inner lip seal to protect the seal in the event of dry running.
1/2” from the bottom for RX up to 0.33 hp • MOTOR: submersible asynchronous single-phase for continuous duty.
1” from the bottom for RX 0.50 Hp, 0.75 Hp, and 1.0 Hp RXm: single-phase 115 V or 230 V - 60 Hz with capacitor and thermal
overload protector.
RX: three-phase 230V - 60 Hz.
CONSTRUCTION AND SAFETY STANDARDS • INSULATION: class F. • PROTECTION: IP 68.
EN 60 335-1 EN 60034-1 • REGISTERED MODEL.
IEC 335-1 IEC 34-1
CEI 61-150 CEI 2-3 STANDARD FEATURES:
RX
RX (single-phase) float switch.
Neoprene power cable “H05 RN-F”
INSTALLATION AND USE length 15 feet
RX PUMPS ARE SUITABLE FOR DRAINING CLEAR WATER RX
RX (three-phase) Neoprene power cable “H05 RN-F”
WITHOUT ABRASIVE PARTICLES. length 15 feet
THE CONSTRUCTION GUARANTEES SIMPLE AND SAFE
OPERATION DUE TO THE COMPLETE COOLING OF THE MOTOR
BY THE PUMPED WATER, AND THE DOUBLE SEAL DESIGN. THEY OPTIONS ON REQUEST
ARE RECOMMENDED FOR FIXED INSTALLATIONS, EMERGENCY
⇒ special mechanical seal
DRAINING OF SMALL FLOODED AREAS (BASEMENT ROOMS,
CELLARS, GARAGES), FOR DISPOSAL OF DIRTY WATER USED IN
⇒ 30 feet power cable.
N.B. required for outdoor use to comply with standard EN 60335-2-41
THE HOME BY WASHING MACHINES AND DISHWASHERS AND
⇒ control box for three-phase electropumps 1 Hp
FOR DRAINING COLLECTION TRAPS. ⇒ single-phase versions without float switch
⇒ other voltages or frequency 50 Hz

60
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 5 10 15 21 26 31 37 42 47 52 58 63 68 74 79


HP
1 PH 3 PH FLOW RATE l/min 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300
RX 025 0.25 25 21 19 16 14 11 9 7
RX 030 RX 030 0.33 33 31 29 26 24 21 19 16 14 11 9 7
RX 05 RX 05 0.5 H Feet 56 52 49 45 42 38 34 31 28 24 21 17 13 10
RX 07 RX 07 0.7 66 62 59 55 52 48 44 41 38 34 31 27 24 20 16
RX 10 RX 10 1.0 75 72 69 66 62 58 54 51 48 44 41 37 33 30 26 23

DIMENSIONS AND WEIGHT

Typical single-phase installation

DN
p minimum
h1
h

e
d

a minimum

MODEL DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN a h h1 d e p min 1~ 3~
RX 025 10
1 1/4" 5.7 10.0 9.7 0.6 13.8 13.8
RX 030 RX030 13 12
RX 05 RX 05 Adjustable 27 24
RX 07 RX 07 1 1/2" 8.4 13.9 13.2 1.1 19.7 19.7 29 26
RX 10 RX 10 31 28

61
RXVORTEX SUMP pump
for dirty water

Robust high-quality
VORTEX submersible
pumps in stainless
steel. The proven
VORTEX system allows
the clearing of dirty
water containing
suspended solids.

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 118 gpm • DELIVERY BODY: stainless steel AISI 304, with threaded port
Head up to 47ft • SUCTION GRID: stainless steel AISI 304.
LIMITS OF USE • IMPELLER: stainless steel AISI 304.
Depth up to 10 m • MOTOR SUPPORT: stainless steel AISI 304.
Liquid temperature up to 122°f • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
Liquid temperature up to 104°f for intermittent duty. • DOUBLE SEAL: mechanical seal silicon carbide - NBR, with oil barrier
Liquid temperature up to 194°f for intermittent duty maximum 3 minutes. chamber and inner lip seal to protect the seal in the event of dry running.
Passage of solid bodies: • MOTOR: submersible asynchronous single-phase for continuous duty.
up to 3/4” for 0.33 hp - up to 1.5” from 0.5 Hp to 1.0 Hp RXm: single-phase 115V or 230 V - 60 Hz with capacitor and
Drainage level from the bottom:
thermal overload protector.
1” for 0.33 Hp - 1.5” from 0.5 Hp to 1.0 Hp
RX: three-phase 230V - 60 Hz.

CONSTRUCTION AND SAFETY STANDARDS


• INSULATION: class F. • PROTECTION: IP 68.
• REGISTERED MODEL.
EN 60 335-1 EN 60034-1
IEC 335-1 IEC 34-1 STANDARD FEATURES:
CEI 61-150 CEI 2-3 RXm
RXm (single-phase) float switch.
Neoprene power cable “H05 RN-F”
length 15 feet
INSTALLATION AND USE
RX -V OR TEX
RX -V OR TEX PUMPS ARE SUITABLE FOR DRAINING DIRTY RX
RX (three-phase) Neoprene power cable “H05 RN-F”
length 15 feet.
WATER. THE CONSTRUCTION GUARANTEES SIMPLE AND SAFE
OPERATION, DUE TO THE COMPLETE COOLING OF THE MOTOR
BY THE PUMPED WATER. THEY ARE RECOMMENDED FOR OPTIONS ON REQUEST
DOMESTIC USE, FOR DRAINING DIRTY WATER CONTAINING
⇒ special mechanical seal
SUSPENDED SOLIDS.
⇒ 30 feet power cable.
GUARANTEE 2 YEARS subject to our general terms of sale. N.B. required for outdoor use to comply with standard EN 60335-2-41
⇒ control box for three-phase pumps 1Hp
⇒ single-phase versions without float switch
⇒ other voltages or frequency 50 Hz

62
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 5 10 15 21 26 31 37 42 47 52 66 79 86 92 105 119


HP
1 PH 3 PH FLOW RATE l/min 0 20 40 60 80 100 120 140 160 180 200 250 300 325 350 400 450
RXV 025 0.25 23 21 20 18 16 14 12 10 8 7
RXV 030 RXV 030 0.33 30 28 26 24 22 21 19 17 15 13 11 7
H Feet
RXV 05 RXV 05 0.5 36 34 33 31 29 27 25 23 22 20 18 13 9 7
RXV 07 RXV 07 0.7 49 48 46 44 42 40 38 36 34 32 30 26 21 18 16 11 7

DIMENSIONS AND WEIGHT

Typical single-phase installation

DN
p minimum
h1
h

e
d

minimum
a

MODEL DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN a h h1 d e p min 1~ 3~
RXV 025 13.8 13.8 13 13
1 1/4" 5.8 10.0 9.7 0.7
RXV 030 RXV 030 27 25
Adjustable
RXV 05 RXV 05 0.5 0.5 30 27
1 1/2" 8.5 15.9 15.2 1.6
RXV 07 RXV 07 32 29

63
D DRAINAGE submersible pumps
for clear or slightly dirty water

DRAINAGE submersible
pumps for professional
use, particularly reliable
with generous motor
specification and hard-
faced mechanical seal.

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 105 gpm • DELIVERY BODY: cast iron, with threaded port ISO 228/1.
Head up to 88 ft • MOTOR CASING: stainless steel AISI 304.
LIMITS OF USE • SUCTION GRID: stainless steel AISI 304.
• IMPELLER: open type, in glass filled technopolymer
Depth up to 15 ft • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
Liquid temperature up to 104°f • DOUBLE SEAL: mechanical seal silicon carbide - NBR, with oil barrier
Passage of suspended solid bodies up to 3/8” chamber and inner lip seal to protect the seal in the event of dry running.
Drainage level 1/2” from the bottom • MOTOR: submersible asynchronous for continuous duty.
For continuous duty: minimum immersion 8.5” from pump base D: single-phase 115 V or 230 V - 60 Hz with capacitor and
thermal overload protector.
D: three-phase 230V - 60 Hz.
CONSTRUCTION AND SAFETY STANDARDS
• INSULATION: class F. • PROTECTION: IP 68.
EN 60 335-1 EN 60034-1
IEC 335-1 IEC 34-1 STANDARD FEATURES:
CEI 61-150 CEI 2-3 DD (single-phase) Float switch.
Neoprene power cable “H07 RN-F”
length 15 ft
INSTALLATION AND USE
DESIGNED FOR DRAINING CLEAR OR SLIGHTLY DIRTY WATER D
D (three-phase) Neoprene power cable “H07 RN-F”
WITH SMALL SOLIDS, THEY ARE RECOMMENDED FOR length 15 ft
DOMESTIC, CIVIL AND PROFESSIONAL USE, FOR DRAINING
FLOODED AREAS SUCH AS CELLARS AND GARAGES OR FOR
OPTIONS ON REQUEST
EMPTYING SWIMMING POOLS OR TANKS AND FOR DISPOSING
OF NON-SEWAGE WASTE WATER. THESE PUMPS ARE ⇒ 30 ft power cable.
OUTSTANDING IN THEIR RELIABILITY IN FIXED INSTALLATIONS N.B. required for outdoor use to comply with standard EN 60335-2-41
WITH AUTOMATIC OPERATION. ⇒ control box for three-phase pumps 1.0 Hp
⇒ single-phase pumps without float switch
GUARANTEE 2 YEARS subject to our general terms of sale. ⇒ other voltages or frequency 50 Hz

64
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 7 13 20 26 33 40 46 53 60 66 73 79 86 93 106


HP
1 PH 3 PH FLOW RATE l/min 0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 400
D 04 0.4 30 28 26 25 22 20 17 13 9 3
D 05 0.5 39 38 36 34 32 30 27 24 20 16 11 7
D 07 D 07 0.7 49 48 46 43 41 39 36 33 30 26 22 18 11 7
D 10 D 10 1 H Feet 64 62 61 59 57 54 52 49 46 43 39 34 30 26 23 13
DH 05 0.5 56 54 49 44 39 35 30 25 16
DH 07 DH 07 0.7 69 66 62 57 52 49 44 39 33
DH 10 DH 10 1 89 85 82 77 72 69 64 59 52 48 43 38 33

DIMENSIONS AND WEIGHT


Typical single-phase installation
a
p minimum
h

DN
e
h1

minimum
d

b c

MODEL DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN a b c h h1 d e p min 1~ 3~
D 04 23
D 05 4.1 3.1 5.3 12.6 2.6 26
D 07 D 07 29 26
D 10 D 10 1 1/2" 4.3 3.5 5.5 13.3 3.1 0.5 Adjustable 19.7 19.7 34 31
DH 05 27
4.1 3.1 5.3 12.6 2.6
DH 07 DH 07 29 26
DH 10 DH 10 4.3 3.5 5.5 13.3 3.1 34 31

65
VX VORTEX submersible pumps
for sewage water

VORTEX submersible pumps for


professional use, particularly
reliable with generous motor
specification and hard-faced
mechanical seal. The proven
VORTEX system allows the
clearing of dirty water
containing suspended solids.

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 132 gpm • DELIVERY BODY: cast iron, with threaded port
Head up to 49 ft • MOTOR CASING: stainless steel AISI 304.
• Base: stainless steel AISI 304.
LIMITS OF USE • IMPELLER: stainless steel AISI 304.
Depth up to 15 ft • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
Liquid temperature up to 104°f • DOUBLE SEAL: mechanical seal silicon carbide - NBR, with oil barrier
chamber and inner lip seal to protect the seal in the event of dry running.
Passage of suspended solid bodies up to 2”
For continuous duty: minimum immersion 11” from pump base
• MOTOR: submersible asynchronous for continuous duty.
VX: single-phase 115 V or 230V - 60 Hz with capacitor and
thermal overload protector.
CONSTRUCTION AND SAFETY STANDARDS VX: three-phase 230V - 60 Hz.

EN 60 335-1 EN 60034-1
• INSULATION: class F. • PROTECTION: IP 68.

IEC 335-1 IEC 34-1


CEI 61-150 CEI 2-3 STANDARD FEATURES:

INSTALLATION AND USE


VXX
V (single-phase) Float switch.
Neoprene power cable “H07 RN-F”
THEY ARE RECOMMENDED FOR DOMESTIC, CIVIL AND length 15 ft.
INDUSTRIAL USE, IN APPLICATIONS WHERE THE WATER
CONTAINS SUSPENDED SOLIDS WITH DIMENSIONS UP TO Ø 2 plg. VXX
V (three-phase) Neoprene power cable “H07 RN-F”
THEIR USE IS RECOMMENDED FOR DRYING FLOODED AREAS length 15 ft.
SUCH AS CELLARS, UNDERGROUND CAR PARKS, CAR WASHING
AREAS, OR DOMESTIC DRAINS AND FOR EMPTYING CESSPITS
OPTIONS ON REQUEST
OR SEWAGE DISPOSAL. THESE PUMPS ARE OUTSTANDING IN
THEIR RELIABILITY IN FIXED INSTALLATIONS WITH AUTOMATIC ⇒ 30 ft power cable.
N.B. required for outdoor use to comply to standard EN 60335-2-41
OPERATION.
⇒ control panel for three-phase pumps 1 Hp
GUARANTEE 2 YEARS subject to our general terms of sale. ⇒ single-phase pumps without float switch
⇒ other voltages or frequency 50 Hz

66
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Q
Flow Rate Q

MODEL FLOW RATE GPM 0 13 26 40 53 66 79 93 106 119 132


HP
1 PH 3 PH FLOW RATE l/min 0 50 100 150 200 250 300 350 400 450 500
VXH 05 0.5 28 25 21 17 12 7
VXH 07 VXH 07 0.7 33 31 28 24 19 13 7
VXH 10 VXH 10 1 49 46 43 39 34 30 25 20 13 7
H Feet
VX 05 0.5 20 18 16 14 12 9 7 3
VX 07 VX 07 0.7 25 23 21 19 16 13 10 8 5
VX 10 VX 10 1 36 34 33 31 30 27 25 22 20 16 13

DIMENSIONS AND WEIGHT

Typical single-phase installation


a
p minimum

DN
h

e
h1

b c
minimum
d

MODEL DISCH Passage of DIMENSIONS INCHES LBS


1 PH 3 PH DN Solid bodies a b c h h1 d e p min 1~ 3~
VXH 05 27.4
4.1 3.4 5.4 15.0 4.8 1.6
VXH 07 VXH 07 1 1/2" 1 1/2" 29.8 26.7
VXH 10 VXH 10 3.6 5.6 15.7 5.2 34.7 32.3
4.3 2.2 Adjustable 19.7 19.7
VX 05 29.6
3.5 5.9 16.1 6.0
VX 07 VX 07 2" 2" 30.7 26.7
4.7 2.6
VX 10 VX 10 3.8 6.4 16.9 6.2 35.6 33.2

67
VXS VORTEX submersible pumps
for sewage water

VORTEX stainless steel


submersible pumps for professional
use, particularly reliable with
generous motor specification and
hard-faced mechanical seal.
The proven VORTEX system allows
the clearing of dirty water
containing suspended solids.

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 105gpm • DELIVERY BODY: stainless steel AISI 304, with threaded port
Head up to 49 ft • MOTOR CASING AND BASE: stainless steel AISI 304.
LIMITS OF USE • IMPELLER: stainless steel AISI 304.

Depth up to 15 ft
• MOTOR SHAFT: stainless steel AISI 316.

Liquid temperature up to 104°f


• DOUBLE SEAL: mechanical seal silicon carbide - NBR - stainless
steel AISI 316, with oil barrier chamber and inner lip seal to protect the seal
Passage of suspended solid bodies up to 2”
in the event of dry running.
For continuous duty: minimum immersion 11” from pump base.
• MOTOR: submersible asynchronous for continuous duty.
VXS: single-phase 115V or 230V - 60 Hz with capacitor and `
thermal overload protector .
CONSTRUCTION AND SAFETY STANDARDS
VXS: three-phase 230V - 60 Hz.
EN 60 335-1 EN 60034-1 • INSULATION: class F. • PROTECTION: IP 68.
IEC 335-1 IEC 34-1
CEI 61-150 CEI 2-3
STANDARD FEATURES:

INSTALLATION AND USE VX


VXSS (single-phase) Flow switch.
THEY ARE RECOMMENDED FOR DRAINING WASTE WATER IN Neoprene power cable “H07 RN-F”
THE DOMESTIC, CIVIL AND INDUSTRIAL SECTORS, IN length 15 ft
APPLICATIONS WHERE THE WATER CONTAINS SUSPENDED
SOLIDS WITH DIMENSIONS UP TO Ø 2 plg. THEIR USE IS VX
VXSS (three-phase) Neoprene power cable “H07 RN-F”
RECOMMENDED FOR DRYING FLOODED AREAS SUCH AS length 15 ft
CELLARS, UNDERGROUND CAR PARKS, CAR WASHING AREAS
AND FOR EMPTYING CESSPITS or SEWAGE DISPOSAL.
THESE PUMPS ARE OUTSTANDING IN THEIR RELIABILITY IN OPTIONS ON REQUEST
FIXED INSTALLATIONS WITH AUTOMATIC OPERATION. ⇒ 30 ft power cable.
N.B. required for outdoor use to comply with standard EN 60335-2-41
GUARANTEE 2 YEARS subject to our general terms of sale. ⇒ single-phase pumps without float switch
⇒ other voltages or frequency 50 Hz

68
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Flow Rate QQ

MODEL FLOW RATE GPM 0 13 26 39 52 66 79 92 105


HP
1 PH 3 PH FLOW RATE l/min 0 50 100 150 200 250 300 350 400
VXSH 05 VXSH 05 0.5 28 25 21 17 12 7
VXSH 07 VXSH 07 0.7 33 31 28 24 19 13 7
H Feet
VXS 05 VXS 05 0.5 20 18 16 14 12 9 7 3
VXS 07 VXS 07 0.7 25 23 21 19 16 13 10 8 5

DIMENSIONS AND WEIGHT

Typical single-phase installation


a
p minimum
h

e
DN

h1

b minimum
d

MODEL DISCH Passage of DIMENSIONS INCHES LBS


1 PH 3 PH DN Solid bodies a b h h1 d e p min 1~ 3~
VXSH 05 VXSH 05 21.4
1 1/2" 1 1/2" 4.3 15.0 3.4 1.6
VXSH 07 VXSH 07 21.2 20.6
6.5 Adjustable 19.7 19.7
VXS 05 VXS 05 28.3
2" 2" 4.6 16.1 4.3 2.2
VXS 07 VXS 07 23.6 21.4

69
VXCH-M VORTEX submersible pumps
for sewage water

VORTEX submersible pumps


made of cast iron,
particularly robust and
reliable, ideal for fixed
installations. The proven
VORTEX system allows the
clearing of dirty water
containing suspended solids.

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 132 gpm • PUMP BODY: cast iron, with threaded port
Head up to 49 ft • MOTOR CASING AND BASE: cast iron.
• IMPELLER: stainless steel AISI 304.
LIMITS OF USE • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
Depth up to 30 ft • DOUBLE SEAL: mechanical seal silicon carbide - NBR, with oil barrier
Liquid temperature up to 104°f chamber and inner lip seal to protect the seal in the event of dry running.
Passage of solid bodies 1 1/4” • MOTOR: submersible asynchronous for continuous duty.
VXCH-M: single-phase 115V or 230 V - 60 Hz with thermal overload protector.
Passage of solid bodies 1 3/4”
VXCH-M: three-phase 230V - 60 Hz.
For continuous duty: minimum immersion 11” from pump base
• INSULATION: class F. • PROTECTION: IP 68.

CONSTRUCTION AND SAFETY STANDARDS


STANDARD FEATURES:
EN 60 335-1 EN 60034-1
IEC 335-1 IEC 34-1 VXCH-M (single-phase) Float switch.
CEI 61-150 CEI 2-3 Neoprene power cable “H07 RN-F”
length 30 ft
Control box with capacitor (Protection IP 64).
INSTALLATION AND USE
VXCH-M (three-phase) Neoprene power cable “H07 RN-F”
THE PUMPS IN THE VXC SERIES ARE MADE OF EXCEPTIONALLY
length 30 ft
ROBUST HEAVY-GAUGE CAST IRON, RESISTANT TO ABRASION
AND ARE EQUIPED WITH A VORTEX TYPE IMPELLER. THEY ARE
RECOMMENDED FOR DRAINING WASTE WATER CONTAINING
OPTIONS ON REQUEST
SUSPENDED SOLID BODIES, SEWAGE AND WATER MIXED WITH
MUD. ⇒ control box for three-phase pumps 1 Hp
⇒ single-phase pumps without float switch
GUARANTEE 2 YEARS subject to our general terms of sale. ⇒ other voltages or frequency 50 Hz

70
CURVES AND PERFORMANCE DATA

Head H (meters)
Head H (feet)

Flow Rate Q

MODEL FLOW RATE GPM 0 13 26 39 52 66 79 92 105 119 132


HP
1 PH 3 PH FLOW RATE /min 0 50 100 150 200 250 300 350 400 450 500
VXCH 05 0.5 32 28 25 20 14 8
VXCH 07 VXCH 07 0.7 38 36 32 27 22 15 8
VXCH 10 VXCH 10 1 57 53 49 45 40 34 28 23 15 8
H Feet
VXCM 05 0.5 23 21 19 17 14 11 8 4
VXCM 07 VXCM 07 0.7 28 26 25 22 19 15 12 9 6
VXCM 10 VXCM 10 1 42 40 38 36 34 31 28 26 23 19 15

DIMENSIONS AND WEIGHT


Typical single-phase installation

SINGLE-PHASE CONTROL BOX


p minimum

DN
h
n

e
h1

m o
b c
d

minimum

MODEL DISCH Passage of DIMENSIONS INCHES LBS


1 PH 3 PH DN Solid bodies a b c h h1 m n o d e p min 1~ 3~
VXCH 05 37.6
4.1 3.5 5.4 13.8 4.8
VXCH 07 VXCH 07 1 1/2" 1 1/2" 1.6 41.3 37.8
VXCH 10 VXCH 10 3.6 5.6 14.6 5.2 46.2 43.8
3.2 7.9 2.6 Adjustable 19.7 19.7
VXCM 05 4.3 39.8
3.5 5.9 14.8 5.8
VXCM 07 VXCM 07 2" 2" 2.2 43.5 39.8
VXCM 10 VXCM 10 4.7 3.8 6.4 15.6 6.0 48.4 46.0

71
VXC-L VORTEX submersible pumps
for sewage water

VORTEX submersible pumps in


cast iron, particularly robust and
reliable, intended for continuous
heavy duty use in fixed
installations, in building services
and industry. Recommended for
sewage and waste water of all
types with solid impurities.

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 317 gpm • PUMP BODY, MOTOR CASING: cast iron.
Head up to 52 ft • IMPELLER: cast iron.
• BASE: stainless steel AISI 304.
LIMITS OF USE • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4057.
Depth up to 30 ft • DOUBLE SEAL: mechanical seal silicon carbide - widia -NBR, with oil
barrier chamber and inner lip seal to protect the seal in the event of dry running.
Liquid temperature up to 104°f
Passage of solid bodies max up to 3”
• MOTOR: submersible asynchronous, 2 pole, for continuous duty.
VXC-L: single-phase 230V - 60 Hz
For continuous duty: minimum immersion 16” from pump base Models up to 1.5 Hp have built in thermal protection
2 Hp single-phase versions have a thermal protector
CONSTRUCTION AND SAFETY STANDARDS provided in the winding for connection to the control box.
VXC-L: three-phase 230V - 60 Hz.
EN 60 335-1 EN 60034-1 -Thermal protectors are provided in the winding for connection
IEC 335-1 IEC 34-1 to the external control panel
CEI 61-150 CEI 2-3 • INSULATION: class F. • PROTECTION: IP 68.

STANDARD FEATURES:
INSTALLATION AND USE VXC-L (single-phase) Float switch.
VXC SERIES PUMPS ARE MADE OF EXCEPTIONALLY ROBUST 30 ft “H07 RN-F” submersible power cable
HEAVY-GAUGE CAST IRON, RESISTANT TO ABRASION AND 1 Hp to 1.5 Hp models are supplied with control box with capacitor
LONG-LASTING, AND HAVE A VORTEX TYPE IMPELLER. THEY and manual reset motor protector.
2 Hp models are supplied with control box type
ARE SUITABLE FOR SEWAGE, WASTE WATER AND SLUDGE,
QES 300 MONO.
INCLUDING WATER CONTAINING SOLIDS OR MUD. THEY ARE
VXC-L (three-phase) 30 ft “H07 RN-F” neoprene power cable
IDEAL FOR SEWAGE INSTALLATION, TUNNELS AND OTHER
EXCAVATIONS, UNDERGROUND CAR PARKS AND SIMILAR
APPLICATIONS. OPTIONS ON REQUEST
⇒ control box for three-phase pumps
GUARANTEE 2 YEARS subject to our general terms of sale. ⇒ dual voltage: 230/400 V - 60 Hz
⇒ single-phase versions without float switch
⇒ other voltages or frequency 50 Hz

72
CURVES AND PERFORMANCE DATA

Head H (meters)
Head H (feet)

Flow Rate Q

MODEL FLOW RATE GPM 0 26 52 79 92 105 132 158 185 211 224 238 264 291 317
HP
1 PH 3 PH FLOW RATE l/min 0 100 200 300 350 400 500 600 700 800 850 900 1000 1100 1200
VXCL 10 VXCL 10 1 37 34 31 26 23 21 14 6
VXCL 15 VXCL 15 1.5 42 39 36 31 29 26 21 14 6
VXCL 20 VXCL 20 2 52 49 45 42 40 37 32 26 19 10 6
H Feet
VXC 10 VXC 10 1 21 0 18 16 15 14 12 9 7 4 3
VXC 15 VXC 15 1.5 27 0 24 21 20 19 17 14 11 9 7 6 3
VXC 20 VXC 20 2 36 0 31 29 28 26 24 21 19 16 15 13 10 8 4

DIMENSIONS AND WEIGHT


Typical single-phase installation

SINGLE-PHASE CONTROL BOX

DN
h
n

p minimum

m o
h1

b c minimum
d

MODEL DISCH Passage of DIMENSIONS INCHES LBS


1 PH 3 PH DN Solid bodies a b c h h1 m n o d e p min 1~ 3~
VXCL 10 VXCL 10 73.5 68.5
19.3
VXCL 15 VXCL 15 2 1/2" 2 1/2" 6.4 5.3 8.3 7.4 2.9 76.9 73.5
VXCL 20 VXCL 20 19.7/19.3 89.9 76.9
3.1 7.8 3.3 Adjustable 31.4 31.4
VXC 10 VXC 10 85.9 80.8
20.8
VXC 15 VXC 15 3" 3" 7.1 5.9 9.4 9.0 3.3 90.1 85.9
VXC 20 VXC 20 19.7/19.3 103.8 90.8

73
MC DOUBLE-CHANNEL submersible pumps
for sewage water

DOUBLE-CHANNEL
submersible pumps for
professional use.
Particularly efficient
and reliable, with
generous motor
specification and hard-
faced mechanical seal.

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 211gpm • DELIVERY BODY: cast iron, with threaded port
Head up to 49 ft • MOTOR CASING: stainless steel AISI 304.
LIMITS OF USE • Base: stainless steel AISI 304.

Depth up to 15 ft
• IMPELLER: double-channel in stainless steel AISI 304.

Liquid temperature up to 104°f


• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.

Passage of suspended solid bodies up to 2”


• DOUBLE SEAL: mechanical seal silicon carbide - NBR, with oil barrier
chamber and inner lip seal to protect the seal in the event of dry running.
For continuous duty: minimum immersion 11” from pump base
• MOTOR: submersible asynchronous for continuous duty.
MC: single-phase 115V or 230V - 60 Hz with capacitor and
CONSTRUCTION AND SAFETY STANDARDS thermal overload protector.
MC: three-phase 230V - 60 Hz.
EN 60 335-1 EN 60034-1
IEC 335-1 IEC 34-1
• INSULATION: class F. • PROTECTION: IP 68.

CEI 61-150 CEI 2-3


STANDARD FEATURES:
INSTALLATION AND USE MC (single-phase) Float switch.
MC SUBMERSIBLE PUMPS ARE RECOMMENDED FOR DRAINING Neoprene power cable “H07 RN-F”
DIRTY WATER AND SEWAGE IN THE DOMESTIC AND CIVIL length 15 ft
SECTORS. THEY ARE EQUIPPED WITH A “DOUBLE-CHANNEL”
STAINLESS STEEL IMPELLER WHICH ALLOWS THE PUMPING OF MC (three-phase) Neoprene power cable “H07 RN-F”
LIQUIDS CONTAINING SUSPENDED SOLID BODIES WITH length 15 ft
DIMENSIONS UP TO Ø 2 plg AND SHORT FIBRES. THEY ARE
IDEAL FOR PUMPING DRAINAGE WATER, SEWAGE OR WASTE OPTIONS ON REQUEST
WATER FOR A SINGLE DWELLING, AND FOR CLEARING SUFACE
OR NUISANCE WATER, EVEN IF MUDDY. THESE PUMPS ARE
⇒ 30 ft power cable.
N.B. required for outdoor use to comply with standard EN 60335-2-41
OUTSTANDING IN THEIR RELIABILITY IN FIXED INSTALLATIONS
WITH AUTOMATIC OPERATION. ⇒ control box for three-phase pumps 1 Hp
⇒ single-phase pumps without float switch
GUARANTEE 2 YEARS subject to our general terms of sale. ⇒ other voltages or frequency 50 Hz

74
CURVES AND PERFORMANCE DATA

Head H (meters)
Head H (feet)

Flow Rate Q

MODEL FLOW RATE GPM 0 13 26 39 52 66 79 92 105 119 132 158 185 211
HP
1 PH 3 PH FLOW RATE l/min 0 50 100 150 200 250 300 350 400 450 500 600 700 800
MC 07 MC 07 0.7 39 35 32 29 26 22 19 16 13 10 7
H Feet
MC10 MC 10 1 49 46 43 40 38 34 32 29 26 23 20 15 9 3

DIMENSIONS AND WEIGHT

Typical single-phase installation

a
p minimum
h

DN
e
h1

b c minimum

MODEL DISCH Passage of DIMENSIONS INCHES LBS


1 PH 3 PH DN Solid bodies a b c h h1 d e p min 1~ 3~
MC 07 MC 07 43.3 35.4 59.1 161.4 60.2 21.7 31.6 29.4
2" 2" Adjustable 19.7 19.7
MC10 MC 10 47.2 14.6 64.2 169.3 62.2 25.6 36.5 31.6

75
MCS DOUBLE-CHANNEL submersible pumps
for sewage water

DOUBLE-CHANNEL
stainless steel submersible
pumps for professional
use. Particularly efficient
and reliable, with generous
motor specification and
hard-faced mechanical
seal.

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 210 gpm • DELIVERY BODY: stainless steel AISI 304, with threaded port
Head up to 49 ft • MOTOR CASING AND BASE: stainless steel AISI 304.

LIMITS OF USE
• IMPELLER: double-channel, in stainless steel AISI 304.
• MOTOR SHAFT: stainless steel AISI 316.
Depth up to 15 ft • DOUBLE SEAL: mechanical seal silicon carbide - NBR - stainless steel
Liquid temperature up to 104°f AISI 316, with oil barrier chamber and inner lip seal to protect the seal in
Passage of suspended solid bodies up to 2” the event of dry running.
For continuous duty: minimum immersion 11” from pump base • MOTOR: submersible asynchronous for continuous duty.
MCS: single-phase 115V or 230V - 60 Hz with capacitor and
thermal overload protector.
CONSTRUCTION AND SAFETY STANDARDS
MCS: three-phase 230V - 60 Hz.
EN 60 335-1 EN 60034-1 • INSULATCION: class F. • PROTECTION: IP 68.
IEC 335-1 IEC 34-1
CEI 61-150 CEI 2-3
STANDARD FEATURES:

MCS (single-phase) Float switch.


INSTALLATION AND USE
Neoprene power cable “H07 RN-F”
MC-I SUBMERSIBLE PUMPS ARE RECOMMENDED FOR length 15 ft
DRAINING DIRTY WATER AND SEWAGE IN THE DOMESTIC AND
CIVIL SECTORS. THEY ARE EQUIPPED WITH A “DOUBLE- MCS (three-phase) Neoprene power cable “H07 RN-F”
CHANNEL” STAINLESS STEEL IMPELLER WHICH ALLOWS THE
length 15 ft
PUMPING OF LIQUIDS CONTAINING SUSPENDED SOLID BODIES
WITH DIMENSIONS UP TO 2 plg. AND SHORT FIBRES. THEY ARE
IDEAL FOR PUMPING DRAINAGE WATER, SEWAGE OR WASTE
WATER FOR A SINGLE DWELLING, AND FOR CLEARING OPTIONS ON REQUEST
SURFACE OR NUISANCE WATER, EVEN IF MUDDY. THESE PUMPS ⇒ 30 ft power cable.
ARE OUTSTANDING IN THEIR RELIABILITY IN FIXED N.B. required for outdoor use to comply with standard EN 60335-2-41
INSTALLATIONS WITH AUTOMATIC OPERATION. ⇒ control box for three-phase pumps 1 Hp
⇒ single-phase pumps without float switch
GUARANTEE 2 YEARS subject to our general terms of sale. ⇒ other voltages or frequency 50 Hz

76
CURVES AND PERFORMANCE DATA

Head H (meters)
Head H (feet)

Flow Rate Q

MODEL FLOW RATE GPM 0 13 26 39 52 66 79 92 105 119 132 158 185 211
HP
1 PH 3 PH FLOW RATE l/min 0 50 100 150 200 250 300 350 400 450 500 600 700 800
MCS 07 MCS 07 0.7 39 35 32 29 26 22 19 16 13 10 7
H Feet
MCS 10 1 49 46 43 40 38 34 32 29 26 23 20 15 9 3

DIMENSIONS AND WEIGHT

Typical single-phase installation


a
p minimum
h

e
DN

h1

b minimum
d

MODEL DISCH Passage of DIMENSIONS INCHES LBS


1 PH 3 PH DN Solid bodies a b h h1 d e p min 1~ 3~
MCS 07 MCS 07 22
2" 2" 4.6 6.5 16.1 4.3 2.2 Adjustable 19.6 19.68 28
MCS 10 28

77
MCM DOUBLE-CHANNEL submersible pumps
for sewage water

DOUBLE-CHANNEL cast
iron submersible pumps
for professional use.
Particularly efficient
and reliable, with
generous motor
specification and hard-
faced mechanical seal.

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 211 gpm
Head up to 49 ft
• PUMP BODY: cast iron, with threaded port
• MOTOR CASING AND BASE: cast iron.
LIMITS OF USE • IMPELLER: double-channel, in stainless steel AISI 304.
Depth up to 30 ft • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
Liquid temperature up to 104°f • DOUBLE SEAL: mechanical seal silicon carbide - NBR, with oil barrier
Passage of suspended solid bodies up to 1 3/4” chamber and inner lip seal to protect the seal in the event of dry running.
For continuous duty: minimum immersion 11” from pump base • MOTOR: submersible asynchronous for continuous duty.
MCM: single-phase 115V or 230V - 60 Hz with thermal overload protector.
CONSTRUCTION AND SAFETY STANDARDS MCM: three-phase 230V - 60 Hz.

EN 60 335-1 EN 60034-1
• INSULATION: class F. • PROTECTION: IP 68.

IEC 335-1 IEC 34-1


CEI 61-150 CEI 2-3 STANDARD FEATURES:

M CCM
M M (single-phase) Float switch.
INSTALLATION AND USE Neoprene power cable “H07 RN-F”
MC
THE PUMPS IN THE M CM
M SERIES ARE MADE OF EXCEPTIONALLY length 30 ft
ROBUST HEAVY-GAUGE CAST IRON, RESISTANT TO ABRASION Control box with condenser.
AND LONG-LASTING. THEY ARE EQUIPPED WITH A DOUBLE-
CHANNEL IMPELLER WHICH ALLOWS THE DRAINAGE OF M CCM
M M (three-phase) Neoprene power cable “H07 RN-F”
LIQUIDS CONTAINING SUSPENDED SOLID BODIES WITH length 30 ft
DIMENSIONS UP TO Ø 1 3/4” AND SHORT FIBRES. THEY ARE
IDEAL FOR PUMPING DRAINAGE WATER AND SEWAGE, WASTE
WATER INCLUDING WATER MIXED WITH MUD, GROUNDWATER OPTIONS ON REQUEST
AND SURFACE WATER IN APPLICATIONS SUCH AS: ⇒ control box for three-phase pumps 1 Hp
CONDOMINIUMS, MULTI-STOREY AND UNDERGROUND CAR ⇒ single-phase pumps without float switch
PARKS, WASHING AREAS AND INDUSTRY.
⇒ other voltages or frequency 50 Hz
GUARANTEE 2 YEARS subject to our general terms of sale.

78
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 13 26 39 52 66 79 92 105 119 132 158 185 211
HP
1 PH 3 PH FLOW RATE l/min 0 50 100 150 200 250 300 350 400 450 500 600 700 800
MCM 07 MCM 07 0.7 39 35 32 29 26 22 19 16 13 10 7
H Feet
MCM 10 MCM 10 1 49 46 43 40 38 34 32 29 26 23 20 15 9 3

DIMENSIONS AND WEIGHT

Typical single-phase installation

SINGLE-PHASE CONTROL BOX


p minimum

DN
h
n

e
h1

m o
b c
d

minimum

MODEL DISCH Passage of DIMENSIONS INCHES LBS


1 PH 3 PH DN Solid bodies a b c h h1 m n o d e p min 1~ 3~
MCM 07 MCM 07 4 3.5 5.9 14.8 5.8 43.9 40.4
2" 1 3/4" 3.1 7.8 2.5 2.1 Adjustable 19.6 19.6
MCM 10 MCM 10 4.7 3.8 6.4 15.6 6.0 48.8 46.4

79
MC-L
SINGLE-CHANNEL submersible pumps
for sewage water

SINGLE-CHANNEL submersible pumps


highly efficient and particularly
robust and reliable. Ideal for fixed
installations or for continuous heavy
duty use, recommended for sewage
and waste water with solid impurities
in building services or industrial
applications.

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 422 gpm • PUMP BODY, MOTOR CASING: cast iron.
Head up to 78 ft • IMPELLER: single-channel, in cast iron.
• BASE: stainless steel AISI 304.
LIMITS OF USE • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4057.
Depth up to 30 ft • DOUBLE SEAL: mechanical seal silicon carbide - widia - NBR,
with oil barrier chamber and inner lip seal to protect the seal in the
Liquid temperature up to 104°f
event of dry running.
Passage of solid bodies max up to 3”
• MOTOR: submersible asynchronous, 2 pole, for continuous duty.
For continuous duty: minimum immersion 16” from pump base MC-L: single-phase 230V - 60 Hz
Models up to 1.5 Hp have built in thermal protection
CONSTRUCTION AND SAFETY STANDARDS 2.0 Hp single-phase versions have a thermal protector
provided in the winding for connection to the control box.
EN 60 335-1 EN 60034-1 MC-L: three-phase 230V - 60 Hz.
IEC 335-1 IEC 34-1 - Thermal protectors are provided in the winding for
CEI 61-150 CEI 2-3 connection to the external control panel
• INSULATION: class F. • PROTECTION: IP 68.

INSTALLATION AND USE STANDARD FEATURES:


MC
M C --L
L SERIES PUMPS ARE MADE OF EXCEPTIONALLY ROBUST MC
M C--L
L (single-phase) Float switch.
30 ft “H07 RN-F” submersible power cable.
HEAVY GAUGE CAST IRON, ABRASION RESISTANT AND LONG-
1.0 to 1.5 Hp models are supplied with control box with capacitor
LASTING, WITH A SINGLE-CHANNEL IMPELLER WHICH CAN
and manual reset motor protector.
HANDLE LIQUIDS WITH SUSPENDED SOLIDS AND SHORT 2.2 Hp models are supplied with control box type QES 300 MONO.
FIBRES. THEY ARE iDEAL FOR SEWAGE, WASTE AND GROUND
WATER, EVEN WITH SOLIDS OR MUD, AND ARE THEREFORE MC
M C--L
L (three-phase) 30 ft “H07 RN-F” neoprene power cable

RECOMMENDED FOR BUILDING OR INDUSTRIAL EFFLUENT AND


DRAINAGE OF LARGE AREAS SUCH AS CAR PARKS.
OPTIONS ON REQUEST
GUARANTEE 2 YEARS subject to our general terms of sale. ⇒ control box for three-phase pumps
⇒ dual voltage: 230/440V -60 Hz
⇒ single-phase versions without float switch
⇒ other voltages or frequency 50 Hz

80
CURVES AND PERFORMANCE DATA

Head H (meters)
H Head H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 13 26 52 79 105 132 158 185 211 238 264 291 317 370 423
HP
1 PH 3 PH FLOW RATE l/min 0 50 100 200 300 400 500 600 700 800 900 1000 1100 1200 1400 1600
MCL 10 MCL 10 1 52 49 46 41 34 28 23 16 10 3
MCL 15 MCL 15 1.5 59 56 52 46 41 34 30 23 16 10 3
H Feet
MCL 20 MCL 20 2 79 75 72 66 59 52 46 39 33 26 20 13 7
MC 20 MC 20 2 43 41 39 38 36 33 31 29 27 25 22 20 17 16 10 7

DIMENSIONS AND WEIGHT

Typical single-phase installation

SINGLE-PHASE CONTROL BOX

DN
h
n

p minimum

m o
h1

b c minimum
d

MODEL DISCH Passage of DIMENSIONS INCHES LBS


1 PH 3 PH DN Solid bodies a b c h h1 m n o d e p min 1~ 3~
MCL 10 MCL 10 75.1 70.3
19.3
MCL 15 MCL 15 2 1/2" 2" 6 5 8 7 3 78.9 75.1
3 8 3 Adjustable 31 31
MCL 20 MCL 20 19.7/19.3 92.2 79.1
MC 20 MC 20 3" 3" 28.2 33.8 21.5 19.7/19.3 9.5 3.34 106.1 93.0

81
4SK 4" submersible pump with peripheral impeller

Stainless steel submersible pump with


peripheral impeller and anti-seize system.
Standard version includes 30 feet power cable
and integral capacitor for ease of installation.

RANGE OF PERFORMANCE GUARANTEE 2 YEARS subject to our general terms of sale.


Flow rate up to 13 gpm
Head up to 223 ft CONSTRUCTION CHARACTERISTICS

LIMITS OF USE
• DELIVERY BODY: stainless steel AISI 304.
• IMPELLER HOUSING WITH PATENTED DOUBLE ANTI-SEIZE
Submersion depth up to 131 ft INSERTS.
Liquid temperature up to + 104°F • IMPELLER: brass, type with radial peripheral vanes.
• MOTOR JACKET: stainless steel AISI 304.
CONSTRUCTION AND SAFETY STANDARDS • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
EN 60 335-1 EN 60034-1 • MOTOR: asynchronous, dry rewindable stator, for continuous duty
IEC 335-1 IEC 34-1 4SK: single-phase 230 V - 60 Hz.
CEI 61-150 CEI 2-3 • INSULATION: class F. • PROTEZIONE: IP 68.
• MECHANICAL SEAL: ceramic - graphite - NBR.

INSTALLATION AND USE STANDARD FEATURES:

It is recommended for pumping clean water without abrasive particles


and liquids that are chemically non aggressive to the materials from
4 SKm
4 SK m Thermal overload protector.
Internal capacitor
which the pump is made. COMPACT AND ECONOMICAL, IT IS
Flat type 30 ft power cable.
RECOMMENDED FOR RESIDENTIAL APPLICATIONS INCLUDING
WATER SUPPLIES AND IRRIGATION.
OPTIONS ON REQUEST
⇒ 60 t power cable
⇒ other voltages or frequency 50 Hz

82
CURVES AND PERFORMANCE DATA

H (meters)
H (feet)
Head H

Head H
Q
Flow Rate Q

DEEPPTTH
D H TTO
OWWA
ATTEER
R IIN
N FFEEEETT//R
RAATTIIN
NGGSS IIN
NGGPPM
M
MO
MODDEELL HPP
H PSSII
P
200
2 4400 6600 8800 1 0000
1 122 00
1 114400
0 11 10.5 9 8 6 5
20 10 9 7 6.2 5 3
4SK 07
0.70 30 8 7 6 5
40 7 5 4
Shut -off PSI 117 108 100 91 82 44 36

DIMENSIONS AND WEIGHT


DN Typical Installation

Connection point for safety cable


h

The 4SK pump may be installed in


boreholes with a diameter not less
than 4”. The electropump is
lowered into the borehole by
means of the delivery pipe to such
a depth as to guarantee its
complete immersion (min. 19”
and at least one meter from the
bottom). Its good practice to
secure the pump by means of a
stainless steel or nylon cable,
connected to the anchoring points
Ø
on the delivery body.

MODEL DISCH DIMENSIONS INCHES LBS


1 PH DN1 Ø h 1~
4SK 07 1" 3.9 19.6 29

83
SUMO 18G
multi-stage submersible pumps

The best combination of


performance, reliability
and quiet running,
robust and easy to use.

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 23 gpm • OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304
Head up to 348 ft • IMPELLERS AND DIFFUSERS: technopolymer.
• DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings.
LIMITS OF USE • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
Liquid temperature up to 104°f • DOUBLE SEAL: mechanical seal silicon carbide-NBR, with oil barrier
Submersion depth up to 65 ft chamber and inner lip seal to protect the seal in the event of dry running.
• SCREWS AND FILTER: stainless steel AISI 304.
• MOTOR: asynchronous for continuous duty.
SUMO 18G: single-phase 230V - 60 Hz with thermal overload
CONSTRUCTION AND SAFETY STANDARDS protector built into windings below 1.5 Hp. The 2 Hp
EN 60 335-1 EN 60034-1 motor has an external overload protector (with
IEC 335-1 IEC 34-1 manual reset) incorporated into the control box.
SUMO 18G: three-phase 230V - 60 Hz.
CEI 61-150 CEI 2-3
• INSULATION: class F. • PROTECTION: IP 68.

STANDARD FEATURES:
INSTALLATION AND USE
SU
S UM
MO
O 1
18
8 G
G (single-phase) control box with capacitor
THEIR HIGH EFFICIENCY AND RELIABILITY MAKE THEM 70 ft power cable type “H07 RN-F” with removable connector
SUITABLE FOR PUMPING CLEAN WATER IN DOMESTIC, CIVIL
AND AGRICULTURAL APPLICATIONS, FOR DISTRIBUTING WATER SU
S UM
MO
O 1
18
8 G
G (three-phase) 70 ft power cable type
IN COMBINATION WITH PRESSURE SETS, FOR IRRIGATING “H07 RN-F” with removable connector.
GARDENS, BOOSTING PRESSURE, ETC.

GUARANTEE 2 YEARS subject to our general terms of sale. OPTIONS ON REQUEST


⇒ economy version 30 ft power cable and capacitor, (without control box)
⇒ single-phase pumps with external float switch (SUMO 18G...- GE)
⇒ other voltages or frequency 50 Hz

84
CURVES AND PERFORMANCE DATA

Head H (meters)
Head H (feet)

Flow Rate Q

MODEL FLOW RATE GPM 0 2 5 7 10 11 13 14 15 17 18 19 21 22 23


HP
1 PH 3 PH FLOW RATE l/min 0 10 20 30 40 45 50 55 60 65 70 75 80 85 90
SUMO18G 05 SUMO18G 05 0.5 125 120 115 108 102 97 92 87 82 76 69 62 56 49 39
SUMO18G 07 SUMO18G 07 0.7 177 174 171 164 158 153 148 141 138 130 123 115 108 99 92
SUMO18G 10 SUMO18G 10 1.0 223 218 210 204 192 186 181 172 164 158 151 141 135 123 115
H Feet
SUMO18G 15 SUMO18G 15 1.5 283 276 269 256 243 237 230 220 210 200 191 177 164 151 138
SUMO18G 20 SUMO18G 20 2.0 329 319 306 289 273 263 253 240 230 217 207 194 179 164 151
SUMO18GH 20 SUMO18GH 20 2.0 348 340 329 315 299 289 279 269 260 243 233 214 204 184 164

DIMENSIONS AND WEIGHT

Single-phase with float switch Single-phase with control box


DN
DN
Attachment point for safety cable
Attachment point for safety cable

SINGLE-PHASE CONTROL BOX


h

h
b

a c

Ø Ø

MODEL DISCHARGE DIMENSIONS INCHES LBS


1 PH 3 PH DN N° STAGES Ø h (1~) h (3~) a b c 1~ 3~
SUMO18G 05 - 15.1 26.3
3 15.1
SUMO18G 07 SUMO18G 07 17.0 28.7 25.4
1" 5.3
SUMO18G 10 SUMO18G 10 4 18.0 36.5 33.2
18.0
- SUMO18G 15 5 3.1 7.8 2.5 37.6
18.9
SUMO18G 15 - 4 20.1 52.2
SUMO18G 20 SUMO18G 20 1 1/4" 5 6.0 21.3 21.3 54.1 50.4
SUMO18GH 20 SUMO18GH 20 5 23.1 21.3 64.5 51.9

85
SUMO 25G
multi-stage submersible pumps

The perfect combination


of performance, reliability
and quiet running, robust
and easy to use.

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 34 gpm
Head up to 296 ft • OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304
• IMPELLERS AND DIFFUSERS: technopolymer.
LIMITS OF USE • DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings.
Liquid temperature up to 104°f • MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
Submersion depth up to 65 ft
• DOUBLE SEAL: mechanical seal silicon carbide-NBR, with oil barrier
chamber and inner lip seal to protect the seal in the event of dry running.
• SCREWS AND FILTER: stainless steel AISI 304.
CONSTRUCTION AND SAFETY STANDARDS • MOTOR: asynchronous for continuous duty.
SUMO 25G: single-phase 230V - 60 Hz with thermal overload
EN 60 335-1 EN 60034-1 protector built into windings below 1.5 Hp. The 2 Hp
IEC 335-1 IEC 34-1 motor has an external overload protector (with manual
CEI 61-150 CEI 2-3 reset) incorporated into the control box.
SUMO 25G: three-phase 230V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 68.
INSTALLATION AND USE
STANDARD FEATURES:
THEIR HIGH EFFICIENCY AND RELIABILITY MAKE THEM
SUITABLE FOR PUMPING CLEAN WATER IN COMMERCIAL, CIVIL SU
S UM
MO
O 2
25
5G
G (single-phase) Control box with capacitor

AND AGRICULTURAL APPLICATIONS, FOR DISTRIBUTING WATER 70 ft power cable type “H07 RN-F” with removable
IN COMBINATION WITH PRESSURE SETS, FOR IRRIGATING connector and Schuko plug.
GARDENS, BOOSTING PRESSURE, ETC. SU
S UM
MO
O 2
25
5G
G (three-phase) 70 ft power cable type

“H07 RN-F” with removable connector.


GUARANTEE 2 YEARS subject to our general terms of sale.

OPTIONS ON REQUEST
⇒ economy version 30 ft power cable and capacitor, (without control box)
⇒ single-phase pumps with external float switch (SUMO 25G...- GE)
⇒ other voltages or frequency 50 Hz

86
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Flow Rate Q Q

MODEL FLOW RATE GPM 0 2 5 7 10 13 15 18 21 23 26 29 31 34


HP
1 PH 3 PH FLOW RATE l/min 0 10 20 30 40 50 60 70 80 90 100 110 120 130
SUMO25G 05 SUMO25G 05 0.5 105 102 99 94 89 82 76 69 59 49 41 30 20 10
SUMO25G 07 SUMO25G 07 0.7 145 143 141 138 133 128 122 115 105 95 85 76 62 49
SUMO25G 10 SUMO25G 10 1.0 187 186 184 181 177 171 161 151 141 128 118 105 89 72
H Feet
SUMO25G 15 SUMO25G 15 1.5 223 220 217 210 204 195 187 176 164 151 135 122 105 89
SUMO25G 20 SUMO25G 20 2.0 263 260 253 246 240 233 223 214 204 191 177 161 145 125
SUMO25GH 20 SUMO25GH 20 2.0 296 292 289 283 276 269 263 253 246 237 223 210 195 177

DIMENSIONS AND WEIGHT


Single-phase with float switch Single-phase with control box
DN DN

Attachment point for safety cable


Attachment point for safety cable

SINGLE-PHASE CONTROL BOX


h
h

a c

Ø Ø
MODEL DISCHARGE DIMENSIONS INCHES LBS
1 PH 3 PH DN N° STAGES Ø h (1~) h (3~) a b c 1~ 3~
SUMO25G 05 - 15.1 26.3
3 15.1
SUMO25G 07 SUMO25G 07 17.0 28.7 25.4
1" 5.3
SUMO25G 10 SUMO25G 10 4 18.0 36.5 33.2
18.0
- SUMO25G 15 5 3.1 7.8 2.5 37.6
18.9
SUMO25G 15 - 4 20.1 52.2
SUMO25G 20 SUMO25G 20 1 1/4" 5 6.3 21.3 21.3 54.1 50.4
SUMO25GH 20 SUMO25GH 20 4 21.9 20.1 62.5 49.9

87
4BLOCK
4" monoblock submersible pumps

4” monoblock submersible pumps designed as


a more inexpensive alternative to traditional
borehole pumps without loss of performance
and reliability. Supplied with integral capacitor
and 65 ft power cable for ease of installation.

RANGE OF PERFORMANCE CONSTRUCTION CHARACTERISTICS


Flow rate up to 40 gpm • DELIVERY BODY: stainless steel AISI 304 with threaded port.
Head up to 442 ft • CASE: stainless steel AISI 304.
• IMPELLERS AND DIFFUSERS: technopolymer.
LIMITS OF USE • DIFFUSER HOUSING: stainless steel AISI 304.
Liquid temperature up to +86°F • PUMP SHAFT: stainless steel AISI 304.
Submersion depth up to 131 feet • PUMP BEARINGS: housing in special technopolymer with stainless
steel AISI 316 shaft bushes, chrome oxide coated to resist sand.
• DRIVE COUPLING: stainless steel AISI 316L.
• SCREWS AND CABLE COVER: stainless steel AISI 304.
CONSTRUCTION AND SAFETY STANDARDS • MOTOR SHAFT: stainless steel AISI 316
EN 60 335-1 EN 60034-1 (EN 10088-3 - 1.4104 up to 0.7 HP).
IEC 335-1 IEC 34-1 • MOTOR: submersible for continuous duty (dry rewindable).
4BLOCK: single-phase 230 V - 60 Hz.
CEI 61-150 CEI 2-3
4BLOCK: three-phase 230 V - 60 Hz.
• INSULATION: class F. • PROTECTION: IP 68.
• DOUBLE SEAL: mechanical seal ceramic - graphite - NBR with oil barrier
INSTALLATION AND USE chamber and inner lip seal to protect the seal in the event of dry running.
THEY ARE RECOMMENDED FOR PUMPING CLEAN WATER DUE
TO THEIR HIGH EFFICIENCY AND RELIABILITY, THEY ARE STANDARD FEATURES:
RECOMMENDED FOR DOMESTIC WATER SUPPLIES AS PART OF
4BLOCK (single-phase) Motor thermal protection built into the
A PRESSURE SET, OR FOR IRRIGATION.
winding. Internal capacitor.
GUARANTEE 2 YEARS subject to our general terms of sale. 65 ft flat power cable.

4BLOCK (three-phase) 65 ft flat power cable.

OPTIONS ON REQUEST
⇒ 100 ft power cable
⇒ other voltages or frequency 50 Hz

88
CURVES AND PERFORMANCE DATA

Head H (meters)
Head H (feet)

Flow Rate Q

89
CURVES AND PERFORMANCE DATA

Head H (meters)
H Head H (feet)

H
Flow Rate Q Q

DEPTH TO WATER IN FEET/RATINGS IN GPM


MODEL HP PSI
20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 340 380 420 460
0 18 17 16 15 14 12 11 9 7
20 17 16 15 14 12 11 10 7 5
30 17 16 15 14 12 11 10 8 4
4BLOCK13G07 0.70
40 17 16 15 14 12 11 10 8 4
50 16 15 14 12 10 9 6 2
60 15 14 12 11 9 6 2
Shut -off PSI 117 108 100 91 82 74 65 56 48 39 30 22 13
0 12 18 17 16 16 15 14 13 12 10 9 3.2
20 18 17 16 15 14 13 12 11 10 8 6 2
30 18 17 16 15 14 13 12 11 10 8 6 2
4BLOCK13G10 1
40 18 17 16 15 14 13 12 11 10 8 6 2
50 17 16 15 14 14 13 12 10 9 7 3
60 17 16 15 14 13 11 11 9 7 3
Shut -off PSI 145 136 128 119 110 102 93 84 76 67 58 50 41 32 24 9
0 18 18 17 16 16 15 14 14 12 10 8 4
20 18 18 17 17 16 15 15 14 13 13 12 10 7 3
30 18 18 17 17 16 15 15 14 13 13 12 11 9 6 2
4BLOCK13G15 1.5
40 18 18 17 16 16 16 15 14 13 13 12 11 10 7 2
50 18 18 17 16 16 15 15 14 13 12 11 10 9 8 4
60 18 18 17 16 16 15 14 14 13 13 11 10 9 8 5
Shut -off PSI 199 190 182 173 165 156 147 139 130 121 113 104 95 87 78 61 43 26 9

90
CURVES AND PERFORMANCE DATA

Head H (meters)
HHead H (feet)

H
Flow Rate QQ

DEPTH TO WATER IN FEET/RATINGS IN GPM


MODEL HP PSI
20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 340 380 420 460 500
0 32 30 26 23 18 14 6
20 31 28 24 21 15 10
30 28 24 21 15 10
4BLOCK25G 07 0.75
40 24 21 16 9
50 18 14 6
60 13 5
Shut-off PSI 71 63 54 45 37 28 19
0 32 29 26 22 18 14 8
20 27 24 20 15 10 4
30 27 23 20 15 10 5
4BLOCK25G 10 1
40 27 23 20 15 11 4
50 22 18 14 8
60 18 14 8
Shut-off PSI 84 76 67 58 50 41 32 24 15
0 31 30 28 25 23 20 17 14 9 4
20 32 30 29 26 24 22 19 15 12
30 32 31 28 27 24 22 19 15 12 7
4BLOCK25G 15 1.5
40 32 31 29 27 24 22 19 15 12 7
50 30 28 25 23 20 17 14 9 4
60 28 25 23 20 17 14 10 4
Shut-off PSI 126 117 108 100 91 82 74 65 56 48 39 30 22
0 32 31 29 28 26 24 22 21 18 14 6
20 29 28 27 25 23 22 20 17 14 12 4
30 30 28 27 25 24 21 20 17 14 12
4BLOCK25G 20 2
40 29 28 27 25 23 21 20 17 14 11
50 32 31 29 27 26 24 22 21 19 14 6
60 30 29 27 26 25 22 21 19 13 6
Shut-off PSI 165 156 147 139 130 121 113 104 95 87 78 69 61 52 43 26

91
CURVES AND PERFORMANCE DATA

Head H (meters)
H Head H (feet)

H
Flow Rate Q Q

DEPTH TO WATER IN FEET/RATINGS IN GPM


MODEL HP PSI
20 40 60 80 100 120 140 160 180 200 220 240
0 47 40 31 16
20 43 35 23 10
30 34 23 9
4BLOCK33G 07 0.75
40 24 10
50
60
Shut-off PSI 50 41 32 24 15
0 45 40 34 24
20 48 43 37 29 15
30 42 38 29 16
4BLOCK33G 10 1
40 37 28 16
50 25 6
60
Shut-off PSI 61 52 43 35 26 17 9
0 48 44 40 34 27 17
20 46 41 36 30 21 16
30 46 40 37 29 22 17
4BLOCK33G 15 1.5
40 41 36 31 22 16
50 34 26 17
60 27 18
Shut-off PSI 76 67 58 50 41 32 24 17 9
0 46 43 39 35 31 25 17
20 41 37 33 28 22 11
30 42 36 33 27 21 12
4BLOCK33G 20 2
40 44 41 36 32 29 22 11
50 43 39 35 31 26 18
60 28 24 32 26 19
Shut-off PSI 104 95 87 78 69 61 52 43 35 26 17 9

92
DIMENSIONS AND WEIGHT
Ø Typical Installation
DN

Connection point for safety cable

STATIC LEVEL

DYNAMIC LEVEL
h

min 1 meter

MODEL DISCH DIMENSIONS INCHES LBS


1 PH 3 PH DN No Stages Ø h 1 PH 3 PH
4BLOCK13G 07 4BLOCK13G 07 9 693/668 23 20
4BLOCK13G 10 4BLOCK13G 10 11 774/749 26 23
4BLOCK13G 15 4BLOCK13G 15 15 987/927 33 28
4BLOCK25G 07 4BLOCK25G 07 6 663/638 22 19
4BLOCK25G 10 4BLOCK25G 10 7 732/707 25 23
4BLOCK25G 15 4BLOCK25G 15 1 1/4" 10 3.92 901/841 32 26
4BLOCK25G 20 13 */1014 33
4BLOCK33G 07 4BLOCK33G 07 4 629/604 21 19
4BLOCK33G 10 4BLOCK33G 10 5 714/689 25 23
4BLOCK33G 15 4BLOCK33G 15 6 864/804 31 25
4BLOCK33G 20 8 */1008 34

93

Potrebbero piacerti anche