Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
682
SWEP
COMPACT BRAZED HEAT EXCHANGERS (CBE’s)
CONDENSERS
REFRIGERANT
PART NO MODEL TONS WIDTH (in) LENGTH (in) DEPTH (in) IN (F1) OUT (F3) WATER-NPT NET
(F4 & F2) I.D. (in.) WEIGHT
SW10010-010 B8 CD 1/2 1/2 2.8 12.2 1.1 7/8 7/8 3/4 3.5
SW10010-016 B8 CD 3/4 3/4 2.8 12.2 1.6 7/8 7/8 3/4 4.5
SW10010-016 B8 CD 1 1 2.8 12.2 1.6 7/8 7/8 3/4 4.5
SW10010-020 B8 CD 1-1/2 1-1/2 2.8 12.2 1.9 7/8 7/8 3/4 5.1
SW10010-024 B8 CD 2 2 2.8 12.2 2.3 7/8 7/8 3/4 8.5
SW10010-030 B8 CD 2-1/2 2-1/2 2.8 12.2 2.8 7/8 7/8 3/4 9.9
SW10039-020 B15 CD 3/4 3 2.8 18.3 1.9 7/8 7/8 3/4 7.5
SW10039-026 B25 E 3-1/2 3/12 2.8 18.3 2.5 7/8 7/8 3/4 8.9
SW10039-026 B15 CD 4 4 2.8 18.3 2.5 7/8 7/8 3/4 8.9
SW10039-040 B15 CD 5 5 2.8 18.3 3.7 7/8 7/8 3/4 12.2
SW10961-030 B27 CD 7-1/2 7-1/2 4.7 20.7 2.9 1-3/8 1-3/8 1-1/4 19.4
SW10961-040 B27 CD 10 10 4.7 20.7 3.9 1-3/8 1-3/8 1-1/4 24.3
SW10961-050 B27 CD 12-1/2 12-1/2 4.7 20.7 4.8 1-3/8 1-3/8 1-1/4 29.3
SW10961-060 B27 CD 15 15 4.7 20.7 5.7 1-3/8 1-3/8 1-1/4 34.3
SW10175-040 B45 CD 20 20 9.5 20.6 4.1 1-5/8 1-5/8 1-1/2 49.8
SW11751-050 B57 CD 30 30 12.0 27.3 5.2 2-5/8 2-5/8 2-1/2 77.6
SW11751-070 B57 CD 40 40 12.0 27.3 7.1 2-5/8 2-5/8 2-1/2 96.3
SW11751-080 B57 CD 50 50 12.0 27.3 8.0 2-5/8 2-5/8 2-1/2 105.7
SWEP
SW11751-100 B57 CD 60 60 12.0 27.3 7.1 2-5/8 2-5/8 2-1/2 124.4
SW11751-120 B57 CD 70 70 12.0 27.3 11.6 2-5/8 2-5/8 2-1/2 143.1
SW11751-140 B57 CD 80 80 12.0 27.3 13.5 2-5/8 2-5/8 2-1/2 161.8
SW11751-160 B57 CD 90 90 12.0 27.3 15.3 2-5/8 2-5/8 2-1/2 180.5
SW11751-180 B57 CD 100 100 12.0 27.3 17.1 2-5/8 2-5/8 2-1/2 199.2
SW11751-200 B57 CD 110 110 12.0 27.3 18.9 2-5/8 2-5/8 2-1/2 217.9
SW11751-220 B57 CD 120 120 12.0 27.3 20.8 2-5/8 2-5/8 2-1/2 236.6
NOTES:
Nominal Tons - 15,000 Btu/h.
Conditions — 85°F EWT, 105°F Condensing Temp, 3.5°F Sub-Cooling, 3 Gpm per ton, R-22.
For other conditions call the Totaline Commercial Refrigeration Hotline.
Various connection executions are possible, please get in touch with RCD Commercial Refrigeration.
SUBCOOLERS ECONOMIZERS
REFRIGERANT
PART NO MODEL TONS WIDTH (in) LENGTH (in) DEPTH (in) In (F3) Out (F1) WATER-NPT NET
I.D. (in.) I.D. (in.) (F2 & F4) I.D. (in.) WEIGHT
SW10014-016 B8 SE 2 2 2.80 12.20 1.60 7/8 7/8 7/8 4.50
SW10015-016 B10 SE 3 3 4.6 11.3 1.7 7/8 7/8 7/8 7.8
SW10015-026 B10 SE 5 5 4.6 11.3 2.6 7/8 1-1/8 1-1/8 10.5
SW11142-020 B27 SE 7 7 4.6 20.7 2.0 7/8 1-1/8 1-1/8 12.4
SW10863-026 B27 SE 10 10 4.6 20.7 2.6 7/8 1-3/8 1-3/8 17.4
SW10863-030 B27 SE 12 12 4.6 20.7 2.9 7/8 1-3/8 1-3/8 19.4
SW11730-036 B27 SE 14 14 4.6 20.7 3.5 7/8 1-5/8 1-5/8 22.3
SW11731-040 B27 SE 16 16 4.6 20.7 3.9 1-3/8 1-5/8 1-5/8 24.3
SW11733-026 B45 SE 18 18 9.5 20.7 2.8 1-3/8 1-5/8 2-1/8 36.6
SW11733-030 B48 SE 20 20 9.5 20.7 3.2 1-3/8 1-5/8 2-1/8 40.4
SW11733-034 B48 SE 22 22 9.5 20.7 3.6 1-3/8 1-5/8 2-1/8 44.1
SW11732-040 B48 SE 28 28 9.5 20.7 4.1 1-3/8 2-1/8 2-1/8 49.8
NOTES:
Nominal Tons - 12,000 Btu/h.
Liquid refrigerant subcooled from 110°F to 50°F, Evaporating Temp 35°F , Superheat 9°F, per Ton.
For other conditions run unit performance calculation on SSP.
Pressure drop across the liquid side of the subcoolers is less than 3.75 psi for all selections.
683