Reference Manual

MDS Intrepid ODU-C

Outdoor RF Unit
for use with Compatible MDS Intrepid IDUs

MDS 05-4992A01, Rev. A


MARCH 2010
Table of Contents
Chapter 1: Installation ................................................................................... 1-1
General................................................................................................................................ 1-1

Installation Components ................................................................................................... 1-2

1+0 Direct Mount Installation ............................................................................................ 1-3

1+1 Direct Mount Installation ............................................................................................ 1-5

1+0 Remote Mount Installation ......................................................................................... 1-8

1+1 Remote Mount Installation ....................................................................................... 1-10

Mediation Device (Antenna Mount) Losses................................................................... 1-13

Antenna Connection ........................................................................................................ 1-14

Direct Mount for Nokia FlexiHopper Antennas ............................................................. 1-15

ODU-C NSN Adapter Installation .................................................................................... 1-16

1500P ODU Antenna Adaptor.......................................................................................... 1-18

ODU-C to 1500P Interface Installation ........................................................................... 1-19

Packing.............................................................................................................................. 1-26

Transportation .................................................................................................................. 1-26

Inspection ......................................................................................................................... 1-26

Chapter 2: Acceptance & Commissioning Procedures.............................. 2-1


General................................................................................................................................ 2-1

Site Acceptance Procedure............................................................................................... 2-2

1+0 Commissioning Procedure ........................................................................................ 2-7

1+1 Commissioning Procedure ........................................................................................ 2-9

2+0 XPIC Commissioning Procedure............................................................................. 2-12

Intrepid ODU-C Commissioning Log ............................................................................. 2-15

Appendix A: Frequency Information............................................................A-1


General................................................................................................................................A-1

ODU Frequency Bands ......................................................................................................A-1

6-8 GHz Channels...............................................................................................................A-7


Safety Precautions & Declared Material

Fiber Optic Line Precautions

Before turning on the equipment, make sure that the fiber optic cable is intact and is
connected to the transmitter.
!
Do not attempt to adjust the laser drive current.
!
Do not use broken or non-terminated fiber optic cables/connectors or look
! straight at the laser beam.
ATTENTION: The laser beam is invisible!

The use of optical devices with the equipment will increase eye hazard.
!
CLASS 1 LASER PRODUCT
Complies with IEC 60 825-1:1993 + A1:1997 + A2:2001, and EN 60825-1:1994
+ A1:1996 + A2:2001

General Equipment Precautions

Use of controls, adjustments, or performing procedures other than those


! specified herein, may result in hazardous radiation exposure.

When working with an IDU, note the following risk of electric shock and
! energy hazard: Disconnecting one power supply disconnects only one power
supply module. To isolate the unit completely, disconnect all power supplies.

Machine noise information order - 3. GPSGV, the highest sound pressure


! level amounts to 70 dB (A) or less, in accordance with ISO EN 7779.
Safety Precautions & Declared Material (continued)

Static electricity may cause bodily harm, as well as harm to electronic components
inside the device.
Anyone responsible for the installation or maintenance of the IDU must use an
ESD Wrist Strap.
ESD protection measures must be observed when touching the IDU.
To prevent damage, before touching components inside the device, all electrostatic
must be discharged from both personnel and tools.

RoHS Compliance Declaration

电子信息产品有毒有害物质申明
Electronic Information Products Declaration of Hazardous/Toxic Substances

危害物质
Hazardous Substance
成分名称
六价铬 多溴二苯醚
Component 铅 汞 镉 多溴联苯
Hexavalent Polybrominated
Lead Mercury Cadmium Chromium (Cr Polybrominated Diphenyl Ethers
(Pb) (Hg) (Cd) VI) Biphenyls (PBB) (PBDE)
单板 / 电路模块
PCB/Circuit Comply Comply Comply Comply Comply Comply
Modules

结构件
Comply Comply Comply Comply Comply Comply
Mechanical Parts
电缆
Comply Comply Comply Comply Comply Comply
Cables
Chapter 1: Installation
General
This guide provides installation procedures for the MDS ODU-C (Outdoor Unit):

About the ODU-C


ODU-C is a state-of-the-art Radio Frequency Unit which is fully software configurable and supports a broad range
of capacities and interfaces. It supports low-to-high capacities for traditional voice and Ethernet services, as well as
PDH/SDH/SONET or hybrid Ethernet and TDM interfaces.
This innovative platform uses an “on-the-fly” upgrade method, whereby network operators only buy capacity as
needed, benefiting from savings on initial investments and OPEX.
Traffic capacity throughput and spectral efficiency are optimized with the desired channel bandwidth. For
maximum user choice flexibility, channel bandwidths can be selected together with a range of modulations ranging
from QPSK to 256 QAM.
High spectral efficiency is ensured using the same bandwidth for double the capacity, via two carriers, with vertical
and horizontal polarizations. This feature is implemented by a built-in XPIC mechanism.
ODU-C is commonly used with indoor units (IDUs) such as the MDS Intrepid-HC, and other compatible Intrepid
models. Together, the MDS ODU-C and Intrepid IDU provide a powerful, reliable, and comprehensive solution for
a variety of wireless network scenarios and requirements.

ODU-C works with: MDS Intrepid-HC, & other compatible IDUs

With the ODU-C operating in co-channel dual polarization (CCDP) mode, using the cross polarization interference
canceller (XPIC) algorithm, two carrier signals can be transmitted over a single channel, using both vertical and
horizontal polarization. This enables double capacity in the same spectrum bandwidth.

Required Tools
The following tools are required for the ODU-C installation:
 Socket key wrench metric set
 Adjustable wrench

MDS ODU-C Installation Guide 1-1


Installation Components
The following illustrations show the components involved in the installation procedures.

ODU-C

Coupler Holder with Coupler V/H Twist

Remote Pole Mount Kit

MDS ODU-C Installation Guide 1-2


1+0 Direct Mount Installation
To install ODU-C in a direct mount 1+0 configuration, perform the following steps:

1. If needed, change the antenna polarization by rotating the ODU-C in accordance with the relevant antenna
installation guide.

Vertical Pole Horizontal Pole

2. Spread grease on the O-ring supplied with the antenna.

3. Place the O-ring in its location on the antenna transition.

4. Remove the sticker from the ODU-C antenna interface.

MDS ODU-C Installation Guide 1-3


5. Mount the ODU-C on the antenna according to the system configuration, and make sure that the twist is set for
the desired polarization (horizontal or vertical).

6. Insert four screws and washers provided with the kit, and tighten them.

MDS ODU-C Installation Guide 1-4


1+1 Direct Mount Installation
To install ODU-C in a direct mount 1+1 configuration, perform the following steps:

1. If needed, change the antenna polarization according to the relevant antenna installation guide.
2. Spread grease on the two O-rings supplied with the kit and place them in their locations.
3. Mount the twist on the coupler according to the relevant antenna polarization (as shown in the illustrations
below), using four screws and washers supplied with the kit.

MDS ODU-C Installation Guide 1-5


4. Spread grease on the O-ring supplied with the antenna.
5. Place the O-ring on the antenna transition.
6. Mount the coupler holder on the antenna using the screws and washers supplied with the kit.

7. Spread grease on the O-rings supplied with the holder coupler kit.
8. Place one O-ring on each side of the coupler.
9. Remove the sticker from both ODU-C antenna interfaces.
10. Mount both ODU-Cs on the holder coupler.
11. For each ODU-C, insert four screws and washers, and tighten them, as shown in the following illustration.

MDS ODU-C Installation Guide 1-6


MDS ODU-C Installation Guide 1-7
1+0 Remote Mount Installation
1. Secure the remote mount device on the pole, as shown in the following illustration.

2. Remove the sticker from the ODU-C antenna interface.

3. Mount the ODU-C on the remote mount device.

MDS ODU-C Installation Guide 1-8


4. Insert four screws and washers, and tighten them.

5. Spread grease on the O-ring supplied with the flexible waveguide.

6. Place the O-ring in the flexible waveguide flange groove.

7. Spread grease on the O-ring supplied with the flexible waveguide.

8. Place the O-ring in the other end of the flexible waveguide flange groove.

9. Mount the flexible waveguide on the antenna, and tighten the screws and washers.

6-13 GHz

15-38 GHz

MDS ODU-C Installation Guide 1-9


1+1 Remote Mount Installation
1. Mount the remote mount device on the pole.

2. Mount the coupler holder on the remote mount device using the screws and washers supplied with the kit.

3. Spread grease on the O-rings supplied with the coupler holder kit.

4. Remove the sticker from both ODU-C antenna interfaces.

MDS ODU-C Installation Guide 1-10


5. Place one O-ring on each side of the coupler.

6. Mount both ODU-Cs on the coupler holder.

7. For each ODU-C, insert four screws and washers, and tighten them.

8. Spread grease on the O-ring supplied with the flexible waveguide.

9. Place the O-ring in the flexible waveguide flange groove.

10. Mount the flexible waveguide on the coupler, and tighten the screws and washers.

11. Spread grease on the O-ring supplied with the flexible waveguide.

12. Place the O-ring in the other end of the flexible waveguide flange groove.

13. Mount the flexible waveguide on the antenna, and tighten the screws and washers.

MDS ODU-C Installation Guide 1-11


MDS ODU-C Installation Guide 1-12
Mediation Device (Antenna Mount) Losses
Per Terminal Losses (dB)
Configuration Mount Path
6-8 GHz 11 GHz 13-15 GHz 18 GHz 23-32 GHz 38 GHz
Direct - 0.1 0.1 0.1 0.1 0.1 0.1
1+0
Remote - 0.5 0.5 1.2 1.5 1.5 1.5
Main-Main 1.4 1.4 1.4 1.4 1.6 1.8
Direct Sec-Main,
6 66 666
Main-Sec
1+1 HSB
Main-Main 1.9 1.9 2.6 2.9 3.1 3.3
Remote Sec-Main,
6.5 6.5 7.2 7.5 7.5 7.5
Main-Sec
2+0 XPIC Remote - 0.5 0.5 0.5 0.5 0.5 0.5

Notes:
1. The antenna interface is always the ODU-C interface.
2. If other antennas are to be used, an adaptor with a 0.1 dB loss should be considered.

Loss (dB)
Item
6-8 GHz 11 GHz 13-15 GHz 18-32 GHz 38 GHz

Flexible Waveguide 0.5 0.5 1.2 1.5 1.5

Main Coupler 1.4 1.4 1.4 1.5 1.5

Secondary Coupler 6 66 66

Twist 0 00 00

Note: The numbers above are typical losses per component.

MDS ODU-C Installation Guide 1-13


Antenna Connection
ODU-C uses Andrew, RFS and antennas Xian Putian,

The following catalog items should be used:

 Andrew: VHLP/HP series


 RFS: SB/SU series
 Xian Putian: WTG series

ODU-C can be mounted directly for all frequencies (6-38 GHz) using the following antenna types (for integrated
antennas, specific antennas PNs are required):

 Andrew: VHLP series


 RFS: SB/SU series
 Xian Putian: WTG series

For remote mount installations, the following flexible waveguide flanges should be used (millimetric). The same
antenna type (integrated) as indicated above can be used (recommended).
Other antenna types using the flanges listed in the table below may be used.

Frequency Waveguide Waveguide Antenna


(GHz) Standard Flange Flange
6 WR137 PDR70 UDR70
7/8 WR112 PBR84 UBR84
11 WR90 PBR100 UBR100
13 WR75 PBR120 UBR120
15 WR62 PBR140 UBR140
18-26 WR42 PBR220 UBR220
28-38 WR28 PBR320 UBR320

If a different antenna type (CPR flange) is used, a flange adaptor is required. Please contact your factory
representative for details.

MDS ODU-C Installation Guide 1-14


Direct Mount for Nokia FlexiHopper Antennas
ODU-C can be directly mounted on a Nokia FlexiHopper 6-38 GHz, 1-6 ft antenna, in 1+0 and 1+1 configurations.

An adapter is used for the direct mount, as shown in the following illustration.

ODU-C to
Nokia
FlexiHopper
Antenna
Adapter

MDS ODU-C Installation Guide 1-15


ODU-C - NSN Adapter Installation
List of Kits

Item Description Quantity


1 ODU-C NSN INTERFACE 1
2 ODU-C O RING 1
3 OD U-C RADIO 1
4 SCREW SOCKET HEAD M8 4
5 WASHER SPRING LOCK FOR M8 4

Required Tools

Metric offset hexagon key wrench 6

Procedure

1. Prior to the installation, remove the sticker from the ODU-C.

2. Check that the gasket is already mounted on the NSN interface side.

Note: For UBR84 (7 GHz), insert the gasket on the NSN antenna/coupler side.

MDS ODU-C Installation Guide 1-16


3. Insert the O Ring in its groove at the rear side of the ODU-C. Note the
mounting direction, as shown in the section view above.

4. Insert 4 screws and washers (supplied with the ODU-C) through the
ODU-C and NSN adapter, and tighten them.

5. This view shows the unit mounted to the NSN antenna.

Important! For the warranty to be honored, the unit must be installed in accordance with the instructions above.

MDS ODU-C Installation Guide 1-17


1500P ODU Antenna Adaptor
When mounting ODU-C on an antenna upon which a 1500P ODU (11-38 GHz) direct mount was installed
previously, the following adaptor is required (frequency-dependent).

Antenna adaptor used


when replacing 1500P
ODU direct mount

MDS ODU-C Installation Guide 1-18


ODU-C to 1500P Interface Installation
List of Kits

Item Description Quantity Remarks


1 ODU-C/1500P DIRECT MOUNT INTERFACE 1
2 ODU-C RADIO 1 or 2
3 ODU-C COUPLER 1 Optional

Required Tools

Metric offset hexagon key wrench #6


Metric offset hexagon key wrench #3
Screwdriver Phillips #2

Procedure

1. Prior to installation, check the polarization definition on the


1500P antenna. Also, check that the O-ring is mounted properly
on the 1500P antenna.

2. The ODU-C/1500P interface is mounted with vertical


polarization by default. If needed, switch the polarization by
releasing four countersink screws, rotating the central adaptor 90
degrees, and re-tightening the screws.

Pin Location
for
V Polarization

Pin Location
for
H Polarization

MDS ODU-C Installation Guide 1-19


3. Mount the O-Ring (supplied in the ODU-C/1500P interface kit)
on the ODU-C/1500P interface. Note the mounting direction, as
shown in the section view.

For 1+0 Mounting:

4. Prior to the Radio installation, remove the protective sticker from


the radio.

5. Mount the radio to 1500P Interface, using four M8 screws and


washers (supplied with the ODU-C kit) and tighten them.

Pay attention to the radio polarization mounting direction.

MDS ODU-C Installation Guide 1-20


For 1+1 Mounting:

6. Mount the two O-rings (supplied in the Coupler kit) and twist on
the coupler body, as defined in the coupler kit instructions.

Note: For 15 GHz and 18 GHz, an EMI gasket (supplied with


1500P interface) should be mounted between the twist and the
coupler body.

7. Prior to radio installation, remove the protective sticker from both


radios.

8. Mount the coupler on the 1500P Interface using four M8 screws


and washers (supplied in coupler kit), and tighten them.

9. Proceed with mounting the radios, as defined in the coupler kit


instructions.

Important! For the warranty to be honored, install the unit in accordance with the instructions above.

MDS ODU-C Installation Guide 1-21


ODU-C OMT (Orthogonal Mode Transducer) Installation

List of Kits

Item Description Quantity Remarks


1 ANTENNA OMT ADAPTOR 1
2 OD U-C OMT 1
3 ODU-C RADIO 2 One is optional if using item #4 or #5
4 ODU-C OMT ADAPTOR KIT 1 Optional
5 ODU-C OMT SHORT 1 Optional

Required Tools

Metric offset hexagon key wrench 6

Metric offset hexagon key wrench 3

Procedure

1. Prior to the installation, follow the antenna manufacturer


instructions to switch to circular adaptor (remove the existing
rectangular transition, swap the O-ring, and install the circular
transition instead).

2. Mount the OMT kit on the antenna using four M8 screws and
washers (supplied with the OMT kit). Do not tighten them yet, to
allow rotation of the entire assembly.

MDS ODU-C Installation Guide 1-22


3. Mount the two O-Rings (supplied with the OMT kit) on the OMT
body. Note the mounting direction, as shown in the section view.

4. Prior to radio installation, remove the protective sticker from both


radios.

5. Mount both radios, using four M8 screws and washers (supplied


with the ODU-C kit) through the radio and OMT holder, and
tighten them. Note the polarization mounting direction.

6. Tilt the entire assembly, as described in the XPIC link alignment


procedure, to achieve maximum XPD (Cross Polar
Differentiation). After link alignment, tighten the four M8 screws
(left open in step 2 above).

MDS ODU-C Installation Guide 1-23


Remote Configurations

When remote configuration is required, the OMT is attached directly to the antenna and the ODU-Cs are installed
remotely, using a flexible waveguide.

This section describes the required items and procedures for remote installation.

Remote configurations include:

 2+0 (2 x 1+0 remote connection to OMT)

 2+2 (2 x 1+1 remote connection to OMT)

2+0/2+2 Installations

 Frequencies 13-38 GHz do not require adaptors

 Frequencies 6-11 GHz require adaptors, as described below

With ODU-C OMT Adapters:

1. For UDR70, UBR84, and UBR100, mount the O-Ring


(supplied with the OMT kit).

2. For UBR84 and UBR100, mount the OMT adaptor (with its
installed sealing gasket) on the OMT, and tighten using four
M4 screws and washers (supplied with the OMT adaptor kit).

4. For UDR70 (6 GHz), mount OMT Adaptor #1 on the OMT,


and tighten using four M4 screws and washers (supplied with
the OMT adaptor kit). Then mount OMT Adaptor #2 on OMT
Adaptor #1, and tighten using four M4 screws and washers
(supplied with the OMT adaptor kit).

5. For all frequencies, connect the flexible waveguide to its


relevant frequency.

MDS ODU-C Installation Guide 1-24


1+0, ready for 2+0

If you are installing a 1+0 configuration, and want to be ready for 2+0 configurations (double capacity), a "short"
will be used to terminate the unused port. Later, when an additional ODU will be installed on the second port, the
"short" will be removed.

This steps below describe the required items and procedures for the installation.

With ODU-C OMT Short:

1. For UDR70, UBR84, and UBR100, mount the OMT short (with its
installed sealing gasket) using four screws and washers (supplied
with the OMT short kit).

2. For UBR120, UBR140, UBR220, and UBR320, mount the sealing


O-ring and the OMT short using four screws and washers (supplied
with the OMT short kit).

Important! For the warranty to be honored, install the unit in accordance with the instructions above.

MDS ODU-C Installation Guide 1-25


Packing
The equipment should be packed and sealed with moisture absorbing bags.

Transportation
The equipment should be prepared for public transportation. The cargo must be kept dry during transportation, in
accordance with ETS 300 019-1-2, Class 2.3.

It is recommended that the equipment be transported to the installation site in its original packing case.

If intermediate storage is required, the packed equipment must be stored in a dry and cool environment, and out of
direct sunlight, in accordance with ETS 300 019-1-1, Class 1.2.

Inspection
Check the packing lists and verify that the correct equipment part numbers and quantities are found in the packages
that arrived.

MDS ODU-C Installation Guide 1-26


Chapter 2: Acceptance & Commissioning
Procedures

General
This chapter provides recommended Acceptance and Commissioning Procedure for Intrepid
ODU-C. Acceptance and commissioning should be performed after initial setup is complete.

The purpose of this procedure is to verify correct installation and operation of the installed link and the
interoperability with customer end equipment.

Acceptance and Commissioning procedure includes the following stages:

 Site Acceptance Procedure

 Commissioning of radio link in a 1+0 configuration

 Commissioning of radio link in a 1+1 configuration

 Commissioning of radio link in a 2+0 XPIC configuration

The Site Acceptance Procedure is a checklist that summarizes the installation requirements of the site at which
the products were installed.

The commissioning tests cover the required configuration information that should be recorded, and the tests that
should be performed on the radio link in 1+0, 1+1 and 2+0 configurations.

Note: ODU-C works together with two types of indoor units. For SDH/SONET, the ODU works with the
Intrepid 1500R indoor unit. For Ethernet, ODU-C works with the Intrepid-HC indoor unit.

FibeAir® ODU-C Installation Guide 2-1


Site Acceptance Procedure
The purpose of the following procedures is to verify that all installation requirements were noted and checked.
Following this procedure will ensure proper, long-lasting, and safe operation of the product.

The checklist below summarizes the installation requirements of the site.

SITE ACCEPTANCE CHECKLIST

1. SITE INFORMATION
Customer:
Radio model:
Site name:
Site code:
Radio link code:
Site address:
2. ANTENNA MOUNTING

Antenna mount type:

Mount is of sufficient height to clear local obstructions OK


Mount is safely positioned to not cause a safety hazard OK
Mount is secure and perpendicular OK
Mount is grounded as per site specifications OK
All steelwork is Galvanized or Stainless Steel as appropriate OK
3. ANTENNA
Antenna type (model and size):
Antenna is securely fixed to mount OK
Antenna is grounded as per site specifications OK
Antenna sway braces are installed correctly (where
OK
applicable)
Antenna Radome is securely fitted (where applicable) OK
Water drain plugs are fitted and removed, as appropriate OK
Antenna sealing O-Ring is properly fitted and not damaged OK
Antenna/Launch unit polarization is as per link requirements OK

MDS ODU-C Installation Guide 2-2


SITE ACCEPTANCE CHECKLIST
(continued)
4. OUT-DOOR UNIT
Type of ODU mount: (Direct or Remote mount)
ODU is securely mounted to the antenna or pole OK
ODU is grounded as per installation instructions OK
ODU polarization is as per link requirements OK
ODU is installed properly and has no physical damage OK
For Remote-Mount Only:
Remote mount kit is securely mounted to the pole OK
Waveguide has no physical damage and connectors are
OK
sealed
All waveguide bolts are secured using washers and lock-
OK
washers, as appropriate
Flexible waveguide is secured to the pole OK
6. COAX CABLE
Overall cable length:
Cable type:
N-Type connectors assembled properly on the cable OK
Cable connected securely to ODU and IDU OK
Cable connector is weather-proofed (sealed) at the ODU OK
At the ODU, cable has a service/drip loop to prevent
OK
moisture from entering the connector
Cable is secured using suitable restraints to fixed points at
OK
regular intervals (0.5 m recommended)
Cable has no sharp bends, kinks, or crushed areas. All
OK
bends are per manufacturer specifications
Grounding/lightning protection is as per site specifications OK
Lightning protection type and model:
Cable point-of-entry to building/shelter is weather-proof OK
Cable ends are properly labeled OK

MDS ODU-C Installation Guide 2-3


SITE ACCEPTANCE CHECKLIST
(continued)
7. WAVEGUIDE
WG type:
WG is connected securely to ODU and Antenna OK
WG connector is weather-proofed (sealed) at the ODU OK
At the ODU, the WG has a service/drip loop to prevent
OK
moisture from entering the connector
WG is secured using suitable restraints to fixed points at
OK
regular intervals (0.5 m recommended)
WG has no sharp bends, kinks, or crushed areas. All bends
OK
are per manufacturer specifications

WG ends are properly labeled OK

8. IN-DOOR UNIT
IDU is securely mounted to the rack OK
IDU is located in a properly ventilated environment OK
IDU fans are functional and air flow to the fans is not
OK
disrupted
IDU and rack are grounded as per site specifications OK
Traffic cables and connections are properly terminated as
OK
per manufacturer/cable instructions
All cabling is secured, tidy, and visibly labeled OK

9. DC POWER SUPPLY - Two Inputs


Measured DC voltage input to the IDU: (-40.5 to -72 VDC)
Power-Supply maximum current: (at least 3 Ampere)
Power-Supply is properly grounded OK
DC power backup type:
IDU DC connector is secure and the DC input leads are
OK
correctly terminated (no bare wires are visible)
IDU DC connector (+) and (GND) leads are shorted and
OK
GND is grounded
10. RACK INSTALLATION
Rack is mounted to the shelter floor with four screws OK
Rack is mounted to the shelter wall with two screws OK

MDS ODU-C Installation Guide 2-4


SITE ACCEPTANCE CHECKLIST
(continued)
11. REMARKS/NOTES

12. GENERAL INFORMATION


Name:
Title:
Site accepted by: Company:
Signature:
Date:
Name:
Title:
Site approved by: Company:
Signature:
Date:

Site Acceptance Checklist Notes


The following notes provide important additional information about the Site Acceptance Checklist.
1. Antenna Mounting

 Mounting pole is of sufficient height to clear local obstructions, such as parapets, window cleaning
gantries, and lift housings.

 Mounting Pole is of sufficient height, and is safely positioned, so as not to cause a safety hazard. No
person should be able to walk in front of, or look directly into the path of the microwave radio beam.
Where possible, the pole should be away from the edge of the building.

 Mounting pole is secure and perpendicular. If not, problems during antenna alignment may result.

 Mounting pole is grounded as per site specifications. All operators and site owners have specific
requirements regarding the grounding of installations. As a minimum, typical requirements are such that
any metal structure must be connected to the existing lightning protection ground of the building. Where
it extends beyond the 45 degree cone of protection of existing lightning conductors, additional lightning
protectors should be installed.

 All steelwork is Galvanized or Stainless Steel, as appropriate to prevent corrosion.

MDS ODU-C Installation Guide 2-5


2. Antenna

 Antenna is grounded as per site specifications. See the third point in the Antenna Mounting section above.

 Antenna sway braces are fitted and installed correctly, where applicable. Typically, for an antenna of 1.2
m or larger, an extra sway brace is fitted to the mounting frame of the antenna. This sway brace should
not be mounted to the same pole as the antenna, but should be installed directly back to the tower or an
alternative point.

 Antenna Water Drain Plugs are fitted and removed, where appropriate. Some antennas have moisture
drain plugs installed at various points around the antenna. The purpose of these plugs is to allow any
moisture that forms on the inside of the antenna or radome to drip out and prevent a pool within the
antenna. Only the plugs at the bottom of the antenna, after installation, should be removed. All other
plugs should be left in position.

3. ODU (Radio Frequency Unit)

 The ODU is grounded as per installation instructions. See the third point in the Antenna Mounting section
above.

 The ODU polarization is as per link requirements and matches the polarization of the antenna.

4. Indoor Unit

 The main traffic connections are correctly terminated and crimped as per cable and connector
manufacturer instructions. All fiber optic patch leads should be routed carefully and efficiently, using
conduits to prevent damage to the cables.
All other user terminations are secure and correctly terminated.

 All labeling is complete as per site requirements. Labeling is specific to each customer. At a site with
only one installation, labeling may be unnecessary. However, at sites with multiple installations, correct
and adequate labeling is essential for future maintenance operations.
Typical labeling requirements include:
Antenna labels - for link identity and bearing
ODU labels - for link identity, frequency, and polarization
Coax cable labels - for link identity, close to the ODU, IDU, and either end of any joint
IDU labels - for link identity

MDS ODU-C Installation Guide 2-6


1+0 Commissioning Procedure
Scope
This section describes the recommended commissioning tests for a Intrepid ODU-C radio link in a 1+0
configuration.
The purpose of the commissioning tests is to verify correct and proper operation of the product.

Commissioning Test
The following tests should be performed on each installed link.

Link Verification

 “Radio” LED on the IDM front panel is green, indicating the radio link is up.
 Received Signal Level (RSL) is up to +/- 4 dB from the expected (calculated) level at both ends of the
link.
 Radio Bit Error Rate (BER) is 10E-11 or higher.
 If working with ATPC, ATPC is operating as expected (RSL = reference level).
 After connecting test equipment or end equipment to the line interfaces, all LEDs on the front panel of the
IDM are green.

Line Interfaces Test

 155 Mbps Interface - connect SDH/SONET/ATM test equipment to the 155 Mbps interface and
verify error-free operation for at least 1 hour. Use a physical or software loop at the far end.
 FE/GbE Interface - connect a Packet Analyzer to the Fast Ethernet interface and verify error-free
operation (no packet loss) for at least 1 hour. Use a physical loop at the far end.
 2 Mbps/1.5 Mbps - connect PDH test equipment to the E1/T1 interface and verify error-free
operation for at least 1 hour. Use a physical or software loop at the far end.

Interoperability Verification

 Connect customer end equipment to the line interfaces, and verify correct operation.
 Further interoperability tests should be performed in accordance with the specific requirements of the
connected end equipment.

MDS ODU-C Installation Guide 2-7


Management Verification

 Install the element manager software on the PC, and launch the program.
 Verify that you can manage the link and that you are able to perform changes to the link configuration
(frequency channel, Tx power, system name, time & date, etc.) via the element manager software.
 Verify that the software reports the correct parameters when performing the above.
 Verify that there are no active alarms on the link.
 If the management station is located at a remote site (Network Operation Center), verify that the
management station can manage the link and receive traps.

Loopback Operation

 Perform line loopback, IDU loopback, ODU loopback, and Remote loopback, and verify that the system
operates accordingly.

MDS ODU-C Installation Guide 2-8


1+1 Commissioning Procedure
Scope
This section describes the recommended commissioning tests for a Intrepid ODU-C radio link in 1+1 HSB (Hot
Standby) and SD (Space Diversity) or FD (Frequency Diversity) configurations (internal protection).
The purpose of the commissioning tests is to verify correct and proper operation of the product.
Note that in this section:
Primary refers to the ODUs connected to the top-most antenna in an SD configuration.
Secondary refers to the ODUs connected to the bottom antenna in an SD configuration.

Commissioning Tests
The following tests should be performed on each installed link.

Link Verification

The following steps should be repeated for each of the four ODU combinations (Primary-Primary, Primary-
Secondary, Secondary-Primary, Secondary-Secondary).

 “Radio” LED on the IDM front panel is green, indicating the radio link is up.

 Received Signal Level (RSL) is up to +/- 4 dB from the expected (calculated) level at both ends of the
link.

 Radio Bit Error Rate (BER) is 10E-11 or higher.

 If working with ATPC, ATPC is operating as expected (RSL = reference level).

 After connecting test equipment or end equipment to the line interfaces, all LEDs on the front panel of the
IDM are green.

Line Interfaces Test

 155 Mbps interface - connect SDH/SONET/ATM test equipment to the 155 Mbps interfaces
using splitters, and verify error-free operation for at least 1 hour. Use physical loop between the
splitters at the far end.
 FE, GbE interface - connect a Packet Analyzer to the Fast Ethernet interfaces using an FE splitter,
and verify error-free operation (no packet loss) for at least 1 hour. Use a physical loop at the far
end.
 2 Mbps/1.5 Mbps - connect PDH test equipment to the E1/T1 interfaces using splitters, and verify
error-free operation for at least 1 hour. Use a physical loop between the splitters at the far end.

MDS ODU-C Installation Guide 2-9


Switching Tests

Define each of the N channels as preferred (one at a time) for errorless switching to the +1 channel. The regular
channel supports hitless switching to the +1 channel.

155 Mbps Interface

 Connect SDH/SONET/ATM test equipment to the 155 Mbps interfaces using splitters. Use physical loop
between the splitters at the far end. Verify that there are no alarms.

 Perform the following switching tests from one IDM to the other, and verify the system switches
automatically.
- Power: power off the active IDM
- Radio: disconnect the coax cable of the active IDM
- Line: disconnect the 155 Mbps line input of the active IDM
- Management: force a switch using element manager software
 For diversity configurations, verify that each receiver is receiving its own signal, and then mute the active
ODU. Verify that the receiver at the far end still receives from the diversity path. Verify that there are no
errors in the test equipment.

FE, GbE Interface

 Connect a Packet Analyzer to the Fast Ethernet interfaces using splitters. Use a physical loop between the
splitters at the far end. Verify no alarms exist.
 Perform the following switching tests from one IDM to the other, and verify the system switches
automatically.
- Power: power off the active IDM
- Radio: disconnect the coax cable of the active IDM
- Management: force a switch using element manager software

2/1.5 Mbps Interface

 Connect PDH test equipment to the interfaces using splitters. Use a physical loop between the splitters at
the far end. Verify no alarms exist.
 Perform the following switching tests from one IDM to the other, and verify the system switches
automatically.
- Power: power off the active IDM
- Radio: disconnect the coax cable of the active IDM
- Management: force a switch using Element manager software

MDS ODU-C Installation Guide 2-10


Interoperability Verification

 Connect the customer end equipment to the line interfaces and verify correct operation.

 Further interoperability tests should be performed in accordance with the specific requirements of the
connected end equipment.

Management Verification

 Install the element manager software on the PC and launch the program.

 Verify that you can manage the link and that you are able to perform changes to the link configuration
(frequency channel, Tx power, system name, time & date, etc.) via the element manager software.

 Verify that The element manager software reports the correct parameters when performing the above.

 Verify that there are no active alarms on the link.

 If the management station is located a t a remote site (Network Operation Center), verify that the
management station can manage the link and receive traps.

MDS ODU-C Installation Guide 2-11


2+0 XPIC Commissioning Procedure
Scope
This section describes the recommended commissioning tests for a Intrepid ODU-C radio link in a 2+0 XPIC
Co-Channel-Dual-Polarization configuration.

The purpose of the commissioning tests is to verify correct and proper operation of the product.

Important! Since operation of the XPIC system depends on correct installation, make sure the guidelines for
XPIC system installation provided below are followed correctly.

XPIC Installation Guidelines

Antenna and ODU Installation

1. Install the dual polarization antenna and point it in the direction of the other site.

2. Install the two ODUs on a dual polarization antenna using the appropriate mounting kit, and mark the
ODUs with V and H respectively.

IDU-ODU Cable Installation

1. Install two cables between the ODUs and the drawers (IDMs). Note that cable length difference should not
exceed 10 meters.

2. Mark the cables with V and H respectively, and make sure V is connected to the right drawer and H is
connected to the left drawer.

3. Mark the drawers respectively.

Antenna Alignment

1. Power up drawer V on both ends of the link and configure it to the desired frequency channel and
maximum power.

2. Align the antennas, one at a time, until expected RSL is achieved. Make sure the achieved RSL is no more
than +/-4 dB from the expected level.

Polarization Alignment

Polarization alignment is required to verify that the antenna feeds are adjusted, to ensure that the antenna XPD
(Cross Polarization Discrimination) is achieved.

MDS ODU-C Installation Guide 2-12


Polarization adjustment should be done on one antenna only.
1. Power up drawer V on both ends of the link and record the RSL reading on one end.

2. Power off drawer V on that end and power on drawer H.

3. Check the RSL obtained on this ODU on H pol, and compare it to the RSL obtained by the ODU installed
on the V pol.

4. Verify that XPI (Cross Polarization Interference) is at least 25 dB

where:

XPI  RSLPOL  RSLXPOL


RSLPOL  Link RSL with thesamepolarization used at both sites.
RSLXPOL  Link RSL with orthogonalpolarizations used at both sites.

5. If XPI is less than 25 dB, adjust the feed polarization by opening the polarization screw and gently rotating
the feed to minimize the RSLXPOL.
Note that polarization alignment is not always possible since the RSLXPOL may fall below the sensitivity
threshold of the ODU.
It is also recommended to try to maximize the XPI as much as possible, by aligning the polarization.

XPIC Commissioning Tests

Individual Link Verification

Before operating in XPIC configuration, each of the links (V and H) should be commissioned individually in
order to verify its proper operation.

1 Power up only drawer V at both ends and verify its frequency channel and Tx power configuration.
2 Verify that the RSL is no more than +/-4 dB from the expected level.
3 Run BER stability test on the link for at least 15 minutes to ensure error-free operation.
4 Power up only drawer H at both ends and verify its frequency channel and Tx power configuration.
5 Verify that the RSL is no more than +/-4 dB from the expected level.
6 Run BER stability test on the link for at least 15 minutes to ensure error-free operation.

XPIC Configuration Verification

1 Using the XPIC cable, connect the two ODUs at each end to the TNC connectors. Make sure the
cable is no longer than 3 meters.
2 Configure the drawers to work in XPIC mode.
3 Verify that the RSL at all four ODUs is no more than +/-4 dB from the expected level.

MDS ODU-C Installation Guide 2-13


4 Verify that no alarms exist (if a 155 Mbps line is connected).
5 Run BER stability test on each of the 155 Mbps links for at least 1 hour to ensure error-free
operation.

Note: In a 2+2 configuration, repeat each step above for each of the four coupled ODU combinations.

XPIC Recovery Verification

In order to verify XPIC operation, simulate the faults described below.

1 Disconnect the IDU-ODU cable for each of the drawers (one at a time), and verify that the other
link is operating.
2 Disconnect the XPIC cable and check that the relevant alarms are generated.
3 Power down each of the drawers and verify that the other link is operating.
4 Swap the V and H cables and check that the relevant alarm is generated.
5 Mute and then un-mute one ODU at a time and verify that the other link is operating.

Note: In a 2+2 configuration, repeat each step above for each of the four coupled ODUs connected to the two
standby IDUs.

2+2 Verification

Perform the tests specified in Switching Tests in the 1+1 Commissioning Procedure section earlier in this guide.

In this case, the switch will be from a main IDU connected to the main V and main H ODUs, to the secondary
IDU connected to the coupled V and coupled H ODUs.

MDS ODU-C Installation Guide 2-14


Intrepid ODU-C Commissioning Log
The Commissioning Log is an integral part of the commissioning procedure and should be filled in for each
installed link.

The Commissioning Log gathers all relevant information regarding the installed link and contains a checklist of
all recommended commissioning tests.

Maintaining the Commissioning Log is important for tracking your installations, and to provide essential data
for communication networks.

Upon completing the Commissioning Log, retain the log to for possible future use, or when working with
factory support services.

INTREPID ODU-C LINK COMMISSIONING LOG

1. GENERAL INFORMATION
Customer:
Radio model:
Configuration:
Radio link code:
Site 1 name & add:
Site 2 name & add:

Site 1 Drawers Site 2 Drawers


2. IN-DOOR UNIT Right / Left Right / Left

IDC model:
Wayside channel:
IDC p/n:
IDC s/n:
SW IDC:
Drawer model
Main channel
Drawer p/n
Drawer s/n
Modem s/n
FW Mux:
FW Modem:
Cfg Modem:

MDS ODU-C Installation Guide 2-15


INTREPID ODU-C LINK COMMISSIONING LOG
(continued)
Site 1 Drawers Site 2 Drawers
3. ODU
Right / Left Right / Left

ODU model:
ODU p/n:
ODU Main s/n:
SW ODU:
Tx frequency (MHz):
Rx frequency (MHz):
Link ID:
Tx power (dBm):
ATPC on/off:
ATPC ref level:
ODU polarization:
Site 1 Drawers Site 2 Drawers
4. ANTENNA
Right / Left Right / Left
Antenna model:
Antenna size:
Manufacturer:
Mounting type:
Mounting losses:
Site 1 Drawers Site 2 Drawers
5. LINK PARAMETERS Right / Left Right / Left

Link distance:
Rain zone:
Expected RSL (dBm):
Expected Diversity RSL (dBm):
RSL Main (dBm):
RSL Diversity (dBm):
Deviation from exp?
RSL ≤4 dB?

MDS ODU-C Installation Guide 2-16


INTREPID ODU-C LINK COMMISSIONING LOG
(continued)

Site 1 Drawers Site 2 Drawers


6. COMMISSIONING TESTS Right / Left Right / Left

Front panel LEDs: All green All green All green All green
Line loopback: Pass Pass Pass Pass
IDU loopback: Pass Pass Pass Pass
ODU loopback: Pass Pass Pass Pass
Radio BER: Pass Pass Pass Pass
STM-1 test: Pass Pass Pass Pass
Fast Ethernet test: Pass Pass Pass Pass
8 x E1/T1 test: Pass Pass Pass Pass
E3/DS3 test: Pass Pass Pass Pass
Wayside E1 test: Pass Pass Pass Pass
Wayside Eth test: Pass Pass Pass Pass
XPIC test: Pass Pass Pass Pass
Switching test: Pass Pass Pass Pass

7. MANAGEMENT CONFIGURATION Site 1 Site 2

Eth Main IP address:


Eth Coupled IP address:
Eth IP mask:
Serial IP address:
Serial IP mask:
Default router:
In-band enabled?
Gateway/NE:
In-band channel 1:
In-band channel 2:
Ring IP address:
Ring IP mask:
Network ID:
8. REMARKS/NOTES

MDS ODU-C Installation Guide 2-17


INTREPID ODU-C LINK COMMISSIONING LOG
(continued)
9. INSTALLATION INFORMATION
Name:
Company:
Installed by:
Date:
Signature:
Name:
Company:
Commissioned by:
Date:
Signature:

MDS ODU-C Installation Guide 2-18


Appendix A: Frequency Information
General
This appendix provides frequency information for Intrepid ODU-C.

ODU Frequency Bands


ODU-C is available for ITU-R, CEPT, and FCC channels, in accordance with the table below.

All ODU-Cs (6-38 GHz) support 7-56 MHz bands (for capacities of from 10 to 500 Mbps).

56 MHz bandwidth is supported for all frequencies (6-38 GHz).

The following table lists the frequency bands, sub-bands, and duplex spacing supported by ODU-C.

For a detailed list of the low frequency channels, see the appendix at the end of this document.

Frequency Separation Tx Low Tx High


Standard
Band MHz MHz MHz
ITU-R F.383-7,
(variable) ITU-R F.384-7
252.04,
* 6L GHz CEPT 14-01E 5900-6500 5900-6501
240,260,
266, 300 ITU-R F.497-6
CFR47 101.147

(variable) ITU-R F.383-7


* 6H GHz 340,160, CEPT 14-01E 6400-7100 6400-7101
170,500 CFR47 101.147
ITU-R F.385-7, Annex 3
(variable)
154,161,16 ITU-R F.385-8, Rec 1-4,
* 7 GHz 7100-7900 7100-7900
8,182,196,2 Annex 1,3,4
45,300
CEPT 02-06 Annex 1
(variable)
ITU-R F.386-6,
119,154,20
* 8 GHZ 8,266,300,3 Annex 4,3 7700-8500 7700-8500
10,311.32,5
CEPT 02-06
30

MDS ODU-C Installation Guide A-1


Frequency Separation Tx Low Tx High
Standard
Band MHz MHz MHz
490 ITU-R F.387-9, 10721-10949 11211-11439
CEPT 12-06 rec.12
490 10961-11189 11451-11679
11 GHz CFR47 101.147
530 ITU-R F.387-9, Annex 2 10701-10929 11231-11459
530 CEPT 12-06 rec.3 10941-11169 11471-11699
266 ITU-R F.497-6, 12751-12863 13017-13129
13 GHz
266 CEPT 1202F 12863-12975 13129-13241
315 14648-14760 14963-15075
315 14732-14844 15047-15159
420 14501-14725 14921-15145
ITU-R F.636-3
420 14697-14921 15117-15341
15 GHz
490 14403-14657 114893-15117
ITU-R F.636-3
490 14627-14851 15117-15341
644 ACA (ITU-R F.636-3) 14613-14697 15257-15341
728 CEPT 12-07E 14501-14613 15229-15341
1008,1010 ITU-R F.595-8 17700-18200 18710-19210
1008,1010 CEPT 12-03E 18150-18690 19160-19700
1120 17728-18113 18848-19233
18 GHz
1120 18113-18553 19233-19673
ITU-R F.595-8
1560 17700-18150 19260-19710
CFR47 101.147
ITU-R F.637-3, Annex 3
1008 22000-22600 23000-23600
CEPT 12-02E
1200 CFR47 101.147 21200-21800 22400-23000
23 GHz
1200 ITU-R F.637-3, Annex 4 21800-22400 23000-23600
1232 21224-21784 22456-23016
ITU-R F.637-3, Annex 1
1232 21784-22344 23016-23576
800 24250-24450 25050-25250
26 GHz 1008 ITU-R F.748-4, Annex 2 24549-24997 25557-26005
CEPT 13-02E
1008 24997-25445 26005-26453

MDS ODU-C Installation Guide A-2


1008 27548-27996 28556-29004
28 GHz
1008 27996-28444 29004-29452

Frequency Separation Tx Low Tx High


Standard
Band MHz MHz MHz
812 ITU-R F.1520-2 31815-32207 32627-33019
32 GHz
812 CEPT (01) 32179-32571 32991-33383
700 ITU-R F.749-2, Annex1 38600-38950 39300-39650
CEPT 12-01E
700 38950-39300 39650-40000
CFR47 101.147
38 GHz
1000 38050-38500 39050-39500
1260 ITU-R F.749-2, 37058-37618 38318-38878
1260 Annex 3,1 37618-38178 38878-39438

* Low Frequency Bands and Frequency Channel Allocation

TR Tx Low Tx High
Frequency Channel
Spacing/Block MHz MHz

1-3 5941-6049 6181-6289


240A
4-6 6061-6169 6301-6409
1-4 5931.2-6048.2 6183.2-6300.2
252A 3-6 5992-6106 6244-6358
5-8 6049.8-6166.8 6301.8-6418.8
L6 GHz 1-4 5916.4-6033.3 6168.4-6285.4
252B
5-8 6035-6151.9 6287-6404
1-2 5941-6029 6201-6289
260A
3-4 6061-6149 6321-6409
1-4 5927-6039 6193-6305
266A
5-8 6039-6151 6305-6417
H6 GHz 300A 2-3 5973.5-6091.5 6273.5-6391.5
170A 1-6 6540.5-6609.5 6710.5-6769.5

MDS ODU-C Installation Guide A-3


7-12 6610.5-6669.5 6770.5-6829.5
13-16 6670.5-6709.5 6830.5-6869.5
1-4 6446-6594 6786-6934
340A
5-8 6606-6754 6946-7094
1-4 6426-6574 6766-6914
340B
5-8 6586-6734 6926-7074
340C 1-2 6694-6750 7034-7090

1-2 7428-7484 7582-7638

154A 2-3 7456-7512 7610-7666


3-4 7484-7540 7638-7694
4-5 7512-7568 7666-7722
1-2 7442-7498 7596-7652
7 GHz 154B 2-3 7470-7526 7624-7680
4-5 7526-7582 7680-7736
1-2 7128-7184 7282-7338
2-3 7156-7212 7310-7366
154C
3-4 7184-7240 7338-7394
4-5 7212-7268 7366-7422

TR Tx Low Tx High
Frequency Channel
Spacing/Block MHz MHz

7 GHz 1-2 7124.5-7180.5 7285.5-7341.5


2-3 7152.5-7208.5 7313.5-7369.5
161A
3-4 7180.5-7236.5 7341.5-7397.5
4-5 7203-7264.5 7364-7425.5
1-2 7249.5-7305.5 7410.5-7466.5
161B 2-3 7277.5-7333.5 7438.5-7494.5
4-5 7333.5-7389.5 7494.5-7550.5
1-2 7424.5-7480.5 7585.5-7641.5
161C 2-3 7452.5-7508.5 7613.5-7669.5
4-5 7508.5-7564.5 7669.5-7725.5
161D 1-2 7549.5-7605.5 7710.5-7766.5

MDS ODU-C Installation Guide A-4


2-3 7577.5-7633.5 7738.5-7794.5
4-5 7633.5-7689.5 7794.5-7850.5
1-2 7115.5-7189.5 7276.5-7350.5
2-3 7164.5-7238.5 7325.5-7399.5
161F
4-5 7415.5-7489.5 7576.5-7650.5
5-6 7464.5-7538.5 7625.5-7699.5
1-2 7421-7477 7582-7638
161I 2-3 7449-7505 7610-7666
4-5 7505-7561 7666-7722
1-2 7414-7470 7582-7638
161J 2-3 7442-7498 7610-7666
4-5 7498-7554 7666-7722

TR Tx Low Tx High
Frequency Channel
Spacing/Block MHz MHz

1-2 7485.5-7538.5 7646.5-7699.5


161K
2-3 7513.5-7566.5 7674.5-7727.5
1-2 7443-7499 7611-7667
168B 2-3 7471-7527 7639-7695
4-5 7527-7583 7695-7751
1-2 7414-7470 7596-7652
182A 2-3 7442-7498 7624-7680
7 GHz
4-5 7498-7554 7680-7736
1-3 7107-7191 7303-7387
196A
3-5 7163-7247 7359-7443
1-4 7428-7540 7673-7785
245A
5-8 7540-7652 7785-7897
1-5 7136-7284 7436-7584
300A
6-9 7286-7404 7586-7704
8 GHz 1-3 8279-8335 8398-8454
119A
4-6 8321-8377 8440-8496

MDS ODU-C Installation Guide A-5


1-2 8203-8259 8357-8413
154A 2-3 8231-8287 8385-8441
4-5 8287-8343 8441-8497
1-4 8050-8162 8258-8370
208A
5-7 8162-8246 8370-8454
1-4 8025-8095 8275-8345
250A
5-8 8081-8151 8331-8401
252A 1-2 7976-8034 8228-8286
1-4 7912-8024 8178-8290
266A
5-8 8024-8136 8290-8402
266B 1-2 7926-8010 8192-8276
1-4 7726-7844 8026-8144
300A
5-8 7846-7964 8146-8264
1-3 7731-7839 8041-8149
310A
4-6 7851-7959 8161-8269

TR Tx Low Tx High
Frequency Channel
Spacing/Block MHz MHz

1-3 7905-7989 8215-8299


310C 2-4 7933-8017 8243-8327
4-6 7989-8073 8299-8383
1-2 7905-7989 8215-8299
310D 2-3 7933-8017 8243-8327
8 GHz 4-5 7989-8073 8299-8383
1-4 7733.7-7850.7 8045-8162
311A
5-8 7852.3-7969.3 8163.6-8280.6
1-4 7718.9-7835.8 8030.2-8147.1
311B
5-8 7837.5-7954.4 8148.8-8265.7
530A 1-2 7746-7774 8276-8304

MDS ODU-C Installation Guide A-6


6-8 GHz Frequency Channels
Note: For additional channel schemes, please contact your GE MDS representative.

6L GHz (5.85-6.45 GHz)

ITU-R F.383-7 [1-3]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 5955.00 1 6195.00
2 5995.00 2 6235.00
3 6035.00 3 6275.00
240
4 6075.00 4 6315.00
5 6115.00 5 6355.00
6 6155.00 6 6395.00

ITU-R F.383-7 [0] / FCC 101.147(i8)

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 5945.20 1 6197.24
2 5974.85 2 6226.89
3 6004.50 3 6256.54
4 6034.15 4 6286.19
252.04
5 6063.80 5 6315.84
6 6093.45 6 6345.49
7 6123.10 7 6375.14
8 6152.75 8 6404.79

MDS ODU-C Installation Guide A-7


FCC 101.147(i7)

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz

1 5935.32 1 6187.36
2 5945.2 2 6197.24
3 5955.08 3 6207.12
4 5964.97 4 6217.01
5 5974.85 5 6226.89
6 5984.73 6 6236.77
7 5994.62 7 6246.66
8 6004.5 8 6256.54
9 6014.38 9 6266.42
10 6024.27 10 6276.31
11 6034.15 11 6286.19
12 6044.03 12 6296.07
252.04
13 6053.92 13 6305.96
14 6063.8 14 6315.84
15 6073.68 15 6325.72
16 6083.57 16 6335.61
17 6093.45 17 6345.49
18 6103.33 18 6355.37
19 6113.22 19 6365.26
20 6123.1 20 6375.14
21 6132.98 21 6385.02
22 6142.87 22 6394.91
23 6152.75 23 6404.79
24 6162.63 24 6414.67

MDS ODU-C Installation Guide A-8


ITU-R F.384-7

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 5955.00 1 6215.00
2 6015.00 2 6275.00
260
3 6075.00 3 6335.00
4 6135.00 4 6395.00

ITU-R F.497-6 [0]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 5941.00 1 6207.00
2 5969.00 2 6235.00
3 5997.00 3 6263.00
4 6025.00 4 6291.00
266
5 6053.00 5 6319.00
6 6081.00 6 6347.00
7 6109.00 7 6375.00
8 6137.00 8 6403.00

MDS ODU-C Installation Guide A-9


6H GHz (6.45-7.1 GHz)

ITU-R F.384-7

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 6460.00 1 6800.00
2 6500.00 2 6840.00
3 6540.00 3 6880.00
4 6580.00 4 6920.00
340
5 6620.00 5 6960.00
6 6660.00 6 7000.00
7 6700.00 7 7040.00
8 6740.00 8 7080.00

FCC 101.147(k7)

Center Center
T/R n
Frequency n (H) Frequency
Separation (L)
MHz MHz

1 6545 1 6715
170 2 6555 2 6725
3 6565 3 6735
160 4 6585 4 6745
5 6595 1 6755
6 6605 2 6765
7 6615 3 6775
8 6625 4 6785
9 6635 5 6795
10 6645 6 6805
11 6655 7 6815
12 6665 8 6825
13 6675 9 6835
14 6685 10 6845

MDS ODU-C Installation Guide A-10


15 6695 11 6855
16 6705 12 6865

7 GHz (7.1-7.9 GHz)

ITU-R 385-7 [1]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 7442 1 7596
2 7470 2 7624
154A 3 7498 3 7652
4 7526 4 7680
5 7554 5 7708

ITU-R 385-7 [1]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 7456 1 7610
2 7484 2 7638
154B 3 7512 3 7666
4 7540 4 7694
5 7568 5 7722

ITU-R 385-7 [0]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 7138.5 1 7299.5
2 7226 2 7387
161
3 7428 3 7589
4 7526 4 7687

MDS ODU-C Installation Guide A-11


ITU-R 385-7 [1]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 7442 1 7687
2 7470 2 7715
3 7498 3 7743
4 7526 4 7771
245
5 7554 5 7799
6 7582 6 7827
7 7610 7 7855
8 7638 8 7883

ITU-R 385-7 [0]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
161A 1 7138.5 1 7299.5
2 7166.5 2 7327.5
3 7194.5 3 7355.5
4 7222.5 4 7383.5
5 7250.5 5 7411.5
11 7145.5 11 7306.5
12 7173.5 12 7334.5
13 7201.5 13 7362.5
14 7229.5 14 7390.5
21 7152.5 21 7313.5
22 7180.5 22 7341.5
23 7208.5 23 7369.5
24 7236.5 24 7397.5
31 7159.5 31 7320.5
32 7187.5 32 7348.5

MDS ODU-C Installation Guide A-12


33 7215.5 33 7376.5
34 7243.5 34 7404.5

ITU-R 385-7 [0]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 7263.5 1 7424.5
2 7291.5 2 7452.5
3 7319.5 3 7480.5
4 7347.5 4 7508.5
5 7375.5 5 7536.5
11 7270.5 11 7431.5
12 7298.5 12 7459.5
13 7326.5 13 7487.5
161B 14 7354.5 14 7515.5
21 7277.5 21 7438.5
22 7305.5 22 7466.5
23 7333.5 23 7494.5
24 7361.5 24 7522.5
31 7284.5 31 7445.5
32 7312.5 32 7473.5
33 7340.5 33 7501.5
34 7368.5 34 7529.5

MDS ODU-C Installation Guide A-13


ITU-R 385-7 [0]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 7438.5 1 7599.5
2 7466.5 2 7627.5
3 7494.5 3 7655.5
4 7522.5 4 7683.5
5 7550.5 5 7711.5
11 7445.5 11 7606.5
12 7473.5 12 7634.5
13 7501.5 13 7662.5
161C 14 7529.5 14 7690.5
21 7452.5 21 7613.5
22 7480.5 22 7641.5
23 7508.5 23 7669.5
24 7536.5 24 7697.5
31 7459.5 31 7620.5
32 7487.5 32 7648.5
33 7515.5 33 7676.5
34 7543.5 34 7704.5

MDS ODU-C Installation Guide A-14


ITU-R 385-7 [0]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 7563.5 1 7724.5
2 7591.5 2 7752.5
3 7619.5 3 7780.5
4 7647.5 4 7808.5
5 7675.5 5 7836.5
11 7570.5 11 7731.5
12 7598.5 12 7759.5
13 7626.5 13 7787.5
161D 14 7654.5 14 7815.5
21 7577.5 21 7738.5
22 7605.5 22 7766.5
23 7633.5 23 7794.5
24 7661.5 24 7822.5
31 7584.5 31 7745.5
32 7612.5 32 7773.5
33 7640.5 33 7801.5
34 7668.5 34 7829.5

ITU-R 385-7 [0]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 7435 1 7596
2 7463 2 7624
161I 3 7491 3 7652
4 7519 4 7680
5 7547 5 7708

MDS ODU-C Installation Guide A-15


ITU-R 385-7 [0]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 7428 1 7589
2 7456 2 7617
161J 3 7484 3 7645
4 7512 4 7673
5 7540 5 7701

ITU-R 385-7 [0]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 7498 1 7659
161K 2 7526 2 7687
3 7554 3 7715

ITU-R 385-7 [3]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 7457 1 7625
2 7485 2 7653
168B 3 7513 3 7681
4 7541 4 7709
5 7569 5 7737

MDS ODU-C Installation Guide A-16


ITU-R 385-7 [1]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 7428 1 7610
2 7456 2 7638
182 3 7484 3 7666
4 7512 4 7694
5 7540 5 7722

ITU-R 385-7 [3]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 7121 1 7317
2 7149 2 7345
196 3 7177 3 7373
4 7205 4 7401
5 7233 5 7429

ITU-R 385-7 [4]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
245 1 7442 1 7687
2 7470 2 7715
3 7498 3 7743
4 7526 4 7771
5 7554 5 7799
6 7582 6 7827

MDS ODU-C Installation Guide A-17


7 7610 7 7855
8 7638 8 7883

8 GHz (7.8-8.5 GHz)

ITU-R 386-6 [4]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 7926 1 8192
2 7954 2 8220
3 7982 3 8248
4 8010 4 8276
266
5 8038 5 8304
6 8066 6 8332
7 8094 7 8360
8 8122 8 8388

ITU-R 386-6 [1]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 7747.70 1 8059.02
2 7777.35 2 8088.67
3 7807.00 3 8118.32
4 7836.65 4 8147.97
311.32A
5 7866.30 5 8177.62
6 7895.95 6 8207.27
7 7925.60 7 8236.92
8 7955.25 8 8266.57

MDS ODU-C Installation Guide A-18


ITU-R 386-6 [1]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 7732.875 1 8044.195
2 7762.525 2 8073.845
3 7792.175 3 8103.495
4 7821.825 4 8133.145
311.32B
5 7851.475 5 8162.795
6 7881.125 6 8192.445
7 7910.775 7 8222.095
8 7940.425 8 8251.745

ITU-R 386-6 [3]

Center Center
T/R n n
Frequency Frequency
Separation (L) (H)
MHz MHz
1 8293 1 8412
2 8307 2 8426
3 8321 3 8440
119
4 8335 4 8454
5 8349 5 8468
6 8363 6 8482

MDS ODU-C Installation Guide A-19


MDS ODU-C Installation Guide A-20
IN CASE OF DIFFICULTY...
GE MDS products are designed for long life and trouble-free operation. However, this equipment, as with
all electronic equipment, may have an occasional component failure. The following information will assist
you in the event that servicing becomes necessary.

TECHNICAL ASSISTANCE

Technical assistance for GE MDS products is available from our Technical Support Department during
business hours (8:00 A.M.–5:30 P.M. Eastern Time). When calling, please give the complete model
number of the product, along with a description of the trouble/symptom(s) that you are experiencing. In
many cases, problems can be resolved over the telephone, without the need for returning the unit to the
factory. Please use one of the following means for product assistance:
Phone: 585 241-5510 E-Mail: gemds.techsupport@ge.com
FAX: 585 242-8369 Web: www.gemds.com

FACTORY SERVICE

Component level repair of this equipment is not recommended in the field. Many components are installed
using surface mount technology, which requires specialized training and equipment for proper servicing.
For this reason, the equipment should be returned to the factory for any PC board repairs. The factory is
best equipped to diagnose, repair and align your unit to its proper operating specifications.
If return of the equipment is necessary, you must obtain a Service Request Order (SRO) number. This
number helps expedite the repair so that the equipment can be repaired and returned to you as quickly as
possible. Please be sure to include the SRO number on the outside of the shipping box, and on any corre-
spondence relating to the repair. No equipment will be accepted for repair without an SRO number.
SRO numbers are issued online at www.gemds.com/support/product/sro/. Your number will be issued
immediately after the required information is entered. Please be sure to have the model number(s), serial
number(s), detailed reason for return, “ship to” address, “bill to” address, and contact name, phone number,
and fax number available when requesting an SRO number. A purchase order number or pre-payment will
be required for any units that are out of warranty, or for product conversion.
If you prefer, you may contact our Product Services department to obtain an SRO number:
Phone Number: 585-241-5540
Fax Number: 585-242-8400
E-mail Address: productservices@gemds.com
The equipment must be properly packed for return to the factory. The original shipping container and pack-
aging materials should be used whenever possible. All factory returns should be addressed to:
GE MDS, LLC
Product Services Department
(SRO No. XXXX)
175 Science Parkway
Rochester, NY 14620 USA
When repairs have been completed, the equipment will be returned to you by the same shipping method
used to send it to the factory. Please specify if you wish to make different shipping arrangements. To
inquire about an in-process repair, you may contact our Product Services Group using the telephone, Fax,
or e-mail information given above.
GE MDS, LLC
175 Science Parkway
Rochester, NY 14620
General Business: +1 585 242-9600
FAX: +1 585 242-9620
Web: www.gemds.com