Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
D351019X012/00813-0100-4276
Bulletin 62.1: Communicator
April 2005 375 Field Communicator
www.fieldcommunicator.com
Product Data Sheet
April 2005 375 Field Communicator
We made sure that the weight was
evenly distributed for comfortable
one-handed operation in the field.
■ It is loaded!
Page 2
Product Data Sheet
April 2005 375 Field Communicator
Designed not only for use on the bench, the 375 Field Communicator
enables you to do those tasks that just have to be done in the field.
■ Universal – HART® and in your plant. Use it to perform With over 600 different HART and
FOUNDATION™ fieldbus diagnostics for effective start-up FOUNDATION fieldbus devices from
The 375 Field Communicator is and troubleshooting of FOUNDATION more than 100 different vendors,
designed to support all HART fieldbus segments. Create a quality having a single field communicator
and FOUNDATION fieldbus devices. If segment by diagnosing the network that works with everything is a big
you are familiar with the 275 DC voltage and average noise. help. So, grab the 375 Field
HART Communicator, used in Detect power supply problems Communicator and go!
for more than ten years, you will on a segment. Locate incorrect
Page 3
Product Data Sheet
April 2005 375 Field Communicator
Easy Upgrade allows communication between the 375 Field Communicator and a PC using IrDA.
The IrDA port enables transfer of configuration data between the 375 and AMS Device Manager
as well as upgrading of new Device Descriptions and functionality.
New HART ® and FOUNDATION™ fieldbus DD’s become available, center to have new DD’s or
fieldbus devices, as well as download them from the Internet software updates added.
functional updates to existing and upgrade your 375 Field No longer is it necessary to
by device vendors. Keeping In addition, as functional while you wait for upgrades.
up-to-date with the required enhancements to the 375 Easy Upgrade lets you update
Device Description drivers for all HART and FOUNDATION fieldbus your own 375 Field Communicator.
the devices in your plant can be applications become available, On your site, within your control,
a real challenge. Now, with the download software updates from when it’s convenient for you.
Page 4
Product Data Sheet
April 2005 375 Field Communicator
■ Intrinsically safe Even the battery pack is approved As for reliable, when was the
The 375 Field Communicator meets for installation in hazardous areas. last time you had to send your
the Intrinsic Safety requirements The 375 Field Communicator is 275 HART® Communicator in for
of the listed regulatory agencies designed for use in areas where repair? That’s exactly the kind of
and standards. All of the available laptops shouldn’t go. reliability we’ve built into the 375.
Hazardous Locations approvals ■ Rugged and reliable The 375 Field Communicator is
Specifications
Processor and Memory POWER SUPPLY Specifications ENVIRONMENTAL Specifications
Specifications
Battery Pack Usage
Microprocessor ■ Rechargeable NiMH batteries ■ -10° C (14° F ) to +50° C (122° F )
■ 80 MHz Hitachi® SH3 ■ 0% to 95% RH (non-condensing)
Battery Operating Time
Memory Internal Flash ■
for 0° C (32° F ) to +50° C (122° F )
Up to ten hours depending on usage
■ 32 MB Charge
Battery Charger Options ■
System Card ■
0° C (32° F ) to +40° C (104° F )
Input voltage 85-240 VAC, 50/60 Hz
■ 128 MB or higher secure digital card ■ Cables included with U.S., European Storage
RAM and U.K. plugsONNECTION ■ -20° C (-4° F ) to +55° C (131° F )
■ 32 MB with batteries
CONNECTION Specifications
Expansion Module Storage Without Batteries
■ 32 MB or higher secure digital card
Battery Charger ■ -20° C (-4° F ) to +60° C (140° F )
■ Mini DIN 4-pin jack
Enclosure Rating
PHYSICAL Specifications ■ IP51 (from front)
HART and Fieldbus
Weight ■ Three 4mm banana plugs (one common Shock
■ Approximately 2 lb. (0.9kg) with battery to HART and FOUNDATIONTM fieldbus) ■ Tested to survive a 1-meter
Display drop test onto concrete
IrDA Port
■ 1/4 VGA (240 by 320 pixels) ■ IrDA (Infrared Data Access) port
monochrome 3.8” (9.6 cm) transflective EASY UPGRADE REQUIREMENTS
supporting up to 115 Kbps
display with touch screen ■ ± 15 degrees recommended maximum Usage
■ Anti-glare coated angle from center line ■ PC with internet access
■ Approximately 12” (30 cm) ■ CD Rom drive
Keypad
recommended maximum distance ■ IrDA port (or adapter)
■ 25 keys including 4 action keys,
■ Windows 2000 or XP
12 alphanumeric keys, 4 programmable
function keys, on/off, and 4 cursor-control
(arrow) keys; membrane design with
tactile feedback
Page 5
Product Data Sheet
April 2005 375 Field Communicator
■ Interfaces with AMS™ Suite: AMS Device Manager uses the of device configurations safely
Intelligent Device Manager. intelligence from field devices to in your 375 Field Communicator.
Page 6
Product Data Sheet
April 2005 375 Field Communicator
Power Supply/Charger
(90-240 VAC, 50/60Hz, US/UK/EU connection types included) 00375-0003-0011
(1) For use with AMS Device Manager/375 Interface or 375 Easy Upgrade Programming Utility.
(2) Includes unlimited upgrades to System Card for 3 year period.
(3) Contains 375 Programming Utility and System Software/DD database.
This CD is updated quarterly.
Page 7
Product Data Sheet
April 2005 375 Field Communicator
www.fieldcommunicator.com