VEGAPULS 67
4 … 20 mA/HART
Radar
Contents
Contents
1 About this document
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Target group . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.3 Symbolism used . . . . . . . . . . . . . . . . . . . . . . . 5
2 For your safety
2.1 Authorised personnel . . . . . . . . . . . . . . . . . . .. 6
2.2 Appropriate use. . . . . . . . . . . . . . . . . . . . . . .. 6
2.3 Warning about misuse . . . . . . . . . . . . . . . . . .. 6
2.4 General safety instructions . . . . . . . . . . . . . . .. 6
2.5 CE conformity . . . . . . . . . . . . . . . . . . . . . . . .. 6
2.6 Fulfilling NAMUR recommendations . . . . . . . .. 7
2.7 FCC/IC conformity (only for USA/Canada) . . . .. 7
2.8 Safety instructions for Ex areas . . . . . . . . . . .. 8
2.9 Manufacturer declaration . . . . . . . . . . . . . . . .. 8
2.10 Functional range of approved instruments . . . .. 9
2.11 Environmental instructions . . . . . . . . . . . . . . .. 9
3 Product description
3.1 Configuration. . . . . . . . . . . . . . . . . . . . . . . . .. 10
3.2 Principle of operation . . . . . . . . . . . . . . . . . . .. 11
3.3 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . .. 12
3.4 Storage and transport . . . . . . . . . . . . . . . . . .. 12
4 Mounting
4.1 General instructions. . . . . . . . . . . . . . . . . . . . . 13
4.2 Mounting preparation . . . . . . . . . . . . . . . . . . . . 14
4.3 Mounting instructions . . . . . . . . . . . . . . . . . . . . 17
2 VEGAPULS 67 - 4 … 20 mA/HART
Contents
10 Supplement
10.1 Technical data. . . . . . . . . . . . . . . . . . . . . . . .. 53
10.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . .. 59
10.3 Industrial property rights. . . . . . . . . . . . . . . . .. 63
10.4 Trademark . . . . . . . . . . . . . . . . . . . . . . . . . .. 63
32938-EN-070418
VEGAPULS 67 - 4 … 20 mA/HART 3
Contents
4 VEGAPULS 67 - 4 … 20 mA/HART
About this document
Ex applications
This symbol indicates special instructions for Ex applications.
l List
The dot set in front indicates a list with no implied sequence.
à Action
This arrow indicates a single action.
1 Sequence
Numbers set in front indicate successive steps in a procedure.
32938-EN-070418
VEGAPULS 67 - 4 … 20 mA/HART 5
For your safety
2.5 CE conformity
VEGAPULS 67 is in CE conformity with EMC (89/336/EWG)
and LVD (73/23/EWG).
32938-EN-070418
6 VEGAPULS 67 - 4 … 20 mA/HART
For your safety
VEGAPULS 67 - 4 … 20 mA/HART 7
For your safety
8 VEGAPULS 67 - 4 … 20 mA/HART
For your safety
VEGAPULS 67 - 4 … 20 mA/HART 9
Product description
3 Product description
3.1 Configuration
Scope of delivery The scope of delivery encompasses:
l VEGAPULS 67 radar sensor
l Mounting strap (option)
l Compression or adapter flange (optional)
l Documentation
- this operating instructions manual
- Operating instructions manual "Indicating and adjust-
ment module" (optional)
- Supplementary instructions manual "Heating for indi-
cating and adjustment module" (optional)
- Supplementary instructions manual "Plug connector for
continuously measuring sensors" (optional)
- Ex-specific "Safety instructions" (with Ex-versions)
- if necessary, further certificates
32938-EN-070418
10 VEGAPULS 67 - 4 … 20 mA/HART
Product description
Functional principle The antenna of the radar sensor emits short radar pulses with
a duration of approx. 1 ns. These pulses are reflected by the
product and received by the antenna as echoes. The running
time of the radar pulses from emission to reception is
proportional to the distance and hence to the level. The
determined level is converted into an appropriate output signal
and outputted as measured value.
VEGAPULS 67 - 4 … 20 mA/HART 11
Product description
3.3 Operation
VEGAPULS 67 can be adjusted with different adjustment
media:
l with indicating and adjustment module
l with the suitable VEGA DTM in conjunction with an
adjustment software according to the FDT/DTM standard,
e.g. PACTware™ and PC
l with manufacturer-specific adjustment programs AMS™ or
PDM
l with a HART handheld
The entered parameters are generally saved in VEGAPULS
67, optionally also in the indicating and adjustment module or
in PACTware™.
Storage and transport tem- l Storage and transport temperature see "Supplement -
perature Technical data - Ambient conditions"
l Relative humidity 20 … 85 %
32938-EN-070418
12 VEGAPULS 67 - 4 … 20 mA/HART
Mounting
4 Mounting
4.1 General instructions
Installation position Select an installation position you can easily reach for
mounting and connecting as well as later retrofitting of an
indicating and adjustment module. The housing can be rotated
by 330° without the use of any tools. You can also install the
indicating and adjustment module in four different positions
(each displaced by 90°).
Measuring range The reference plane for the measuring range of the sensors is
the contact surface on the side of the antenna cover.
32938-EN-070418
VEGAPULS 67 - 4 … 20 mA/HART 13
Mounting
1 2 3
4
100%
0%
Information:
If the medium reaches the antenna, buildup can form on it and
cause faulty measurements later on.
Wetted materials Make sure that the wetted parts of VEGAPULS 67, especially
the seal and process fitting, are suitable for the existing
process conditions such as pressure, temperature etc. as well
as the chemical properties of the medium.
You can find the specifications in chapter "Technical data" in
the "Supplement".
14 VEGAPULS 67 - 4 … 20 mA/HART
Mounting
VEGAPULS 67 - 4 … 20 mA/HART 15
Mounting
32938-EN-070418
16 VEGAPULS 67 - 4 … 20 mA/HART
Mounting
VEGAPULS 67 - 4 … 20 mA/HART 17
Mounting
d
32938-EN-070418
18 VEGAPULS 67 - 4 … 20 mA/HART
Mounting
80 mm 300 mm
100 mm 400 mm
150 mm 500 mm
3" 11.8 in
4" 15.8 in
6" 19.7 in
Tip:
In new plants, it is useful to incline the vessel socket in the
direction of emptying. False reflections from the vessel wall are
thus reduced and measurement all the way down to the
conical outlet is possible.
32938-EN-070418
VEGAPULS 67 - 4 … 20 mA/HART 19
Mounting
Mounting in multiple channel The silo walls of multiple chamber silos are often made of
silo profile walls, such as e.g. profile sheetings, to ensure the
required stability. If the radar sensor is mounted very close to a
heavily structured vessel wall, substantial false reflections can
be caused. Hence the sensor should be mounted at a large
distance from the separating wall.
The optimum mounting position is on the outer wall of the silo
with the sensor oriented towards the outlet in the silo center.
20 VEGAPULS 67 - 4 … 20 mA/HART
Mounting
Vessel installations Silo installations such as e.g. ladders, level switches, struts,
and also structured vessel walls, can cause false echoes that
get superimposed on the useful echo. The mounting location
of the radar sensor should be a place where no installations
cross the microwave signals. Make sure when planning your
measurement loop that the radar signals have a "clear view" to
the product.
In case of existing vessel installations, a false echo storage
should be carried out during setup.
If large vessel installations such as struts or supports cause
false echoes, these can be attenuated through supplementary
measures. Small, inclined sheet metal baffles above the
installations scatter the radar signals and prevent direct
interfering reflections.
32938-EN-070418
VEGAPULS 67 - 4 … 20 mA/HART 21
Mounting
Air purging An air purging is useful for avoiding buildup, particularly when
there is strong condensation. Since VEGAPULS 67 has no
direct purging air connection, a separate purging air con-
nection must be provided in the mounting socket. Due to the
inclination of this connection towards the top, the cleaning of
the antenna cover is particularly effective.
Material heaps Large material heaps are best measured with several instru-
ments, which can be mounted on e.g. traverse cranes. For this
type of application it is advantageous to orient the sensor
perpendicular to the bulk solid surface.
The sensors cannot influence each other.
Information:
Keep in mind that for these applications, the sensors are
designed for relatively slow level changes. If the sensor is used
on a movable boom, the max. measuring rate must be
observed (see chapter "Technical data").
32938-EN-070418
22 VEGAPULS 67 - 4 … 20 mA/HART
Connecting to power supply
Take note of safety In hazardous areas you should take note of the appropriate
instructions for Ex regulations, conformity and type approval certificates of the
applications sensors and power supply units.
Select power supply Power supply and current signal are carried on the same two-
wire cable. The voltage supply range can differ depending on
the instrument version.
The data for power supply are stated in chapter "Technical
data" in the "Supplement".
Provide a reliable separation between the supply circuit and
the mains circuits according to DIN VDE 0106 part 101. The
VEGA power supply units VEGATRENN 149A Ex, VEGAS-
TAB 690 as well as all VEGAMETs meet this requirement.
Bear in mind the following factors regarding supply voltage:
l Output voltage of the power supply unit can be lower under
nominal load (with a sensor current of 20.5 mA or 22 mA in
case of fault message)
l Influence of additional instruments in the circuit (see load
values in chapter "Technical data")
Selecting connection cable VEGAPULS 67 is connected with standard two-wire cable
without screen. An outer cable diameter of 5 … 9 mm ensures
the seal effect of the cable gland. If electromagnetic
interference is expected which is above the test values of
EN 61326 for industrial areas, screened cable should be used.
For HART multidrop operation we recommend as standard
practice the use of screened cable.
32938-EN-070418
Cable gland ½ NPT On VEGAPULS 67 with cable gland ½ NPT and plastic
housing, a metal ½" threaded insert is moulded in the plastic
housing.
VEGAPULS 67 - 4 … 20 mA/HART 23
Connecting to power supply
Caution:
No grease should be used when screwing the NPT cable
gland or steel tube into the threaded insert. Standard grease
can contain additives that corrode the connection between
threaded insert and housing. This would influence the stability
of the connection and the tightness of the housing.
Cable screening and ground- If screened cable is necessary, connect the cable screen on
ing both ends to ground potential. In the sensor, the screen must
be connected directly to the internal ground terminal. The
ground terminal on the outside of the housing must be
connected to the potential equalisation (low impedance).
If potential equalisation currents are expected, the connection
on the processing side must be made via a ceramic capacitor
(e.g. 1 nF, 1500 V). The low frequency potential equalisation
currents are thus suppressed, but the protective effect against
high frequency interference signals remains.
24 VEGAPULS 67 - 4 … 20 mA/HART
Connecting to power supply
VEGAPULS 67 - 4 … 20 mA/HART 25
Connecting to power supply
Housing overview
4 4 4
1 2 3
Display
I2C 1
1 2 5 6 7 8
4 2
26 VEGAPULS 67 - 4 … 20 mA/HART
Connecting to power supply
Wiring plan
Display
I2C
1 2 5 6 7 8
Housing overview
1 2 3
4 5
VEGAPULS 67 - 4 … 20 mA/HART 27
Connecting to power supply
Electronics compartment
Display
1
I2C
1 2 5 6 7 8
3 2
Connection compartment
Display
1 2 I²C
28 VEGAPULS 67 - 4 … 20 mA/HART
Connecting to power supply
Wiring plan
I2C
1 2
VEGAPULS 67 - 4 … 20 mA/HART 29
Set up with the indicating and adjustment module PLICSCOM
Information:
This function is available for instruments with national
approvals such as e.g. according to CSA only at a later date.
Note:
You will find detailed information on the adjustment in the
operating instructions manual of the "Indicating and adjustment
module".
30 VEGAPULS 67 - 4 … 20 mA/HART
Set up with the indicating and adjustment module PLICSCOM
Note:
If you intend to retrofit VEGAPULS 67 with an indicating and
adjustment module for continuous measured value indication,
a higher cover with an inspection glass is required.
32938-EN-070418
VEGAPULS 67 - 4 … 20 mA/HART 31
Set up with the indicating and adjustment module PLICSCOM
2
1
1.1
32 VEGAPULS 67 - 4 … 20 mA/HART
Set up with the indicating and adjustment module PLICSCOM
Standard
Address 0
Service
Info
VEGAPULS 67 - 4 … 20 mA/HART 33
Set up with the indicating and adjustment module PLICSCOM
3 Prepare the % value for editing with [OK] and set the
cursor to the requested position with [->]. Set the
requested percentage value with [+] and save with [OK].
The cursor jumps now to the distance value.
4 Enter the appropriate distance value in m (corresponding
to the percentage value) for the empty vessel (e.g. distance
from the sensor to the vessel bottom).
5 Save the settings with [OK] and move to "Max. adjustment"
with [->].
Carrying out max. adjustment Proceed as follows:
Max. adjustment
100.00 %
=
1.000 m(d)
2.000 m(d)
1 Prepare the % value for editing with [OK] and set the
cursor to the requested position with [->]. Set the
requested percentage value with [+] and save with [OK].
The cursor jumps now to the distance value.
2 Enter the appropriate distance value in m (corresponding
to the percentage value) for the full vessel. Keep in mind
that the max. level must lie below the dead band.
3 Save the settings with [OK] and move to "Medium
selection" with [->].
Medium selection Each product has different reflective properties. In solids,
these are dust generation, material cones and additional
echoes caused by the vessel wall. Due to the medium
selection, the sensor is adapted in an optimum way to the
product and the accuracy, particularly for products with bad
reflective properties, is increased considerably.
32938-EN-070418
34 VEGAPULS 67 - 4 … 20 mA/HART
Set up with the indicating and adjustment module PLICSCOM
Medium
Solid
Vessel form Apart from the medium, the vessel shape can also influence
the measurement. To adapt the sensor to these measuring
conditions, this menu item offers different options depending
on whether liquid or solid is selected. With "Solid" these are
"Silo" or "Bunker", with "Liquid", "Storage tank", "Stilling tube",
"Open vessel" or "Stirred vessel".
Vessel form
Silo
Linearisation curve A linearization is necessary for all vessels in which the vessel
volume does not increase linearly with the level - e.g. with a
cylindrical or spherical tank - and the indication or output of the
volume is required. Corresponding linearization curves are
preprogrammed for these vessels. They represent the
correlation between the level percentage and vessel volume.
By activating the appropriate curve, the volume percentage of
the vessel is displayed correctly. If the volume should not be
displayed in percent but e.g. in l or kg, a scaling can be also
set in the menu item "Display".
Linearisation curve
linear
32938-EN-070418
VEGAPULS 67 - 4 … 20 mA/HART 35
Set up with the indicating and adjustment module PLICSCOM
Gating out of false signals False reflections by vessel installation can impair the
measurement as described in chapter "Mounting". A false
echo storage detects and marks these false echoes, so that
they are no longer taken into account for the level measure-
ment. To detect these interfering reflections over the complete
measuring range, the gating out of false echoes should be
carried out with empty vessel.
Information:
However, the measuring signals are not damped by the
product in completely empty, closed metal vessels. Due to
this, considerable multiple reflections can be caused by which
the noise level can increase. In such vessels, it is recom-
mended to carry out the gating out of false echoes with part
filling.
Change now?
Proceed as follows:
1 Move from the measured value display to the main menu
by pushing [OK].
2 Select the menu item "Service" with [->] and confirm with
[OK]. Now the menu item "False signal suppression" is
displayed.
3 Confirm "False signal suppression - Change now" with
[OK] and select in the below menu "Create new". Enter the
actual distance from the sensor to the product surface. All
false signals in this area are detected by the sensor and
saved after confirming with [OK].
Note:
Check the distance to the product surface, because if an
incorrect (too large) value is entered, the existing level will be
saved as false signal. The filling level would then no longer be
detectable in this area.
32938-EN-070418
Extended setting/Quick level The menu item "Extended setting" offers the possibility to
change optimise VEGAPULS 67 for applications with quick level
changes. For this purpose select the function "Quick level
36 VEGAPULS 67 - 4 … 20 mA/HART
Set up with the indicating and adjustment module PLICSCOM
None
Note:
Since with the function "Quick level change >1 m/min." the
generation of an averafy value of the signal processing is
considerably reduced, false reflections by agitators or vessel
installations can cause measured value fluctuations. A false
echo memory is thus recommended.
Copy sensor data This function enables reading out parameter adjustment data
as well as writing parameter adjustment data into the sensor
via the indicating and adjustment module. A description of the
function is available in the operating instructions manual
"Indicating and adjustment module".
The following data are read out or written with this function:
l Measured value presentation
l Adjustment
l Medium
l Inner diameter of the standpipe (with standpipe versions)
l Vessel form
l Damping
l Linearisation curve
l Sensor-TAG
l Displayed value
l Display unit
l Scaling
l Current output
l Unit of measurement
l Language
The following safety-relevant data are not read out or written:
l HART mode
l PIN
l SIL
Copy sensor data
32938-EN-070418
VEGAPULS 67 - 4 … 20 mA/HART 37
Set up with the indicating and adjustment module PLICSCOM
Medium Solid
Damping 0s
Linearization linear
Sensor-TAG Sensor
The values of the following functions are not reset to the reset
values (see chart) with "Reset":
Lighting no reset
Language no reset
SIL no reset
Factory setting
Like basic setting, in addition special parameters are reset to
default values.3)
Pointer
The min. and max. distance values are reset to the actual
value.
32938-EN-070418
38 VEGAPULS 67 - 4 … 20 mA/HART
Set up with the indicating and adjustment module PLICSCOM
VEGAPULS 67 - 4 … 20 mA/HART 39
Set up with the indicating and adjustment module PLICSCOM
Information:
Depending on the version and application, the light-coloured
menu windows are not always available or offer nor selection
possibility.
Basic adjustment
▶ Basic adjustment 1
Display
Diagnostics
Service
Info
Min. adjustment 1.1 Max. adjustment 1.2 Medium 1.3 Vessel form 1.4
0.00 % 100.00 %
= = Solid Silo
4.000 m(d) 1.000 m(d)
3.000 m(d) 2.000 m(d)
0s linear Sensor
Display
Basic adjustment 2
▶ Display
Diagnostics
Service
Info
Displayed value 2.1 Display unit 2.2 Scaling 2.3 Lighting 2.4
Diagnostics
Basic adjustment 3
Display
▶ Diagnostics
Service
Info
32938-EN-070418
40 VEGAPULS 67 - 4 … 20 mA/HART
Set up with the indicating and adjustment module PLICSCOM
Pointer 3.1 Meas. reliability 3.2 Curve selection 3.3 Echo curve 3.4
8 db
Distance min.: 0.234 m(d) Sensor status Echo curve Presentation of the echo
Distance max.: 5.385 m(d) OK curve
Service
Basic adjustment 4
Display
Diagnostics
▶ Service
Info
Gating out of false signals 4.1 Extended setting 4.2 Current output 4.3 Simulation 4.4
Output mode: 4-20 mA
Change now? None Fail.mode: <3.6 mA Start simulation? ▼
min. current: 4 mA
min. current: 4 mA
Info
Basic adjustment 5
Display
Diagnostics
Service
▶ Info
Sensor type 5.1 Date of manufacture 5.2 Last change using PC 5.3 Sensor characteristics 5.4
VEGAPULS 6x 19. February 2007
Software version Display now?
Serial number 3.50 19. February 2007
12345678
32938-EN-070418
VEGAPULS 67 - 4 … 20 mA/HART 41
Set up with the indicating and adjustment module PLICSCOM
32938-EN-070418
42 VEGAPULS 67 - 4 … 20 mA/HART
Setup with PACTware™ and other adjustment programs
VEGACONNECT 3
PACTwareTM/
3 >PA<
1
~
2 Power supply
Necessary components:
l VEGAPULS 67
l PC with PACTware™ and suitable VEGA DTM
l VEGACONNECT 3 with I²C adapter cable (article no.
2.27323)
l Power supply unit
32938-EN-070418
VEGAPULS 67 - 4 … 20 mA/HART 43
Setup with PACTware™ and other adjustment programs
PACTwareTM/
VEGACONNECT 3 1
Necessary components:
l VEGAPULS 67
l PC with PACTware™ and suitable VEGA DTM
l VEGACONNECT 3 with HART adapter cable (art. no.
2.25397)
l HART resistance approx. 250 Ohm
l Power supply unit
Note:
With power supply units with integrated HART resistance
(internal resistance approx. 250 Ohm), an additional external
resistance is not necessary. This applies, e.g. to the VEGA
instruments VEGATRENN 149A, VEGADIS 371, VEGAMET
381). Also usual Ex separators are most of the time equipped
with a sufficient current limitation resistor. In such cases,
VEGACONNECT 3 can be connected parallel to the 4 … 20 mA
cable.
32938-EN-070418
44 VEGAPULS 67 - 4 … 20 mA/HART
Setup with PACTware™ and other adjustment programs
3
TWIST
LO
EN
CK
OP
USB
2 1
TWIST
LO
EN
CK
OP
USB
Necessary components:
32938-EN-070418
l VEGAPULS 67
l PC with PACTware™ and suitable VEGA DTM
l VEGACONNECT 4
VEGAPULS 67 - 4 … 20 mA/HART 45
Setup with PACTware™ and other adjustment programs
CK
LO
TWIST
USB
3
N
OPE
Fig. 30: Connecting the PC to the signal cable
1 VEGAPULS 67
2 HART resistance 250 Ohm (optional depending on the processing)
3 Connection cable with 2 mm pins and terminals
4 Processing system/PLC/Voltage supply
Necessary components:
l VEGAPULS 67
l PC with PACTware™ and suitable VEGA DTM
l VEGACONNECT 4
l HART resistance approx. 250 Ohm
l Power supply unit or processing system
Note:
With power supply units with integrated HART resistance
(internal resistance approx. 250 Ohm), an additional external
resistance is not necessary. This applies, e.g. to the VEGA
instruments VEGATRENN 149A, VEGADIS 371, VEGAMET
381). Also usual Ex separators are most of the time equipped
with a sufficient current limitation resistor. In such cases,
VEGACONNECT 3 can be connected parallel to the 4 … 20 mA
cable.
Note:
Keep in mind that for setup of VEGAPULS 67, DTM-Collection
in the actual version must be used.
46 VEGAPULS 67 - 4 … 20 mA/HART
Setup with PACTware™ and other adjustment programs
VEGAPULS 67 - 4 … 20 mA/HART 47
Maintenance and fault rectification
24 hour service hotline However, should these measures not be successful, call the
VEGA service hotline in urgent cases under the phone no. +49
1805 858550.
The hotline is available to you 7 days a week round-the-clock.
Since we offer this service world-wide, the support is only
available in the English language. The service is free of
charge, only the standard telephone costs will be charged.
l Level fluctuations
à Set integration time via the indicating/adjustment
module
48 VEGAPULS 67 - 4 … 20 mA/HART
Maintenance and fault rectification
? 4 … 20 mA signal missing
l Wrong connection
à Check connection according to chapter "Connection
steps" and if necessary, correct according to chapter
"Wiring plan"
l No voltage supply
à Check cables for breaks; repair if necessary
l supply voltage too low or load resistance too high
à Check, adapt if necessary
? Current signal greater than 22 mA or less than 3.6 mA
l Electronics module defective
à Exchange instrument or return instrument for repair
? E017
l Adjustment span too small
à Carry out a fresh adjustment and increase the distance
between min. and max. adjustment
? E036
l no operable sensor software
à Carry out a software update or send the instrument for
repair
VEGAPULS 67 - 4 … 20 mA/HART 49
Maintenance and fault rectification
Sensor serial number The order data of the sensor must be downloaded into the new
electronics module. This can be done:
l at the factory by VEGA
l or on site by the user
In both cases, the sensor serial number is necessary. The
serial numbers are stated on the type label of the instrument or
on the delivery note.
Information:
When loading on site, the order data must be downloaded from
the Internet (see Operating Instructions manual "Oscillator").
Assignment The oscillators are adapted to the respective sensor and differ
in their signal output or in their power supply. You can find a
suitable oscillator in the following overview.
By doing this you help us carry out the repair quickly and
without having to call for needed information.
l Print and fill out one form per instrument
50 VEGAPULS 67 - 4 … 20 mA/HART
Maintenance and fault rectification
VEGAPULS 67 - 4 … 20 mA/HART 51
Dismounting
9 Dismounting
9.1 Dismounting steps
Warning:
Before dismounting, be aware of dangerous process con-
ditions such as e.g. pressure in the vessel, high temperatures,
corrosive or toxic products etc.
9.2 Disposal
The instrument consists of materials which can be recycled by
specialised recycling companies. We use recyclable materials
and have designed the electronics to be easily separable.
WEEE directive 2002/96/EG
This instrument is not subject to the WEEE directive 2002/96/
EG and the respective national laws (in Germany, e.g.
ElektroG). Pass the instrument directly on to a specialised
recycling company and do not use the municipal collecting
points. These may be used only for privately used products
according to the WEEE directive.
Correct disposal avoids negative effects to persons and
environment and ensures recycling of useful raw materials.
Materials: see chapter "Technical data"
If you cannot dispose of the instrument properly, please
contact us about disposal methods or return.
32938-EN-070418
52 VEGAPULS 67 - 4 … 20 mA/HART
Supplement
10 Supplement
10.1 Technical data
General data
316L corresponds to 1.4404 or 1.4435, 304 corresponds to 1.4301
Materials, wetted parts
- Horn antenna PBT-GF30
- Focussing lens PP
- Adapter flange PPH
- Seal, adapter flange FKM (Viton)
Materials, non-wetted parts
- Compression flange PPH
- Mounting strap 304
- Fixing screws, mounting strap 316L
- Fixing screws, adapter flange 304
- Housing Plastic PBT (Polyester), Alu die-casting pow-
der-coated, stainless steel 316L
- Seal ring between housing and NBR (stainless steel housing), silicone (Alu/
housing cover plastic housing)
- Inspection window in housing cover Polycarbonate (UL-746-C listed)
for PLICSCOM
- Ground terminal 316Ti/316L
Max. torque, mounting screws - strap 4 Nm
on the sensor housing
Weight 0.7 … 3.4 kg (1.5 … 7.5 lbs), depending on
housing material
Output variable
Output signal 4 … 20 mA/HART
Signal resolution 1.6 µA
Failure signal Current output unchanged 20.5 mA, 22 mA,
<3.6 mA (adjustable)
Max. output current 22 mA
Load see load diagram under Power supply
Damping (63 % of the input variable) 0 … 999 s, adjustable
32938-EN-070418
VEGAPULS 67 - 4 … 20 mA/HART 53
Supplement
Input variable
Parameter distance between process fitting and product
surface
Min. distance from antenna end 50 mm (1.969 in)4)
Measuring range up to 15 m (49.213 ft)
Measuring accuracy
Resolution, general max. 1 mm (max. 0.039 in)
Deviation6) see diagrams
32938-EN-070418
54 VEGAPULS 67 - 4 … 20 mA/HART
Supplement
30 mm
15 mm
1,0 m 20 m
-15 mm
-30 mm
0.180 in
0.590 in
3.280 ft 65.62 ft
- 0.590 in
- 0.180 in
Ambient conditions
Ambient, storage and transport tem- -40 … +80 °C (-40 … +176 °F)
perature
Process conditions
Vessel pressure -100 … 200 kPa/-1 … 2 bar (-14.5 … 29.0 psi)
Process temperature (measured on the -40 … +80 °C (-40 … +176 °F)
process fitting)
32938-EN-070418
VEGAPULS 67 - 4 … 20 mA/HART 55
Supplement
56 VEGAPULS 67 - 4 … 20 mA/HART
Supplement
Voltage supply
Supply voltage
- Non-Ex instrument 15 … 36 V DC
- EEx ia instrument 15 … 30 V DC
- EExd ia instrument 20 … 36 V DC
Supply voltage with lighted indicating and adjustment module
- Non-Ex instrument 20 … 36 V DC
- EEx ia instrument 20 … 30 V DC
- EExd ia instrument 20 … 36 V DC
Permissible residual ripple
- <100 Hz Uss <1 V
- 100 Hz … 10 kHz Uss <10 mV
Load see diagram
32938-EN-070418
VEGAPULS 67 - 4 … 20 mA/HART 57
Supplement
Ω
1000
750
3
500
1 2
250
4
15 16 18 20 22 24 26 28 30 32 34 36 V
Approvals11)
ATEX D ATEX II 1/2D IP6X T
IECEx IECEx Ex tD A20/A21 IP66 T, A21
FM/CSA (NI) CL I, DIV2; (DIP) CL II, III, DIV1
32938-EN-070418
58 VEGAPULS 67 - 4 … 20 mA/HART
Supplement
10.2 Dimensions
116mm (4 9/16")
117mm (4 39/64")
120mm (4 23/32")
112mm (4 13/32")
Fig. 34: Housing versions in protection IP 66/IP 67 and IP 66/IP 68; 0.2 bar, with integrated indicating and adjustment
module the housing is 9 mm (1/64") higher
1 Plastic housing
2 Stainless steel housing
3 Aluminium double chamber housing
4 Aluminium housing
120mm (4 23/32")
M20x1,5/
1 ½ NPT 2 3
Fig. 35: Housing versions in protection IP 66/IP 68, 1 bar (with integrated indicating and adjustment module the housing is
9 mm/0.4 in higher)
1 Stainless steel housing
2 Aluminium double chamber housing
3 Aluminium housing
32938-EN-070418
VEGAPULS 67 - 4 … 20 mA/HART 59
Supplement
125 mm
2,5 mm (4 59/64")
(1/8")
1.4301
98 mm
19 mm
(3/4")
8,5 mm
(21/64")
(19/32")
15 mm
PP 75 mm
(2 61/64")
107 mm
9 mm (4 7/32")
(15/32")
12 mm
(23/64") 115 mm
(4 17/32")
(3 11/32")
85 mm
(23/64")
9 mm
12 mm
(15/32")
Fig. 36: VEGAPULS 67, version with mounting loop in 170 or 300 mm length
32938-EN-070418
60 VEGAPULS 67 - 4 … 20 mA/HART
Supplement
(4 61/64")
126mm
10,5mm
(13/32")
ø 107mm ø 21mm
(4 7/32") (53/64")
19mm
(3/4")
ø 75mm
(2 61/64")
ø 115mm
(4 17/32")
ø 156mm
(6 9/64")
ø 200mm
(7 7/8")
VEGAPULS 67 - 4 … 20 mA/HART 61
Supplement
mm øD øk ød
DN100 PN16 220 180 18 8x45°(=360°)
DN150 PN16 285 240 22 8x45°(=360°)
ASME" 150psi 228,6 190,5 19,1 8x45°(=360°)
ASME" 150psi 279,4 241,3 22,4 8x45°(=360°)
JIS DN100 10K 210 175 19 8x45°(=360°)
JIS DN150 10K 280 240 23 8x45°(=360°)
inch øD øk ød
DN100 PN16 7 21/32" 7 3/32" 45/64" 8x45°(=360°)
DN150 PN16 11 14/64" 9 29/64" 55/64" 8x45°(=360°)
ASME" 150psi 9” 7 1/2" 3/4" 8x45°(=360°)
ASME" 150psi 11” 9 1/2" 7/8" 8x45°(=360°)
JIS DN100 10K 7 17/64" 6 57/64" 3/4" 8x45°(=360°)
138 mm
(5 7/16")
(19/32")
15 mm
ø 107 mm
(4 7/32") ød
20 mm
(25/32")
(5/16")
8 mm
ø 75 mm
(2 61/64")
ø 98 mm 2
(3 55/64")
ø 115 mm
(4 17/32")
ø 126 mm
(4 61/64")
k
62 VEGAPULS 67 - 4 … 20 mA/HART
Supplement
Les lignes de produits VEGA sont globalement protégées par des droits de
propriété intellectuelle.
Pour plus d'informations, on pourra se référer au site http://www.vega.com.
VEGA系列产品在全球享有知识产权保护。
进一步信息请参见网站<http://www.vega.com>。
10.4 Trademark
All brands used as well as trade and company names are
property of their lawful proprietor/originator.
32938-EN-070418
VEGAPULS 67 - 4 … 20 mA/HART 63
VEGA Grieshaber KG
Am Hohenstein 113
77761 Schiltach
Germany
Phone +49 7836 50-0
Fax +49 7836 50-201
E-mail: info@de.vega.com
www.vega.com
ISO 9001