1- Visual Inspection
2- Meter Reading
5- Loopback Check
SPECIFICATION
Satisfactory
TEST PROCEDURE
1-Composition
Checking the components used in unit and rack.
With serial number of Antenna, ODU and IDU.
2-Structure
Checking the finishing and fittng manner.
3-Wiring
Checking the termination condition and fitting manner.
ON-SITE TEST PROCEDURE
TEST PROCEDURE
1- Connect the PC to the LCT port on the IDU using USB Cable.
SPECIFICATION
satisfactory
TEST SET UP
TEST PROCEDURE
4- At each station, remove the cap from the RX LEV MON connector on the ODU
5- At each station, Connect cables to RX LEV MON connector using F-type plug
And either end of cable connect to digital voltmeter.
8- Remove the cable from the RX LEV MON connector on ODU and set
the cap for this connector
ON-SITE TEST PROCEDURE
SPECIFICATION
Satisfactory
TEST SET UP
TEST PROCEDURE
TEST PROCEDURE
1- Connect the PC to the LCT port on the IDU using USB cable.
6- For Main CH Loopbacl (Near End), Click on the “Select” button and click on
the setting button “On” of the required CH#(s) to be loop back and click on
the “SET” button,
8- Click on the setting button “Off” of the Main CH Loopback (Near End ) and
click on the “Set” button,
9- For Main CH Loopbacl Far End), Click on the “Select” button and click on
the setting button “On” of the required CH#(s) to be loop back and click on
the “SET” button,
11- Click on the setting button “Off” of the Main CH Loopback (Far End ) and
click on the “Set” button,
ON-SITE TEST PROCEDURE
SPECIFICATION
1 Hour errors check
Satisfied to 1 x 10⁻⁹ or less
TEST SET UP
Station A Station B
TEST PROCEDURE
5- Measure BER in one hour and confirm on the PNMTj display that
BER satisfies below requirement :
Requirement : 1x10e-9 or less
6- Set Main CH Loopback (Far End) for selected CHs in "OFF" mode.
SPECIFICATION
RX level interference at sites OK/Not OK
TEST SET UP
Station A Station B
TEST PROCEDURE
P/J
NOV-08
NEC Corporation
Vendor: NEC DATE
CUSTOMER : IDEA CELLULAR LIMITED.
ON-SITE TEST STATION NAME :
DATE SHEETS STATION No. :
SYSTEM
CONFIGURATION TX FREQUENCY :___________________MHz (H/L)
(1+0)___GHZ-___QAM RX FREQUENCY :___________________MHz
Customer Remarks :
2 Cable Length
3 IF Cable Type
4 Antenna dia./Sr.No.
5 Antenna Type
6 Antenna Gain
7 Polarisation
9 Earth Resistance
12 Grounding of ODU
14 Protected/Non-Protected Configuration
Equipment Sr No.
ODU 1
IDU (1+0/1+1)
Table-2: Installation Checks
Customer Remarks: