INTRODUCTION:
OBJECTIVE:
APPARATUS:
3
PROCEDURE:
RESULT:
1. Make-up tank
-To refill the water inside the chiller.
4
2. Float valve
-Allow the water entering the make-up tank into the chiller
when there is any drop of water level.
3. Pump
-Pump hot water from the chiller to the control valve and
to the recirculation.
4. Control valve
-Control the flow of water.
5. Flow meter
-show the flow rate of water.
7. Orifice
-allows the flow of hot air to the surroundings.
8. Droplets arrester
- arrest water vapor so that there will be less water loss in
the system.
9. Damper
-Let the air to enter the system through the air inlet by
blowing air with its fan into the air distribution chamber
5
10. Water Outlet
- let the water flows from the basin into the chiller.
6
chiller
7
DISCUSSION:
2. The water will absorb the heat from the heaters and
automatically being pump through the control valve and then
flow along the water distribution system. Notice that the
water that being pumped flow into two direction, to the
control valve and recirculation.
3. From the water distribution system, the water will fall down
due to gravitation attraction, even the vapor will be block by
the droplet arrester. The water that flow downward will be
separated, this increase the total expose area of water to the
surroundings so that the water will cool faster.
From the bottom, the air inlet will fan (blows) the air form
surroundings into the air distribution chamber. The air will
blow the air from the bottom of the tower up to the orifice.
The air blows alternately with the flow of the water flows, this
cause thermal equilibrium when the hot water particle and air
particle from the surrounding alternately collision with each
others.
8
The water will cools and flow back to the basin and again
flows back into the chiller while the hot air released to the
surroundings through the orifice.
9
Cooling tower air condition system a building
(huge room)
10
C) Is the volume of water inside the cooling water is constant?
The water in the cooling tower system actually will decrease
with small amount. This is because the air blows from the bottom
will evaporate water particle and blows it away through the droplet
arrester although the droplet arrester can filter most of the water
vapor particles. That’s why the system provided a make-up tank
and a float valve, the make-up tank provided water that needs to
refill the water inside the system. The float valve will open the path
for the water in the make-up tank to enter the chiller if there any
drop level of water inside the system.
CONCLUSION
REFERENCE:
11