Sei sulla pagina 1di 10

Overview

Direct Operated Directional Control Valves


Monoblock and Sectional designs
Series HDM and HDS

motion and progress

1 / 10 Classification: 430.10.40.40
Reference: 100--P--000040--E--02 / 05.2005
Contents

1 General description 3

2 Directional valve HDM / HDS


2.1 Design features 3
2.2 Technical data 4
2.3 Configuratins available 4
2.4 Spool types 5
2.5 Spool control types 5
2.6 Hand lever 5
2.7 Ordering code 6

3 Sections with PQ flow control: HDS11 / HDS15


3.1 Design features 7
3.2 Technical data 7
3.3 Ordering code 7
3.4 Types available 8

4 Solenoid operation: HDS07 / HDS11 / HDS15


4.1 Design features 10
4.2 Technical data 10
4.3 Ordering code 10

100--P--000040--E--02 / 05.2005 2 / 10
1 General description
The HDM and HDS series of valves ma- In addition, the valves are used in ge- vings. The constly piping of individual
nufactured by Bucher Hydraulics are neral machine building and in many ty- components is eliminated.
direct operated directional valves with pes of special vehicles.
In addition to the directional valve sec-
a variety of actuator types.
The sectional versions of this range of tions that are needed, a complete valve
Due to their robust design and valves make possible the assembly of block normally also requires an inlet
compact build, they are particularly a customised valve block. Sections section to ’start’ the block and an end
suitable for use in all types of mobile containing pressure-- or flow regulating section to ’finish’ it.
hydraulic systems. Typical examples elements can be incorporated in the
The monoblock version of this valve se-
of their application are found in: valve block.
ries is a compact, well thought out solu-
S tractors and mini--tractors In this way, complex and feature--rich tion for many application areas. Nume-
S agricultural machinery control systems can be integrated into rous options are also available for the
S harvesters one block with significant space sa- monoblock version.
S construction machines
S sweepers
S fork lift trucks

2 Directional valve HDM / HDS

2.1 Design features

Auxiliary valves in the ports

Spoll control

Actuation

Spool

Directional valve sectional body

Check valve

100--P--000040--E--02 / 05.2005 3 / 10
2.2 Technical data

2.2.1 Monoblock HDM140 HDM11P HDM11S HDM18 HDM25


Nominal flow rate l/min 40 45 45 70 100
Operating pressure bar 250 250 350 350 250
Max. back pressure bar 30 30 30 30 30
Number of spool
1 1 to 6 1 to 6 1 to 4 1 to 2
sections

2.2.2 Sectional HDS11 HDS15 HDS20 HDS30 HDS07

Nominal flow rate l/min 45 60 80 120 25


Operating pressure bar 280 320 320 320 250
Max. back pressure bar 30 30 30 30 20
Number of spool
1 to 10 1 to 10 1 to 10 1 to 10 1 to 10
sections

2.3 Configurations available

Configurations
1 2 3 4 5 6 7 8 20 21 23 24 30 31 32 33 34 35 36
HDM140    
HDM11P      
HDM11S            
HDM18            
HDM25              

HDS11              
HDS15                  
HDS20               
HDS30               
HDS07        

2.3.1 Actuator types


1 = with hand lever 4 = hydraulic or pneumatic (on/off) 7 = hydraulic, proportional
2 = with 1 hand lever for 2 spools 5 = electro--hydraulic (on/off) 8 = electro--hydraulic, proportional
3 = for cable operation 6 = electrical (on/off)

2.3.2 Circuitry
20 = parallel--connected (standard) 23 = with high pressure carry--over
21 = series--connected 24 = load sensing

2.3.3 Auxiliary valves


30 = with inlet pressure relief valve 33 = with service line pressure relief 35 = with proportional pressure
31 = with service line pressure relief and anti--cavitation valve compensator
valve 34 = with pilot operated check valve 36 = with pressure--compensated
32 = with anti--cavitation valve flow control valve

100--P--000040--E--02 / 05.2005 4 / 10
2.4 Spool types
A C G
1 0 2 1 0 2 1 0 2
AB A B B

S Z
1 0 2 3 1 0 2
A A B

2.5 Spool control types


01/08 02/10 03/17
201 201 201

19/20 04/128/136
201 3201

2.6 Hand lever


L55 L100 L300

100--P--000040--E--02 / 05.2005 5 / 10
2.7 Ordering code
2.7.1 Monoblock valves, series HDM
Characteristcs of the body Characteristcs of the 1st spool
H DM 1 8 0 2 K 0 1 1 5 A 0 1 L 1 0 0 O A A 1 5 B 2 6 ...
Valve model 2nd spool
140 / 11P / 11S / 18 / 25

Number of spools

Thread type
Ex. K01 = M18x1,5 (standard)

PRV setting (0 to 400 bar)


Ex. 15 = 150 bar (standard)

Spool type (see 2.4)

Spool control type (see 2.5)

Hand lever (see 2.6)

Auxiliary valves
Service line relief and anti--cavitation valve = UC
Anti--cavitation valve = C
Service line relief valve = OA

Setting for the A--line valve

Setting for the B--line valve

2.7.2 Sectional valves, series HDS


Characteristcs of the body Characteristcs of the 1st spool
HD S 1 5 0 2 T 0 1 1 5 P 0 1 0 1 K 0 1 A 0 8 L 1 0 0 O A A 1 5 B 2 6 ...
Valve model 2nd spool
07 / 11 / 15 / 20 / 30

No. of intermediate sections

Inlet section
Ex. T01 = M18x1,5 With PRV

PRV setting (0 to 400 bar)


Ex. 15 = 150 bar (standard)

End section
Ex. P01 = with T -- M18x1,5

Position of the intermediate section in the block

Body style (standard)


HDS11 = K05 with M18x1
HDS15 and HDS20 = K01 with M18x1,5
HDS30 = K02 with 3/4” or 1”

Spool type (see 2.4)

Spool control type (siehe 2.5)

Hand lever (siehe 2.6)

Auxiliary valves
Service line relief and anti--cavitation valve = UC
Anti--cavitation valve = C
Service line relief valve = OA

Setting for the A--line valve

Setting for the B--line valve

100--P--000040--E--02 / 05.2005 6 / 10
3 Sections with PQ flow control HDS11 / HDS15

3.1 Design features

BP3/AE 13HC (12 VDC) BP3/CE 13HC (12 VDC) Ports Body
BP3/AE 23HC (24 VDC) BP3/CE 23HC (24 VDC)
M18X1.5 T/K***/1

1/2” BSP T/K***/3

00VC00 BP3/AE RV1 M22X1.5 T/K***/9

M P
VDP VDPF

T E
E

00EC T P

RV3 Pe P RV2 00VC00


00VC00

3.2 Technical data HDS11 HDS15


Operating pressure bar 320
Nominal flow rate l/min 50 60
Adjustment range l/min 0--6, 12, 40 0--6, 12, 25, 50
Pressure differential (∆p) bar max. 6

3.3 Ordering code


HD S 1 5 K * * / * R V 1 - * * R V 2 - * * R V 3 - * * B P 3 - * * V D P - * *

Series
HDS11/15

Intermediate section: K100--K88--K90


Inlet section: T100--T88--T90

Setting for pressure relief valve 1: RV1/06--15--26


Blanking plug: 00VC00

Setting for pressure relief valve 2: RV2/06--15--26


Blanking plug: 00VC00

Setting for pressure relief valve 3: RV3/06--15--26


Blanking plug: 00VC00

Solenoid bypass valve: BP3/AE 13 HC (12 V.D.C.)


BP3/CE 23 HC (24 V.D.C.)
Blanking plug 00EC

Adjustable flow control valve VDP 06--12--25--50


Non--adjustable flow control valve VDPF

100--P--000040--E--02 / 05.2005 7 / 10
3.4 Types available
3.4.1 Inlet sections

HPCO = high pressure carry--over port


(can be pressurised)
P M B1 A1 B2 A2

Constant flow

VDP

residual flow
HPCO
T100
BP3/AE

T
RV1 RV2 00VC00

T100 KSTD KSTD P100


1_ 2_

D = residual flow port


(can be pressurised)
T3
P M A1 B1 A2 B2

Constant flow

VDP
residual flow

T2
T88

BP3/AE RV2

RV3

D
T88 KSTD KSTD PSERIE
1_ 2_
R = tank port
(can not be pressurised)
T3
P M A1 B1

Constant flow
residual flow

VDP

T2
T90

BP3/AE
RV2

T90 KSTD PSERIE


1_

100--P--000040--E--02 / 05.2005 8 / 10
3.4.2 Intermediate sections

HPCO = high pressure carry--over port


(can be pressurised)

B1 A1 B2 A2 P M B4 A4
Constant flow

residual flow
VDP

HPCO T2
K100
BP3/AE

00VC00
RV1 RV2

PSERIE KSTD KSTD K100 KSTD P100


1_ 2_ 3_ 4_

D= residual flow port


(can be pressurised) M T3
A1 B1 A3 B3 A4 B4

Constant flow
residual flow

VDP

P T2
K88
BP3/AE
RV2

T RV1 RV3

TSERIE KSTD K88 KSTD KSTD PSERIE


1_ 2_ 3_ 4_

R= tank port
(must not be pressurised) T3
A1 B1 P2 M A3 B3

Constant flow
residual flow

VDP

P T2
K90

BP3/AE

RV2

RV1
T
R

TSERIE KSTD K90 KSTD PSERIE


1_ 2_ 3_

100--P--000040--E--02 / 05.2005 9 / 10
4 Solenoid operation HDS 11 / HDS 15

4.1 Design features

Manual override Manual override


40 / 48

268 / 300

4.2 Technical data HDS07 HDS11 HDS15


Operating pressure bar 250 300 280
Flow rate l/min max. 30 max. 40 max. 60

4.3 Ordering code


HD S 1 5 K 2 1 1 A E 0 1 E 2 3 O A A 1 5 B 2 6

Valve model HDS07/11/15

Body type
Ex. K211 = M18x1,5

Spool type

Solenoid control
01E = 2 solenoids
02E / 03E = 1 solenoids

Coil voltage
12 V = 13
24 V = 23

Auxiliary valves
Service line relief and anti--cavitation valve = UC
Anti--cavitation valve = C
Service line relief valve = OA

Setting for the A--line valve

Setting for the B--line valve

BUCHER HYDRAULICS www.bucherhydraulics.com


Germany France Netherlands UK USA
Phone +49 7742 85 20 Phone +33 389 64 22 44 Phone +31 79 34 26 24 4 Phone +44 24 76 35 35 61 Phone +1 262 605 82 80
Fax +49 7742 71 16 Fax +33 389 65 28 78 Fax +31 79 34 26 28 8 Fax +44 24 76 35 35 72 Fax +1 262 605 82 78
info.de@bucherhydraulics.com info.fr@bucherhydraulics.com info.nl@bucherhydraulics.com info.uk@bucherhydraulics.com info.wi@bucherhydraulics.com

Switzerland Italy Austria China Product Center (Elevator)


Phone +41 33 67 26 11 1 Phone +39 0522 92 84 11 Phone +43 6216 44 97 Phone +86 10 64 44 32 38 Phone +41 41 757 03 33
Fax +41 33 67 26 10 3 Fax +39 0522 51 32 11 Fax +43 6216 44 97 4 Fax +86 10 64 44 32 35 Fax +41 41 755 16 49
info.ch@bucherhydraulics.com info.it@bucherhydraulics.com info.at@bucherhydraulics.com info.bj@bucherhydraulics.com info.nh@bucherhydraulics.com

We reserve the right of modification without prior notice.

100--P--000040--E--02 / 05.2005 10 / 10