Sei sulla pagina 1di 3

Side Hung Window / Door Drive FTA 600

(421 mm) Ord.no. 524151

Attention:
Danger of Crushing and Clamping !
The Window Closes Automatically !
Before assembly read enclosed safety instruction, during assembly
and drive operation regard and stick to instruction.
Warrenty claims professional assembly, installation and
!
maintenance according to the guidelines of the manufacturer.

The FTA 600 opens doors or flaps using an electric motor . For a build-laterally locking mechanism a floating free contact for
up 50 V is, to 0.5 A is featuredl. The door opening drive features soft start and stop mode.

24
ø5,5
16

16 Please note:
Depending on the kind of the assembly
is additional the bracket set for
FTA 600 (ord.no. 524156) necessarily.

Technical Data
93° Supply voltage: 19...32 V DC
Qiescent current admission: approx. 40 mA
Max. residual ripple: 2 Vss
411

Cutoff current when opening: max. 1,40 A


421

429
408

when closing: max. 0,46 A


361

Opening torque maximum: 216 Nm


permanent: 180 Nm
Closing torque maximum: 72 Nm
permanent: 72 Nm
Running time: approx. 30 seconds
Protection class: IP 32
Volt free floating contact: max. 50 V, 0,5 A
Connection cable: 5 x 0,5 mm², approx. 5 m

Function mode
Connection cable (5 x 0,5 mm²): approx. 5 m long
When opening first the door latch plate contact is
11 activated ( and ) . The door latch plate recieves 3
impulses per second, then the contact remains
40
LA 1081-52.00.000

closed.
56
86 With a time delay of approx. 5 seconds the door drive
98,5 starts. The drive arm opens up to an angle of 93°.

During the closing procedure the door latch plate


contact is not operated.

Electrical connection
FTA 600
brown 2 Control
from 24 V DC
blue 1 control unit
green
Connection type for
violet - a door latch plate 24 V DC,
brown blue max. 10 W contact rating,
+ + max. 42 V contact consumption
Open -
Close
-
+ white (for single operation isolate white lead or in junction box present)
For programmed synchronisation of two or more drives, the drive must be moun-
! ted and connected according to its allocation number on the programming lable
on the drive. Connect the white leads for synchronized multiple operation.
Single operation with programmed drive is not possible.
Side Hung Window / Door Drive FTA 600
(421 mm) Ord.no. 524151

Assembly without additional brackets

408 21
4 x M5 countersunk 15
head scews
Not delivery included !

40
24 64
101
Mind flow of force 104
at the hing !
90°

KO 1088-51.00.002

Assemply with bracket set for FTA 600


Ord.no. 524156

50
105,5
40

50
50

75

min. 78
max. 117
KO 1088-51.00.003

100 The bracket set for FTA 600 consists of:


When mounting to
door angle mind 1 attaching angle
guidance wheel 1 door angle attachment
1 door angle stop
4 countesunk head screws M5 x 45
90° 3 cheese head screws with female
hexagon M5 x 12
3 tooth lock washer A5,3
Mind flow of force
at the hing !

aumüller aumatic gmbh


Steinerne Furt 58a • 86167 Augsburg
218-3-0-1-8

Postfach 52 12 61 • 86095 Augsburg


Tel.: +49 (0)821 27 09 30 • Fax: +49 (0)821 70 98 42
www.aumueller-aumatic.de
info@ferralux.de
218-3-0-1-1.1 AK 12.08
Safety Instructions for Drives
Read before assembly and keep safety instructions over life-span of drive !
Symbols for Safety Instructions:
Danger of Crushing and Clamping !
The Window Closes Automatically ! Caution !
Danger - electric current !
During closing and opening the drive stops with its integrated
or external overload disconnection (depending on type of drive).
Caution !
For corresponding pressing force please consult technical data. Danger of crushing and clamping
Caution - pressing force is sufficient to result in serious by drive operation
injury (crushing) to fingers. During assembly and operation, (sticker furnished with drive)
keep fingers away from window gap and moving chain or spindle!
Potential crushing and cutting areas between casement and Attention !
frame, dome light and support frame must be secured up to a
height of 2,50 m by safety measures which immediately stop
all movement in case of interference by personnel contact and
! Danger of damage
to drive and / or window
thus prevent any and all injury. These measures do not apply
to assembly in commercial and industrial facilities where access Routing of cable and electrical connections
and operation are limited exclusively to trained personnel. may only be performed by a qualified electrical company. Installation
must adhere to all applicable national regulations (e.g. DIN / VDE for
Assembly instructions Germany). If possible, seek agreement over cable specifications with
for professional assembly, installation and maintenance by quali- local approving authorities, electric power companies and occupation
fied and safety-conscious electricians and qualified technicians co-operative associations. Please note in particular:
trained in the assembly of electrical and mechanical drives. Read Install all low-voltage cables (24 V DC) separately from high-voltage
and heed all information in these assembly instructions and retain cables. Do not plaster flexible cables and ensure that freely suspen-
same for future use (maintenance). Reliable operation and avoi- ded cables are not under tension. Cables must be installed in such a
dance of damage and danger is only ensured by careful and way that they cannot be sheared off, twisted or kinked. Junction
thorough assembly and by making settings according to these boxes and external drive controls must be accessible for mainte-
instructions. Installing technicians are responsible for checking nance work. Cable type, cable length and cable cross section must
and adapting measurements on site as necessary. Ensure that comply with technical specifications / instructions. For maintenance
cables / wires are connected correctly. Adhere to maximum per- and repair, all 230 V system components must be disconnectable
missable drive voltage (see identification plate) and minimum / from the main power supply.
maximum power ratings (see technical data). It cannot be over- Maintenance and exchange of system components
emphasized that assembly and installation instructions are to be Before each maintenance or change in system configuration (e.g.
followed exactly. exchanging the drive), disconnect the system from all terminals of the
Never connect 24 V drives to a 230 V power supply ! main power supply and any back up batteries.
Danger to life ! Regular maintenance by a specialized and qualified company
Spare parts, attachments and controls (stipulated by law for SHEVS systems) is a prerequisite for ensuring
Operate this drive only with control units and brackets of the long term functionality and safety of the system. The operational
manufacturer. Use of third party products voids any and all readiness of the system must be checked on a regular basis.
liability, warranty and maintenance entitlements. Obtain only During maintenance, ensure that system components are free from
original spare parts or accessories from the manufacturer. any contamination. Check mounting devices and locking screws to
ensure that they are firmly secured. Test the opening and closing
Applications operation by conducting a trial run. The motor control drive is consi-
Suitable exclusively for automatic opening and closing of win- dered maintenance-free. Defective equipment may only be repaired
dows specified in assembly instructions. Consult manufacturer by us. Use only original spare parts of the manufacturer. A service
or his authorized distributor for further applications. contract is recommended for this purpose.
Always ensure that your system complies with currently valid After installation
regulations. Pay particular attention to the following: opening
and after any further changes to the system check all functions by
width of window, permissible dimensions for assembly and
means of a trial run. After final system completion the end user must
installation, opening time and opening speed, pressing force,
have been instructed concerning all important operating steps.
temperature resistance of drive and connecting cable and cross
section of connecting cable in relation to cable length and power Manufacturer’s declaration
consumption. Required mounting parts must be adapted to The drive including its control is manufactured and tested according
window type and supplemented appropriately if necessary. to European Regulations. A corresponding manufacturer’s declaration
All aggregates that are not specifically designed for operation has been submitted. You may only operate this drive if a Declaration
in damp / humid areas must be protected from dirt and moisture of Conformity exists for the entire system.
(see technical data). Total life-span
Application for bottom hung window Note: automatic operation (using natural climatic and ventilation
A chain drive requires the installation of a tilting safety arm to control) presupposes a total life-span of 10.000 ventilation cycles.
prevent damage to equipment and danger to personnel. Please Disposal
note: the safety arm must be adapted to the stroke length of the The drive contains electrical parts which must be disposed of in
drive (see technical data). That means that the opening width of accordance with national legal regulations.
safety arm must be greater than the stroke length of the drive in
order to avoid blockage.
121-80-0-9-8

aumüller aumatic gmbh


Steinerne Furt 58a • 86167 Augsburg
Tel.: 0821 / 270 93-0 • Fax: 0821 / 70 98 42
info@ferralux.de • www.aumueller-aumatic.de
121-80-0-9-1.6 AK 12.07