Sei sulla pagina 1di 1

Event Report

Date/Time Vert at 12:48:09 August 11, 2016 Serial Number BA18215 V 10.72-8.17 BlastMate III
Trigger Source Geo: 0.510 mm/s, Mic: 75.0 dB(A) Battery Level 6.0 Volts
Range Geo: 254 mm/s Unit Calibration September 9, 2014 by Absolute Instrument Systems
Record Time 7.75 sec (Auto=3Sec) at 1024 sps File Name T215GHWM.890
Job Number: 1 Scaled Distance 30.0 (300.0 m, 100.0 kg)
Notes
Location:PT PAMA PIT C2 Indonesian Standard SNI 7571:2010
Client:DB KIDECO ALL SECTION
254
User Name:agus bcn PQC DRIllBLAST 200
General: OB tanggul sump c3

9x10 100
7.0 meteran
Microphone 'A' Weight 50
Cl. 5
PSPL 76.8 dB(A) at 1.630 sec

Velocity (mm/s)
ZC Freq N/A
Channel Test Passed (Freq = 4.3 Hz Amp = 833 mv) 20 Cl. 4

ø
Tran Vert Long Cl. 3
10 ø x øøx
PPV 8.00 10.8 14.6 mm/s + øx+
+ ø+ xø + Cl. 2
ZC Freq 4.0 7.4 4.8 Hz + xx+øø ø
Time (Rel. to Trig) 1.215 1.250 1.005 sec 5 ø
+ ø x x Cl. 1
++ + ø ø x
Peak Acceleration 0.0795 0.0928 0.0663 g xø+ xø + ø x ø
x+ø + xx + x x
Peak Displacement 0.260 0.234 0.343 mm + x + ø x+ xxx + x
Sensor Check Passed Passed Passed 2 x xx+ x+x ø+ +
ø ø + +x
+ x + +ø
Frequency 7.4 7.6 7.3 Hz +ø x + ø +x +
Overswing Ratio 3.6 3.5 4.0 + ø ø ø ++ +øx ++ ø
xx ø xø
1
x
ø + x xx x + xø
Peak Vector Sum 15.3 mm/s at 1.005 sec 1 2 5 10 20 50 100 >
N/A: Not Applicable
Frequency (Hz)
Tran: + Vert: x Long: ø

Cl. 1 Historical/sensitive buildings


Cl. 2 Bad structure houses/without slope
Cl. 3 Medium structure houses/with slope
Cl. 4 Good struct. houses/frame struct.
*Cl. 5 Industrial buildings

MicA 0.0

Long 0.0

Vert 0.0

Tran 0.0

0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0

Time Scale: 0.50 sec/div Amplitude Scale:Geo: 5.00 mm/s/div Mic: 10.00 dB(A)/div Sensor Check
Trigger =

Printed: August 11, 2016 (V 10.10 - 10.10) Format (c) 2006-2010 Instantel, a division of Xmark Corporation