Technical Information for Carbon Monoxide Sensors
Figaro’s TGS5141 is a battery operable
electrochemical sensor which uses a unique
electrolyte that eliminates the need for a water
reservoir. By eliminating the water reservoir used
in TGS5042, the comparative size of TGS5141 is
reduced to just 10% of TGS5042. With its ultra
compact size, this sensor is the ideal choice for
size oriented applications such as portable CO
detectors, small residential CO detectors, and
multi-sensor fire detectors. OEM customers
will find individual sensor data printed on each
sensor in bar code form, enabling users to skip
the costly gas calibration process and allowing
for individual sensor tracking.
Specifications Page
Features..................................................................................................2
Applications...............................................................................................2
Structure...........................................................................................2
Basic Measuring Circuit...........................................................................2
Operating Conditions & Specifications...................................................3
Dimensions...................................................................................................3
Operation Principle......................................................................................................4
Basic Sensitivity Characteristics
Sensitivity to Various Gases............................................................5
Temperature and Humidity Dependency.............................................5
Gas Response Pattern.................................................................................6
Repeatability.............................................................................6
Influence of Storage...................................................................................6
Normal Operation Test.....................................................................................7
Sensitivity Test...................................................................................7
Reliability
Interference Gas Test......................................................................................8
Long-Term Stability................................................................................9
Corrosion Test...........................................................................................9
Variable Ambient Temperature Test................................................................9
Humidity Test.............................................................................................10
Stability Tests..................................................................................................11
Dust Test................................................................................................12
Marking..........................................................................................................................12
Cautions.......................................................................................................13
Appendix - Lead configuration............................................................................14
IMPORTANT NOTE: OPERATING CONDITIONS IN WHICH FIGARO SENSORS ARE USED WILL VARY
WITH EACH CUSTOMER’S SPECIFIC APPLICATIONS. FIGARO STRONGLY RECOMMENDS CONSULT-
ING OUR TECHNICAL STAFF BEFORE DEPLOYING FIGARO SENSORS IN YOUR APPLICATION AND,
IN PARTICULAR, WHEN CUSTOMER’S TARGET GASES ARE NOT LISTED HEREIN. FIGARO CANNOT
ASSUME ANY RESPONSIBILITY FOR ANY USE OF ITS SENSORS IN A PRODUCT OR APPLICATION FOR
WHICH SENSOR HAS NOT BEEN SPECIFICALLY TESTED BY FIGARO.
Revised 06/20 1
TECHNICAL INFORMATION FOR TGS5141-P00
1. Specifications
1-1 Features
1-3 Structure C1
TGS5141
installed inside the stainless steel cap. Counter
Vout
Revised 06/20 2
TECHNICAL INFORMATION FOR TGS5141-P00
Top view
Gas inlet
8.5±0.2
Working electrode
Bottom view
unit: mm
Figure 3 - Dimensions
Revised 06/20 3
TECHNICAL INFORMATION FOR TGS5141-P00
Air
Revised 06/20 4
TECHNICAL INFORMATION FOR TGS5141-P00
1.5
gases. The Y-axis shows output current (Iout/µA) in
each gas. The output current is linear to CO concen- 1.0
Note: The figures in this table are typical values and should not be used 2.0
as a basis for cross calibration. Cross sensitivity for various gases may
not be linear and should not be scaled. All data based on a 4 minute
exposure. For some gases, filter saturation and gas breakthrough may 1.5
1.0
I/Io
3-2 Temperature and humidity dependency
Figure 7a shows the temperature dependency of 0.5
Temperature dependency is based on the difference Figure 7a - Temperature dependency at 400ppm CO/50%RH
in the catalytic reaction rate on the electrodes, (Io=sensor output current at 20˚C)
and it can be simply compensated by utilizing a
thermistor. This linear relationship between I/
Io and CO concentration is constant regardless of 2.0
20˚C
CO concentration range, according to the sensor's 50˚C
Revised 06/20 5
TECHNICAL INFORMATION FOR TGS5141-P00
output signal when the sensor is placed into 30, 70, 0.8
0.8
Figure 9 shows the pattern of the output signal
when the sensor is repeatedly exposed to 400ppm 0.6
0.0
-0.2
0 500 1000 1500 2000
Time (sec.)
Revised 06/20 6
TECHNICAL INFORMATION FOR TGS5141-P00
0.5
0.0
0 5 10 15 20
Time (hrs.)
1.4
In addition, Figure 11b shows the CO sensitivity
1.2
characteristics of the sensor before, during, and
after the Normal Operation Test, demonstrating that 1.0
0.4
0.2
0.0
0 100 200 300 400 500 600 700
CO concentration (ppm)
0.8
as required by UL2034. Under this test, the sensor
was exposed to 30, 70, 150 and 400ppm of CO at 0.6
20˚C/40%RH. The period of exposure was varied
by concentration, corresponding with the maximum Iout(µA)
0.4
Revised 06/20 7
TECHNICAL INFORMATION FOR TGS5141-P00
0.2
0.0
4. Reliability 0 100 200 300 400 500
CO concentration (ppm)
0.02
13a (starting with CO 30ppm) for two hours, then
removing the sensor to fresh air for just one hour, 0.01
and followed by inserting the sensor into the next
gas. This procedure was repeated for the full range 0
r
Ai ppm pm pm pm pm ppm ppm m pm pm pm m m
of gases shown in Figure 13a. p p p p pp p
30 500 300 500 200 200 000 100 200 200 200 200
p p pp 0pp
3
O e e e e A 5 3 o l e e e O
C n an
ta
n at IP O2 n
NH tha olue tha
n n on C
ha t et C et
et Bu Hep l ac E T e Ac
Because the sensor is exposed to each of the test M
h y l o ro
Et ich
gases consecutively, to some small extent the effect Tr
Figure 13a - Interference gas test
of the previous test gas may affect subsequent tests (20˚C/40%RH)
for a short period. However, despite the short-term
effects of such gases remaining after exposure, the
sensor still shows significantly less sensitivity to 0.4
0.2
In addition, Figure 13b shows the CO sensitivity Before
After
characteristics of the sensor before and after this test, 0.2
Iout(µA)
Revised 06/20 8
TECHNICAL INFORMATION FOR TGS5141-P00
2.5
TGS5141. Test samples were stored in natural clean
air under a short-circuit condition and measured at 2.0
Revised 06/20 9
TECHNICAL INFORMATION FOR TGS5141-P00
1.0
sensor under UL2034. The sensor was exposed 20˚C/7%RH
Figure 17b shows data taken prior to the above test 1.2
at a constant relative humidity of 50%. These curves
represent the typical temperature dependency of 1.0
Revised 06/20 10
TECHNICAL INFORMATION FOR TGS5141-P00
Revised 06/20 11
TECHNICAL INFORMATION FOR TGS5141-P00
5. Marking
The two-dimensional bar code indicates the following
information:
xxxxnnnnnnnnnnnnnnnnnnnnnnnn
xxxx = sensor's sensitivity (slope) in numeric value as
determined by measuring the sensor's output in
300ppm of CO (Ex.1827=1.827nA/ppm)
nnnnnnnnnnnnnnnnnnnnnnnn = 24-digit
manufacturer's serial number Two-dimensional bar code
Revised 06/20 12
TECHNICAL INFORMATION FOR TGS5141-P00
Revised 06/20 13
TECHNICAL INFORMATION FOR TGS5141-P00
APPENDIX
TGS5141-P00 Lead Configuration
The height from the PCB to the sensor should be 0.6 mm Ni-plated
10.8±0.4
Side View SUS304
or more to ensure sufficient electrical insulation from the 4.0±0.1
PCB.
1.40±0.20 0.80±0.10 0.20±0.05 0.20±0.05
0.80±0.10 11.65±1.0
3.75±0.80
7.5±0.2
Counter electrode
Bottom View
Working electrode
Unit : mm
0.8 6.5±0.1
0.8
Enl
2.2
3.2
3.0
2.0
11.6±0.1
Note:
・Unspecified tolerance: ±0.05
0.8
Figure 23 - Recommended footprint 1.8
2.0
Revised 06/20 14
TECHNICAL INFORMATION FOR TGS5141-P00
FIGARO GROUP
Revised 06/20 15
TECHNICAL INFORMATION FOR TGS5141-P00
Revised 06/20 16