ENATEL | PRODUCT CATALOGUE
We are specialists in the design and manufacture of a range of standby power solutions for the telecom, networking, wireless and industrial markets. Enatel’s
smart power design offers intelligent solutions at an empowering price. In a market where only the fast survive, we respond quickly and cost-effectively so our
Offering a range of solutions from small standalone systems for applications like access nodes to medium systems for radio base stations for mobile networks and
larger systems for central office power applications. Our knowledge and experience of the global marketplace, along with our talented team, enable us to create
power supply solutions that meet each customer’s unique specifications no matter what volume they require.
We not only create our own suite of products, we also offer a comprehensive contract manufacturing service. Our highly flexible environment allows us to specialize
2U ULTRA COMPACT SYSTEM 1.0 - 6.0kW 48V DC ....................................... 9 DC-AC POWER SYSTEMS ........................................................................ 38
2U ULTRA COMPACT SYSTEM 1.0 - 8.0kW 48V DC ..................................... 10
2.0M LARGE DATA CENTER SOLUTIONS ...................................................... 22 FAN CONTROLLER BOARD ............................................................................ 50
WALL MOUNT SYSTEM 4.0kW 48V DC / 2.1kW 24V DC ............................... 23 BATTERY CONDITION MONITOR ................................................................... 51
AC MAINS MONITOR....................................................................................... 51
- World leading power density. Our DC power systems are designed to meet the requirements of
- Fully featured telecom telecommunications applications requiring high reliability and optimum
grade rectifiers. performance with easy expansion by way of hot pluggable modular rectifiers.
- Network monitoring available.
- Modular 19” design for ease They are the ideal solution for powering telecommunications and data networks
of installation.
requiring 24V, 48V or 60V DC. We offer a range of solutions for applications from
- Includes AC surge protection.
small standalone systems for applications like access nodes to medium sized
- More room for revenue
systems for radio base stations for mobile networks to larger systems for central
creating equipment.
office power applications.
- Upgrade existing systems
to higher power.
- High reliability means less cost Systems are configured using Enatel’s state of the art high frequency switch
of maintenance. mode rectifier modules, intelligent network capable controllers, AC & DC
- Full remote monitoring available distribution modules, and cabinets, and can be customized and configured to
means less site visits and less cost. meet individual customer requirements.
- Cost competitive.
- Suitable for more harsh For details on a Enatel power system that meets your requirements contact us.
environments.
48
AC Input: Single phase.
DC Output
Nominal Voltage:
Polarity:
-48V
DC Distribution:
Breaker Fail Detection: Electronic fail detection on both load and battery breakers.
Low Voltage Disconnect: 50A battery LVD (magnetically latching) fitted as standard.
Mechanical
Dimensions, W,H,D: 482.6mm (standard 19” module), also fits ETSI 515mm mounting cabinet,
Monitoring & Control: Various monitoring options are available via the Enatel SM35/36 series
Accessories
ACA-BC08P2: 2m, 8mm Ø battery cable kit. (other lengths available to special order)
48
AC Input: Single phase. (refer to RM series brochures for full details)
DC Output
4.0
Nominal Voltage: -48V (+24V available to special order)
Rated System Output Power: 4000W @ -48V (2000W @ -48V. Low power option.)
kW DC Distribution:
maximum output power. Load: 1x 63A load circuit breaker.
Breaker Fail Detection: Electronic fail detection on both load and battery breakers.
Mechanical
Dimensions, W, H, D: 482.6mm (standard 19” module), 44.45mm (1U, 1¾”), 350mm (13¾”)
Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of
three voltage-free relay alarm outputs. Options include extension I/O PCBs
relay outputs. For further details, refer to the SM30 series of brochures.
48
AC Input: Single phase. (refer to RM series brochures for full details)
Frequency Range: 45-66Hz
Power Factor: >0.99 (full load)
Termination: Single phase, 6mm² L, N, E tunnel terminals. V
nominal output voltage.
DC Output
4.0
Nominal Voltage: -48V, -60V (+24V available to special order)
Rated System Output Power: 4000W @ -48V (2000W @ -48V. Low power option.)
Polarity: Positive earth. (negative earth available to special order)
DC Distribution:
kW
Load: 3x 20A load circuit breakers.
maximum output power.
(3x 10A load circuit breakers. Low power option.)
Battery: 2x 30A battery circuit breakers.
(2x 20A battery circuit breakers. Low power option.) Supervisory Module
SM32
ULTRA
compact
Breaker Fail Detection: Electronic fail detection on both load and battery breakers.
DC Terminals:
Live: Tunnel terminals, 6mm²
Common: Tunnel terminals, 6mm²
Low Voltage Disconnect: 80A battery LVD fitted as standard.
(50A battery LVD fitted as standard. Low power option.)
Mechanical
Dimensions, W, H, D: 482.6mm (standard 19” module), 44.45mm (1U, 1¾”), 350mm (13¾”)
Weight: 5kg (excluding rectifier modules)
Shipping Dimensions, W, H, D: 540mm, 95mm, 400mm
Weight: 6kg (excluding rectifier modules)
Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of
control & supervisory modules. Standard features include full temperature
compensation, automated and manual battery testing/equalisation and
three voltage-free relay alarm outputs. Options include extension I/O PCBs
that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free
relay outputs. For further details, refer to the SM30 series of brochures.
48
AC Input: Three phase or single phase. (refer to RM series brochures for full details)
Frequency Range: 45-66Hz
Power Factor: >0.99 (full load)
V Termination: Three phase, 6mm² L1, L2, L3, N, E tunnel terminals.
nominal output voltage. (Single phase by linking L1, L2, L3 terminals)
6.0
DC Output
Nominal Voltage: -48V, -60V (+24V available to special order)
Rated System Output Power: 6000W @ -48V (3000W @ -48V. Low power option)
Polarity: Positive earth. (negative earth available to special order)
kW DC Distribution:
maximum output power. Load: 2x 10A, 2x 20A, 2x 32A load circuit breakers.
(2x 6A, 2x 10A, 2x 20A load circuit breakers. Low power option.)
Battery: 2x 63A battery circuit breakers.
Load Load Load Battery ULTRA
compact
(2x 63A battery circuit breakers. Low power option.)
Breaker Fail Detection: Electronic fail detection on both load and battery breakers.
Supervisory Module
SM32
DC Terminals:
Load: Tunnel terminals, 16mm² (rear connected)
Battery: Tunnel terminals, 35mm² (rear connected)
Low Voltage Disconnect: 125A battery LVD fitted as standard. (magnetically latching contactor)
(80A battery LVD fitted as standard. Low power option)
Mechanical
Dimensions, W, H, D: 482.6mm (standard 19” module), 89mm (2U, 3½”),
350mm (13¾”) (390mm with cable strain relief)
Weight: 9kg (excluding rectifier modules)
Shipping Dimensions, W, H, D: 540mm, 150mm, 435mm
Weight: 10.5kg (excluding rectifier modules)
Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of
control & supervisory modules. Standard features include full temperature
compensation, automated and manual battery testing/equalisation and
three voltage-free relay alarm outputs. Options include extension I/O PCBs
that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free
relay outputs. For further details, refer to the SM30 series of brochures.
48
AC Input: Three phase or single phase. (refer to RM series brochures for full details)
Frequency Range: 45-66Hz
Power Factor: >0.99 (full load)
Termination: Three phase, 6mm² L1, L2, L3, N, E tunnel terminals. V
(Single phase by linking L1, L2, L3 terminals) nominal output voltage.
DC Output
6.0
Nominal Voltage: -48V, -60V (+24V available to special order)
Rated System Output Power: 6000W @ -48V (3000W @ -48V. Low power option.)
Polarity: Positive earth. (negative earth available to special order)
DC Distribution:
kW
Load: 8x 10A, 4x 20A, 4x 30A load circuit breakers.
maximum output power.
(8x 6A, 4x 10A, 4x 20A load circuit breakers. Low power option.)
Battery: 2x 100A battery circuit breakers.
(2x 50A battery circuit breakers. Low power option.)
Breaker Fail Detection: Electronic fail detection on both load and battery. breakers
ULTRA
Battery compact
Supervisory Module
Load: 10A, 6mm² tunnel terminals. 20A & 30A, 10mm² tunnel terminals.
(6A & 10A, 6mm² tunnel terminals.
20A, 10mm² tunnel terminals. Low power option.)
Battery: 100A, 35mm² tunnel terminals.
(50A, 16mm² tunnel terminals. Low power option.)
Low Voltage Disconnect: 125A battery LVD fitted as standard.
(80A battery LVD fitted as standard. Low power option.)
Mechanical
Dimensions, W, H, D: 482.6mm (standard 19” module), 89mm (2U, 3½”),
350mm (13¾”) (390mm with cable strain relief)
Weight: 9kg (excluding rectifier modules)
Shipping Dimensions, W, H, D: 540mm, 150mm, 435mm
Weight: 10.5kg (excluding rectifier modules)
Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of
control & supervisory modules. Standard features include full temperature
compensation, automated and manual battery testing/equalisation and
three voltage-free relay alarm outputs. Options include extension I/O PCBs
that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free
relay outputs. For further details, refer to the SM30 series of brochures.
48
AC Input: Three phase or single phase. (refer to RM series brochures for full details)
8.0
DC Output
DC Distribution:
ULTRA
Load Load Battery compact
DC Terminals:
Low Voltage Disconnect: 150A battery LVD fitted as standard. (magnetically latching contactor)
Mechanical
Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of
three voltage-free relay alarm outputs. Options include extension I/O PCBs
relay outputs. For further details, refer to the SM30 series of brochures.
48
AC Input: Three phase or single phase. (refer to RM series brochures for full details)
DC Output
Nominal Voltage:
Polarity:
-48V, -60V (+24V available to special order)
6000W @ -48V
DC Distribution:
3 S
Supervisory Module
SM32
Breaker Fail Detection: Electronic fail detection on both load and battery breakers.
Mechanical
Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of
three voltage-free relay alarm outputs. Options include extension I/O PCBs
relay outputs. For further details, refer to the SM30 series of brochures.
48
AC Input: Three phase or single phase. (refer to RM series brochures for full details)
6.0
Proctection: 20A circuit breaker provided per rectifier.
DC Output
DC Distribution:
3 S
3
2 Battery: 2x 100A battery circuit breakers.
Supervisory Module
SM32
Breaker Fail Detection: Electronic fail detection on both load and battery breakers.
Mechanical
Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of
three voltage-free relay alarm outputs. Options include extension I/O PCBs
relay outputs. For further details, refer to the SM30 series of brochures.
supervisory module.
48
AC Input: Three phase or single phase. (refer to RM series brochures for full details)
8.0
(Three phase without surge protection available to special order)
DC Output
S 3
2
M
Breaker Fail Detection: Electronic fail detection on both load and battery breakers.
Mechanical
Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of
three voltage-free relay alarm outputs. Options include extension I/O PCBs
relay outputs. For further details, refer to the SM30 series of brochures.
supervisory module.
48
AC Input: Three phase (refer to RM series brochures for full details)
14.0
maximum output power.
kW
DC Output
Nominal Voltage:
Polarity:
-48V, -60V (+24V available to special order)
14000W @ -48V DC
DC Distribution:
S
Supervisory Module
SM32
Breaker Fail Detection: Electronic fail detection on both load and battery breakers.
Mechanical
Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of
three voltage-free relay alarm outputs. Options include extension I/O PCBs
free relay outputs. For further details, refer to the SM30 series of brochures.
48
AC Input: Three phase. (refer to RM series brochures for full details)
14.0
DC Output
Breaker Fail Detection: Electronic fail detection on both load and battery breakers. 2 3 2 3 2 3
DC Terminals:
Supervisory Module
SM32
Low Voltage Disconnect: 300A battery LVD fitted as standard. (option 2x LVDs)
Mechanical
Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of
three voltage-free relay alarm outputs. Options include extension I/O PCBs
relay outputs. For further details, refer to the SM30 series of brochures.
48
AC Input: Three phase (refer to RM series brochures for full details)
14.0
DC Output
DC Distribution:
2 3 Breaker Fail Detection: Electronic fail detection on both load and battery breakers
DC Terminals:
Supervisory Module
SM32
Mechanical
Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of
three voltage-free relay alarm outputs. Options include extension I/O PCBs
relay outputs. For further details, refer to the SM30 series of brochures.
48
AC Input: Three phase. (refer to RM series brochures for full details)
Frequency Range: 45-66Hz
Power Factor: >0.99 (full load)
Termination: Three phase L1, L2, L3, N, E 10mm² terminal blocks. V
Surge protection. (40kA 8/20msec) nominal output voltage.
22.0
DC Output
Nominal Voltage: -48V, -60V (+24V available to special order)
Rated System Output Power: 22000W @ -48V DC
Polarity: Positive earth. (negative earth available to special order)
DC Distribution:
kW
maximum output power.
Load: 2x 20A, 4x 32A, 4x 63A load circuit breakers.
Battery: 4x 100A battery circuit breakers.
Breaker Fail Detection: Electronic fail detection on both load and battery breakers. S
Supervisory Module
Mechanical
Dimensions, W, H, D: 482.6mm (standard 19” module), 266.7mm (6U, 10½”),
350mm (13¾”) (390mm with cable strain relief)
Weight: 21kg (excluding rectifier modules)
Shipping Dimensions, W, H, D: 540mm, 350mm, 435mm
Weight: 30kg (excluding rectifier modules)
Monitoring & Control: Various monitoring options are available via the Enatel SM30 series of
control & supervisory modules. Standard features include full temperature
compensation, automated and manual battery testing/equalisation and
three voltage-free relay alarm outputs. Options include extension I/O PCBs
that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free
relay outputs. For further details, refer to the SM30 series of brochures.
48
AC Input
AC Input Range: 312-500V AC (full power output)
156-312V AC (reduced output power)
27.0
Surge Protection: MOV; 3x Ph-N, 1x N-Earth.
In(8/20μS): 20kA
Imax(8/20μS): 40kA
kW
DC Output
maximum output power.
Nominal System Output Voltage: -48V
Maximum Power Output: 27000W
Polarity: Positive earth. (standard)
Load & Battery Distribution: 16x load positions for 18mm wide circuit breakers,
plus 4x battery breakers up to 125A each.
May be arranged in different configurations of load and battery
breakers. Fuse options also available. (options)
Low Voltage Disconnect Options: Single battery LVD fitted as standard.
Up to 2x LVDs with independent control may
be fitted on battery or load side. (option)
LVD Current Rating: 600A
Supervisory & Monitoring Module: SM31 (standard) SM32 TCP/IP enabled for
web based viewing & configuration. (option)
Supervisory Module Mounting: Door mounted for improved system terminal access.
Battery Condition Monitoring: Optional full battery monobloc monitoring.
(bloc voltage & string current)
Alarms (voltage free contacts): 1x fixed alarm - “Monitor failed”
Up to 9x user configurable, 2 of which are pre-programmed:
- Non-urgent summary alarm
- Urgent summary alarm
7x unassigned, may be assigned to any one of 37 alarm events,
(e.g. rectifier fail, mains fail etc.) on an “AND” or “OR” basis
Contacts rated for 1A at 60V DC
Environmental Requirements
Temperature: -10°C to +70°C (max. power de-rated above 50°C)
Humidity: 5-95% RH (non-condensing)
Altitude: <2500m, De-rate maximum ambient temperature
by 4°C per 1000m above sea level.
Mechanical
Dimensions W, D, H: 600mm (23 ½”) , 19” standard mounting rails 450mm (17 ¾”),
800mm (31 ½”) providing 15U of rack space.
Weight: 75kg (approx)
Shipping Size L, W, H 900mm x 700mm x 550mm
Shipping weight: 80kg (approx)
Compliances
Safety: EN60950
48
AC Input
AC Input Range: 312-500V AC (full power output)
156-312V AC (reduced output power)
Maximum Input Current: 54A/ph (ph-N) V
Frequency Range: 45-66Hz nominal output voltage.
Power Factor: >0.99 (full power)
Style: 3-phase neutral and earth.
27.0
Surge Protection: MOV; 3x Ph-N, 1x N-Earth. (spark gap)
In(8/20μS): 20kA
Imax(8/20μS): 40kA
kW
DC Output
maximum output power.
Nominal System Output Voltage: -48V
Maximum Power Output: 27000W
Polarity: Positive earth. (standard)
Load Distribution:
Priority: 6x 18mm MCBs.
Non-Priority: 5x 18mm MCBs, 2x 100A DIN00 fuses, 2x 160A DIN00 fuses.
Battery Distribution: 2x 400A DIN02 fuses.
LVD Options: 2x LVDs with independent control on load side.
LVD Rating:
Priority: 400A
Non-Priority: 200A
Supervisory & Monitoring Module: SM31 (standard) SM32 TCP/IP enabled for
web based viewing & configuration. (option)
Supervisory Module Mounting: Door mounted for improved system terminal access.
Battery Condition Monitoring: Optional full battery monobloc monitoring.
(bloc voltage & string current)
Alarms (voltage free contacts): 1x fixed alarm – “Monitor failed”
Up to 9x user configurable, 2 of which are pre-programmed:
- Non-urgent summary alarm
- Urgent summary alarm
7x unassigned, may be assigned to any one of 37 alarm events,
(e.g. rectifier fail, mains fail etc.) on an “AND” or “OR” basis.
Contacts rated for 1A at 60V DC
Environmental Requirements
Temperature: -10°C to +70°C (max. power de-rated above 50°C)
Humidity: 5-95% RH (non-condensing)
Altitude: <2500m, De-rate maximum ambient temperature
by 4°C per 1000m above sea level.
Mechanical
Dimensions W, D, H: 600mm (23.6”), 600mm (23.6”), 1600mm (63”),
providing 33U of rack space.
Weight: 120kg (approx)
Shipping Size L, W, H 1700mm x 720mm x 830mm
Shipping weight: 130kg (approx)
Compliances
Safety: EN60950
48
AC Input
Voltage Range: 312-500V AC (full power output)
156-312V AC (reduced output power)
54.0
Style: 3-phase neutral and earth.
Surge Protection: MOV; 3x Ph-N, 1x N-Earth.
In(8/20μS): 20kA
Imax(8/20μS): 40kA
kW
maximum output power. DC Output
Nominal System Output Voltage: -48V
Maximum Power Output: 54000W
Polarity: Positive earth. (standard)
Load & Battery Distribution: 56x positions for 18mm wide DIN rail mount circuit breakers.
May be arranged in many configurations of loads and batteries.
Fuse options also available. (options)
Low Voltage Disconnect Options: Single battery LVD fitted as standard.
Up to 2x LVDs with independent control
may be fitted on battery or load side. (option)
LVD Current Rating: 1200A
Supervisory & Monitoring Module: SM31 (standard) SM32 TCP/IP enabled
for web based viewing & configuration. (option)
Supervisory Module Mounting: Door mounted for improved system terminal access.
Battery Condition Monitoring: Optional full battery monobloc monitoring.
(bloc voltage & string current)
Alarms (voltage free contacts): 1x fixed alarm – “Monitor failed”
Up to 9x user configurable, 2 of which are pre-programmed:
- Non-urgent summary alarm
- Urgent summary alarm
7x unassigned, may be assigned to any one of 37 alarm events,
(e.g. rectifier fail, mains fail etc.) on an “AND” or “OR” basis
Contacts rated for 1A at 60V DC
Environmental Requirements
Temperature: -10°C to +70°C (max. power de-rated above 50°C)
Humidity: 5-95% RH (non-condensing)
Altitude: <2500m, De-rate maximum ambient temperature
by 4°C per 1000m above sea level.
Mechanical
Dimensions W, D, H: 600mm (23.6”), 19” standard mounting rails, 600mm (23.6”),
2000mm (78 ¾”) 40U of rack space.
Weight: 180kg (approx)
Shipping Size L, W, H 2100mm, 720mm, 830mm
Shipping weight: 195kg (approx)
Compliances
Safety: EN60950
48
AC Input
16.0
Style: 3-phase neutral and earth.
Surge Protection: MOV; 3x Ph-N, 1x N-Earth. (spark gap)
In(8/20μS): 20kA
Imax(8/20μS): 40kA
kW
maximum output power.
DC Output
Nominal System Output Voltage: -48V
Low Voltage Disconnect Options: Single battery LVD fitted as standard. Up to 2x LVDs with
Environmental Requirements
Temperature: -10°C to +70°C (max. power de-rated above 50°C)
Humidity: 5-95% RH (non-condensing)
Altitude: <2500m, De-rate maximum ambient temperature
by 4°C per 1000m above sea level.
Mechanical
Dimensions W, D, H: 600mm (23.6”), 600mm (23.6”),2200mm (86.6”)
Weight: 1000kg when fitted with 4x strings of 180Ahr batteries. (approx)
Shipping Size L, W, H 2400mm x 720mm x 830mm
Shipping weight: 180kg (no batteries fitted, approx)
Battery Accommodation
Battery Trays: Up to 4x 180Ahr monoblocs of up to 60kg each per tray.
(max. of 250kg per tray)
Battery Monobloc Size W, D, H: 110mm, 555mm, 288mm
Compliances
Safety: EN60950
48
AC Input
Voltage Range: 312-500V AC (full power output)
156-312V AC (reduced output power)
Maximum Input Current: 120A/ph (ph-N)
V Frequency Range: 45-66Hz
nominal output voltage. Power Factor: >0.99 (full power)
Style: 3-phase neutral and earth.
54.0
Surge Protection: MOV; 3x Ph-N, 1x N-Earth.
In(8/20μS): 20kA
Imax(8/20μS): 40kA
kW DC Output
Nominal System Output Voltage: -48V
scalable output power.
Maximum Power Output: From 54000W scalable to over 300kW.
Polarity: Positive earth. (standard)
Environmental Requirements
Temperature: -10°C to +70°C (max. power
de-rated above 50°C)
Humidity: 5-95% RH (non-condensing)
Altitude: <2500m, De-rate maximum
ambient temperature by 4°C
per 1000m above sea level.
Mechanical
Dimensions W, D, H: 600mm (23.6”), 19” standard
mounting rails, 600mm (23.6”),
2000mm (78 ¾”)
40U of rack space.
Weight: 180kg (approx)
Shipping Size L, W, H 2100mm, 720mm, 830mm
Shipping weight: 195kg (approx)
Compliances
Safety: EN60950
48
AC Input: Single phase with surge protection and input 32A MCB
terminals.
4.0
DC Output Nominal Voltages: -48V version. +24V version.
Max Rated System Output Power: 4000W @ -48V DC, 83A max. 2140W @ +24V DC, 80A max.
24
DC Distribution:
2.1
Load: Common: 16mm tunnel terminals.
Low Voltage Disconnect: 80A battery LVD fitted as standard on -48V and 24V systems.
Monitoring and Control: Various monitoring options via the Enatel SM30 series of control
- Force cooled. If you are looking for modular, plug and play rectifiers with some of the highest
- Microprocessor controlled. power densities in the market you have come to the right place.
- Power factor corrected.
- Thermally protected. These rectifiers are designed for integration into systems that require intelligent
- Input/output voltage features and remote control. With efficiencies in excess of 92% and power
and current protected.
factors of greater than 0.98 these rectifiers will save operating costs, and reduce
- Serial alarm and control interface.
heat dissipation.
48
AC Input
Nominal: 230V
Voltage Range: 90-300V (reduced power below 175V)
Frequency Range: 45-65 Hz
Power Factor: >0.99
V
Efficiency: >92% (>45% output power) nominal output voltage.
Input Fuses: HRC fuses in phase and neutral.
3.0
Maximum Input Current: 19A
Protection:
Input Voltage: Auto shutdown, auto restart when correct voltage restored.
Input Inrush: <2x maximum input current.
DC Output kW
Output Ratings: Constant power output from 50V to 58V nominal output power.
Nominal Voltage: 48V
60.0
Rated Voltage: 58V
Voltage Range: 43-60V
Maximum Current: 60A
Regulation:
Line: ±0.1%
Load: ±0.5% (no load to full load) A
Hold-up Time: >15ms for 20% output voltage drop. maximum output current.
Start-up Time: Start up delay 1 second. (varies with AC supply voltage)
Walk-in delay 6 seconds at full output. (varies with DC output voltage)
Protection:
Current Limit: Adjustable to 50-100% of maximum rated current.
Over Temperature: Automatic current turndown, backup shutdown protection.
Polarity Reversal: Output fuse with crowbar diode.
Over voltage: Adjustable limit.
Noise: (under nominal conditions)
Ripple <100Hz: <1mV rms unweighted
Voice band 100Hz-5KHz: <1mV rms psophometric
Wide band 5kHz-1MHz: <5mV rms unweighted
Peak to Peak 0-20MHz: <50mV peak to peak
Isolation:
Input to Output: 4000V DC
Input to Chassis: 3500V DC (VDR to chassis removed)
Output to Chassis: 2100V DC
Environmental Requirements
Ambient Temperature:
Nominal: 25+/-5ºC
Range: -10ºC to +70ºC (maximum output power is derated above +50ºC)
Storage Temperature: -20ºC to +70ºC
Humidity: 5-95% RH (non-condensing)
Altitude: <2500m, De-rate maximum ambient temperature by 4ºC per 1000m above sea level.
Mechanical
Dimensions, W, H, D: 41mm, 220mm, 305mm overall.
Weight: 2.7kg
Shipping Dimensions W, H, D: 52mm, 230mm, 340mm
Shipping Weight: 2.85kg
Cooling: Forced cooled, using dual temperature controlled high reliability fans.
Compliances
Safety: EN60950
Electrostatic Discharge: CISPR24
Radiated Radio Frequency: CISPR22
AC Harmonics: EN61000-3-2
AC Flicker and Fluctuation: EN61000-3-3
Other: CE & RoHS compliant.
48
AC Input
Nominal: 230V
Voltage Range: 90-300V (reduced power below 175V)
Frequency Range: 45-65 Hz
V Power Factor: >0.99
nominal output voltage. Efficiency: >92% (>45% output power)
Input Fuses: HRC fuses in phase and neutral.
3.0
Maximum Input Current: 19A
Protection:
Input Voltage: Auto shutdown, auto restart when correct voltage restored.
Input Inrush: <2x maximum input current.
24
Voltage Range: 43-60V 21-30V
Maximum Current: 60A 60A
Regulation:
Line: ±0.1%
1.7
Protection:
Current Limit: Adjustable to 50-100% of maximum rated current.
Over Temperature: Automatic current turndown, backup shutdown protection.
Polarity Reversal: Output fuse with crowbar diode.
Over voltage: Adjustable limit.
kW Noise: (under nominal conditions)
nominal output power. Ripple <100Hz: <1mV rms unweighted
Voice band 100Hz-5KHz: <1mV rms psophometric
60.0
Wide band 5kHz-1MHz: <5mV rms unweighted
Peak to Peak 0-20MHz: <50mV peak to peak
Isolation:
Input to Output: 4000V DC
Input to Chassis: 3500V DC (VDR to chassis removed)
A Output to Chassis: 2100V DC
maximum output current.
Environmental Requirements
Ambient Temperature:
Nominal: 25+/-5ºC
Range: -10ºC to +70ºC (maximum output power is derated above +50ºC)
Storage Temperature: -20ºC to +70ºC
Humidity: 5-95% RH (non-condensing)
Altitude: <2500m, De-rate maximum ambient
temperature by 4ºC per 1000m above sea level.
Mechanical
Dimensions, W, H, D: 41mm, 220mm, 305mm overall.
Weight: 2.7kg
Shipping Dimensions W, H, D: 52mm, 230mm, 340mm
Shipping Weight: 2.85kg
Cooling: Forced cooled, using dual temperature controlled high reliability fans.
Compliances
Safety: EN60950
Electrostatic Discharge: CISPR24
Radiated Radio Frequency: CISPR22
AC Harmonics: EN61000-3-2
AC Flicker and Fluctuation: EN61000-3-3
Other: CE & RoHS compliant.
60/48
AC Input
Nominal: 230V
Voltage Range: 90-300V (reduced power below 175V)
Frequency Range: 45-65 Hz
Power Factor: >0.99 V
Efficiency: >92% (>45% output power) nominal output voltage.
Input Fuses: HRC fuses in phase and neutral.
Maximum Input Current: 19A
3.0
Protection:
Input Voltage: Auto shutdown, auto restart when correct voltage restored.
Input Inrush: <2x maximum input current.
50.0
Voltage Range: 52-74V 43-60V
Maximum Current: 50A 50A
Regulation:
Line: ±0.1%
Load: ±0.5% (no load to full load) A
Hold-up Time: >15ms for 20% output voltage drop maximum output current.
Start-up Time: Start up delay 1 second. (varies with AC supply voltage)
Walk-in delay 6 seconds at full output. (varies with DC output voltage)
Protection:
Current Limit: Adjustable to 50-100% of maximum rated current.
Over Temperature: Automatic current turndown, backup shutdown protection.
Polarity Reversal: Output fuse with crowbar diode.
Over voltage: Adjustable limit.
Noise: (under nominal conditions)
Ripple <100Hz: <1mV rms unweighted
Voice band 100Hz-5KHz: <1mV rms psophometric
Wide band 5kHz-1MHz: <5mV rms unweighted
Peak to Peak 0-20MHz: <50mV peak to peak
Isolation:
Input to Output: 4000V DC
Input to Chassis: 3500V DC (VDR to chassis removed)
Output to Chassis: 2100V DC
Environmental Requirements
Ambient Temperature:
Nominal: 25+/-5ºC
Range: -20ºC to +70ºC (maximum output power is derated above +50ºC)
Storage Temperature: -20ºC to +70ºC
Humidity: 5-95% RH (non-condensing)
Altitude: <2500m, De-rate maximum ambient temperature
by 4ºC per 1000m above sea level.
Mechanical
Dimensions, W, H, D: 41mm, 220mm, 305mm overall.
Weight: 2.8kg
Shipping Dimensions W, H, D: 52mm, 230mm, 340mm
Shipping Weight: 2.95kg
Cooling: Forced cooled, using dual temperature controlled high reliability fans.
Compliances
Safety: EN60950
Electrostatic Discharge: CISPR24
Radiated Radio Frequency: CISPR22
AC Harmonics: EN61000-3-2
AC Flicker and Fluctuation: EN61000-3-3
Other: CE & RoHS compliant.
24
AC Input
Nominal: 230V
Voltage Range: 90-300V (reduced power below 150V)
Frequency Range: 45-65 Hz
V Power Factor: >0.99
nominal output voltage. Efficiency: >91% (>45% output power)
Input Fuses: HRC fuses in phase and neutral.
2.3
Maximum Input Current: 19A
Protection:
Input Voltage: Auto shutdown, auto restart when correct voltage restored.
Input Inrush: <2x maximum input current.
kW DC Output
nominal output power. Output Ratings: Current limited to 80A
Nominal Voltage: 24V
Rated Voltage: 29V
80.0
Voltage Range: 21-30V
Maximum Current: 80A
Regulation:
Line: ±0.1%
Environmental Requirements
Ambient Temperature:
Nominal: 25+/-5ºC
Range: -10ºC to +70ºC (maximum output power is derated above +50ºC)
Storage Temperature: -20ºC to +70ºC
Humidity: 5-95% RH (non-condensing)
Altitude: <2500m, De-rate maximum ambient temperature
by 4ºC per 1000m above sea level.
Mechanical
Dimensions, W, H, D: 41mm, 220mm, 305mm overall.
Weight: 2.7kg
Shipping Dimensions W, H, D: 52mm, 230mm, 340mm
Shipping Weight: 2.75kg
Cooling: Forced cooled, using dual temperature controlled high reliability fans.
Compliances
Safety: EN60950
Electrostatic Discharge: CISPR24
Radiated Radio Frequency: CISPR22
AC Harmonics: EN61000-3-2
AC Flicker and Fluctuation: EN61000-3-3
Other: CE & RoHS compliant.
48
AC Input
Nominal: 230V
Voltage Range: 90-300V (reduced power below 175V)
Frequency Range: 45-65 Hz
Power Factor: >0.99 V
Efficiency: >92% (>50% output power) nominal output voltage.
Total Harmonic Distortion (THD): <5% (>30% output power)
Input Fuses: HRC fuses in phase and neutral.
2.0
Maximum Input Current: 12A
Protection:
Input Voltage: Auto shutdown, auto restart when correct voltage restored.
Input Inrush: <12A rms
kW
DC Output
nominal output power.
Output Ratings: Constant power output from 48V to 58V
Nominal Voltage: 48V
41.7
Rated Voltage: 58V
Voltage Range: 43-60V
Maximum Current: 41.7A
Regulation:
Line: ±0.1%
Load: ±0.5% (no load to full load)
A
Hold-up Time: >15ms for 20% output voltage drop. maximum output current.
Start-up Time: Start up delay 1 second. (varies with AC supply voltage)
Walk-in delay 6 seconds at full output. (varies with DC output voltage)
Protection:
Current Limit: Adjustable to 50-100% of maximum rated current.
Over Temperature: Automatic current turndown, backup shutdown protection.
Polarity Reversal: Output fuse with crowbar diode.
Over voltage: Adjustable limit.
Noise: (under nominal conditions)
Ripple <100Hz: <1mV rms unweighted
Voice band 100Hz-5KHz: <1mV rms psophometric
Wide band 5kHz-1MHz: <5mV rms unweighted
Peak to Peak 0-20MHz: <100mV peak to peak
Isolation:
Input to Output: 4000V DC
Input to Chassis: 3500V DC (VDR to chassis removed)
Output to Chassis: 2100V DC
Environmental Requirements
Ambient Temperature:
Nominal: 25+/-5ºC
Range: -10ºC to +70ºC (maximum output power is derated above +50ºC)
Storage Temperature: -20ºC to +70ºC
Humidity: 5-95% RH (non-condensing)
Altitude: <2500m, De-rate maximum ambient temperature
by 4ºC per 1000m above sea level.
Mechanical
Dimensions, W, H, D: 111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)
Weight: 1.5kg
Shipping Dimensions W, H, D: 120mm, 52mm, 325mm
Shipping Weight: 1.6kg
Cooling: Forced cooled.
Compliances
Safety: EN60950
Electrostatic Discharge: CISPR24
Radiated Radio Frequency: CISPR22
AC Harmonics: EN61000-3-2
AC Flicker and Fluctuation: EN61000-3-3
Other: CE & RoHS compliant.
48
AC Input
Nominal: 230V
Voltage Range: 90-300V (reduced power below 175V)
Frequency Range: 45-65 Hz
V Power Factor: >0.99
nominal output voltage. Efficiency: >91% (>50% output power)
Input Fuses: HRC fuses in phase and neutral.
2.0
Maximum Input Current: 13A
Protection:
Input Voltage: Auto shutdown, auto restart when correct voltage restored.
Input Inrush: <2x maximum input current.
24
Voltage Range: 43-60V 21-30V
Maximum Current: 41.7A 41.7A
Regulation:
Line: ±0.1%
1.0
Protection:
Current Limit: Adjustable to 50-100% of maximum rated current.
Over Temperature: Automatic current turndown, backup shutdown protection.
Polarity Reversal: Output fuse with crowbar diode.
Over voltage: Adjustable limit.
kW Noise: (under nominal conditions)
nominal output power. Ripple <100Hz: <1mV rms unweighted
Voice band 100Hz-5KHz: <1mV rms psophometric
41.7
Wide band 5kHz-1MHz: <5mV rms unweighted
Peak to Peak 0-20MHz: <50mV peak to peak
Isolation:
Input to Output: 4000V DC
Input to Chassis: 3500V DC (VDR to chassis removed)
A Output to Chassis: 2100V DC
maximum output current.
Environmental Requirements
Ambient Temperature:
Nominal: 25+/-5ºC
Range: -10ºC to +70ºC (maximum output power is derated above +50ºC)
Storage Temperature: -20ºC to +70ºC
Humidity: 5-95% RH (non-condensing)
Altitude: <2500m, De-rate maximum ambient temperature
by 4ºC per 1000m above sea level.
Mechanical
Dimensions, W, H, D: 111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)
Weight: 1.5kg
Shipping Dimensions W, H, D: 120mm, 52mm, 325mm
Shipping Weight: 1.6kg
Cooling: Forced cooled.
Compliances
Safety: EN60950
Electrostatic Discharge: CISPR24
Radiated Radio Frequency: CISPR22
AC Harmonics: EN61000-3-2
AC Flicker and Fluctuation: EN61000-3-3
Other: CE & RoHS compliant.
60/48
AC Input
Nominal: 230V
Voltage Range: 90-300V (reduced power below 175V)
Frequency Range: 45-65 Hz
Power Factor: >0.99 V
Efficiency: >91% (>50% output power) nominal output voltage.
Input Fuses: HRC fuses in phase and neutral.
1.8
Maximum Input Current: 11A
Protection:
Input Voltage: Auto shutdown, auto restart when correct voltage restored.
Input Inrush: <2x maximum input current.
30.0
Voltage Range: 52-74V 43-60V
Maximum Current: 30A 30A
Regulation:
Line: ±0.1%
Load: ±0.5% (no load to full load) A
Hold-up Time: >15ms for 20% output voltage drop
maximum output current.
Start-up Time: Start up delay 1 second. (varies with AC supply voltage)
Walk-in delay 6 seconds at full output. (varies with DC output voltage)
Protection:
Current Limit: Adjustable to 50-100% of maximum rated current.
Over Temperature: Automatic current turndown, backup shutdown protection.
Polarity Reversal: Output fuse with crowbar diode.
Over voltage: Adjustable limit.
Noise: (under nominal conditions)
Ripple <100Hz: <1mV rms unweighted
Voice band 100Hz-5KHz: <1mV rms psophometric
Wide band 5kHz-1MHz: <5mV rms unweighted
Peak to Peak 0-20MHz: <50mV peak to peak
Isolation:
Input to Output: 4000V DC
Input to Chassis: 3500V DC (VDR to chassis removed)
Output to Chassis: 2100V DC
Environmental Requirements
Ambient Temperature:
Nominal: 25+/-5ºC
Range: -10ºC to +70ºC (maximum output power is derated above +50ºC)
Storage Temperature: -20ºC to +70ºC
Humidity: 5-95% RH (non-condensing)
Altitude: <2500m, De-rate maximum ambient temperature
by 4ºC per 1000m above sea level.
Mechanical
Dimensions, W, H, D: 111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)
Weight: 1.4kg
Shipping Dimensions W, H, D: 120mm, 52mm, 325mm
Shipping Weight: 1.5kg
Cooling: Forced cooled.
Compliances
Safety: EN60950
Electrostatic Discharge: CISPR24
Radiated Radio Frequency: CISPR22
AC Harmonics: EN61000-3-2
AC Flicker and Fluctuation: EN61000-3-3
Other: CE & RoHS compliant.
48
AC Input
Nominal: 230V
Voltage Range: 90-300V (reduced power below 175V)
Frequency Range: 45-65 Hz
V Power Factor: >0.99
nominal output voltage. Efficiency: >90% (>50% output power)
Input Fuses: HRC fuses in phase and neutral.
1.0
Protection:
Input Voltage: Auto shutdown, auto restart when correct voltage restored.
Input Inrush: <2x maximum input current.
Maximum Input Current: 7A
kW DC Output
nominal output power. Output Ratings: Constant power output from 48V to 58V
Nominal Voltage: 48V
Rated Voltage: 58V
21.0
Voltage Range: 43-60V
Maximum Current: 21A
Regulation:
Line: ±0.1%
Environmental Requirements
Ambient Temperature:
Nominal: 25+/-5ºC
Range: -10ºC to +75ºC (maximum output power is derated above +50ºC)
Storage Temperature: -20ºC to +75ºC
Humidity: 5-95% RH (non-condensing)
Altitude: <2500m, De-rate maximum ambient temperature
by 4ºC per 1000m above sea level.
Mechanical
Dimensions, W, H, D: 111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)
Weight: 1.4kg
Shipping Dimensions W, H, D: 120mm, 52mm, 325mm
Shipping Weight: 1.5kg
Cooling: Forced cooled
Compliances
Safety: EN60950
Electrostatic Discharge: CISPR24
Radiated Radio Frequency: CISPR22
AC Harmonics: EN61000-3-2
AC Flicker and Fluctuation: EN61000-3-3
Other: CE & RoHS compliant.
48
AC Input
Nominal: 230V
Voltage Range: 90-300V (reduced power below 175V)
Frequency Range: 45-65 Hz
Power Factor: >0.99 V
Efficiency: >92% (>50% output power) nominal output voltage.
Input Fuses: HRC fuses in phase and neutral.
800
Maximum Input Current: 5.5A
Protection:
Input Voltage: Auto shutdown, auto restart when correct voltage restored.
Input Inrush: <2x maximum input current.
DC Output W
Output Ratings: Constant power output from 54V to 58V nominal output power.
Nominal Voltage: 48V
Rated Voltage: 58V
16.6
Voltage Range: 43-60V
Maximum Current: 16.6A
Regulation:
Line: ±0.1%
Load: ±0.5% (no load to full load)
A
Hold-up Time: >15ms for 20% output voltage drop.
maximum output current.
Start-up Time: Start up delay 1 second. (varies with AC supply voltage)
Walk-in delay 6 seconds at full output. (varies with DC output voltage)
Protection:
Current Limit: Adjustable to 50-100% of maximum rated current.
Over Temperature: Automatic current turndown, backup shutdown protection.
Polarity Reversal: Output fuse with crowbar diode.
Over voltage: Adjustable limit.
Noise: (under nominal conditions)
Ripple <100Hz: <1mV rms unweighted
Voice band 100Hz-5KHz: <2mV rms psophometric
Wide band 5kHz-1MHz: <5mV rms unweighted
Peak to Peak 0-20MHz: <50mV peak to peak
Isolation:
Input to Output: 4000V DC
Input to Chassis: 3500V DC (VDR to chassis removed)
Output to Chassis: 2100V DC
Environmental Requirements
Ambient Temperature:
Nominal: 25+/-5ºC
Range: -20ºC to +70ºC (maximum output power is derated above +50ºC)
Storage Temperature: -20ºC to +70ºC
Humidity: 0-98% RH (non-condensing)
Altitude: <3000m, De-rate maximum ambient temperature
by 4ºC per 1000m above sea level.
Mechanical
Dimensions, W, H, D: 55mm , 44mm (1U), 235mm overall (rack depth 260mm)
Weight: 800g
Shipping Dimensions W, H, D: 100mm, 80mm, 300mm
Shipping Weight: 1.0kg
Cooling: Forced cooled.
Compliances
Safety: EN60950
Electrostatic Discharge: CISPR24
Radiated Radio Frequency: CISPR22
AC Harmonics: EN61000-3-2
AC Flicker and Fluctuation: EN61000-3-3
Other: CE & RoHS compliant.
- Forced cooled. Flat mount rectifiers have been developed to allow provision of simple, and low
- Thermally protected. cost solutions where only a limited amount of rack space is available. With all
- Power factor corrected. input and output connections available on the front panel of the rectifier units
- Input/output voltage they can be easily integrated in simple DC systems solutions.
and current protected.
- Temperature compensation.
With power ratings of 300W up to 1.4kW and output voltages of 12, 24 and
- Automatic float/boost charge cycle.
48V DC these rectifiers offer temperature compensation, and auto float/boost
- Alarm and control interface
switching as standard.
including active load sharing.
- Optional built-in low
They have options available for internal low voltage disconnect (LVD) and an
voltage disconnect.
- Optional internal alarm alarm card, with relay outputs. These rectifiers can provide the powering solution
card with relay outputs. for most small and medium telecommunications, and data networking power
applications.
Efficient and reliable, these rack mounting rectifiers allow for easy paralleling of
modules to provide redundancy or higher power outputs. Internal options include
low voltage disconnect (LVD) and an alarm card with relay outputs.
The unique design allows for mounting two rectifiers in a 1U x 19” rack space.
Custom configurations can be specified and additional features can be added.
Easy to install and compact, these robust, reliable rectifiers are forced
cooled by a speed controlled and monitored fan.
AC Input
RF1448 RF1124 RF748U RF624U RF512U RF348U
Nominal: 220/240V, 50/60Hz 220/240V, 50/60Hz 110-220V, 50/60Hz 110-220V, 50/60Hz 110-220V, 50/60Hz 110-220V, 50/60Hz
Voltage Range: 180-275V AC 180-275V AC 100-275V AC 100-275V AC 100-275V AC 100-275V AC
(full power output), (full power output), (full power output), (full power output), (full power output), (full power output),
150-180V AC 150-180V AC 85-100V AC 85-100V AC 85-100V AC 85-100V AC
(reduced power output) (reduced power output) (reduced power output) (reduced power output) (reduced power output) (reduced power output)
Frequency Range: 45-66Hz
Power Factor: >0.93 (full load)
RF1448 RF1124 RF748U RF624U RF512U RF348U
Efficiency: 92% 90% 89% 87% 85% 85%
Maximum Input Current: 8.5A 8.5A 8.5A 8.5A 8.5A 8.5A
Input Fuses: HRC fuses in phase & neutral.
Protection:
Input Voltage: Automatic shutdown, restarts automatically when correct voltage restored.
Input Rush: <2x maximum input current.
Environmental Requirements
Nominal Ambient Temperature: 25+/-5°C
Range: -10 to +50°C
Humidity: 5-95% RH (non-condensing.)
Altitude: <2500m de-rate maximum ambient temperature by +4˚ per 1000m above sea level.
Mechanical
Dimensions, W, H, D: 227mm, 44mm (1U), 270mm, (293mm over handle)
Weight: 1.5kg
Shipping Dimensions, W, H, D: 377mm, 235mm, 122mm
Shipping Weight: 2.4kg
Cooling: Forced cooled.
Connections:
Mains: IEC 320 universal connection.
Output to Load: 4 way lumberg macromodule.
Temperature Sensor: 2 way lumberg macromodule.
Monitor Connection: RJ45
Internal Alarm Card: Mini combicon.
Standard Features
Temperature Compensation: Output voltage slope adjustable 0.1 to 0.2%/°C (standard)
Auto Float/Boost: Rectifier enters boost mode at power up. When battery current reduces to float threshold limit (adjustable from 0.1A to 40% MRC), unit reverts to float voltage setting.
When in boost but out of current limit, rectifier will automatically switch back to float after approximately four hours.
If battery current exceeds the float threshold limit when the rectifier is in float mode it will automatically switch to boost mode.
Alarm and Indicator Controls: Positive V out, Load share signal (in/out), External shutdown, Open collector ‘off normal’ alarm, (OSVD, over temp., current limit, fan fail), LVD synchronisation signal (in/out),
Temperature compensation input signal, Open collector rectifier fail (via 4k7 resistor), Open collector mains fail, Negative V out.
Options
Low Voltage Disconnect: RF1448 RF1124 RF748U RF624U RF512U RF348U
Voltage Adjustment Range: 38-48V 19-24V 38-48V 19-24V 9.5-12V 38-48V
Maximum Load Current: 25A 40A 12A 22A 40A 6A
Internal Alarm Card: 4x N.O or N.C (selectable) relay contacts with single common for rectifier fail, off normal, float low, float high. 1x VF changeover relay contact for mains fail.
Relay contacts rated at 100V DC 1A. Connections via “mini combicon” connector accepts 1.5mm dia wire.
Maintenance
LED Indicators: Green - Mains on. (primary converter operating)
Green - Temperature probe connected and within normal limits.
Red - Rectifier ‘failed’.
Green - Rectifier in ‘float’ mode.
Yellow - Rectifier in ‘boost’ mode.
Yellow - Rectifier in ‘current’ limit.
Red - Rectifier ‘off normal’. (over temp., OVSD, low output volts)
Internal Adjustments: Float voltage.
Boost voltage.
Over voltage shut down.
Current limit.
Temperature compensation slope.
Auto boost to float threshold limit.
Load disconnect voltage. (if fitted)
Load disconnect hysteresis voltage. (if fitted)
Compliances
Safety: EN60950
Electrostatic Discharge: CISPR24
Radiated Radio Frequency: CISPR22
AC Harmonics: EN61000-3-2
AC Flicker and Fluctuation: EN61000-3-3
Ordering Information
RFxxxx-10: Standard with temperature compensation, auto float boost, alarm and control I/F.
RFxxxx-11: Standard with temperature compensation, auto float boost, alarm and control I/F, low volts disconnect.
RFxxxx-20: Standard with temperature compensation, auto float boost, alarm and control I/F, alarm card.
RFxxxx-21: Standard with temperature compensation, auto float boost, alarm and control I/F, low volts disconnect, alarm card.
- Convection cooled. The Enatel RW series of wall mount rectifiers have been developed to provide
- Thermally protected. fully integrated power solutions for small telecommunications, and data
- Power factor corrected. networking applications.
- Input/output voltage
and current protected. Easily paralleled to provide redundancy, or higher power outputs these rectifiers
- Automatic float/boost
are simple to install and can be bolted directly to a wall or flat panel space.
charge cycle.
Providing outputs of 12, 24 and 48V from 300W up to 700W output these
- Alarm and control interface
rectifiers offer temperature compensation, and auto float/boost switching
with active load sharing.
as standard.
- Temperature compensation.
- Output current indicator.
- Optional built-in low They have options available for internal low voltage disconnect (LVD) and an
voltage disconnect. alarm card, with relay outputs. These highly efficient rectifiers offer a range of
- Optional internal alarm output voltages and power levels.
card with relay outputs.
Easy to install and compact, these robust, reliable rectifiers are convection
cooled and are available with temperature compensation, and options for internal
low voltage disconnect (LVD) and alarm card with relay outputs.
AC Input
Nominal: 110/220V, 50/60Hz
Voltage Range: 100-275V AC (full power output), 85-100V AC (reduced power output)
Frequency Range: 45-66Hz
Power Factor: >0.99 (full load)
RW748U RW624U RW512U RW348U RW324U RW312U
Efficiency: 88% 87% 85% 88% 87% 85%
Maximum Input Current: 8.5A 8.5A 8.5A 8.5A 4A 4A
Input Fuses: HRC fuses in phase & neutral.
Protection:
Input Voltage: Automatic shutdown, restarts automatically when correct voltage restored.
Input Rush: <2x maximum input current.
Environmental Requirements
Nominal Ambient Temperature: 25+/-5°C
Range: -10 to +50°C
Humidity: 5-95% RH (non-condensing)
Altitude: <2500m de-rate maximum ambient temperature by +4˚ per 1000m above sea level.
Mechanical
Dimensions, W, H, D: 311mm, 163mm, 62mm
Weight: 1.5kg
Shipping Dimensions, W, H, D: 377mm, 235mm, 122mm
Shipping Weight: 2.4kg
Cooling: Convection cooled.
Connections:
Mains: IEC 320 universal connection.
Output to Load: 4 way lumberg macromodule.
Output to Batteries: 4 way lumberg macromodule.
Temperature Sensor: 2 way lumberg macromodule.
Monitor Connection: RJ45.
Internal Alarm Card: Mini combicon.
Standard Features
Output Current Indicator: Ten segment red LED “dot” display (standard)
Temperature Compensation: Output voltage slope adjustable 0.1 to 0.2%/°C (standard)
Auto Float/Boost: Rectifier enters boost mode at power up. When battery current reduces to float threshold limit (adjustable from 0.1A to 40% MRC), unit reverts to float voltage setting.
When in boost but out of current limit, rectifier will automatically switch back to float after approximately four hours.
If battery current exceeds the float threshold limit when the rectifier is in float mode it will automatically switch to boost mode.
Alarm and Indicator Controls: Positive V out, Load share signal (in/out), External shutdown, Open collector ‘off normal’ alarm (OSVD, over temp. limit), LVD synchronisation signal (in/out)
Temperature compensation input signal, Open collector rectifier fail (via 4k7 resistor), Open collector mains fail, Negative V out.
Options
Low Voltage Disconnect: RW748U RW624U RW512U RW348U RW324U RW312U
Voltage Adjustment Range: 38-48V 19-24V 9.5-12V 38-48V 19-24V 9.5-12V
Maximum Load Current: 12A 22A 35A 6A 10A 20A
Internal Alarm Card: 4x N.O or N.C (selectable) relay contacts with single common for rectifier fail, off normal, float low, float high. 1x VF changeover relay contact for mains fail.
Relay contacts rated at 100V DC 1A. Connections via “mini combicon” connector accepts 1.5mm dia wire.
Maintenance
LED Indicators: Green - Mains on. (primary converter operating)
Green - Temperature probe connected and within normal limits.
Red - Rectifier ‘failed’.
Green - Rectifier in ‘float’ mode.
Yellow - Rectifier in ‘boost’ mode.
Yellow - Rectifier in ‘current’ limit.
Red - Rectifier ‘off normal’. (over temp. OVSD, low output volts)
Internal Adjustments: Float voltage.
Boost voltage.
Over voltage shut down.
Current limit.
Temperature compensation slope.
Auto boost to float threshold limit.
Load disconnect voltage. (if fitted)
Load disconnect hysteresis voltage. (if fitted)
Compliances
Safety: EN60950
Electrostatic Discharge: CISPR24
Radiated Radio Frequency: CISPR22
AC Harmonics: EN61000-3-2
AC Flicker and Fluctuation: EN61000-3-3
Ordering Information
RWxxxx-10: Standard with temperature compensation, auto float boost, alarm and control I/F.
RWxxxx-11: Standard with temperature compensation, auto float boost, alarm and control I/F, low volts disconnect.
RWxxxx-20: Standard with temperature compensation, auto float boost, alarm and control I/F, alarm card.
RWxxxx-21: Standard with temperature compensation, auto float boost, alarm and control I/F, low volts disconnect, alarm card.
- Integrated monitoring presents Enatel’s ISM series inverter solutions offer a hot swappable modular inverter
simplified systems management. system for supplying critical AC loads in telecom, and data networking
- Hot-swap/hot-plug modules applications.
with n+1 redundancy.
- Small size means more room for One of the unique features offered by the Enatel system solution is the ability to
revenue generating equipment.
integrate AC/DC rectifiers, DC/DC converters and also DC/AC inverters into a
- Fully featured telecom
system with a single controller, providing remote monitoring capabilities from a
grade inverters.
single point.
- TCP/IP and SNMP network
monitoring optional.
The inverter modules are available in 1.5kVA with either 110/120 or 220/230V AC
- High reliability means
less cost of maintenance. output, and are scalable up to 15kVA. The inverter system solutions also include
- Full remote monitoring reduces 12kVA static switch and maintenance bypass modules.
maintenance costs.
- Easily customized and configured to For further information on Enatel’s range of inverter systems, contact us today.
suit eachcustomers individual needs.
Supervisory Module
SM32
M 23
M 23 M 23
M 23 M 23
M 23 M 23
M 23 M 23
Efficient and reliable, these modular rack mount inverters allow for easy - Pure sine wave.
paralleling of modules to provide redundancy or higher power outputs. - Hot swapable.
Designed for use in modern telecommunications networks these inverters - High efficiency.
offer unrivalled power densities. - Smart fan speed control.
- Wide operation temperature range.
- DSP chip designed.
The unique design allows for mounting nine inverters in a 5U x 19” rack space
- N+X redundancy system.
or two inverters in a 1U x 19” rack space.
- Lower audible noise.
- High power density.
“Plug and Play” installation allows quick and easy installation and system
- Enatel RCP bus.
expansion. These robust, reliable inverters are forced cooled by two speed
- 48V DC telecom system application.
controlled and monitored high reliability fans. - CE & RoHS compliant.
DC Input
Operating Voltage Range: 40.5-58V DC
AC Output
Nominal Output Voltage: 110/230V AC (refer to part number table below for model numbers)
Output Voltage Range: 110/115/120V AC or 208/220/230/240V AC
Output Voltage Tolerance: +/- 2%
Output Voltage Frequency: 50/60Hz selectable.
Output Frequency Tolerance: +/- 0.5%
Total Harmonic Distortion: <3% on linear loads.
<5% for non linear loads.
Turn On Delay: <3 seconds.
Crest Factor: 3:1 (nominal power)
Efficiency: 90%
Output Power (refer to part number table below for model numbers)
Nominal Value: 1000VA, 800W/
1500VA, 1200W
Overload (5 Seconds): 2000VA
Permanent Overload: 10%
Admissible Load Power Factor: 0 inductive to 0 capacitive (100% load)
Isolation:
Input/Output: 2500V AC
Output/Earth: 2500V AC
Input Earth: 1500V AC
Operating Temperature Range: -40ºC to +50ºC, derated to +70ºC
Acoustic Noise: <55dBa @ 1m
Display: 3x LEDs, fail, off normal, power on.
Serial Comms: Enatel SBI interface to SM3X supervisory module.
Mechanical
Dimensions, W, H, D: 215mm, 43.8mm, 270mm overall.
Weight: 2.5kg
Shipping Dimensions W, H, D: 52mm, 230mm, 340mm
Shipping Weight: 2.65kg
Cooling: Forced cooled.
Compliances
Immunity: CISPR24
Emissions: CISPR22 Class B
Safety: IEC60950
Other: CE & RoHS compliant.
Part Numbers
The Enatel SBM series static bypass module increases system reliability by - Universal input range.
automatically switching between the inverter output and the utility supply. - Hot-swap replacement in shelf.
- Back feed protection.
The SBM12000 can be programmed so that the system operates in a standby - Redundant fan design.
backup mode were the utility is the normal source of supply or alternatively the - Redundant power supply design.
- Fast transfer time, typically
system can be the normal source of supply with automatic switchover to the
less than ¼ cycle.
utility in the event of system failure.
- Wide operation temperature
range -20 to +70°C.
- Lower audible noise <55dBA.
Input
- Emergency power off
AC Voltage Range:
function embedded.
110/115/120V AC: From 89 to 138V AC. - No-cross connect.
208/220/240V AC: 176 to 276V AC. - Optional maintenance bypass
Over Voltage Threshold: switch function with interlock.
Adjustable Using Controller: - Operation priority setup of
220 to 240V AC for 208V AC systems. transfer side by setting in
233 to 252V AC for 220V AC systems. controller module.
244 to 264V AC for 230V AC systems.
Output
Waveform: Sinusoidal.
Part Number:
- Force cooled. These converters offer plug and play operation, and can be easily paralleled to
- Thermally protected. provide higher power outputs.
- Input/output voltage
and current protected. These units offer the same high levels of conversion efficiency as other Enatel
- Wide input voltage range. power products, and will provide the same benefits to the customer of reduced
- Serial alarm and control interface.
operating costs and lower levels of heat dissipation.
- Microprocessor controlled.
The converters include a relay contact to indicate converter failure, and have a
load share input that ensures that all units connected in parallel carry an equal
share of the load.
Environmental Requirements
Ambient Temperature:
Nominal: +25 +/- 5ºC
Range: -10 to +70ºC (maximum output power is derated above +50ºC)
Storage Temperature: -20 to +70ºC
Humidity: 5-95% RH (non condensing)
Altitude: <2500m, De-rate maximum ambient temperature
by +4ºC per 1000m above sea level.
Mechanical
Dimensions W, H, D: 111.5mm, 44mm (1U), 282 overall (rack depth 260mm)
Weight: 1.1kg
Shipping Dimensions W, H, D: 170mm, 52mm, 325mm
Shipping Weight: 1.6kg
Cooling: Forced cooled.
Compliances
Safety: EN60950
Electostatic Discharge: CISPR24
Radiated Radio Frequency: CISPR22
Additional Accesories
ACM-4T: 1U 4 position DC-DC converter shelf, no cables.
Part Numbers
CM1760-48: 1.7kW 48 to 60V DC modular DC-DC converter.
CM1748-60: 1.7kW 60 to 48V DC modular DC-DC converter.
CM1748-48: 1.7kW 48 to 48V DC modular DC-DC converter.
Environmental Requirements
Ambient Temperature:
Nominal: +25 +/- 5ºC
Range: -10 to +70ºC (maximum output power is derated above +50ºC)
Storage Temperature: -20 to +70ºC
Humidity: 5-95% RH (non condensing)
Altitude: <2500m, De-rate maximum ambient temperature
by +4ºC per 1000m above sea level.
Mechanical
Dimensions W, H, D: 111.5mm, 44mm (1U), 282 overall (rack depth 260mm)
Weight: 1.1kg
Shipping Dimensions W, H, D: 170mm, 52mm, 325mm
Shipping Weight: 1.6kg
Cooling: Forced cooled.
Compliances
Safety: EN60950
Electostatic Discharge: CISPR24
Radiated Radio Frequency: CISPR22
Other: CE & RoHS compliant
Additional Accesories
ACM-4T: 1U 4 position DC-DC converter shelf, no cables.
Part Numbers
CM1048-24: 1.0kW 24 to 48V DC modular DC-DC converter.
CM1024-48: 1.0kW 48 to 24V DC modular DC-DC converter.
CM648-24: 650W 24 to 48V DC modular DC-DC converter.
CM624-48: 650W 48 to 24V DC modular DC-DC converter.
CM612-48: 560W 48 to 12V DC modular DC-DC converter.
Enatel offer a range of supervisory modules and monitoring options, which have - Temperature compensation.
been designed to work with our power products. Allowing for easy integration - LVD control.
into our complete DC power systems solutions for telecommunications and data - Setup from front panel.
networking applications. - Boost control and timer.
- LCD display of parameters.
LVD
Input
Voltage: 16-75V DC
Current: <150mA maximum.
Interface
Display: 4 line x 16 character multi-lingual alpha numeric display.
dual lvd control. Communications:
Serial: 1x USB port on front panel for local PC interface.
1x RS232 port, rear mounted for remote serial/modem communications.
WEB
Relay: 6x alarm and control relays, five of which can be mapped for customized
alarm settings. (extra available with I/O expansion board)
TCP/IP: Ethernet interface for communication using SNMP protocol and internal
web based configurator.
LVD: 3x standard or 2x pulse control LVD contacts.
(for magnetically latched LVD contactors)
Indicators:
web based configurator. 3x LED’s: Green - power on/monitor OK.
Yellow - non urgent alarm.
USB
Red - urgent alarm.
Audible: 90dBA buzzer mappable to user defined conditions.
Controls: 3x push buttons for parameter setting or viewing on front panel.
Signal Inputs: 2x serial buses for rectifier control and interface to peripheral modules.
10x general purpose inputs.
(6x for customer connection, 4x reserved for internal system connection.)
4x battery MCB sensors. (reserved for internal system connection.)
3x current shunt inputs. (reserved for internal system connection.)
usb port for local connection. 1x DC voltage inputs. (reserved for internal system connection.)
Alarms: 6x alarm relays.
Alarm Contacts: 0.3A 100V volts free changeover contacts.
Default Alarm Map:
Relay 1: Monitor fail. (non programmable.)
Relay 2: Non-urgent. (programmable.)
Relay 3: Urgent. (programmable.)
Relay 4 - 6: Unassigned.
Logging Capacity:
Periodic Log: Typically 16000 records. (dependant on number of parameters logged.)
Event Log: Typically 16000 records. (dependant on number of parameters logged.)
Battery Mid-point Monitoring: 3x strings with individual string currents.
(more available with shared string currents.)
Physical
Dimensions, W, H, D: 111.5mm , 44mm (1U), 265mm overall (rack depth 244mm)
Weight: 365g
Connections: Relay outputs, mini combicon to accept 1.5mm csa wire.
Serial communications to rectifier shelf & peripheral devices - RJ45.
USB port - USB mini B.
Operating Temperature: -25 to +55°C
Storage Temperature: -50 to +85°C
Compliances
Radiated Emissions: EN55022
RF Susceptibility: EN55024
Optional Accessories
ACA-TC3C: 3m temperature sensor and cable.
ACA-TC7C: 7m temperature sensor and cable.
ASM-AC3P: 3 phase AC voltage and current monitor.
ASM-ABM-24: Battery condition monitor, 24 blocks. (maximum 4x BCM cards)
ASM-SM36IO: Standard I/O expansion board (maximum of 4 per supervisory module.)
Voltage Range: 15-75V DC
Current: <150mA maximum
Connection: Connects via rectifier serial bus, 2x RJ45.
Alarms: Up to 8x alarm and control relays, able to
be mapped for customized alarm settings.
Signal Inputs: Up to 6x digital inputs. Up to 6x analogue inputs.
Operating Temperature: -25 to +55°C
Storage Temperature: -50 to +85°C
Part Numbers
SM36-00: Standard 1U modular controller, 6x relays, 6x digital inputs.
SM36-00-1U: Standard 1U x 19” mounting version controller, 6x relays, 6x digital inputs.
SM36-10-1U: Standard 1U x 19” mounting version controller, 6x relays,
6x digital inputs; with standard I/O expansion board.
SM36-00-PM: Standard panel mount version controller, 6x relays, 6x digital inputs.
SM36-10-PM: Standard panel mount version controller, 6x relays,
6x digital inputs; with standard I/O expansion board.
126
Input
Voltage: 16-75V DC
Current: <150mA maximum.
Interface
Display: 4 line x 16 character multi-lingual alpha numeric display.
Communications: serial control for up to 126 rectifiers/
Serial: 1x USB port on front panel for local PC interface. converters plus peripheral devices.
Relay: 6x alarm and control relays, five of which can
LCD
be mapped for customized alarm settings.
LVD: 3x standard or 2x pulse control LVD contacts.
(for magnetically latched LVD contactors)
Indicators:
3x LED’s Green - power on/monitor OK.
Yellow - non urgent alarm.
Red - urgent alarm.
Audible: 90dBA buzzer mappable to user defined conditions. lcd display.
Controls: 3x push buttons for parameter setting or viewing on front panel.
USB
Signal Inputs: 2x serial buses for rectifier control and interface to peripheral modules.
10x general purpose inputs.
(6x for customer connection, 4x reserved for internal system connection.)
4x battery MCB sensors. (reserved for internal system connection.)
3x current shunt inputs. (reserved for internal system connection.)
1x DC voltage inputs. (reserved for internal system connection.)
Alarms: 6x alarm relays.
Alarm Contacts: 0.3A 100V volts free changeover contacts.
Default Alarm Map: usb port for local connection.
Relay 1: Monitor fail. (non programmable.)
Relay 2: Non-urgent. (programmable.)
Relay 3: Urgent. (programmable.)
Relay 4 - 6: Unassigned.
Logging Capacity:
Periodic Log: Typically 16000 records. (dependant on number of parameters logged.)
Event Log: Typically 16000 records. (dependant on number of parameters logged.)
Battery Mid-point Monitoring: 3x strings with individual string currents.
(more available with shared string currents.)
Physical
Dimensions, W, H, D: 111.5mm , 44mm (1U), 265mm overall (rack depth 244mm)
Weight: 325g
Connections: Relay outputs, mini combicon to accept 1.5mm csa wire.
Serial communications to rectifier shelf & peripheral devices - RJ45.
USB port - USB mini B.
Operating Temperature: -25 to +55°C
Storage Temperature: -50 to +85°C
Compliances
Radiated Emissions: EN55022
RF Susceptibility: EN55024
Optional Accessories
ACA-TC3C: 3m temperature sensor and cable.
ACA-TC7C: 7m temperature sensor and cable.
ASM-AC3P: 3 phase AC voltage and current monitor.
ASM-ABM-24: Battery condition monitor, 24 blocks. (maximum 4x BCM cards.)
ASM-SM3XIO: Standard I/O expansion board (maximum of 4 per supervisory module.)
Voltage Range: 15-75V DC
Current: <150mA maximum
Connection: Connects via rectifier serial bus, 2x RJ45.
Alarms: Up to 8x alarm and control relays, able to
be mapped for customized alarm settings.
Signal Inputs: Up to 6x digital inputs. Up to 6x analogue inputs.
Operating Temperature: -25 to +55°C
Storage Temperature: -50 to +85°C
Part Numbers
SM35-00: Standard 1U modular controller, 6x relays, 6x digital inputs.
SM35-00-1U: Standard 1U x 19” mounting version controller, 6x relays, 6x digital inputs.
SM35-10-1U: Standard 1U x 19” mounting version controller, 6x relays,
6x digital inputs; with standard I/O expansion board.
SM35-00-PM: Standard panel mount version controller, 6x relays, 6x digital inputs.
SM35-10-PM: Standard panel mount version controller, 6x relays,
6x digital inputs; with standard I/O expansion board.
LVD
Input
Voltage: 16-75V DC
Current: <150mA maximum.
Interface
Display: 4 line x 16 character multi-lingual alpha numeric display.
dual lvd control. Communications:
Serial: 1x USB port on front panel for local PC interface.
1x RS232 port, rear mounted for remote serial/modem communications.
WEB
Relay: 3x alarm and control relays, two of which
can be mapped for customized alarm settings.
(extra available with I/O expansion board)
TCP/IP: Ethernet interface for communication using SNMP
protocol and internal web based configurator.
LVD: 3x standard or 2x pulse control LVD contacts.
(for magnetically latched LVD contactors)
web based configurator. Indicators:
3x LED’s Green - power on/monitor OK.
Yellow - non urgent alarm.
USB
Red - urgent alarm.
Audible: 90dBA buzzer mappable to user defined conditions.
Controls: 3x push buttons for parameter setting or viewing on front panel.
Signal Inputs: Serial bus for rectifier control and interface to peripheral modules.
Fuse fail.
5x spare digital inputs.
2x temperature sensors.
usb port for local connection. 3x current shunts.
2x DC voltage inputs.
Alarms: 3x alarm relays.
Alarm Contacts: 0.3A 100V volts free changeover contacts.
Default Alarm Map: Urgent.
Non-urgent.
Monitor fail.
Logging Capacity:
Periodic Log: 16384 records. (dependant on number of parameters logged.)
Event Log: 16384 records. (dependant on number of parameters logged.)
Physical
Dimensions, W, H, D: 111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)
Weight: 1.5kg
Connections: Relay outputs, mini combicon to accept 1.5mm csa wire.
Serial communications to rectifier shelf & peripheral devices - RJ45.
USB port - USB mini B.
Operating Temperature: -25 to +55°C
Storage Temperature: -50 to +85°C
Compliances
Radiated Emissions: EN55022
RF Susceptibility: EN55024
Optional Accessories
ACA-TC3C: 3m temperature sensor and cable.
ACA-TC7C: 7m temperature sensor and cable.
ASM-AC3P: 3 phase AC voltage and current monitor.
ASM-ABM-24: Battery condition monitor, 24 blocks. (maximum 4x BCM cards.)
ASM-SM3XIO: Standard I/O expansion board (maximum of 4 per supervisory module.)
Voltage Range: 15-75V DC
Current: <150mA maximum
Connection: Connects via rectifier serial bus, 2x RJ45.
Alarms: Up to 8x alarm and control relays, able to
be mapped for customized alarm settings.
Signal Inputs: Up to 6x digital inputs. Up to 6x analogue inputs.
Operating Temperature: -25 to +55°C
Storage Temperature: -50 to +85°C
Part Numbers
SM32-00: Standard 1U modular controller, 3x relays, 6x digital inputs.
SM32-10: Standard 1U modular controller, 3x relays, 6x digital inputs;
with standard I/O expansion board mounted onto baseplate metalwork.
SM32-00-1U: Standard 1U x 19” mounting version controller,
3x relays, 6x digital inputs.
SM32-10-1U: Standard 1U x 19” mounting version controller, 3x relays,
6x digital inputs; with standard I/O expansion board.
SM32-00-PM: Standard panel mount version controller, 3x relays, 6x digital inputs.
SM32-10-PM: Standard panel mount version controller, 3x relays,
6x digital inputs; with standard I/O expansion board.
126
Input
Voltage: 16-75V DC
Current: <150mA maximum.
Interface
Display: 4 line x 16 character multi-lingual alpha numeric display.
Communications: serial control for up to 126 rectifiers/
Serial: 1x USB port on front panel for local PC interface. converters plus peripheral devices.
Relay: 3x alarm and control relays, two of which
LCD
can be mapped for customized alarm settings.
LVD: 3x standard or 2x pulse control LVD contacts.
(for magnetically latched LVD contactors)
Indicators:
3x LED’s Green - power on/monitor OK.
Yellow - non urgent alarm.
Red - urgent alarm.
Audible: 90dBA buzzer mappable to user defined conditions. lcd display.
Controls: 3x push buttons for parameter setting or viewing on front panel.
USB
Signal Inputs: 2x serial buses for rectifier control and interface to peripheral modules.
Fuse fail.
5x spare digital inputs.
2x temperature sensors.
3x current shunts.
2x DC voltage inputs.
Alarms: 3x alarm relays.
Alarm Contacts: 0.3A 100V volts free changeover contacts. usb port for local connection.
Default Alarm Map: Urgent.
Non-urgent.
Monitor fail.
Logging Capacity:
Periodic Log: 16384 records. (dependant on number of parameters logged.)
Event Log: 16384 records. (dependant on number of parameters logged.)
Physical
Dimensions, W, H, D: 111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)
Weight: 1.5kg
Connections: Relay outputs, mini combicon to accept 1.5mm csa wire.
Serial communications to rectifier shelf & peripheral devices - RJ45.
USB port - USB mini B.
Operating Temperature: -25 to +55°C
Storage Temperature: -50 to +85°C
Compliances
Radiated Emissions: EN55022
RF Susceptibility: EN55024
Optional Accessories
ACA-TC3C: 3m temperature sensor and cable.
ACA-TC7C: 7m temperature sensor and cable.
ASM-AC3P: 3 phase AC voltage and current monitor.
ASM-ABM-24: Battery condition monitor, 24 blocks. (maximum 4x BCM cards.)
ASM-SM3XIO: Standard I/O expansion board (maximum of 4 per supervisory module.)
Voltage Range: 15-75V DC
Current: <150mA maximum
Connection: Connects via rectifier serial bus, 2x RJ45.
Alarms: Up to 8x alarm and control relays, able to
be mapped for customized alarm settings.
Signal Inputs: Up to 6x digital inputs. Up to 6x analogue inputs.
Operating Temperature: -25 to +55°C
Storage Temperature: -50 to +85°C
Part Numbers
SM31-00: Standard 1U modular controller, 3x relays, 6x digital inputs.
SM31-10: Standard 1U modular controller, 3x relays, 6x digital inputs;
with standard I/O expansion board mounted onto baseplate metalwork.
SM31-00-1U: Standard 1U x 19” mounting version controller,
3x relays, 6x digital inputs.
SM31-10-1U: Standard 1U x 19” mounting version controller, 3x relays,
6x digital inputs; with standard I/O expansion board.
SM31-00-PM: Standard panel mount version controller, 3x relays, 6x digital inputs.
SM31-10-PM: Standard panel mount version controller, 3x relays,
6x digital inputs; with standard I/O expansion board.
TEMP
Input
Voltage:
35-60V DC
Current:
<85mA maximum.
Interface
temperature compensation. Display: 6 character starburst.
Communications: Interfaces with up to 6x RF series rectifiers.
Serial: RS232 serial for downloading configuration files.
LVD
Relay: 7x alarm and control relays.
Indicators: 8x LED.
Controls: 3x push buttons for parameter setting on front panel.
Signal Inputs: External shutdown. Fuse fail. Rectifier fail. Mains fail.
Rectifier off normal. 2x voltmeter. 2x current meter. (100mV)
Alarms: 7x alarm relays.
Alarm Contacts: 1A 100V volts free changeover contacts.
Alarm List: Off normal. Rectifier fail. Mains fail. Float high. Float low.
lvd control. LVD. (control line for external LVD contactor)
Physical
LCD
Dimensions W, H, D: 275mm, 44mm (1U), 104mm
Weight: 0.55kg
Connections: Mini combicon to accept 1.5mm csa wire.
Operating Temperature: -25 to +55°C
Storage Temperature: -50 to +85°C
Versions
SM11-12: 12V
lcd display of parameters. SM11-24: 24V
SM11-48: 48V
Accessories
Temp Sensor:
ACA-TC2U: 2 metre temp sensor and cable.
ACA-TC7U: 7 metre temp sensor and cable.
Rectifier Interface:
ACA-Alarm0.5: 500mm RJ45 patch cable.
Current Sensor:
ACS-S150: 150 Amp 100mV shunt assembly.
- Uses the SM3X temp sensor The optional fan controller module allows the smart control of four 24V or 48V
to control fan speed. fans with fan stall detection.
- Individual minimum fan speed
configurable to prevent fan stall. Up to two fan controller modules can be connected in a system, giving a total of
- 4x fans controlled per module 8 controlled fans. Each module operates individually and has separate settings,
and up to 2x modules per system.
so can have different temperature set points and operate at different speeds.
The fans on one module all operate at the same speed.
Number Of Fans Controlled: 4x per fan controller module. (8x per system)
Number Of Modules On Bus: 2x per system.
Temperature Control Range: The range of the SM3X temp sensor.
Communications: Enatel serial bus interface.
Alarms: Controlled via SM3X fan fail.
Part Number:
Fan Controller Board: ASM-FCM4
The Enatel BCM consists of peripheral circuit boards that can be added to an - Compatible with SM22, SM32
Enatel system utilizing the SM22, SM32 or SM36 supervisory module to monitor or SM36 supervisory modules.
the performance of the installed stand-by battery system. - 26 voltage inputs.
- 8 pairs of current inputs.
The monitor is designed to be connected to a number of different battery - 4 temperature inputs.
- Discharge logging.
configurations with minimal changes to its configuration.
- Periodic logging.
- Ease of installation.
The BCM includes the capability to log battery parameters during discharge
- Compact design.
and on a periodic time basis.
Mechanical
Dimensions, W, H, D: 80mm , 145mm, 27mm
Weight: 100g
Part Number
Battery Condition Monitor: ASM-ABM-24
AC MAINS MONITOR
The AC mains monitor can be added to the SM range of supervisory modules if - Compatible with SM range
AC supply metering is required. of supervisory modules.
- Ease of installation.
- Compact design.
Communications: Enatel serial bus interface.
Mechanical
Dimensions, W, H, D: 145mm, 15mm, 85mm
Weight: 61.5g
Part Number
AC Mains Mointor: ASM-AC3P
Enatel have recognised the need for DC Power Supplies specifically sized The SOHO (Small Office/Home Office) and residential market is going to have
for Fibre to the Home requirements and developed a range of standalone and the largest requirement for DC systems. If the customer premise is fitted
modular rectifiers and Micro Compact Power Shelves to suit every application with alarms, nurse call or any other monitored device they will need a battery
within the FTTX environment. Be it Central Office or Customer Premise we backed DC supply to ensure communication is available during an AC outage.
have the power solution to fit.
Experience shows that the majority of Central Office OLT units have a power For the SOHO Client Enatel’s nSURE NS300-12 can provide long term
consumption of up to 1600W. backup for all their communications needs.
Enatel’s Micro Compact Power System is perfect for this application having SOHO (Small Office/Home Office) clients with security systems will need
3 x 800W rectifiers gives an N+1 redundancy solution, built in distribution Enatel’s nSURE NS300-12 power supply. Couple into this the ONU, Security
and full configured Supervisory Module. system, residential gateway and wireless router and it can be business as
usual from a laptop during an AC outage. The NS300-12 is wall mountable
and convection cooled making it ideal for office locations.
OFFICE / APARTMENT APPLICATIONS
- 12V, 300W output.
These ONT’s range in power consumption from 60W to 500W, typically have - Mains fail alarm.
dual DC feeds and are 19” rack mountable. - Convection cooled.
- Wall mountable.
Enatel’s Micro Compact range with 200W and 400W modules are purpose - Automatic float/boost charge cycle.
built for this application, giving optimum power output with space for - Power factor corrected.
redundancy and standby battery recharge in the event of an AC failure. - Thermally protected.
- Input/output voltage and current protected.
MICRO COMPACT POWER SYSTEM
nSURE NS30-12
Enatel’s new range of Micro Compact Power Systems utilize Enatel’s
intelligent controllers and modular rectifiers. With rectifier output ratings To suit the residential needs Enatel offers the nSURE NS30-12 (with
of 200, 400 and 800W and Supervisory modules capable of Ethernet integrated battery) for basic autodialer backup functionality.
communication as standard these 1U power shelves are ideal for FTTX
solutions. They offer output power in line with the OLT /ONU usage and For home owners with alarm auto dialers FTTH means their alarms will not be
have the capacity for N+1 redundancy. With various output distribution monitored in the event of an AC Outage. Enatel’s nSURE NS30-12 provides
options they cater to all the requirements of this growing market. battery backed power to the ONU even when the lights go out. Security or
Nurse call devices will operate as normal.
- Micro compact size means more room
for revenue generating equipment. - Telecom grade 12V DC (30W max.) output.
- World leading power density. - Up to 8 hours* of standby battery backup.
- Fully featured telecom grade rectifiers. - Flexibility of wall or desktop mount.
- Network monitoring available.
- Easy user replaceable battery without power interruption.
- Modular 19”/515mm ETSI design for ease of installation.
- Microprocessor based intelligent control.
- High reliability means less cost of maintenance.
- Cold start capable.
- Full remote monitoring available
- Local audible and visual indicators with remote alarms.
means less site visits and less cost.
- Optional extended runtime.
- Easily customized and configured to
suit each customers individual needs.
AC POWER SOLUTIONS
48
AC Input: Single phase.
2.4
Termination: Single phase, 1.5m flying lead.
DC Output
Rated System Output Power: 2400W max. (50A @ -48V; 44.4A @ -54.0V)
kW
maximum output power.
Polarity: Positive earth. (negative earth available to special order).
DC Distribution:
Breaker Fail Detection: Electronic fail detection on both load and battery breakers.
Low Voltage Disconnect: 50A battery LVD (magnetically latching) fitted as standard.
Mechanical
Monitoring & Control: Various monitoring options are available via the Enatel SM35/36 series
Accessories
ACA-BC08P2: 2m, 8mm Ø battery cable kit. (other lengths available to special order)
12
AC Input
Nominal: 110/220V, 50/60Hz
Voltage Range: 100-275V AC (full power output),
85-100V AC (reduced power output)
V Frequency Range:
Power Factor:
45-66Hz
>0.99 (full load)
nominal output voltage. Efficiency: 85%
Input Fuses: HRC Fuses in phase & neutral.
Maximum Input Current: 4A
300
Protection:
Input Voltage: Automatic shutdown,
restarts automatically when correct voltage restored.
Input Rush: <2x maximum input current.
W DC Output
Nominal Voltage: 12V
maximum output power.
Rated Voltage: 14.5V
Voltage Range: 11.5-15V
Maximum Current: 20A
Regulation:
Line: ±0.1%
Load: ±0.5% (no load to full load)
Hold-up Time: >15ms for 20% output voltage drop.
Start-up Time: Walk-in delay 2 seconds (depends on AC input voltage)
Protection:
Current Limit: Adjustable to 50-100% of maximum rated current.
Over Temp: Automatic current turndown, backup shutdown protection.
Polarity Reversal: Output fuse with crowbar diode.
Over Voltage: Adjustable limit.
Noise: (under nominal conditions)
Ripple <100Hz: <5mV rms unweighted.
Voice Band 100Hz to 5KHz: <0.5mV rms psophometric.
Wide Band 5kHz to 1 MHz: <2.5mV rms unweighted.
Peak to Peak 0 to 20MHz: <50mV p-p unweighted.
Isolation:
Input to Output: 3000V AC
Input to Chassis: 2500V AC (VDR to chassis removed.)
Output to Chassis: 1500V AC
Environmental Requirements
Nominal Ambient Temperature: 25+/-5°C
Range: -10 to +60°C
Humidity: 5-95% RH (non-condensing)
Altitude: <2500m de-rate maximum ambient temperature
by +4˚ per 1000m above sea level.
Mechanical
Dimensions, W, H, D: 311mm, 163mm, 62mm
Weight: 1.5kg
Shipping Dimensions, W, H, D: 377mm, 235mm, 122mm
Shipping Weight: 2.4kg
Cooling: Convection cooled.
Connections:
Mains: IEC 320 universal connection.
Output to Load: 4 way lumberg macromodule.
Output to batteries: 4 way lumberg macromodule.
Standard Features
Auto Float/Boost: Rectifier enters boost mode at power up.
When battery current reduces to float threshold limit (adjustable from
0.1A to 40% MRC), unit reverts to float voltage setting. When in boost
but out of current limit, rectifier will automatically switch back to float
after approximately four hours.
If battery current exceeds the float threshold limit when the rectifier is
in float mode it will automatically switch to boost mode.
Alarm and Indicator Controls: Open collector rectifier fail (via 4k7 resistor), Open collector mains fail.
Compliances:
Safety: EN60950
Electrostatic Discharge: CISPR24
Radiated Radio Frequency: CISPR22
AC Harmonics: EN61000-3-2
AC Flicker and Fluctuation: EN61000-3-3
12
Input
30
Output
Battery
Recharge Time (Internal Battery): 4 hours to 90% without load after discharge.
Indicators
Audible Alarm
Fault: Continuous.
Environment
Physical
Weight: 4.0Kg
- World leading power density. Based on our proven range of modular telecom power solutions, we have
- Fully featured telecom developed a range of solutions for use in 110V DC industrial applications.
grade rectifiers.
- Network monitoring available. Systems are configured using Enatel’s state of the art high frequency switch
- Modular 19” design for ease mode rectifier modules, intelligent network capable controllers, AC & DC
of installation.
distribution modules, and cabinets, and can be customized and configured to
- Includes AC surge protection.
meet individual customer requirements.
- More room for revenue
creating equipment.
For details on a Enatel power system that meets your requirements contact us.
- Upgrade existing systems
to higher power.
- High reliability means less cost
of maintenance.
- Full remote monitoring available
means less site visits and less cost.
- Cost competitive.
- Suitable for more harsh
environments.
110
AC Input: Single phase 90 – 300V AC
AC Current: 38A max / Ph (Ph-N) (refer to RM30110 brochure for full details)
6.0
Termination: Single phase, 16mm2 L, N, E tunnel terminals at rear.
DC Output kW
maximum output power.
Nominal Voltage: 121.5V
DC Distribution:
Mechanical
Dimensions, W, H, D: 482.6mm (standard 19” module), 89mm (1U, 3.5”), 415mm (16.3”)
Monitoring & Control: Various monitoring options are available via the Enatel SM33/34 series of
110
AC Input: Single phase with surge protection and input 32A MCB
V
Frequency Range: 45-66Hz
nominal output voltage.
3.0
Termination: Single phase. Direct MCB termination for L. 10mm² N, E tunnel terminals.
DC Distribution:
Monitoring and Control: Various monitoring options via the Enatel SM30 series of control &
110
AC Input
Nominal: 230V
Voltage Range: 90-300V (reduced power below 175V)
Frequency Range: 45-65 Hz
Power Factor: >0.99 V
Efficiency: >92% (>45% output power) nominal output voltage.
Input Fuses: HRC fuses in phase and neutral.
Maximum Input Current: 19A
3.0
Protection:
Input Voltage: Auto shutdown, auto restart when correct voltage restored.
Input Inrush: <2x maximum input current.
DC Output
kW
Output Ratings:
Constant Current: 80-110V DC (27.3A)
nominal output power.
Constant Power: 110-155VD C (3.0kW)
27.3
Nominal Voltage: 120V
Rated Voltage: 145V
Voltage Range: 80-155V
Maximum Current: 27.3A
Regulation:
Line: ±0.1% A
Load: ±0.5% (no load to full load) maximum output current.
Hold-up Time: >15ms for 20% output voltage drop.
Start-up Time: Start up delay 1 second. (varies with AC supply voltage)
Walk-in delay 6 seconds at full output. (varies with DC output voltage)
Protection:
Current Limit: Adjustable to 50-100% of maximum rated current.
Over Temperature: Automatic current turndown, backup shutdown protection.
Polarity Reversal: Output fuse with crowbar diode.
Over voltage: Adjustable limit.
Noise: (under nominal conditions)
Ripple <100Hz: <1mV rms unweighted.
Voice band 100Hz-5KHz: <2mV rms psophometric.
Wide band 5kHz-1MHz: <5mV rms unweighted
Peak to Peak 0-20MHz: <200mV peak to peak.
Isolation:
Input to Output: 4000V DC
Input to Chassis: 3500V DC (VDR to chassis removed)
Output to Chassis: 2100V DC
Environmental Requirements
Ambient Temperature:
Nominal: 25+/-5ºC
Range: -10ºC to +70ºC (maximum output power is derated above +50ºC)
Storage Temperature: -20ºC to +70ºC
Humidity: 5-95% RH (non-condensing)
Altitude: <2500m, De-rate maximum ambient temperature
by 4ºC per 1000m above sea level.
Mechanical
Dimensions, W, H, D: 41mm, 220mm, 305mm overall.
Weight: 2.8kg
Shipping Dimensions W, H, D: 52mm, 230mm, 340mm
Shipping Weight: 2.95kg
Cooling: Forced cooled, using dual temperature controlled high reliability fans.
Compliances
Safety: EN60950
Electrostatic Discharge: CISPR24
Radiated Radio Frequency: CISPR22
AC Harmonics: EN61000-3-2
AC Flicker and Fluctuation: EN61000-3-3
Other: CE & RoHS compliant.
LVD
Input
Voltage: 80-160V DC
Current: <50mA maximum.
Interface
dual lvd control. Display: 4 line x 16 character multi-lingual alpha numeric display.
Communications:
WEB
Serial: 1x USB port on front panel for local PC interface.
1x RS232 port, rear mounted for remote serial/modem communications.
Relay: 3x alarm and control relays, two of which
can be mapped for customized alarm settings.
TCP/IP: Ethernet interface for communication using SNMP
protocol and internal web based configurator.
web based configurator. LVD: 3x standard or 2x pulse control LVD contacts.
(for magnetically latched LVD contactors)
USB
Indicators:
3x LED’s Green - power on/monitor OK.
Yellow - non urgent alarm.
Red - urgent alarm.
Audible: 90dBA buzzer mappable to user defined conditions.
Controls: 3x push buttons for parameter setting or viewing on front panel.
usb port for local connection. Signal Inputs: Serial bus for rectifier control and interface to peripheral modules.
Fuse fail.
5x spare digital inputs.
2x temperature sensors.
3x current shunts.
2x DC voltage inputs.
Alarms: 3x alarm relays.
Alarm Contacts: 0.3A 100V volts free changeover contacts or
0.15A 160V volts free changeover contacts.
Default Alarm Map: Urgent.
Non-urgent.
Monitor fail.
Logging Capacity:
Periodic Log: 16384 records. (dependant on number of parameters logged.)
Event Log: 16384 records. (dependant on number of parameters logged.)
Physical
Dimensions, W, H, D: 111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)
Weight: 1.5kg
Connections: Relay outputs, mini combicon to accept 1.5mm csa wire.
Serial communications to rectifier shelf & peripheral devices - RJ45.
USB port - USB mini B.
Operating Temperature: -25 to +55°C
Storage Temperature: -50 to +85°C
Compliances
Radiated Emissions: EN55022
RF Susceptibility: EN55024
Optional Accessories
ACA-TC3C: 3m temperature sensor and cable.
ACA-TC3C: 7m temperature sensor and cable.
ASM-AC3P110: 3 phase AC voltage and current monitor.
ASM-ABM-24: Battery condition monitor, 24 blocks. (maximum 4x BCM cards.)
Part Numbers
SM34-00: Standard 1U modular controller, 3x relays, 6x digital inputs.
SM34-00-1U: Standard 1U x 19” mounting version controller, 3x relays, 6x digital inputs.
SM34-00-PM: Standard panel mount version controller, 3x relays, 6x digital inputs.
126
Input
Voltage: 80-160V DC
Current: <50mA maximum.
Interface
serial control for up to 126 rectifiers/
Display: 4 line x 16 character multi-lingual alpha numeric display.
Communications:
converters plus peripheral devices.
LCD
Serial: 1x USB port on front panel for local PC interface.
Relay: 3x alarm and control relays, two of which
can be mapped for customized alarm settings.
LVD: 3x standard or 2x pulse control LVD contacts.
(for magnetically latched LVD contactors)
Indicators:
lcd display.
3x LED’s Green - power on/monitor OK.
USB
Yellow - non urgent alarm.
Red - urgent alarm.
Audible: 90dBA buzzer mappable to user defined conditions.
Controls: 3x push buttons for parameter setting or viewing on front panel.
Signal Inputs: 2x serial buses for rectifier control and interface to peripheral modules.
Fuse fail.
5x spare digital inputs. usb port for local connection.
2x temperature sensors.
3x current shunts.
2x DC voltage inputs.
Alarms: 3x alarm relays.
Alarm Contacts: 0.3A 100V volts free changeover contacts or
0.15A 160V volts free changeover contacts.
Default Alarm Map: Urgent.
Non-urgent.
Monitor fail.
Logging Capacity:
Periodic Log: 16384 records. (dependant on number of parameters logged.)
Event Log: 16384 records. (dependant on number of parameters logged.)
Physical
Dimensions, W, H, D: 111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)
Weight: 1.5kg
Connections: Relay outputs, mini combicon to accept 1.5mm csa wire.
Serial communications to rectifier shelf & peripheral devices - RJ45.
USB port - USB mini B.
Operating Temperature: -25 to +55°C
Storage Temperature: -50 to +85°C
Compliances
Radiated Emissions: EN55022
RF Susceptibility: EN55024
Optional Accessories
ACA-TC3C: 3m temperature sensor and cable.
ACA-TC7C: 7m temperature sensor and cable.
ASM-AC3P110: 3 phase AC voltage and current monitor.
ASM-ABM-24: Battery condition monitor, 24 blocks. (maximum 4x BCM cards.)
Part Numbers
SM33-00: Standard 1U modular controller, 3x relays, 6x digital inputs.
SM33-00-1U: Standard 1U x 19” mounting version controller, 3x relays, 6x digital inputs.
SM33-00-PM: Standard panel mount version controller, 3x relays, 6x digital inputs.