Titre : SSLL10 - Portique à liaisons latérales Date : 01/08/2011 Page : 1/6
Responsable : FLÉJOU Jean-Luc Clé : V3.01.010 Révision :
03292bcced55
Summary:
Static test in linear elasticity, being used to validate the elements of right beam POU_D_T for a specific loading
and a loading distributed (keyword FORCE_POUTRE).
The relations and moments bending are tested.
Warning : The translation process used on this website is a "Machine Translation". It may be imprecise and inaccurate in whole or in part and is
provided as a convenience.
Copyright 2020 EDF R&D - Licensed under the terms of the GNU FDL (http://www.gnu.org/copyleft/fdl.html)
Version
Code_Aster default
Titre : SSLL10 - Portique à liaisons latérales Date : 01/08/2011 Page : 2/6
Responsable : FLÉJOU Jean-Luc Clé : V3.01.010 Révision :
03292bcced55
1 Problem of reference
1.1 Geometry
Problem plan
G is in the middle of DA .
Another characteristic of the beams not being used for calculations: the beams are of square section.
−4
AAB =16 10 m
−4
A AD=1 10 m
A AC =1 10−4 m
AAE =4 10−4 m
Warning : The translation process used on this website is a "Machine Translation". It may be imprecise and inaccurate in whole or in part and is
provided as a convenience.
Copyright 2020 EDF R&D - Licensed under the terms of the GNU FDL (http://www.gnu.org/copyleft/fdl.html)
Version
Code_Aster default
Titre : SSLL10 - Portique à liaisons latérales Date : 01/08/2011 Page : 3/6
Responsable : FLÉJOU Jean-Luc Clé : V3.01.010 Révision :
03292bcced55
Warning : The translation process used on this website is a "Machine Translation". It may be imprecise and inaccurate in whole or in part and is
provided as a convenience.
Copyright 2020 EDF R&D - Licensed under the terms of the GNU FDL (http://www.gnu.org/copyleft/fdl.html)
Version
Code_Aster default
Titre : SSLL10 - Portique à liaisons latérales Date : 01/08/2011 Page : 4/6
Responsable : FLÉJOU Jean-Luc Clé : V3.01.010 Révision :
03292bcced55
2 Reference solution
2.1 Method of calculating used for the reference solution
One poses:
EI An
k An=
l An
with n=B , C , D or E
3
K=k ABk ADk AE k AC
4
k An
r An=
K
with n=B , C , D or E
2
Fl AD pl AB
C 1= −
8 12
• Rotation in A :
C1
=
4K
• Moment in A :
pl 2AB
M AB= r AB .C 1
12
Fl
M AD=− AD r AD .C 1
8
M AE =r AE . C 1
M AC =r AC . C 1
Warning : The translation process used on this website is a "Machine Translation". It may be imprecise and inaccurate in whole or in part and is
provided as a convenience.
Copyright 2020 EDF R&D - Licensed under the terms of the GNU FDL (http://www.gnu.org/copyleft/fdl.html)
Version
Code_Aster default
Titre : SSLL10 - Portique à liaisons latérales Date : 01/08/2011 Page : 5/6
Responsable : FLÉJOU Jean-Luc Clé : V3.01.010 Révision :
03292bcced55
3 Modeling A
3.1 Characteristics of modeling
Elements POU_D_T
1 element for the section AG
1 element for the section GD
1 element for the section AE
1 element for the section AC
1 element for the section AB
Boundary conditions:
DDL_IMPO (
TOUT=' OUI', DX=0, DRX=0, DRY=0
NOEUD= (D, B, E), DX=0, DY=0, DRZ=0
NOEUD=C, DX=0, DY=0
)
FORCE_NODALE NOEUD=G Fy = -1. 105
FORCE_AUTRE MAILLE=AB Fy = -1. 103
Warning : The translation process used on this website is a "Machine Translation". It may be imprecise and inaccurate in whole or in part and is
provided as a convenience.
Copyright 2020 EDF R&D - Licensed under the terms of the GNU FDL (http://www.gnu.org/copyleft/fdl.html)
Version
Code_Aster default
Titre : SSLL10 - Portique à liaisons latérales Date : 01/08/2011 Page : 6/6
Responsable : FLÉJOU Jean-Luc Clé : V3.01.010 Révision :
03292bcced55