Sei sulla pagina 1di 10

FACTOR DE MASA PARTICIPAT

Period
Case Mode UX UY UZ Sum UX Sum UY
sec
Period
Case Mode UX UY UZ Sum UX Sum UY
sec
Modal TY 0.388 0.0456 0.6441 0 0.0456 0.6441
Modal TZ 0.348 0.2834 0.0385 0 0.3291 0.6826
Modal TX 0.288 0.3724 0.0115 0 0.7015 0.6941
Modal 4 0.089 0.0448 0.1123 0 0.7463 0.8064
Modal 5 0.083 0.0313 0.0725 0 0.7776 0.8789
Modal 6 0.067 0.1182 0.0059 0 0.8958 0.8848
Modal 7 0.04 0.0219 0.0186 0 0.9177 0.9034
Modal 8 0.037 0.0032 0.0451 0 0.9209 0.9485
Modal 9 0.031 0.0331 0.0025 0 0.954 0.951
Modal 10 0.025 0.0125 0.0048 0 0.9665 0.9558
Modal 11 0.023 0.0006 0.0233 0 0.9671 0.9791
Modal 12 0.019 0.0127 0.001 0 0.9798 0.9802
Modal 13 0.018 0.0071 0.0011 0 0.9869 0.9813
Modal 14 0.017 2.34E-05 0.0117 0 0.9869 0.9929
Modal 15 0.015 0.0045 0.0004 0 0.9914 0.9933
Modal 16 0.014 0.0041 1.00E-05 0 0.9956 0.9933
Modal 17 0.014 0.0002 0.0052 0 0.9957 0.9985

Modal 18 0.013 0.0007 0.0001 0 0.9964 0.9986


Modal 19 0.012 0.0002 0.0012 0 0.9965 0.9998
Modal 20 0.012 0.0025 1.25E-05 0 0.9991 0.9999
Modal 21 0.011 0.0006 2.43E-06 0 0.9997 0.9999

PESO DE LA EDIFICACIÓN
P VX VY T MX
Story Load Case/Combo Location
tonf tonf tonf tonf-m tonf-m
TECHO 7 PESO Bottom 240.4593 0 0 0 2893.3577
TECHO 6 PESO Bottom 480.9186 0 0 0 5786.7154
TECHO 5 PESO Bottom 721.3779 0 0 0 8680.0732
TECHO 4 PESO Bottom 961.8372 0 0 0 11573.4309
TECHO 3 PESO Bottom 1202.2965 0 0 0 14466.7886
TECHO 2 PESO Bottom 1442.7558 0 0 0 17360.1463
TECHO 1 PESO Bottom 1683.2151 0 0 0 20253.504
NOTA: SE ASUMIO PARA CM:

PESO LADRILLO (TECHO) 72KG/M2 PARA TODOS LOS PISOS


PISO TERMINADO 100 KG/M2 PARA TODOS LOS PISOS

SE ASUMIO PARA CV:


SOBRECARGA 200KG/M2 PARA TODOS LOS PISOS
SA PARTICIPATIVA

Sum UZ RX RY RZ Sum RX Sum RY Sum RZ

Sum UZ RX RY RZ Sum RX Sum RY Sum RZ

0 0.3315 0.0223 0.0062 0.3315 0.0223 0.0062


0 0.0201 0.1382 0.3868 0.3516 0.1605 0.393
0 0.0063 0.19 0.3165 0.3579 0.3505 0.7095
0 0.208 0.0914 0.0274 0.5659 0.4419 0.7369
0 0.1315 0.0619 0.0815 0.6974 0.5038 0.8184
0 0.0107 0.2235 0.0695 0.708 0.7273 0.8879
0 0.0416 0.0512 0.0206 0.7497 0.7785 0.9085
0 0.1032 0.0077 0.017 0.8529 0.7862 0.9255
0 0.0058 0.0789 0.0263 0.8587 0.8651 0.9518
0 0.0132 0.0359 0.0107 0.8719 0.9009 0.9625
0 0.0657 0.0017 0.0048 0.9376 0.9027 0.9672
0 0.003 0.0366 0.0133 0.9406 0.9393 0.9805
0 0.0031 0.0207 0.0054 0.9437 0.96 0.9859
0 0.0344 0.0001 0.0012 0.9781 0.9601 0.9871
0 0.0012 0.0135 0.0069 0.9793 0.9736 0.994
0 2.32E-05 0.0126 0.002 0.9793 0.9862 0.996
0 0.016 0.0005 0.0001 0.9953 0.9867 0.996

0 0.0004 0.002 0.0008 0.9958 0.9887 0.9968


0 0.0038 0.0005 0.0002 0.9995 0.9892 0.997
0 4.40E-05 0.0079 0.0022 0.9996 0.9971 0.9992
0 8.65E-06 0.002 0.0005 0.9996 0.9991 0.9998

PESO POR
MY
PISO
tonf-m TON
-1608.9405 240.4593
-3217.8809 240.46
-4826.8214 240.46
-6435.7618 240.46
-8044.7023 240.46
-9653.6428 240.46
-11262.5832 240.46
1683.2151 TON
AREA = 310.57 M2
PESO TIPICO 240.46 TON
RATIO= 0.77425379 TON/M2
ANÁLISIS SISMICO ESTÁTICO

Tx= 0.288 s
Z= 0.35 Zona 3
U= 1 Uso Vivienda C
S= 1.15 Suelo Intermedio
TP= 0.6 S2
TL= 2 S2
Cx= 2.5
Rx=Ro*Ia*Ip 7 Ro=7
Ia= 1
Ip= 1
Cx/Rx>0.11 0.3571429 Cumple

Peso Edific= 1683.2151 ton


Ve=ZUCS/R 0.14375 Coeficiente
VXX=ZUCS/R*Pe 241.96217 TON 241.96217

ANÁLISIS SISMICO DINAMICO


Load P VX VY
Story Location
Case/Combo
tonf tonf tonf
TECHO 7 SDXX Max Bottom 0 24.7355 8.5662
TECHO 7 SDYY Max Bottom 0 8.4183 31.2509
TECHO 6 SDXX Max Bottom 0 47.4897 15.8087
TECHO 6 SDYY Max Bottom 0 15.5837 59.6537
TECHO 5 SDXX Max Bottom 0 64.5665 21.0626
TECHO 5 SDYY Max Bottom 0 20.8283 81.1468
TECHO 4 SDXX Max Bottom 0 77.4911 25.1005
TECHO 4 SDYY Max Bottom 0 24.891 97.3475
TECHO 3 SDXX Max Bottom 0 86.9883 28.2158
TECHO 3 SDYY Max Bottom 0 28.0572 108.98
TECHO 2 SDXX Max Bottom 0 93.2107 30.3546
TECHO 2 SDYY Max Bottom 0 30.2928 116.2948
TECHO 1 SDXX Max Bottom 0 96.0684 31.3174
TECHO 1 SDYY Max Bottom 0 31.3174 119.4815
TY= 0.388 s
Z= 0.35 Zona 3-Hyo
U= 1 Uso Vivienda C
S= 1.15 Suelo Intermedio
TP= 0.6 S2
TL= 2 S2
CY= 2.5
RY=Ro*Ia*Ip 7 Ro=7
Ia= 1
Ip= 1
Cx/Ry>0.11 0.3571429 Cumple

Peso Edific= 1683.2151 ton


Ve=ZUCS/R 0.14375 Coeficiente
VYY=ZUCS/R*P241.96217 TON

T MX MY

tonf-m tonf-m tonf-m


337.1216 25.6987 74.2064
278.8608 93.7527 25.255
645.0292 72.608 215.746
531.2886 271.1402 71.4528
874.5517 134.2851 406.4613
721.6242 510.5671 132.3407
1048.9882 206.8074 633.351
865.6352 795.7862 204.1449
1178.7607 287.5011 886.154
970.142 1113.2986 284.2505
1264.8478 374.0243 1156.0038
1036.932 1451.2339 370.3767
1304.2784 463.935 1434.8233
1065.8897 1799.3331 460.0638
Story Load Case/Combo Direction Drift Label X Y Z
TECHO 7 DERIVA XX X 0.000458 31 10 0 21
TECHO 6 DERIVA XX X 0.000425 33 7.5 0 18
TECHO 5 DERIVA XX X 0.00038 33 7.5 0 15
TECHO 4 DERIVA XX X 0.000319 33 7.5 0 12
TECHO 3 DERIVA XX X 0.000243 33 7.5 0 9
TECHO 2 DERIVA XX X 0.000156 33 7.5 0 6
TECHO 1 DERIVA XX X 5.50E-05 31 10 0 3

ESTAS DERIVAS YA HAN SIDO MULTIPLICADAS POR 0.75R EN EL ETABS, POR


NOTA: SER UNA EDIFICACION REGULAR, YA QUE Ia=1 y Ip=1; POR LO TANTO SERA
0.75*7 = 5.25
Load
Story Case/Comb Direction Drift Label X Y Z
o
TECHO 7 DERIVA YY Y 0.000172 30 15 18 21
TECHO 6 DERIVA YY Y 0.000155 13 15 12 18
TECHO 5 DERIVA YY Y 0.000137 30 15 18 15
TECHO 4 DERIVA YY Y 0.00011 13 15 12 12
TECHO 3 DERIVA YY Y 7.90E-05 30 15 18 9
TECHO 2 DERIVA YY Y 4.70E-05 13 15 12 6
TECHO 1 DERIVA YY Y 1.60E-05 30 15 18 3

ESTAS DERIVAS YA HAN SIDO MULTIPLICADAS POR 0.75R EN EL ETABS,


NOTA: POR SER UNA EDIFICACION REGULAR, YA QUE Ia=1 y Ip=1; POR LO
TANTO SERA 0.75*7 = 5.25