SCREENING FOR FLOW INDUCED TURBULENCE

System: RIMA DWD PUMP P-13101 DISCARGE LINE

Line No: 16"-W13452-15832

Below evaluation follows the "EI Guideleines for the Avoidance of Vibration Induced Fatigue Failure in Process Pipework", 2nd edition

Input

Outside dia. Of pipe D 406.4 mm

wall thickness of pipe T 26.19 mm

Density of fluid ρ 1000 kg/m3

Velocity of fluid v 2.65 m/s

Natural frequency fn 3 Hz (From CAESAR II CALCULATION)

Gas dynamic Viscosity µ - Pa.S (Applicable for only gas system)

Fluid type Liquid (Gas/Liquid/Multiphase)

According to table T2-1, Guideline for Support arrangement given with repsect to Natural frequncy of system as below:

Support Arrangement Natural Frequency

Stiff 14 to 16 Hz
Medium Stiff 7Hz
Medium 4Hz
Flexible 1Hz

Flow Induced Vibration Factor (Fv): (Reference Section T.2.2.3.4, Table T2-2)

Stiffness:= Flexible

According to table, A-4:

α = 770271.74 if stiffness = stiff

434289 if stiffness = Medium stiff

235349.6 if stiffness = Medium (273 <=D<=762)

NA if stiffness = Medium (60 <=D<=219)

66144.75 if stiffness = Flexible (273 <=D<=762)

NA if stiffness = Flexible (60 <=D<=219)


SCREENING FOR FLOW INDUCED TURBULENCE

System: RIMA DWD PUMP P-13101 DISCARGE LINE

Line No: 16"-W13452-15832

α = 66144.75
SCREENING FOR FLOW INDUCED TURBULENCE

System: RIMA DWD PUMP P-13101 DISCARGE LINE

Line No: 16"-W13452-15832

β = -0.78 if stiffness = stiff

-0.84 if stiffness = Medium stiff

-0.84 if stiffness = Medium (273 <=D<=762)

NA if stiffness = Medium (60 <=D<=219)

-0.9 if stiffness = Flexible (273 <=D<=762)

NA if stiffness = Flexible (60 <=D<=219)

β = -0.9

Fv NA if stiffness = stiff

NA if stiffness = Medium stiff

NA if stiffness = Medium (273 <=D<=762)

NA if stiffness = Medium (60 <=D<=219)

5607.37 if stiffness = Flexible (273 <=D<=762)

NA if stiffness = Flexible (60 <=D<=219)

Flow induced vibration number, Fv:

Fv = 5607.37

Fluid Viscosity Factor (FVF): (Reference Section T.2.2.3.2)

FVF 1 (FVF is 1.0 for Liquid and Multiphase Fluids)

Flow Induced Turbulance LOF: (Reference Section T.2.2.3.5)

The likelihood of failure, LOF:

LOF = 1.26

Recommendations: (As per Table 3-1)

As per Table 3-1, for LOF= 1.26

Small Bore Connection on Main line should be assesed as per Section T3.

A Visual survey shuold be undertaken to check poor construction and/or Gerometry and/or support for main line and/or potential vibration
transmission from other sources. (As per Section T-5)