PROBLEM SET NO.

DIRECTIONS: Solve for the unknown values Z2 and Z3 are connected in parallel and
for each problem, with complete solutions, the combination is connected in series
draw the illustration and unit. Use engineering with impedance Z1 across 120 V single
lettering and ruler for straight lines. Box and phase 60 Hz source. Find the total
round your final answer only into four decimal power drawn by the impedances.
places. Afterwards, capture your solution and
9. Two parallel branches have admittances
paste in Microsoft Excel. Retype the following
0.3 + j0.4 and 0.2 – j0.25, respectively.
question.
If the current in the first branch is 10 A,
Format: Question, Solution determine the total current supplied to
FileName: Surname, Initial_Subject_PSET NO. the parallel combination.
Ex:Fruelda, SJ_Circuits II_PSET 2 10. What value of resistance should be
placed in parallel with a 50 micro-farad
1. A 50 micro-farad capacitor is connected capacitor in order to have a total power
in series with a 50 ohm resistor. What is factor of 0.8 on a 60-cycle AC system?
power if the source voltage is e = 100 11. The impedance coil absorbs 250 watts
sin(377t + 300) V? when connected across 220 V, 60 Hz
2. The metering of a power customer was mains. It is then connected across 110
read and gave the following data: kW-hr V, 25 Hz mains and also absorbs 250
= 200,000: kVAR-hr = 180,000: watts. What is the inductance of the
Maximum demand = 380 kW; Billing coil?
days = 30. What is the average power 12. A capacitor is rated 100 kVAR, 380
factor of the customer? volts, 50 Hz. What will its rating be at
3. The voltage of a source is e = 220 sin 60 Hz, 220 volts?
(wt + 300) while its three loads take 13. A single phase inductive load takes 50
currents given by their equations: ia = kVA at 0.60 power factor lagging. Solve
3.2 sin(wt + 300); ib = 2.8 sin(wt – 600); for the kVAR of a capacitor required to
ic = 4.7 sin wt. What is the total power improve the power factor to 1.0
components supplied by the source? 14. A factory draws a lagging load of 2000
4. A coil of 50-ohm resistance and of 150 kW at a power factor of 60% from a 6
mH inductance is connected in parallel kV bus line. A synchronous capacitor
with a 50 micro-farad capacitor. The losses are 275 kW, calculate the
source voltage is 100 sin(377t + 300). operating power factor of the
What is the equation of the line current? synchronous capacitor.
5. An inductor L1 is connected in series 15. An alternator rated 530-kVA, is
with a parallel combination of inductor operating at 0.60 pf lagging. A
L2 and capacitor C. The impedance of synchronous condenser is parallel to
the circuit w = 400 rad/sec is j100 ohms. improve the pf to 90% lagging.
The circuit is to yield infinite impedance Determine the operating power factor of
at w = 1000 rad/sec and zero impedance the synchronous condenser. Assume the
at w = 2,000 rad/sec. Determine the alternator is not supposed to be
value of C. overloaded.
6. A 1-hp, 220 V, 60 Hz capacitor-start
motor has main and auxiliary winding
impedance at starting of 3.5 + j2.5 ohms
and 8.6 + j2.5 ohms, respectively.
Determine the value of the starting
capacitance that will place the main and
auxiliary winding currents 900 apart at
starting.
7. Two impedances A and B are connected
in parallel across a 120 V ac supply. The
total current and the current in each
impedance are adjusted to 20 A. The
power drawn by A is doubled that of B
and the power factor is lagging.
Determine the power factor of A.
8. Given three impedances: Z1 = 10 + j0,
Z2 = 3 + j4 and Z3 = 8 – j6. Impedance