3–1600 A
For any soft start situation
VLT® Soft Starters cover the full range – from simple
start-stop operation to high end performance.
www.danfoss.com/drives
Soft starts: Protect gear, goods,
equipment and the environment
An AC motor switched directly on to In some VLT® Soft Starters, current
the mains power supply will struggle transformers measure the motor cur- MCD 100:
to reach its nominal speed as quickly rent, providing feedback for starting • Micro Soft Start controller for
as possible. current control but also for numerous motors up to 11 kW
motor and application protection • Extremely robust SCR design
This draws maximum current from functions. with heavy ratings as standard
the power supply and accelerates the • Unlimited number of starts
application with its maximum torque. per hour
Depending on the application, this VLT® Soft Starters cover • Contactor style design for
can cause different problems. a comprehensive range easy selection, installation and
Soft starting and stopping can be commissioning
Applications like pumps, conveyers, controlled in a number of ways
centrifuges and bandsaws must be depending on the application. Some MCD 200:
started slowly, and sometimes applications require non-linear volt- • Compact Soft Starter for
stopped slowly, to prevent mechani- age ramp-up and the voltage ramp motors up to 110 kW
cal shocks such as water hammer, is therefore related to the actual cur- • Voltage ramps, current limit start
and intregrated motor protection
and strains on bands, couplings and rent drawn. Conversely, a band-saw
• Integral bypass design reduces
shafts. usually requires a quick stop function
heat dissipation
provided by a DC brake. • Wide power range with advanced
accessory modules
Principle of Phase Then again, a number of applica-
Angle Control tions require a kick-start torque for MCD 500:
A soft starter is an electronic device an instantaneous period of time fol- • Fully featured Soft Starter for
that regulates the voltage to the lowed by a soft ramp-up acceleration. motors up to 850 kW
motor and this provides a smooth VLT® Soft Starters cover all of these • Total motor starting solution
transition from standstill to full speed applications and much more. • Advanced protection features
operation of the application. • Adaptive Acceleration Control
• Inside Delta connection
VLT® Soft Starters all use the principle • 4 line graphical display
of phase angle control: Back-to-back • Multiple programming setup
coupled thyristors ramp up the motor menus
voltage.
Serial communication
MCD 201, MCD 202 and MCD 500 • DeviceNet
come with optional plug-in modules • Profibus
for serial communication. • Modbus RTU
• USB
2
VLT® Soft Starter MCD 500
VLT® Soft Starter MCD 500 is Features Benefits
a total motor starting solu-
User friendly
tion. Current transformers
measure motor current and • Automatically adapts to the chosen
• AAC Adaptive Acceleration Control
starting and stopping profile
provide feedback for control-
• Adjustable bus bars allow for both top and • Space saving, less cable cost
led motor ramp profiles. bottom entry (360 – 1600 A, 160 – 850 kW) and easy retrofitting
• DC injection braking distributed evenly • Less installation cost and
AAC, the Adaptive Acceleration over three phases less stress on the motor
Control, automatically employs the • Smaller soft starter can be selected
best starting and stopping profile for • Inside Delta (6-wire connection)
for the application
the application. Adaptive Acceleration • Log menus, 99 events and trip log provide
• Eases analysis of the application
Control means that for each start and information on events, trips and performance
stop, the soft starter compares and • Auto Reset • Less down-time
adapts the process to the chosen • Jog (slow-speed operation) • Application flexibility
profile best suited to the application. • Allows motors to be used to their
• Second-order thermal model full potential without damage from
The VLT® Soft Starter MCD 500 has a overloading
four-line graphical display and a logic • Save space and wiring compared to
external bypass
keypad making programming easy. • Internal bypass contactors
• Very little heat dissipates when running.
Advanced setup is possible displaying (21 – 215 A, 7,5 – 110 kW)
Eliminates costly external fans, wiring
operational status. or bypass contactors
• Auto-start/stop clock • Application flexibility
Three menu systems: Quick Menu, • Compact size – amongst the smallest • Saves space in cabinets and other
Application Setup and Main Menu in their class application setups
provide optimum programming • Optimum programming approach and
• 4-line graphical display
approach. setup for viewing operational status
• Multiple programming setup (Standard Menu, • Simplifies the programming, but still
Extended Menu, Quick Set) holding to maximum flexibility
The perfect solution, also for • Multiple languages • Serving the whole world
more severe applications:
• Pumps
• Conveyors
• Fans
• Mixers Power range
• Compressors 21 – 1600 A, 7,5 – 850 kW
• Centrifuges (1,2 MW inside Delta Connection)
• Mills Versions for 200 – 690 VAC
• Saws
• And many more
Dimensions
Current rating [A] Weight [kg] Height [mm] Width [mm] Depth [mm] Frame size
21, 37, 43 and 53 4.2
183
68 4.5 295 150 G1
84, 89 and 105 4.9 213
131, 141, 195 and 215 14.9 438 275 250 G2
245 23.9 460 390 279 G3
360, 380 and 428 35
689 430 302 G4
595, 619, 790 and 927 45
1200, 1410 and 1600 120 856 585 364 G5
3
VLT® Compact Starter MCD 200
VLT® Compact Starter MCD 201 MCD 202
MCD 200 from Danfoss MCD 202 provides enhanced
soft start functionality and various
includes two families of soft motor protection features
starters in the power range
from 7.5 – 110 kW.
Remote operation
Remote operation of MCD 201,
MCD 202 and MCD 500 is facili-
tated by the dedicated remote
operator kit.
4
VLT® Soft Starter MCD 100
VLT® Soft Start Controller
MCD 100 is a cost effective Motor torque Ramp-up time Ramp-down time
and extremely compact soft (Voltage) 0.5–10 sec. 0–10 sec.
starter for AC motors up to 100%
11 kW, due to a unique
semiconductor design. “Kick start”
200 msec.
of max. torque
MCD 100 is a true “fit and forget”
product. Selection can be made on
0% Time
the basis of the motor power – exactly
Initial Torque up to
as with traditional contactors. 85% of nominal torque
Dimensions
Power size Rated current Dimensions
Model Approvals
(kW) (Amps) (mm) H x W x D
3 A: 5-5:10
1.5 102x22,5x124
(AC 53b)
15 A: 8-3:
MCD100 7.5 100-3000 110x45x128 UL, CSA, CE
(AC 53a)
25 A: 6-5:100-480
11 110x90x128
(AC 53a)
5
Specifications and
ordering typecodes
VLT® Compact Starter MCD 200 VLT® Soft Starter MCD 500
MCD 2 0 – – T – C V MCD 5 – – T – G X – – C V
Soft start/stop 1
FLC, [A]
Soft start/stop 0021 Bypass indication IP Rating
2
+ protection 0037 B: With Internal 00, IP 00
Bypass Contactor 20, IP 20
0043 C: Without Internal
Nominal Motor kW, 400 V 0053 Bypass Contactor
0068 (Continuous)
E.g. 55 kW 055 0084
110 kW 110 0089 Supply Voltage
0105 T5, 200 – 525 VAC
0131 T7, 380 – 690 VAC
Line Supply Voltage
0141
200 – 440 V 4
0195 Enclosure
200 – 575 V 6 0215 G1, Frame size 1
0245 G2, Frame size 2
G3, Frame size 3
Control Supply Voltage 0360 G4, Frame size 4
0380 G5, Frame size 5
24 V AC/DC 1 (X, not Used)
0428
110 – 240 V AC and 380 – 440 V AC 3 0595
0619
0790
0927
1200 Control Voltage
1410 CV1, 24 VAC or 24 VDC
1600 CV2, 110 or 220 VAC
Size indication for VLT® Compact Starter MCD 200 Size indication for VLT® Soft Starter MCD 500
Rated FLC (40° C, 1000 m),
Power size Rated current Dimensions
Model Approvals outside delta motor connection
(kW) AC-53b* (Amps) (mm)HxWxD Motor
7.5 18 A: 4-6: 354 size Light Medium Heavy
(kW) Frame Starts Max. 300%, 30s, 400%, 20s, 450%, 30s,
15 34 A: 4-6: 354 @ size per FLC Internal Internal Internal
400 V code hour bypass bypass bypass
18 42 A: 4-6: 354 203 x 98 x 165
11 10 23 21 17 15
22 48 A: 4-6: 354
UL 18.5 G1 10 43 37 31 26
30 60 A: 4-6: 354
C – UL 22 (no fan) 10 50 43 37 30
MCD201/ 37 75 A: 4-6: 594 CE
MCD202 25 10 53 53 46 37
CCC
45 85 A: 4-6: 594 215 x 145 x 193 C-tick 30 6 76 68 55 47
55 100 A: 4-6: 594
37 6 97 84 69 58
75 140 A: 4-6: 594 G1
45 6 100 89 74 61
90 170 A: 4-6: 594 240 x 202 x 214 55 6 105 105 95 78
110 200 A: 4-6: 594 55 6 145 131 106 90
* Example: AC53b: 42A: 4-6: 354 starting current max. 4 times FLC (42A) 75 6 170 141 121 97
in 6 seconds. 354 seconds minimum between starts. G2
90 6 200 195 160 134
110 6 220 215 178 149
Motor
size Frame Starts Max. Not Exter- Not Exter- Not Exter-
Size indication for VLT® Soft Starter MCD 100 (kW) size per by- nal by- by- nal by- nal by-
@ FLC passed
code hour pass passed Bypass passed pass
Power size Rated current Dimensions 400 V
Model Approvals
(kW) (Amps) (mm) H x W x D
132 G3x 6 255 245 255 195 201 171 176
3 A: 5-5:10 185 6 360 360 360 303 310 259 263
1.5 102 x 22,5 x 124
(AC 53b)
200 6 380 380 380 348 359 292 299
15 A: 8-3: 220 6 430 428 430 355 368 301 309
MCD100 7.5 100-3000 110 x 45 x 128 UL, CSA, CE
(AC 53a) 315 G4x 6 620 595 620 515 540 419 434
335 6 650 619 650 532 561 437 455
25 A: 6-5:100-480
11 110 x 90 x 128 445 6 790 790 790 694 714 567 579
(AC 53a)
500 6 930 927 930 800 829 644 661
650 6 1200 1200 1200 1135 1200 983 1071
750 G5x 6 1410 1410 1410 1187 1319 1023 1114
850 6 1600 1600 1600 1433 1600 1227 1353
Note: Optimise your selection with WinStart Soft Starter PC tool.
6
Specifications
Type
VLT® Soft Start Controller MCD 100 VLT® Compact Starter MCD 201 VLT® Compact Starter MCD 202 VLT® Soft Starter MCD 500
A true “fit and forget” soft starter for – a physically compact starter provid- – physically similar to MCD 201 but – the total motor starter solution.
DIN rail mount, MCD 100 provides ing basic soft start and stop func- providing enhanced soft start func Provides advanced control methods
basic soft start and stop function tionality tionality and various motor protec- for starting and stopping and protec-
tion functions tion of motor and application
Concept
Soft start Soft start Current limit start Enhanced soft start and soft stop
Soft stop Soft stop Soft stop Motor and system protection
0.1 – 11 kW @ 400 V 7.5 – 110 kW @ 400 V Motor protection 7.5 – 850 kW @ 400 V (21-1600A)
208 – 600 V mains voltage 200 – 575 V mains voltage 7.5 – 110 kW @ 400 V 200 – 690 V mains voltage
24 – 480 V AC/DC 110 – 440 V AC or 200 – 575 V mains voltage 110 – 220 V AC or
control voltage 24 V AC/DC control supply 110 – 440 V AC or 24V AC/DC control supply
2-phase SCR control 2-phase SCR control 24 V AC/DC control supply 3-phase SCR control
2-phase SCR control
Start/stop
Timed voltage ramp-up Timed voltage ramp-up Current limit start Adaptive Acceleration Control (AAC)
Adjustable start torque Adjustable initial torque Initial current ramp-up Current limit start
Selectable kick-start function Current ramp start
Dual parameter function
Kick-start
Jog
Timed voltage ramp-down Timed voltage ramp-down Timed voltage ramp-down Adaptive Deceleration Control (AAC)
TVR soft stop (Timed Voltage Ramp)
Coast to stop
DC brake function – three phase
Soft brake function
Jog
Protection
Motor overload As MCD 202 +
(adjustable trip class) Under current
Excess start time Current imbalance
Reverse phase rotation Starter overtemperature
Motor thermistor input Restart delay
Shorted SCR – no start Warning before trips
Supply fault – no start Adjustable phase imbalance sensitivity
Instantaneous overload – Programmable input trip
– Individual phase loss trips
– Individual shorted SCR trips
– Int. bypass relay overload
– Int. bypass relay fail
Fully adjustable protections
Network communication timeout
Heatsink overtemperature
Battery/clock failure
Supply frequency
External trip
Outputs
One output relay: Two output relays: Three programmable output relays:
Line contactor control Line contactor control Programmable analogue output
Run contactor or trip function Motor thermistor
Control
Universal two-wire control Two- or three-wire control Two- or three-wire control 8 language graphical display and keypad
Programmable via 3 rotary switches Programmable via 3 rotary switches Programmable via 8 rotary switches Quick menu and appplication menu
Reset push button Reset push button Buttons for start, stop, reset
and remote control
Optional: Optional: Inputs for two- or three-wire control
Modules for serial Modules for serial
communication communication Optional:
Remote operator kit Remote operator kit Modules for serial
PC software PC software communication
Remote operator kit
PC software
Other features
Extremely robust SCR design for Integral SCR bypass for Integral SCR bypass for Bypass up to 110 kW
unlimited number of starts per minimum physical size and heat minimum physical size and heat Configurable bus bars from 360 A and up
hour, LED indication, IP 20 dissipation during nominal operation dissipation during Operation timers
LED status indication nominal operation Jog – slow speed operation
IP 20 (7.5 – 55 kW @ 400 V) LED status indication Auto reset of fault situations
IP 00 (75 – 110 kW @ 400 V) IP 20 (7.5 – 55 kW @ 400 V) Emergency run
Protection kit available IP 00 (75 – 110 kW @ 400 V) 99 event log
Protection kit available Trip log
User programmable metering
and monitoring
Simulation before connecting
line voltage
7
7
What VLT® is all about
Danfoss VLT Drives is the world leader among dedicated drives providers
– and still gaining market share.