Sei sulla pagina 1di 1

M/S NAJ Enterprise

Test Report on Cement Concrete Mix Ratio Design

Location of Engineering Service Area for Slope Protection


Sample Model &
Sample Name Cement, River sand, Crushed stone Specification C25

Sample Description No Abnormalities


Test standards JGJ55-2011 GB/T50081-2002 GB/T50080-2002 GB50204-2002
Environment TEMP: 21 C, RH : 70% Date: 31.10.2020
mixture machine (Diesel Engine) 2.
Main instrument & devices
Electronic scales 3.DYE-2000 (E-15)
and ID

Place and position to be


Design strength(MPa) Construction method Remarks
Design Condition used

25 SA-SP Man power


Cement Brand Aramit Specification CEM-1;52.5N
Fine aggregate Origin Sylhet Specification Medium Sand
Coarse aggregate Origin Vietnam Specification 5~25mm
Additives / /
BCSIR-
Water Origin Drinking Water Ctg/39.02.1506.070.42.00
1.2020/
Recommend mix ratio(mass ratio), material & quantity table(kg/m3)

W/C Cement Fine aggregate Coarse aggregate / Water Additives

0.46 392.7 589.05 1178.1 / 180.642 /

Trial-mix records

Trial-mix Date 03.10.2020 Mixing ways Mixer Machine


Actual measured
50 Molding way Tamping
Slump(mm)

Theoretical Density of
2400 Actual Density (kg/m3) 2404
concrete (kg/m3)
Measured Measured values
values of Median value of copressive
Failure copressive of measured Failure strength fcu(Mpa) Measured values of
Age(d) Load strength compressive Age(d) Load copressive strength
F(KN) fcu(Mpa) strength F(KN) fcu(Mpa)
Compressive strength of the
fcu(mPa)
sample(MPa)

1007 44.8 894.3 50.5


7 945.8 42.0 41.57 28 985.75 55.6 53.57
852.06 37.9 967.37 54.6
Standards for judgment JTG E30-2005
Conclusion The results of the test items meet the requirements of the C25 concrete standard in JTG E30-2005

Potrebbero piacerti anche