Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Timer Period
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
Name Item Type (Readonly) Description
COND 2 Digital Input Master PBLed 08 [-F001] - Nivel 1 local
COND 3 Digital Input Master Remoto Nivel 1 - Line bay
VI 5 Digital Input Master Cmd CL Int by SEL411L - Etp 2 [IN6095]
VI 6 Digital Input Master Cmd OP Int by SEL411L - Etp 2 [IN6095]
VI 7 Digital Input Master Cmd CL Int by SEL311L - Etp 2 [IN6095]
VI 8 Digital Input Master Cmd OP Int by SEL311L - Etp 2 [IN6095]
COND 4 Digital Input Master Remoto Nivel 2 - Line bay
COND 5 Digital Input Master Local Nivel 2 - Remoto Nivel 1
VI 1 Digital Input Master Cmd CL Int by any - Etp 1 [IN6095]
VI 4 Digital Input Master Cmd OP Int by any - Etp 1 [IN6095]
VI 3 Digital Input Master Cmd CL Int by any - Etp 1 [IN6095]
VI 2 Digital Input Master Cmd OP Int by any - Etp 1 [IN6095]
VI 9 Digital Input Master Cmd CL Secc Bus by any - Etp 1 [2SB6088]
VI 10 Digital Input Master Cmd OP Secc Bus by any - Etp 1 [2SB6088]
VI 11 Digital Input Master Cmd CL Secc Bus by any - Etp 1 [2SB6088]
VI 12 Digital Input Master Cmd OP Secc Bus by any - Etp 1 [2SB6088]
VI 13 Digital Input Master Cmd CL Secc Bus by SEL411L - Etp 2 [2SB6088]
VI 14 Digital Input Master Cmd OP Secc Bus by SEL411L - Etp 2 [2SB6088]
VI 15 Digital Input Master Cmd CL Secc Bus by SEL311L - Etp 2 [2SB6088]
VI 16 Digital Input Master Cmd OP Secc Bus by SEL311L - Etp 2 [2SB6088]
VI 17 Digital Input Master Cmd CL Secc line by any - Etp 1 [2SL6046]
VI 18 Digital Input Master Cmd OP Secc line by any - Etp 1 [2SL6046]
VI 19 Digital Input Master Cmd CL Secc line by any - Etp 1 [2SL6046]
VI 20 Digital Input Master Cmd OP Secc line by any - Etp 1 [2SL6046]
VI 21 Digital Input Master Cmd CL Secc line by SEL411L - Etp 2 [2SL6046]
VI 22 Digital Input Master Cmd OP Secc line by SEL411L - Etp 2 [2SL6046]
VI 23 Digital Input Master Cmd CL Secc line by SEL311L - Etp 2 [2SL6046]
VI 24 Digital Input Master Cmd OP Secc line by SEL311L - Etp 2 [2SL6046]
Name Item Type (Readonly) Description
COND 1 Digital Input Slave Conexion Ok SEL 411L [C01CPM01F001]
Name Item Type (Readonly) Description
CMD 1 Digital Output Master Comando cierre interruptor [IN6095]
CMD 2 Digital Output Master Comando apertura interruptor [IN6095]
CMD 3 Digital Output Master Comando cierre seccionador [2SB6088]
CMD 4 Digital Output Master Comando apertura seccionador [2SB6088]
CMD 5 Digital Output Master Comando cierre seccionador [2SL6046]
CMD 6 Digital Output Master Comando apertura seccionador [2SL6046]
Variable NamExpression
COND_2 C01CPM01F001!RPBL_8
COND_3 COND_1? !COND_2 : TRUE
VI_5 VI_3 && COND_1
VI_6 VI_4 && COND_1
VI_7 VI_3 && !COND_1
VI_8 VI_4 && !COND_1
COND_4 AA1CMDL03!COND_0
COND_5 !COND_4? COND_3 : FALSE
VI_1 CMD_1
VI_4 COND_5? CMD_2 : FALSE
VI_3 COND_5? CMD_1 : FALSE
VI_2 CMD_2
VI_9 CMD_3
VI_10 CMD_4
VI_11 COND_5? CMD_3 : FALSE
VI_12 COND_5? CMD_4 : FALSE
VI_13 VI_11 && COND_1
VI_14 VI_12 && COND_1
VI_15 VI_11 && !COND_1
VI_16 VI_12 && !COND_1
VI_17 CMD_5
VI_18 CMD_6
VI_19 COND_5? CMD_5 : FALSE
VI_20 COND_5? CMD_6 : FALSE
VI_21 VI_19 && COND_1
VI_22 VI_20 && COND_1
VI_23 VI_19 && !COND_1
VI_24 VI_20 && !COND_1
Variable Name
CMD_1
CMD_2
CMD_3
CMD_4
CMD_5
CMD_6
Name Item Type (Readonly) Description
COND 2 Digital Input Master PBLed 08 [-F001] - Nivel 1 local
COND 3 Digital Input Master Remoto Nivel 1 - Line bay
VI 5 Digital Input Master Cmd CL Int by SEL411L - Etp 2 [IN6095]
VI 6 Digital Input Master Cmd OP Int by SEL411L - Etp 2 [IN6095]
VI 7 Digital Input Master Cmd CL Int by SEL311L - Etp 2 [IN6095]
VI 8 Digital Input Master Cmd OP Int by SEL311L - Etp 2 [IN6095]
COND 4 Digital Input Master Remoto Nivel 2 - Line bay
COND 5 Digital Input Master Remoto Nivel 2 - Remoto Nivel 1
VI 13 Digital Input Master Cmd CL Secc Bus by SEL411L - Etp 2 [2SB6088]
VI 14 Digital Input Master Cmd OP Secc Bus by SEL411L - Etp 2 [2SB6088]
VI 15 Digital Input Master Cmd CL Secc Bus by SEL311L - Etp 2 [2SB6088]
VI 16 Digital Input Master Cmd OP Secc Bus by SEL311L - Etp 2 [2SB6088]
VI 21 Digital Input Master Cmd CL Secc line by SEL411L - Etp 2 [2SL6046]
VI 22 Digital Input Master Cmd OP Secc line by SEL411L - Etp 2 [2SL6046]
VI 23 Digital Input Master Cmd CL Secc line by SEL311L - Etp 2 [2SL6046]
VI 24 Digital Input Master Cmd OP Secc line by SEL311L - Etp 2 [2SL6046]
VI 1 Digital Input Master Cmd CL Int by any - Etp 1 [IN6095]
VI 2 Digital Input Master Cmd OP Int by any - Etp 1 [IN6095]
VI 3 Digital Input Master Cmd CL Int by any - Etp 1 [IN6095]
VI 4 Digital Input Master Cmd OP Int by any - Etp 1 [IN6095]
VI 9 Digital Input Master Cmd CL Secc Bus by any - Etp 1 [2SB6088]
VI 10 Digital Input Master Cmd OP Secc Bus by any - Etp 1 [2SB6088]
VI 11 Digital Input Master Cmd CL Secc Bus by any - Etp 1 [2SB6088]
VI 12 Digital Input Master Cmd OP Secc Bus by any - Etp 1 [2SB6088]
VI 17 Digital Input Master Cmd CL Secc line by any - Etp 1 [2SL6046]
VI 18 Digital Input Master Cmd OP Secc line by any - Etp 1 [2SL6046]
VI 19 Digital Input Master Cmd CL Secc line by any - Etp 1 [2SL6046]
VI 20 Digital Input Master Cmd OP Secc line by any - Etp 1 [2SL6046]
Name Item Type (Readonly) Description
COND 1 Digital Input Slave Conexion Ok SEL 411L [C01CPM01F001]
Name Item Type (Readonly) Description
SSNETREM Digital Output Master Remoto Nivel 02
L3CMD 1 Digital Output Master Comando cierre interruptor [IN6095]
L3CMD 2 Digital Output Master Comando apertura interruptor [IN6095]
L3CMD 3 Digital Output Master Comando cierre seccionador [2SB6088]
L3CMD 4 Digital Output Master Comando apertura seccionador [2SB6088]
L3CMD 5 Digital Output Master Comando cierre seccionador [2SL6046]
L3CMD 6 Digital Output Master Comando apertura seccionador [2SL6046]
Variable Name Expression
COND_2 C01CPM01F001!RPBL_8
COND_3 COND_1? !COND_2 : TRUE
VI_5 VI_3 && COND_1
VI_6 VI_4 && COND_1
VI_7 VI_3 && !COND_1
VI_8 VI_4 && !COND_1
COND_4 COND_0
COND_5 COND_4? COND_3 : FALSE
VI_13 VI_11 && COND_1
VI_14 VI_12 && COND_1
VI_15 VI_11 && !COND_1
VI_16 VI_12 && !COND_1
VI_21 VI_19 && COND_1
VI_22 VI_20 && COND_1
VI_23 VI_19 && !COND_1
VI_24 VI_20 && !COND_1
VI_1 L3CMD_1
VI_2 L3CMD_2
VI_3 COND_5? L3CMD_1 : FALSE
VI_4 COND_5? L3CMD_2 : FALSE
VI_9 L3CMD_3
VI_10 L3CMD_4
VI_11 COND_5? L3CMD_3 : FALSE
VI_12 COND_5? L3CMD_4 : FALSE
VI_17 L3CMD_5
VI_18 L3CMD_6
VI_19 COND_5? L3CMD_5 : FALSE
VI_20 COND_5? L3CMD_6 : FALSE
Variable Name
COND_0
L3CMD_1
L3CMD_2
L3CMD_3
L3CMD_4
L3CMD_5
L3CMD_6
Name Item Type (Readonly) Description
S3DI 2 Digital Input Master Interruptor abierto [IN6095] | SEL311L
S3DI 1 Digital Input Master Interruptor cerrado [IN6095] | SEL311L
S3DI 4 Digital Input Master Seccionador abierto [2SB6088] | SEL311L
S3DI 3 Digital Input Master Seccionador cerrado [2SB6088] | SEL311L
S3DI 6 Digital Input Master Seccionador abierto [2SL6046] | SEL311L
S3DI 5 Digital Input Master Seccionador cerrado [2SL6046] | SEL311L
S3DI 8 Digital Input Master Cuchilla tierra abierto | SEL311L
S3DI 7 Digital Input Master Cuchilla tierra cerrado | SEL311L
S4DI 2 Digital Input Master Interruptor abierto [IN6095] | SEL411L
S4DI 1 Digital Input Master Interruptor cerrado [IN6095] | SEL411L
S4DI 3 Digital Input Master Seccionador cerrado [2SB6088] | SEL411L
S4DI 4 Digital Input Master Seccionador abierto [2SB6088] | SEL411L
S4DI 5 Digital Input Master Seccionador cerrado [2SL6046] | SEL411L
S4DI 6 Digital Input Master Seccionador abierto [2SL6046] | SEL411L
S4DI 7 Digital Input Master Cuchilla a tierra cerrado | SEL411L
S4DI 8 Digital Input Master Cuchilla a tierra abierto | SEL411L
HMI POS 1 Digital Input Master Interruptor cerrado [IN6095]
HMI POS 2 Digital Input Master Interruptor abierto [IN6095]
HMI POS 3 Digital Input Master Seccionador cerrado [2SB6088]
HMI POS 4 Digital Input Master Seccionador abierto [2SB6088]
HMI POS 5 Digital Input Master Seccionador cerrado [2SL6046]
HMI POS 6 Digital Input Master Seccionador abierto [2SL6046]
HMI POS 7 Digital Input Master Cuchilla tierra cerrado
HMI POS 8 Digital Input Master Cuchilla tierra abierto
Name Item Type (Readonly) Description
COND 1 Digital Input Slave Conexion Ok SEL 411L [C01CPM01F001]
Variable Name Expression
S3DI_2 C01CPM01F002!RDI_2
S3DI_1 !S3DI_2
S3DI_4 C01CPM01F002!RDI_3
S3DI_3 !S3DI_4
S3DI_6 C01CPM01F002!RDI_5
S3DI_5 !S3DI_6
S3DI_8 C01CPM01F002!RDI_6
S3DI_7 !S3DI_8
S4DI_2 C01CPM01F001!RPOS_2
S4DI_1 C01CPM01F001!RPOS_1
S4DI_3 C01CPM01F001!RPOS_3
S4DI_4 C01CPM01F001!RPOS_4
S4DI_5 C01CPM01F001!RPOS_5
S4DI_6 C01CPM01F001!RPOS_6
S4DI_7 C01CPM01F001!RPOS_7
S4DI_8 C01CPM01F001!RPOS_8
HMIPOS_1 COND_1? S3DI_1 : S4DI_1
HMIPOS_2 COND_1? S3DI_2 : S4DI_2
HMIPOS_3 COND_1? S3DI_3 : S4DI_3
HMIPOS_4 COND_1? S3DI_4 : S4DI_4
HMIPOS_5 COND_1? S3DI_5 : S4DI_5
HMIPOS_6 COND_1? S3DI_6 : S4DI_6
HMIPOS_7 COND_1? S3DI_7 : S4DI_7
HMIPOS_8 COND_1? S3DI_8 : S4DI_8