1. Description of ANN screen


1.1. Initial screen of annunciator
Initial screen : When the main power turn on, LCD display will show as below.
C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16

R1 A C D = 0 4 [ 0 1 ] 0 0 %
R2 E 0 0 0 - 0 0 1 0 0 0 0 S
R3 1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
R4 K :

1) Row 1 : Operation mode, present floor, load weight and speed of elevator.
1 ACD=27(Column1~ 6) : Operation Code( ex: 27*Auto operation, 4*Maintenance
operation...) ※ Refer to the MODE Description
② 01FL(Column 8 ~11) : Present floor
③ 00%(Column 13 ~ 16) : On stop, present load weight (%) of the elevator.
2) Row 2 : When an error occurs, it shows the trouble code of the top level error,
condition of the operation, output of main signal and direction of elevator.
① E000(Column 2 ~ 4) : Trouble code of top level error.(TCD No. 1 ~ 255)
ex)
031 DC LINK Overvoltage 116 POSI ON error(LDU)

052 INV reverse running detection 172 SD1U input error


084 R5SC RELAY ON error 200 CNET LON comm. Error

② 00(Column 6 ~ 7) : Operation condition of the top level error


ex)
01 R5SC Cut 10 FAST RUN Cut
02 R5SC Cut possible 20 SAFETY Drive operation possible

04 C1ST Cut 40 REST operation possible

08 C1ST Cut possible 80 HALL CALL Cut possible


③ 100100(Column 9 ~ 14) : Displays output of main signals.
- "1" : Means that switches, relay and contactors, etc. are operating.
- "0" : Means that switches, relay and contactors, etc. are not operating.
- Each column means as follows;
C9 R5SC C10 C1ST C11 C1BR C12 C1BS
C13 DOOR OPEN command C14 DOOR CLOSE command
Test & Commissioning Rev. No. 0

for SI210 Controller Doc. No. 695-108

FOD Page 2/21


Overseas Support Team
Annunciator Date MAR. 2003

④ S(C16) : Displays the present direction of elevator.


- "S" : STOP "U" : UP "D" : DOWN

3) Row 3 : Displays input condition of main signal such as switches, relays and
contactor, etc.
C1 R5SC C5 LDC C9 C1ST C13 CDS
C2 48V C6 LDCX C10 C1BR C14 DCLS
C3 UL C7 SDS1D C11 SUPPRESS C15 DOLS
C4 DL C8 SDS1U C12 LDS C16 SES

- "1" : Means that switches, relay and contactors, etc. are operating.
- "0" : Means that switches, relay and contactors, etc. are not operating.

1.2 ACD MODE


Mode Description Mode Description Mode Description
00 Stop 01 ALP operation 02 Earthquake control door open

03 Failure 04 MAINT operation 05 Earthquake control finished

06 Earthquake control 07 Earthquake ctrl slow opr 08 Bottom F slow opr (Spec.ROM F height error)

09 F/H measurement prep. 0A F height meas. Opr 0B Bottom F slow opr (C.RAM F height error)

0C Unused 0D Unused 0E 2
nd
fire opr

0F 1st fire operation 10 Arrival opr finished 11 All Fs opr after earthquake ctrl

12 Emergency return opr. 13 Fireman opr 14 Fireman return opr

15 Rescue arrival opr. 16 Rescue opr 17 Rescue arrival opr finished

18 Rescue return opr. 19 Fire operation finished 1A Fire opr

1B TM temp. detecting opr finished 1C TM temp. detecting opr 1D Unused

1E EGN driven opr finished 1F EGN driven opr 20 CP temp.detecting opr finished

21 CP temp. detecting opr. 22 REST 23 Standby opr finished

24 ATT operation 25 Semi-auto opr 26 Backup opr

27 Auto-operation 28 Aircon. drain oper.


Test & Commissioning Rev. No. 0

for SI210 Controller Doc. No. 695-108

FOD Page 3/21


Overseas Support Team
Annunciator Date MAR. 2003

2. ANN Function Mode

Annunciator function mode


MAIN MODE SUB MODE Resetting
Classification
MAIN MODE KEY Input SUB MODE KEY Input KEY Input
Operation Floor height measurement Op. ★ A12E START 3 FFFF
related mode Input lowest floor call ★ A13E
Input middle floor call ★ A14E
Input highest floor call ★ A15E
Input lowest floor call (Hold) ★ A16E FFFF
Input middle floor call (Hold) ★ A17E
Input highest floor call (Hold) ★ A18E
Input random floor call CxxE xx -> Floor
Memory DATA READ & WRITE ★ A21E Address INC 0 FFFF
related mode ★ A22E Address DEC 8
Address Input xxxxE
Address Re-input BBB
PROTECTION release AAE
Data Input xxE
TRACE DATA READ A23E Item INC 0 FFFF
(TRACE when error occurs Item DEC 8
5000h ~ ) Block INC 1
Block DEC 9
TRACE DATA READ A24E Item INC 0 FFFF
(TRACE when reset occurs Item DEC 8
4400h ~ ) Block INC 1
Block DEC 9
Statistics Data read & A25E Item INC 0 FFFF
Deletion Item DEC 8
DATA Deletion CCCC
Statistics Data deletion A26E Deletion check E FFFF
Reset count without power failure A27E FFFF
Emergency stop TRACE A28E Item INC 0 FFFF
Data read Item DEC 8
Deletion all CCCC
Spec SPEC DATA READ & WRITE ★ A31E Address INC 0 FFFF
related mode ★ A32E Address DEC 8
Address Input xxxxE
Address Re-input BBB
PROTECTION release AAE
Data Input xxE
Test & Commissioning Rev. No. 0

for SI210 Controller Doc. No. 695-108

FOD Page 4/21


Overseas Support Team
Annunciator Date MAR. 2003

※ ★ mark is same function as DI1 model.

Annunciator function mode


MAIN MODE SUB MODE Resetting
Classification
MAIN MODE KEY Input SUB MODE KEY Input KEY Input
Error TCD DISPLAY ★ A41E TABLE INC 0 FFFF
related mode TABLE DEC 8
ERROR LOG DISPLAY ★ A42E TABLE INC 0
TABLE DEC 8
First error 1 FFFF
Last error 9
Display mode change C
(Time->Trace)
ERROR LOG CLEAR ★ A43E
TCD CLEAR ★ A44E
DSP mode DSP READ ★ A51E Address INC 0 FFFF
Address DEC 8
Address Input xxxxE
Address Re-input BBB
DSP SPEC WRITE ★ A52E
Parameter NO LOAD POINT SET ★ A61E FFFF
related mode FULL LOAD POINT SET ★ A62E Load Input xxxE FFFF
HALF LOAD POINT SET A65E Load Input xxxE FFFF
RTC SET ★ A69E Date/Time mode change C FFFF
Data Input xxE
State check OS ROM version check A01E FFFF
mode DSP ROM version check A02E FFFF
PCB Protection check A03E FFFF
Multi-step deceleration value check A06E FFFF
Door condition check A71E FFFF
Car Load display A86E FFFF
Device Test Hall Check Mode A82E FFFF
mode Car Check Mode A83E FFFF
POSI measurement mode ★ A85E UP operarion UP Switch FFFF
DN operation DN Switch
110% Function test mode A87E Testing Load Input (%) xxE FFFF
SDS Test mode A89E SDS Test (UP) 3 FFFF
SDS Test (DN) 7

※ ★ mark is same function as DI1 model


Test & Commissioning Rev. No. 0

for SI210 Controller Doc. No. 695-108

FOD Page 5/21


Overseas Support Team
Annunciator Date MAR. 2003
Test & Commissioning Rev. No. 0

for SI210 Controller Doc. No. 695-108

FOD Page 6/21


Overseas Support Team
Annunciator Date MAR. 2003

Annunciator function mode


MAIN MODE SUB MODE Resetting
Classification
MAIN MODE KEY Input SUB MODE KEY Input KEY Input
Other mode LCD INITIALIZE " 00000 " FFFF
DCO On Mode A84E FFFF
110% Cut mode ★ A88E
CRT Data reset A90E
ESMI Control(Maint) A91E A93E
ESMI Control(Inspection) A92E A93E
ESMI Control Reset A93E

※ ★ mark is same function as DI1 model