Sei sulla pagina 1di 22

SPEAKER TEST PROCEDURE

A PROCEDURE, EQUIPMENT REQUIRED AND A TEST SET-UP ARE GIVEN FOR EACH TEST
REQUIRED.

BEAR IN MIND THAT SOME SET-UPS ARE REPETITIVE AND SO THE SET-UP AND
PROCEDURE WILL BE SOMEWHAT SIMILAR.

EQUIPMENT REQUIRED FOR ALL TESTS A THROUGH D:

(1) DVM (Digital Volt Meter)


(2) OSCILLATOR ADJUSTABLE
(3) NEUTRIK
(4) POWER AMPLIFIER AUDIO/ WITH PRE AMP IF REQUIRED
(5) FREQUENCY COUNTER
(6) MICROPHONE AND PRE AMP /POWER SUPPLY
(7) ALL INTERCONNECTING WIRE
(8) IMPEDANCE MEASUREMENT CIRCUIT (APOGEE)
(9) MARKING STICK OR SCALE
(10) OSCILLOSCOPE

THE SEQUENCE OF TESTS IS LISTED BELOW AND THE PROCEDURES WILL BE PREFIXED
UNDER THE LETTER GIVEN.

EQUIPMENT SET-UP FOR TEST:


A - WOOFER TUNING
B - RESONANCE
C - MRT/WOOFER PHASE TEST
D - ONE METER RESPONSE
E - IMPEDANCE OF SYSTEM

(SOME SEQUENCE VARIATION CAN OCCUR. THIS IS ONLY RECOMMENDED SEQUENCE.)


TEST A - WOOFER TUNING
FOR TEST A, WOOFER TUNING SET UP THE FOLLOWING TEST EQUIPMENT

FROM TIDE LIST ON THE FRONT COVER:

(1)DVM
(3)NEUTRIK
(4)POWER AND (PRE AMP)
(5)FREQUENCY COUNTER
(6)MICROPHONE/POWER SUPPLY
(7)CONNECTING WIRE
(9)MARKING STICK

BEFORE WE PROCEED WITH THE TEST, SOME PRELIMINARY SET-UP IS REQUIRED.

MARK SPEAKER FOR MEASUREMENT POINTS (FIG. I)

SET UP MICROPHONE CLOSE TO SPEAKER (FIG. 2)

EQUIPMENT SET-UP THEN WE CAN GO ON AND TUNE SPEAKER


MICROPH0NE PLACEMENT
MICROPHONE SHOULD BE SQUARE AND PARALLEL TO THE FACE OF THE SPEAKER.

MICROPHONE SHOULD BE APPROXIMATELY 1" FROM FACE OF SPEAKER.

MICROPHONE SHOULD BE CONNECTED TO THE B AND K PRE AMP AND POWER SUPPLY.

MAKE SURE THAT IT IS "ON" AND IN THE FIRST CLICK POSITION.

OBSERVE THE BATTERY INDICATOR AND MAKE SURE THAT NEEDLE IS

IN THE GREEN PORTION OF THE SCALE - IF NOT, CHANGE BATTERIES.

THE OUTPUT OF MICROPHONE PRE AMP/POWER SUPPLY SHOULD BE CONNECTED TO


THE NEUTRIK INPUT. (SEE FIG. 3.2)

SET UP NEUTRIK AS FOLLOWS:

PAPER SPEED - 3 mm/s FOR RESPONSE CURVES


PLOT MODE/SINGLE
INPUT IMPEDANCE/GOO
INPUT/UNBALANCED
INPUT RANGE/-20db OR -40db
VERNIER/CALIBRATE
0 db REFERENCE/DBM (0.775V)
HP FILTER/--- (FLAT)
DISPLAY SCALE/50db
WRITING SPEED -- 20 mm/s FOR RESPONSE CURVES
OUTPUT RANGE/ANYWHERE FROM - 20db TO -l0db DEPENDING ON WHAT IS TO BE
MEASURED: MOST LIKELY SETTING IS -l0db.
VERNIER/WHATEVER ADJUSTMENT FOR LEVEL DESIRED AT

SPEAKER INPUT TERMINALS.


0 db Ref/DBM (0.775V)
MUTE/ON OR OFF (ON SOUND OUT, OFF NO SOUND)
START FREQUENCY/WHATEVER YOU WANT FOR FREQUENCY OUTPUT TO START. AT, BUT
SHOULD BE 20Hz FOR TEST.
SWEEP FUNCTION/CONTINUOUS WARBLE 1/3 Oct.

SET UP DVM AS FOLLOWS:

AC VOLTS
VOLTS
20 VOLT RANGE
RELATIVE OFF
CONNECT NEUTRIK OUTPUT TO POWER AMPLIFIER INPUT, CONNECT MICROPHONE OUTPUT
TO NEUTRIK INPUT. CONNECT POWER AMP OUTPUT TO WOOFER INPUT ON SPEAKER.
(FIG,3 AND 3.2)

FREQUENCY CAN BE MEASURED AT THE OUTPUT OF THE NEUTRIK AND THE VOLTAGE CAN
BE MEASURED AT THE OUTPUT OF THE AMPLIFIER OR THE INPUT TO THE SPEAKER
WHICH EVER IS EASIER TO DO.

NOTE: CONNECT POWER AMP OUTPUT TO WOOFER TERMINALS ON SPEAKER.

FIGURE No.3
TEST A EQUIPMENT CONFIGURATION

STARTING OUT WITH THE NEUTRIK IN THE LOWEST FREQUENCY OUTPUT (20 Hz) AND
THE MICROPHONE POSITIONED AT THE BOTTOMMOST MARK, APPLY AN AUDIO SIGNAL TO
THE SPEAKER. MEASURE WITH THE DVM AN OUTPUT LEVEL OF 2.3 VOLTS A.C. AT THE
TERMINALS OF THE SPEAKER. THIS IS NOT A CRITICAL VOLTAGE; IT'S JUST A LEVEL
THAT WILL GIVE A WORKABLE AMOUNT OF SOUND OUTPUT FROM THE SPEAKER.

ON THE STRAIGHT SIDE OF THE SPEAKER THERE ARE A NUMBER OF HEX HEAD SCREWS
SET INTO HOLES (THIS IS THE EDGE OF THE SPEAKER). THESE ARE THE ONES THAT
ARE TIGHTENED OR LOOSENED TO MAKE THE RESPONSE THAT IS WANTED.

THIS BASIC PROCEDURE IS REPEATED FOR EACH MARK; TOP, MIDDLE AND BOTTOM.

IN TUNING THE SPEAKER, WE ARE AIMING AT HAVING THE BOTTOM PEAK IN AMPLITUDE
AT THE LOWEST FREQUENCY, THE MIDDLE THE NEXT HIGHEST FREQUENCY, AND THE TOP
AT THE HIGHEST FREQUENCY, THE BOTTOM SHOULD BE 33Hz TO 37Hz. THE MIDDLE
SHOULD BE 38Hz TO 42Hz AND THE TOP SHOULD BE 43Hz TO 47Hz.

TO PERFORM THE TUNING PROCEDURE WITH MICROPHONE IN THE POSITION PREVIOUSLY


STATED, PUSH THE START. ALLOW THE NEUTRIK TO GO TO ABOUT 100Hz OR SO.
YOU CAN THEN EITHER PRESS FAST FORWARD OR STOP. YOU WILL SEE THE AMPLITUDE
TRACE FROM A LOW AMPLITUDE TO A PEAK AND THEN FALL OFF AGAIN TO A LOWER
AMPLITUDE.

THE POINT WHERE THE AMPLITUDE DISPLAY PEAKS IS THE RESONANCE FREQUENCY.
THIS IS THE POINT YOU ADJUST WITH THE SCREWS ON THE SPEAKER TO CHANGE IT'S
FREQUENCY. THE BOTTOM SCREWS ARE FOR THE LOWER PART OF THE SPEAKER AND THE
MIDDLE SCREWS FOR THE MIDDLE PORTION OF THE SPEAKER AND SO ON. CARE MUST BE
TAKEN NOT TO TIGHTEN THE TENSIONING SCREWS TOO MUCH. BY NO MEANS SHOULD YOU
TURN IN THE SCREWS SO MUCH THAT YOU COMPRESS THE SPRING COMPLETELY.
RESONANCE TEST - TEST "B"
EQUIPMENT REQUIRED
(1)DVM
(3)NEUTRIK
(4)POWER AMP (PRE AMP)
(5)FREQUENCY COUNTER
(6)MICROPHONE/POWER SUPPLY
(7)CONNECTING WIRE
(10)OSCILLOSCOPE

BEFORE THIS TEST CAN BE PERFORMED, THE WOOFER MUST BE TUNED AND AN MRT
MATED TO IT.

SPEAKER SHOULD BE IN THE GENERAL LOCATION OF THE NORMAL, OPERATING POSITION


IN THE ROOM.

MICROPHONE SHOULD BE PLACED CLOSE TO THE SPEAKER AS IN TEST "A". SETTING UP


THE MICROPHONE CLOSE TO SPEAKER, SAME PRECAUTIONS TO APPLY.

THE MICROPHONE SHOULD BE POSITIONED IN THE CENTER OF THE WOOFER.

INTER CONNECT EQUIPMENT

SET UP OF NEUTRIK:

MAINFRAME:
PAPER SPEED/0.3mm/S, PLOT MODE/SINGLE
INPUT MODILE:
INPUT IMPEDANCE/600Ω, INPUT/UNBALANCED
INPUT RANGE/-20db or -10db (USE ENOUGH GAIN TO PLACE DISPLAY ON GRAPH
PAPER)
VERNIER/CALIBRATE
0db REFERENCE/DBM (0.775v)
HP FILTER/ - (FLAT)
DISPLAY SCALE/50db
WRITING SPEED/20mm/S
OUTPUT MODULE:
OUTPUT RANGE/ -10db to 0db (DEPENDS ON THE GAIN OF
AMP/PRE AMP)
VERNIER/POSITION DEPENDS ON GAIN OF PRE AMP/AMP AND VOLTAGE DESIRED AT
OUTPUT OF AMP.
START FREQUENCY/300Hz
SWEEP FUNCTION/CONTINOUS SINE NO WARBLE
SET UP OF FREQUENCY COUNTER

SELECT Hz
FILTER IN
POWER ON

SET UP OF OSCILLOSCOPE:

SET DISPLAY SO THAT YOU JUST ABOUT FILL THE SCREEN ON THE LARGEST RECEIVED
SIGNAL FROM THE MICROPHONE AND THAT YOU CAN OBSERVE 4 OR 5 COMPLETE CYCLES
OR THE WAVE SHAPES.

BE CERTAIN THAT NEUTRIK IS ON MUTE. (TURN ON NEUTRIK, POWER AMP,


OSCILLOSCOPE MICROPHONE (ONE CLICK FROM OFF). WHEN YOU TURN NEUTRIK OUTPUT
ON (MUTE OFF) ADJUST VERNIER OUT AND/OR OUTPUT RANGE TO PRODUCE 2.3 VOLTS
A.C. AT SPEAKER TERMINALS OR AMPLIFIER OUTPUT.

NOTE: FOLLOW SAME SPEAKER WIRING PROCEDURES THAT ARE SET OUT IN THE "C"
TEST (RESPONSE 1 METER).

YOU SHOULD HAVE SOUND COMING FROM THE SPEAKER AND 2.3 VOLTS REGISTERING ON
THE DVM.

YOU CAN NOW START NEUTRIK (TRACE SHOULD START AT 300 Hz)LET THE NEUTRIK
RECORD OUTPUT UNTIL YOU HAVE PASSED 500 Hz DISPLAY ON FREQUENCY COUNTER.
YOU CAN NOW STOP OR FAST FORWARD THE PAPER OUT OF THE MACHINE. YOUWILL HAVE
TO LOOK AT THE TRACING PRODUCED AND THE: OSCILLOSCOPE DURING THE TIME THAT
THE NEUTRIK IS GLIDING THROUGH THE FREQUENCY RANGE. WHAT YOU ARE LOOKING
FOR IS A DIP OR PEAK IN THE TRACE PRODUCED BY THE NEUTRIK AND/OR A
DISTORTION OF THE WAVE SHAPE DISPLAYED ON THE OSCILLOSCOPE.
DURING THIS TIME YOU SHOULD ALSO HAVE AN "EAR" LISTENING TO THE SOUND
PRODUCED. IT MAY SOUND CLEAN (NO DISTORTION) "RASPY" OR HAVE A "WHA WHA"
SOUND TO IT. YOU SHOULD TRY TO NOTE WHAT FREQUENCY THESE LAST TWO SOUNDS
OCCUR AT SO YOU CAN "GO BACK" TO IT AND MAKE FURTHER DETERMINATIONS AS TO
THE SERIOUSNESS OF IT.
YOU MAY NOT HEAR ANYTHING DURING THE FREQUENCY SWEEP BUT YOU MAY SEE A
DISTORTION ON THE OSCILLOSCOPE. THIS FREQUENCY SHOULD BE NOTED FOR THE SAME
REASONS AS ABOVE. THIRDLY, YOU WILL OBSERVE ON THE GRAPH PRODUCED BY THE
NEUTRIK SOME LEVELS OF OUTPUT WHICH ARE MARKEDLY HIGHER OR LOWER THAN THE
AVERAGE OF THE REST OF THE TRACE. ALL OF THESE CONDITIONS ARE POSSIBLE
RESONANCE PROBLEMS. THE CHANCES ARE THAT MOST OF THE INDICATORS NOTED WILL
BE THE SAME FREQUENCY OR VERY CLOSE TO EITHER. THE BEST ONES TO START AT
ARE THE ONES ON THE NEUTRIK TRACE. THE INDICATIONS WHICH GO BELOW THE
AVERAGE ARE THE ONES MOST LIKELY TO CAUSE PROBLEMS.

WITH THE NEUTRIK IN THE "REST" MODE YOU CAN CONTROL THE OUTPUT FREQUENCY BY
THE FREQUENCY START KNOB. TURN THE KNOB UNTIL THE FREQUENCY METER READS THE
SAME AS THE "NOTED" FREQUENCY. AT THIS TIME YOU SHOULD OBSERVE THE
OSCILLOSCOPE TRACE LOOK AT WAVE SHAPE AND CHECK TO SEE DISTORTION. YOU MAY
HAVE TO "HUNT" WITH THE FREQUENCY KNOB TO SEE EFFECTS ON THE OSCILLOSCOPE.
IF YOU SEE ANY DISTORTION OR AN ABRUPT CHANGE IN LEVEL. SEE IF YOU CAN
INDUCE A "WHA WHA" FROM THE SPEAKER BY INCREASING THE OUTPUT LEVEL OF THE
AMPLIFIER (TURN UP THE VOLUME). DO NOT GO ABOVE 20 VOLTS INPUT TO THE
SPEAKER. IF IT DOES GO INTO THE "WHA WHA" MODE DETERMINE THE LOWEST VOLTAGE
INPUT THAT MAKES IT "GO". YOU MAY HAVE TO "HUNT" AROUND WITH THE FREQUENCY
KNOB SOME MINOR AMOUNT TO GET THE ABSOLUTE LOWEST VOLTAGE. A SPEAKER MAY
HAVE MORE THAN ONE RESONATE POINT AND A DIFFERENT VOLTAGE FREQUENCY ET
CETERA.
A SEPARATION OF 1 OR 2 Hz IS PROBABLY THE SAME POINT. ANYTHING MORE THAN A
FEW Hz SEPARATION IS PROBABLY A NEW POINT.

NOTE: NOT ALL INDICATIONS WILL RESULT IN A "WHA WHA" SO USE DISCRETION WHEN
INVESTIGATING THESE POINTS. DON’T SPEND A LOT OF TIME ON EACH POINT.
THE DEPTH OF TRACE ANOMALY OR SEVERITY OF DISTORTION IS DIRECTLY RELATED TO
THE PROBABILITY OF FINDING A POINT AT WHICH THE SPEAKER "BREAKS UP”

RECORD THE LEVEL (VOLTS) AND THE FREQUENCY AT WHICH YOU COULD MAKE IT
"BREAK UP" ON THE NEUTRIK GRAPH PAPER. A PASSABLE OR ACCEPTABLE LOWEST
VOLTAGE IS 11 VOLTS.
TEST "C" - MRT/WOOFER PHASE TEST
FOR THIS TEST YOU WILL NEED:
(1)DVM
(3)NEUTRIK
(4)POWER AMPLIFIER/WITH PRE AMP IF REQUIRED
(6)MICROPHONE AND PRE AMP/POWER SUPPLY
(7)ALL INTERCONNECTING WIRE
(10) OSCILLOSCOPE

BEFORE THIS TEST CAN BE PERFORMED THE WOOFER MUST BE TUNED AND AN MRT MATED
TO IT.

SPEAKER PLACEMENT IS NOT CRITICAL.

MICROPHONE SHOULD BE CLOSE TO SPEAKER AS IN TEST "A" AND SAME PRECAUTIONS


APPLY.

MICROPHONE SHOULD BE IN CENTER OF WOOFER AND CENTER OF MRT FOR TEST.


EQUIPMENT INTERCONNECTION
AS SHOWN BELOW

SET UP OF NEUTRIK:

NEUTRIK IS IN RESET MODE FOR THIS TEST AND MOST CONTROLS ARE NOT

MAIN FRAME NA
INPUT MODULE ETA,
OUTPUT MODULE

OUTPUT RANGE -10db TO 0db (DEPENDS ON GAIN OF AMPLIFIER/PRE AMP)

VERNIER: POSITION DEPENDS ON GAIN OF PRE AMP/AMPLIFIER

START FREQUENCY: FREQUENCY IS THE ONE MARKED ON DATA LOG 100Hz 1.5KHz
SWEEP FUNCTION: CONTINUOUS SINE, NO WARBLE

OSCILLOSCOPE:

ADJUST GAIN OF A AND B INPUTS SO THAT EACH FILL APPROXIMATELY 1/2 THE
SCREEN.
ADJUST BASE SO THAT YOU CAN OBSERVE ABOUT 5 CYCLES OF DISPLAYED WAVE SHAPE.

DMM:
MEASURE AC
VOLTS
RANGE 20
RELATIVE OFF
SET UP MICROPHONE SO THAT IT IS IN THE CENTER OF THE WOOFER VERTICALLY AND
HORIZONTALLY.

MAKE CERTAIN THAT OUTPUT OF NEUTRIK WILL NOT PRODUCE AN OVERLY BIG OUTPUT
AT POWER AMP. BEST TO START WITH LEVEL AT VERY LOW LEVELS.

TURN NEUTRIK MUTE ON. TURN ON NEUTRIK, POWER AMP, DMM, OSCILLOSCOPE AND
MICROPHONE. WHEN MICROPHONE IS TURNED ON, MAKE CERTAIN THAT IT IS ONE CLICK
FROM OFF POSITION AND THAT BATTERY INDICATION IS TN THE "GREEN" . CHANGE
BATTERIES IF READING IS LOW.

TURN OFF MUTE ON NEUTRIK AND ROUGHLY ADJUST OUTPUT OF NEUTRIK TO PRODUCE
2.3 VOLTS AT SPEAKER TERMINALS.

OBSERVE ON THE OSCILLOSCOPE THAT THE CHANNEL "A" IS 180° OUT OF PHASE WITH
CHANNEL "B" AT 100 HZ.

MOVE THE NEUTRIK OUTPUT FREQUENCY TO THE NEXT FREQUENCY, 1.5 KHZ OBSERVE
THAT THE CHANNEL "A" IS IN PHASE WITH CHANNEL "B" (YOU MIGHT HAVE TO
INCREASE GAIN OF CHANNEL "B" TO OBSERVE THIS). MOVE MICROPHONE TO CENTER OF
MRT. (MICROPHONE SHOULD BE REASONABLY CLOSE TO RIBBON). OBSERVE THAT
CHANNEL "A" IS IN PHASE WITH CHANNEL "B".

WITH MICROPHONE STILL AT MRT, CHECK OUTPUT PHASE AT 10KHz; SHOULD BE


ROUGHLY IN PHASE.

RECORD SERIAL NUMBER OF SPEAKER ON DATA LOG AND CHECK APPROPRIATE BOX ON
LOG.
1 METER RESPONSE - TEST "D"
EQUIPMENT REQUIRED:
(4)AUDIO POWER AMP (PRE AMP)
(6)B AND K MICROPHONE AND POWER SUPPLY
(3)NEUTRIK
(1)DVM
(7)INTERCONNECTING CABLE

THIS TEST IS TO BE PERFORMED ONLY AFTER THE WOOFER HAS BEEN TUNED AND THE
MRT HAS BEEN MATED TO IT. VERIFY THAT ALL INTERNAL SPEAKER WIRING IS
CORRECT AND ALL CONNECTIONS TIGHT.

FIRST, POSITION SPEAKER CORRECTLY IN ROOM. RIGHT ON RIGHT SIDE, POSITION


TILT BACK ETC. (USE POSITION TAPE ON FLOOR).

CONNECT OUTPUT OF AUDIO POWER AMP TO TERMINALS/TERMINAL OF SPEAKER. THERE


ARE TWO WAYS TO DO THIS. BI WIRE AND MONO WIRE. IF YOU ARE GOING TO MONO
WIRE THE SPEAKER, YOU WILL HAVE TO INSTALL SHORTING BARS ACROSS SPEAKER
TERMINALS. RED TO RED AND BLACK TO BLACK.

SEE DIAGRAM
IF YOU ARE GOING TO "BI WIRE" THE SPEAKER YOU WILL NOT NEED THE SHORTING
BARS AT ALL BUT YOU WILL NEED ANOTHER SET OF CONNECTING WIRES FROM THE
POWER AMP

AND YOU WILL HAVE TO CONNECT IT THIS WAY:

APPLY OUTPUT OF NEUTRIK TO PRE AMP IF REQUIRED AND THE OUTPUT OF PRE AMP TO
INPUT OF POWER AMP. THEN CONNECT OUTPUT OF POWER AMP AS DISCUSSED ABOVE, TO
THE SPEAKER.

SET UP MICROPHONE SO THAT IT IS 1 METER AWAY (39"). MICROPHONE SHOULD BE


SET SO THAT IT IS APPROXIMATELY MID HEIGHT AND THAT IT IS POINTING AT THE
WOOD IN THE JUNCTION OF THE MID RANGE AND THE WOOFER.
IMPEDANCE TEST – TEST "E"
MRT AND WOOFER

EQUIPMENT REQUIRED:

(2)OSCILLATOR ADJUSTABLE OUTPUT FREQUENCY AND AMPLITUDE


(5)FREQUENCY COUNTER
(1)DMM(DIGITAL MULTI METER)
(8)APOGEE IMPEDANCE NETWORK
(7)TEST LEADS

THIS TEST IS ONLY TO BE PERFORMED AFTER WOOFER HAS BEEN TUNED

AND MRT MATED TO WOOFER. ALL CONNECTIONS MADE AND VERIFIED AS TO


CORRECTNESS AND THE QUALITY (TIGHTNESS).

CONNECT APOGEE IMPEDANCE NETWORK BETWEEN TESTING EQUIPMENT AS SHOWN IN


DIAGRAM BELOW.

SPEAKER PLACEMENT IN THE ROOM IS NOT CRITICAL.


IMPEDANCE CONTINUED

SET DMM UP SELECT AC INPUT AND YOU ARE GOING TO MEASURE VOLTS. YOU WANT TO
SELECT THE 200mv RANGE. MAKE CERTAIN THE RELATIVE SWITCH IS OFF(OUT).

TAKE WIRE FROM NETWORK WHICH IS LABELED DMM AND PUT IT INTO THE "COMMON"
"V/KO/S" BANANA JACK ON DMM MAKING CERTAIN THAT THE SIDE OF THE PLUG WITH
BUMP ON IT IS IN THE "COMMON" HOLE ON DMM.

OSCILLATOR: SELECT SINE WAVE OUTPUT (PUSH BUTTON)


FREQUENCY OUTPUT IS DETERMINED BY THE MULTIPLIER PUSH BUTTONS AND THE
FREQUENCY ADJUST KNOB. OUTPUT SHOULD BE CONNECTED TO NETWORK LEAD MARKED
OSC.

FREQUENCY COUNTER: TURN THE FILTER ON (BUTTON PUSHED IN) IT'S A BLACK
BUTTON AND YOU ARE GOING TO MEASURE HZ (BUTTON PUSHED IN) IT'S A GREY
BUTTON. THE INPUT TO COUNTER. SHOULD BE TAKEN DIRECTLY FROM THE OSCILLATOR
OUTPUT. THIS CAN BE DONE WITH A "TEE" ADAPTOR.
ONE LEAD FROM THE NETWORK IS NOW "LEFT OVER". THIS SHOULD BE CONNECTED TO
THE CALIBRATION RESISTOR.

TURN ON OSCILLATOR FREQUENCY COUNTER AND DMM. ADJUST LEVEL OUTPUT OF


OSCILLATOR TO GIVE A READING ON THE FREQUENCY COUNTER. NOW ADJUST FREQUENCY
OUTPUT BY MEANS OF MULTIPLIER BUTTONS AND FREQUENCY ADJUST KNOB TO THE
DESIRED FREQUENCY (SEE DATA RECORDING SHEET). NOW ADJUST THE AMPLITUDE OF
OSCILLATOR TO GIVE A READING ON THE DMM OF 4.0.

REMOVE THE CALIBRATION RESISTOR FROM THE NETWORK AND PLACE THE END OF THE
NETWORK INTO THE APPROPRIATE TERMINAL OF THE SPEAKER BEING TESTED AND READ
THE VALUE ON THE DMM. RECORD THE DATA IN THE DATA LOG IN THE APPROPRIATE
SPOT.

INT: RECORD DATA FOR ALL TESTS OF THE SAME FREQUENCY, THEN GO ON TO ANOTHER
FREQUENCY SO YOU DON'T HAVE TO SET THE FREQUENCY AS OFTEN.

EQUIPMENT IS INTERCONNECTED AS FOLLOWS:

DOTTED LINE IF PRE AMP IS NOT REQUIRED


SET CONTROLS ON NEUTRIK
MAIN FRAME:
PLOT MODE: SINGLE
PAPER SPEED: 3mm/s

INPUT MODULE:

INPUT: UNBALANCED

INPUT IMPEDANCE: 600 Ohms

INPUT RANGE: -40db OR -20db DEPENDING UPON WHERE YOU WANT PEN TO WRITE ON
PAPER

VERNIER; CALIBRATE

0db REFERENCE: dbm (0.775V)


HP - FILTER: (FLAT)
DISPLAY SCALE: 50db
WRITING SPEED: 20mm/s

OUTPUT MODULE

OUTPUT RANGE: PROBABLY -10 TO 0 DEPENDING ON THE GAIN OF PRE AMP AND
AMPLIFIER.

VERNIER: POSITION DEPENDS ON GAIN OF POWER AMP AND PRE AMP


0db REFERENCE: dbm (0.775V)
MUTE/ON: DEPENDS IF YOU WANT OUTPUT OR NOT. TO PLAY IT SAFE, IF NOT TESTING
PUT ON MUTE.

(START) FREQUENCY: 20 HZ
SWEEP FUNCTION: CONTINUOUS WARBLE 1/3 OCTAVE

SET UP OF DMM (DIGITAL MULTI METER)

SET UP METER FOR: AC


VOLTS
20 VOLT SCALE
RELATIVE OFF
TURN ON MICROPHONE POWER SUPPLY (FROM OFF TO ON IN ONE CLICK). MAKE SURE
THAT THE BATTERY LEVEL METER NEEDLE IS IN THE "GREEN". IF IT IS IN THE RED,
STOP, TURN OFF POWER SUPPLY AND CHANGE THE BATTERIES.

IF WE ARE ALL SET, MAKE CERTAIN THAT NEUTRIK IS IN MUTE AND THE OUTPUT
LEVEL IS VERY MUCH ATTENUATED (LOW LEVEL OUTPUT). TURN ON THE POWER
AMPLIFIER; TURN ON NEUTRIK; TURN OFF MUTE (IN OTHER WORDS, OUTPUT IS NOW
ON). ADJUST THE LEVEL OF THE NEUTRIK UNTIL THE LEVEL AT THE OUTPUT OF THE
POWER AMPLIFIER IS 2.3 VOLTS, AS MEASURED WITH THE DVM.

BEFORE STARTING THE TEST, MAKE CERTAIN THAT THE SWITCH ON THE NAMEPLATE IS
IN THE "NORMAL" POSITION OR DOWN.

WITH THE NEUTRIK STARTING AT 20 HZ AND WITH SUFFICIENT GAIN ON THE INPUT TO
GIVE A READING THAT IS BASICALLY THE MIDDLE OF THE CHART FROM 20HZ TO
20KHZ, WE CAN NOW START THE NEUTRIK AND OBSERVE THE OUTPUT RECEIVED BY THE
MICROPHONE AT ONE METER. YOU SHOULD SEE A RISING OUTPUT FROM 20HZ TO
APPROXIMATELY 40HZ AND THEN FALLING SLIGHTLY TO A LEVEL RESPONSE AS
PICTURED BELOW.

THIS IS AN IDEALIZED RESPONSE AND YOU WON'T EVER SEE ANYTHING QUITE THIS
FLAT WHEN YOU ARE TESTING IN REAL LIFE.
A POINT TO OBSERVE IS THE RELATIVE USE OF THE BASS "BUMP" TO THE MID BAND
REGION. IT SHOULD BE ABOUT 6 db OR SO. THE MID RANGE IS AROUND THE 500 HZ
RANGE. THE BASS "BUMP" IS WHERE THE PEAK AT LOW FREQUENCY IS. YOU WILL
PROBABLY SEE A FALL OFF IN LEVEL AT THE HIGHER FREQUENCIES AS WELL; THIS
SHOULD BE SLIGHT AND GRADUAL IN APPEARANCE.

RECORD THE SERIAL NUMBER ON THE CHART, SIDE OF ROOM, DATE AND NEUTRIK
SETTINGS IN BOXES PROVIDED ON CHART PAPER.
CALIPER WOOFER DC 3.1- 3.4 MR-TW DC 3.4 - 3.8 MR-TW CONNECTIONS
TOP-WHITE
BOTTOM-GREEN

WOOFER MR-TW
100hz 1Khz PHASE @ 100hz 1Khz 10Khz PHASE @ 1.5khz

3.6 - 4.0 12.1-12.9 0 4.5 - 4.9 7.0 - 7.5 0

CALIPER SIGNATURE WOOFER DC 2.5 - 3.0 MR-TW DC 2.0 - 2.5 MR-TW CONNECTIONS
TOP-BLUE
BOTTOM-BROWN

WOOFER MR-TW
100hz 1Khz PHASE @ 100hz 1Khz N 10Khz PHASE @ 1.5Khz
N L H
3.1 - 3.6 10.5 - 10.8 0 2.8 - 3.3 3.3 - 4.0 4.3 - 5.0 3.1 - 3.8 0

DUETTA II UP TO S/N 4248 WOOFER DC 4.7 - 5.0 MR-TW DC 2.4 - 2.8 MR-TWCONNECTIONS
TOP-GREY
BOTTOM-BROWN
WOOFER MR-TW I MR-TW 2

100hz 1Khz PHASE @ 100hz 1Khz 10Khz 1Khz 10Khz PHASE @ 1.5Khz

5.1 - 5.6 15.0 - 16.8 0 5.6 - 6.2 9.7 - 10.7 4.9 - 5.4 8.7 - 9.6 0

DUETTA II AFTER S/N 4248 WOOFER DC 3.1 - 3.4 MR-TW DC 2.4 - 2.8 MR-TW CONNECTIONS
TOP-GREY
BOTTOM-BROWN
WOOFER MR-TW 1 MR-TW 2

100hz 1Khz PHASE @ 100hz 1Khz 10Khz 1Khz 10Khz PHASE @ 1.5Khz

3.7 - 4.1 12.7 - 14.1 0 3.6 - 4.0 5.6 - 6.2 3.7 - 4.1 5.3 - 5.9 0
DUETTA SIGNATURE WOOFER DC 3.1 - 3.4 MR-TW DC 2.4 - 2.8 MR-TW CONNECTIONS
TOP-BLUE
BOTTOM-BROWN
WOOFER MR-TW

100hz 1Khz PHASE @ 100hz 1Khz 10Khz PHASE @ 1.5Khz


N L H
3.6 - 4.1 12.0 - 14.5 0 3.5 - 4 4.0 - 4.6 4.7 - 5.6 2.8 - 3.1 0

SCINTILLA WOOFER DC 0.7 - 1.0 MR DC 0.1 - 0.3 TW DC 1.2 - 1.4 MR-TWCONNECTIONS


TOP-BLUE
MIDDLE-RED
WOOFER MR-TW BOTTOM-WHITE

100hz 10Khz PHASE @ 100hz 100hz 1Khz 5Khz 10Khz PHASE @ 1KhZ

0.9 - 1.2 32 - 35 0 6.4 - 7.0 0.9 - 1.1 3.1 - 3.3 3.3 - 3.6 0

DIVA WOOFER DC 3.8 - 4.1 MR DC 2.9 - 3.4 TW DC 0.8 - 1.1

WOOFER MR TW

PHASE @ 100hz PHASE @ 1.5Khz PHASE @ 15Khz


0 0 0

ORIGINAL FULL RANGE WOOFER DC 1.6 - 1.9 MR DC 0.16 - 0.25 TW DC 0.9 - 1.1

WOOFER MR T'W

70hz PHASE @ 70hz 1kHz PHASE @ 1Khz 10Khz PHASE @ 10Khz

3.9 - 4.4 0 8.0 - 8.7 0 2.1 - 2.5 0