1 Introduction
This document contains full overview of test and software calibration procedures for
GeniuMT/JokerMT devices.
1.1 Entering test menu
Enter service area using service password. Test Menu is located in Service / Check 1. Gas test
menu is available only on gas devices. You can use gas or service password to access it in
Service / Check2.
M. Czop 1/6
Version: 2015.05.20 Test and software calibration procedures.
SW >= 3.08 GeniusMT / JokerMT
To select test enter test number using arrows. It can be done only when any of the test is not
running.
M. Czop 2/6
Version: 2015.05.20 Test and software calibration procedures.
SW >= 3.08 GeniusMT / JokerMT
To activate test press button START. To Stop test you can press button STOP. Buttons are
located at bottom of the page.
2 Check1
Test volume /
ID Description Valve Test duration
300 Calibration TopSteam 200ml
310 Calibration BottomSteam 200ml
320 Calibration SteamDischarge 500ml
330 Flowmeter test TopSteam 5 min
340 Flowmeter test BottomSteam 5 min
350 Valve test TopSteam 1 min
360 Valve test BottomSteam 1 min
370 Valve test SteamDischarge 1 min
M. Czop 3/6
Version: 2015.05.20 Test and software calibration procedures.
SW >= 3.08 GeniusMT / JokerMT
During calibration of steam valves (300 and 310), the flow meters must be
disabled. You can enable them after calibration. Parameter for flowmeter is
here in Optrions 222 FirstFlowMeter and 223 SecondFlowMeter.
Prepare container for water volume measurement. You should collect the
water which is going through the tested valve.
Start proper test and wait until it ends.
Measure volume of water in container.
Enter measured volume in message box.
Press button to confirm new value.
Repeat procedure one more time to verify calibration achieve better
accuracy.
2.3.2 Flowmeter test 330, 340
This test open valve and show if flowmeter is counting. It can be run only if
flowmeter is enabled. Using this test you can check if flowmeter is properly
connected and not blocked.
2.3.3 Valve test 350, 360, 370
This test open valve for one minute and display calculated (or measured) water
volume.
2.4 Various actuator test
ID Actuator
400 Main Contactor
410 Cooking Chamber Light
420 Loud Speaker
430 Condensation Hood 1
431 Condensation Hood 2
440 Exhaust Air Flap Open
441 Exhaust Air Flap Close
450 Door Opener
M. Czop 4/6
Version: 2015.05.20 Test and software calibration procedures.
SW >= 3.08 GeniusMT / JokerMT
ID Chamber
520 1
521 2
2.6 Autoclean
Warning! After pump activation, the decontamination step is required before cooking!
Decontamination step can’t be skipped.
ID Actuator
600 Cleaning Agent Pump
610 Rinse Agent Pump
620 Cleaning Pole Motor
630 Autoclean Water Valve
640 Soft Water Valve
Note that test 640 is available only if device has water group with ACL system connected to
hard and soft water. In this case 640 activate soft water valve and 630 activate hard water
valve.
2.7 Temperature test
3 Check 2
M. Czop 5/6
Version: 2015.05.20 Test and software calibration procedures.
SW >= 3.08 GeniusMT / JokerMT
Each test will ignite the burner. Ignition step takes 30s, then it will go to operation mode. Gas
fan speed is determined by maximum or minimum PWM value from gas configuration
(parameters Gas / 613, 614, 616 617)
You can also adjust fan speed manually using slider.
M. Czop 6/6