Sei sulla pagina 1di 18

19/8/2017 C18 Generator Set N1D00001-UP(SEBP5558 - 15) - Documentation

Previous Screen
Welcome: r460caxg
Product: GENERATOR SET
Model: C18 GENERATOR SET N1D00101
Configuration: C18 Generator Set N1D00001-UP

Troubleshooting
EMCP3
Media Number -RENR7902-12 Publication Date -01/05/2014 Date Updated -07/05/2014

i06849520

Diagnostic Trouble Code List


SMCS - 7569

Reference: For a full explanation of the use of the enter function key that is referenced in this section, refer to
the Systems Operation, "Electronic Control Module (Generator Set)" section of this publication.

Table 1 lists the diagnostic trouble codes for the genset. The column titled "Display Text String" is the
information that is displayed on the EMCP 3 control panel. In order to view the "Suspect Parameter Number"
(SPN) and the "Failure Mode Identifier" (FMI), press the "Enter" key while viewing the "Display Text String".

If the diagnostic code was generated from the "Electronic Control Module" (ECM) for the engine, refer to the
Systems Operation, Testing and Adjusting manual for the particular engine. Perform the diagnostic procedure as
indicated by the SPN and FMI information.

If the diagnostic code is generated from the EMCP 3 ECM for the generator set, then refer to Table 1 and refer to
the information that is in the "Troubleshooting Topic" column.

Note: The "Emergency Shutdown Override Mode Active Warning" requires a level 3 password in order to clear
the code. All remaining listed codes require a level 1 password in order to clear the code.

Portions of this material are reprinted with permission from SAE J1939DA_201607© 2016 SAE International.
SAE International is not responsible for any use or translation of this material, in whole or in part. Please contact
SAE International to obtain a complete copy of SAE J1939DA_201607, the official definitive source of this
standard.

Table 1
Trouble Codes
Suspect Failure
Parameter Mode Troubleshooting
Code Description Display Text String
Number Identifier Topic
(SPN) (FMI)
EXT TANK HIGH Digital Input Circuit
External Tank High Fuel
38 0 FUEL LEVEL Fault and Analog Input
Level Shutdown
SHUTDOWN Circuit Fault

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=… 1/18
19/8/2017 C18 Generator Set N1D00001-UP(SEBP5558 - 15) - Documentation

38 1 External Tank Low Fuel EXT TANK LOW Digital Input Circuit
Level Shutdown FUEL LEVEL Fault and Analog Input
SHUTDOWN Circuit Fault
EXT TANK FUEL
External Tank Fuel Level Analog Input Circuit
38 3 LEVEL SENSOR
Sensor Short High Fault
SHORT HIGH
EXT TANK FUEL
External Tank Fuel Level Analog Input Circuit
38 4 LEVEL SENSOR
Sensor Short Low Fault
SHORT LOW
EXT TANK HIGH Digital Input Circuit
External Tank High Fuel
38 15 FUEL LVL Fault and Analog Input
Level Warning
WARNING Circuit Fault
EXT TANK LOW Digital Input Circuit
External Tank Low Fuel
38 17 FUEL LVL Fault and Analog Input
Level Warning
WARNING Circuit Fault
HIGH STARTING Digital Input Circuit
High Starting Air
82 0 AIR PRES Fault and Analog Input
Pressure Shutdown
SHUTDOWN Circuit Fault
Digital Input Circuit
Low Starting Air LOW STARTING AIR
82 1 Fault and Analog Input
Pressure Shutdown PRES SHUTDOWN
Circuit Fault
STARTING AIR PRES
Starting Air Pressure Analog Input Circuit
82 3 SENSOR SHORT
Sensor Short High Fault
HIGH
STARTING AIR PRES
Starting Air Pressure Analog Input Circuit
82 4 SENSOR SHORT
Sensor Short Low Fault
LOW
HIGH STARTING Digital Input Circuit
High Starting Air
82 15 AIR PRES Fault and Analog Input
Pressure Warning
WARNING Circuit Fault
Digital Input Circuit
Low Starting Air LOW STARTING AIR
82 17 Fault and Analog Input
Pressure Warning PRES WARNING
Circuit Fault
HIGH FUEL
high fuel pressure
94 00 PRESSURE
shutdown
SHUTDOWN
LOW FUEL
low fuel pressure
94 01 PRESSURE
shutdown
SHUTDOWN
HIGH FUEL
high fuel pressure
94 15 PRESSURE
warning
WARNING
94 16 high fuel pressure derate HIGH FUEL
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=… 2/18
19/8/2017 C18 Generator Set N1D00001-UP(SEBP5558 - 15) - Documentation

PRESSURE DERATE
LOW FUEL
low fuel pressure
94 17 PRESSURE
warning
WARNING
LOW FUEL
94 18 low fuel pressure derate
PRESSURE DERATE
High Fuel Filter HIGH FUEL FLTR Digital Input Circuit
95 0 Differential Pressure DIFF PRES Fault and Analog Input
Shutdown SHUTDOWN Circuit Fault
Low Fuel Filter LOW FUEL FILTER Digital Input Circuit
95 1 Differential Pressure DIFF PRES Fault and Analog Input
Shutdown SHUTDOWN Circuit Fault
Fuel Filter Differential FUEL FLTER DIFF
Analog Input Circuit
95 3 Pressure Sensor Short PRES SENSOR
Fault
High SHORT HIGH
Fuel Filter Differential FUEL FLTR DIFF
Analog Input Circuit
95 4 Pressure Sensor Short PRES SENSOR
Fault
Low SHORT LOW
High Fuel Filter HIGH FUEL FLTR Digital Input Circuit
95 15 Differential Pressure DIFF PRES Fault and Analog Input
Warning WARNING Circuit Fault
Low Fuel Filter LOW FUEL FILTER Digital Input Circuit
95 17 Differential Pressure DIFF PRES Fault and Analog Input
Warning WARNING Circuit Fault
Digital Input Circuit
High Fuel Level HIGH FUEL LEVEL
96 0 Fault and Analog Input
Shutdown SHUTDOWN
Circuit Fault
Digital Input Circuit
Low Fuel Level LOW FUEL LEVEL
96 1 Fault and Analog Input
Shutdown SHUTDOWN
Circuit Fault
FUEL LEVEL
Fuel Level Sensor Short Analog Input Circuit
96 3 SENSOR SHORT
High Fault
HIGH

FUEL LEVEL
Fuel Level Sensor Short Analog Input Circuit
96 4 SENSOR SHORT
Low Fault
LOW
Digital Input Circuit
High Fuel Level HIGH FUEL LEVEL
96 15 Fault and Analog Input
Warning WARNING
Circuit Fault
Digital Input Circuit
LOW FUEL LEVEL
96 17 Low Fuel Level Warning Fault and Analog Input
WARNING
Circuit Fault

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=… 3/18
19/8/2017 C18 Generator Set N1D00001-UP(SEBP5558 - 15) - Documentation

98 0 High Engine Oil Level HIGH ENGINE OIL Digital Input Circuit
Shutdown LVL SHUTDOWN Fault and Analog Input
Circuit Fault
Digital Input Circuit
Low Engine Oil Level LOW ENGINE OIL
98 1 Fault and Analog Input
Shutdown LVL SHUTDOWN
Circuit Fault
ENGINE OIL LEVEL
Engine Oil Level Sensor Analog Input Circuit
98 3 SENSOR SHORT
Short High Fault
HIGH
ENGINE OIL LEVEL
Engine Oil Level Sensor Analog Input Circuit
98 4 SENSOR SHORT
Short Low Fault
LOW
Digital Input Circuit
High Engine Oil Level HIGH ENGINE OIL
98 15 Fault and Analog Input
Warning LVL WARNING
Circuit Fault
Digital Input Circuit
Low Engine Oil Level LOW ENGINE OIL
98 17 Fault and Analog Input
Warning LVL WARNING
Circuit Fault
High Oil Filter HIGH OIL FILTER Digital Input Circuit
99 0 Differential Pressure DIFF PRES Fault and Analog Input
Shutdown SHUTDOWN Circuit Fault
Low Oil Filter LOW OIL FILTER Digital Input Circuit
99 1 Differential Pressure DIFF PRES Fault and Analog Input
Shutdown SHUTDOWN Circuit Fault
Oil Filter Differential OIL FILTER DIFF
Analog Input Circuit
99 3 Pressure Sensor Short PRES SENSOR
Fault
High SHORT HIGH
Oil Filter Differential OIL FILTER DIFF
Analog Input Circuit
99 4 Pressure Sensor Short PRES SENSOR
Fault
Low SHORT LOW
High Oil Filter HIGH OIL FILTER Digital Input Circuit
99 15 Differential Pressure DIFF PRES Fault and Analog Input
Warning WARNING Circuit Fault
Low Oil Filter LOW OIL FILTER Digital Input Circuit
99 17 Differential Pressure DIFF PRES Fault and Analog Input
Warning WARNING Circuit Fault
Data Link circuit Fault
Low Engine Oil Pressure LOW ENGINE OIL
100 1 and Digital Input
Shutdown PRESS SHUTDOWN
Circuit Fault
ENG OIL PRES
Engine Oil Pressure
100 3 SENSOR SHORT
Sensor Short High
HIGH
100 4 Engine Oil Pressure ENG OIL PRES
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=… 4/18
19/8/2017 C18 Generator Set N1D00001-UP(SEBP5558 - 15) - Documentation

Sensor Short Low SENSOR SHORT


LOW
Data Link circuit Fault
Low Engine Oil Pressure LOW ENGINE OIL
100 17 and Digital Input
Warning PRESS WARNING
Circuit Fault
High Air Filter HIGH AIR FILTER Digital Input Circuit
107 0 Differential Pressure DIFF PRES Fault and Analog Input
Shutdown SHUTDOWN Circuit Fault
Low Air Filter LOW AIR FILTER Digital Input Circuit
107 1 Differential Pressure DIFF PRES Fault and Analog Input
Shutdown SHUTDOWN Circuit Fault
Air Filter Differential AIR FILTER DIFF
Analog Input Circuit
107 3 Pressure Sensor Short PRES SENSOR
Fault
High SHORT HIGH
Air Filter Differential AIR FILTER DIFF
Analog Input Circuit
107 4 Pressure Sensor Short PRES SENSOR
Fault
Low SHORT LOW
High Air Filter HIGH AIR FILTER Digital Input Circuit
107 15 Differential Pressure DIFF PRES Fault and Analog Input
Warning WARNING Circuit Fault
Low Air Filter LOW AIR FILTER Digital Input Circuit
107 17 Differential Pressure DIFF PRES Fault and Analog Input
Warning WARNING Circuit Fault
HIGH ENGINE Data Link Circuit Fault
High Engine Coolant
110 0 COOLANT TEMP and Digital Input
Temperature Shutdown
SHUTDOWN Circuit Fault
Engine Coolant ENG COOLANT
110 3 Temperature Sensor Short TEMP SENSOR
High SHORT HI
Engine Coolant ENG COOLANT
110 4 Temperature Sensor Short TEMP SENSOR
Low SHORT LO
HIGH ENGINE Data Link Circuit Fault
High Engine Coolant
110 15 COOLANT TEMP and Digital Input
Temperature Warning
WARNING Circuit Fault
Data Link Circuit Fault
Low Engine Coolant LOW COOLANT
110 17 and Digital Input
Temperature Warning TEMP WARNING
Circuit Fault
Digital Input Circuit
High Engine Coolant HIGH ENG COOL
111 0 Fault and Analog Input
Level Shutdown LEVEL SHUTDOWN
Circuit Fault
111 1 Low Engine Coolant LOW ENG COOL Digital Input Circuit
Level Shutdown LEVEL SHUTDOWN Fault and Analog Input
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=… 5/18
19/8/2017 C18 Generator Set N1D00001-UP(SEBP5558 - 15) - Documentation

Circuit Fault
ENGINE COOLANT
Engine Coolant Level Analog Input Circuit
111 3 LEVEL SENSOR
Sensor Short High Fault
SHORT HIGH
ENGINE COOLANT
Engine Coolant Level Analog Input Circuit
111 4 LEVEL SENSOR
Sensor Short Low Fault
SHORT LOW
Digital Input Circuit
High Engine Coolant HIGH ENG COOL
111 15 Fault and Analog Input
Level Warning LEVEL WARNING
Circuit Fault
Digital Input Circuit
Low Engine Coolant LOW ENG COOL
111 17 Fault and Analog Input
Level Warning LEVEL WARNING
Circuit Fault
Digital Input Circuit
High Fire Extinguisher HIGH FIRE EXTNG
137 0 Fault and Analog Input
Pressure Shutdown PRES SHUTDOWN
Circuit Fault
Digital Input Circuit
Low Fire Extinguisher LOW FIRE EXTNG
137 1 Fault and Analog Input
Pressure Shutdown PRES SHUTDOWN
Circuit Fault
Fire Extinguisher FIRE EXTING PRES
Analog Input Circuit
137 3 Pressure Sensor Short SENSOR SHORT
Fault
High HIGH
Fire Extinguisher FIRE EXTNG PRES
Analog Input Circuit
137 4 Pressure Sensor Short SENSOR SHORT
Fault
Low LOW

Digital Input Circuit


High Fire Extinguisher HIGH FIRE EXTNG
137 15 Fault and Analog Input
Pressure Warning PRES WARNING
Circuit Fault
Digital Input Circuit
Low Fire Extinguisher LOW FIRE EXTNG
137 17 Fault and Analog Input
Pressure Warning PRES WARNING
Circuit Fault
LOW BATTERY
Low Battery Charging
167 17 CHARGING SYS Charging System
System Voltage Warning
VOLT WARN
HIGH BATTERY
High Battery Voltage
168 0 VOLTAGE Charging System
Shutdown
SHUTDOWN
HIGH BATTERY
High Battery Voltage
168 15 VOLTAGE Charging System
Warning
WARNING
LOW BATTERY
Low Battery Voltage
168 17 VOLTAGE Charging System
Warning
WARNING
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=… 6/18
19/8/2017 C18 Generator Set N1D00001-UP(SEBP5558 - 15) - Documentation

171 0 High Ambient Air HIGH AMBIENT AIR Digital Input Circuit
Temperature Shutdown TEMP SHUTDOWN Fault and Analog Input
Circuit Fault
Digital Input Circuit
Low Ambient Air LOW AMBIENT AIR
171 1 Fault and Analog Input
Temperature Shutdown TEMP SHUTDOWN
Circuit Fault
AMBIENT AIR TEMP
Ambient Air Temperature Analog Input Circuit
171 3 SENSOR SHORT
Sensor Short High Fault
HIGH
AMBIENT AIR TEMP
Ambient Air Temperature Analog Input Circuit
171 4 SENSOR SHORT
Sensor Short Low Fault
LOW
Digital Input Circuit
High Ambient Air HIGH AMBIENT AIR
171 15 Fault and Analog Input
Temperature Warning TEMP WARNING
Circuit Fault
Digital Input Circuit
Low Ambient Air LOW AMBIENT AIR
171 17 Fault and Analog Input
Temperature Warning TEMP WARNING
Circuit Fault
Digital Input Circuit
High Exhaust HIGH EXHAUST
173 0 Fault and Analog Input
Temperature Shutdown TEMP SHUTDOWN
Circuit Fault
Digital Input Circuit
Low Exhaust LOW EXHAUST
173 1 Fault and Analog Input
Temperature Shutdown TEMP SHUTDOWN
Circuit Fault
EXHAUST
Exhaust Temperature TEMPERATURE Analog Input Circuit
173 3
Sensor Short High SENSOR SHORT Fault
HIGH
EXHAUST
Exhaust Temperature TEMPERATURE Analog Input Circuit
173 4
Sensor Short Low SENSOR SHORT Fault
LOW
EXHAUST TEMP
Exhaust Temperature
173 8 SIGNAL
Signal Abnormal
ABNORMAL
Digital Input Circuit
High Exhaust HIGH EXHAUST
173 15 Fault and Analog Input
Temperature Warning TEMP WARNING
Circuit Fault
Digital Input Circuit
Low Exhaust LOW EXHAUST
173 17 Fault and Analog Input
Temperature Warning TEMP WARNING
Circuit Fault
175 0 High Engine Oil HIGH ENGINE OIL Digital Input Circuit
Temperature Shutdown TEMP SHUTDOWN Fault and Analog Input
Circuit Fault
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=… 7/18
19/8/2017 C18 Generator Set N1D00001-UP(SEBP5558 - 15) - Documentation

Digital Input Circuit


Low Engine Oil LOW ENGINE OIL
175 1 Fault and Analog Input
Temperature Shutdown TEMP SHUTDOWN
Circuit Fault
ENGINE OIL TEMP
Engine Oil Temperature Analog Input Circuit
175 3 SENSOR SHORT
Sensor Short High Fault
HIGH
ENGINE OIL TEMP
Engine Oil Temperature Analog Input Circuit
175 4 SENSOR SHORT
Sensor Short Low Fault
LOW
Digital Input Circuit
High Engine Oil HIGH ENGINE OIL
175 15 Fault and Analog Input
Temperature Warning TEMP WARNING
Circuit Fault
Digital Input Circuit
Low Engine Oil LOW ENGINE OIL
175 17 Fault and Analog Input
Temperature Warning TEMP WARNING
Circuit Fault
Engine Over Speed ENGINE OVER Engine Over Speed
190 0
Shutdown SPEED SHUTDOWN Warning
Engine Under Speed ENGINE UNDER Engine Under Speed
190 1
Shutdown SPEED SHUTDOWN Warning
ENGINE SPEED
Engine Speed Sensor Engine Speed Circuit
190 2 SENSOR
Erratic or Not Present Fault
ERRATIC/LOST
Engine Speed Sensor ENGINE SPEED Engine Speed Circuit
190 5
Open SENSOR OPEN Fault
Engine Under Speed ENGINE UNDER Engine Under Speed
190 17
Warning SPEED WARNING Warning
SOFTWARE
Software Version
234 31 VERSION
Mismatch
MISMATCH
SCADA DATA LINK Data Link Circuit
625 11 SCADA Data Link Fault
FAULT Fault
PRIMARY DATA Data Link Circuit
639 11 Primary Data Link Fault
LINK FAULT Fault
Custom Event #1 High CUSTOM EVENT #1 Digital Input Circuit
701 0
Shutdown HIGH SHUTDOWN Fault
Custom Event #1 Low CUSTOM EVENT #1 Digital Input Circuit
701 1
Shutdown LOW SHUTDOWN Fault
Custom Event #1 High CUSTOM EVENT #1 Digital Input Circuit
701 15
Warning HIGH WARNING Fault
Custom Event #1 Low CUSTOM EVENT #1 Digital Input Circuit
701 17
Warning LOW WARNING Fault
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=… 8/18
19/8/2017 C18 Generator Set N1D00001-UP(SEBP5558 - 15) - Documentation

CUSTOM EVENT #1 Digital Input Circuit


701 31 Custom Event #1 Status
STATUS ACTIVE Fault
Custom Event #2 High CUSTOM EVENT #2 Digital Input Circuit
702 0
Shutdown HIGH SHUTDOWN Fault
Custom Event #2 Low CUSTOM EVENT #2 Digital Input Circuit
702 1
Shutdown LOW SHUTDOWN Fault
Custom Event #2 High CUSTOM EVENT #2 Digital Input Circuit
702 15
Warning HIGH WARNING Fault
Custom Event #2 Low CUSTOM EVENT #2 Digital Input Circuit
702 17
Warning LOW WARNING Fault
CUSTOM EVENT #2 Digital Input Circuit
702 31 Custom Event #2 Status
STATUS ACTIVE Fault
Custom Event #3 High CUSTOM EVENT #3 Digital Input Circuit
703 0
Shutdown HIGH SHUTDOWN Fault
Custom Event #3 Low CUSTOM EVENT #3 Digital Input Circuit
703 1
Shutdown LOW SHUTDOWN Fault
Custom Event #3 High CUSTOM EVENT #3 Digital Input Circuit
703 15
Warning HIGH WARNING Fault
Custom Event #3 Low CUSTOM EVENT #3 Digital Input Circuit
703 17
Warning LOW WARNING Fault
CUSTOM EVENT #3 Digital Input Circuit
703 31 Custom Event #3 Status
STATUS ACTIVE Fault
Custom Event #4 High CUSTOM EVENT #4 Digital Input Circuit
704 0
Shutdown HIGH SHUTDOWN Fault
Custom Event #4 Low CUSTOM EVENT #4 Digital Input Circuit
704 1
Shutdown LOW SHUTDOWN Fault
Custom Event #4 High CUSTOM EVENT #4 Digital Input Circuit
704 15
Warning HIGH WARNING Fault
Custom Event #4 Low CUSTOM EVENT #4 Digital Input Circuit
704 17
Warning LOW WARNING Fault
CUSTOM EVENT #4 Digital Input Circuit
704 31 Custom Event #4 Status
STATUS ACTIVE Fault
Custom Event #5 High CUSTOM EVENT #5 Digital Input Circuit
705 0
Shutdown HIGH SHUTDOWN Fault
Custom Event #5 Low CUSTOM EVENT #5 Digital Input Circuit
705 1
Shutdown LOW SHUTDOWN Fault
Custom Event #5 High CUSTOM EVENT #5 Digital Input Circuit
705 15
Warning HIGH WARNING Fault
705 17 Custom Event #5 Low CUSTOM EVENT #5 Digital Input Circuit
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=… 9/18
19/8/2017 C18 Generator Set N1D00001-UP(SEBP5558 - 15) - Documentation

Warning LOW WARNING Fault


CUSTOM EVENT #5 Digital Input Circuit
705 31 Custom Event #5 Status
STATUS ACTIVE Fault
Custom Event #6 High CUSTOM EVENT #6 Digital Input Circuit
706 0
Shutdown HIGH SHUTDOWN Fault
Custom Event #6 Low CUSTOM EVENT #6 Digital Input Circuit
706 1
Shutdown LOW SHUTDOWN Fault
Custom Event #6 High CUSTOM EVENT #6 Digital Input Circuit
706 15
Warning HIGH WARNING Fault
Custom Event #6 Low CUSTOM EVENT #6 Digital Input Circuit
706 17
Warning LOW WARNING Fault
CUSTOM EVENT #6 Digital Input Circuit
706 31 Custom Event #6 Status
STATUS ACTIVE Fault
Custom Event #7 High CUSTOM EVENT #7
707 0
Shutdown HIGH SHUTDOWN
Custom Event #7 Low CUSTOM EVENT #7
707 1
Shutdown LOW SHUTDOWN
Custom Event #7 High CUSTOM EVENT #7
707 15
Warning HIGH WARNING
Custom Event #7 Low CUSTOM EVENT #7
707 17
Warning LOW WARNING
CUSTOM EVENT #7
707 31 Custom Event #7 Status
STATUS
Custom Event #8 High CUSTOM EVENT #8
708 0
Shutdown HIGH SHUTDOWN
Custom Event #8 Low CUSTOM EVENT #8
708 1
Shutdown LOW SHUTDOWN
Custom Event #8 High CUSTOM EVENT #8
708 15
Warning HIGH WARNING
Custom Event #8 Low CUSTOM EVENT #8
708 17
Warning LOW WARNING
CUSTOM EVENT #8
708 31 Custom Event #8 Status
STATUS
CUSTOM EVENT #9
709 31 Custom Event #9 Status
STATUS
CUSTOM EVENT #10
710 31 Custom Event #10 Status
STATUS
CUSTOM EVENT #11
711 31 Custom Event #11 Status
STATUS
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage… 10/18
19/8/2017 C18 Generator Set N1D00001-UP(SEBP5558 - 15) - Documentation

712 31 Custom Event #12 Status CUSTOM EVENT #12


STATUS
CUSTOM EVENT #13
713 31 Custom Event #13 Status
STATUS
CUSTOM EVENT #14
714 31 Custom Event #14 Status
STATUS
CUSTOM EVENT #15
715 31 Custom Event #15 Status
STATUS
CUSTOM EVENT #16
716 31 Custom Event #16 Status
STATUS
Digital Output #1 Short DIGITAL OUTPUT 1 Digital Output Circuit
924 3
High SHORT HIGH Fault
Digital Output #2 Short DIGITAL OUTPUT 2 Digital Output Circuit
925 3
High SHORT HIGH Fault
Emergency Stop EMERGENCY STOP Digital Input Circuit
970 31
Shutdown SHUTDOWN Fault
High Generator Bearing HIGH GEN BEARING Digital Input Circuit
1122 0 #1 Temperature #1 TEMP Fault and Analog Input
Shutdown SHUTDOWN Circuit Fault
Low Generator Rear LOW GEN REAR Digital Input Circuit
1122 1 Bearing Temperature BEARING TEMP Fault and Analog Input
Shutdown SHUTDOWN Circuit Fault
GEN REAR
Generator Rear Bearing
BEARING TEMP Analog Input Circuit
1122 3 Temperature Sensor Short
SENSOR SHORT Fault
High
HIGH
GEN REAR
Generator Rear Bearing
BEARING TEMP Analog Input Circuit
1122 4 Temperature Sensor Short
SENSOR SHORT Fault
Low
LOW
High Rear Generator HIGH GEN REAR Digital Input Circuit
1122 15 Bearing Temperature BEARING TEMP Fault and Analog Input
Warning WARNING Circuit Fault
Low Generator Rear LOW GEN REAR Digital Input Circuit
1122 17 Bearing Temperature BEARING TEMP Fault and Analog Input
Warning WARNING Circuit Fault
High Generator Winding HIGH GEN
1124 0 #1 Temperature WINDING #1 TEMP
Shutdown SHUTDOWN
High Generator Winding HIGH GEN
1124 15 #1 Temperature Warning WINDING #1 TEMP
WARNING
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage… 11/18
19/8/2017 C18 Generator Set N1D00001-UP(SEBP5558 - 15) - Documentation

1125 0 High Generator Winding HIGH GEN


#2 Temperature WINDING #2 TEMP
Shutdown SHUTDOWN
HIGH GEN
High Generator Winding
1125 15 WINDING #2 TEMP
#2 Temperature Warning
WARNING

High Generator Winding HIGH GEN


1126 0 #3 Temperature WINDING #3 TEMP
Shutdown SHUTDOWN
HIGH GEN
High Generator Winding
1126 15 WINDING #3 TEMP
#3 Temperature Warning
WARNING
Accessory Data Link ACCESSORY DATA Data Link Circuit
1231 11
Fault LINK FAULT Fault
Fuel Tank Leak (Fuel Digital Input Circuit
1239 31 FUEL TANK LEAK
Rupture Basin) Fault
UNEXPECTED
Unexpected Engine
1383 11 ENGINE
Shutdown
SHUTDOWN
HIGH GAS
High Gas Pressure
1390 0 PRESSURE
Shutdown
SHUTDOWN
LOW GAS
Low Gas Pressure
1390 1 PRESSURE
Shutdown
SHUTDOWN
HIGH GAS
High Gas Pressure
1390 15 PRESSURE
Warning
WARNING
LOW GAS
Low Gas Pressure
1390 17 PRESSURE
Warning
WARNING
ENGINE FAILURE
Engine Failure to Start Engine Overcrank
1664 31 TO START
Shutdown Warning
SHUTDOWN
HIGH RIGHT Digital Input Circuit
High Right Exhaust
2433 0 EXHAUST TEMP Fault and Analog Input
Temperature Shutdown
SHUTDOWN Circuit Fault
LOW RIGHT Digital Input Circuit
Low Right Exhaust
2433 1 EXHAUST TEMP Fault and Analog Input
Temperature Shutdown
SHUTDOWN Circuit Fault
2433 3 Right Exhaust RIGHT EXHAUST Analog Input Circuit
Temperature Sensor Short TEMP SENSOR Fault
High SHORT HIGH
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage… 12/18
19/8/2017 C18 Generator Set N1D00001-UP(SEBP5558 - 15) - Documentation

Right Exhaust RIGHT EXHAUST


Analog Input Circuit
2433 4 Temperature Sensor Short TEMP SENSOR
Fault
Low SHORT LOW
Right Exhaust RIGHT EXHAUST
2433 8 Temperature Signal TEMP SGNL
Abnormal ABNORMAL
HIGH RIGHT Digital Input Circuit
High Right Exhaust
2433 15 EXHAUST TEMP Fault and Analog Input
Temperature Warning
WARNING Circuit Fault
LEFT EXHAUST
Left Exhaust Temperature
2434 8 TEMP SGNL
Signal Abnormal
ABNORMAL
LOW RIGHT Digital Input Circuit
Low Right Exhaust
2433 17 EXHAUST TEMP Fault and Analog Input
Temperature Warning
WARNING Circuit Fault
HIGH LEFT Digital Input Circuit
High Left Exhaust
2434 0 EXHAUST TEMP Fault and Analog Input
Temperature Shutdown
SHUTDOWN Circuit Fault
LOW LEFT Digital Input Circuit
Low Left Exhaust
2434 1 EXHAUST TEMP Fault and Analog Input
Temperature Shutdown
SHUTDOWN Circuit Fault
LEFT EXHAUST
Left Exhaust Temperature Analog Input Circuit
2434 3 TEMP SENSOR
Sensor Short High Fault
SHORT HIGH
LEFT EXHAUST
Left Exhaust Temperature Analog Input Circuit
2434 4 TEMP SENSOR
Sensor Short Low Fault
SHORT LOW
HIGH LEFT Digital Input Circuit
High Left Exhaust
2434 15 EXHAUST TEMP Fault and Analog Input
Temperature Warning
WARNING Circuit Fault
LOW LEFT Digital Input Circuit
Low Left Exhaust
2434 17 EXHAUST TEMP Fault and Analog Input
Temperature Warning
WARNING Circuit Fault
GEN OVER
Generator Over Generator Over
2436 0 FREQUENCY
Frequency Shutdown Frequency Warning
SHUTDOWN
GEN UNDER
Generator Under Generator Under
2436 1 FREQUENCY
Frequency Shutdown Frequency Warning
SHUTDOWN
Engine Speed-Generator ENG SPEED-GEN
2436 2 Output Frequency FREQ MISMATCH Engine Speed Warning
Mismatch Warning WARN

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage… 13/18
19/8/2017 C18 Generator Set N1D00001-UP(SEBP5558 - 15) - Documentation

2436 12 Generator Output GEN AC METERING Generator Output


Sensing System Failure SYS FAILURE Sensing Circuit Fault
GEN OVER
Generator Over Generator Over
2436 15 FREQUENCY
Frequency Warning Frequency Warning
WARNING
GEN UNDER
Generator Under Generator Under
2436 17 FREQUENCY
Frequency Warning Frequency Warning
WARNING
GEN OVER
Generator Over Voltage Generator Over Voltage
2440 0 VOLTAGE
Shutdown Warning
SHUTDOWN
GEN UNDER
Generator Under Voltage Generator Under
2440 1 VOLTAGE
Shutdown Voltage Warning
SHUTDOWN
GEN OVER
Generator Over Voltage Generator Over Voltage
2440 15 VOLTAGE
Warning Warning
WARNING
GEN UNDER
Generator Under Voltage Generator Under
2440 17 VOLTAGE
Warning Voltage Warning
WARNING
GEN OVER
Generator Over Current Generator Over Current
2448 0 CURRENT
Shutdown Warning
SHUTDOWN
GEN OVER
Generator Over Current Generator Over Current
2448 15 CURRENT
Warning Warning
WARNING
GEN REVERSE
Generator Reverse Power Generator Reverse
2452 1 POWER
Shutdown Power Warning
SHUTDOWN
Generator High Power GENERATOR HIGH
2452 15
Warning POWER WARNING
Generator Reverse Power GEN REVERSE Generator Reverse
2452 17
Warning POWER WARNING Power Warning
SERV MAINT
Service Maintenance Service Maintenance
2648 31 INTERVAL
Interval Warning Interval Warning
WARNING
Engine Controller Not ENG CONTROLLER
3543 9
Responding NOT RESPONDING
Utility Breaker System UTILITY BREAKER
3546 11
Fault SYSTEM FAULT
3783 31 Engine Inlet Manifold ENGINE INLET
Charge Combustion MANIFOLD CHRG

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage… 14/18
19/8/2017 C18 Generator Set N1D00001-UP(SEBP5558 - 15) - Documentation

COMBUSTION
EPS SUPPLYING
3829 31 EPS Supplying Load
LOAD
CUSTOM EVENT #17
3880 31 Custom Event #17 Status
STATUS
CUSTOM EVENT #18
3881 31 Custom Event #18 Status
STATUS
CUSTOM EVENT #19
3882 31 Custom Event #19 Status
STATUS
CUSTOM EVENT #20
3883 31 Custom Event #20 Status
STATUS
CUSTOM EVENT #21
3888 31 Custom Event #21 Status
STATUS
CUSTOM EVENT #22
3889 31 Custom Event #22 Status
STATUS
CUSTOM EVENT #23
3890 31 Custom Event #23 Status
STATUS
CUSTOM EVENT #24
3891 31 Custom Event #24 Status
STATUS
CUSTOM EVENT #25
3892 31 Custom Event #25 Status
STATUS
CUSTOM EVENT #26
3893 31 Custom Event #26 Status
STATUS
CUSTOM EVENT #27
3894 31 Custom Event #27 Status
STATUS
CUSTOM EVENT #28
3895 31 Custom Event #28 Status
STATUS
CUSTOM EVENT #29
3896 31 Custom Event #29 Status
STATUS
CUSTOM EVENT #30
3897 31 Custom Event #30 Status
STATUS
Custom Event #31 Status CUSTOM EVENT #31
3898 31
STATUS
CUSTOM EVENT #32
3899 31 Custom Event #32 Status
STATUS
CUSTOM EVENT #33
3904 31 Custom Event #33 Status
STATUS
CUSTOM EVENT #34
3905 31 Custom Event #34 Status
STATUS
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage… 15/18
19/8/2017 C18 Generator Set N1D00001-UP(SEBP5558 - 15) - Documentation

3906 31 Custom Event #35 Status CUSTOM EVENT #35


STATUS
CUSTOM EVENT #36
3907 31 Custom Event #36 Status
STATUS
CUSTOM EVENT #37
3908 31 Custom Event #37 Status
STATUS
CUSTOM EVENT #38
3909 31 Custom Event #38 Status
STATUS
CUSTOM EVENT #39
3910 31 Custom Event #39 Status
STATUS
CUSTOM EVENT #40
3911 31 Custom Event #40 Status
STATUS
CUSTOM EVENT #41
3912 31 Custom Event #41 Status
STATUS
CUSTOM EVENT #42
3913 31 Custom Event #42 Status
STATUS
CUSTOM EVENT #43
3914 31 Custom Event #43 Status
STATUS
CUSTOM EVENT #44
3915 31 Custom Event #44 Status
STATUS
CUSTOM EVENT #45
3920 31 Custom Event #45 Status
STATUS
CUSTOM EVENT #46
3921 31 Custom Event #46 Status
STATUS
CUSTOM EVENT #47
3922 31 Custom Event #47 Status
STATUS
CUSTOM EVENT #48
3923 31 Custom Event #48 Status
STATUS
CUSTOM EVENT #49
3924 31 Custom Event #49 Status
STATUS
CUSTOM EVENT #50
3925 31 Custom Event #50 Status
STATUS
CUSTOM EVENT #51
3926 31 Custom Event #51 Status
STATUS
CUSTOM EVENT #52
3927 31 Custom Event #52 Status
STATUS
CUSTOM EVENT #53
3928 31 Custom Event #53 Status
STATUS
3929 31 Custom Event #54 Status CUSTOM EVENT #54
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage… 16/18
19/8/2017 C18 Generator Set N1D00001-UP(SEBP5558 - 15) - Documentation

STATUS
CUSTOM EVENT #55
3930 31 Custom Event #55 Status
STATUS
CUSTOM EVENT #56
3931 31 Custom Event #56 Status
STATUS
AIR DAMPER Digital Input Circuit
4000 31 Air Damper Closed
CLOSED Fault
ATS IN NORMAL Digital Input Circuit
4001 31 ATS in Normal Position
POSITION Fault
ATS IN
ATS in Emergency Digital Input Circuit
4002 31 EMERGENCY
Position Fault
POSITION
BATTERY CHARGER Digital Input Circuit
4003 31 Battery Charger Failure
FAILURE Fault
Generator Circuit GENERATOR Digital Input Circuit
4004 31
Breaker Closed BREAKER CLOSED Fault
Utility Circuit Breaker UTILITY BREAKER Digital Input Circuit
4005 31
Closed CLOSED Fault
ENGINE IN Engine Cooldown
4006 31 Engine in Cooldown
COOLDOWN Warning
Generator Control Not in GEN CONTROL NOT Generator Control Not
4007 31
Automatic Warning IN AUTO WARNING In Automatic Warning
GENERATOR
Generator Breaker
4009 31 BREAKER FAILURE
Failure to Open
TO OPEN
Utility Breaker Failure to UTILITY BREAKER
4010 31
Open FAILURE TO OPEN
GENERATOR
Generator Breaker
4011 31 BREAKER FAILURE
Failure to Close
TO CLOSE
Utility Breaker Failure to UTILITY BREAKER
4012 31
Close FAILURE TO CLOSE
Generator Circuit GENERATOR
4013 31
Breaker Open BREAKER OPEN
UTILITY BREAKER
4014 31 Utility Breaker Open
OPEN
UTIL TO GEN
Utility to Generator
TRANSFER
4015 0 Transfer Failure
FAILURE
Shutdown
SHUTDOWN

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage… 17/18
19/8/2017 C18 Generator Set N1D00001-UP(SEBP5558 - 15) - Documentation

4015 15 Utility to Generator UTIL TO GEN


Transfer Failure Warning TRANSFER
FAILURE WARNING
GEN TO UTIL
Generator to Utility
4016 15 TRANSFER
Transfer Failure Warning
FAILURE WARNING
4017 31 Loss of Utility LOSS OF UTILITY
GENERATOR
Generator Breaker
4018 31 BREAKER LOCKED
Locked Out
OUT
Utility Breaker Locked UTILITY BREAKER
4019 31
Out LOCKED OUT
4028 31 Earth Fault EARTH FAULT
4029 31 Earth Leakage EARTH LEAKAGE
LOW BATT
Low Battery Cranking
4256 17 CRANKING
Voltage Warning
VOLTAGE WARN

Copyright 1993 - 2017 Caterpillar Inc. Sat Aug 19 2017 08:14:32 GMT-0500 (Hora est. Pacífico, Sudamérica)