Enclosed please find a CD containing Version 3.10 of the TANK (API-650/653 Design & Analysis) program.
The changes made to the program for Version 3.10 include:
Version 3.10 has passed internal QA and should not present any problems. If you have any questions,
comments, suggestions, or problems, please contact the TANK development staff.
Regards,
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Important Notes/Technical Changes
th
TANK 3.10 implements the changes made to the 11 Edition of API-650. There are a number of major
changes to the Code in this Addendum. These changes mean that tank evaluations to earlier editions of API-
th
650 (and earlier versions of TANK) may yield different results when re-evaluated by 11 Edition rules. The
most significant changes in this Edition that will impact computational results are:
• The stress calculation for the annular base plate thickness determination has been changed.
• A new equation form is provided for the frangible area limit.
• A number of corrections have been made to the equations found in Appendix E.
• The roof live load has been reduced from 25 psf to 20 psf.
• The removal of the 2nd equation from Appendix F Section F.5.1.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
TANK LICENSE AGREEMENT
Licensor: COADE/Engineering Physics Software, Inc., 12777 Jones Rd., Ste. 480, Houston,
Texas 77070
LICENSE GRANT
In return for the payment of the license fee associated with the acquisition of the Licensed
Program(s) from COADE, COADE hereby grants you the following non-exclusive rights with
regard to the Licensed Program(s):
a. Use of the License Program(s) on one machine. Under no circumstance is the License
Program to be executed without a COADE External Software Lock (ESL).
b. To transfer the Licensed Program(s) and license it to a third party if the third party
acknowledges in writing its agreement to accept the Licensed Program(s) under the terms and
conditions of this License Agreement; if you transfer the Licensed Program(s), you must at the
same time either transfer all copies whether printed or in machine-readable form to the same
party or destroy any copies not so transferred; the requirement to transfer and/or destroy copies
of the Licensed Program(s) also pertains to any and all modifications and portions of Licensed
Program(s) contained or merged into other programs.
You agree to reproduce and include the copyright notice as it appears on the Licensed Program(s)
on any copy, modification or merged portion of the Licensed Program(s).
THIS LICENSE DOES NOT GIVE YOU ANY RIGHT TO USE COPY, MODIFY, OR
TRANSFER THE LICENSED PROGRAM(S) OR ANY COPY, MODIFICATION OR
MERGED PORTION THEREOF, IN WHOLE OR IN PART, EXCEPT AS EXPRESSLY
PROVIDED IN THIS LICENSE AGREEMENT. IF YOU TRANSFER POSSESSION OF ANY
COPY, MODIFICATION OR MERGED PORTION OF THE LICENSED PROGRAM(S) TO
ANOTHER PARTY, THE LICENSE GRANTED HEREUNDER TO YOU IS
AUTOMATICALLY TERMINATED.
TERM
This License Agreement is effective upon acceptance and use of the Licensed Program(s) until
terminated in accordance with the terms of this License Agreement. You may terminate the
License Agreement at any time by destroying the Licensed Program(s) together with all copies,
modifications, and merged portions thereof in any form. This License Agreement will also
terminate upon conditions set forth elsewhere in this Agreement or automatically in the event you
fail to comply with any term or condition of this License Agreement. You hereby agree upon
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
such termination to destroy the Licensed Program(s) together with all copies, modifications, and
merged portions thereof in any form.
LIMITED WARRANTY
The Licensed Program(s), i.e. the tangible proprietary software, is provided “AS IS” WITHOUT
WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED AND EXPLICITLY
EXCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR PURPOSE. The entire risk as to the quality and performance of the Licensed
Program(s) is with you.
Some jurisdictions do not allow the exclusion of limited warranties, and, in those jurisdictions the
above exclusions may not apply. This Limited Warranty gives you specific legal rights, and you
may also have other rights which vary from one jurisdiction to another.
COADE does not warrant that the functions contained in the Licensed Program(s) will meet your
requirements or that the operation of the program will be uninterrupted or error free.
COADE does warrant, however, that the CD(s), i.e. the tangible physical medium on which the
Licensed Program(s) is furnished, to be free from defects in materials and workmanship under
normal use for a period of ninety (90) days from the date of delivery to you as evidenced by a
copy of your receipt.
COADE warrants that any program errors will be fixed by COADE, at COADE’s expense, as
soon as possible after the problem is reported and verified. However, only those customers
current on their update/maintenance contracts are eligible to receive the corrected version of the
program.
ENTIRE AGREEMENT
This written Agreement constitutes the entire agreement between the parties concerning the
Licensed Program(s). No agent, distributor, salesman or other person acting or representing
themselves to act on behalf of COADE has the authority to modify or supplement the limited
warranty contained herein, nor any of the other specific provisions of this Agreement, and no
such modifications or supplements shall be effective unless agreed to in writing by an officer of
COADE having authority to act on behalf of COADE in this regard.
LIMITATIONS OF REMEDIES
COADE’s entire liability and your exclusive remedy shall be:
a. The replacement of any CD not meeting COADE’s “Limited Warranty” as defined herein and
which is returned to COADE or an authorized COADE dealer with a copy of your receipt, or
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, OR FOR ANY CLAIM BY
ANY OTHER PARTY.
GENERAL
You may not sublicense, assign, or transfer your rights under this License Agreement or the
Licensed Program(s) except as expressly provided in this License Agreement. Any attempt
otherwise to sublicense, assign or transfer any of the rights, duties or obligations hereunder is
void and constitutes a breach of this License Agreement giving COADE the right to terminate as
specified herein. This Agreement is governed by the laws of the State of Texas, United States of
America.
The initial license fee includes 1 year of support, maintenance and enhancements to the program.
After the first 1 year term, such updates and support are optional at the then current update fee.
Questions concerning this License Agreement, and all notices required herein, shall be made by
contacting COADE in writing at COADE, 12777 Jones RD., Ste. 480, Houston, Texas, 77070, or
by telephone, 281-890-4566.
EXPORT RESTRICTIONS
You acknowledge the Software is subject to U.S. export jurisdiction. You agree to comply with
all applicable international and national laws that apply to the Software, including the U.S. Export
Administration Regulations, as well as end-user, end-use, and destination restrictions issued by
U.S. and other governments. For additional information see http://www.bis.doc.gov.”
DISCLAIMER - TANK
Copyright (c) COADE/Engineering Physics Software, Inc., 2009, all rights reserved.
This proprietary software is the property of COADE/Engineering Physics Software, Inc. and is
provided to the user pursuant to a COADE/Engineering Physics Software, Inc. program license
agreement containing restrictions on its use. It may not be copied or distributed in any form or
medium, disclosed to third parties, or used in any manner except as expressly permitted by the
COADE/Engineering Physics Software, Inc. program license agreement.
THIS SOFTWARE IS PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND,
EITHER EXPRESSED OR IMPLIED. COADE/ENGINEERING PHYSICS SOFTWARE, INC.
SHALL NOT HAVE ANY LIABILITY TO THE USER IN EXCESS OF THE TOTAL
AMOUNT PAID TO COADE UNDER THE COADE/ENGINEERING PHYSICS SOFTWARE,
INC. LICENSE AGREEMENT FOR THIS SOFTWARE. IN NO EVENT WILL
COADE/ENGINEERING PHYSICS SOFTWARE, INC. BE LIABLE TO THE USER FOR
ANY LOST PROFITS OR OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES
ARISING OUT OF USE OR INABILITY TO USE THE SOFTWARE EVEN IF
COADE/ENGINEERING PHYSICS, INC. HAS BEEN ADVISED AS TO THE POSSIBILITY
OF SUCH DAMAGES. IT IS THE USERS RESPONSIBILITY TO VERIFY THE RESULTS
OF THE PROGRAM.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
TANK - API 650/653 ANALYSIS-
3.10
Last Revised 09/2008
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
i
Contents
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
ii Contents
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Contents iii
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
iv Contents
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Contents v
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
1-1
C H A P T E R 1
Chapter 1 Introduction
In This Chapter
TANK Overview ........................................................ 1-2
Technical Support....................................................... 1-3
Program Interface Generalities................................... 1-4
Program Capabilities .................................................. 1-6
Program Hardware Requirements .............................. 1-8
Software Revision Procedures.................................... 1-9
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
1-2 TANK - API 650/653 ANALYSIS-3.10
TANK Overview
TANK is a computer-based software tool for the design and analysis of large storage tanks, which
implements the API-650 and API-653 design codes. TANK incorporates interactive dialogs for
user input, cell specific help for guidance and information, input validation to avoid run time
errors, and extensive diagnostics to assist in problem resolution.
This manual provides detailed instructions for the installation, configuration, and operation of the
program. Every effort has been made to create a user interface as obvious as possible. However,
when in doubt, rely on the help system, which can be launched by pressing F1.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Introduction 1-3
Technical Support
COADE understands the engineer’s need to produce efficient, economical, and expeditious
designs. To that end, COADE has a staff of professionals ready to address questions raised by
users. TANK support is available by telephone, e-mail, fax, the web site, and by mail. It is
expected, however, that questions focus on the current version of the program.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
1-4 TANK - API 650/653 ANALYSIS-3.10
As briefly mentioned in the Introduction, the program interface has been designed to be obvious
and easy to use. Several of the more important interface characteristics are discussed in this
section.
Help
One of the most important features of TANK is the help system, which is designed to be available
anytime input is required from the user. Help on a particular input cell can be obtained by
pressing the [F1] key. Once the help system has been activated, the appropriate information is
displayed to the user in an interactive window. When the help text pertains to an input cell which
is units specific, the help text includes the expected input units in the title line. Note, these unit
labels are dynamic and will change to reflect the currently active units file.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Introduction 1-5
Units
The second important feature of the TANK interface is the units system. The units system is
intended to provide consistent units sets while providing flexibility to switch between them. The
following points detail the characteristics of the units system:
Input Files - New and existing input files are always presented using the currently active set
of units. The expected units for each data cell are displayed on the dialog.
Selecting a Units File - Most users will work in one predominate units system, it is important
to select and set this system. The selection of the desired units system can be accomplished in
the tool\configuration program. The four standard COADE supplied units systems are listed in
Appendix B.
Reviewing Output - Output reports are always generated at the time of the request, using the
currently active units file. TANK provides the user with the ability to switch units for output
generation. This provides the ability to review the output in several sets of units without re-
running the analysis.
Creating Units Sets - COADE supplies four standard units sets with TANK. In some instances
additional sets may be required. A utility program can be launched from the Main Menu to
generate additional units files.
In-Field Computations
The third important feature of the interface is the ability to perform simple computations in the
input cells. For example, a corrosion allowance of 3/32 can be entered as 3/32 instead of
0.09375. The four basic math operations (addition, subtraction, multiplication, and division) are
supported in the input cells. This input calculator feature is quite useful for quick conversions
when a calculator is out of reach.
Error Checking
A final point to note about the TANK interface is the error detection and diagnostic reporting
module. Even though TANK validates the user’s input data, there is still the potential for abort
conditions to arise during the analysis. These conditions can be caused by system problems (full
hard disks) or API Code restrictions (Appendix A limits thicknesses to 1/2 inch). When such a
fatal condition occurs, the program attempts to trap the error, assign it a numeric value which is
indexed to a database, and finally reports the problem to the user. This diagnostic reporting can
be launched from any module of the program and utilizes the same interface as the help system.
Once the review of a specific error message is complete, the diagnostic utility allows the review
of additional error messages if necessary. Upon exit from the diagnostic utility, user control is
returned to the Main menu.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
1-6 TANK - API 650/653 ANALYSIS-3.10
Program Capabilities
TANK incorporates the major considerations of API-650 Section 5, and several of the Appendices.
This includes:
Shell course thickness and fluid height computations according to either the variable point
method or the one foot method.
Wind girder computations for the top and up to five intermediate girders.
Minimum metal temperature reporting.
Shell course thickness and fluid height computations according to Appendix A.
Seismic computations according to Appendix E.
Internal pressure considerations according to Appendix F.
Grillage computations according to Appendix I.
Material modifications due to temperature according to Appendix M.
Cycle Life computations according to Appendix M.
Nozzle flexibilities and limiting loads according to Appendix P, including the limiting load
interaction diagrams.
Stainless Steel considerations according to Appendix S.
External pressure computations according to Appendix V.
An alternate nozzle stiffness calculation routine according to PVP-1279.
Tank sizing/costing scratch-pad
A Material Database editor
TANK also incorporates the following considerations from API-653:
Material modifications according to Section 2.3.
Shell Settlement evaluation according to Appendix B.
Retiring thicknesses and remaining corrosion allowance.
Corroded hydrotest case
Shell thickness evaluations using individual joint efficiencies and “L” locations
Bottom Plate minimum thickness determinations
Hydrotest heights
TANK can also design or analyze a supported cone roof according to the procedures outlined in
Brownell & Young. TANK also incorporates venting computations from API-2000.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Introduction 1-7
TANK relies on a great deal of data specified in the API codes. This includes the material data
from Table 5.2, and digitized data from Appendix P. Other data tables have also been
incorporated into the program where necessary.
Every effort is made to insure that TANK is up to date with the current codes. (COADE
continuously upgrades the software.)
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
1-8 TANK - API 650/653 ANALYSIS-3.10
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Introduction 1-9
COADE software products are not static; they change continually to reflect engineering code
addenda, operational enhancements, user requests, operating system modifications, and
corrections. New versions are planned and targeted for a specific release date. However, there
may be corrections necessary to the currently shipping version, before the next version can be
released. When this occurs, a correction to the currently shipping version is made. This correction
is referred to as a Build.
Changes and corrections are accumulated until an error producing incorrect results is found.
When this occurs, the build is finalized, announced, and posted to the Web site. Some COADE
users have expressed concern over tracking, archiving, and distributing the various builds
generated between major releases. In order to alleviate this problem for our users, all maintenance
builds for new releases contain all previous builds. In other words, Build Y contains Build X.
This increases the download size and time required to obtain the build, but only one build is
required at any given time.
Identifying Builds
When posted on the Web builds are identified with the program identifier and the date the Build
was generated. Builds have a naming convention, and resemble the following format:
<TK><Version><date>.exe.
The file name format consists of a 2 character program abbreviation, the version indicator and the
build date. Once the file has been downloaded and installed, the build date displays at the bottom
right side of the Main menu, and also displays by clicking \HELP\ABOUT.
Announcing Builds
When a build becomes available all users who have "registered" the software are sent an email
announcement. It is therefore imperative that you register the software following installation.
Obtaining Builds
Builds are posted to the website (http://www.coade.com). The builds are arranged in sub-
directories by program. Each file contained in the directory includes a description defining what it
contains, its size, and the date it was created. Determine which build file you need and download
it.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
1-10 TANK - API 650/653 ANALYSIS-3.10
Installing Builds
The Build file is an InstallShield™ update package. Simply double click the build file(exe),
follow any prompts and the software installation will update appropriately.
Detecting/Checking Builds
When a build is ready to be released, the Main menu module is revised to reflect the build level.
This allows the user to see, on the Main Program menu, which build is in use. To see which
program modules have been modified, you can run a COADE utility program from within the
program directory.
From the UTILITY/TOOLS menu, select the COADE EXE Scanner option. This option scans each of
the EXE modules in the program directory and lists its size, memory requirements, and build
bevel. A sample display from this utility is shown in the figure below.
Reviewing this table shows which modules have been patched and to what level.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Introduction 1-11
To reinstall an older version of the software, the distribution CD from COADE should be installed
first. Then, the last build should be installed. Each build includes the modifications made in all
prior builds.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
2-1
C H A P T E R 2
Chapter 2 Installation
In This Chapter
Installation Overview ................................................. 2-2
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
2-2 TANK - API 650/653 ANALYSIS-3.10
Installation Overview
To begin the installation of TANK, insert the CD into the drive. The installation routine will start
and the following screen displays.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 2 Installation 2-3
Installing TANK
The installation begins by clicking Install. When Install is activated, the dialog changes to show
all of the installation options, as shown in the figure below.
Selecting Install ESL Driver launches Aladdin’s stand alone installation for the HASP driver,
necessary to access the hardware key. Selecting Install Acrobat Reader launches Adobe’s stand
alone installation for Acrobat Reader, necessary to access the TANK documentation files.
Selecting Install TANK begins the installation of TANK as shown below. The first operation is
the extraction of the MSI file.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
2-4 TANK - API 650/653 ANALYSIS-3.10
As installation begins, a dialog opens displaying a progress indicator and the name of the file
extracted.
Note: It is best if nothing else is running while the installation program runs. Most unsuccessful
installation attempts can be attributed to other software running at the same time as the
installation.
After the program completes extracting all the necessary files the Welcome dialog displays.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 2 Installation 2-5
The dialog to set the installation folder is presented next, as shown in the figure below.
To install the software in another location, click Change to the right of the dialog. A new dialog
displays and at the bottom of the dialog, type the new destination folder, or use the buttons on the
right to browse for the desired location. After the proper destination folder has been defined,
click OK. This returns control to the dialog displayed above, from which Next should be clicked
to continue the installation process.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
2-6 TANK - API 650/653 ANALYSIS-3.10
The next dialog encountered is the Select ESL Color dialog. This selection defines whether a
Local or Network key will be used, which determines which driver gets loaded. After selecting
the appropriate key click Next.
An additional dialog is presented to allow one last chance to abort the installation. Clicking
Install on this dialog transfers the software from the CD to the target destination directory.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 2 Installation 2-7
As the installation progresses, the status is shown in a series of progress bars, as depicted in the
figure below.
Once the files have been transferred, the Aladdin device driver installation routine is invoked to
install the driver for the hardware lock, as shown in the figure below.
After successfully installing the HASP device driver, the following dialog displays. If this dialog
does not display, installation of the driver was not successful and the software will not run.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
2-8 TANK - API 650/653 ANALYSIS-3.10
Once the driver installation terminates, the installation routine cleans up and displays the next
dialog. If the “readme.doc” file is to be viewed, enable this check box before clicking Finish.
Since a device driver was loaded, it is a good idea to restart Windows. The final dialog provides
options to immediately restart Windows, or terminate the installation. Select the appropriate
button.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 2 Installation 2-9
Command
Cmd= setup.exe /v"/qb PROPERTY_NAME="value" PROPERTY_NAME2="Value""
The /v switch is to pass msi commands
The /qb is a silent switch
Example:
Setup.exe /v"/qb INSTALL_SILENT="Yes" ESL_COLOR="Green""
This example installs silent with ESL color green.
Setup.exe /v"/qb INSTALL_SILENT="Yes" ESL_COLOR="Red"
ESL_ON_MACHINE="Yes""
This example installs silent with ESL color red and ESL install locally.
Properties
INSTALLDIR (The path to load the installation files)
<target_dir>
ESL_ON_MACHINE (This is only set if ESL color is red which is if the ESL will be on local
machine or server)
Yes
No
No
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
3-1
C H A P T E R 3
In This Chapter
Customizing TANK ................................................... 3-2
Computation Control.................................................. 3-4
Anchor Bolt Database ................................................ 3-7
Database Definitions .................................................. 3-8
This chapter explains how to customize TANK once it has been installed.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
3-2 TANK - API 650/653 ANALYSIS-3.10
Customizing TANK
Through the configuration program, users can configure program computations and databases.
The configuration program can be launched directly from the Main menu.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 3 Program Configuration 3-3
The first task of this module is to locate an existing setup file to use as a starting template. The
program first looks for an existing configuration file in the current directory. If a configuration
file is not found in the current directory, the configuration file from the program installation
directory is used. Once the template configuration file has been read, the program displays its
menu, shown in Figure 3.2.
The configuration menu consists of two tabbed dialog screens, each of which is discussed in the
following sections. A complete list of the configuration options with their default settings is
contained in Appendix D (see "Appendix D - Default Configuration Directives" on page 15-1).
Users should note that modifications to the configuration only affect analysis results if the input
data is re-error checked. This is required since the configuration directives are written to the
analysis files by the error checker.
The [D] buttons (when active) can be clicked to return the associated directive to its default value.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
3-4 TANK - API 650/653 ANALYSIS-3.10
Computation Control
The computation control directives provide a way to modify the operation of the program. The
directives in this category are described in the paragraphs below.
This option can be used to disable the 10% + 5 psi increase, which may be necessary to comply
with vendor requirements or other calculation procedures. The wind pressure computed is based
on the user specified value of wind velocity (on page 6-14), and then modified as indicated by this
directive.
Corroded Nozzles
This directive allows the user to indicate whether or not the flexibility computations of API-650
Appendix P should consider corrosion. BY DEFAULT CORROSION IS NOT CONSIDERED.
If this check box is checked, the corrosion of the first shell course is used to modify the thickness
used in the Appendix P computations FOR THE DESIGN CASE ONLY.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 3 Program Configuration 3-5
Unchecked - Indicates that the TEST case should not be corroded. This is consistent with API-
650 and is the program default.
Checked - Indicates that the TEST case should include the corrosion allowance specified by the
user.
If this directive is checked, then the methodology of Section F.7.1 will be implemented for all
three thickness computation methods. Essentially, the Operating Liquid Level will be increased
by (P/12G).
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
3-6 TANK - API 650/653 ANALYSIS-3.10
Note that increasing the convergence tolerance reduces the accuracy of the solution.
Alternatively, instead of changing the tolerance, the iteration limit may be increased.
MAX - When this directive is set to MAX, the wind girder computation routine uses the
maximum thickness for the shell courses, obtained from the design and test cases, IGNORING
corrosion. The reasoning behind this setting is that the entire shell course will not be completely
corroded.
DESIGN - When this directive is set to DESIGN, the wind girder computation routine uses the
DESIGN thickness less any user specified corrosion allowance.
FOURIER SERIES - Implements the procedure outlined in the paper "Simple Method Calculates
Tank Shell Distortion", by F. A. Koczwara, published in Hydrocarbon Processing, August 1980.
LEAST SQUARES - Employs a least squares approach to the solution of the optimum cosine
curve.
Setting this directive to 0.0 disables thickness round up and the computed values of shell
thickness are reported, un-altered, in the output.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 3 Program Configuration 3-7
Note that the wind pressure computed according to Section 5.9.7.1 (based on the wind velocity
(on page 6-14)) is used for the wind girder design, the wind pressure according to Section 5.11 is
used for Over Turning Stability. This directive only affects which wind moment is passed into
Appendix F for the allowed pressure in Section F.4.2.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
3-8 TANK - API 650/653 ANALYSIS-3.10
Database Definitions
The directives in this group are used to set the data files the program references for units,
structural shapes and materials. The directives in this category are described in the paragraphs
below.
Material File
The possible selections for this cell are determined by the program by scanning the installation
directory. Only valid COADE supplied material files will be placed in this selection list.
Units File
The possible selections for this cell are determined by the program by scanning the current
directory, followed by a scan of the installation directory. Duplicate files found in the installation
directory are ignored. A maximum of ten units files can be manipulated by this program.
The user may generate additional custom units files if necessary via the Tools menu option Make
Units
This cell specifies which units file will be used to generate all subsequent new input files, and all
output reviews.
Structural Database
This directive allows the selection of the structural database, for use in the supported cone roof
design module. Database files are supplied by COADE and support U.S. as well as International
shape libraries.
Germany UK
Korea U.S.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
4-1
C H A P T E R 4
This chapter provides the user with instructions on how to get TANK running without reading the
manual. It is assumed, that the program has been properly installed and configured, as detailed in
In This Chapter
Starting TANK ........................................................... 4-2
the Installation and Program Configuration chapters.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
4-2 TANK - API 650/653 ANALYSIS-3.10
Starting TANK
Start TANK by selecting TANK from the Start menu or the desktop icon. The main menu is the
control center for the user. From here jobs can be selected, defined, analyzed, and reviewed.
Use the Edit menu, or the toolbar icons to specify or update the input. Once the input has been
defined, it must be error checked. The error checker validates the data for numeric consistency
(i.e. diameters and thicknesses must be positive), and to enforce and API code requirements (i.e.
thicknesses can not be less than the course above). If there are errors in the input data, analysis is
prohibited - the user must correct these errors before proceeding. Warning messages are
acceptable to the program - users should ensure that warning messages are acceptable to the
current tank analysis. Details of the error checker are discussed in the 7 Chapter.
Assuming that error checking completed successfully, an intermediate data file is created for
analysis; and control is returned to the main menu. From here, the user should select Analyze
Only, which launches the analysis module. The analysis module displays the program execution
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 4 Quick Start 4-3
screen which monitors the status of the solution. Upon completion of the analysis, a solution data
file is created, and control is again returned to the main menu.
Once a solution data file is available, the user may select one of the Output menu options. Note,
the analysis does not have to be re-run (unless the input data changes) prior to each output review
session. As long as the job input parameters remain fixed, the output module can be launched as
many times as required to interactively review the results or generate reports.
When the user has finished reviewing the output, quit the output processor. User control then
returns to the Main menu. The steps outlined above are summarized below.
1. From the Start menu click TANK.
2. Select a job, either new or old.
3. Define the input data. The error checker is launched from the Analysis menu.
4. Analyze the input data by clicking Analyze Only from the Analysis menu.
5. Select an option from the Output menu to review the analysis results and generate output
reports.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
5-1
C H A P T E R 5
In This Chapter
The Main Menu .......................................................... 5-2
The File Menu ............................................................ 5-3
The Input Menu .......................................................... 5-4
The Analysis Menu .................................................... 5-5
The Output Menu ....................................................... 5-6
The Tools Menu ......................................................... 5-7
The Diagnostics Menu................................................ 5-8
The ESL Menu ........................................................... 5-10
The View Menu.......................................................... 5-13
The Help Menu........................................................... 5-14
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
5-2 TANK - API 650/653 ANALYSIS-3.10
As discussed in Quick Start launch TANK by selecting TANK from the Start menu, or by double
clicking the desktop icon. The Main menu is the point from which all decisions are made
concerning what job is to be analyzed and what program function is to be launched.
The menu options allow input data definition, analysis, output review, configuration, utility tools,
diagnostics, and help. The toolbar buttons are primarily concerned with the input options, but
also include output review (both text and graphics), the Material Database editor, and ESL
review.
The Main menu contains all of the options available in TANK. The options are arranged in
groups, corresponding to the major topics on the menu. Each of these groups is discussed in the
following sections.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 5 Utilizing the Main Menu 5-3
The File menu consists of the standard Windows options for opening, saving, and printing the
input for a specific job. Note that recently accessed jobs can be accessed from the MRU list.
This MRU list allows quick access to the most recently accessed jobs, without the need to browse
the hard disk.
Note that TANK can automatically start up and read in the data for the last job analyzed. This can
be accomplished by selecting TOOLS\CONFIGURATION.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
5-4 TANK - API 650/653 ANALYSIS-3.10
The Input menu contains all of the input options necessary to define a TANK job. The input
menu categorizes the data into logical groups, each accessed from the menu. Note that the icon to
the left of the menu text is identical to the tool bar icon. Both the menu and the tool bar produce
the same input dialog screen.
The input options are discussed in detail in Chapter 6. Upon completion of the input, the
Analysis Menu should be used to verify and/or analyze the job.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 5 Utilizing the Main Menu 5-5
The Analysis Menu contains three options: Error Check, Analyze, and Error Check and
Analyze. TANK will not analyze a job until the input has been successfully error checked. If the
input data successfully passes the error checker, an analysis file for the job is written, with a .TKE
suffix. Details of the error checker can be found in Chapter 7.
Clicking Analyze launches the solution module, which produces the output file for the job. Note
that this option is deactivated until the .TKE file is written by the error checker. The analysis
module performs the solution step, either designing a tank or re-rating a tank, based on the user’s
input parameters.
Each solution step required for a particular job is enabled in bold text. Steps not required are
disabled, grayed out. As each phase is completed, an asterisk is placed to the left of the task
description. The start-up of the analysis processor is dependent on the data file created by the
error checker. If the verified problem data, written to the .TKE file, cannot be located, the
analysis module aborts with a fatal error message and control returns to the Main menu. This
usually indicates that either error checking was not performed, or the input data contained errors
and no .TKE file was generated. In any event, the analysis phase cannot commence without the
verified input data. Details of the analysis processor can be found in Chapter 8.
The Error Check and Analyze option launches the error checker, and if the input passes the
Error Checker, automatically launches the solution module. Control is returned to the user on the
output review control panel.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
5-6 TANK - API 650/653 ANALYSIS-3.10
The Output Menu contains options for viewing text based reports, viewing graphical results, and
changing the time stamp in the report headers. For viewing text based reports, three options are
available: overwrite reports, append reports, and review latest reports.
Overwrite Reports - Creates a new set of output reports, in the current units system,
completely replacing any existing reports.
Append Reports - Generates a new set of reports, in the current units system, at the end of
the last set of reports.
Review Latest Reports - Launches the output review control panel.
These options allow a variety of output reports to be created, in multiple units systems if
necessary.
Local Graphics - Launches the graphics processor. This processor shows the results of the
analysis graphically. Nozzle load interaction diagrams, shell settlement graphs, and supported
cone roof designs can be viewed in this manner.
Time Stamp - Allows the user to specify the time / date stamp for report headers. If this data
is not specified, the current CPU time and date are used.
Additional details related to output processing can be found in Chapter 9.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 5 Utilizing the Main Menu 5-7
The Tools menu contains miscellaneous options for program configuration, custom units systems,
the Material Database editor, the batch stream processor and a text file review option.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
5-8 TANK - API 650/653 ANALYSIS-3.10
The Diagnostics menu provides the user with a number of tools to verify the integrity of the
software and determine reasons for possible program difficulties.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 5 Utilizing the Main Menu 5-9
Build Version Checker - Scans each of the program modules and reports its internal version
number. This is useful in determining if the current installation is up to date with any
modifications available. This option also aids in detecting out of date modules and improper
program installations. This utility presents the information dialog as shown in Figure 5.8.
This display is initially presented sorted alphabetically by program/module name. However,
clicking on any of the column titles will re-sort the display according to the selected column.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
5-10 TANK - API 650/653 ANALYSIS-3.10
The ESL menu provides access to various functions which allow reporting and modification of
the data stored on the ESL. The ESL is the External Software Lock, which is required to access
the software. In the event there is an access problem with the ESL, most of the Main menu items
will be disabled. However, all options on the ESL menu will still be active (as well as those on
the Diagnostic menu).
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 5 Utilizing the Main Menu 5-11
In addition to allowing basic access to the software, the ESL contains a set of memory registers in
which customer information is stored. This information consists of the client name, and ID
number, date or run limits, versioning information, and the time stamp of the last access. This
information can be viewed by clicking View ESL Information, or by clicking the ESL icon.
The Log File button at the bottom of this window can be used to create a .TXT file of the
information, suitable for transmission to COADE via fax or e-mail. The actual file name will be
“ESLxxxxx.TXT”, where “xxxxx” is the ID number of the ESL. The file will reside in the
program’s \system directory.
Occasionally, some of this date may require updating in the field. These updates encompass
changes requested by the client, usually to extend limits, reset a date, or change the client name.
The first two options of the ESL menu facilitate this task.
Phone Update - Launches an interactive procedure, generating data for the user, and
accepting instructions from the user. This interactive procedure requires the assistance of
COADE personnel, to interact with the user via the telephone.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
5-12 TANK - API 650/653 ANALYSIS-3.10
Generate Fax Codes - Produces a screen with three numeric codes. These codes should be
transmitted to COADE (either via fax or e-mail) with a request for exactly what ESL data
should be modified. This option is similar to the phone update option, except it does not
require the interaction of COADE personnel.
Receive and Enter Fax Codes - Presents a grid on which the user can specify each set of
four numeric codes, as generated by the COADE support staff. Each desired change to the
ESL requires one set of four numeric codes. Each set of four codes should be entered on a
single horizontal row in the grid. When all codes have been entered, click OK to enable the
changes to the ESL. Use this option when you receive the reauthorization codes from COADE.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 5 Utilizing the Main Menu 5-13
The View menu contains standard switches to enable or disable the various toolbars and the status
bar, found in the frame area of the Main menu. By default, all options are enabled.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
5-14 TANK - API 650/653 ANALYSIS-3.10
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 5 Utilizing the Main Menu 5-15
Typically, the HTML help system will be launched during a data input session, when additional
information is required for a particular input item. In this case, pressing F1 displays the help
system, with the selected topic displayed in the viewing (right hand) pane. Once in the HTML
help system, the user is free to browse any other topic simply by navigating through the left hand
pane. Additionally, the Search tab can be used to scan for a particular word or phrase. The
TANK User Guide is provided in on-line HTML format. The entire manual can be reviewed from
this menu option.
Online Documentation - Launches Adobe Acrobat Reader for review of the TANK User
Manual. This document is maintained in PDF format and is installed with the software.
Users wanting a complete hard copy of this manual should print the PDF, instead of the
HTML version.
Animated Tutorials - Launches the tutorials that accompany the software. Use these
tutorials to assist with understanding the usage of the software.
Tip of the Day - Displays the next tip, normally shown at program start-up. The Tip of the
Day is a collection of informative points about the software, normally presented at program
start-up. This display dialog also includes a check box to disable the automatic display of the
tips at start-up.
Info - Presents a dialog containing COADE contact information. The bottom half of this
dialog contains active links to COADE’s website and an e-mail activation.
On-Line Registration - Launches automatically after program installation. This automatic
invocation occurs once. After the first time, this menu option must be used to bring up the
registration form. After completing this form, clicking Send transmits the data on the form to
a web-based List Server.
Check for Updates - Provides access to the COADE web site to determine if there is a newer
update to the version of TANK currently in use. This option saves the user from navigating
through the COADE web site to determine if an update is available. This option should be
launched at least once a month to ensure the software remains current. (An Internet
connection is required to utilize this option.)
About TANK - Presents a dialog showing the current operating system, its version number,
the TANK version number, and the amount of memory installed.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-1
C H A P T E R 6
In This Chapter
Creating Input............................................................. 6-2
The Tank Description Page ........................................ 6-5
General Tank Data...................................................... 6-6
Roof Data ................................................................... 6-20
Seismic Data............................................................... 6-33
Grillage Data .............................................................. 6-36
Nozzle Flexibilities..................................................... 6-38
Shell Settlement Data ................................................. 6-43
API-653 Service Measurement Data .......................... 6-45
Tank Sizing / Costing Scratch-pad............................. 6-51
API-2000 Venting ...................................................... 6-55
Cycle Life Evaluation................................................. 6-58
External Pressure........................................................ 6-60
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-2 TANK - API 650/653 ANALYSIS-3.10
Creating Input
The first step in the design or analysis of a tank is to generate an input file which describes the
characteristics of the tank. Each tank requires an input file, with a unique job name, for each
configuration to be studied. All of the tank particulars and descriptive information are stored in
this input file. The input file name consists of the job name as the prefix, followed by a “.TKI”
suffix.
The input process can be started by selecting any option from the Input menu, or by clicking the
desired toolbar icons.
TANK separates the input data into logical categories. Each category addresses a specific code
requirement on design task. Of all these various groups, the “General Tank Data” group is
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-3
required in all cases, for all tanks. Each of these groups is discussed briefly below, then in
detail in the remaining sections of this chapter.
Title Page - Provides the ability to describe, in words, the tank being studied. This editing buffer
is 75 characters in width by 60 lines in length. Details of the TANK Title Page are discussed in
Section 6.1. Use of this dialog is optional, but is highly recommended. The tool bar icons
associated with this option are:
Displays the Title Page dialog.
Activates the General Tank Data dialog. As mentioned above, data must be provided on this dialog for
every tank analyzed. This information consists of the diameter, the number of courses, the course height,
course thickness, course material, fluid depth, fluid specific gravity, temperature, pressure, external loads,
and the desired code. Details of the General Tank Data dialog are discussed in Section 6.2.
Activates the Roof Specification Parameters dialog. This dialog provides for the input of roof descriptive
parameters. Details of the Roof Specification Parameters are discussed in Section 6.3. The computations
that use this data can be found in API-650 Appendix F, and in the text by Brownell & Young. This dialog is
an optional input, depending on the tank.
Activates the Seismic Data Specifications dialog. This dialog is used to describe the seismic parameters
associated with the tank location. Details of this dialog are discussed in Section 6.4. The computations that
use this data can be found in API-650 Appendix E. This dialog is an optional input, depending on the tank.
Activates the Grillage Review dialog. This dialog is used to specify the grillage parameters. Details of this
dialog can be found in Section 6.5. The specifics of this computation can be found in API-650 Appendix I,
Section I.7. This dialog is an optional input, depending on the tank.
Activates the Nozzle Stiffness dialog. This dialog allows the specification of up to fifteen low nozzles on the
tank. Details of this dialog can be found in Section 6.6. The computations that use this data can be found in
API-650 Appendix P. This dialog is an optional input, depending on the tank.
Activates the Appendix M Cycle Life Data specification. This data is used in the procedures outlined in
API-650 Appendix M to determine the allowed number of “fill-empty” cycles the tank can undergo without a
detailed stress analysis. Details of this dialog can be found in Section 6.11. This dialog is an optional input,
depending on the tank.
Activates the Appendix V External Pressure dialog. This data is used to determine the external pressure
capacity of the tank.
Activates the Shell Settlement Data dialog. This data is used in the procedures outlined in API-653
Appendix B to determine the maximum and allowed out-of-plane settlement of the tank shell. Details of this
dialog can be found in Section 6.7. This dialog is an optional input, depending on the tank.
Activates the API-2000 Venting Data dialog. This data is used to determine the necessary venting for
inbreathing, outbreathing, and fire.
Activates the Tank Sizing/Costing Scratch-pad dialog. This Scratch-pad allows the user to estimate tank
sizes and plate costs for a range of tank dimensions. Details of this dialog are discussed in Section 6.9.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-4 TANK - API 650/653 ANALYSIS-3.10
Launches the computation engine for the Tank Sizing/Costing Scratch-pad dialog. This option is only
active after data has been entered on the Scratch-pad.
Transfers the minimum cost tank (results) from the Scratch-pad, to the General Data dialog. This serves as a
good starting point for a tank design.
As with most software programs, there is an option to save the current state of the input data to a
disk file. With TANK, users can saved the input by using the File menu, or by clicking the
Diskette icon. It is suggested that the input be manually saved frequently during any extended
editing session. Beginning an analysis will also save the data (automatically), but it is always
best to be on the safe side.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-5
The Tank Description Page is intended to provide a means to document, with the input data, any
peculiarities of the tank or any special notes. The Tank Description Page dialog can be
activated by selecting the first option of the Input menu, or by clicking the associated toolbar
icon.
The buffer to store the data for this page is sized for 60 lines of 75 characters. If necessary, this
dialog can be scrolled to view any additional lines. Standard Windows editing functions are
available on this dialog.
Note that the Title Page menu option provides two sub-options. The first displays the title page,
the second replaces the title page contents with a default title page, found in the file TITLE.HED.
The default title page can also be loaded from the associated toolbar icon.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-6 TANK - API 650/653 ANALYSIS-3.10
The General Tank Data dialog allows the user to specify all of the basic characteristics of the
tank under study. This dialog consists of three “tabs”, as shown in Figure 6.3.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-7
The Tank Data tab presents a dialog on which the overall characteristics of the tank are
specified. For each input cell, a descriptive comment defines the expected input. Where
applicable, the expected units display to the right of the input cell. Note that the input for Shell
Course Material is a general field, used as the default for all individual shell courses. The […]
button to the right of the input cell displays a context menu which allows entry into the active
Material Database, or the manual modification of the properties for the specified material. This
context menu displays in Figure 6.4.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-8 TANK - API 650/653 ANALYSIS-3.10
Clicking the Database option from this context menu produces a dialog from which any valid
material can be selected from the active database. (The active database can be selected or
changed via the TOOLS\CONFIGURE menu option.)
Clicking Edit Properties from the context menu displays a dialog where the properties retrieved
from the database can be overridden (modified) for this particular tank.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-9
The material and its properties set here on this tab are used as default values for all of the shell
courses. If necessary, the material can be changed on a course by course basis. This is possible
by using the second tab, Shell Courses of the General Tank Data dialog. This tab presents a
grid where the height, thickness, corrosion allowance, material name, material design stress, and
material test stress can be specified for each shell course.
Note that the design and test stress values are normally acquired from the Material Database, for
the specified material. Initially, all courses acquire the same material, as specified on Tab #1.
However, as necessary, specific shell courses may be assigned a different material, or the material
for specific courses may be manually modified by the user. Right clicking on the Material cell
will display the Material context menu as described above.
For carbon steels from Table 3-2, the program fills in the Sd and St values. For stainless steels,
the value used for Sd is unknown until run-time. Therefore, for stainless materials, the allowable
versus temperature table displays in the right-most grid columns of this dialog. For stainless
materials, the value of Sd (on this dialog) is shown as zero. The actual value used in the
calculations is reported in the output.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-10 TANK - API 650/653 ANALYSIS-3.10
The Wind Details tab is used to define detailed wind parameters specific to ASCE #7. If these
times are not defined, TANK will use the recommended API 650 defaults.
The Anchor Bolt tab is used to define the data necessary for the program to design anchorage, if
necessary. API-650 Section 5.12 defines a number of different cases which must be evaluated
(depending on the tank), and may result in the design of required anchorage.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-11
The Anchor Bolt Diameter and Number of Anchor Bolts fields are optional inputs. The Bolt
Allowable Stress field is no longer used (as of API-650 10th Edition Addendum 3), but is
maintained for compatibility with existing TANK input files.
The entry on this line indicates whether API-650 or API-653 rules should be applied to the
current job file. Select the desired entry from the drop-down list.
API-650 is intended for the design of new tanks, and can be implemented in either design or
analysis modes. API-653 is intended for the analysis of existing tanks, and therefore can only be
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-12 TANK - API 650/653 ANALYSIS-3.10
used in "analysis" mode. (see "Run Objective" on page 6-12) This cell is used to define the roof
type of the tank. The value entered in this cell must be a number from 1 to 4, which corresponds
to the roof types listed below.
Design Method
Enables the user to specify the preferred method of evaluating the shell course thickness
requirements. Use the table below to identify the appropriate entry for this line.
ENTRY MEANING
V The program uses the Variable design method
This entry also determines how (which method) the allowed fluid heights are computed.
Run Objective
Enables the user to specify whether or not the program should analyze the tank based on the
user's input, or design the necessary parameters to satisfy the API code. The setting of this input
field is important because it affects all computations following the shell course thickness
evaluation.
If "D" Design mode is selected subsequent calculations for wind girders, seismic, and internal
pressure will all use the larger of the design or test thicknesses.
If "A" Analyze mode is selected subsequent calculations use the course thicknesses specified by
the user. The computed thicknesses for the design and test cases are reported for information
purposes only. A message to this affect is included in the output report when analyze mode is
selected.
Design Temperature
Enter the desired design temperature in the indicated units. API-650 limits the design temperature
to 200 deg F/ 93 deg C. If the design temperature exceeds this limit, but is less than 500 deg F/
260 deg C then the rules of Appendix M are applied.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-13
Note: Design Temperatures in excess of 500 deg F/ 352 deg C cause a fatal error.
If the value of the design temperature is changed, the program automatically implements a routine
to interpolate the data from API-650 Table P-1. The resulting values of modulus and expansion
coefficient are inserted into the Nozzle dialog.
Enter the desired design pressure in the indicated units. Note, API-650, Appendix F limits the
design pressure to 2.5 psi / 17.2 kPa.
Enter the diameter of the tank. Note, as per API-650, the program assumes the tank diameter is
the centerline diameter of the bottom shell course plates.
Enter the total height of the tank shell. This value should be the sum of the individual course
heights, and is used in the wind load computations.
Enter the height of the design liquid level. This is the height from the tank bottom to the top of
the shell or to the bottom of any overflow device.
Enter the specific gravity of the fluid. Note, this value is used only in the Design case. The
program automatically uses a specific gravity of 1.0 for the Hydrotest case.
Enter the total weight of the attachments and structures on the roof and shell which should be
considered to resist uplift and in the maximum allowed pressure computation.
Enter the distance from the top of the tank shell to the location of the top wind girder. If the top
wind girder is at the top of the shell, this value should be entered as zero. If the top wind girder is
below the top of the tank (i.e. for a walk-way), enter the actual distance.
As per Appendix A.3.4, the joint efficiency should be either 0.85 or 0.70. API-653 Section 2.3.3
also utilizes this value of joint efficiency. No other computations use this value, so the default of
1.0 can be left alone for Variable Point and One Foot API-650 calculations.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-14 TANK - API 650/653 ANALYSIS-3.10
API-653 2nd Edition provides Table 2-1 for weld joint efficiencies if the original E value is
unknown. This table is reproduced below:
Notes:
(a) Full double lap welded.
(b) Full fillet weld with at least 25% intermittent full fillet opposite side:
k = percent of intermittent weld expressed in decimal form.
(c) Single butt-welded joints with a back-up bar were permitted from the years of 1936 to
1940 and 1948 to 1954.
Wind Velocity
Enter the wind velocity acting on the tank. Due consideration should be given to Section 5.9.7.1a.
The standard is a 120 mile per hour (53.6 m/sec) wind, but may be increased to account for
additional tank height, wind gust, internal pressure, or open-top tanks.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-15
Several configuration directives control how the wind pressure is computed and applied to the
tank. These directives are:
Roof Projection in Wind Moment (on page 3-4) - Turns on an off wind loads on the roof.
10% Plus 5psf in Wind Moment (see "10% Plus 5 psf in Wind Moment" on page 3-4) - Which is
the basic wind moment definition as per Section 5.9.7.
Section 5.11 Wind Pressure - Defines the wind pressure to be used for Section 5.11 stability.
This field displays the material name. To properly access a valid material name and its properties,
use the right mouse button and click Database from the "context menu" and the Material
Database Selection screen appears. Alternatively, left click the ... button to display the same
context menu.
When a valid material is selected, its allowable stresses, yield strength, tensile strength, grade,
and group are acquired from the database for subsequent program use.
The data specified here is assumed to pertain to the entire tank. If the material varies over the
shell courses, this data may be specified using the Shell Course Materials dialog.
Enter the number of shell courses in the tank. This entry is used to check the shell course input
and control the shell course generation if necessary.
If the tank will have an annular base ring, enable this checkbox.
This directive is used to specify which wind moment is to be used in the computations of
Appendix F. By default the program will use the moment computed from Section 5.9.7.1 in
Appendix F computations. However, if desired, the wind moment computed from Section 5.11
can be used.
Note that the wind pressure computed according to Section 5.9.7.1 (based on the wind velocity
(on page 6-14)) is used for the wind girder design, the wind pressure according to Section 5.11 is
used for Over Turning Stability. This directive only affects which wind moment is passed into
Appendix F for the allowed pressure in Section F.4.2.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-16 TANK - API 650/653 ANALYSIS-3.10
As per API-653 Section 4.3.3.1, activate this radio button if the shell thickness calculation is for
the entire shell course. This selection uses equation 4.3.3.1.a, which deducts 1 foot from the fluid
height. However, this deduction only occurs if the 1 foot method is in use.
As per API-653 Section 4.3.3.1, activate this radio button if the shell thickness calculation is for a
local area of the shell course. This selection uses equation 4.3.3.1.b, which does not deduct 1 foot
from the fluid height.
The shell course height does not need to be specified for any course after the 1st course, if it is
constant. The program will duplicate the shell course height to all required courses if this cell is
left blank.
Shell Course Thickness
For the current shell course, enter its thickness. If the purpose of this job is to design the shell
course thickness, then enter a "good" starting value (see API-650 5.6.1.1). If this cell is left blank
for the first course, the program will set the thickness according to API-650 Table 5.6.1.1.
Note that the shell course thickness does not need to be specified for any course after the 1st
course, if it is constant. The program will duplicate the shell course thickness to all required
courses if this cell is left blank.
Shell Course Corrosion Allowance, CA
Enter the corrosion allowance to be considered in the thickness evaluations for shell course #n.
Note that the corrosion allowance does not need to be specified for any course after the 1st
course, if it is constant. The program will duplicate the corrosion allowance to all required
courses if this cell is left blank.
Shell Design Stress, Sd
This value represents the allowable design stress, referred to as Sd in the API code. This value is
automatically registered by the program if the material was selected from the database.
If necessary, the value of design allowable stress obtained from the database may be overridden
by entering a different value in this input field.
Note, for stainless steels, this value will be displayed as zero, since a temperature versus
allowable table is used instead.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-17
If necessary, the value of test allowable stress obtained from the database may be overridden by
entering a different value in this input field.
SSD1 through SSD5
These values represent the allowable stress for a stainless steel according to API-650 Appendix S,
Table S-2. Note, these values are used during the computation phase of the solution to determine
the actual Sd value.
For stainless steels, these values will be interpolated during the solution phase. For this reason,
the value of Sd (at the left) is displayed as zero.
If desired, enter the bolt diameter of an existing anchorage. If entered, and the anchorage is
necessary, it will be evaluated using this data.
The program can evaluate a user specified design, or design an anchorage according to API-650
Section 5.12. In order to size the anchor bolts, the thread pitch is necessary. The pitch is the
reciprocal of the parameter known as "threads per inch".
Enter the "threads per inch" in the appropriate units. NOTE, THIS IS A REQUIRED ENTRY,
which will be used in the event the program must design an anchorage. Typical "threads per inch"
for various size UNC bolts are listed below:
0.6250 11
0.7500 10
0.8750 9
1.0000 8
1.1250 7
1.2500 7
1.3750 6
1.5000 6
1.7500 5
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-18 TANK - API 650/653 ANALYSIS-3.10
2.2500 4.5
2.5000 4
2.7500 4
3.0000 4
3.2500 4
3.5000 4
3.7500 4
4.0000 4
Prior to Addendum 3 of the 10th edition of API-650, the bolt allowable stress was required input.
As of this addendum, the bolt allowable is determined for various load cases as specified in
Section 5.12.
This value is therefore no longer used, but is maintained for compatibility with older input files.
Note, if the program redesigns the anchorage, the number of bolts will be a multiple of the bolt
increment specified in the configuration.
Enter the yield stress of the anchor bolts for use in Section 5.12. NOTE, THIS IS A
REQUIRED ENTRY which will be used in the event the program must design an anchorage.
Enter the offset from the mean tank diameter to the anchor bolt circle. This value must be greater
than zero for bolt circles outside the tank.
If this value is left blank, an offset of 0.0 will be used. Note that the program internally multiplies
this value by 2.0 before adding it to the tank diameter value.
Enter the value of the corrosion allowance to be considered when sizing the anchor bolts. Note
that API-650, Section F.7.4 requires a corrosion allowance of at least 0.25 inches.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-19
Wind Kz Paramater
Enter the velocity pressure coefficient as defined by ASCE #7. If left blank the value defaults to
1.04.
Enter the wind speed up factor for hills. This value should be 1.0 (the default) except for those
structures on isolated hills or escarpments.
Wind Kd Paramater
Enter the wind directionality factor. API 650 recommends a value of 0.95 (the default) for this
parameter.
Wind I Paramater
Enter the wind importance factor as defined by ASCE #7. If left blank the value defaults to 1.0.
Enter the wind gust factor as defined by ASCE #7. If left blank the value defaults to 0.85.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-20 TANK - API 650/653 ANALYSIS-3.10
Roof Data
The Roof Data dialog is an optional input. This dialog is used to specify the roof parameters
when necessary. The Roof Data dialog is divided into three tabs, as shown in Figure 6.9.
Whenever a tank has a roof to be design, the top half of this dialog must be filled out. This
section of data defines in general terms the overall geometry of the roof. At this point, a decision
must be made as to whether a simple approximation will be made, or a supported cone roof will
be designed. The approximation requires the specification of the remaining data on the General
Root Specs tab. This data is used in further analysis, such as seismic analysis, wind over turning,
and maximum allowed pressure.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-21
If instead, a supported cone roof is to be designed, then the bottom half of General Root Specs
tab should be left blank. The data necessary for supported cone roof design should be specified
on Supported Cone Root Data tab. This tab, shown in Figure 6.10, displays the parameters
used in the roof design.
The parameters necessary for the proper design of a supported cone roof include: the desired
cross section type for rafters, girders, and columns, the material for the cross sections and roof
plate, and the maximum allowed length for the rafters and girders. The allowed cross sections
vary, depending on the active structural library. The help system provides guidance here, in the
usage of the various structural types, and in the available cross sections.
Note that for the structural and roof plate materials, the […] button may be used to bring up the
context menu which allows selection from the Material Database.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-22 TANK - API 650/653 ANALYSIS-3.10
Providing all of the data shown in Figure 6.10 allows TANK to design a supported cone roof
according to the procedures outlined in the text by Brownell & Young. This includes positioning
the girder rings according to the maximum allowed rafter lengths. If however, alternate
positioning is desired, the design can be forced in a certain direction by specifying data on the
Girder Rings tab.
This grid is used to specify the location of each girder ring, and how many girders make up the
ring. If this information is specified, then the members are sized only, as the number of girder
rings, column rings, and rafter rings is known.
Input Fields
The Roof Data dialog input fields are described below.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-23
Roof Type
This cell is used to define the roof type of the tank. The value entered in this cell should be
selected from the drop down list, which corresponds to the roof types listed below.
For supported cone roofs, the program can design the rafters, columns and girders. For rafter
supported cone roofs, the program can design the rafters. All other roof types are considered
solely for their weight effects on shell.
Enter the angle between the roof and a horizontal plane at the roof-shell junction.
Enter the area resisting the compressive force. For details refer to API-650 Figure F-2.
Enter the nominal thickness of the roof plates. This value should include the corrosion allowance
(see "Roof Plate Corrosion Allowance" on page 6-23) if any.
Enter the corrosion allowance to be considered when determining the weight of the roof plates for
Appendix F and overturning computations. This value will be subtracted from the nominal roof
plate thickness (on page 6-23).
Enter the total weight of the roof plates to be considered in API-650 Appendix E and Appendix F
computations.
Note, TANK will determine the weight of the roof plates internally. If the computed value is
greater than the input value specified here, or a supported cone roof is being designed, the
computed value will be used in subsequent calculations. If the input value is greater, it will be
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-24 TANK - API 650/653 ANALYSIS-3.10
used (unless a supported cone roof is being designed). For supported cone roofs, the computed
roof plate weight is always used.
Enter the total weight of any snow on the roof to be considered in API-650 Appendix E
computations for seismic checks.
Note that if the supported cone roof design procedures are implemented, TANK will determine the
load applied to the roof internally. This value will not be used.
Enter the total weight of the roof framing to be considered in API-650 Appendix E and Appendix
F computations.
Note that if the supported cone roof design procedures are implemented, TANK will determine the
weight of the roof framing internally. This value will not be used.
Enter the percentage of the roof and snow weights that are to be considered as supported by the
shell for API-650 Appendix E checks.
Note that if the "supported cone roof design" procedures are implemented, TANK will determine
the % of weight supported by the shell internally. This value will not be used.
Enter the value to be used in computing the load supported by the roof plates. According to API-
650 5.10.2.1 this value must be at least 20 pounds per square foot.
The dead load of the roof will be computed by the program, and combined with the live load to
determine the total roof load.
Enter the preferred section type for the roof rafters. The roof rafter locations are shown in the
figure below. The specific section types depend on the active structural database. Valid types as a
function of the database are listed below.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-25
For the 1989 AISC library, valid types for this cell are: W, WT, S, C, DC, DI, and P. These
descriptors correspond to the following cross sections from AISC:
For the 1990 Korean library, valid types for this cell are: W, C, and M. These descriptors
correspond to the following cross sections:
For the 1993 UK library, valid types for this cell are: UB, UC, T, and C. These descriptors
correspond to the following cross sections:
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-26 TANK - API 650/653 ANALYSIS-3.10
For the 1991 German library, valid types for this cell are: I, U, and T. These descriptors
correspond to the following cross sections:
For the 1990 Australian library, valid types for this cell are: UB, and UC. These descriptors
correspond to the following cross sections:
For the 1990 South African library, valid types for this cell are: IP, HP, CP, and CT. These
descriptors correspond to the following cross sections:
Enter the preferred section type for the roof girders. The roof girder locations are shown in the
figure below. The specific section types depend on the active structural database. Valid types as a
function of the database are listed below.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-27
For the 1989 AISC library, valid types for this cell are: W, WT, S, C, DC, DI, and P. These
descriptors correspond to the following cross sections from AISC:
For the 1990 Korean library, valid types for this cell are: W, C, and M. These descriptors
correspond to the following cross sections:
For the 1993 UK library, valid types for this cell are: UB, UC, T, and C. These descriptors
correspond to the following cross sections:
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-28 TANK - API 650/653 ANALYSIS-3.10
For the 1991 German library, valid types for this cell are: I, U, and T. These descriptors
correspond to the following cross sections:
For the 1990 Australian library, valid types for this cell are: UB, and UC. These descriptors
correspond to the following cross sections:
For the 1990 South African library, valid types for this cell are: IP, HP, CP, and CT. These
descriptors correspond to the following cross sections
Enter the preferred section type for the roof columns. The roof column locations are shown in the
figure below. The specific section types depend on the active structural database. Valid types as a
function of the database are listed below.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-29
For the 1989 AISC library, valid types for this cell are: W, WT, S, C, DC, DI, and P. These
descriptors correspond to the following cross sections from AISC:
For the 1990 Korean library, valid types for this cell are: W, C, and M. These descriptors
correspond to the following cross sections:
For the 1993 UK library, valid types for this cell are: UB, UC, T, and C. These descriptors
correspond to the following cross sections:
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-30 TANK - API 650/653 ANALYSIS-3.10
For the 1991 German library, valid types for this cell are: I, U, and T. These descriptors
correspond to the following cross sections:
For the 1990 Australian library, valid types for this cell are: UB, and UC. These descriptors
correspond to the following cross sections:
For the 1990 South African library, valid types for this cell are: IP, HP, CP, and CT. These
descriptors correspond to the following cross sections:
This cell allows entry into the Material Database from which a material for the roof plates can
be selected. The Material Database can be entered (activated) by clicking the [...] button.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-31
This cell contains the value used as the allowable design stress for the roof plates. This value is
automatically filled in when the Roof Plate Material is specified.
This cell allows entry into the Material Database from which a material for the structural
members can be selected. The Material Database can be entered activated by clicking the [...]
button.
This cell contains the value used as the allowable design stress for the structural members. This
value is automatically filled in when the Structural Member Material is specified.
Note that for compliance with API-650 Section 3.10.3.4, this value should not exceed 20000 psi
(137895 kpa).
Enter the maximum length allowed for the rafters. This value is used to determine the radii to the
various girder rings. Typical values for this cell are 20.0 to 24.0 feet (6.1 to 7.3 meters).
In the design of the supported cone roof, the roof plates sit on top of the rafters. The rafters are
oriented along radial lines, from the center of the tank. The rafters are arranged in rings around
the tank, where the rafter lengths do not exceed the maximum user specified value. The ends of
the rafters are supported on girders, arranged in concentric circles, where the girder lengths do not
exceed the maximum user specified value. The girders are supported by columns.
Enter the maximum length allowed for the girders. This value is used to determine how many
girders are required for each girder ring. Typical values for this cell are 24.0 to 30.0 feet /7.3 to
9.1 meters.
In the design of the supported cone roof, the roof plates sit on top of the rafters. The rafters are
oriented along radial lines, from the center of the tank. The rafters are arranged in rings around
the tank, where the rafter lengths do not exceed the maximum user specified value. The ends of
the rafters are supported on girders, arranged in concentric circles, where the girder lengths do not
exceed the maximum user specified value. The girders are supported by columns.
Enter the diameter of the center column cap plate if necessary. If this cell is left blank, a value of
zero will be used.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-32 TANK - API 650/653 ANALYSIS-3.10
When the Number of Girder Rings has been specified, the radial distance to each ring must be
defined. In this cell, enter the radial distance from the center of the tank to the current girder ring.
When the Number of Girder Rings has been specified, the number of girders in each ring may
also be specified. These entries are optional, HOWEVER, if the number of girders in any one ring
is specified, then the number of girders in all rings must be also specified.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-33
Seismic Data
The Seismic Data dialog is an optional input. This dialog is used to specify the seismic
(earthquake) parameters when necessary.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-34 TANK - API 650/653 ANALYSIS-3.10
The Seismic Use Group for the tank should be specified by the purchaser. See API-650 Section
E.3.1 for details on the various SUG categories. Valid entries for this field are 1, 2, or 3
(corresponding to SUG groups I, II, and III).
Friction Factor
Specify the friction factor used to determine tank sliding in API-650 Section E.7.6. Note that API
limits the maximum value of this friction factor to 0.4.
Importance Factor
Usually this value is 1.0, unless specified otherwise by the purchaser. API recommends that this
value not exceed 1.25, and that this value (1.25) only be used for emergency services.
Define the Initial Anchorage Type as either Self Anchored or Mechanically Anchored (bolted).
Note, even if a Self Anchored tank is specified, the requirements of the Code may be such that
anchor bolts are required. In this instance, the program will design bolting.
Earthquake Type
Define the Earthquake Type as either Site Specific or Mapped. For details on Mapped and Site
Specific earthquakes refer to API-650 Sections E.4.2 and E.4.3.
Site Class
Define the Seismic Site Class according to Section E.4.6. Valid choices here are "A" through
"F", where "F" represents soils that require site-specific evaluations.
Define the Spectral Acceleration Adjustment Coefficient (K). This coefficient is used to adjust
the spectral acceleration from 5% to 0.5% damping. The value of this coefficient defaults to 1.5
if not specified by the user.
Define the Scaling Factor (Q). This is the scaling factor from MCE (the maximum considered
earthquake) to the design level spectral accelerations. The value of Q is 2/3 for ASCE #7.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-35
Define the Transitional Period (TL). TLis the regional-dependent transition period for longer
period ground motion, in seconds. Unless otherwise specified, TL shall be taken as the mapped
value found in ASCE #7.
Define SP - the design level peak ground acceleration parameter for sites not addressed by ASCE
methods.
Define SDS - the design, 5% damped, spectral response acceleration parameter at short periods
(T = 0.2 seconds) based on ASCE 7 methods, %g.
Define Sa0* - the 5% damped, design spectral response acceleration parameter at zero period
based on site-specific procedures, %g.
Define Sa* - the 5% damped, design spectral response acceleration parameter at any period based
on site-specific procedures, %g.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-36 TANK - API 650/653 ANALYSIS-3.10
Grillage Data
In some cases, a tank must rest on a lattice of grillage. When this is necessary, the data on the
Grillage dialog can be specified. This will allow the software to compute either the grillage
spacing, or the required nominal thickness of the bottom plate.
The data acquired from this dialog is used in the computations of API-650 Appendix I, Section 7.
Enter the value of the Elastic Modulus to be used for the bottom plate.
Enter the corrosion allowance to be added to the bottom plate thickness. If left blank, this value
defaults to zero.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-37
Enter the thickness of the bottom plate. This value is may be left blank if the grillage spacing is
entered. In this case, the program computes the required thickness of the bottom plate. As stated
in API-650 5.4.1, bottom plates should have a minimum thickness of 0.25 inches (6.35mm).
Note this value should correspond to the value entered on the Seismic Data Spreadsheet. If a
value is entered here, the user is prompted to see if the same value should also be used on the
Seismic Data Spreadsheet.
Optionally enter the maximum allowed spacing (center-to- center between adjacent or radial
grillage members. If this value is entered, then the bottom plate thickness should be left blank so
the program can compute it.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-38 TANK - API 650/653 ANALYSIS-3.10
Nozzle Flexibilities
TANK allows the specification of up to fifteen low tank nozzles. The data specification can
include external piping loads, if available from a pipe stress analysis.
The data acquired from this dialog is used to implement the rules of API-650 Appendix P.
Note that whenever the tank temperature value from the General Tank Data (on page 6-6)
dialog is changed, the values of Elastic Modulus and Expansion Coefficient are automatically
updated. These values are obtained by interpolating the data provided in Table P-1 of API-650.
If the check-box for Apply PVP-1279 is enabled, TANK will use an alternate method to compute
the nozzle stiffnesses. This alternate procedure is detailed in PVP-1279 and is valid for smaller
tanks.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-39
Nozzle Designation
Defines a descriptive tag or number of the current nozzle. This cell is restricted to 4
CHARACTERS in length, and can contain letters and/or digits. Example entries for this cell are
listed below:
NZ1 NA0A
NZ2 PGLG
NZ3
Enter the height of the nozzle centerline above the bottom plate.
Delta Temperature
Enter the difference between the normal operating temperature and the installation temperature.
Enter the modulus of elasticity. These values should be taken from API-650 Table P-1,
reproduced below:
Note that the value of elastic modulus is automatically defined by the program when the user
changes the design temperature on the general spreadsheet. This value can be changed by the user
if necessary.
If the bottom shell course is specified as Stainless Steel, then the modulus value for Table P-1 is
not used. Instead, the modulus value is obtained from Table S-6 and are reproduced below:
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-40 TANK - API 650/653 ANALYSIS-3.10
200. 27.4E6
300. 26.6E6
400. 26.1E6
500. 25.2E6
Expansion Coefficient
Enter the value of the thermal expansion coefficient. These values should be taken from API-650
Table P-1and are reproduced below:
The value of expansion coefficient is automatically defined by the program (using internal,
English, units) when the user changes the design temperature on the general spreadsheet. This
value can be changed by the user if necessary.
This entry indicates where the nozzle reinforcement is located. This entry is used to interpolate
among the charts in API-650 Appendix P. If reinforcing on the shell is indicated, Appendix P
makes the following assumptions:
- the reinforcing pad thickness is equal to the shell thickness
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-41
These assumptions are implicit in the curves presented in Appendix P and are automatically
considered by the program.
This cell is used to define the thickness of the nozzle reinforcing pad if it exists, and if it should
be considered in the computations. Note that API-650 Appendix P offers no guidance on how
reinforcing pads should be handled.
If a pad thickness is specified here, it will be used to increase the thickness of the tank shell in all
Appendix P computations.
Nozzle Weight
Enter the weight of this nozzle. The value entered here will be used in all weight computations
involving the shell.
Enter the value of any applied radial force, acting on the nozzle. The value entered here will be
used in plotting the interaction diagram of Appendix P.
Enter the value of any applied external circumferential moment acting on the nozzle. The value
entered here will be used in plotting the interaction diagram of Appendix P.
Enter the value of any applied external longitudinal moment acting on the nozzle. The value
entered here will be used in plotting the interaction diagram of Appendix P.
Use PVP-1279
Enabling this option allows TANK to utilize an alternate method to compute nozzle stiffnesses.
This alternate method is based on PVP (Pressure Vessel and Piping) paper 1279 - Stiffness
Coefficients for Nozzles in API-650 Tanks, by Lengsfeld, Bardia, Taagepera, Hathaitham,
LaBounty, and Lengsfeld.
This alternate method is based on the finite element analysis of a number of tanks, resulting in
alternate curves and equations for the determination of tank nozzle stiffnesses.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-42 TANK - API 650/653 ANALYSIS-3.10
The outside diameter of the nozzle reinforcing pad, if any. This value is used to determine the
vertical distance from the nozzle centerline to the point where the tank bottom has no influence
on nozzle stiffness.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-43
The Shell Settlement dialog is used to define the measured settlement of up to 40 points around
the tank shell circumference.
The data from this dialog is used to implement the requirements of API-653, Appendix B.
Enter the value of the Elastic Modulus to be used in the computation of the allowed shell
settlement, in API-653 Section B.3.2. If this value is left blank a default of 29.5E6 psi / 203000
MPa will be used.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-44 TANK - API 650/653 ANALYSIS-3.10
Enter the distance (in degrees) between adjacent settlement measurement points. This value must
be less than 45 degrees. API-653 Appendix B.1.3 requires at least eight points around the
circumference of the tank. This limits the entry in this field to a maximum of 45 degrees.
Additional data points will reduce the magnitude of this angle.
Note that the code limits the spacing between these measurement points (around the
circumference of the tank) to 32 feet / 9.8 m. Prior to API-653 2nd Edition Addendum 2, this
limit was 30 feet / 9.1m.
Note also that too many points may lead to an over conservative determination of the out-of-plane
deflection limit. Addendum 3 to the 9th Edition of API-653 suggests computing the deflection
limit using points spaced at approximately 30 foot / 9.1m intervals. Additional details on this
subject can be found in "Out of Plane Settlement of Cylindrical Tanks" by Erdmann and Yeigh,
Hydrocarbon Engineering, May 1999 and the text by Phil Meyers, Above Ground Storage Tanks.
TANK performs all computations using all of the specified measurement points. If the number of
measurement points is so great as to cause the spacing to fall below 15 feet / 4.6m, use every
other point when generating the input.
Settlement Elevations
Enter the elevation of the shell bottom at this measurement point on the circumference of the
tank.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-45
The API-653 Service Measurement Data dialogs allow the user to specify additional
measurement data, obtained from tank inspections. This measurement data can be used to
implement the shell and bottom checks discussed in API-653 Sections 4.3.3.1, 4.3.3.2, and
4.4.7.1. The data for the service measurement analysis is presented in a series of tabbed dialogs,
each discussed in the following subsections.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-46 TANK - API 650/653 ANALYSIS-3.10
All values to be entered on this dialog are defined, and include the corresponding code
nomenclature (from earlier editions of the code). This dialog is included to maintain backwards
compatibility with previous versions of TANK and earlier editions of the code.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-47
If the joint efficiency left blank, the value specified on the General Data dialog will be used.
Similarly, if the L location is left blank, the fluid height will be determined from the bottom of the
course. If the t1 or t2 values are left blank, they default to the user-specified thickness on the
General Data dialog.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-48 TANK - API 650/653 ANALYSIS-3.10
As per API-653 Section 4.4.7.1, enter the value of the minimum remaining thickness from the
bottom side corrosion, after repairs.
As per API-653 Section 4.4.7.1, enter the value of the minimum remaining thickness from
internal corrosion, after repairs.
As per API-653 Section 2.4.7.1, enter the value of the anticipated in-service period of operation
(normally 10 years).
As per API-653 Section 2.4.7.1, enter the value of the maximum internal pitting rate, on a yearly
basis. If the tank bottom is internally lined (per API RP 652), this value should be specified as
0.0.
As per API-653 Section 2.4.7.1, enter the value of the maximum underside pitting rate, on a
yearly basis. If the tank bottom is cathodically protected (per API RP 651) this value should be
specified as 0.0.
In this cell, enter the average depth of the internal pitting of the bottom plates. This value is
measured from the original thickness.
In this cell, enter the maximum depth of underside pitting of the bottom plates.
In this cell, enter the average depth of underside pitting of the bottom plates.
In this cell, enter the original thickness of the bottom plates. This value should correspond to the
bottom plate thickness entered on the Seismic Data (on page 6-33) and the Grillage Data (on
page 6-36) dialogs, if they have been specified.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-49
As per API-653 Section 2.4.7.1, enter the value of the average depth of the generally corroded
area, (GCa).
As per API-653 Section 2.4.7.1, enter the value of the maximum rate of general corrosion, on a
yearly basis.
As per API-653 Section 2.4.7.1, enter the value of the maximum depth of internal pitting
remaining in the bottom plates after repairs are completed. Note, this value is measured from the
original thickness.
Maximum rate of corrosion not repaired in top side (StPr). StPr = 0 for coated areas of the
bottom. The expected life of the coating must equal or exceed Or to use StPr = 0.
As per API-653 Section 2.4.7.1, enter the value of the maximum underside pitting rate, on a
yearly basis. If the tank bottom is cathodically protected (per API RP 651) this value should be
specified as 0.0.
In subsequent thickness computations, the fluid height to the design liquid level is measured from
the bottom of "L".
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-50 TANK - API 650/653 ANALYSIS-3.10
This check box is used to indicate whether or not the user specified location L will be used in
subsequent thickness calculations.
Enabled Enabling this box allows the program to use the user specified values of the location of
"L" to be used in determining the height to the maximum design liquid level. When this
box is checked, the height value is computed according to API-653 Section 2.3.3.1.
Disabled Disabling this box causes subsequent computations to ignore the user input values of
the location of "L". The thickness computations use a height value measured from the
bottom of each course, which produces more conservative (thicker) thicknesses.
This check box is used to indicate whether or not the user specified values of individual course
joint efficiencies will be used in subsequent computations.
Enabled Enabling this box allows the program to utilize the individual joint efficiencies for each
course in any subsequent computations. This may be useful if additional inspections and
radiography are performed.
Disabled Disabling this box causes the program to ignore the specified values of individual
course joint efficiencies. Instead, the computations are made using the joint efficiency
specified on the General Tank Data dialog.
This check box is used to indicate whether or not the user specified values of individual course
thicknesses of t1 and t2 should be used in subsequent computations.
Enabled Enabling this box allows the program to perform the thickness checks per API-
653 2.3.3.1. Values of t1 or t2 left blank will assume the thickness specified on
the General Data dialog.
Disabled Disabling this box prevents the program from performing the thickness checks
of API-653 2.3.3.1.
Enter in this cell the original thickness of the bottom shell course. This value is used to determine
the minimum thickness of the annular base plate, as per API-653 Table 2- 3.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-51
The Tank Sizing / Costing Scratch-pad provides the user with a quick way to both size and
price a tank, based on the required volume. This Scratch-pad is a calculation module which
implements the API-650 One-Foot method to determine the required shell thicknesses. The user
may alter the specification data and recompute the size and cost estimates as many times as
necessary. After exiting the Scratch-pad, the user has the option of transferring the diameter,
height, and course thicknesses to the General Tank Data Dialog for subsequent computations.
No other data on the Scratch-pad is saved.
There is a minimum amount of data to be specified by the user. This data consists of the required
tank volume, the fluid specific gravity, the plate allowable stress, the unit cost of plate, and the
height and diameter ranges.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-52 TANK - API 650/653 ANALYSIS-3.10
Once the necessary data has been specified, the Calculate option from the Input menu can be
used to invoke the computations. Alternatively, the Calculator icon can be used. Both of these
options are enabled as soon as data is entered on the Scratch-pad.
The Scratch-pad computes a total of eight tanks - four for a diameter range, and four for a height
range. The results of each range are presented in the list box below the input definition.
For each tank evaluated, the necessary diameter (or height) is presented, as well as the thickness
required for each shell course. The height of the top course is also reported, all other courses
being equal to the specified input value. The results of the costing are presented last, and consist
of the shell weight and cost estimate. The shell weight is based on the computed thicknesses and
the plate density specified in the configuration file. The cost is the product of the unit price and
the plate weight.
If necessary, the input data can be altered, and new estimates obtained. When the desired results
have been achieved, a report can be printed, or the results for the minimum cost tank transferred
to the General Data (see "General Tank Data" on page 6-6) dialog.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-53
Once the Scratch-pad calculations have been performed, the Dynamic Sizing Tool becomes
active. This sizing tool, located to the right of the output display, contains two slider bars.
Moving the slider bars with the mouse changes the corresponding dimension of the tank, as well
as updates the right most column of numerical data in the table.
Required Volume
This cell is used to specify the desired volume of the tank for sizing purposes. The sizing routine
will determine diameters and heights necessary to achieve this volume.
Enter the fluid specific gravity to be used in sizing the tank. Since the tank must be hydrotested,
the minimum value for this entry should be 1.0.
Enter the unit cost of the plate material. This value is used to compute the total material cost of
the various tank shells. The cost is computed by multiplying this value by the total steel volume
in the shell multiplied by the standard weight of steel.
Note that the mass conversion factor is applied to this value to compute the final tank cost. FOR
CONSISTENT APPLICATION, YOU MUST INSURE THAT THE "MASS"
CONVERSION AND THE "DENSITY" CONVERSION BOTH USE THE SAME UNIT.
For example lb. and lb/cu.in. or KG and KG/cu.cm.
Enter the value to be used as the allowable stress for the tank sizing. This value should
correspond to the fluid specific gravity entered above. For example, if the fluid specific gravity is
1.0 (for water in the hydrotest case), then this value should be the TEST allowable stress. If the
fluid specific gravity corresponds to the operating fluid, then this allowable stress should
correspond to the DESIGN case.
This value is used to determine how many full courses are needed to achieve the desired volume.
The top course may be less than the value specified here, since the top course height is used to
exactly match the desired volume.
The values entered here represent the minimum and maximum limits for the tank height. A total
of four (4) heights between these limits will be determined (and the corresponding diameters) to
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-54 TANK - API 650/653 ANALYSIS-3.10
size the tank. For each height/diameter value, the shell plate thicknesses will be determined,
followed by plate weight and cost.
Note that the height range is independent of the diameter range. Four values of height between
the minimum and maximum values are determined. The necessary diameter to achieve the
required volume is then determined, exclusive of the diameter range.
The values entered here represent the minimum and maximum limits for the tank height. A total
of four (4) heights between these limits will be determined (and the corresponding diameters) to
size the tank. For each height/diameter value, the shell plate thicknesses will be determined,
followed by plate weight and cost.
Note that the height range is independent of the diameter range. Four values of height between
the minimum and maximum values are determined. The necessary diameter to achieve the
required volume is then determined, exclusive of the diameter range.
The values entered here represent the minimum and maximum limits for the tank diameter. A
total of four (4) diameters between these limits will be determined (and the corresponding
heights) to size the tank. For each height/diameter value, the shell plate thicknesses will be
determined, followed by plate weight and cost.
Note that the diameter range is independent of the height range. Four values of diameter between
the minimum and maximum values are determined. The necessary height to achieve the required
volume is then determined, exclusive of the height range.
The values entered here represent the minimum and maximum limits for the tank diameter. A
total of four (4) diameters between these limits will be determined (and the corresponding
heights) to size the tank. For each height/diameter value, the shell plate thicknesses will be
determined, followed by plate weight and cost.
Note that the diameter range is independent of the height range. Four values of diameter between
the minimum and maximum values are determined. The necessary height to achieve the required
volume is then determined, exclusive of the height range.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-55
API-2000 Venting
The Venting Data dialog is an optional input. This dialog is used to specify the flow rates for
emptying and filling the tank, as well as the environmental factors, and liquid characteristics.
Emptying Rate
Enter the maximum emptying rate (volume per hour) of liquid from the tank. See API-2000
Section 4.3.2.1.1 for details.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-56 TANK - API 650/653 ANALYSIS-3.10
Filling Rate
Enter the maximum filling rate (volume per hour) of liquid from the tank. See API-2000 Section
4.3.2.2.1 for details.
Boiling Point
Environmental Factor
English Units
Configuration Conductance Insulation F Factor
(BTU/hr ft2 F) Thickness (in)
Bare metal tank --- 0 1.0
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-57
Metric Units
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-58 TANK - API 650/653 ANALYSIS-3.10
The Cycle Life dialog is an optional input. This dialog is used to specify the data necessary to
evaluate the anticipated number of "full - empty" cycles the tank is permitted to cycle through
without a detailed stress analysis.
Enter the difference in filling height between the full level of the tank and the low level of the
tank.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-59
Temperature Difference
Enter the difference between the minimum ambient temperature and the tank's maximum
operating temperature.
Factor B
Enter the foundation factor. This value is:
2.0 for tanks on earth foundations
4.0 for tanks on earth foundations with a concrete ring-wall
Factor C
Enter the factor to account for the radial restraint of the tank's shell-to-bottom junction with
respect to free thermal expansion. The value for C ranges from a minimum of 0.25 to a maximum
of 1.0. The actual design value of C shall be established considering the tank's operating and
warm-up procedure and heat transfer to the subgrade.
Factor K
Enter the stress concentration factor for the bottom plate at the toe of the inside shell-to-bottom
fillet weld.
NOTE: The magnetic particle examination shall be performed on the root pass at every 1/2
inch / 13mm of deposited weld metal while the weld is being made and on the completed weld.
The examination shall be performed before hydrostatic testing.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-60 TANK - API 650/653 ANALYSIS-3.10
External Pressure
The External Pressure dialog is an optional input. This dialog is used to specify the parameters
necessary to evaluate the external pressure capacity of the tank.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 6 TANK Input 6-61
Where fc = 0.4Fy of components considered for the intermediate and bottom stiffeners. However,
fc need not be less than 15,000 psi (103 MPa).
Where fc = 0.6Fy of components considered for the top end stiffener region. However, fc need not
be less than 20,000 psi (140 MPa).
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
6-62 TANK - API 650/653 ANALYSIS-3.10
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
7-1
C H A P T E R 7
In This Chapter
The Error Checker Module......................................... 7-2
Warning & Error Options........................................... 7-4
Completing the Error Check Phase ............................ 7-5
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
7-2 TANK - API 650/653 ANALYSIS-3.10
The normal chain of events requires that the Error Checker validate the input data before the
analysis phase is allowed to begin. The Error Checker is a separate module that is designed to
prevent illegal or illogical data from being passed to the analysis program. The tasks performed
involve checking for negative values where only positive values are allowed, ensuring that the
corrosion allowance does not drive the thickness to zero, as well as API code restrictions.
The Error Checker can produce two types of diagnostic messages, errors and warnings. A
warning message indicates that the program discovered something in the input data that the
analyst should be made aware of.
The program always considers warning messages as acceptable. As long as the analyst agrees
with (or is aware of) the warning message, it can be considered acceptable to the analyst also. If
the analyst disagrees with or is surprised by the warning message, it should be considered an error
and the input modified accordingly.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 7 Error Checking 7-3
The second type of diagnostic message that can be produced is an error message. An error
message indicates a problem with the input severe enough to prevent the analysis from
completing.
When an error is encountered, the analysis phase is prevented from starting. The user must
correct the input to eliminate the error. (Note that the error shown above in Figure 7.2 is an error
for API-650 and a warning for API-653.)
Whenever a warning or error message displays, the user is given several choices as to the next
course of action. These choices are the subject of the next section.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
7-4 TANK - API 650/653 ANALYSIS-3.10
Any time an error or warning displays, the user has several options available to direct the next
course of action. Use the list below to determine the appropriate action to perform.
Prints the last error message displayed in the list box. Error checking will resume once the user clicks
the Continue button below the list box.
Disables the display of warnings and notes and only displays error messages once this button is
activated. After each error message is displayed, error checking will resume only once the user clicks
the Continue button below the list box.
Disables the further display of the current message. This option is useful when a number of identical
errors or warnings will be displayed. In this case, it is not necessary to review each message.
Each time a message displays in the list box, the procedure halts until the user clicks Continue.
This gives the necessary time to review the message. If it is necessary to abort the error check
phase and return to the Main menu, one of two methods can be used. The File\Exit option can
be used as well as the X in the upper right corner of the title bar.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 7 Error Checking 7-5
Once all of the input data has been evaluated, the Error Checker produces a summary report, and
pauses for user interaction.
When the review of this summary is complete, clicking Continue produces a dialog requesting
authorization to build the necessary analysis files. The typical response to this prompt is Yes.
One more click of the Continue button exits the Error Checker and returns control to the Main
menu.
If the summary report shows that errors were found, the analysis files will not be created. The
job can not be analyzed in this condition. The user must return to the input and correct the
problems as reported by the Error Checker.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
8-1
C H A P T E R 8
In This Chapter
Analysis ...................................................................... 8-2
TANK Program Files ................................................. 8-3
Solution Overview...................................................... 8-4
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
8-2 TANK - API 650/653 ANALYSIS-3.10
Analysis
The design or analysis of the tank data occurs in the solution module. This module cannot be
accessed unless the input data has been successfully error checked. Once the solution module has
been launched, the Analysis Monitoring screen displays.
This screen displays the current job name, the major solution steps to the analysis, and which
solution steps are required by the current input data. As each solution step is entered, an asterisk
is placed next to the item to show the current progress. There is no user interaction or input
during the solution phase. The analysis/solution phase consists of implementing the rules and
equations found in the API-650 and API-653 codes. A brief overview of this phase can be found
in the Solution Overview section.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 8 Analysis/Solution Phase 8-3
After successfully completing, the analysis module creates the .TKO file, containing the solution
data in binary format. The TKO file is used by subsequent modules to formulate and generate the
various reports and graphics.
Occasionally users may want to know how an iteration proceeded or the results of an intermediate
computation. The message file (TXT) serves to answer these queries. As important milestones in
the analysis are reached, newly computed data is labeled and written to the message file.
The message file is useful in the event that a fatal error is encountered, and a program abort
occurs. In this instance, a diagnostic message is presented to the user, control is returned to the
Main menu, and no output (TKO) file exists. Since there is no TKO file, entry into the output
processor is not allowed. In this instance, the message file can be very helpful. In addition to
intermediate and partial solution data, some reasons for program aborts may be found in this file.
The message file is a standard ASCII text file which can be viewed with a variety of editors, or
printed to the system printer. The user may also access the message file from the Tools menu.
It is important to note that generation of the message file by the solution module only takes place
if the current configuration allows. Generation of the message file can be controlled from the
Computation Options tab of the configuration module. Refer to the Program Configuration
(on page 3-1) section for additional details.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
8-4 TANK - API 650/653 ANALYSIS-3.10
Solution Overview
The major steps performed in the solution phase are discussed in this section. Users are advised
to refer to codes API-650 and API-653 for additional details.
The first consideration of the program is the wind effect. The specified wind speed is used to
determine the applied wind pressure, the velocity factory, and the overturning moment. These
values are used later in the computations for the wind girders and Appendix F considerations.
The next computation determines the allowable stresses for both the design and test cases. The
material control routine includes considerations for reductions due to temperature from Appendix
M and if necessary Appendix S and API-653 Section 2 requirements. The allowables for each
shell course are determined individually based on the specified course materials.
The solution module then determines the required shell course thicknesses based on the specified
design method, either one-foot, variable point, or Appendix A. The appropriate sections of the
code are implemented using the material properties to determine the thicknesses for each course
for the design and test cases. Each thickness computation is then followed by a check of API-650
Section 5.6.1.1 to insure that the minimum thickness requirements of the code are met. If the
input indicates that the program is to operate in analysis mode to rate an existing tank, the design
and test thicknesses just computed are replaced with the users input thicknesses for subsequent
computations. A note to this effect appears in the output below the thickness table when
required.
Following the shell course thickness determination, the allowed fluid heights are determined.
This procedure involves the use of the same code sections used in the thickness determination,
and in the case of the variable point method is an iterative process.
Once the shell course thicknesses and fluid heights have been determined, the program computes
the shell weight and center of gravity. The weight/c.g. routine compares the computed shell
weight with that specified by the user, and selects the maximum of the two for subsequent
computations in Appendix E.
After the weight and c.g. are computed, the overturning stability according to Section 5.11 is
checked. Next, the wind girder requirements are checked. The number of girders, their section
moduli, and their locations are determined according to API-650 Section 5.9. Wind girder detail
and size is then selected from API-650 Table 5-22.
This concludes the general computations performed for each tank input data set. All subsequent
computations are optional depending on user specification.
If the roof data has been specified, the program will now evaluate, analyze, or design the roof.
Roof evaluation involves weight summations, required thicknesses and net areas according to
API-650 Sections 5.10.5 or 5.10.6. The analysis or design of a supported cone roof applies the
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 8 Analysis/Solution Phase 8-5
procedures outlined in Brownell & Young. Following the roof design, the Section 5.10.3 checks
are implemented.
Once the actual roof computations are completed, the API-650 Appendix F requirements are
evaluated.
Also note that the roof weights computed from a design are used in subsequent (seismic)
computations.
The next series of computations which may be performed are the seismic requirements of API-
650 Appendix E. The guidelines of this appendix are applied to the tank in three conditions,
design, test, and empty.
The next series of computations which may be performed are the nozzle flexibility calculations as
outlined in API-650 Appendix P. This appendix also offers guidelines on the maximum allowed
nozzle loads. The program can determine the flexibilities and limiting loads on up to fifteen
nozzles for all three sets of shell course thicknesses (design, test, and user input).
The next series of computations which may be performed are the grillage computations. These
computations conform to the rules of API-650 Appendix I, Section 7.
The next series of computations which may be performed are the settlement limits as set forth in
API-653 Appendix B. These computations use an iterative procedure to determine the optimum
cosine curve which most closely represents the user's measured values of shell settlement. Once
the cosine curve is known, the out-of-plane settlement and out-of-plane deflection can be
determined.
The next series of computations which may be performed are the service/maintenance
computations. These computations are based on API-653 Section 2.
The next series of computations that may be performed are the API-2000 Venting calculations.
After all sizing, roof, and seismic computations have been completed, the evaluation for the
permitted cycle life according to Appendix M, Section M.4 begins.
Following the cycle life calculations, the bolting requirements are checked. This procedure
evaluates each of the load cases defined in Section 5.12 and determines, if necessary, the required
number of bolts and the bolt size. A second pass is then made to determine the governing
condition and to report a single bolt size and quantity, with the corresponding stress for each load
case.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
9-1
C H A P T E R 9
In This Chapter
The Local Graphics Menu.......................................... 9-2
Tank Layout Sketch.................................................... 9-5
Shell Settlement Plots................................................. 9-7
Nozzle Interaction Diagrams...................................... 9-9
Supported Cone Roof Sketches .................................. 9-12
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
9-2 TANK - API 650/653 ANALYSIS-3.10
Once an analysis has been completed, the output options are available. These options include
both text based reports, and graphics. The topic of this chapter is local graphics, that is graphics
produced on the terminal, for subsequent printing or capturing. The available graphics are:
A general tank sketch showing plate layouts and overall dimensions
A pair of nozzle interaction diagrams, used to check the conformance of the nozzle to API-
650 Appendix P.
A sketch of the results of the supported cone roof design.
A plot of the shell settlement and optimum cosine curve results.
Each of these graphics is discussed in the following sections.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 9 Local Graphics Output 9-3
The Local Graphics module can be entered by selecting OUTPUT\LOCAL GRAPHICS, or by selecting
the icon representing an XY plot. If output is not available for the current job, both of these items
are grayed out. Once the local graphics mode has been entered, the Main Menu changes to
reflect the graphics controls. This presents the user with the screen shown in Figure 9.1.
This menu presents options for the tank sketch, shell settlement plotting, nozzle interaction
diagrams, and supported cone roof sketches. In addition to the menu options, the following icons
are also available.
Produces the basic tank sketch.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
9-4 TANK - API 650/653 ANALYSIS-3.10
Exits the graphics processor and return to the text based menu. Use of this option is necessary
to review text based reports, or modify the input data.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 9 Local Graphics Output 9-5
Enables the generation of an overall tank sketch with a number of optional details.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
9-6 TANK - API 650/653 ANALYSIS-3.10
The tank sketch is useful to get an overall representation of the size of the tank.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 9 Local Graphics Output 9-7
Produces XY type plots detailing the shell settlement evaluation according to API-653 Appendix
B. The Settlement menu provides options to plot the settlement measurements, the optimum
cosine curve, the out-of-plane deflection, as well as an option to spline the data. Splining the data
smooths the curves and makes better presentations.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
9-8 TANK - API 650/653 ANALYSIS-3.10
Note that the settlement plot uses two Y axes. The far left Y axis is for the out-of-plane deflection
curve. The Y axis closest to the curves is for the measured and optimum cosine curves. These
axes and their associated curves are shown in different colors for better visualization.
The settlement plot positions the curves on an X axis showing the relative angular position around
the tank circumference from the point of maximum settlement. The settlement plot also includes
a secondary X axis which shows the location of the actual measurement points.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 9 Local Graphics Output 9-9
The nozzle plots construct the nozzle interaction diagrams of API-650 Appendix P, necessary to
determine if a nozzle is overloaded. The Nozzle Plot menu provides options to select which
nozzle to plot (out of a possible 15), which interaction diagram to plot - either longitudinal or
circumferential, and which thickness to use - either design, test, or user entered.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
9-10 TANK - API 650/653 ANALYSIS-3.10
The resulting sketches also plot the interaction point, as an asterisk. The location of this point is
plotted on the interaction diagram using the input values of applied piping loads. If the piping
loads are not specified, the interaction point plots at the origin.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 9 Local Graphics Output 9-11
For the nozzle to meet the criteria of API-650 Appendix P, the interaction point must plot inside
the diagram.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
9-12 TANK - API 650/653 ANALYSIS-3.10
If a supported cone roof has been designed by the program, the resulting design can be shown
graphically. These roof sketches are not shown to scale, they are provided for information
purposes only.
Besides the basic roof sketch, defining the roof nomenclature, structural cross section sizes,
lengths, and quantities can be noted on the sketch A typical roof sketch, showing cross section
sizes displays in Figure 9.10.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 9 Local Graphics Output 9-13
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
10-1
C H A P T E R 1 0
In This Chapter
Output Overview ........................................................ 10-2
Output Report Discussions......................................... 10-4
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
10-2 TANK - API 650/653 ANALYSIS-3.10
Output Overview
Most of the time spent reviewing the results of a TANK analysis will be in reviewing tabular
reports. These reports are organized in the same manner as the input data is, by topic.
When the analysis phase completes, the Output Report menu displays. This menu lists the
available reports.
Each item in the above menu produces a different report. Multiple reports can be selected using
the [Ctrl] key in combination with a left mouse click. (Items can be de-selected in the same
manner). The first report selected will be presented in the viewing pane on the right side of the
window. Once a report (or multiple reports) has been selected, the View Report menu option
and tool bar icon are activated. The tool bar icons on this menu perform the functions defined in
the following paragraphs.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 10 Output Report Generation 10-3
Enables users to specify the starting page number when printing reports.
This option is useful when a second print session is required it is necessary
that page numbers start where the first report ended.
Select the reports for review, by using [Ctrl] and a left mouse click. Use the Arrow buttons to
move between and review the selected reports. When the interactive review on the screen is
complete, the reports may be printed (assuming the review showed no problems), by clicking the
printer icon.
Sends the selected reports to Microsoft Word. Once in Word, users can make
formatting changes. From the File menu, click Save As to save the Word
document. When finished, control can be transferred back to the output
processor by using OUTPUT\CLOSE MS WORD.
NOTE: When sending reports to MS Word, if a file named "header.doc" exists in the
\tank\system directory, its contents will be read and used as a page header when TANK exports the
reports to Word. The intent is that "header.doc" contain company logo and address details.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
10-4 TANK - API 650/653 ANALYSIS-3.10
Chapter 11 includes several example jobs with complete output report listings. Each of these
reports is discussed, in general, in the following sections. Note that a particular report only exists
if the corresponding input was defined by the user, and the report was requested on the previously
discussed control screen.
Each page of output begins with a header. The header contains the user’s name, page number,
job name, date, time, and program version number.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 10 Output Report Generation 10-5
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
10-6 TANK - API 650/653 ANALYSIS-3.10
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 10 Output Report Generation 10-7
Message File
The Message File report contains the contents of the message file generated by the solution
module. The size of this report will vary depending on which solution routines were needed and
how many iterations were necessary to determine the results.
Note that the values reported in the message file are shown in the program's internal units system,
ENGLISH. All other values in all of the other output reports are shown in the units system
specified by the user.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
10-8 TANK - API 650/653 ANALYSIS-3.10
The next section of the report reflects the material properties used, including the wind girder
height reduction factor. For each shell course, the material name, design allowable stress, test
allowable stress, and Appendix M reduction factor are listed.
The next section of the report details the final shell course thicknesses for the design and test
cases. The user-defined shell course thickness are also reported here, as well as the minimum
allowed metal temperature as obtained from API-650 Figure 2-1. The thickness used in
implementing this figure is the maximum of the design and test cases.
For API-653 analysis, the next section of the output contains a table showing the retiring
thickness and remaining corrosion allowance for each course.
The next section of the report details the allowed fluid heights for the design and test cases, as
well as the required fluid height is also shown in the table.
The next section includes the annular base plate thickness and width, the weight of the shell, and
the center of gravity of the shell.
The next section details the results of the "wind overturning stability check", based on API-650
Section 5.11.
The next section of this report details the results of the wind girder computations. This includes
the required section modulus for both the top and intermediate wind girders, as well as the
maximum height of the unstiffened shell. Following this information is a table showing the wind
girder requirements as a result of the transformed section method. For each wind girder required,
the geometry detail and angle size are also reported. If Detail e is required, the b dimension is
also included in the report.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 10 Output Report Generation 10-9
The final section of this report presents a weight summary of the various tank components.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
10-10 TANK - API 650/653 ANALYSIS-3.10
Roof Evaluation
The roof evaluation report details the results of the design or analysis of supported cone roofs,
and the results of the computations made according to the rules of API-650 Appendix F. The
roof report begins with the required thickness and actual weight of the roof plates, and the design
roof load.
If a supported cone roof was designed or analyzed, the resulting structural member sizes and
loads are reported next. This information begins with the number of girder rings, the radius to
each girder ring, and the number and length of the girders in each ring. This report is shown in
the top half of Figure 10.3.
Also shown in Figure 10.3 are the rafter details. This information includes the number of rafters
in each rafter ring, the spacing on the outer girders, the number of rafters resting on the outer
girders, the spacing on the inner girders, the number of rafters resting on the inner girders, and the
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 10 Output Report Generation 10-11
rafter length. Note that at the center of the tank, and at the shell, the number of rafters per girder
is reported as zero.
The next section of the (supported cone roof) report details the rafter and girder sizing
parameters. This information includes the unit load on the member, the selected cross section,
the required section modulus, and the actual section modulus. This information is provided for
each rafter and girder ring, and is illustrated in Figure 10.4.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
10-12 TANK - API 650/653 ANALYSIS-3.10
The next section of the (supported cone roof) report details the column sizing parameters. This
information begins with the column load, height, allowable compressive stress, and required
radius of gyration. This is followed by the selected cross section, the actual compressive stress,
and the actual radii of gyration. This information is shown in Figure 10.5.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 10 Output Report Generation 10-13
Following the column sizing details is the summary of the checks made according to Section
5.10.3. These checks determine the acceptability of the structural elements based on allowable
stresses and unbraced lengths.
Following these checks is a weight summary of the supported cone roof components.
Following the roof design/analysis report, are the results of the Appendix F computations. This
information begins with the uplift force due to internal pressure and the resisting force due to tank
weight.
This information is followed by the maximum design pressure limited by uplift, the maximum
pressure at the roof/shell junction, and the compression ring failure pressure. All pressures are
reported in the user’s units for pressure and in “inches of water”, an API unit.
The last section of the roof report shows the required area of the roof/shell junction as per Section
F.5, and either 5.10.5 or 5.10.6.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
10-14 TANK - API 650/653 ANALYSIS-3.10
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 10 Output Report Generation 10-15
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
10-16 TANK - API 650/653 ANALYSIS-3.10
Settlement Checks
The settlement check report details the results of the computations made according to the rules of
API-653 Appendix B. This report provides the maximum allowed out-of-plane deflection and a
table showing the out-of-plane settlement at each of the measurement points.
This table also includes the settlement measurements, the optimum cosine curve through these
measured points, the out-of-plane settlement, and the out-of-plane deflection.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 10 Output Report Generation 10-17
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
10-18 TANK - API 650/653 ANALYSIS-3.10
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 10 Output Report Generation 10-19
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
10-20 TANK - API 650/653 ANALYSIS-3.10
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
11-1
C H A P T E R 1 1
Chapter 11 Examples
In This Chapter
Example Problem APP_K .......................................... 11-2
Example Problem O_WC........................................... 11-3
Example Problem A_WC........................................... 11-4
Example Problem KOCZWARA ............................... 11-5
Example Problem B&Y.............................................. 11-6
Example Problem SSTEST1 ...................................... 11-7
Example Problem TEST1........................................... 11-8
Example Problem SSC1 ............................................. 11-9
Example Problem APP_P........................................... 11-10
Example Problem EXTERN01 .................................. 11-11
Example Problem SEIS01 .......................................... 11-12
This chapter discusses several example jobs that illustrate the proper definition of input data and
present solutions to some of the examples found in the code.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
11-2 TANK - API 650/653 ANALYSIS-3.10
The example problem illustrating the application of the Variable Point design method for shell
thickness computations according to Appendix K is located at \examples\app_k.doc.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 11 Examples 11-3
The example problem illustrating the shell thickness computations, as defined by the “One Foot”
method, is located at \examples\o_wc.doc.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
11-4 TANK - API 650/653 ANALYSIS-3.10
The example problem illustrating the shell thickness computations, as defined by Appendix A of
API-650, is located at \examples\a_wc.doc.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 11 Examples 11-5
The example problem illustrating the application of the Fourier Series solution to the optimum
cosine curve in the determination of the API-653 Appendix B out-of-plane settlement
computations, (as defined in a paper by Koczwara) is located at \examples\koczwara.doc.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
11-6 TANK - API 650/653 ANALYSIS-3.10
The example problem illustrating the design of supported cone roofs according to the procedures
outlined in Brownell & Young. This particular example is taken from the text "Process
Equipment Design" by Brownell & Young. For more information see the file
\examples\b&y.doc.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 11 Examples 11-7
The example problem illustrating the implementation of the rules in API-650 Appendix S, for
stainless steel tanks, including the necessary modifications for the high temperature sections of
Appendix M, is located at \examples\sstest1.doc.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
11-8 TANK - API 650/653 ANALYSIS-3.10
The example problem illustrating the general computations performed for typical tank is located
at \examples\test1.doc.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 11 Examples 11-9
The example problem illustrating the computations performed for Appendix E, Seismic
Considerations. is located at \examples\ssc1.doc.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
11-10 TANK - API 650/653 ANALYSIS-3.10
The example problem illustrating the computations performed for low tank nozzles according to
Appendix P is located at \examples\app_p.doc.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 11 Examples 11-11
This example problem illustrates the external pressure performed according to Appendix V.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
11-12 TANK - API 650/653 ANALYSIS-3.10
This example problem illustrates the seismic computations performed according to Appendix E.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
12-1
C H A P T E R 1 2
In This Chapter
Main Set ..................................................................... 12-2
Help & Error Processing Set ...................................... 12-3
English Text Set ......................................................... 12-4
API Data Set ............................................................... 12-5
Examples Data Set...................................................... 12-6
This section lists the files distributed with TANK. The lists correspond to the program sets
manipulated by the installation program.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
12-2 TANK - API 650/653 ANALYSIS-3.10
Main Set
APIOUT.EXE - output preprocessor
APISOLV.EXE - solution module
COADEXE.EXE - EXE file scanner
CRCCHK.EXE - CRC check program
MAKEUNIT.EXE - units generation module
MATEDIT.EXE - material database editor
OUTPUT.EXE - output report review processor
TANK.EXE - main program
TKERCK.EXE - error check module
OUTWORD.DLL - support dll
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 12 Appendix A - Program File List 12-3
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
12-4 TANK - API 650/653 ANALYSIS-3.10
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 12 Appendix A - Program File List 12-5
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
12-6 TANK - API 650/653 ANALYSIS-3.10
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
13-1
C H A P T E R 1 3
This section discusses the four standard units sets distributed with TANK. Users may launch the
units generator to create additional sets if necessary.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
13-2 TANK - API 650/653 ANALYSIS-3.10
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
14-1
C H A P T E R 1 4
In This Chapter
* ASTM Standards......................................................14-2
* CSA Standards.........................................................14-3
* National Standards ...................................................14-4
* ISO 630 ....................................................................14-5
* Stainless Steels (Temperature Dependant) ..............14-6
* Unknown For API-653 ............................................14-7
This section discusses the Material Database. When the Material Database is accessed from
the input module the following properties are returned for each material:allowable design stress,
allowable test stress, minimum yield stress, minimum tensile stress, maximum thickness, grade,
and group.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
14-2 TANK - API 650/653 ANALYSIS-3.10
* ASTM Standards
A-283
A-285
A-131,A
A-131,B
A-131,CS
A-36
A-131,EH36
A-573,58
A-573,65
A-573,705
A-516,55
A-516,60
A-516,65
A-516,70
A-662,B
A-662,C
A-537,1
A-537,2
A-633,C
A-633,D
A-678,A
A-678,B
A-737,B
A-841
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 14 Appendix C - List of Materials 14-3
* CSA Standards
G40.21M,260W
G40.21M,300W
G40.21M,350T
G40.21M,350W
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
14-4 TANK - API 650/653 ANALYSIS-3.10
* National Standards
NS,235
NS,250
NS,275
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 14 Appendix C - List of Materials 14-5
* ISO 630
E 275, C
E 275, D
E 355, C
E 355, D
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
14-6 TANK - API 650/653 ANALYSIS-3.10
SS-304
SS-304L
SS-316
SS-316L
SS-317
SS-317L
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 14 Appendix C - List of Materials 14-7
UNKNOWN
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
15-1
C H A P T E R 1 5
Ver. 2.200
ROOF_PROJECTION_IN_WIND_MOMENT= YES 1 1.
10%_PLUS_5_PSF_IN_WIND_MOMENT= YES 2 1.
SHELL_THICK_CONVERG_TOLERANCE= .5000000E-02 3
GENERATE_MESSAGE_FILE= YES 4 1.
COSINE_CURVE_TOLERANCE= .3000000E+00 5
COSINE_CURVE_ITERATION_LIMIT= .1000000E+03 6
WIND_GIRDER_SHELL_THICKNESS= MAX 7 1.
SHELL_SETTLEMENT_METHOD= FOURIER_SERIES 8 1.
CORRODED_NOZZLES= NO 9 0.
653_CORRODED_HYDROTEST_CASE= NO 11 0.
THICKNESS_ROUNDUP_TO_NEAREST= .0000000E+00 13
PLATE_MATERIAL_DENSITY= .2835648E+00 14
MODIFY_FLUID_HEIGHT_BY_PRESSURE= YES 15 1.
ROUND_ANCHOR_BOLTS_BY= .4000+E01 16
WIND_MOMENT_IN_APP_F Sect.3.9.7.1 17 1.
FULL_SHELL_WEIGHT_IN_APP_F YES 18 1.
MATERIAL_FILE= A650_94.MAT 61 1.
UNITS_FILE= ENGLISH.FIL 62 1.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
16-1
C H A P T E R 1 6
In This Chapter
Version 1.10 Changes (6/94) ......................................16-2
Version 1.20 Changes (11/94) ....................................16-3
Version 1.30 Changes (8/95) ......................................16-4
Version 1.31 Changes (2/96) ......................................16-5
Version 1.40 Changes (9/96) ......................................16-6
Version 1.50 Changes (5/97) ......................................16-7
Version 1.51 Changes (9/97) ......................................16-8
Version 1.60 / 2.00 Changes (1/99) ............................16-9
Version 2.10 Changes (5/00) ......................................16-10
Version 2.20 Changes (9/00) ......................................16-11
Version 2.30 Changes (2/02) ......................................16-12
Version 2.40 Changes (7/02) ......................................16-13
Version 2.50 Changes (3/04) ......................................16-14
Version 2.55 Changes (10/05) ....................................16-15
Version 3.00 Changes (11/07) ....................................16-16
Version 3.10 Changes (9/08) ......................................16-17
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
16-2 TANK - API 650/653 ANALYSIS-3.10
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 16 Appendix E - Revision History 16-3
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
16-4 TANK - API 650/653 ANALYSIS-3.10
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 16 Appendix E - Revision History 16-5
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
16-6 TANK - API 650/653 ANALYSIS-3.10
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 16 Appendix E - Revision History 16-7
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
16-8 TANK - API 650/653 ANALYSIS-3.10
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 16 Appendix E - Revision History 16-9
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
16-10 TANK - API 650/653 ANALYSIS-3.10
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 16 Appendix E - Revision History 16-11
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
16-12 TANK - API 650/653 ANALYSIS-3.10
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 16 Appendix E - Revision History 16-13
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
16-14 TANK - API 650/653 ANALYSIS-3.10
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 16 Appendix E - Revision History 16-15
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
16-16 TANK - API 650/653 ANALYSIS-3.10
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Chapter 16 Appendix E - Revision History 16-17
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
17-1
C H A P T E R 1 7
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
1
Index
*
* ASTM Standards • 14-2 API-650 External Pressure Output • 10-20
* CSA Standards • 14-3 API-653 Service Measurement Data • 6-45
* ISO 630 • 14-5 Appendix A - Program File List • 12-1
* National Standards • 14-4 Appendix B - Standard Units Systems • 13-1
* Stainless Steels (Temperature Dependant) • 14- Appendix C - List of Materials • 14-1
6 Appendix D - Default Configuration Directives •
* Unknown For API-653 • 14-7 3-3, 15-1
Appendix E - Revision History • 16-1
1 Appendix F - Selected References • 17-1
10% Plus 5 psf in Wind Moment • 3-4, 6-15 Applied External Circumferential Moment • 6-41
Applied External Longitudinal Moment • 6-41
6 Applied External Radial Force • 6-41
653 Corroded Hydrotest Case • 3-5 Archiving and Reinstalling an Old, Patched
653 Entire Course Evaluation • 6-16 Version • 1-10
653 Local Area Evaluation • 6-16 Average Course Height • 6-53
Average Depth of Generally Corroded Area • 6-
A 49
Allowable Compressive Stress for Bottom Average Depth of Internal Pitting (StPa) • 6-48
Stiffener (Fc) • 6-61 Average Depth of Underside Pitting (UPa) • 6-48
Allowable Compressive Stress for Top Stiffener B
(Fc) • 6-61
allowable stresses • 8-4 batch stream processor • 5-7
Analysis • 8-2 Boiling Point • 6-56
Analysis/Solution Phase • 8-1 Bolt Offset from Mean Tank Diameter • 6-18
anchor bolt • 6-33 Bottom Plate Corrosion Allowance • 6-36
Anchor Bolt Allowable Stress • 6-18 Bottom Plate Thickness • 6-34
Anchor Bolt Corrosion Allowance • 6-18 Bottom Plate Thickness (Tb) • 6-61
Anchor Bolt Database • 3-8 Bottom Post 3rd Edition • 6-45
Anchor Bolt Diameter • 6-17 Bottom Pre 3rd Edition • 6-46
Anchor Bolt Yield Stress • 6-18 Bottom Shell Course Thickness as Constructed •
Angle Between Measurements • 6-44 6-50
Angle Between Roof and Horizontal • 6-23 Build Version Checker • 5-8
Announcing Builds • 1-9 C
Annular Base Ring • 6-15
Anticipated In-Service Period of Operation (Or) Can Builds Be Applied to Any Version? • 1-9
• 6-48 carbon steels • 6-6
API Data Set • 12-5 Center Column Cap Plate Diameter • 6-31
API Design Code • 6-11 Completing the Error Check Phase • 7-5
API-2000 • 6-1 computation control • 3-4
API-2000 Venting • 6-55 Computation Control • 3-4
API-2000 Venting Output • 10-17 configuration • 3-1
API-650 Bolting Report • 10-18 configuration file • 3-1
API-650 Cycle Life Output • 10-19 Corroded Nozzles • 3-4
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
2 Index
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Index 3
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
4 Index
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
Index 5
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete
COADE, Inc.
12777 Jones Rd., Suite 480
Houston, Texas 77070
Phone: (281)890-4566
Fax: (281)890-3301
E-mail: techsupport@coade.com
WWW: www.coade.com
TANK ™
V E R S I O N 3. 1 0
( L A S T R E V I S E D 09 / 08 )
® 1984 - 2009 C O A D E , I N C . , A L L R I G H T S R E S E R V E D.
www.cadfamily.com EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete