Sei sulla pagina 1di 6

ZXDU CSU501B

Centralized Supervision Unit

1
The Centralized Supervision Unit (CSU) is used to monitor and manage the DC
power system and realize the integrated management of the AC power distribution,
DC power distribution, battery, diesel generator, solar charger, and rectifiers.

Product features

04

All in one 3 type user Flexible Professional


design permission Monitoring and Monitoring
Networking and
Management

It supports Customer/ It meets HTTP, It is designed for


smart battery, Maintainer/ FTP, and SNMP ease of
rectifier, solar Administrator. networking installation and
charger, All user type requirements. It maintenance.
generator, ATS have different supports remote
management. permission to access through a
monitoring or set web browser.
parameter.

2
CSU
Centralized Supervision Unit
CSU501B

Hardware Specifications
Input voltage 36VDC ~ 60VDC
Operating temperature range -20°C ~70°C
Operating humidity 5% ~ 95% (non-condensing)
Cooling solution Air coolant.
Installation mode 1U height
Reverse polarity protection Protect for all signal and power inputs
Transferring information to Alarm -> real time
remote monitoring sever Data -> period
Serial communication 2 x RS485 ports; 1 x RS232 port
Storage at site controller 10,000 history data, 10,000 alarms
LCD, dot matrix, 160 x 160 resolution. Able to adjust
Display type
contrast, angle and display Icon, symbol.
Display Accurary ≤ ± 0,5%
Realtime alarm by light, sound ( >60dB at 1m distance)
Alarm management
Communication failure alarm via Web function
• Shunt type
Battery Current sensor
• Measurement range 0 ~ ±200Adc
Temperature sensor
Output signal : DC current• Range: -40 ~ 150℃
(battery/environment)

Indicator

Indicator Status CSU Status


Power indicator Running indicator Alarm indicator

Solid on Flashing Off Normal operation


Solid on Flashing Flashing Alarm
Solid on Solid on or off - Fault

3
CSU
Centralized Supervision Unit
Physical Specifications
Dimensions CSU501B: 41.5mm *132mm * 300mm (H * W * D)
Weight <1.5 Kg (core controller unit < 0.3Kg)
Power consumption 4.5 W
Communication interface RS232/RS485/RJ45
Analog interface 3 interfaces for battery temperature
USB interface 1 USB interface
Dry contact interface SIU board: 8 for output dry contact, 4 for input dry
contact
GMU and GMUE board (Option): 8 for output dry contact,
4 for input dry contact

Safety certification EN60950


EMS IEC 61000
MTBF ≥ 3.2x 10^5 hours (at 250C)

Functions
• Support the remote firmware update
• Support 4 languages (optional)
• Able to extend Input Output by extension modules (customize based on required)
• Able to update CSU without any affect to system operation.
• Ethernet: RJ45 support multiple monitoring network mode: IPv4/IPv6, HTTPs, SNMP
V2/V3
• MIB file is provided to collect information via SNMP protocol
• Smart charge function: fast charge, float charge, equalize charge. Suitable for many
types of Lithium LFP battery (capacity range: 50-300AH)
• Ability of connection, information display, real-time warning and control for all
connected devices
• Equipment able to be monitored:
 Lead acid battery: Monitor each string via current sensor, voltage sensor, temperature
sensor with BMU(optional).
 Air conditioner controller unit, solar unit, wind energy unit via RS485 (optional)
 Indoor ambient temperature
 Smoke, flood, Door alarm

4
CSU
Centralized Supervision Unit
Main control functions

Setup Port By keypad, by connected computer at site, by remotely

Battery charging mode, temperature compensation

Battery charging voltage and limit charging current

Setup parameters Battery maintain: auto/manual

Low voltage disconnect voltage: LLVD1/BLVD/ DC Low

Over output voltage alarm(can be set)

AC input voltage/current, DC output voltage, Load/Battery current,


Remain capacity of battery

Environment in temperature, battery temperature

AC power off, AC low/high voltage alarm

DC high alarm: 45-59.5VDC ( 2 levels)(able to setup)DC low alarm: 43


58VDC ( 2 levels)(able to setup)

Display Battery temperature high alarm: 30 ~ 80 deg C ( 2 levels)(able to setup)


parameters Battery temperature low alarm: -40 ~ 20 deg C ( 2 levels)(able to setup)

Rectifier failure alarm

CB off alarm of load or battery

High temperature alarm of environment /battery

Smoke alarm, door open alarm

Monitor energy consumption

5
CSU
Centralized Supervision Unit

No. 61, Tran Phu Str., Ba Dinh Dist., Ha Noi City.


Tel: +84-(0)24.37342518
Fax: +84-(0)24.38234128
URL: http://postef.com.vn
E-mail: contact@postef.com.vn