Drum Pump Motors DATA SHEET

SP-ODP Series
Model Enclosure Power Watt V.S.D.
SP-ODP O.D.P 115/1/50-60 450 No
SP-ODP-2 O.D.P 230/1/50-60 450 No
Warning: Not Suitable For Pumping Flammable or Combustible Liquids NOTE: V.S.D. = Variable Speed Drive

SP-280P Series
Model Enclosure Power Watt V.S.D.
SP-280P O.D.P (IP44) 115/1/50-60 825 No
SP-280P-V O.D.P (IP44) 115/1/50-60 825 Yes
SP-280P-2 O.D.P (IP44) 230/1/50-60 825 No
SP-280P-2-V O.D.P (IP44) 230/1/50-60 825 Yes
Warning: Not Suitable For Pumping Flammable or Combustible Liquids NOTE: V.S.D. = Variable Speed Drive

SP-ENC Series
Model Enclosure Power Watt V.S.D.
SP-ENC T.E.F.C (IP 54) 115/1/50-60 825 No
SP-ENC-V T.E.F.C (IP 54) 115/1/50-60 825 Yes
SP-ENC-2 T.E.F.C (IP 54) 230/1/50-60 825 No
SP-ENC-2-V T.E.F.C (IP 54) 230/1/50-60 825 Yes
Warning: Not Suitable For Pumping Flammable or Combustible Liquids NOTE: V.S.D. = Variable Speed Drive

SP-400 Series
Model Enclosure Power Watt V.S.D.
SP-400-2 EXP (IP54) 230/1/50-60 550 No
EEx de IIA T6 II2G
See warning at bottom of page. NOTE: V.S.D. = Variable Speed Drive

SP-A2 Series
Model Consumption Max. Inlet Pressure Output
SP-A2 28 CFM@90 psi 100 psi 3/4 hp
13.2 L/sec @ 6.2 bar 6.8 bar 560 w
SP-A2L 28 CFM@90 psi 100 psi 3/4 HP
(trigger lock) 13.2 L/sec.@6.2 bar 6.8 bar 560 W

SP-A1 Series
Model Consumption Max. Inlet Pressure Output
SP-A1 22 CFM@90 psi 100 psi 1/2 hp
10.4 L/sec @ 6.2 bar 6.8 bar 370 w

WARNING: Pumping of flammables or combustible liquids can generate a static electric discharge, causing fire or explosion resulting in injury or death. Read and under-
stand operating instructions before starting this unit. Follow all federal, state and local safety codes including NFPA 30 - NFPA77. Prior to connecting to air supply, install
bond and ground wires and check continuity of each wire. A meter reading of one ohm or less is required for safe liquid transfer. Use only metallic drum, receiving vessel 7
and metallic pump (SP-SS) when pumping flammables. Air motors are not recognized under any current Underwriter’s Laboratory listing program. Consult a qualified
engineer for suitability for use in a hazardous area or on flammables.
PVDF Series DATA SHEET

STANDARDS's PVDF pump tube is engineered for transferring highly concentrated


aggressive liquids. Robust PVDF offers excellent durability and chemical resistance.

Common Applications

Technical Data

NOTE: Additional lengths available upon request.

8
CPVC Series DATA SHEET

STANDARDS's CPVC pump tube is engineered for transferring corrosive chemicals as-
sociated with the water treatment industry. Robust CPVC offers excellent durability and
chemical resistance.

Common Applications

Technical Data

NOTE: Additional lengths available upon request.

9
Stainless Steel Series DATA SHEET

STANDARDS's Stainless pump tube is engineered for transferring flammable and com-
bustible liquids. Robust Stainless Steel 316 offers excellent strength and durability.

Common Applications

Technical Data

Model Tube Assembly Length Shaft Impeller

NOTE: Additional lengths available upon request.

10
Polypropylene Series DATA SHEET

STANDARDS's Polypropylene pump tube is engineered for transferring corrosive


liquids. Robust Polypropylene ensures chemical resistance against light to mildly
aggressive media.

Common Applications

Technical Data

NOTE: Additional lengths available upon request.

11
High Temperature Polypropylene Series DATA SHEET

STANDARDS's Polypropylene (PHT) pump tube is engineered for transferring high tem-
perature corrosive liquids. Robust Polypropylene ensures chemical resistance and excellent
heat deflection against light to mildly aggressive media.

Common Applications

Technical Data

NOTE: Additional lengths available upon request.

12
Motor & Tube Assembly Detail

Optional 1" (25mm) or


3/4" (22mm) barbed
fitting

13
13
Centrifugal Drum Pump Accessories

FUME BARRIERS/ADAPTORS -- Polypropylene or Stainless Steel


PART NUMBER: BARREL ADAPTER DESCRIPTION
9015 Barrel Adapter - Polypropylene 2" O.D. (51mm)
9002 Barrel Adapter - Stainless 316 2" O.D. (51mm)
PART NUMBER: FUME BARRIER DESCRIPTION
9018 Fume Barrier - Polypropylene 2" (51mm), Viton Seal
9019 Fume Barrier - Stainless 316 2" (51mm), Viton Seal

INTAKE STRAINERS -- PVDF, Polypropylene or Stainless Steel


PART NUMBER: DESCRIPTION
9011 Polypropylene Mesh - .78"x .078" (19.8 x 2mm)
9012 Stainless 316 Mesh - .78"x .078" (19.8 x 2mm)
9043 PVDF - .78"x .078" (19.8 x 2mm)

HAND NOZZLES -- Aluminum, PVDF, Stainless or Polypropylene


PART NUMBER: DISPENSING NOZZLE DESCRIPTION
9017 Polypropylene - 1" O.D. (25 mm) - hose barb intake
9026 Stainless 316 - 1" O.D. (25 mm) - hose barb intake
9028 PVDF - 1" O.D. (25 mm) - hose barb intake
9030 Aluminum Hand Dispensing Nozzle, 1” (25 mm)

WALL BRACKETS -- Recommended for pump storage


PART NUMBER: DESCRIPTION
9006 Wall Storage Bracket

TRANSFER HOSE
PART NUMBER: TRANSFER HOSE DESCRIPTION
9029 Clear PVC 1" I.D. x 1.25" O.D. (28 mm x 31 mm)
Max operating pressure: 30 psi (2 bar)
9032 Clear braided PVC 1" I.D. x 1.25" O.D. (28 mm x 31 mm)
Max operating pressure: 130 psi (8.9 bar)

Quick Disconnect -- Polypropylene


PART NUMBER: QUICK DISCONNECT DESCRIPTION
125A100C Polypropylene - 1.25" thread x 1" barb (28 mm x 25mm)

14
SP-700SR High Viscosity Series
DATA SHEET
The SP-700SR pumps are engineered specifically for transferring viscous materials from drums and tanks commonly
found in the industrial marketplace. The progressive cavity design deliverers a continuous, smooth flow of material
with little product degradation. Maximum viscosity is 25,000 cps (mPAS).

Common Applications Motor Drives


• Polymers • Oil & Greases
• Resins • Paints
• Adhesives • Varnishes

SP-280 Series
Technical Data
Design: Progressive Cavity / Positive Displacement
Max. Viscosity: 25,000cps (mPAS)
Pump Intake: 2” /50mm
Discharge Port: 1.5” / 38mm hose barb, optional 1.25” /32mm
Stator Materials: Teflon, Viton or Buna-N
SP-ENC Series
Mechanical Seal: SiC/Viton/SiC
Immersion Lengths: 27” (700mm)
39” (1000mm)
47” (1200mm)
Please add 6” (150mm) to the Immersion
length of pump for the 752 series pumps.
Wetted Material: Tube & Rotor Assembly: 316 Stainless Steel
Stator Material: Teflon, Viton, or Buna
Motor Drives: SP-280P, SP-ENC, SP-400-2, SP-A2 Series. SP-400 Series
Consult chart for viscosity ratings.
Fittings: Large Type Acme Thread design enables
operator to disassemble pump quickly for
cleaning, maintenance, and inspection.
Max Flow Rate: 17GPM / 64 LPM
Max Pressure: 174 psi / 12 bar
SP-A2 Series
Benefits
• Easy Maintenance
• Threaded Components
• Interchangeable Motors Drives
• Continuous Flow
• Low Shearing Properties

Discharge Fitting
Warning: When pumping flammable or combustible
liquids pump tube must be used in conjunction with
an explosion proof motor.

15
SP-700DD High Viscosity Series DATA SHEET

The SP-700DD pumps are engineered specifically for transferring viscous materials from drums and tanks commonly
found in the Industrial marketplace. The progressive cavity design delivers continuous flow of material with little
product degradation. Maximum viscosity is 100,000 cps (mPAS).
Motor Drives

Common Applications
• Polymers • Oil & Greases
• Resins • Paints
• Adhesives • Varnishes
Pneumatic

Technical Data Electric

Design: Progressive Cavity /Positive Displacement


Max. Viscosity: 100,000cps (mPAS)
Pump Intake: 2” /50mm
Discharge Port: 1.5” / 38mm hose barb, optional 1.25”/32mm
Stator Materials: Teflon, Viton or Buna-N
Immersion Lengths: 27” (700mm)
39” (1000mm)
47” (1200mm)
Please add 6” (150mm) to the Immersion
length of pump for the 752 series pumps.
Mechanical Seal: SiC/Viton/SiC
Wetted Material: Tube & Rotor Assembly: 316 Stainless Steel
Stator Material: Teflon, Viton, or Buna
Motor Drives: Pneumatic or electric motors are available in 50 & 60 Hz,
230, 380, 415 & 460v
Fittings: Large Type Acme Thread design enables
operator to disassemble pump quickly for
cleaning, maintenance, and inspection.
Mounting Flange B14/C140-160
Max Flow Rate: 17GPM / 64 LPM
Max Pressure: 174 psi / 12 bar

Benefits
• Easy Maintenance
• Threaded Components
• Continuous Flow
• Low Shearing Properties

Discharge Fitting
Warning: When pumping flammable or combustible
liquids pump tube must be used in conjunction with
an explosion proof motor.

16
SP-700DD Pump Motors DATA SHEET

Industrial Electric Motors 230–380–415–460v/3/50–60Hz


Model HP KW RPM Enclosure Frame Flange Shipping Wt.
LBS (Kg)

SP-500 0.75 ,55 750–900 TEFC (IP55) 90LC B14/C140 40 (18)


SP-510 1 ,75 750–900 TEFC (IP55) 100LC B14/C160 52 (24)
SP-520 1.5 1,1 750–900 TEFC (IP55) 100LC B14/C160 58 (25)

Industrial Pneumatic Motors


Model HP kW RPM Air Consumption Frame Air Conn. Shipping Wt.
Inch ( mm) LBS ( Kg)

SP-A4 2 1,5 300–900 80 CFM @ 100 psi IEC#72/D71 1/4” (6.35) 12 (5)
37 L/Sec @ 7 Bar
SP-A6 4 3,0 300–900 130 CFM @ 100 psi IEC#72/D80 1/2” (12.7) 24 (11)
65 L/Sec @ 7 Bar
SP-A8 5 3,7 300–900 170 CFM @ 100 psi IEC#72/D90 1/2” (12.7) 26 (12)
80 L/Sec @ 7 Bar

NOTE: Optimal pneumatic motor speed is 900 RPM.

17
Performance Curves

750 RPM 50Hz Operation 900 RPM 60 Hz Operation &


Pneumatic Motors
751 Series Pumps 751 Series Pumps
Pressure — PSI (BAR)

Pressure — PSI (BAR)


90 (6) 90 (6)
80 (5) 80 (5)
70 (4) 70 (4)
60 (3.5) D C B A 60 (3.5) D C B A
50 (3) 50 (3)
40 (2) 40 (2)
30 (1.5) 30 (1.5)
20 (1) 20 (1)
10 (.5) 10 (.5)
0 0 0 0
0 1 (4) 2 (8) 3 (11) 4 (15) 5 (19) 6 (23) 0 1 (4) 2(8) 3 (11) 4 (15) 5 (19) 6 (23) 7 (26) 8 (30)
Flow Rate — GPM (LPM) Flow Rate — GPM (LPM)
Curve Viscosity HP KW Curve Viscosity HP KW
(cps) (cps)
A 1+ .5 ,37 A 1+ .5 ,37
B 10,000+ 1 ,75 B 10,000+ 1 ,75
C 20,000+ 1 1,2 C 20,000+ 1 1,2
D 30,000+ 1.5 1,2 D 30,000+ 1.5 1,2

752 Series Pumps 752 Series Pumps


Pressure — PSI (BAR)

180 (12.5) 180 (12.5)


Pressure — PSI (BAR)

160 (11) 160 (11)


140 (9.5) 140 (9.5)
120 (8) D C B A 120 (8) D C B A
100 (7) 100 (7)
80 (5) 80 (5)
60 (3.5) 60 (3.5)
40 (3) 40 (3)
20 (1.5) 20 (1.5)
0 0 0 0
0 1 (4) 2 (8) 3 (11) 4(15) 5 (19) 6 (23) 0 1 (4) 2(8) 3 (11) 4 (15) 5 (19) 6 (23) 7 (26) 8 (30)
Flow Rate — GPM (LPM) Flow Rate — GPM (LPM)
Curve Viscosity HP KW Curve Viscosity HP KW
(cps) (cps)
A 1+ .5 ,37 A 1+ .5 ,37
B 10,000+ 1 ,75 B 10,000+ 1 ,75
C 20,000+ 1 1,2 C 20,000+ 1 1,2
D 30,000+ 1.5 1,2 D 30,000+ 1.5 1,2

1851 Series Pumps 1851 Series Pumps


Pressure — PSI (BAR)

90 (6) 90 (6)
Pressure — PSI (BAR)

80 (5) 80 (5)
70 (4) 70 (4)
60 (3.5) D C B A 60 (3.5) D C B A
50 (3) 50 (3)
40 (2) 40 (2)
30 (1.5) 30 (1.5)
20 (1) 20 (1)
10 (.5) 10 (.5)
0 0 0 0
0 2 (8) 4(15) 6 (23) 8 (30) 10 (38) 12 (45) 14 (53) 0 2 (8) 4 (15) 6 (23) 8 (30) 10 (38) 12 (45) 14 (53) 16 (61) 17(64) 18 (68)
Flow Rate — GPM (LPM) Flow Rate — GPM (LPM)
Curve Viscosity HP KW Curve Viscosity HP KW
(cps) (cps)
A 1+ .5 ,37 A 1+ .5 ,37
B 10,000+ 1 ,75 B 10,000+ 1 ,75
C 20,000+ 1 1,2 C 20,000+ 1 1,2
D 30,000+ 1.5 1,2 D 30,000+ 1.5 1,2

NOTE: Accuracy of performance curves may vary +/- 10% based on specific applications.
18
Progressive Cavity Drum Pump Accessories

DISCHARGE HOSE CLAMP


PART NUMBER: DESCRIPTION
9038 Malleable iron two bolt clamp. Gripping ridges, reinforced lugs.
Hose size from 1-48/64” to 2-3/64” (44.50 mm to 27 mm). Torge
Value:27 ft.lbs. (3.75 Kg/m) for proper attachment.

RYCO HYDRAULIC OIL TRANSFER HOSE


Recommended For: High pressure hydraulic oil lines. Tube: Black, oil resistant synthetic rubber.
(Nitrile). Reinforcement: One braid of high tensile steel wire. Cover: Black, oil and abrasion resis-
tant synthetic rubber. Flame Resistance: Meets Flame Resistant Designation “GL” Germanischer
Lloyd. Meets Flame Resistant Designation “U.S. MSHA” of the US Department of Labour, Mine
Safety and Health Administration.
Nom. ID Nom. OD Bend Radius Vacuum Weight Temp Range
DIN/in/Dash mm mm in/mm kg/m F˚/C˚
40 /1.5 /-24 50,5 500 27/685.8 1,59 -30 to 220/-34 to 104

Max Dynamic WP Max Static WP Min Burst Pressure


BAR/PSI BAR/PSI BAR/PSI
725/50 970/67 2900/200

PART NUMBER: 9039

PUMP HANGER FOR SP-700DD SERIES


PART NUMBER: DESCRIPTION
743 Hangar, DD Series

QUICK DISCONNECT
PART NUMBER: QUICK DISCONNECT DESCRIPTION
150DSS/150ESS 1.5” ( 38 mm), SS316 Cam Lever Couplings,
BUNA N gaskets, Max. pressure: 150 psi ( 10 BAR).

19
Batch Control System (Low Viscosity) DATA SHEET

STANDARD’S Batch Control System (BCS) is engineered to control, measure and dispense preset volumes of liquid from
drums, IBC‘s, plating tanks or any large storage vessel. The BCS‘s can be used in an industry where batching, chemical
packaging or dilution is required to be accurate and efficient. Simply dial in the desired volume, press ENTER & the BCS
delivers a preset volume of liquid from drums & tanks virtually hands-free.

Features
• Measure flow rate and volume
• Turbine Paddle Wheel Design
• Multiple languages
• Measures: gallons, liters, cubic meters, milliliters, imperial gallons
• Re settable Totalizer
• +/- .05 % accuracy of reading

Common Applications
• Chemical Packaging • Adding Water Treament Chemicals
• Adding Chemistry To Plating Tanks • Chemical Delivery

Technical Specifications

Available Wetted Parts Polypropylene & PVDF


Motor Drive Open Drip Proof (IP44) or TEFC (IP55)
(110v or 230v)
Discharge Fitting 1” (25mm) Hose Barb
Pumping Principle Centrifugal
Flow Capacity 25 GPM (95 LPM)
Maximum Viscosity 300 cps / mPAS
Paddle Wheel Materials PVDF & Ceramic
Immersion Length 27” (700mm), 39” (1000mm), 47” (1200mm)
60” (1500mm), 72” (1800mm)

20
Batch Control System (High Viscosity) DATA SHEET

STANDARD’S Batch Control System (BCS) is engineered for high precision dosing and filling operations involv-
ing viscous materials. This Batch Control System is constructed with robust materials and a choice of motor
drives, therefore offering versatility and safety for the most challenging applications. Simply dial in desired volume,
press enter, and the BCS delivers a preset volume of material from drums and tanks – virtually hands-free.

Features
• Measure flow rate and volume
• Oval gear design
• Multiple languages
• Measures: gallons, liters, cubic meters, milliliters, imperial gallons
• Re settable Totalizer
• +/- .05 % accuracy of reading
Oval Gear Design

Common Applications
• Polymers • Oils • Varnishes
• Paints • Resins • Petroleum Products

Technical Specifications
9” (228mm)

Model Numbers 7310 – TEFC Motor (110v)


7311 – TEFC Motor (230v)
7312 – ODP Motor (110v)
7313 – ODP Motor (230v)
Wetted Parts 316SS / Viton / Aluminum
Motor Drive Open Drip Proof (IP44) or TEFC (IP55)
Intake/Discharge 2” (50mm) / 1 ½” (38mm) Hose Barb
57” (1446mm)

Pump Seal Mechanical – SiC/Viton/SiC


Pumping Principle Progressive Cavity – Positive Displacment
12” (305mm) Max. Discharge Pressure 87 psi (6 bar)
Flow Range 2.6 GPM (9.8 LPM) – 15 GPM (56 LPM)
39” (1000mm)

System Weight 44 Lbs (20 Kg)


Immersion Length 39” (1000mm)
Maximum Viscosity 25,000 cps / mPAS
Measuring Principle Oval Gear Positive Displacement Meter
Maximum Particle Size 1/4” (6mm)

2” (50mm)

21
Flow Meters Industrial Series DATA SHEET

DIGITAL TURBINE FLOW METERS (PADDLE WHEEL)


STANDARD’S Turbine Flow Meters address a broad scope of applications rang-
ing from inert solutions to aggressive chemicals. These meters utilize a proven
paddle wheel design and are available in a variety of sizes and materials. The
meters are designed with the “¼ Lock & Turn System” enabling operators to move
a single totalizer to several flow chambers. Meters are available in three configura-
tions: Kits for Drum Pumps, Barb Connections, or Permanent Installation.

Common Applications Features


• Pump Measurement • Measure flow rate and volume
• Gravity Feed Applications From Tanks • 9v Lithium battery

• System Monitoring • Multiple languages


• Measures: gallons, liters, cubic meters,
• Adding Chemistry to Plating Tanks
milliliters, imperial gallons
• Chemical Packaging
• Re-settable totalizer +/– .05 % accuracy.
• Blending Agricultural Products
• ½” (15mm) - 2” (50mm)
• Adding Colors and Fragrances
• Available materials: PP, PVDF, SS & CPVC

DIGITAL POSITIVE DISPLACEMENT FLOW METERS (OVAL GEAR)


STANDARD’S positive displacement flow meters are suit- Common Applications
able for measuring a broad scope of materials ranging from
water-like liquid to viscous materials. The meter utilizes • Pump Measurement
proven oval gears technology to accurately measure flow • Filling Applications
rate and volume dispensed.The meter housing is available
in Aluminum or Stainless Steel and the Oval gears are avail- • Viscous Materials
able in PPS or Stainless. These meters are equipped with the
1/4 Lock & Turn design enabling operators to move a single
controller to several flow chambers.
Features
• Measure flow rate and volume
• Multiple languages
• Measures: gallons, liters, cubic meters,
milliliters, imperial gallons
• Re settable Totalizer
• +/– .05 % accuracy
• FNPT Port Connections range from
½” (15mm) - 2” (50mm)
• Available in Stainless or Aluminum

22
23
Industrial Pumps & Metering Systems Sanitary Pumps & Metering Systems

Copyright © 2007 STANDARD PUMP, INC. and its licensors. All rights reserved.

Potrebbero piacerti anche