Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
2 POLE
SAFETY
DISCONNECT
To Starter Solenoid and Starter - See Cummins Schematic 99000203 and 99000114
Brown Red
1
1A 2 3
CB1 Fault Reset
10 Amp 1CR
10CR1
(Control)
Hydraulic Oil Temp.
4
R
1CR1 Hydraulic Oil Temp. Fault
2CR1 2CR
White
5
3CR
Hydraulic Oil Level
6
R
3CR1 Hydraulic Oil Level Fault
4CR1 4CR
1CR2 1TD
3CR2
Brn/Blk Blue
16
Red Green Main Console Rod Stacking Area Secondary Console Helper Platform
E-Stop Button 6CR
25 26 E-Stop Button E-Stop Button E-Stop Button
White Black
Neutral Switch 22
6CR3
6CR2 Load Sense Safety 2-way Solenoid
Brown R
6CR2
E-Stop Activated
9 10
CB2
Mast Lights 8CR
15 Amp
(Lower Lts.) Yellow White
11 50W
50W Lower Lights 50W
50W
Black
Console Lights
8
Fault Horn
2CR2 Black
White
Black 4CR2
White
7CR1
Black Yellow
Alarm Button
Black White 28
Main Winch Wraps
Black White 7CR
R
Main Winch Second Layer
Red Red Main Hoist
27 14
CB4
5 Amp White
10CR2 V+ V+
(Accessories) Head
Head RPM Input A Output
Indicator Common Proximity Sensor
Common Green
To Diesel To Diesel
ECM Keyed Ignition Circuit
Input Key Switch
Yellow
12 13 15
10CR
6CR1 1TD1
Brown
Atlas Copco
3001 - U Deck Electrical Schematic
Cummins Tier 3 Pilot Operated
SBC3760012778
July 2007
Legend:
CB - Circuit Breaker NOTE: Branch Circuit Wiring is #14 AWG
WeatherPak Connectors are Used for 3001 Mast Wiring