Sei sulla pagina 1di 4

Hot Press New Siemens 30-06-2020 / I/O Table

Symbol Address Comment


Start_button I3.0 Auto Mode.
Stop_button I3.1 Auto Mode.
Start_Flag M0.0 Start_Flag
Stop_Flag M0.1 Stop_Flag
Pause_Flag M0.2 Pause_Flag
Start_flag_Loader M0.3 Start_flag_Loader
Stop_Flag_Loader M0.4 Stop_Flag_Loader
Ready_Flag_Loader M0.5 Ready_Flag_Loader
Start_Flag_Pusher M0.6 Start_Flag_Pusher
Stop_Flag_Pusher M0.7 Stop_Flag_Pusher
Ready_Flag_Pusher M1.0 Ready_Flag_Pusher
Start_Flag_Hot_Press M1.1 Start_Flag_Hot_Press
Stop_Flag_Hot_Press M1.2 Stop_Flag_Hot_Press
Ready_Flag_Hot_Press M1.3 Ready_Flag_Hot_Press
Start_Flag_delivery M1.4 Start_Flag_delivery
Stop_Flag_Delivery M1.5 Stop_Flag_Delivery
Ready_Flag_Delivery M1.6 Ready_Flag_Delivery
Cake_sensor_1 I0.2 Detects Cake
Cake_sensor_2 I0.3 Detects Cake
Pusher_Sensor I0.4 Detects Pusher's presence
Plate_sensor_1 I0.5 For Plate direction
Plate_sensor_2 I0.6 For Plate direction
Plate_sensor_3 I0.7 For Plate direction
Plate_sensor_4 I1.0 For Plate direction
Plate_position_up M1.7 Plate_position_up
Plate_position_Down M2.0 Plate_position_Down
Plate_up_Ready M2.1 Plate_up_Ready
Plate_down_ready M2.2 Plate_down_ready
Main_Pusher_Forward I1.1 Plate Pusher status
Main_Pusher_Reverse I1.2 Plate Pusher status
Hot_press_Up I1.3 Hot Press Position
Hot_Press_Down I1.4 Hot Press Position
Retainer_In I1.5 Retainer position
Retainer_out I1.6 Retainer position
Delevery_lift_Up I1.7 Delivery Lift Status
Delivery_Lift_Down I2.1 Delivery Lift Status
Hydraulic_Pressure_1 I2.2 Hydraulic pressure switch low
Hydraulic_Pressure_2 I2.3 Hydraulic pressure switch mid
Hydraulic_Pressure_3 I2.4 Hydraulic pressure switch high
Total_Plate_counter_fla M2.3 Total_Plate_counter
Loader_cycle_com_flag M2.4 Loader_cycle_com_flag
cake_in_tray_flag M2.5 cake_in_tray_flag
Cake_full_Flag M2.6 Cake full Flag
Loader_engaged M2.7
Pusher_engaged M3.0
Retainer_in_engaged M3.1
Hot_press_engaged M3.2
Retainer_out_engaged M3.3
Delevery_Rack_Engaged M3.4
Loader_Delay M3.5
Hotpress_delay M3.6
M3.7

1/4
Hot Press New Siemens 30-06-2020 / I/O Table

Symbol Address Comment


Loader_Coil_Up Q0.0 Loader_Coil_Up
Loader_Coil_Down Q0.1 Loader_Coil_Down
Pusher_Coil_forward Q0.2 Pusher_Coil_forward
Pusher_Coil_Reverse Q0.3 Pusher_Coil_Reverse
Retainer_in_coil_up Q0.4 Retainer_in_coil_up
Retainer_in_coil_down Q0.5 Retainer_in_coil_down
Hot_press_up Q0.6 Hot_press_up
Hot_press_down Q0.7 Hot_press_down
Retainer_out_coil_up Q1.0 Retainer_out_coil_up
Reatiner_out_coil_down Q1.1 Reatiner_out_coil_down
Unloader_coil_up Q1.2 Unloader_coil_up
Unloader_coil_down Q1.3 Unloader_coil_down
Cake_full_Counter C3
Total_Cake_counter C0
odd_cakke_counter C1
even_cake_counter C2

Loader_process_start M13.0

2/4
Hot Press New Siemens 30-06-2020 / POU Symbols

Symbol Address Comment


Loader SBR0 SUBROUTINE COMMENTS
Pusher SBR1 SUBROUTINE COMMENTS
Hot_press SBR2 SUBROUTINE COMMENTS
HSC_INIT SBR3
interrupt INT0 INTERRUPT ROUTINE COMMENTS
MAIN OB1 PROGRAM COMMENTS

3/4
Hot Press New Siemens 30-06-2020 / PID0_SYM

Symbol Address Comment


PID0_Low_Alarm VD116 Low Alarm Limit
PID0_High_Alarm VD112 High Alarm Limit
PID0_D_Counter VW80
PID0_D_Time VD24 Derivative Time
PID0_I_Time VD20 Integral Time
PID0_SampleTime VD16 Sample Time (To modify, rerun the PID Wizard)
PID0_Gain VD12 Loop Gain
PID0_Output VD8 Calculated, Normalized Loop Output
PID0_SP VD4 Normalized Process Setpoint
PID0_PV VD0 Normalized Process Variable
PID0_Table VB0 Loop Table Starting address for PID 0

4/4