Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
AUTHORITY ENGINEER:
PROJECT TITLE:
Widening to Double lane with Paved Shoulder from Km. 0.000 to Km. 41.055
(Chandili to Boriguma) of NH-63.
Rev.: R0
DOCUMENT/FILE NO: NH-63/DES/CAL/DRAIN-01 No. of Sheets: 3
Date:21/07/2017
FOR APPROVAL
OF AUTHORITY
ENGINEER
FOR APPROVAL OF FOR APPROVAL OF PROOF
DESIGN DIRECTOR CONSULTANT
DESIGN OF DRAIN
DESIGN OF UTILITY CHAMBER FOR 0.30m HEIGHT ABOVE GL
o
Angle of Internal Friction of Backfill Soil 30.00
Cohesion c = 0.00 t/m^2
o
Angle of Wall friction 20.00
o
Batter of Stem wall with horizontal 90.00
o
Inclination of Backfill with horizontal 0.00
Equiv. Ht. of backfill for Live load surcharge heq = 1.200 m (On heel side)
Equiv. Ht. of backfill for Live load surcharge htoe = 0.000 m (Toe side)
Coeff. of Friction between soil & concrete 0.500 tan
Design Costants:
m = 10 ; k = 0.217 ; j = 0.928 ; Q Normal = 0.672
Q Seismic = 1.008
Clear Cover to reinforcement of Footing & Earth Faces of Stem = 50 mm
Clear Cover to reinforcement on other faces of Stem = 50 mm
Widening to Double lane with Paved Shoulder from Km. 0.000 to Km. 41.055 (Chandili to Boriguma) of NH-63
Page # 1 - 1 of 3.
DESIGN OF DRAIN
4.0 Design of Components:
1.2 At base:
Provide 8mm + 0mm bars @ 200mm c/c on earth face. Ast = 252 mm^2 > 120
Provide 10mm + 0mm bars @ 200mm c/c on other face. Ast = 393 mm^2 > 60
As no vertical load is coming on the median wall, considering the same effect as base of wall at the face of bottome slab.
Widening to Double lane with Paved Shoulder from Km. 0.000 to Km. 41.055 (Chandili to Boriguma) of NH-63
Page # 2 - 2 of 3.
DESIGN OF DRAIN
DESIGN OF DECK SLAB
1.1 DATA INPUT
SR NO DESCRIPTION UNIT VALUE m = 10
1 Out to out distance m 1.50 k = 0.294
2 Thickness of deck slab m 0.125 j = 0.902
Q = 1.330
Density of concrete t/m3 2.5
Grage of concrete MPa 30
Permissible stress in steel(σst) Mpa 240 (IRC‐21:2000,cl 303.2)
Permissible stress in concrete( σcbc) Mpa 10.00 (IRC‐21:2000,cl 303.1)
0.125
All dimensions are in m.
1.2 LOAD CALCULATIONS
1) Dead load calculation
1.3 DESIGN OF SLAB
Final Design moment from Staad Analysis :
d reqd at Span = SQRT((0.228515625*10000000)/(1.33*1000))
= 101.45 mm < 125 Hence O.K.
Ast reqd at Span = ((0.228515625*10000000)/(240*0.902*75))
= 140.75 mm2
1.4 SUMMARY
Moments Ast reqd Area of Ast prov
Sr. No. Type Dia acing (In m
(In t.m) (In mm2) steel (In mm2)
1 Mid span slab
a)Span moments 0.23 140.75 12 150 753.98 753.98 O.K.
Widening to Double lane with Paved Shoulder from Km. 0.000 to Km. 41.055 (Chandili to Boriguma) of NH-63 - 3 of 3.