No Project Title/Student Project Overview Scope of Project Expected Outcome Budget /Lab
(Hardware/Software)
Involved

Hardware: Hardware:

1. This project will cover the 1) Magnetic coil RM 100


hardware and software
system of Magnetic 2) Hall effect sensor RM 50
Induction using hall effect 1. A hardware system which is
sensors. capable of generate the 3) Other electronic RM 120
magnetic field that can components
2. The hardware development Research Grant
consists of magnetic coils, detect by the hall effect
4) SK40B
Magnetic Induction Tomography transmitter and receiver sensor
1 Research Grant
Fundamental Study of (MIT) is among the best growing circuit and also the 5) ICSP programmer
Magnetic Induction System technology in tomography microcontroller. 2. Graphical user interface Research Grant
Using Hall Effect Sensors application because of several using VB as a tool to capture 6) AC-DC adapter
Application advantages. But the research on 3. The software part consist of and store the value capture 7) USB- serial converter Research Grant
the hall effect sensor GUI development which by the hall effect sensor
No. of Student : 2 persons applications in this field is still capable communicate, Software:
low. capture and store the data 3. Analysis of the performance
generated by the hall effect 1. VB Bioinstrumentation
for both hardware and the
sensor from the hardware Lab
part software
2. MPLAB IDE
Bioinstrumentation
4. The software part also Lab
involved in Development of
suitable algorithm for image Total Cost: RM270
reconstruction

An analysis of several types of


2 In Magnetic Induction
magnetic coil properties such
Tomography (MIT) application,
Fundamental Study and as number of turns, types of Bioinstrumentation
the needs of having the best Software:
analysis of magnetic coil wire, diameter and etc in Lab
spec of magnetic coil are very
properties in Magnetic 1. This project consist only generating the best
Induction Tomography important since this is among FEMM software
FEMM software application. performance of a magnetic
the factors that will provide the
induction system for a given
No. of Student : 1 person best image reconstruction of the
measurement distance.
object that is going to be
PPK MEKATRONIK UniMAP

scanned.

1. This project consist


only ANSYS/ other
Fundamental Study and related software
modeling of magnetic field application.
using FEM FEM is among the method that
3 are use in magnetic field 2. The student has to do Software: Bioinstrumentation
No. of Student : 1 person A FEM model for a given
modeling and analysis. It is the study on the
magnetic field properties or
capable of providing magnetic fundamental theory of ANSYS software or Mechanical Design
Co-supervisor : En. Khairul equation
field strength properties for magnetic field. other related software Lab
Salleh analysis.
3. Then analysis of the
certain given
magnetic field
parameters are done.

Hardware:
1. This project covers 1) Magnetic coil RM 100
both hardware and
software systems with 2) Hall Effect sensor RM 50
the application of hall 1. A system which
effect sensors capable of generating 3) Other electronic
RM 120
magnetic field components
2. The student has to strength up to certain Research Grant
develop the system given distance 4) SK40B
Fundamental study of which consist of
MFL is among the current 5) ICSP programmer Research Grant
4 Magnetic Flux Leakage
magnetic coil, 2. A system which is
(MFL) Diagnosis System application in oil and gas pipe
transmitter and capable of detecting 6) AC-DC adapter Research Grant
diagnosis system in Malaysia
No. of Student : 1 person receiver circuit and the MFL up to certain
and also in the world. It applies Research Grant
also the given distance 7) USB- serial
the flux leakage properties for
microcontroller. converter
the crack detection inside the Bioinstrumentation
3. Analysis of the
metal pipe. 8) Gauss meter Lab
3. The hall effect sensor capability of the
will detect the MFL system to detect
Software: Bioinstrumentation
strength and will crack on the metal
Lab
determine whether block
3. VB
there is a crack or not
Bioinstrumentation
on the scanned metal 4. MPLAB IDE Lab
block.
Total Cost: RM270
PPK MEKATRONIK UniMAP

Hardware:

1) Magnetic coil RM 100

2) Hall Effect sensor RM 50


1. The student have to
1. A system which 3) Other electronic
study the suitable RM 120
capable of generating components
spec for the PETG for
magnetic field Research Grant
a certain suitable 4) SK40B
strength that can
depth of the signal
Fundamental study of low penetrate human Research Grant
cost Pulsed Electromagnetic penetration to the 5) ICSP programmer
body up to certain
5 Therapy Generator (PETG) Pulsed electromagnetic therapy human body
given distance and 6) AC-DC adapter Research Grant
has been proved of capable in
with the frequency
No. of Student : 1 person helping the patient of stroke, 2. Development of the Research Grant
that is not harm the 7) USB- serial
migraine, cancer, arthritis and basic system which
human body converter
several others. consist of magnetic Bioinstrumentation
coil, transmitter, 8) Gauss meter Lab
2. An analysis of the
microcontroller and
PETG performance
other related circuits. Software:
whether it is suitable
or not for human
3. Analysis of the 5. VB Bioinstrumentation
application
system performance Lab
6. MPLAB IDE
Bioinstrumentation
Lab

Total Cost: RM270