Sei sulla pagina 1di 5

Technical Data Sheet

Compressor model GLY12RRa


Voltage 115-127V 60Hz ~1
Refrigerant R134a
APPLICATION COMPRESSOR MOTOR
Application High-Medium Back Pressure Displacement 0,65 in³ Nominal Power 3/8 hp
Refrigerant R134a Diameter 1,00 in Voltage/Frequency 115-127V 60Hz
Evaporating Temp. -13,0 ºF to 50,0 ºF Stroke 0,83 in Voltage range 98-140 V
Expansion Capillar/Valve Net Weight 24,56 lb Type CSIR
Comp. Cooling Fan cooled Oil type ISO VG 32 ESTER Phase number 1 PH
Max. ambient temp. 109,4 ºF Oil charge 21,36 in³ Locked Rotor Amps (LRA) 36,00 A
Compatible refriger. R1234yf Max. Cont. Current (MCC) 8,20 A
Main W. resist. at 77ºF 1,27 Ω
Start W. resist. at 77ºF 8,47 Ω

NOMINAL PERFORMANCE APPROVALS


ASHRAE CECOMAF
Cooling Capacity 4.143 BTU/h 3.462 BTU/h
COP 2,20 W/W 1,90 W/W
EER 7,50 BTU/Wh 6,51 BTU/Wh
Input Power 552 W 534 W
Current 6,01 A 5,87 A

TEST CYCLE CONDITIONS


ASHRAE CECOMAF
HMBP (D) HMBP (C)
Evaporating temp. (Te) 45 ºF 41 ºF
Condensing temp. (Tc) 131 ºF 131 ºF
Liquid temp. (Tliq.) 115 ºF 131 ºF
Ambient temp. (Tamb.) 95 ºF 90 ºF
Suction temp. (Tsuction) 95 ºF 90 ºF
Voltage/Frequency 115 V 60 Hz 115 V 60 Hz

ELECTRICAL COMPONENTS
Starting capacitor 170 μF 160 V
Relay Option 1
Reference 2014 184.
Pick-Up 18,70 A
Drop-Out 15,60 A
Protector Option 1
Reference T0260
Current 22,00 A
Time check 7,5-14 seg
Disc temp. (Open/Close) 221,00 / 125,60 ºF

Made by Huayi for Danfoss Technical Data Sheet GLY12RRa Printed on 26/10/17 1/5
Technical Data Sheet
ASHRAE CECOMAF
Tc Te Cooling Consumption Current COP EER Tc Te Cooling Consumption Current COP EER

°F °F Capacity W A W/W BTU/Wh °F °F Capacity W A W/W BTU/Wh

BTU/h BTU/h

104 -13 1.083 260 4,16 1,22 4,17 104 -13 1.003 261 4,16 1,13 3,86
104 -4 1.457 296 4,34 1,45 4,93 104 -4 1.354 297 4,34 1,34 4,58
104 5 1.910 332 4,54 1,69 5,75 104 5 1.776 334 4,55 1,56 5,34
104 14 2.443 370 4,76 1,94 6,61 104 14 2.270 372 4,77 1,79 6,13
104 23 3.056 409 5,00 2,19 7,48 104 23 2.836 411 5,01 2,02 6,93
104 32 3.748 449 5,26 2,45 8,35 104 32 3.475 451 5,28 2,26 7,74
104 41 4.520 490 5,54 2,71 9,23 104 41 4.185 493 5,57 2,49 8,53
104 45 4.885 508 5,68 2,82 9,62 104 45 4.520 511 5,70 2,59 8,88
104 50 5.371 532 5,85 2,96 10,10 104 50 4.967 535 5,88 2,72 9,32

113 -13 1.000 261 4,16 1,12 3,83 113 -13 922 262 4,17 1,03 3,53
113 -4 1.348 299 4,35 1,32 4,51 113 -4 1.245 300 4,36 1,22 4,17
113 5 1.776 337 4,57 1,54 5,26 113 5 1.641 339 4,58 1,42 4,86
113 14 2.284 377 4,80 1,77 6,05 113 14 2.109 379 4,81 1,63 5,59
113 23 2.871 418 5,06 2,01 6,86 113 23 2.649 421 5,07 1,85 6,33
113 32 3.537 460 5,34 2,25 7,69 113 32 3.260 463 5,36 2,06 7,07
113 41 4.284 503 5,64 2,49 8,51 113 41 3.944 507 5,67 2,28 7,82
113 45 4.637 523 5,79 2,60 8,87 113 45 4.267 526 5,81 2,38 8,15
113 50 5.110 548 5,98 2,74 9,33 113 50 4.699 551 6,00 2,50 8,57

122 -13 917 262 4,17 1,03 3,50 122 -13 840 263 4,17 0,93 3,20
122 -4 1.239 302 4,37 1,20 4,11 122 -4 1.137 303 4,38 1,10 3,77
122 5 1.642 343 4,60 1,40 4,79 122 5 1.506 345 4,61 1,28 4,39
122 14 2.124 385 4,84 1,62 5,52 122 14 1.947 387 4,86 1,48 5,06
122 23 2.686 428 5,12 1,84 6,28 122 23 2.461 430 5,13 1,68 5,75
122 32 3.327 472 5,42 2,07 7,05 122 32 3.046 475 5,44 1,88 6,45
122 41 4.048 517 5,74 2,29 7,83 122 41 3.703 520 5,77 2,09 7,15
122 45 4.390 537 5,90 2,39 8,17 122 45 4.015 541 5,92 2,18 7,46
122 50 4.848 563 6,10 2,52 8,60 122 50 4.432 567 6,13 2,29 7,85

131 -13 833 263 4,17 0,93 3,17 131 -13 758 264 4,18 0,84 2,88
131 -4 1.131 305 4,39 1,09 3,71 131 -4 1.029 307 4,39 0,98 3,37
131 5 1.508 348 4,63 1,27 4,33 131 5 1.372 350 4,64 1,15 3,94
131 14 1.964 392 4,89 1,47 5,01 131 14 1.786 394 4,90 1,33 4,55
131 23 2.500 437 5,18 1,68 5,72 131 23 2.273 440 5,20 1,51 5,19
131 32 3.116 483 5,50 1,89 6,45 131 32 2.831 486 5,52 1,71 5,85
131 41 3.811 531 5,85 2,10 7,18 131 41 3.462 534 5,87 1,90 6,51
131 45 4.143 552 6,01 2,20 7,50 131 45 3.762 556 6,04 1,98 6,80
131 50 4.586 579 6,23 2,32 7,92 131 50 4.164 583 6,26 2,09 7,18

140 -13 750 264 4,17 0,83 2,84 140 -13 677 265 4,18 0,75 2,56
140 -4 1.022 308 4,40 0,97 3,32 140 -4 921 310 4,41 0,87 2,99
140 5 1.373 353 4,66 1,14 3,89 140 5 1.237 355 4,67 1,02 3,50
140 14 1.804 399 4,94 1,32 4,52 140 14 1.625 402 4,95 1,19 4,07
140 23 2.315 447 5,24 1,52 5,18 140 23 2.085 449 5,26 1,36 4,66
140 32 2.905 495 5,58 1,72 5,87 140 32 2.617 498 5,60 1,54 5,28
140 41 3.575 545 5,95 1,92 6,57 140 41 3.221 548 5,98 1,72 5,91
140 45 3.895 567 6,13 2,01 6,87 140 45 3.510 570 6,15 1,80 6,18
140 50 4.325 595 6,35 2,13 7,27 140 50 3.897 599 6,39 1,91 6,54

149 -13 667 265 4,18 0,74 2,52 149 -13 595 266 4,19 0,65 2,24
149 -4 913 311 4,42 0,86 2,93 149 -4 812 313 4,43 0,76 2,61
149 5 1.239 358 4,69 1,01 3,46 149 5 1.102 360 4,70 0,90 3,07
149 14 1.645 407 4,98 1,19 4,04 149 14 1.463 409 5,00 1,05 3,60
149 23 2.130 456 5,31 1,37 4,67 149 23 1.897 459 5,33 1,21 4,15
149 32 2.695 507 5,67 1,56 5,32 149 32 2.402 510 5,69 1,38 4,74
149 41 3.339 558 6,06 1,75 5,98 149 41 2.980 562 6,09 1,55 5,33
149 45 3.648 581 6,24 1,84 6,28 149 45 3.257 585 6,27 1,63 5,59
149 50 4.063 611 6,49 1,95 6,65 149 50 3.629 615 6,52 1,73 5,93

Made by Huayi for Danfoss Technical Data Sheet GLY12RRa Printed on 26/10/17 2/5
Technical Data Sheet
EN12900
X Cooling Capacity (W) Consumption (W) Current (A) Mass Flow (kg/h)
1 1.527,4481298953 367,0290419211 4,5996397278 25,099361797102
2 52,1520154278 4,9761162073 0,0328713728 0,9628569894512
3 -13,0521499625 2,4023632435 0,0184917362 -0,068080703996237
4 0,4148045486 0,0261624363 0,0005949833 0,012013607615422
5 -0,3282271731 0,0878730167 0,0006985246 -0,00054012145678484

Equation x1 + x2Te + x3Tc + x4Te2 + x5TeTc

Made by Huayi for Danfoss Technical Data Sheet GLY12RRa Printed on 26/10/17 3/5
Technical Data Sheet
COMPRESSOR DIMENSIONS DESIGNATION INTERNAL DIAM.
1 Suction 0,32 in
2 Service 0,32 in
3 Discharge 0,26 in

WIRING DIAGRAMS AND ELECTRICAL ASSEMBLY


CSIR CONNECTION (L, P ranges)

Made by Huayi for Danfoss Technical Data Sheet GLY12RRa Printed on 26/10/17 4/5
Technical Data Sheet
FIXINGS

SILENT BLOCKS (MOUNTING ACCESSORIES)

STANDARD
Ø0.63 holes (6.69x2.76 net) Ø0.75 holes (6.50x4.00 net) Ø0.63 holes (6.69x2.76 net)

SOA
SOA R134a HMBP