Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
4. The ECP outputs discretes for CLEAR (CLR), RECALL (RCL), STATUS (STS) and emergency cancel (EMER
CANC) keys are linked to the
a- DMCs
b- FWCs
c- SDACs
7. When a new DU is installed, a cross loading from the corresponding DMC has to be performed via
a- MDDU
b- DATA loader
c- MCDU
9. A ________ pushbutton can be installed on the FCU. If you push this pushbutton, the selected altitude
is displayed in meters above the altitude scale.
a- METRIC ALT
b- MET
c- ALTERNATE
10. the _____are used by the FWCs to send text messages (warnings, MEMO and status) to the DMCs.
a- ARINC 429 buses
b- RS 422 buses
c- ARINC 639 buses
11. FWC, ECAM Control Panel (ECP), (ATSU), (FDIMU), gets data from DMC through
a- high speed switched bus.
b- low speed switched bus.
c- Either low or high speed bus.
16. In case of EWD unit and SD unit failure, each crew member has the possibility to permanently present
the
a- EWD on the ND unit.
b- EWD on PFD unit
c- EWD can not be transferred in both DU failure
17. no reconfiguration is possible In the case of PFD unit and ND unit failure
a- On opposite sides
b- On the same side
c- Reconfiguration is possible in all failure situations
18. In case of both SDAC failure, Wheel ECAM page data is available because
a- It sends data directly to CFDIU
b- It has direct bus connection with DUs
c- it is already in ARINC 429
19. To activate the Elapsed Time (ET) function, the ET selector must be set to
a- SET
b- RUN
c- GPS
21. In menu mode CFDIU dialogues with one computer at a time in order to read
a- RAM
b- Data loops
c- bite memory
23. When several identical and consecutive warnings are transmitted, the CFDIU memorizes the first
occurrence only and carries on counting with a maximum of
a- 8
b- 64
c- 11
26. an Angle-Of-Attack (AOA) sensor failure has been detected and that systems A, B and C are affected
by this failure. The Air Data System (ADS) will transmit
a- an internal failure
b- an external failure
c- an internal failure with independent fault.
27. What type of systems can memorize failures, which occurred in the last 64 flight legs?
a- Type 3 (CFDS)
b- Type 1 (CFDS)
c- ECAM computer
28. Previous leg report can store up to 200 failures over the last
a- 64 flight legs.
b- 60 flight legs
c- 20 days of flights
29. If the failure occurred intermittently, the PFR will have ______against fault details.
a- INHIBT
b- Asterisk
c- INTM
34. Only primary failures, INDEPENDENT failures and CLASS 2 failure messages (Maintenance status) are
received from
a- FWC
b- LRUs
c- SDAC
35. The CFDIU receives the engine serial number from the
a- (SDAC)
b- CFDIU
c- (DMC)
36. When the CFDIU is affected by an internal failure, the message CFDIU is displayed on the ECAM
a- Engine warning page
b- MAINTENANCE STATUS page.
c- CFDIU Bite on LRU
38. Data to printer is transmitted via Low Speed (LS) ARINC 429 buses, one at a time using a
a- Avionics protocol.
b- ARINIC protocol.
c- handshake protocol.