Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
V100R013C10
Technical Specifications
Issue 01
Date 2018-09-30
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Website: http://www.huawei.com
Email: support@huawei.com
Contents
The BBU5900 is a baseband processing unit and centrally manages the entire base station.
This document describes the product and engineering specifications of the BBU5900.
NOTE
l In this document, G is short for GSM, U is short for UMTS, L is short for LTE FDD, T is short for LTE
TDD, and M is short for LTE NB-IoT.
l Unless otherwise specified, LTE refers to LTE FDD, LTE TDD, or LTE NB-IoT, and eNodeB refers to
LTE FDD eNodeB, LTE TDD eNodeB, or LTE NB-IoT eNodeB. In scenarios where they need to be
distinguished, LTE FDD, LTE TDD, and LTE NB-IoT are used. The same rules apply to eNodeB.
Product Version
The following table lists the product versions related to this document.
DBS5900 l SRAN13.1
l GBSS20.1
l RAN20.1
l eRAN13.1
l eRAN TDD 13.1
Intended Audience
This document is intended for:
l System engineers
Organization
1.1 Changes in BBU5900 Technical Specifications
This section describes changes in BBU5900 Technical Specifications.
1.2 BBU5900 Technical Specifications
This section describes the technical specifications of BBUs, including capacity, baseband,
signaling, CPRI, transmission port, and equipment specifications.
01 (2018-09-30)
This is the first commercial release.
The content of BBU5900 Technical Specifications is removed from 5900 Series Base Station
Technical Description. From this issue onwards, this content constitutes a separate document.
Capacity Specifications
The following table lists the capacity specifications of the eGBTS.
Capacity Specifications
The following table lists the capacity specifications of the NodeB.
Signaling Specifications
The following table lists typical board configurations and the corresponding signaling
specifications of the NodeB.
Table 1-3 Typical board configurations and corresponding signaling specifications of the
NodeB
Main Control UBBPd1/UBBPd2/ UBBPd6/UBBPe3/ Signaling
Board UBBPd3/UBBPd4/ UBBPe4/UBBPe5/ Specifications
UBBPd5/UBBPe1/ UBBPe6 Boards (CNBAPS)
UBBPe2 Boards
UMPTb/UMPTe 1 0 500
UMPTb/UMPTe 2 0 700
UMPTb/UMPTe 3 0 900
UMPTb/UMPTe 4 0 1100
UMPTb/UMPTe 5 0 1300
UMPTb/UMPTe 6 0 1500
UMPTb/UMPTe 0 1 600
UMPTb/UMPTe 0 2 900
UMPTb/UMPTe 0 3 1200
UMPTb/UMPTe 0 ≥4 1500
Capacity Specifications
The following table provides the capacity specifications of an FDD eNodeB.
Item Specifications
Max cells per BBU l When configured with a UMPTb board: 36 cells (2T2R/
2T4R/4T4R, 20 MHz)
l When configured with a UMPTe board: 72 cells (2T2R/
2T4R/4T4R, 20 MHz)
Max DRBs per FDD l When configured with a UMPTb board: 32,400
eNodeB l When configured with a UMPTe board: 43,200
Table 1-5 Maximum number of UEs in RRC connected mode per cell served by an FDD
eNodeB
Cell BW Max UEs in RRC Connected Max UL Synchronized
Mode per Cell UEs per Cell
The following table lists the maximum number of UEs in RRC connected mode when an
FDD eNodeB uses the typical board configuration.
Table 1-6 Maximum number of UEs in RRC connected mode per FDD eNodeB
Board Configuration Max UEs in RRC Connected Mode
NOTE
Specifications in the preceding table are provided based on the assumption that the cell bandwidth is 20
MHz.
Throughput Specifications
The following tables provide the uplink and downlink throughput per UE, per cell, and per
baseband processing unit (BBP) supported by an FDD eNodeB.
Table 1-7 Maximum uplink and downlink throughput per UE supported by an FDD eNodeB
(DL 64QAM, UL 64QAM)
Table 1-8 Maximum uplink and downlink throughput per UE supported by an FDD eNodeB
(DL 256QAM)
NOTE
When LBBPd boards are used for 256QAM, the maximum throughput per UE is only 295.30 Mbit/s in
the scenario of 20 MHz cell bandwidth and DL 4x4 MIMO due to limitations of board throughput
specifications.
Table 1-9 Maximum uplink and downlink throughput per cell served by an FDD eNodeB (DL
64QAM, UL 64QAM)
TX/RX Multipl Throug Throug Throug Throug Throug Throug
Mode e- hput hput hput hput hput hput
Antenn (Mbit/s) (Mbit/s) (Mbit/s) (Mbit/s) (Mbit/s) (Mbit/s)
a (Cell (Cell (Cell (Cell (Cell (Cell
Techno BW: 20 BW: 15 BW: 10 BW: 5 BW: 3 BW: 1.4
logy MHz) MHz) MHz) MHz) MHz) MHz)
NOTE
(5):
Maximum uplink throughput per cell served by the LBBPc (2x2 MU-MIMO, 64QAM) is 100
Mbit/s.
Table 1-10 Maximum uplink and downlink throughput per cell served by an FDD eNodeB
(DL 256QAM)
NOTE
When LBBPd boards are used for 256QAM, the maximum throughput per cell is only 295.30 Mbit/s in
the scenario of 20 MHz cell bandwidth and DL 4x4 MIMO due to limitations of board throughput
specifications.
Signaling Specifications
Busy Hour Call Attempts (BHCA) is the number of calls attempted at a busy hour. Signaling
procedures required for completing a call may include call setup and release (including CS
fallback if it occurs) and the following activities during the on-hold call: handover, tracking
area update (TAU), bearer setup and release, and switching between the in-synchronization
state and the out-of-synchronization state. BHCA indicates the signaling processing
capabilities of a system.
A busy-hour call initiated on different operator networks involves different types and numbers
of signaling procedures and therefore consumes different amounts of eNodeB resources. As a
result, the BHCA capability varies depending on the call model.
The following table lists the signaling specifications of an FDD eNodeB based on the typical
board configuration and the definition of one BHCA, which is provided in Traffic Model.
Table 1-11 Signaling specifications of an FDD eNodeB with the typical board configuration
NOTE
Traffic Model
On live networks, the traffic capacity of an FDD eNodeB depends on the traffic model in
addition to system processing capacities. This section describes two traffic models.
l Traffic model 1 derives from a typical LTE network where smartphones dominate. UEs
in this traffic model are characterized by short online duration, frequent network access
and connection release, high mobility, and a large number of small-packet data services.
l Traffic model 2 derives from a typical LTE network where data cards dominate. LTE
dongles and customer premises equipment (CPE) are examples of such data cards. UEs
in this traffic model are characterized by long online durations, low mobility, and many
large-packet data services.
Traffic models used on operator networks may differ from those defined by Huawei.
Operators can use either of the two traffic models based on network characteristics to perform
initial network planning, and construct an industry-leading LTE network through continuous
capacity monitoring and expansion.
The following table describes the control-plane specifications for traffic models 1 and 2.
Intra-eNodeB Handover 10 1
Number per User @BH (times)
Inter-eNodeB X2 Based 40 2
Handover Out Attempt Number
per User @BH (times)
Inter-eNodeB X2 Based 40 2
Handover In Attempt Number
per User @BH (times)
Inter-eNodeB S1 Based 0 0
Handover Out Attempt Number
per User @BH (times)
Inter-eNodeB S1 Based 0 0
Handover In Attempt Number
per User @BH (times)
The following table describes the user-plane specifications for traffic model 1.
IM 15.00 5 0.7
Other 8.85 50 1
The following table describes the user-plane specifications for traffic model 2.
Based on the definition of traffic model 1, one BHCA (that is, one combined PS call) is
defined by taking every item in traffic model 1 divided by the PS call density. The details of
one BHCA are listed below. Based on this table, the BHCA specifications of equipment can
be defined in following chapters.
PS Call Attempts 1
Item Times
Syn2Unsyn Attempts 0
Unsyn2Syn Attempts 0
A3 Reports 0
Capacity Specifications
NOTE
UMPTb boards mentioned in this section include UMPTb2 and UMPTb9 boards.
Max cells per BBU l When configured with a UMPTb board: 36 cells
(2T2R/4T4R, 5/10/15/20 MHz) or 18 cells (8T8R,
10/15/20 MHz)
l When configured with a UMPTe board: 72 cells
(2T2R/4T4R, 5/10/15/20 MHz), 36 cells (8T8R,
10/15/20 MHz), or 18 cells (32T32R/64T64R,
10/15/20 MHz)
Item Specifications
Max UEs in RRC connected l When configured with a UMPTb board: 10,800
mode per TDD eNodeB l When configured with UMPTe boards:
– 1 UMPTe board: 14,400
– 2 UMPTe boards: 28,800
Max DRBs per TDD eNodeB l When configured with a UMPTb board: 32,400
l When configured with a UMPTe board: 43,200
NOTE
(2):When two main control boards are configured, transmission extension is supported and the maximum
throughput per TDD eNodeB can reach 3 Gbit/s only if the two main control boards are the UMPTb boards.
Table 1-17 Maximum number of UEs in RRC connected mode per cell served by a TDD
eNodeB
Cell BW Subframe Max UEs in RRC Max UL Synchronized
Configuration Connected Mode UEs per Cell
per Cell
Table 1-18 lists the maximum number of UEs in RRC connected mode when a TDD eNodeB
uses the typical board configuration.
Table 1-18 Maximum number of UEs in RRC connected mode per TDD eNodeB
Board Configuration Max UEs in RRC Max UL Synchronized UEs
Connected Mode
NOTE
Specifications in the preceding table are provided based on the assumption that the cell bandwidth is 20
MHz.
Throughput Specifications
l The following table lists the uplink and downlink throughput per cell served by a TDD
eNodeB (DL 64QAM, UL 16QAM, CAT6 UE).
Table 1-19 Maximum uplink and downlink throughput per TDD cell (DL 64QAM, UL
16QAM, CAT6 UE)
TX/RX Mode Subframe Throughput
Configuration
l The following table lists the uplink and downlink throughput per UE served by a TDD
eNodeB (DL 64QAM, UL 16QAM, CAT6 UE).
Table 1-20 Maximum uplink and downlink throughput per UE (DL 64QAM, UL
16QAM, CAT6 UE)
TX/RX Mode Subframe Throughput
Configuration
l The following table lists the uplink and downlink throughput per cell served by a TDD
eNodeB (DL 64QAM, UL 16QAM, CAT4 UE).
Table 1-21 Maximum uplink and downlink throughput per cell (DL 64QAM, UL
16QAM, CAT4 UE)
TX/RX Mode Subframe Throughput
Configuration
l The following table lists the uplink and downlink throughput per UE served by a TDD
eNodeB (DL 64QAM, UL 16QAM, CAT4 UE).
Table 1-22 Maximum uplink and downlink throughput per UE (DL 64QAM, UL
16QAM, CAT4 UE)
TX/RX Mode Subframe Throughput
Configuration
NOTE
Table 1-23 Maximum uplink and downlink throughput per cell served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT6 UE, 2T2R, SA1 (2:2))
Multiple- Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna MHz) MHz) MHz) MHz)
Technology
Table 1-24 Maximum uplink and downlink throughput per cell served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT6 UE, 2T2R, SA2 (3:1))
Multiple- Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna MHz) MHz) MHz) MHz)
Technology
Table 1-25 Maximum uplink and downlink throughput per cell served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT6 UE, 4T4R, SA1 (2:2))
UL 2x2 SU- / / / /
MIMO
Table 1-26 Maximum uplink and downlink throughput per cell served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT6 UE, 4T4R, SA2 (3:1))
Table 1-27 Maximum uplink and downlink throughput per cell served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT6 UE, 8T8R, SA1 (2:2))
Multiple-
Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna
MHz) MHz) MHz) MHz)
Technology
UL 2x2 SU-MIMO / / / /
UL 4x8 MU- / / / /
MIMO
Table 1-28 Maximum uplink and downlink throughput per cell served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT6 UE, 8T8R, SA2 (3:1))
Multiple-
Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna
MHz) MHz) MHz) MHz)
Technology
Multiple-
Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna
MHz) MHz) MHz) MHz)
Technology
Table 1-29 Maximum uplink and downlink throughput per cell served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT6 UE, 64T64R, SA1 (2:2))
Multiple-
Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna
MHz) MHz) MHz) MHz)
Technology
DL 24-layer MU / / / /
beamforming
UL 2x2 SU-MIMO / / / /
Table 1-30 Maximum uplink and downlink throughput per cell served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT6 UE, 64T64R, SA2 (3:1))
Multiple-
Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna
MHz) MHz) MHz) MHz)
Technology
DL 4x4 MIMO / / / /
(TM3)
DL 4x4 MIMO / / / /
(TM4)
UL 2x2 SU-MIMO / / / /
Table 1-31 Maximum uplink and downlink throughput per UE served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT6 UE, 2T2R, SA1 (2:2))
Multiple- Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna MHz) MHz) MHz) MHz)
Technology
Table 1-32 Maximum uplink and downlink throughput per UE served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT6 UE, 2T2R, SA2 (3:1))
Multiple- Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna MHz) MHz) MHz) MHz)
Technology
Table 1-33 Maximum uplink and downlink throughput per UE served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT6 UE, 4T4R, SA1 (2:2))
Multiple- Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna MHz) MHz) MHz) MHz)
Technology
UL 2x2 SU-MIMO / / / /
UL 2x4 MU- / / / /
MIMO
Table 1-34 Maximum uplink and downlink throughput per UE served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT6 UE, 4T4R, SA2 (3:1))
Multiple- Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna MHz) MHz) MHz) MHz)
Technology
UL 2x4 MU- / / / /
MIMO
Table 1-35 Maximum uplink and downlink throughput per UE served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT6 UE, 8T8R, SA1 (2:2))
Multiple-
Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna
MHz) MHz) MHz) MHz)
Technology
UL 2x2 SU-MIMO / / / /
UL 2x8 MU- / / / /
MIMO
UL 4x8 MU- / / / /
MIMO
Table 1-36 Maximum uplink and downlink throughput per UE served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT6 UE, 8T8R, SA2 (3:1))
Multiple-
Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna
MHz) MHz) MHz) MHz)
Technology
UL 2x8 MU-MIMO / / / /
UL 4x8 MU-MIMO / / / /
Table 1-37 Maximum uplink and downlink throughput per UE served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT6 UE, 64T64R, SA1 (2:2))
Multiple-
Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna
MHz) MHz) MHz) MHz)
Technology
Multiple-
Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna
MHz) MHz) MHz) MHz)
Technology
UL 2x2 SU-MIMO / / / /
Table 1-38 Maximum uplink and downlink throughput per UE served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT6 UE, 64T64R, SA2 (3:1))
Multiple-
Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna
MHz) MHz) MHz) MHz)
Technology
DL 4x4 MIMO / / / /
(TM3)
DL 4x4 MIMO / / / /
(TM4)
UL 2x2 SU-MIMO / / / /
Multiple-
Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna
MHz) MHz) MHz) MHz)
Technology
Table 1-39 Maximum uplink and downlink throughput per cell served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT4 UE, 2T2R, SA1 (2:2))
Multiple- Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna MHz) MHz) MHz) MHz)
Technology
Table 1-40 Maximum uplink and downlink throughput per cell served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT4 UE, 2T2R, SA2 (3:1))
Multiple- Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna MHz) MHz) MHz) MHz)
Technology
Table 1-41 Maximum uplink and downlink throughput per cell served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT4 UE, 4T4R, SA1 (2:2))
Multiple- Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna MHz) MHz) MHz) MHz)
Technology
DL 4x4 MIMO / / / /
(TM9)
DL 4x4 MIMO / / / /
(TM3)
DL 4x4 MIMO / / / /
(TM4)
UL 2x2 SU-MIMO / / / /
Table 1-42 Maximum uplink and downlink throughput per cell served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT4 UE, 4T4R, SA2 (3:1))
Multiple-Antenna Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Technology MHz) MHz) MHz) MHz)
DL 4x4 MIMO / / / /
(TM9)
DL 4x4 MIMO / / / /
(TM3)
DL 4x4 MIMO / / / /
(TM4)
Table 1-43 Maximum uplink and downlink throughput per cell served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT4 UE, 8T8R, SA1 (2:2))
Multiple-Antenna Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Technology MHz) MHz) MHz) MHz)
DL 4x4 MIMO / / / /
(TM9)
DL 4x4 MIMO / / / /
(TM3)
DL 4x4 MIMO / / / /
(TM4)
UL 2x2 SU-MIMO / / / /
UL 4x8 MU-MIMO / / / /
Table 1-44 Maximum uplink and downlink throughput per cell served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT4 UE, 8T8R, SA2 (3:1))
Multiple-Antenna Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Technology MHz) MHz) MHz) MHz)
DL 4x4 MIMO / / / /
(TM9)
DL 4x4 MIMO / / / /
(TM3)
DL 4x4 MIMO / / / /
(TM4)
Table 1-45 Maximum uplink and downlink throughput per cell served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT4 UE, 64T64R, SA1 (2:2))
Multiple-Antenna Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Technology MHz) MHz) MHz) MHz)
DL 4x4 MIMO / / / /
(TM9)
DL 4x4 MIMO / / / /
(TM3)
DL 4x4 MIMO / / / /
(TM4)
DL 24-layer MU / / / /
beamforming
UL 2x2 SU-MIMO / / / /
Table 1-46 Maximum uplink and downlink throughput per cell served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT4 UE, 64T64R, SA2 (3:1))
Multiple-
Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna
MHz) MHz) MHz) MHz)
Technology
DL 4x4 MIMO / / / /
(TM9)
DL 4x4 MIMO / / / /
(TM3)
DL 4x4 MIMO / / / /
(TM4)
Multiple-
Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna
MHz) MHz) MHz) MHz)
Technology
UL 2x2 SU- / / / /
MIMO
Table 1-47 Maximum uplink and downlink throughput per UE served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT4 UE, 2T2R, SA1 (2:2))
Multiple- Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna MHz) MHz) MHz) MHz)
Technology
Table 1-48 Maximum uplink and downlink throughput per UE served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT4 UE, 2T2R, SA2 (3:1))
Multiple- Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna MHz) MHz) MHz) MHz)
Technology
Table 1-49 Maximum uplink and downlink throughput per UE served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT4 UE, 4T4R, SA1 (2:2))
Multiple- Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna MHz) MHz) MHz) MHz)
Technology
DL 4x4 MIMO / / / /
(TM9)
DL 4x4 MIMO / / / /
(TM3)
DL 4x4 MIMO / / / /
(TM4)
UL 2x2 SU- / / / /
MIMO
UL 2x4 MU- / / / /
MIMO
Table 1-50 Maximum uplink and downlink throughput per UE served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT4 UE, 4T4R, SA2 (3:1))
Multiple- Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna MHz) MHz) MHz) MHz)
Technology
DL 4x4 MIMO / / / /
(TM9)
DL 4x4 MIMO / / / /
(TM3)
DL 4x4 MIMO / / / /
(TM4)
UL 2x4 MU- / / / /
MIMO
Table 1-51 Maximum uplink and downlink throughput per UE served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT4 UE, 8T8R, SA1 (2:2))
Multiple-
Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna
MHz) MHz) MHz) MHz)
Technology
DL 4x4 MIMO / / / /
(TM9)
DL 4x4 MIMO / / / /
(TM3)
DL 4x4 MIMO / / / /
(TM4)
UL 2x2 SU- / / / /
MIMO
UL 2x8 MU- / / / /
MIMO
UL 4x8 MU- / / / /
MIMO
Table 1-52 Maximum uplink and downlink throughput of a single UE served by an eNodeB
TDD (DL 64QAM, UL 16QAM, CAT4 UE, 8T8R, SA2 (3:1))
Multiple-
Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna
MHz) MHz) MHz) MHz)
Technology
DL 4x4 MIMO / / / /
(TM9)
DL 4x4 MIMO / / / /
(TM3)
DL 4x4 MIMO / / / /
(TM4)
UL 2x8 MU- / / / /
MIMO
Multiple-
Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna
MHz) MHz) MHz) MHz)
Technology
UL 4x8 MU- / / / /
MIMO
Table 1-53 Maximum uplink and downlink throughput per UE served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT4 UE, 64T64R, SA1 (2:2))
Multiple-
Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna
MHz) MHz) MHz) MHz)
Technology
DL 4x4 MIMO / / / /
(TM9)
DL 4x4 MIMO / / / /
(TM3)
DL 4x4 MIMO / / / /
(TM4)
UL 2x2 SU- / / / /
MIMO
Table 1-54 Maximum uplink and downlink throughput per UE served by a TDD eNodeB (DL
64QAM, UL 16QAM, CAT4 UE, 64T64R, SA2 (3:1))
Multiple-
Cell BW (20 Cell BW (15 Cell BW (10 Cell BW (5
Antenna
MHz) MHz) MHz) MHz)
Technology
DL 4x4 MIMO / / / /
(TM3)
DL 4x4 MIMO / / / /
(TM4)
UL 2x2 SU- / / / /
MIMO
Traffic Model lists the signaling specifications of a TDD eNodeB based on the typical board
configuration and the definition of BHCA.
Table 1-55 Signaling specifications and number of UEs in RRC connected mode per TDD
eNodeB
Board Configuration Signaling Specifications (BHCA)
NOTE
If the traffic model changes, the BHCA specifications of the equipment change
correspondingly.
Traffic Model
On live networks, the service capacity of a TDD eNodeB depends on system processing
capacities in addition to the traffic model used. This section describes two traffic models.
l Traffic model 1 derives from a typical LTE network where smartphones dominate. UEs
in this traffic model are characterized by short online duration, frequent network access
and connection release, high mobility, and a large number of small-packet data services.
l Traffic model 2 derives from a typical LTE network where data cards dominate. LTE
dongles and customer premises equipment (CPE) are examples of such data cards. UEs
in this traffic model are characterized by long online durations, low mobility, and many
large-packet data services.
The following table describes the control-plane specifications for traffic models 1 and 2.
NOTE
(1): @BH means "at busy hour". Traffic models described in the table are obtained during busy hours.
Intra-eNodeB Handover 10 1
Number per User @BH (times)
Inter-eNodeB X2 Based 40 2
Handover Out Attempt Number
per User @BH (times)
Inter-eNodeB X2 Based 40 2
Handover In Attempt Number
per User @BH (times)
Inter-eNodeB S1 Based 0 0
Handover Out Attempt Number
per User @BH (times)
Inter-eNodeB S1 Based 0 0
Handover In Attempt Number
per User @BH (times)
The following table describes the user-plane specifications for traffic model 1.
IM 15.00 5 0.7
Other 8.85 50 1
The following table describes the user-plane specifications for traffic model 2.
Based on the definition of traffic model 1, one BHCA (that is, one combined PS call) is
defined by taking every item in traffic model 1 divided by the PS call density. The details of
one BHCA are listed below. Based on this table, the BHCA specifications of equipment can
be defined in following chapters.
PS Call Attempts 1
Syn2Unsyn Attempts 0
Unsyn2Syn Attempts 0
A3 Reports 0
Capacity Specifications
The following table provides the capacity specifications of an NB-IoT eNodeB.
Item Specifications
Max throughput l When configured with a UMPTb board: The uplink data
rate at the MAC layer is 7.2 Mbit/s; the downlink data
rate at the MAC layer is 3.8 Mbit/s.
l When configured with a UMPTe board: The uplink data
rate at the MAC layer is 14.4 Mbit/s; the downlink data
rate at the MAC layer is 7.6 Mbit/s.
Max UEs in RRC connected l When configured with a UMPTb board: 10,800
mode l When configured with a UMPTe board: 14,400
Specifications in the following table are provided based on the assumption that the cell bandwidth is 200
kHz.
The following table lists the maximum number of UEs per cell served by an NB-IoT eNodeB.
Table 1-61 Maximum number of UEs per cell served by an NB-IoT eNodeB
Item Specifications
The following table provides the maximum number of UEs when an NB-IoT eNodeB uses the
typical board configuration.
Signaling Specifications
Busy Hour Call Attempts (BHCA) is the number of calls attempted at a busy hour. Signaling
procedures required for completing a call may include call setup and release (including CS
fallback if it occurs) and the following activities during the on-hold call: handover, TAU,
bearer setup and release, and switching between the in-synchronization state and the out-of-
synchronization state. BHCA indicates the signaling processing capabilities of a system.
A busy-hour call initiated on different operator networks involves different types and numbers
of signaling procedures and therefore consumes different amounts of LTE system resources.
As a result, the BHCA capability varies depending on the call model.
The following table lists the signaling specifications of an NB-IoT eNodeB with the typical
board configuration.
NOTE
Traffic Model
On live networks, the traffic capacity of an NB-IoT eNodeB depends on the traffic model in
addition to system processing capacities. This section describes the traffic models defined in
3GPP TR 45.820.
24 40%
2 40%
1 15%
0.5 5%
0 (0 dB) 100%
1 (10 dB) 0%
2 (20 dB) 0%
NOTE
l (1): @BH means "at busy hour". Traffic models described in the table are obtained during busy hours.
l (2): Periodic TAU timer is extended to 310 hours.
Capacity Specifications
The following table lists the capacity specifications of an LM eNodeB.
Item Specifications
Item Specifications
Max UEs in RRC connected l When configured with a UMPTb board: 10,800
mode l When configured with a UMPTe board: 14,400
NOTE
LTE FDD and LTE NB-IoT share the capacity of the main control board in terms of the maximum
number of cells and the maximum number of UEs in RRC connected mode.
Table 1-69 Maximum number of UEs per cell served by an FDD+NB-IoT eNodeB
Item Specifications
NOTE
TDD+NB-IoT specifications are supported only when TDD uplink-downlink subframe configuration 1 or 2 is
used.
Table 1-70 Maximum number of UEs per cell served by a TDD+NB-IoT eNodeB
Item Specifications
Capacity Specifications
The following table provides the capacity specifications of a 5900 series base station working
in FDD+TDD mode.
Item Specifications
NOTE
l LTE FDD and LTE TDD dynamically share the specifications of the main control board.
Capacity Specifications
The following tables list the capacity specifications of a 5900 series base station working in
GU/GL/GUL mode.
NOTE
l For GSM, GA/A/A indicates that three cells are configured and each cell has A TRXs.
l For UMTS, BxC indicates that B sectors are configured and each sector has C carriers.
l For LTE, DxE MHz indicates that D cells are configured and each cell is configured with E MHz
bandwidth.
l The capacity specifications of a UL base station are the same as those of a GUL base station.
l In typical GL/UL/GUL scenarios, LTE FDD and LTE TDD dynamically share the LTE specifications on
the main control board.
l If GSM is configured with 72 TRXs (G24/24/24), each TRX can be configured with only one SDCCH; if
GSM is configured with 24 TRXs (G8/8/8), each TRX can be configured with three SDCCHs.
l In typical GL/UL/GUL scenarios where the capacity specifications of GSM and UMTS remain
unchanged, the allocation of LTE capacity specifications of the main control board is affected after NB-
IoT is introduced. That is, LTE FDD and NB-IoT now share the original maximum number of LTE FDD
cells and UEs in RRC connected mode of the main control board.
Signaling Specifications
Table 1-75 lists the signaling specifications of a co-MPT multimode base station with typical
configurations.
NOTE
l If GSM is configured with 72 TRXs (G24/24/24), each TRX can be configured with only one
SDCCH; if GSM is configured with 24 TRXs (G8/8/8), each TRX can be configured with three
SDCCHs.
l The following specifications are met only in typical configurations. For example, the number of
SCTP links required for GSM can be reached only when the typical configuration is used.
l LTE FDD and TDD dynamically share the LTE specifications of the main control board.
l In typical GL/UL/GUL scenarios where the signaling specifications of GSM and UMTS remain
unchanged, the allocation of LTE FDD signaling specifications (BHCA) on the main control board is
affected after NB-IoT is introduced. That is, LTE FDD and NB-IoT share LTE signaling processing
specifications of the main control board. For commercial networks, it is recommended that 30% of
the signaling processing specifications be allocated to LTE NB-IoT.
NOTE
LTE FDD
The following table lists the maximum number of UEs in RRC connected mode per main
control board working in LTE FDD mode.
Table 1-76 Maximum number of UEs in RRC connected mode per main control board
The following table lists the maximum number of DRBs per main control board.
UMPTb 32400
UMPTe 43200
The following table lists the signaling specifications of the boards based on the definition of
one BHCA in Traffic Model.
UMPTb 360000
UMPTe 1620000
LTE TDD
The following table lists the maximum number of UEs in RRC connected mode per main
control board working in LTE TDD mode.
Table 1-79 Maximum number of UEs in RRC connected mode per main control board
UMPTb 10800
UMPTe 14400
The maximum number of DRBs per UMPT is three times the maximum number of UEs in
RRC connected mode per board.
The following table lists the signaling specifications of the UMPT boards based on the
definition of one BHCA in Traffic Model.
Table 1-80 Signaling specifications per UMPT working in LTE TDD mode
UMPTb 360000
UMPTe 1620000
LTE NB-IoT
The following table lists the maximum number of UEs per main control board working in
LTE NB-IoT mode.
The following table lists the signaling specifications per main control board working in LTE
NB-IoT mode.
UMPTb 540000
UMPTe 2430000
FDD+NB-IoT
The following table lists the number of UEs per main control board working in LM mode.
Table 1-83 Maximum number of UEs per main control board working in LM mode
NOTE
l (1):
In A+B in the preceding table, A indicates the maximum number of LTE FDD UEs in RRC
connected mode supported by this board and B indicates the maximum number of LTE NB-IoT UEs
supported by this board.
l In the preceding table, LTE FDD cell bandwidth is 20 MHz and LTE NB-IoT cell bandwidth is 200
kHz.
The following table lists the signaling specifications per main control board working in LM
mode.
UMPTb 252000+161000
UMPTe 1296000+484000
NOTE
l (1):
In A+B in the preceding table, A indicates the maximum LTE FDD signaling specifications
supported by this board and B indicates the maximum LTE NB-IoT signaling specifications
supported by this board.
l The signaling specifications of an eNodeB cannot exceed 4,860,000 BHCA.
FDD+TDD
The following table lists the signaling specifications per main control board working in LT
mode.
UMPTb 360000
UMPTe 1620000
NOTE
LTE FDD and LTE TDD dynamically share the specifications of the main control board.
GSM
The following table lists the carrier specifications per UBBP working in GSM mode.
UBBPd1/UBBPd2/ 24 12
UBBPd3/UBBPd4
UBBPd5 36 18
UBBPd6 48 24
UMTS
The following table lists the baseband specifications per UBBP working in UMTS mode.
NOTE
l For details about the UBBP supporting 2R or 4R cells, see NodeB Baseband Resource Management
Feature Parameter Description.
l For a UBBP series board, 2R and 4R cells can be configured together. Assume that the board
supports mixed configuration of x 2R cells and y 4R cells in UMTS mode (x and y are greater than
0). The following conditions must be met:
l UBBPd2/UBBPd4/UBBPd5/UBBPe2: (x + y) ≤ 6
l UBBPd1/UBBPd3/UBBPd6/UBBPe1/UBBPe3/UBBPe4/UBBPe5/UBBPe6/UBBPei: (x + 2y)
≤ Number of 2R cells supported by the board and y < Number of 4R cells supported by the
board
LTE FDD
The following table describes the cell specifications per UBBP working in LTE FDD mode.
NOTE
l Hybrid configurations of 1R and 2R cells are supported. In these configurations, the total number of cells
cannot exceed the maximum number of 2R cells.
l Hybrid configurations of 1R and 4R cells or 2R and 4R cells are supported. In these configurations, the
total number of cells cannot exceed the maximum number of 4R cells.
l Software mapping of the UBBPex2 is as follows: BTS3900 V100R013C10SPC230 (or later), BTS3900
V100R015C00SPC120 (or later), and BTS3900 V100R015C10SPC080 (or later).
The following table lists the maximum number of UEs in RRC connected mode per UBBP
working in LTE FDD mode.
Table 1-89 Maximum number of UEs in RRC connected mode per UBBP
Board Cell BW Max UEs in RRC Max UL
Connected Mode Synchronized UEs
The following table lists the maximum number of DRBs per BBP.
UBBPd3/UBBPd4/UBBPd5/UBBPd6 10,800
UBBPe1/UBBPe2/UBBPe3/UBBPe4/ 10,800
UBBPe5
UBBPe6 14,400
UBBPei 14,400
UBBPex2 7200
The following table lists the uplink and downlink throughput per UBBP working in LTE FDD
mode.
The following table lists the signaling specifications of the boards based on the definition of
one BHCA in Traffic Model.
UBBPd3/UBBPd4 270,000
UBBPd5/UBBPd6 396,000
UBBPe1/UBBPe2 270,000
UBBPe3/UBBPe4 432,000
UBBPe5 540,000
UBBPe6 648,000
UBBPei 648,000
UBBPex2 432,000
In addition to highly efficient data services, the LTE network provides high quality VoLTE
services by specifying the QoS class identifier (QCI). VoLTE services are characterized by a
low data rate and a large number of regular small packets, which place high requirements on
the system processing delay and packet processing speed.
Capacity specifications of VoLTE refer to the maximum number of VoLTE UEs that can be
processed by the eNodeB when radio conditions are not considered. The following table lists
the maximum number of VoLTE UEs per BBP.
UBBPd3/UBBPd4 720
UBBPd5/UBBPd6 1000
UBBPe1/UBBPe2 720
UBBPe3/UBBPe4 1200
UBBPe5 1400
UBBPe6 1600
UBBPei 1600
UBBPex2 1600
As one of the most important features in LTE-A networks, CA provides a peak data rate of 1
Gbit/s by aggregating contiguous carriers or non-contiguous carriers. A CA UE is served by a
primary component carrier (PCC) and at least one secondary component carrier (SCC).
According to the architecture and working principles of CA, a UE on its PCC consumes more
baseband processing resources than a non-CA UE performing data services, and a UE on one
of its SCCs consumes fewer baseband processing resources than a non-CA UE performing
data services.
Huawei uses model 1 to define the maximum number of CA UEs. The following table lists
the maximum number of CA UEs per BBP.
UBBPd3 750 (750 PCC 500 (500 PCC 375 (375 PCC 300 (300 PCC
+ 750 SCC) + 500 SCC + 375 SCC + 300 SCC
+ 500 SCC) + 375 SCC + 300 SCC
+ 375 SCC) + 300 SCC
+ 300 SCC)
UBBPd4 750 (750 PCC 500 (500 PCC 375 (375 PCC 300 (300 PCC
+ 750 SCC) + 500 SCC + 375 SCC + 300 SCC
+ 500 SCC) + 375 SCC + 300 SCC
+ 375 SCC) + 300 SCC
+ 300 SCC)
UBBPd5 1100 (1100 730 (730 PCC 550 (550 PCC 440 (440 PCC
PCC + 1100 + 730 SCC + 550 SCC + 440 SCC
SCC) + 730 SCC) + 550 SCC + 440 SCC
+ 550 SCC) + 440 SCC
+ 440 SCC)
UBBPd6 1100 (1100 730 (730 PCC 550 (550 PCC 440 (440 PCC
PCC + 1100 + 730 SCC + 550 SCC + 440 SCC
SCC) + 730 SCC) + 550 SCC + 440 SCC
+ 550 SCC) + 440 SCC
+ 440 SCC)
UBBPe1 750 (750 PCC 500 (500 PCC 375 (375 PCC 300 (300 PCC
+ 750 SCC) + 500 SCC + 375 SCC + 300 SCC
+ 500 SCC) + 375 SCC + 300 SCC
+ 375 SCC) + 300 SCC
+ 300 SCC)
UBBPe2 750 (750 PCC 500 (500 PCC 375 (375 PCC 300 (300 PCC
+ 750 SCC) + 500 SCC + 375 SCC + 300 SCC
+ 500 SCC) + 375 SCC + 300 SCC
+ 375 SCC) + 300 SCC
+ 300 SCC)
UBBPe3 1200 (1200 800 (800 PCC 600 (600 PCC 480 (480 PCC
PCC + 1200 + 800 SCC + 600 SCC + 480 SCC
SCC) + 800 SCC) + 600 SCC + 480 SCC
+ 600 SCC) + 480 SCC
+ 480 SCC)
UBBPe4 1200 (1200 800 (800 PCC 600 (600 PCC 480 (480 PCC
PCC + 1200 + 800 SCC + 600 SCC + 480 SCC
SCC) + 800 SCC) + 600 SCC + 480 SCC
+ 600 SCC) + 480 SCC
+ 480 SCC)
UBBPe5 1500 (1500 1000 (1000 750 (750 PCC 600 (600 PCC
PCC + 1500 PCC + 1000 + 750 SCC + 600 SCC
SCC) SCC + 1000 + 750 SCC + 600 SCC
SCC) + 750 SCC) + 600 SCC
+ 600 SCC)
UBBPe6 1800 (1800 1200 (1200 900 (900 PCC 720 (720 PCC
PCC + 1800 PCC + 1200 + 900 SCC + 720 SCC
SCC) SCC + 1200 + 900 SCC + 720 SCC
SCC) + 900 SCC) + 720 SCC
+ 720 SCC)
UBBPei 1800 (1800 1200 (1200 900 (900 PCC 720 (720 PCC
PCC + 1800 PCC + 1200 + 900 SCC + 720 SCC
SCC) SCC + 1200 + 900 SCC + 720 SCC
SCC) + 900 SCC) + 720 SCC
+ 720 SCC)
UBBPex2 1200 (1200 800 (800 PCC 600 (600 PCC 480 (480 PCC
PCC + 1200 + 800 SCC + 600 SCC + 480 SCC
SCC) + 800 SCC) + 600 SCC + 480 SCC
+ 600 SCC) + 480 SCC
+ 480 SCC)
NOTE
l In traffic model 1, the value of (Number of non-CA UEs carried on a BBP + Number of PCC-served UEs
on the board x [1 + (N – 1) x 0.5] + Number of SCC-served UEs on the board x 0.5) is less than or equal
to the maximum number of UEs in RRC connected mode supported by the board. N is the number of
component carriers for CA. For example, the value of N is 2 for 2CC CA.
l The maximum number of PCC-served UEs per board cannot exceed the value listed in this table.
For example, the UBBPd3 board supports a maximum of 750 PCC-served 2CC CA UEs or 500
PCC-served 3CC CA UEs when it carries only PCC-served UEs.
l In traffic model 1, the sum of (Number of non-CA UEs + Number of PCC-served UEs + Number of
SCC-served UEs carried on a board) is less than or equal to the maximum number of UEs in RRC
connected mode on the board.
LTE TDD
The following table describes the cell specifications per UBBP working in LTE TDD mode.
NOTE
l The UBBPe/UBBPei supports the hybrid configuration of 2R and 4R cells. In this scenario, the
UBBPe/UBBPei can be configured with a maximum of six cells.
l The UBBPe/UBBPei supports hybrid configurations of 2R and 8R cells or 4R and 8R cells. In this
scenario, the UBBPe/UBBPei can be configured with a maximum of three cells.
l The UBBPem/UBBPf1 cannot be used with the UMPTb.
The following table lists the maximum number of UEs in RRC connected mode per UBBP
working in LTE TDD mode.
Table 1-96 Maximum number of UEs in RRC connected mode per UBBP
The maximum number of DRBs per UBBP is three times the maximum number of UEs in
RRC connected mode per board.
Table 1-97 Maximum uplink and downlink throughput per BBP in a TDD eNodeB
Board Max DL Throughput per BBP Max UL Throughput per BBP
(Mbit/s) (Mbit/s)
The following table lists the signaling specifications of the UBBP boards based on the
definition of one BHCA in Traffic Model.
Table 1-98 Signaling specifications per UBBP working in LTE TDD mode
Board Specifications (BHCA)
UBBPd4 270,000
UBBPd6/UBBPd9 396,000
UBBPe4 432,000
UBBPe6 648,000
UBBPem 648,000
UBBPei 648,000
UBBPf1 648,000
LTE NB-IoT
The following table describes cell specifications per UBBP working in LTE NB-IoT mode.
NOTE
l Hybrid configurations of 1R and 2R cells are supported. In these configurations, the total number of
cells cannot exceed the maximum number of 2R cells.
l Hybrid configurations of 1R and 4R cells or 2R and 4R cells are supported. In these configurations,
the total number of cells cannot exceed the maximum number of 4R cells.
l (5):If a 400 kHz cell has been set up, the total number of cells cannot exceed three. If more than
three 200 kHz 4T4R cells have been set up, no 400 kHz cell can be set up.
l (6):
l For 4T4R cells, if a 400 kHz 4T4R cell has been set up, the total number of 4T4R cells cannot
exceed three. If more than three 200 kHz 4T4R cells have been set up, no 400 kHz cell can be
set up.
l For 2T4R cells, if more than six 2T4R cells have been set up, no 4T4R cell can be set up. If a
400 kHz 2T4R cell has been set up, the total number of cells cannot exceed six and the total
number of 400 kHz cells cannot exceed three. If more than six 200 kHz cells have been set up,
no 400 kHz cell can be set up.
l (7):
If a 400 kHz cell has been set up, the total number of cells cannot exceed six and the total
number of 400 kHz cells cannot exceed three. If more than six 200 kHz cells have been set up, no
400 kHz cell can be set up.
l (8):
If a 400 kHz cell or a 4T4R cell has been set up, the total number of cells cannot exceed six. If
more than six 2T4R cells have been set up, neither 400 kHz cells nor 4T4R cells can be set up.
l (9):
If a 400 kHz cell has been set up, the total number of cells cannot exceed six. If more than six
200 kHz cells have been set up, no 400 kHz cell can be set up.
l (10): If a 400 kHz cell has been set up, the total number of cells cannot exceed twelve. If more than
twelve 200 kHz cells have been set up, no 400 kHz cell can be set up.
The following table lists the maximum number of UEs per BBP working in LTE NB-IoT
mode.
The following table provides the maximum uplink and downlink throughput per BBP working
in LTE NB-IoT mode.
Table 1-101 Maximum uplink and downlink throughput per BBP in an LTE NB-IoT eNodeB
Board Max DL Throughput per Max UL Throughput per
BBP (Mbit/s) BBP (Mbit/s)
The following table lists the signaling specifications of a BBP working in LTE NB-IoT.
UBBPd3/UBBPd4 405,000
UBBPd5/UBBPd6 594,000
UBBPe1/UBBPe2 405,000
UBBPe3/UBBPe4 648,000
UBBPe5 810,000
UBBPe6 972,000
FDD+NB-IoT
The following table lists the cell specifications of the BBPs working in LM mode.
NOTE
l Hybrid configurations of 1R and 2R cells are supported. In these configurations, the total number of
cells cannot exceed the maximum number of 2R cells.
l Hybrid configurations of 1R and 4R cells or 2R and 4R cells are supported. In these configurations,
the total number of cells cannot exceed the maximum number of 4R cells.
l When the UBBPd is used to serve LTE NB-IoT cells, the maximum throughput of the board
decreases. The decrease in the maximum throughput is proportional to the decrease in the total
bandwidth of LTE cells.
l For a UBBPd/UBBPe, each LTE FDD cell can be associated with one inband LTE NB-IoT cell. (For
a UBBPd, if Standard Ratio is set to FDD_ENHANCE, FDD cells cannot share bandwidth to set
up inband NB-IoT cells.)
l Work Mode can be set to FDD_NBIOT_CUSTOM only for the LBBPd3 and LBBPd5 boards.
l For an LBBPd, each LTE FDD cell can be associated with one inband carrier. For a UBBPd/UBBPe,
each LTE FDD cell can be associated with two inband carriers. For an LBBPd, FDD cells cannot be
associated with 4T4R inband NB-IoT carriers. For a UBBPd, if Standard Ratio is set to
FDD_ENHANCE, FDD cells cannot be associated with inband NB-IoT carriers.
l For a UBBPd5/UBBPd6, if Standard Ratio is set to NBIOT_ENHANCE, the configuration of
3x400 kHz 4T4R LTE NB-IoT cells is supported. For a UBBPe6, if Standard Ratio is set to
NBIOT_ENHANCE, the configuration of 6x400 kHz 4T4R LTE NB-IoT cells is supported.
The following table lists the number of UEs supported per BBP working in LM mode.
NOTE
l (1):
In A+B in the preceding table, A indicates the maximum number of LTE FDD UEs in RRC
connected mode supported by this board and B indicates the maximum number of LTE NB-IoT UEs
supported by this board.
l In the preceding table, LTE FDD cell bandwidth is 20 MHz and LTE NB-IoT cell bandwidth is 200
kHz.
l In LM scenarios, LTE FDD and LTE NB-IoT share baseband resources.
The following table provides the uplink and downlink throughput per BBP working in LM
mode.
Table 1-105 Maximum uplink and downlink throughput per BBP working in LM mode
Board Max DL Throughput per BBP Max UL Throughput per BBP
(Mbit/s) (Mbit/s)
The following table lists the signaling specifications of the BBPs working in LM mode.
UBBPd3/UBBPd4 189,000+121,000
UBBPd5/UBBPd6 277,000+177,000
UBBPe1/UBBPe2 189,000+121,000
UBBPe3/UBBPe4 302,000+193,000
UBBPe5 378,000+242,000
UBBPe6 454,000+292,000
NOTE
l (1):
In A+B in the preceding table, A indicates the maximum LTE FDD signaling specifications
supported by this board and B indicates the maximum LTE NB-IoT signaling specifications
supported by this board.
l The signaling specifications of an eNodeB cannot exceed 4,860,000 BHCA.
TDD+NB-IoT
NOTE
TDD+NB-IoT specifications are supported only when TDD uplink-downlink subframe configuration
SA1 or SA2 is used.
The following table lists the cell specifications of the UBBPs working in TM mode.
The following table lists the number of UEs supported per UBBP working in TM mode.
NOTE
l (1):
In A+B in the preceding table, A indicates the maximum number of LTE TDD UEs in RRC
connected mode supported by this board and B indicates the maximum number of LTE NB-IoT UEs
supported by this board.
l Specifications in the preceding table are provided based on the assumption that the LTE TDD cell
bandwidth is 20 MHz.
The following table provides the uplink and downlink throughput per BBP working in TM
mode.
Table 1-109 Maximum uplink and downlink throughput per BBP working in TM mode
The following table lists the signaling specifications of a UBBP working in TM mode.
UBBPe4 302,000+193,000
UBBPe6 454,000+292,000
NOTE
l (1):
In A+B in the preceding table, A indicates the maximum LTE TDD signaling specifications
supported by this board and B indicates the maximum LTE NB-IoT signaling specifications
supported by this board.
l The signaling specifications of an eNodeB cannot exceed 4,860,000 BHCA.
Multi-RAT
In co-BBP scenarios, the baseband signals of multiple RATs are processed by one baseband
processing board. Co-BBP specifications refer to the maximum processing capability per
baseband processing board when it processes baseband signals of multiple RATs at the same
time. For example, GL co-BBP specifications refer to the maximum processing capability per
baseband processing board when it processes GSM and LTE FDD baseband signals
simultaneously.
The following tables provide GU/GL/UL/UM/GUL/ULM co-BBP specifications.
NOTE
l For a UBBPd3/UBBPd4 board working in co-BBP mode of which the supported RATs include GSM
and LTE (for example, GL co-BBP), an LTE FDD cell cannot be associated with any inband NB-IoT
cell.
l In co-MPT scenarios, a UBBPe board can function as a GSM CPRI interface board, connecting to
RF modules that process GSM baseband signals.
l If LTE and related NB inband cells are set up on different baseband processing boards, baseband
signals can be forwarded by the UBBP but cannot be forwarded by the WBBP.
Item TRXs TRXs Max Cells Max UEs in RRC Max DL/UL
(2R) (4R) Connected Mode Throughput
(Mbit/s)
UBB 6 (2R) 384/5 6x15 288/288 3 (2R) l 1.4 MHz: 504 450/225
Pe3 3 (4R) 12 l 3 MHz: 1080
l 5 MHz: 1800
l 10/15/20
MHz: 3600
NOTE
(1):
This specification can be provided only when the Standard Ratio parameter is set to
FDD_ENHANCE(FDD Enhance).
NOTE
(1)(2): This specification can be provided only when the Standard Ratio parameter is set to
FDD_ENHANCE(FDD Enhance).
NOTE
(1):
This specification can be provided only when Standard Ratio is set to NR_ENHANCE(NR
Enhance).
TRXs (4R) 6
HSDPA/HSUPA 192/192
UEs
Max UEs in l 1.4 MHz: 504 l 1.4 MHz: 504 l 1.4 MHz:
RRC Connected l 3 MHz: 1080 l 3 MHz: 1080 504
Mode l 3 MHz: 1080
l 5 MHz: 1800 l 5 MHz: 1800
l 10 MHz: 2520 l 10 MHz: 2520 l 5 MHz: 1800
l 10 MHz:
2520
LTE NB- Max Cells 3 (4R, 200 kHz) 3 (2R, 200 kHz) 3 (4R, 200 kHz)
IoT
Max UEs 635,000 635,000 635,000
Max UEs in 1800, which can 1800, which can 1800, which can
RRC Connected be shared with be shared with be shared with
Mode LTE FDD; ≤ 3600 LTE FDD; ≤ 3600 LTE FDD; ≤
in total in total 3600 in total
LTE NB- Max Cells 3 (2R, 400 kHz) 3 (4R, 400 kHz)
IoT
Max UEs 635,000 635,000
Type Specifications
Type Specifications
Item Specifications
Type Specifications
Environmental Specifications
The following table lists the environmental specifications of a BBU5900.
Item Specifications
Storage time It is recommended that the product be installed and put into use
within a year after being delivered. Otherwise, it may
malfunction.
Compliance Standards