SAUDI ARAMCO INSPECTION CHECKLIST
Concrete Sampling, Testing & Placement Inspection SAIC-Q-1060 29-Jun-17 CPP-CIVIL-
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR
LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.
SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?
SATIP-Q-002-01 3.4
SAUDI ARAMCO INSPECTION LEVEL
W
CONTRACTOR INSPECTION LEVEL
I
YES
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
A Receiving/Sampling/Testing Inspection
All ready-mix concrete are delivered to the site with a batch ticket listing
the following:
Name of the ready-mix company,
Location of Batch Plant
Serial number of the ticket, date, truck number
Name of purchaser
Name of the job and location,
Job Order (JO) Number for Project
Saudi Aramco mix design number 09-SAMSS-097
A1
Amount of concrete in cubic meters (or yards) Sec. 14.1
Time of loading, if wet mix
Reading of the revolution counter at the first addition of water
Type, brand & amount of cement, silica fume & admixture
Source and Total Amount of Mixing Water
Maximum Size of Aggregate
Mass of fine and course aggregate
Time Leaving Batch Plant
Signature or initials of producer's representative
Ready mix concrete delivered in trucks not having operable revolution 09-SAMSS-097
A2
counters shall be rejected. Sec. 11.1.2
No aluminum parts shall be placed in contact with concrete during mixing 09-SAMSS-097
A5
or delivery. Sec. 12
SAES-Q-001
Slump and cylinder test samples shall be taken from the end of the mixture
Sec. 5, 09-
A6 truck chute or at the discharge point of the concrete placement hose when
SAMSS-097 Sec.
concrete pumps are used.
7.2
Strength tests as well as slump, temperature, density and air content tests
SAES-Q-001 sec.
(when required by the specifications) shall be made with a frequency of not
5, 09-SAMSS-
A7 less than one test for each 115 m³. Each test shall be made from a
097
separate batch. On each day concrete is delivered, at least one strength
Sec. 17.5
test shall be made for each class of concrete.
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
Slump, air content, density and temperature tests shall be made at the
time of placement at the option of the inspector as often as necessary for
control checks.
SAES-Q-001 sec.
5. 09-
A8 Note: It is not the intention to give the inspector to right to require testing
SAMSS-097
for every truckload. Rather, additional testing shall be requested only if
there are indications that a concrete load was tempered (water was added
while concrete was in transit, or when there are indications that the mix is
exhibiting rapid drying).
The minimum required number of concrete test cylinders for strength tests
in accordance with ASTM C39/C39M shall be:
a) Test one set of laboratory-cured 09-SAMSS-097
A9
specimens at 7 days and one set of specimens at 28 days. Sec. 18.2
b) Test one set of field-cured specimens at 7 days and one set of
specimens at 28 days.
Equipment made of aluminum alloys shall not be used for pump lines, SAES-Q-001
B1
tremies or chutes used to discharge concrete from a truck mixer. Sec. 7.23.2
Fresh concrete are not deposited on concrete that has sufficiently SAES-Q-001
B5
hardened to cause formation of cold joints. (ACI 301-2010, Sec. 5.3.2.4) Sec. 3.2
Concrete that contains foreign material are not placed. (ACI 301-2010, SAES-Q-001
B6
Sec. 5.3.2.4) Sec. 3.2
SAES-Q-001
B7 Raking shall not be used for movement of concrete after placement.
Sec. 7.23.4
SAES-Q-001
B8 Vibrators shall not be used to move concrete inside forms.
Sec. 7.23.5
SAES-Q-001
B9 Retempering of concrete after placement is prohibited.
Sec. 7.23.6
Concrete shall not be dropped freely where reinforcing will cause SAES-Q-001
B10
segregation nor where it would fall freely for more than 1 meter. Sec. 7.23
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
The spacing of immersion vibrator insertions shall not exceed 1-1/2 times
SAES-Q-001
B14 the vibrator’s radius of action in the concrete being consolidated. (ACI 301-
Sec. 3.2
2010, Sec. 5.3.2.5)
SAES-Q-001
B15 Concrete shall be placed on a clean surface free of standing water.
Sec. 7.23.9
Precast concrete or mortar spacing blocks or bar supports are prohibited. SAES-Q-001
B16
(ACI 301-10 Sec 6.2.1.6) Sec. 7.23
Concrete paving shall have control joints or construction joints located at a SAES-Q-001
B18
maximum spacing of 6 meters on center in both directions. Sec. 7.20.5
Expansion joints shall be used in paving adjacent to all poured in place SAES-Q-001
B19
concrete members. Sec. 7.20.6
Paving or slab construction joints not specified on the IFC Drawings, shall SAES-Q-001
B20
be located at column centerlines and at intermediate intervals. Sec. 7.20.7
Joints not specified in the IFC Drawings shall be in accordance with ACI
SAES-Q-001
B22 301, Chapter 2, Section 2.2.2.5 and Chapter 5, Sections5.1.2.3a, 5.2.2.1
Sec. 7.20
and 5.3.2.6.
After concreting and before setting of concrete, the foundations and other
connection points (especially but not limited to anchor bolts) are checked 12-SAMSS-008,
B24
by surveyor to confirm their location, orientation, elevation and condition. Sec. IV
(PIP STS05130, Para. 6.2.10)
REMARKS:
REFERENCE DOCUMENTS:
1- SAES-Q-001 -- Criteria for Design and Construction of Concrete Structures, 07 January 2016
2- 09-SAMSS-097 -- Ready Mixed Portland Cement Concrete, 16 September 2015
3- 12-SAMSS-008-- Erection of Structural and Miscellaneous Steel, 25 Dec. 2014
Contractor / Third-Party Saudi Aramco
Construction Representative* PMT Representative
Work is Complete and Ready for Inspection: T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:
MR.USMAN
QC Inspector PID Representative
Performed Inspection Work / Rework May Proceed T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:
MR.USMAN
QC Supervisor Proponent and Others
Quality Record Approved: T&I Witnessed QC Record Reviewed Work Verified
Name, Organization,
Name, Sign and Date:
Initials and Date:
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
Name, Organization,
Name, Sign and Date:
Initials and Date: