Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Name
1. Fan 4. Fan Belt
2. Spacer 5. Water Pump ASM
3. Water Pump Pulley 6. Gasket
Removal
1. Drain the coolant.
2. Remove the four mounting bolts and then the fan
ASM and spacer, water pump pulley.
Cooling System 1B-9
Name Name
1. Fan 1. Water Pump
2. Spacer
3. Water Pump Pulley 5. Remove the gasket.
4. Bolt
3. (2) and (3) that tighten the setting plate and water Inspection
pump together. Loosen the adjusting bolts (1) in 1. Appearance check
the generator and remove the fan belt. • Check for cracks or damage in the pump body.
• Check for cracks and corrosion in the impeller.
• Check for water leakage from the seal unit.
• If you find abnormalities, replace with the water
pump ASM.
2. Bearing nut check
• Rotate the fan center while pushing it along the
radial direction. Confirm that there is no
abnormal noise and no excessive play.
• If you find abnormalities, replace with the water
pump ASM.
Name
1. Adjusting Bolt
2. Lock Nut
3. Bolt
Name
1. Fan ASM
2. Spacer
3. Water Pump Pulley
4. Bolt
7. Pour coolant.
Name
1. Adjusting Bolt
2. Lock Nut