Sei sulla pagina 1di 7

Pump Performance Datasheet

Customer : Quote number :


Customer enquiry : SPP Pumps Inc Pump Size : TD15F
Item number : 1500GPM@150PSI Stages :1
Usage - Tertiary : Based on curve number : TD15F-FMT-C2950 Rev 1G-A2
Quantity :1 Date last saved :
Operating Conditions Liquid
Flow, rated : 1,500.0 USgpm Liquid Type/ Application : Does not exist in KB (Liq-1Wat)
Differential Head (requested) : 150.0 psi Additional liquid description :
Suction pressure, rated / max : 1.00 / 1.00 psi.g Temperature, max : 30.00 deg C
NPSH available, rated : Ample Fluid density rated : 1.000 / 1.000 SG
Frequency : 60 Hz Viscosity, rated : 1.00 cP
NFPA Limits Performance
Flow, rated : 1,500.0 USgpm Speed, rated : 2950 rpm
Head, rated : 149.9 psi Impeller diameter, rated (approx.) : 12.56 in
Power, rated : 187 hp Impeller diameter, maximum : 12.80 in
NPSHr, rated : 3.30 psi Impeller diameter, minimum : 9.45 in
Efficiency, rated : 72 % Efficiency : 72 %
Flow at 150% : 2,280.0 USgpm NPSH required / margin required : 3.30 / 0.71 psi
Head at 150%, actual/limit : 123.0 psi Head, maximum, rated diameter : 191.8 psi
Efficiency at 150% : 78 % (approx.)
NPSHr at 150% flow : 5.47 psi Diameter ratio (rated / max) : 98.15 %
Power required at 150% flow : 210 hp Driver & Power Data (@Max density)
Peak power : 216 hp Power, hydraulic : 134 hp
Closed valve pressure : 192.8 psi.g Power, rated : 187 hp
140% Head at shutoff : 210.0 psi Power, maximum, rated diameter : 216 hp
65% Head at 150% flow : 97.50 psi Material
Cooling flow (2%) : 30.00 USgpm Material selected : CI / Br / CS
Pressure Data Selection status
Maximum working pressure : 192.8 psi.g FM/UL/cUL approved : FM/UL/cUL
Maximum allowable working pressure : 224.8 psi.g Near miss reasons :
Maximum allowable suction pressure : 74.98 psi.g
Hydrostatic test pressure : 289.2 psi.g
320
Power - hp

240
Power
160

80

250 100

225 90

200 80

175 12.56 in 70
Efficiency - %
Head - psi

150 60

125 Efficiency 50

100 40

75 30

50 20

25 10

0 0
NPSHr - psi

18
NPSHr
9

0
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000
Flow - USgpm
Pump Performance Datasheet
Customer : Quote number :
Customer enquiry : SPP Pumps Inc Pump Size : TD15F
Item number : 1500GPM@150PSI Stages :1
Usage - Tertiary : Based on curve number : TD15F-FMT-C2950 Rev 1G-A2
Quantity :1 Date last saved :
Operating Conditions Liquid
Flow, rated : 1,500.0 USgpm Liquid Type/ Application : Does not exist in KB (Liq-1Wat)
Differential Head (requested) : 150.0 psi Additional liquid description :
Suction pressure, rated / max : 1.00 / 1.00 psi.g Temperature, max : 30.00 deg C
NPSH available, rated : Ample Fluid density rated : 1.000 / 1.000 SG
Frequency : 60 Hz Viscosity, rated : 1.00 cP
Flow Head Pump Efficiency Power Required NPSH required
(USgpm) (psi) (%) (hp) (psi)
0.00 191.8 0 119 -
451.5 178.1 34 138 -
903.0 166.7 55 158 0.42
1,354.4 155.0 68 180 2.71
1,805.9 141.2 75 198 4.10
2,257.4 124.0 78 210 5.40
2,708.9 102.8 75 216 7.13
3,160.4 77.86 67 214 9.75
3,611.9 49.80 51 206 14.29
Manual No/Rev Operators Instructions for Horizontal
W12-007E / 7 Thrustream Fire Pumps

8. Pump Details:
8.1 Typical Pump Cross Section Drawing – Modules 1 and 2 (Double Entry Impeller)
This section applies to the following pump types:
Module 1 TB08D & E
Module 1 Special TC12F & G - TD10E
Module 2 TB10D & E - TB12D, E & F - TB15E & F - TD12F - TD15F - TE10A - TE15D & E and TD25 A

Module 2 Special TE10D & TE12E (with stuffing box variation)

Our policy is one of continuous improvement and we reserve the right to alter specifications at any time
Page 20 of 28
Operators Instructions for Horizontal Manual No/Rev
Thrustream Fire Pumps W12-007E / 7

8.2 Typical Pump Cross Section Drawing – Module 2 Special (Single Entry Impeller)
This section applies to the following pump type:
Module 2 Special (Single Entry Impeller) TE08D (with stuffing box packing variation)

Our policy is one of continuous improvement and we reserve the right to alter specifications at any time
Page 21 of 28
Manual No/Rev Operators Instructions for Horizontal
W12-007E / 7 Thrustream Fire Pumps

8.3 Typical Pump Cross Section Drawing – Modules 3 & 3 Special (Double Entry Impeller)
This section applies to the following pump types:
Module 3 TE20A & D - TE25A & D - TF20A, D, E, F & G
Module 3 Special TD20D & E

Module 3 Special TF15E (with stuffing box packing variation)

Our policy is one of continuous improvement and we reserve the right to alter specifications at any time
Page 22 of 28
Operators Instructions for Horizontal Manual No/Rev
Thrustream Fire Pumps W12-007E / 7

8.4 Typical Pump Cross Section Drawing – Module 1T (Two Stage Fire Pump)
This section applies to the following pump types:
Module 1T TX12D – TY12D - TX15E & F - TY15E

Our policy is one of continuous improvement and we reserve the right to alter specifications at any time
Page 23 of 28
Manual No/Rev Operators Instructions for Horizontal
W12-007E / 7 Thrustream Fire Pumps

8.5 Parts Identification List:

Note: Pump construction may vary slightly between the different pump sizes within each module, it is
important to refer to the specific pump section drawing and to quote the pump serial number when
ordering parts to ensure that the correct part is supplied in the original material of construction.

Item Description Qty Item Description Qty


A1 Casing Top Half 1 73 Eyebolt 1
B1 Casing Bottom Half 1 75 Bearing Retaining Nut 1
1A Casing Stud Varies 75F Bearing Lock Washer 1
1B Casing Stud 4 77 Shoulder Ring 2
1C Casing Dowel 2 79 Spacer Ring 1
1CF Hexagon Nut Full Dowel 2 105 Grease Nipple 2
1CG Plain Washer Dowel 2 A106 Elbow 90deg. 2
1D Dowel Pin - Insert 2 B106 Stud Coupling 4
1F Hexagon Nut Full Casing Varies C106 Tubular Piece 2
1L Casing Gauge Plug (Not Shown) 2 D106 Stud Coupling 2
1M Casing Drain Plug (Not Shown) 2 A107 Pipe 2
1N Casing Priming Plug (Not Shown) 2 B107 Pipe 2
1U Casing Gasket 1 116 Key Impeller 1
21 Impeller 1 118 Key Coupling 1
22 Impeller Wear Ring (Where fitted) 2 308(Y) Auto Air Release Valve 1
22A Setscrew Impeller Wear Ring 4 Different Parts for two stage pumps
23 Case Wear Ring 2 8 Interstage Plate (Two Stage) 1
23A Dowel Case Wear Ring 2 8A Dowel 1
41 Insert 2 8R O Ring – Interstage Plate 1
41A Stud – Insert 8 17 Impeller Spacer (Two Stage) 1
41C Stud – Gland 4 17R O Ring – Impeller Spacer 2
41F Hexagon Nut Full – Support Frame 8 A21 Impeller (CW Second Stage) 1
41G Hexagon Nut Full – Gland 4 B21 Impeller (CCW First Stage) 1
41L Plug – Insert 2 24 Interstage Neck Bush 1
24A Socket Set Screw – Neck Bush 2
41R O Ring - Insert 2
45 Spacer Ring 2
41X Dowel Pin – Insert 2
46 Lantern Ring 4
46 Lantern Ring 2
47S O Ring – Sleeve - Inner 2
A47 Sleeve - Locked 1
A53 Insert 1
B47 Sleeve – Free 1
B53 Insert 1
47R O Ring – Sleeve / Nut 2
62Y Cover Plate 1
50 Gland 2
62YA Hexagon Headed Screw 4
51 Packing 8
64 Bearing Cover 2
53 Spacer Ring (Stuffing Box) 2
64A Hexagon Headed Screw 8
53A Socket Capscrew 8
64R Oil Seal 2
53F Spring Washer 8
64S Oil Seal 1
53R O Ring Insert 2 72 Liquid Thrower 2
61 Support Frame 2 72A Socket Set Screw 2
61A Hexagon Headed Screw 8 308X Adaptor 1
61F Plain Washer 8
A62 Bearing Housing Non-drive End 1 Replacement parts should be obtained from
A62L Plug Bearing Housing N.D.E 1 SPP Pumps Ltd. Spares Department; use of
parts from unapproved suppliers will invalidate
B62 Bearing Housing Drive End 1 the pump warranty. When ordering spare parts
66 Bearing Non-drive End 1 please quote the pump serial number from the
67 Bearing Drive End 1 pump identification plate.
71 Pump Shaft 1
72 V ring Seal 2
Our policy is one of continuous improvement and we reserve the right to alter specifications at any time
Page 24 of 28

Potrebbero piacerti anche