Engineering Data

Rev 9 - 21/02/11

Engineering Data F4HS - Air Cooled

Pressure Dew Point (°C) 3 5 7


Airflow Capacity (m³/h FAD 20°C) 24,0 26,8 30,0
Air Pressure Drop (bar) 0,015 0,018 0,022
Air Temperature at Dryer Outlet (°C) 17,0 18,0 19,0
Compressor Absorbed Power (kW) 0,13 0,13 0,14
Condenser Heat Rejected (kW) 0,4 0,4 0,4
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 90 / 1
Maximum Operating Pressure (bar g) 16
Sound Pressure Level (dBA) (1 m free field )* 50
Refrigerant Type R134a
Fridge Compressor Type / n° Hermetic Pistons / 1
Refrigerant Quantity (kg) 0,17
Capacity Control Automatic Expansion Valve
Expansion System Automatic Expansion Valve
Air-to-air Heat Exchanger Aluminium Plate in Vessel
Air-to-refrigerant Heat Exchanger Aluminium Plate in Vessel
Number of Heat Exchangers 1
Separator Type Demister
Standard Drain Type Timed Drain
PIPING CONNECTIONS
Air Inlet / Outlet ½” BSP - F
Condensate Drain Outlet ½” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 450
Height (mm) 430
Depth (mm) 210
Weight (kg) 19
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 230V / 1 ph / 50Hz
F.L.A. Current (Amps) 1,41
Total Installed Power (kW) 0,26
Control Type Electromechanical
Electrical Protection Class (Std.) IP 20
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*Sound pressure level in accordance with ISO 3746 Max / Min Ambient Temperature (°C): 50 / 5
Max / Min Air Inlet Temperature (°C): 65 / 5
Engineering Data
Rev 9 - 21/02/11

Engineering Data F6HS - Air Cooled

Pressure Dew Point (°C) 3 5 7


Airflow Capacity (m³/h FAD 20°C) 36,0 39,9 44,4
Air Pressure Drop (bar) 0,031 0,038 0,046
Air Temperature at Dryer Outlet (°C) 17,6 18,6 19,5
Compressor Absorbed Power (kW) 0,17 0,18 0,19
Condenser Heat Rejected (kW) 0,5 0,5 0,6
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 90 / 1
Maximum Operating Pressure (bar g) 16
Sound Pressure Level (dBA) (1 m free field )* 50
Refrigerant Type R134a
Fridge Compressor Type / n° Hermetic Pistons / 1
Refrigerant Quantity (kg) 0,17
Capacity Control Automatic Expansion Valve
Expansion System Automatic Expansion Valve
Air-to-air Heat Exchanger Aluminium Plate in Vessel
Air-to-refrigerant Heat Exchanger Aluminium Plate in Vessel
Number of Heat Exchangers 1
Separator Type Demister
Standard Drain Type Timed Drain
PIPING CONNECTIONS
Air Inlet / Outlet ½” BSP - F
Condensate Drain Outlet ½” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 450
Height (mm) 430
Depth (mm) 210
Weight (kg) 19
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 230V / 1 ph / 50Hz
F.L.A. Current (Amps) 1,41
Total Installed Power (kW) 0,26
Control Type Electromechanical
Electrical Protection Class (Std.) IP 20
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*Sound pressure level in accordance with ISO 3746 Max / Min Ambient Temperature (°C): 50 / 5
Max / Min Air Inlet Temperature (°C): 65 / 5
Engineering Data
Rev 9 - 21/02/11

Engineering Data F9HS - Air Cooled

Pressure Dew Point (°C) 3 5 7


Airflow Capacity (m³/h FAD 20°C) 54,0 60,0 66,7
Air Pressure Drop (bar) 0,032 0,039 0,048
Air Temperature at Dryer Outlet (°C) 21,9 22,5 23,2
Compressor Absorbed Power (kW) 0,25 0,26 0,27
Condenser Heat Rejected (kW) 0,7 0,7 0,7
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 220 / 1
Maximum Operating Pressure (bar g) 16
Sound Pressure Level (dBA) (1 m free field )* 55
Refrigerant Type R134a
Fridge Compressor Type / n° Hermetic Pistons / 1
Refrigerant Quantity (kg) 0,2
Capacity Control Automatic Expansion Valve
Expansion System Automatic Expansion Valve
Air-to-air Heat Exchanger Aluminium Plate in Vessel
Air-to-refrigerant Heat Exchanger Aluminium Plate in Vessel
Number of Heat Exchangers 1
Separator Type Demister
Standard Drain Type Timed Drain
PIPING CONNECTIONS
Air Inlet / Outlet ½” BSP - F
Condensate Drain Outlet ½” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 500
Height (mm) 505
Depth (mm) 210
Weight (kg) 23,5
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 230V / 1 ph / 50Hz
F.L.A. Current (Amps) 1,86
Total Installed Power (kW) 0,35
Control Type Electromechanical
Electrical Protection Class (Std.) IP 20
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*Sound pressure level in accordance with ISO 3746 Max / Min Ambient Temperature (°C): 50 / 5
Max / Min Air Inlet Temperature (°C): 65 / 5
Engineering Data
Rev 9 - 21/02/11

Engineering Data F12HS - Air Cooled

Pressure Dew Point (°C) 3 5 7


Airflow Capacity (m³/h FAD 20°C) 72,0 79,8 88,6
Air Pressure Drop (bar) 0,055 0,066 0,081
Air Temperature at Dryer Outlet (°C) 22,1 22,8 23,4
Compressor Absorbed Power (kW) 0,25 0,26 0,28
Condenser Heat Rejected (kW) 0,8 0,8 0,9
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 220 / 1
Maximum Operating Pressure (bar g) 16
Sound Pressure Level (dBA) (1 m free field )* 55
Refrigerant Type R134a
Fridge Compressor Type / n° Hermetic Pistons / 1
Refrigerant Quantity (kg) 0,2
Capacity Control Automatic Expansion Valve
Expansion System Automatic Expansion Valve
Air-to-air Heat Exchanger Aluminium Plate in Vessel
Air-to-refrigerant Heat Exchanger Aluminium Plate in Vessel
Number of Heat Exchangers 1
Separator Type Demister
Standard Drain Type Timed Drain
PIPING CONNECTIONS
Air Inlet / Outlet ½” BSP - F
Condensate Drain Outlet ½” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 500
Height (mm) 505
Depth (mm) 210
Weight (kg) 23,5
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 230V / 1 ph / 50Hz
F.L.A. Current (Amps) 1,86
Total Installed Power (kW) 0,35
Control Type Electromechanical
Electrical Protection Class (Std.) IP 20
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*Sound pressure level in accordance with ISO 3746 Max / Min Ambient Temperature (°C): 50 / 5
Max / Min Air Inlet Temperature (°C): 65 / 5
Engineering Data
Rev 9 - 21/02/11

Engineering Data F18HS - Air Cooled

Pressure Dew Point (°C) 3 5 7


Airflow Capacity (m³/h FAD 20°C) 108,0 120,0 133,2
Air Pressure Drop (bar) 0,10 0,12 0,15
Air Temperature at Dryer Outlet (°C) 19,9 20,7 21,5
Compressor Absorbed Power (kW) 0,49 0,52 0,55
Condenser Heat Rejected (kW) 1,4 1,5 1,6
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 270 / 1
Maximum Operating Pressure (bar g) 16
Sound Pressure Level (dBA) (1 m free field )* 55
Refrigerant Type R134a
Fridge Compressor Type / n° Hermetic Pistons / 1
Refrigerant Quantity (kg) 0,25
Capacity Control Automatic Expansion Valve
Expansion System Automatic Expansion Valve
Air-to-air Heat Exchanger Aluminium Plate in Vessel
Air-to-refrigerant Heat Exchanger Aluminium Plate in Vessel
Number of Heat Exchangers 1
Separator Type Demister
Standard Drain Type Timed Drain
PIPING CONNECTIONS
Air Inlet / Outlet ¾” BSP - F
Condensate Drain Outlet ½” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 520
Height (mm) 565
Depth (mm) 225
Weight (kg) 26,5
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 230V / 1 ph / 50Hz
F.L.A. Current (Amps) 3,43
Total Installed Power (kW) 0,59
Control Type Electromechanical
Electrical Protection Class (Std.) IP 20
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*Sound pressure level in accordance with ISO 3746 Max / Min Ambient Temperature (°C): 50 / 5
Max / Min Air Inlet Temperature (°C): 65 / 5
Engineering Data
Rev 9 - 21/02/11

Engineering Data F24HS - Air Cooled

Pressure Dew Point (°C) 3 5 7


Airflow Capacity (m³/h FAD 20°C) 144,0 159,6 176,4
Air Pressure Drop (bar) 0,17 0,21 0,25
Air Temperature at Dryer Outlet (°C) 20,9 21,6 22,4
Compressor Absorbed Power (kW) 0,57 0,60 0,63
Condenser Heat Rejected (kW) 1,7 1,8 1,9
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 380 / 1
Maximum Operating Pressure (bar g) 16
Sound Pressure Level (dBA) (1 m free field )* 55
Refrigerant Type R134a
Fridge Compressor Type / n° Hermetic Pistons / 1
Refrigerant Quantity (kg) 0,30
Capacity Control Automatic Expansion Valve
Expansion System Automatic Expansion Valve
Air-to-air Heat Exchanger Aluminium Plate in Vessel
Air-to-refrigerant Heat Exchanger Aluminium Plate in Vessel
Number of Heat Exchangers 1
Separator Type Demister
Standard Drain Type Timed Drain
PIPING CONNECTIONS
Air Inlet / Outlet ¾” BSP - F
Condensate Drain Outlet ½” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 520
Height (mm) 565
Depth (mm) 225
Weight (kg) 31
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 230V / 1 ph / 50Hz
F.L.A. Current (Amps) 4,39
Total Installed Power (kW) 0,76
Control Type Electromechanical
Electrical Protection Class (Std.) IP 20
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*Sound pressure level in accordance with ISO 3746 Max / Min Ambient Temperature (°C): 50 / 5
Max / Min Air Inlet Temperature (°C): 65 / 5
Engineering Data
Rev 9 - 21/02/11

Engineering Data F30HS - Air Cooled

Pressure Dew Point (°C) 3 5 7


Airflow Capacity (m³/h FAD 20°C) 180,0 200,4 223,8
Air Pressure Drop (bar) 0,26 0,32 0,39
Air Temperature at Dryer Outlet (°C) 21,5 22,1 22,8
Compressor Absorbed Power (kW) 0,78 0,82 0,86
Condenser Heat Rejected (kW) 2,2 2,3 2,5
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 550 / 1
Maximum Operating Pressure (bar g) 16
Sound Pressure Level (dBA) (1 m free field )* 55
Refrigerant Type R134a
Fridge Compressor Type / n° Hermetic Pistons / 1
Refrigerant Quantity (kg) 0,36
Capacity Control Automatic Expansion Valve
Expansion System Automatic Expansion Valve
Air-to-air Heat Exchanger Aluminium Plate in Vessel
Air-to-refrigerant Heat Exchanger Aluminium Plate in Vessel
Number of Heat Exchangers 1
Separator Type Demister
Standard Drain Type Timed Drain
PIPING CONNECTIONS
Air Inlet / Outlet ¾” BSP - F
Condensate Drain Outlet ½” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 520
Height (mm) 565
Depth (mm) 225
Weight (kg) 35
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 230V / 1 ph / 50Hz
F.L.A. Current (Amps) 5,03
Total Installed Power (kW) 0,92
Control Type Electromechanical
Electrical Protection Class (Std.) IP 20
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*Sound pressure level in accordance with ISO 3746 Max / Min Ambient Temperature (°C): 50 / 5
Max / Min Air Inlet Temperature (°C): 65 / 5
Engineering Data
Rev 9 - 21/02/11

Engineering Data F39HS - Air Cooled

Pressure Dew Point (°C) 3 5 7


Airflow Capacity (m³/h FAD 20°C) 240,0 267,0 298,2
Air Pressure Drop (bar) 0,14 0,19 0,23
Air Temperature at Dryer Outlet (°C) 25,0 25,4 25,9
Compressor Absorbed Power (kW) 0,71 0,75 0,79
Condenser Heat Rejected (kW) 2,3 2,5 2,6
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 540 / 2
Maximum Operating Pressure (bar g) 16
Sound Pressure Level (dBA) (1 m free field )* 55
Refrigerant Type R134a
Fridge Compressor Type / n° Hermetic Pistons / 1
Refrigerant Quantity (kg) 0,55
Capacity Control Automatic Expansion Valve
Expansion System Automatic Expansion Valve
Air-to-air Heat Exchanger Aluminium Plate in Vessel
Air-to-refrigerant Heat Exchanger Aluminium Plate in Vessel
Number of Heat Exchangers 1
Separator Type Demister
Standard Drain Type Timed Drain
PIPING CONNECTIONS
Air Inlet / Outlet 1+½”” BSP - F
Condensate Drain Outlet ½” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 555
Height (mm) 600
Depth (mm) 425
Weight (kg) 52
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 230V / 1 ph / 50Hz
F.L.A. Current (Amps) 5,26
Total Installed Power (kW) 0,95
Control Type Electromechanical
Electrical Protection Class (Std.) IP 20
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*Sound pressure level in accordance with ISO 3746 Max / Min Ambient Temperature (°C): 50 / 5
Max / Min Air Inlet Temperature (°C): 65 / 5
Engineering Data
Rev 9 - 21/02/11

Engineering Data F49HS - Air Cooled

Pressure Dew Point (°C) 3 5 7


Airflow Capacity (m³/h FAD 20°C) 300,0 335,4 374,4
Air Pressure Drop (bar) 0,23 0,28 0,35
Air Temperature at Dryer Outlet (°C) 24,0 24,5 25,1
Compressor Absorbed Power (kW) 0,85 0,89 0,93
Condenser Heat Rejected (kW) 3,0 3,2 3,4
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 760 / 2
Maximum Operating Pressure (bar g) 16
Sound Pressure Level (dBA) (1 m free field )* 55
Refrigerant Type R134a
Fridge Compressor Type / n° Hermetic Pistons / 1
Refrigerant Quantity (kg) 0,82
Capacity Control Hot Gas by-pass
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium Plate in Vessel
Air-to-refrigerant Heat Exchanger Aluminium Plate in Vessel
Number of Heat Exchangers 1
Separator Type Demister
Standard Drain Type Timed Drain
PIPING CONNECTIONS
Air Inlet / Outlet 1+½”” BSP - F
Condensate Drain Outlet ½” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 555
Height (mm) 600
Depth (mm) 425
Weight (kg) 58
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 230V / 1 ph / 50Hz
F.L.A. Current (Amps) 6,36
Total Installed Power (kW) 1,10
Control Type Electromechanical
Electrical Protection Class (Std.) IP 20
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*Sound pressure level in accordance with ISO 3746 Max / Min Ambient Temperature (°C): 50 / 5
Max / Min Air Inlet Temperature (°C): 65 / 5
Engineering Data
Rev 9 - 21/02/11

Engineering Data F59HS - Air Cooled

Pressure Dew Point (°C) 3 5 7


Airflow Capacity (m³/h FAD 20°C) 360,0 396,0 436,8
Air Pressure Drop (bar) 0,32 0,38 0,46
Air Temperature at Dryer Outlet (°C) 24,3 24,9 25,4
Compressor Absorbed Power (kW) 1,05 1,10 1,15
Condenser Heat Rejected (kW) 3,5 3,7 3,9
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 1100 / 2
Maximum Operating Pressure (bar g) 16
Sound Pressure Level (dBA) (1 m free field )* 55
Refrigerant Type R134a
Fridge Compressor Type / n° Hermetic Pistons / 1
Refrigerant Quantity (kg) 0,88
Capacity Control Hot Gas by-pass
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium Plate in Vessel
Air-to-refrigerant Heat Exchanger Aluminium Plate in Vessel
Number of Heat Exchangers 1
Separator Type Demister
Standard Drain Type Timed Drain
PIPING CONNECTIONS
Air Inlet / Outlet 1+½”” BSP - F
Condensate Drain Outlet ½” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 555
Height (mm) 600
Depth (mm) 425
Weight (kg) 60
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 230V / 1 ph / 50Hz
F.L.A. Current (Amps) 6,76
Total Installed Power (kW) 1,37
Control Type Electromechanical
Electrical Protection Class (Std.) IP 20
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*Sound pressure level in accordance with ISO 3746 Max / Min Ambient Temperature (°C): 50 / 5
Max / Min Air Inlet Temperature (°C): 65 / 5