Sei sulla pagina 1di 1

MT - 147

[3] Checking the LED Lighting Status [4] Measuring the Motor Resistance Value
(1) Remove the lower light protect plate. (1) Power OFF the machine.
(2) Turn OFF the high-voltage switch of the SCN12A board. (2) Remove the covers to gain access to the motor.
(3) Start the M-Utility. (3) Measure the winding resistance of the motor.
(4) Perform the procedures described in [2] to drive the relevant motor, and verify the LED Check the connector pin numbers by way of cable colors, and make sure that the winding
lighting status. resistance value of the motor is held within its reference levels.

Location I/O No. Monitoring description LED ON OFF ● Terminal numbers and locations
Latch
MA1 Monitors the suction cup driving motor control signal. Drive Stop Terminal No. Motor cable color

6 5 4 1 Red
DRV12A board MB1 Monitors the IP transport motor control signal. Drive Stop 3 2 1 2 Black
FRMT0433.EPS 3 Yellow
TR6H2010.EPS
4 Blue
(5) Type in [2][ENT] to stop the motor, and verify the LED lighting status. 5 White

6 Orange
TR6H2551.EPS

● Winding resistance value of the motor (common to MA and MB1)

Measurement position Reference


resistance value
1 (red) 2 (black)
3 (yellow) 2 (black)
0.8 – 1.3Ω
4 (blue) 5 (white)
6 (orange) 5 (white)
TR6H2552.EPS

010-051-06 CR-IR346RU Service Manual [12.1] MT - 147